Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller



Similar documents
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

UPBLAST & HOODED PROPELLER ROOF VENTILATORS

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ROOF TOP MOUNTED Air Handler Specification

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Ventilation Solutions Kitchens. fantech

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Roof Curbs, Extensions and Equipment Supports

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

product application guide

Explosion-Proof Electric Unit Heaters

Commercial Gas Furnace Upflow

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Miami-Dade Qualified Drainable Blade Louvered Penthouse

SECTION AIR CONDITIONING UNIT

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

TIGER Drylac U.S.A., Inc Swenson Avenue St Charles, IL T F office.us@tiger-coatings.us

AMD-33 Air Measuring Station with VCD-33 Control Damper

James M. Pleasants Company

Autobody/Collision and Repair Technology/Technician CIP Task Grid

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

Cooktop Low-Profile Ventilation Hoods

SECTION HEAT PUMPS

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

300 Series PA Pump and Cooler Assemblies

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

ULTRA 865HD HIGH PERFORMANCE MULTI PURPOSE GREASE

NFPA31FuelOilPiping 1 Revised

Johnson Air-Rotation Systems

HVAC Design Requirements

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Frequently Asked Questions Generators

SP H/M/L AFLR /1464/ /1469/ /22/ AFLR /8 1468/1209/ /6050/ /31/28 115

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CE6500 Energy Recovery Ventilator

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

PAINT BOOTH LIGHTING

RPV - RP - RA air handling units

MAC-120HE-01 Air-Cooled Chiller

Owner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!

Low Voltage Transformers Sealed, General Purpose, Dry Type

Table of Contents. I. Roof Scuttles

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

City of San Diego, CWP Guidelines

Life Safety Dampers Selection and Application Manual. Ceiling Radiation Dampers Fire Dampers Combination Fire Smoke Dampers Smoke Dampers

Application Guide Selection of Type Enclosures

SECTION 6. Glass Storefront Doors:

Fan Selection Application

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

PRESSURE REDUCING CONTROL VALVE

Screen Enclosure Protect your Screen against: rain, temperature, vandalism damage and theft

Fan Applications. Major Considerations Defined. Fan Application. Major Application Considerations. A. Fan Types FA/126-06

Installation, Safety, Operation & Maintenance Instructions And Parts List

Spray Booth Guideline

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

A. Section includes air conditioning units, controls and control panels.

SECTION MORTUARY REFRIGERATORS

POWERS Controls No. 4 Pneumatic Damper Actuator

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

SPECIFICATION DIVISION 23 SECTION DESCRIPTION DIVISION 23 HEATING, VENTILATING AND AIR CONDITIONING (HVAC) SECTION BLOWER COIL UNITS

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application and Design. Ratings. Features and Control Options.

AABC Specifications for Testing and Balancing HVAC Systems

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

PANDA SPRAY BOOTH FILTER INFORMATION

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

Packaged Terminal Air Conditioner Wall Sleeve Installation

Tube Type Oil Skimmer Comparison

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Compressed Gas Cylinder Program

INFRARED RADIANT HEATERS. air heaters

Transformer oil cooler ALFA A02

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

SIOUX HYBRID WATER HEATER

FIRE DAMPER APPLICATION GUIDE

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Dock Hardware & Accessory Products Catalog

Modular Make-Up Air Unit

LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Scraper Passage Indicator. Electrical Indicator. Features

CLEAR-DIVISIONS CENTERFOLD

INSTRUCTION MANUAL AND PARTS LIST MODEL 14-10

A. Air-Conditioning and Refrigeration Institute: 1. ARI Commercial and Industrial Air Filter Equipment.

HYDRAULIC LIFT TABLE CART 2200-LB.

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

INC Flexi-Sorb. Versatile Flexible Easy To Install Durable Good Noise Reduction Economical. Typical Applications

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Pipe Cutting and Beveling Clamshells

CORROSION RESISTANT FRP FANS & BLOWERS

Transcription:

Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller Belt Drive Low and High Pressure October 009

