Cone Beam Reconstruction Jiang Hsieh, Ph.D.



Similar documents
CT Image Reconstruction. Terry Peters Robarts Research Institute London Canada

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Purchasing a cardiac CT scanner: What the radiologist needs to know

Introduction to Medical Imaging. Lecture 11: Cone-Beam CT Theory. Introduction. Available cone-beam reconstruction methods: Our discussion:

How To Improve Your Ct Image Quality

MEDICAL IMAGING 2nd Part Computed Tomography

Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

Image Analysis for Volumetric Industrial Inspection and Interaction

Fundamentals of Cone-Beam CT Imaging

A Grangeat-type half-scan algorithm for cone-beam CT

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data

Medical Image Processing on the GPU. Past, Present and Future. Anders Eklund, PhD Virginia Tech Carilion Research Institute

IMAGE PROCESSING AND DATA ANALYSIS IN COMPUTED TOMOGRAPHY

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

The effect of pitch in multislice spiral/helical CT

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

An iterative approach to the beam hardening correction in cone beam CT

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Low-dose CT for Pulmonary Embolism

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1

Introduction to the Monte Carlo method

A Three-Dimensional Correlation Method for Registration of Medical Images in Radiology

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

Tumor. An Brief Introduction to 4D CT Scanning. Outline. Three Types of Motion Artifacts. CT Artifacts in Free Breathing 3D Scan

State-of-the-Art Technology in Cardiac CT

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.

Auto-Tuning Using Fourier Coefficients

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Geometry: Unit 1 Vocabulary TERM DEFINITION GEOMETRIC FIGURE. Cannot be defined by using other figures.

Lecture L6 - Intrinsic Coordinates

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Computerized Tomography, X-rays, and the Radon Transform

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

SITE IMAGING MANUAL ACRIN 6698

Algebra Academic Content Standards Grade Eight and Grade Nine Ohio. Grade Eight. Number, Number Sense and Operations Standard

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

Magnetic Field of a Circular Coil Lab 12

Data. microcat +SPECT

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

Lecture 14. Point Spread Function (PSF)

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

Aliasing, Image Sampling and Reconstruction

SIGNAL PROCESSING & SIMULATION NEWSLETTER

Lecture L5 - Other Coordinate Systems

Experiment #1, Analyze Data using Excel, Calculator and Graphs.

SOFTWARE FOR GENERATION OF SPECTRUM COMPATIBLE TIME HISTORY

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG All rights reserved

Measuring Line Edge Roughness: Fluctuations in Uncertainty

Synthetic Sensing: Proximity / Distance Sensors

Development of SCENARIA New Version Software MEDIX VOL. 62 P.32 P.35

Automated Pose Determination for Unrestrained, Non-anesthetized Small Animal Micro-SPECT and Micro-CT Imaging

Physics 235 Chapter 1. Chapter 1 Matrices, Vectors, and Vector Calculus

Pre-Algebra Academic Content Standards Grade Eight Ohio. Number, Number Sense and Operations Standard. Number and Number Systems

DICOM Correction Item

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

Multi-slice Helical CT Scanning of the Chest

Solving Simultaneous Equations and Matrices

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

Computed Tomography Instrumentation. Ian A. Cunningham. Data-Acquisition Geometries. Ian A. Cunningham

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Common Core Unit Summary Grades 6 to 8

X-ray thin-film measurement techniques

Physics testing of image detectors

In mathematics, there are four attainment targets: using and applying mathematics; number and algebra; shape, space and measures, and handling data.

Development of High Speed Oblique X-ray CT System for Printed Circuit Board

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

Development and quantitative assessment of a beam hardening correction model for preclinical micro-ct

Thnkwell s Homeschool Precalculus Course Lesson Plan: 36 weeks

Number Sense and Operations

Acknowledgement. Diagnostic X-Ray Shielding. Nomenclature for Radiation Design Criteria. Shielding Design Goal (Air Kerma):

Three Dimensional Ultrasound Imaging

Essential Mathematics for Computer Graphics fast

Classification of Fingerprints. Sarat C. Dass Department of Statistics & Probability

The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved.