Features Page Header Tube Axial Roof Upblast Fans Greenheck belt drive tube axial upblast roof exhausters, Models TAUB-L and TAUB-H, are designed to efficiently remove and disperse contaminated air. Model TAUB-L is designed for low pressure applications, Model TAUB-H for high pressure applications. The upblast configuration is ideal for exhausting contaminants away from a building to prevent roof damage and recirculation of exhaust air. With the selection of the appropriate high temperature option, the TAUB-L and TAUB-H can also exhaust heat and smoke for either emergency situations or for continuous operation. Greenheck s versatile tube axial design can be used in most commercial and industrial applications. Typical applications include: General exhaust Industrial space ventilation Fume hood exhaust Paint booth exhaust TAUB Features: Belt drive with motor and drives out of airstream Propeller diameters from 4 to 60 inch (610-14 mm) Volume Range: 4,000 to 60,000 cfm (6,796-101,941 m /hr) Static Pressure: Up to 1.0 inch wg (48 Pa) Temperatures: Up to 00ºF (60ºC) continuously Fabricated Steel Propellers: The TAUB uses die formed, heavy-duty, welded fabricated steel propellers that are designed to meet a large range capacity and pressure requirements. The fabricated steel propellers also allow for high temperature operation. All TAUB propellers are dynamically balanced to assure vibration-free operation. Leading Edge Support All Greenheck products are supported by the industry s best product literature, electronic media, and Computer Aided Product Selection program (CAPS). You ll also find extensive product and Installation and Operation and Maintenance Manuals (IOM) information on the Internet. And, of course, you can always rely on the personal service and expertise of our national and international representative organization. To locate your nearest Greenheck representative call 71-9-6171 or visit our website at www.greenheck.com Quick Delivery and Quick Build Programs Greenheck s Quick Delivery (QD) and Quick Build (QB) Programs ensure rapid response time with your needs dictating manufacturing time. Use CAPS or visit www.greenheck.com to determine what programs are available for these products.

Value Page Added Header Features AMCA Licensed & UL/cUL Listed All sizes and configurations of the TAUB-L and TAUB-H have AMCA licensed air and sound performance data. In addition, UL/cUL 70 and UL Power Ventilators for Smoke Control Systems listings are available for TAUB models. Motors may be either 0 or 60 Hz. Greenheck Fan Corporation certifies that the TAUB-L and TAUB-H fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 11 and AMCA Publication 11 and comply with the requirements of the AMCA Certified Ratings Program. Models TAUB-L and TAUB-H are listed for Electrical UL 70, File No. E40001. Models TAUB-L and TAUB-H are listed as Power Ventilators for Smoke Control Systems, File No. MH1711. This listing includes UL 70. Both listings are optional and must be specified. Quality Construction Construction includes heavy gauge material used in the housing with integral venturi, windband, and curb cap. Rolled edges on the windband and damper blades are used for additional strength. Curb cap includes prepunched mounting holes. Electrostatic Powder Paint Powder coatings offer a uniform, durable, and high quality finish. Standard powder coating is a onecoat process applied over a phosphatized surface that meets or exceeds the corrosion resistance of a comparable wet paint. Greenheck offers a number of in-house coatings applied via electrostatic powder. The standard coating, Permatector, is excellent for indoor and mild outdoor applications. Consult Greenheck s Product Application Guide, Performance Coatings for Ventilation Products, for a complete listing of coatings and relative resistance. For corrosive environments (i.e. outdoor coastal), see page for information on our zinc-rich basecoat technology. Complete Assembly and Testing The TAUB is completely assembled and tested before shipment. Our inspectors check that the fan operates with minimal vibration and is electrically safe for field operation. Maintenance / Serviceable The TAUB incorporates the following value added features that allow for quick and easy field service. Bearing lubrication is performed through extended grease fittings located on the outside of the fan housing. An adjustable motor base is provided for tightening the fan belts. Model Number Code The model number code is designed to completely describe the fan. The correct code letters and numbers must be specified to identify fan size, propeller type and fan horsepower. TAUB 4L 0 Tube Axial Upblast Belt Drive Fan Size Sizes 4, 0, 6, 4, 48, 4, 60 L - Low Pressure H - High Pressure Motor Horsepower 4 = 1/4 10 = 1 0 = = 1/ 1 = 1½ 7 = 7½ = 1/ 0 = 100 = 10 7 = /4 0 = 10 = 1

Optional Page Header High Temperature Construction CONTINUOUS HI-TEMP OPERATION HT Option I - 00-00 F (9-60 C) The Model TAUB can be built to operate at up to 00 F (60 C) continuously for applications where exhaust temperatures exceed 00 F (9 C). Unlike the emergency smoke removal exhaust fans, this fan does not have fusible link damper lifters. Continuous high temperatures would trip the fusible links, holding the butterfly dampers open continuously. Tests were conducted at Greenheck s research and design facilities using a. million BTU gas-fired burner capable of generating airstream temperatures in excess of 1000 F (8 C). Temperatures were monitored at the following critical locations throughout the tests: bearings, bearing compartment, belt tube, motor, motor compartment, airstream, and fan housing. The following high temperature options and their construction are a result of this extensive testing. EMERGENCY SMOKE REMOVAL* To remove smoke in the event of a fire, three levels of emergency smoke removal exhausters are available. As indicated in the chart below, the following options all contain fusible link damper lifters. These fusible links melt at 16 F (74 C) and allow the spring-loaded damper lifters to open the dampers. This allows the fan to serve as a gravity exhaust vent in the event that the power supply to the fan is cut off. Although the TAUB fan may be built with one of the following emergency smoke removal exhaust options, it will still perform the everyday general ventilation requirements. HT Option II - 00 F (60 C) for a minimum of 4 hours This construction meets specifications requiring the fan to exhaust 00 F (60 C) air for a minimum of 4 hours in an emergency smoke removal situation per IRI requirements. HT Option Ill - 1000 F (8 C) for a minimum of 1 minutes This construction meets specifications requiring the fan to exhaust 1000 F (8 C) air for a minimum of 1 minutes in an emergency smoke removal situation per SBCCI Standard Fire Prevention Code. This construction also meets (and exceeds) IRI requirements for 00 F (60 C) for a minimum of 4 hours. HT Option IV - UL Listed Power Ventilators for Smoke Control Systems This construction meets specifications for UL Listed Power Ventilators for Smoke Control Systems. This includes the IRI requirements of 00 F (60 C) for a minimum of 4 hours, the SBCCI Standard Fire Prevention Code requirements of 1000 F (8 C) for a minimum of 1 minutes, and the Snow Load Test for butterfly dampers in UL-79. *Note: Even though some parts of the fan may be destroyed when subjected to extremely high temperatures caused by a fire, the emergency smoke removal exhaust fan has been designed to operate effectively for the temperature and minimum time limits stated, as long as power to the fan is not terminated. Special Construction Features for High Temperature Operation High Temperature Construction Features HT Option I High Temperature Options HT Option II HT Option III HT Option IV 16 F (74 C) Fusible Link Damper Lifters 16 F (74 C) Fusible Link Damper Lifters that will lift 10 lbs. per ft Vented Belt and Bearing Tube Steel Damper Blades* Dual Drives Copper Lubrication Lines High Temperature Paint UL Label (Power Ventilators for Smoke Control Systems) * All fans with high temperature options have steel damper blades. Special attention must be given to the fan selection to ensure the dampers will open based on performance. See each performance page for the minimum CFM required to open the dampers. 4

Coatings Page Header In 197, Greenheck took the lead as the first commercial and industrial fan manufacturer to introduce electrostatic powder coatings. Today, Greenheck continues to lead by being the first to offer a superior zinc-rich powder basecoat and powder coating finish. This zinc-rich basecoat technology is used extensively outside the HVAC industry to protect bridge beams, automotive components and other heavy-gauge steel products. Now this advanced technology is exclusively available on Greenheck welded steel products. Greenheck s coating process starts with a minimum of five wash stages to treat all components prior to painting. Cleaner parts result in better coating adhesion and durability. We then use an advanced two coat powder application method that includes a basecoat of zinc-rich powder and a topcoat of Greenheck s Permatector or Hi-Pro Polyester. The combination of these two topcoats over our new zincrich basecoat results in the two new coatings Perma-Z and Hi-Pro-Z. These oven cured coatings provide superior corrosion resistance along with a tough, uniform finish to combat the most extreme conditions. Zinc Advantage When compared to a traditional single coat application, the benefits of the two coat system include: An automatic powder coat application produces uniform coverage and unmatched paint quality. One Coat Process Topcoat - mils Base Steel Standard Surface Preparation The double coat thickness provides superior durability and protection from air and water. The zinc-rich basecoat includes an epoxy component that provides additional corrosion protection. The zinc-rich basecoat provides chemical protection of exposed steel to prevent corrosion. Two Coat Process Topcoat 4-6 mils Total Base Steel Zinc-rich Primer (70% zinc) Advanced Surface Preparation The protection offered by the zinc-rich base coats in Perma-Z and Hi-Pro-Z result in extraordinary corrosion resistance. Test data demonstrates our two-coat paint system offers three (Perma-Z) and four (Hi-Pro-Z) times the corrosion resistance of other coatings commonly available within the fan industry. See table for salt spray life for various coatings. Coating fans with Perma-Z or Hi-Pro-Z has reduced our customers annual paint maintenance costs by three to four times! Salt Spray ASTM B117 Hours 1000 000 000 4000 Permatector Hi-Pro Poly Perma-Z Hi-Pro-Z Baked Phenolic Epoxy Phenolic Fluorocarbon