3D Modelling and Volume Rotation of 2D Medical Images

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Curriculum Map by Block Geometry Mapping for Math Block Testing August 20 to August 24 Review concepts from previous grades.

Super-Resolution Reconstruction in MRI: Better Images Faster?

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

Prentice Hall Algebra Correlated to: Colorado P-12 Academic Standards for High School Mathematics, Adopted 12/2009

Solutions to Exercises, Section 5.1

Transcription:

Cone Beam Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1

Image Generation Reconstruction of images from projections. textbook reconstruction advanced acquisition (helical, multi-slice) advanced application (cardiac, perfusion) Formulation of 2D images to 3D volume. reconstruction Presentation 2

Textbook Reconstruction The mathematical foundation of CT can be traced back to 1917 to Radon. The algorithms can be classified into two classes: analytical and iterative. Some of the commonly used reconstruction formula was developed in the late 70s and early 80s. With the introduction of multi-slice helical CT, new cone beam reconstruction algorithms are developed. 3

CT Data Measurement -Under Ideal Conditions x-ray attenuation follows Beer s law. I o e µ x µ x µ 1 e 2 e n x I o µ I µ x o I = I e x o µ 1 µ 2 µ 3 µ 4 µ n ( µ + µ + + µ ) x x = I e 1 2 o n x-ray tube detector P x 0, I = ln = µ ( x) dx Io 4

Ideal Projections The measured data are not line integrals of attenuation coefficients of the object. beam hardening scattered radiation detector and data acquisition non-linearity patient motion others The data need to be calibrated prior to the tomographic reconstruction to obtain artifact-free free images. 5

Sampling Geometries The sampling geometry of CT scanners can be described three configurations. Due to time constraints, we will not conduct in-depth discussions on each geometry. detector detector detector source source source parallel beam fan beam cone beam 6

p x) = f ( x, y) dy Fourier Slice Theorem (Central Slice Theorem) i2πux ( P( u) = f ( x, y) e dxdy P( u) i2πux = f ( x, y) e dxdy 4000 1000 1000 2000 FT 500 = 500 0 1 255 PROJECTION 0 1 255 0 1 255 v=0 2D FT f ( x, y) F( u, v) = f ( x, y) e i2π ( ux+ vy) dxdy 7

Fourier Slice Theorem (central slice theorem) Fourier transform of projections at different angles fill up the Fourier space. Inverse Fourier transform recovers the original object. FFT 2D FFT 8

Implementation Difficulty Due to sampling pattern, direct implementation of the Fourier slice theorem is difficult. Cartesian grid sample location (Polar grid) 9

Filtered Backprojection The filtered backprojection formula can be derived from the Fourier transform pair, coordinate transformation, and the Fourier slice theory: backprojection pre-processed processed data f ( x, y) = π 0 P θ j πωt ( u)ω e 2 dωdθ filter the data backprojection filtering parallel beam reconstruction 10

Filter Implementation The filter as specified does not exist. k( t) = ω e ω j2 πω t d The filter needs to be band-limited: k( t) = W W ω e j2πωt dω K(ω) -w w ω 11

Filtered Backprojection -an intuitive explanation Filtered backprojection uses weighting function to approximate ideal condition. weighting function ideal frequency data from one projection actual frequency data from one projection weighting function for approximation 12

Filtering Consider an example of reconstructing a phantom object of two rods. Object Original Sinogram Filtered Sinogram views single projection detector sample 13

Backprojection Backprojection is performed by painting the intensity of the entire ray path with the filtered sample. filtered projection 14