Standard Page Header Construction & Accessories Standard Construction Housing Housing is continuously welded to prevent air leakage. The fan tube, curb cap, windband and motor cover are constructed of heavy gauge steel with Permatector coating. Butterfly Dampers Butterfly style dampers feature rolled edges for strength and weather protection. Damper stops maintain proper blade position when fan is operating. Gaskets line the edge of fan discharge for quiet damper closure. For sizes 4-0 aluminum material is standard and steel is standard for sizes 6-60. Aluminum blades optional on larger sizes. Bearings Bearings are air handling quality, grease lubricated, pillow block type. Bearings are selected with a basic rating fatigue life L 10 in excess of 40,000 hours at each fan s maximum operating speed. Extended Lube Lines Extended lube lines with grease fittings allow bearing lubrication from the fan exterior. Belt & Bearing Tube Belts, bearings, and drives are protected from the airstream by a heavy gauge steel belt tube and bearing cover. Adjustable Motor Bases Rigid structural steel motor bases are welded to the fan housing and include heavy-duty adjustment screws for belt tensioning. Drives Greenheck offers either constant or adjustable speed drives for fan speed adjustments. Belts are static free and oil resistant. Motors NEMA base-mounted motors are standard. Motors are available in open drip proof or totally enclosed. Motor Cover Weatherproof motor cover shields the motor and drive components from dust, dirt, and moisture. Motor covers meet OSHA standards. Accessories Outlet Screen Outlet screens constructed of steel mesh are available to shield dampers and fan discharge from debris. Fusible Link Damper Lifter Fusible link damper lifters automatically open butterfly dampers when the air temperature below the damper blades exceeds 16ºF (74ºC). The damper blades are held open to provide smoke and heat relief with no electric power required. Magnetic Latches Magnetic damper latches minimize damper flutter (due to pressure changes within the building) when the fan is not in operation. Inspection Door Bolted or hinged inspection door provides access through the fan tube for cleaning or inspection of the propeller, bearings, and drives. Inlet Guard Inlet guards provide protection for personnel and equipment in ducted or non-ducted installations. Inlet guards meet OSHA standards. Shaft Seal Shaft seals with aluminum rub rings are available to prohibit leakage of air into the bearing compartment of the fan. Tie Down Points A set of four tie down points are used to secure the fan to the roof deck when wind-loading is a concern. Special Coatings Special coatings are available for protective purposes. Coatings are applied before assembly so that each manufactured component is coated inside and out. Painting the exterior a specified color for appearance is also an option. Consult Greenheck s Product Application Guide, Performance Coatings for Ventilation Products for a complete listing of coatings and relative resistance. Roof Curbs A complete line of prefabricated roof curbs are available for mounting model TAUB fans. See the Greenheck Roof Curbs, Extensions & Equipment Supports catalog. Disconnect Switches Toggle and heavy-duty disconnect switches are available for positive electrical shut-off and safety in servicing fans. The following switches are available to meet individual electrical requirements and can be factory mounted or shipped loose for field mounting. NEMA-R Rainproof (outdoor) NEMA-4 Watertight (outdoor) NEMA-7 & 9 Class 1 and hazardous locations. Greenheck will not factory mount NEMA-7 & 9 disconnect switches. 6

Page Header Outlet Screen Butterfly Dampers Fusible Link Damper Lifter Motor Cover Tie Down Points (4 per unit) Adjustable Motor Base Inspection Door Inlet Guard 7

TAUB-4 Page Header Performance Data imum RPM Low Pressure 108 High Pressure 19 Specification Data imum Motor 184T Frame Size All dimensions in inches (millimeters). TAUB-4L (Low Pressure) TAUB-4H (High Pressure) Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only. 8 Shaft Diameter Recommended Roof Opening Approximate Fan Weight Imperial data Metric data 1/ /4 1 /4 1 1 1 1 [in.].4 [mm] 6 1 x 6 1 [in.] 67 x 67 [mm] 00 [lbs.] 16 [kg.] Material Gauges Fan Tube 1 Windband 0 Curb Cap 1 Minimum CFM required to open butterfly dampers Aluminum Steel 947 0 6.00 (660) 110 707 0.61 74 670 110 4 8 1170 71 0.70 4 7 9 8 4841 410 10 766 0.79 4 7 6176 6 14 488 1.1 (791) 4.00 (864) 6.8 (670).7 (140).0 (64) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 80 1 0.47 16.4 6 9 49 486 478 4068 84 09 0.0 17.0 64 4 04 4697 4494 46 860 40 0. 17.6 64 418 1 4804 4610 484 89 6 0.9 19.1 66 69 6 0 4877 468 91 749 0.6 0 67 76 497 194 09 4841 4189 9 874 0.67 1 67 891 69 4 180 499 4446 960 601 0.7 69 6048 79 09 61 187 4714 98 6188 0.79 4 70 606 97 68 8 78 4978 1000 68 0.8 70 601 606 787 64 491 14 100 6408 0.87 6 71 647 6186 9 786 64 04 469 1040 64 0.9 6 71 6 617 606 96 789 461 491 1060 6660 0.98 7 7 6679 6447 600 6066 9 616 18 108 6817 1.0 7 7 686 6610 67 641 6109 809 94 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 180 804 0.91 76 6480 978 499 498 409 140 8419 1.04 7 77 6784 699 81 9 4777 14 9016 1.8 0 79 76 680 6401 941 481 4849 1 9644 1.7 4 81 7771 74 699 641 6111 6 18 998 1.7 7 8 804 7601 7 687 641 998 414 1640 1004 1.91 9 8 80 789 74 719 677 6 841 1690 10618.09 9 8 86 819 7806 740 7060 6669 6 1770 1111.41 4 84 8961 88 88 7911 78 7166 679 180 116.7 4 86 966 900 8668 87 8011 764 798 6407 19 117.14 48 87 9796 9449 91 88 808 8166 78 7061

TAUB-0 Page Header Performance Data imum RPM Low Pressure 1090 High Pressure 16 Specification Data imum Motor 1T Frame Size Shaft Diameter Recommended Roof Opening Approximate Fan Weight Imperial data Metric data All dimensions in inches (millimeters). TAUB-0L (Low Pressure) /4 1 1 1 TAUB-0H (High Pressure) /4 1 1 1 1 1 4 [in.] 1.7 [mm] 1 x 1 [in.] 86 x 86 [mm] 9 [lbs.] 180 [kg.] Material Gauges Fan Tube 1 Windband 0 Curb Cap 1 Minimum CFM required to open butterfly dampers Aluminum Steel 604 719 1. (794) 800 68 0.61 0 7 7918 696 79 870 68 0.78 74 8611 774 677 14 7.8 (949) 40.00 (1016) 7.0 (699) 6.7 (1441) Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only..0 (64) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 64 06 0.6 1.8 64 800 7690 711 678 690 419 0.79 17.7 66 877 801 7784 7481 7170 70 64 0.90 18.7 67 914 870 810 798 7640 7 99 1.04 0 68 999 9171 8704 846 8181 7461 79 64 1.1 69 10107 9701 96 908 8791 8 80 618 1.8 70 10 1016 9747 9 917 8801 86 679 1.6 71 10997 1064 100 100 9817 94 8779 90 7107 1.78 7 7 1106 11149 10777 1080 108 994 9480 90 704 1.94 8 7 1184 11476 11118 1096 1074 10 9871 9 700.10 0 7 114 1180 1148 1171 11084 10708 109 1000 78.41 7 1714 191 1066 11888 11710 11 10949 104 807.7 6 76 186 1977 1667 101 11 11989 1161 1041 1090 860.1 9 78 188 16 16 111 1948 161 194 111 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 910 7147 0.90 7 9007 8181 74 6047 9 700 1.0 7 77 94 8670 7800 677 10 800 1.9 0 79 1014 944 86 771 697 109 8600 1.8 80 1088 10171 94 864 76 110 90 1.8 4 81 118 1074 100 911 846 74 10 9464.10 8 1197 11 10668 9986 90 86 190 1011.8 8 8 1768 10 1160 1097 1080 96 898 180 1088.1 4 84 169 1147 180 1199 119 10708 990 146 1106.76 47 86 1400 14018 1494 1946 189 11777 111 940 10 117 4.47 4 88 141 1488 14400 1884 19 184 11 1084 16 1841.4 6 89 1618 170 199 14811 1417 1818 17 1097 9