Backprojection 0 o -30 o 0 o -60 o 0 o -90 o 0 o -120 o 0 o -150 o 0 o -180 o 15

Fan Beam Reconstruction Each ray in a fan beam can be specified by β and γ. Reconstruction process is similar to parallel reconstruction except additional apodization step and weighting in the backprojection. y β γ x pre-processed processed data Apodizaton filter the data backprojection fan beam geometry fan beam reconstruction 16

Equiangular Fan Beam Reconstruction f ( x, y ) = 2π 0 L 2 dβ γ m p γ ( γ, β ) h( γ ' γ ) D m cos γdγ The projection is first multiplied by the cosine of the detector angle. In the backprojection process, the filtered sample is scaled by the distance to the source. 17

Fan Beam Reconstruction Alternatively, the fan beam data can be converted to a set of parallel samples. Parallel reconstruction algorithms can be used for image formation. projection angle, β β=β 0 γ parallel samples detector angle, γ 18

Helical Scanning In helical scanning, the patient is translated at a constant speed while the gantry rotates. Helical pitch: h = q d distance gantry travel in one rotation collimator aperture q 19

Helical Scanning Advantages of helical scanning nearly 100% duty cycle (no inter- scan delay) improved contrast on small object (reconstruction at any z location) improved 3D images (overlapped reconstruction) z 20

Helical Scanning The helical data collection is inherently inconsistent. If proper correction is not rendered, image artifact will result. reconstructed helical scan without correction 21

Helical Reconstruction The plane of reconstruction is typically at the mid-point between the start and end planes. Interpolation is performed to estimate a set of projections at the plane of reconstruction. start of data set plane data sampling helix end of data set plane plane of reconstruction 22

Helical Reconstruction -360 o interpolation Samples at the plane-of of-reconstruction is estimated using two projections that are 360 o apart. p' ( γ, β ) = wp( γ, β ) + (1 w) p( γ, β + 2π ) where w = q q x x q data sampling helix p(γ,β) p (γ,β γ,β) p(γ,β+2π) 23

Helical Reconstruction -180 o interpolation In fan beam, each ray path is sampled by two conjugate samples that are related by: γ ' = γ β ' = β + π + 2γ For helical scan, these two samples are taken at different z location because of the table motion. 24

Helical Reconstruction -180 o interpolation Linear interpolation is used to estimate the projection samples at the plane of reconstruction. Because samples are taken at different view angles, the weights are γ and β dependent. wp( γ, β) + (1 w) p( γ, β + π 2γ ) plane of reconstruction p n (-γ,β+π 2γ) p k (γ,β) z-axis 25

Artifact Suppression Helical reconstruction algorithm effectively suppresses helical artifacts. without helical correction with helical correction 26

Multi-slice CT Multi-slice CT contains multiple detector rows. For each gantry rotation, multiple slices of projections are acquired. Similar to the single slice configuration, the scan can be taken in either the step-and and-shoot mode or helical mode. x-ray source detector 27

Advantages of Multi-slice Large coverage and faster scan speed Better contrast utilization Less patient motion artifacts Isotropic spatial resolution 28

Cone Beam Reconstruction FDK Algorithm Each ray in a cone beam can be specified by β, γ, and α. FDK algorithm was derived from fan-beam algorithm by studying the impact of cone angle to the rotation angle. z pre-processed processed data y weighting γ α β x x filter the data along row 3D backprojection fan beam reconstruction 29

Cone Beam Artifact center slice z edge slice multi-slice 30

Multi-slice Helical When acquiring data in a helical mode, the N detector rows form N interweaving helixes. Because multiple detector rows are used in the data acquisition, the acquisition speed is typically higher. h = q d distance gantry travel in one rotation collimator aperture plane-of-reconstruction d multi-slice 31

Cone Beam Helical Reconstruction Exact algorithms produce mathematically exact solutions when input projections are perfect. Katsevich Grangeat Rebin PHI FBP PHI Approximate algorithms, although non-exact, generate clinically accurate images. FDK-type N-PI CB-virtual circle Tilted Plane ZB 32