TAUB-6 Page Header Performance Data imum RPM Low Pressure 790 High Pressure 17 Specification Data imum Motor 1T Frame Size Shaft Diameter Recommended Roof Opening Approximate Fan Weight Imperial data Metric data 1 1 [in.] 8.1 [mm] 8 1 x 8 1 [in.] 978 x 978 [mm] 0 [lbs.] 41 [kg.] All dimensions in inches (millimeters). TAUB-6L (Low Pressure) 1 1 1 Material Gauges Fan Tube 1 Windband 0 Curb Cap 1 Minimum CFM required to open butterfly dampers Aluminum Steel 7618 10981.7 (87) 4.0 (110) 46.00 (1168).6 (89) 64.8 (16).0 (64) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 4948 0.9 1. 64 11 11414 1061 10169 4 16 1.04 1.8 6 1697 11909 1118 1076 10 70 7 1.19 16.7 6 180 1 11786 1140 10987 90 60 1. 17.4 66 1746 101 100 11947 118 60 701 1.4 17.9 67 1409 18 1684 19 1199 110 6 890 1.6 18.8 67 1461 187 1194 189 16 1168 6 617 1.80 19.9 68 160 1460 194 16 11 191 67 661 1.97 1 68 176 1088 1448 1414 186 1189 10 690 60.11 1 69 16076 141 1484 148 14 16 179 70 678.9 69 1677 16176 184 190 14998 14419 1707 74 701.6 4 70 177 16779 160 191 168 1078 1447 76 709.87 71 178 1760 16700 1644 16148 1601 10 790 744.16 7 71 18406 17860 1717 17049 1678 161 174 TAUB-6H (High Pressure) 1 1 1 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 67 661 0.77 1 7 1099 97 7998 74 701 1.04 4 74 11 11019 9601 71 800 79 1.9 7 76 108 1199 10779 9140 8 808 1.7 0 78 194 196 11867 10478 810 90 89 1.86 80 1478 18 18 1197 10081 940 889.09 4 81 108 14440 1488 14 109 98 98.40 7 8 16041 116 14 111 104 1047 100 9707.7 40 8 16774 1988 1161 140 106 1171 107 1011.1 44 8 1707 1676 196 1070 14041 184 1107 11 1060.8 48 86 181 1760 1681 160 1109 1400 1769 117 11074 4.08 87 1916 18448 177 16966 1610 1116 1996 1 114 4.6 88 1990 1991 18608 17900 17088 16194 1194 140 17 1016.0 9 89 0764 011 19479 18810 18046 176 169 14107 Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only. 10

TAUB-4 Page Header Performance Data imum RPM Low Pressure 7 High Pressure 100 Specification Data imum Motor 1T Frame Size Shaft Diameter Recommended Roof Opening Approximate Fan Weight Imperial data Metric data 1 1 [in.] 8.1 [mm] 44 1 x 44 1 [in.] 110 x 110 [mm] 71 [lbs.] [kg.] All dimensions in inches (millimeters). TAUB-4L (Low Pressure) Material Gauges Fan Tube 10 Windband 0 Curb Cap 10 Minimum CFM required to open butterfly dampers Aluminum Steel 1104 11 7. (946) 49.88 (167).00 (11) 4. (870) 71.00 (180) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 460 07 1.9 14.6 6 1719 16169 1017 147 16 1 1 49 44 1.9 16.4 6 184 17 164 197 19 10 607 1.76 17. 6 18991 1817 1716 1698 198 147 77 1.9 18.0 66 190 1870 17784 1764 16669 1474 40 97.08 18.9 67 0108 1901 18401 179 1746 16186 6 61.40 0 68 109 068 194 1897 18464 176 164 90 6487.7 69 1970 1 046 0008 1969 1809 1744 60 6817.14 4 71 087 84 164 18 081 19871 18860 640 707.44 71 8 11 446 0 168 0768 19790 66 71.86 7 7 476 4108 444 06 68 1879 098 690 786 4.7 8 7 694 06 441 407 706 97 07 19800 71 7861 4.84 0 74 66 601 406 074 471 4016 19 1004 7 8081.4 74 770 6777 6184 87 0 484 408 19.0 (64) TAUB-4H (High Pressure) 1 1 1 7 1 0 0.9 17.7 69 147 14 96 77 1.04 18.7 70 1488 1914 104 6 61 1.8 1 7 1968 1416 106 60 66 1.8 74 17099 1478 1 1101 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 6 698 1.8 7 17946 16414 1460 1409 66 71.11 7 77 18794 174 164 170 1101 69 7641.9 9 78 1964 186 16669 14886 14 760 86.14 80 1479 044 18846 1760 110 1161 80 916 4.10 8 8 48 9 108 19694 1804 16474 1488 900 9896. 44 84 46 496 7 08 074 190 1767 940 10.9 47 8 667 70 41 86 109 079 1997 10 98 1080 6.8 1 86 788 6888 89 487 646 41 111 17848 100 11 7.8 88 9110 801 770 648 161 996 788 1994 Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only. 11

TAUB-48 Page Header Performance Data imum RPM Low Pressure 64 High Pressure 90 Specification Data imum Motor 4T Frame Size Shaft Diameter Recommended Roof Opening Approximate Fan Weight Imperial data Metric data All dimensions in inches (millimeters). TAUB-48L (Low Pressure) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 4461 1.9 1. 64 088 1910 1748 164 1 1 80 477 1.9 16.4 6 08 066 19168 1876 176 7 1 1 4 [in.] 44.4 [mm] 0 1 x 0 1 [in.] 18 x 18 [mm] 90 [lbs.] 418 [kg.] Material Gauges Fan Tube 10 Windband 0 Curb Cap 10 Minimum CFM required to open butterfly dampers Aluminum Steel 191 1641 4.7 (1086) 6.00 (14) 8.00 (147) 400 06 1.8 17.9 66 198 1894 0484 1970 18840 41 1.07 19. 67 4067 811 146 076 1999 40 64.6 69 6097 499 717 084 40 088 47 969.10 6 71 747 6449 09 4709 4110 708 40.00 (1016) 00 68.61 7 7 8997 794 6887 618 748 401 117 0 6660 4.0 9 7 077 97 8766 89 7691 6616 11 6 7099.1 76 767 1844 091 047 99 894 7818 76.7 (1949) 8 71.78 4 77 97 0 144 1690 10 09 99 60 760 6.40 77 086 4 6 9 466 14 08 7767 6 78 7.06 6 78 646 41 478 4161 7 81 1900 94 64 810 7.76 7 78 7406 698 789 8 4974 4091 08 070.0 (64) TAUB-48H (High Pressure) 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 40 64 1.9 7 1961 1710 1778 1 1 48 6094 1.9 7 108 18907 1600 7 1 10 0 646 1.84 6 74 19 1990 1718 187 697.06 7 7 81 08 186 116 6 7099. 0 77 460 740 0408 1777 60 760.1 78 699 460 40 01 1741 660 89 4.11 9 81 8690 7146 409 66 1009 1894 71 8984.4 4 8 1081 9664 8189 67 469 01 19611 76 961 6.4 49 8 4 198 09 8869 70 197 9 80 1004 7.70 4 87 64 446 140 171 998 877 6474 84 10618 8.61 7 88 67 1 40 001 116 961 7998 946 87 1099 9.0 61 89 806 6896 697 449 898 181 9684 97 90 117 10.4 6 90 940 88 708 918 446 89 148 788 Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only. 1

TAUB-4 Page Header Performance Data imum RPM Low Pressure 9 High Pressure 84 Specification Data imum Motor 6T Frame Size Shaft Diameter [in.] 0.8 [mm] Material Gauges Fan Tube 10 Windband 18 Curb Cap 10 Minimum CFM required to open butterfly dampers 6.6 (191) Recommended 6 1 x 6 1 [in.] Roof Opening 14 x 14 [mm] Approximate 10 [lbs.] Aluminum Steel Fan Weight 68 [kg.] 1600 14 Imperial data Metric data 47. All dimensions in inches (millimeters). (100) 64.00 (166) TAUB-4L (Low Pressure) 7 1 10 44.00 (1118) 86.7 (0) Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only..0 (64) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 47 1.8 19. 68 788 900 60 74 0 4948.11 0 69 910 77 07 9 0 80 7.71 71 1600 9947 7960 697 8 400 64.16 7 64 1707 984 8874 7894 14 40 97.6 9 74 497 444 170 0797 986 7760 44 691 4. 7 7006 607 4007 161 89 007 470 6644.1 4 77 908 7760 687 486 4681 01 1084 490 697.80 44 78 40748 9477 8098 70 66 497 88 1 780 6.74 4 80 487 41618 4048 9617 8887 79 87 40 764 7.77 47 81 44906 47 48 41887 41190 9789 86 7846 8.4 48 8 461 401 4910 441 46 4108 9799 760 7 818 9.8 0 8 47817 4674 461 409 448 4077 417 8000 9 8411 10.9 8 49480 484 4787 4680 46198 449 46 4008 TAUB-4H (High Pressure) 7 1 10 1 400 64 1.67 71 7 88 1800 44 691.9 74 84 66 07 16986 490 697.07 9 76 107 8776 788 06 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 1 780.6 1 78 90 0490 7807 48 1978 0 777 4.4 80 141 87 0479 7409 91 8 870. 40 81 777 6 106 041 79 47 6 88 6.8 4 8 99 790 980 606 0774 776 80 670 9471 7.84 1 8 4808 4091 9111 706 480 1878 898 700 9896 8.96 86 447 4919 41179 916 704 414 187 7 1090 10.4 61 88 46961 441 476 419 989 7490 014 896 770 1088 11.90 6 89 49197 476 499 4484 41 4086 808 08 80 1180 1.64 69 90 144 4986 488 468 411 44 4106 601 84 1194 1.71 7 91 989 49 101 4986 481 461 4464 40101 1