Cone Beam Algorithm small cone angle From a computational point of view, 3D backprojection is more expensive than 2D backprojection. To overcome the discrepancy, tilted planes are defined as the plane of reconstruction so that 2D reconstruction algorithm can still be used. interpolated sample plane of reconstruction z source helix tilted plane conventional POR 33

Tilted Plane Reconstruction For small cone angles, the flat plane and source helix match quite well. When the same weighting function is used, reconstructions with the tilted plane produces better image quality than the conventional reconstruction plane with 2D backprojection. conventional plane tilted plane 34

Cone Beam Reconstruction moderate cone angle For larger cone angles, tilted plane reconstruction is no longer sufficient, due to the larger difference between the flat plane and the curved helix. FDK-type algorithm with appropriate weighting is often used. z z helical path tilted plane multi-slice conventional POR 35

FDK-type Algorithm FDK-type algorithm can be combined with different weighting functions to optimize its performance in different performance parameters. Cone beam artifacts are suppressed but not eliminated. original FDK-based 36

Tangential Filtering Conventional filtering process is carried out along detector rows. Tangential filtering is carried out along the tangential direction of the source trajectory. z tangential filtering x O γ α conventional filtering β y S 37

Tangential Filtering conventional filtering tangential filtering 38

3D Helical Weighting The helical weighting function changes with projection angle β, detector angle γ, and cone angle α. z Experiments show that 3D weighting function provides significant improvement in image quality. β γ α 39

3D Helical Weighting off the shelf recon more expensive exact recon 3D weighting 40

Slice Thickness Change With Algorithm Slice thickness can be selected by modifying the reconstruction process. By low-pass filtering in the z-z direction, the slice sensitivity profile can be broadened to any desired shape and thickness. From an image artifact point of view, images generated with the thinner slice aperture is better. Filtering z 41

Example Z filtering can be applied in either the projection domain or the image domain. In general, z-smoothing z provides artifact suppression capability. 16x0.625mm detector aperture at 1.75:1 helical pitch FWHM=0.625mm FWHM=2.5mm 42

Cardiac Scans The most challenging problem in cardiac scanning is motion. Unlike respiratory motion, cardiac motion cannot be voluntarily controlled. For motion suppression, we could either reduce the acquisition time and/or acquire the data during the minimum cardiac motion. In cardiac motion, there are relative quiescent period: diastolic phase of the heart motion. 43

Halfscan In fan beam, each ray path is sampled by two conjugate samples. We need only 180 + fan angle data for complete reconstruction. 360 o 180 o +fan angle 0 o detector channels 44

Single-cycle Cardiac Reconstruction Projection data used in the reconstruction is selected based on the EKG signal to minimize motion artifacts. acquisition interval for image No. 1 acquisition interval for image No. 2 acquisition interval for image No. 3 acquisition interval for image No. 4-50 -100-150 magnitude -200-250 -300-350 0 0.5 1 1.5 2 2.5 3 3.5 4 time (sec) 45

Cardiac Imaging curved reformation Bypass Graft Follow-Up Gated Cardiac 20cm in 11s @ 0.625mm 46

Summary CT Image reconstruction techniques have been continuously developed over the years to match the advancement in new acquisition hardware and new acquisition techniques. With image explosion from the new CT scanners, advanced visualization tools are needed to improve the productivity of radiologists. Faster and better tools are constantly developed. 47

References J. Hsieh, Computed Tomography: principles, design, artifacts, and recent advances,, SPIE Press, 2002. J. Hsieh, CT Image Reconstruction, in RSNA Categorical Course in Diagnostic Radiology Physics: CT and US Cross-sectional sectional Imaging 2000,, ed. L. W. Goldman and J. B. Fowlkes, RSNA, 2000; pp. 53-64. A. Kak and M. Slaney, Principles of Computed Tomographic Imaging, IEEE Press, 1988. 48