TAUB-60 Page Header Performance Data imum RPM Low Pressure 1 High Pressure 7 Specification Data imum Motor 84T Frame Size Shaft Diameter Recommended Roof Opening Approximate Fan Weight Imperial data Metric data All dimensions in inches (millimeters). TAUB-60L (Low Pressure) 7 1 10 TAUB-60H (High Pressure) 7 1/ 10 1 [in.] 0.8 [mm] 6 1 x 6 1 [in.] 188 x 188 [mm] 147 [lbs.] 670 [kg.] Material Gauges Fan Tube 10 Windband 18 Curb Cap 10 Minimum CFM required to open butterfly dampers Aluminum Steel 1801 480 1 4948.9 19.7 69 1 9408 10.6 1 70 1 08 4 419.1 71 19 74 9689 0.7 (189) 80 969.14 7 1149 7 1706 40 674.1 79 47 187 7989 49 68.7 (1746) 70.00 (1778) 48.1 (1) 9.7 (81).0 (64) 0.000 0.00 0.100 0.1 0.10 0.00 0.0 0.7 6 7.7 7 7 4961 18 80 969 4.0 6 74 876 6607 91 48 9 604 4.7 8 7 409 844 746 4 410 6440.8 9 76 418 9867 74 616 461 40 674 6.09 1 77 486 41998 9844 876 781 40 7068 6.98 4 78 490 4411 4097 40960 97 46 704 7.70 7 79 474 4709 477 471 41 89 480 79 8.47 40 80 4896 479 444 4446 40 41008 00 78 9.8 44 81 1004 49400 47660 46716 4704 447 1 8089 10.46 47 8 4 0976 491 4896 47470 406 0.000 0.1 0.0 0.7 0.00 0.6 0.70 1.000 470 78 4.0 44 8 86 60 198 709 1807 10 8011.1 4 8 4180 880 877 81 7617 840.98 4 8 484 4094 874 14 040 897 60 8796 6.91 8 4904 4070 4064 76 1 9709 8 9189 7.84 86 479 4188 4986 40089 6874 801 61 9660 9.16 6 86 041 4770 468 4011 4079 90 7 64 1011 10.0 7 87 871 046 4899 4898 48 40019 617 690 1088 1.8 61 88 660 4106 19 0166 47706 477 41607 4844 7 114 1.7 68 90 6049 794 607 41 06 49766 4748 4061 Performance ratings do not include the effects of appurtenances (accessories). Power ratings () does not include transmission losses. The sound ratings shown are loudness values in fan sones at ft. (1. m) in a hemispherical free field calculated per AMCA Standard 01. Values shown are for Installation Type A: free inlet hemispherical sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only. 14

Tube Page Axial Header Family Greenheck offers a full-line of tube axial fans for a variety of applications. Spark Resistance - Inline Cast Aluminum Propeller TBI-CA and TDI axial fans are a practical choice for inline applications involving clean air or air containing volatile compounds. Can be used in either ducted or non-ducted applications. Cast aluminum hub and airfoil blades provide spark resistant construction. These models have capabilities best suited for 1 to inches wg (49-747 Pa) of static pressure. Three levels of construction provide efficient and economical selections for reliable performance in commercial and industrial applications. Typical applications include: General exhaust, supply or return air Paint booth exhaust Industrial or commercial space ventilation Emergency smoke exhaust Fume hood exhaust Levels four and five available in roof upblast style. Lower Pressures Higher Pressures TAUB-CA TAUD TDI TBI-CA Level TBI-CA TDI Level 4 TBI-CA Level TDI High Temperatures - Inline Steel Propeller Model TBI-FS inline fans are the ideal choice for installations for high temperature applications, continuous duty or emergency use. Designed for commercial and industrial applications where air volumes up to 77,000 cfm (10,000 m /hr) and moderate pressures to 4 inches wg (996 Pa). TBI-FS models have continuously welded housing and are belt-driven with motors and drives out of the airstream. All propellers are constructed with airfoil blades that are continuously welded to heavy-duty hubs to ensure long life in the harshest applications. Typical applications include: General exhaust, supply or return air Industrial space and warehouse ventilation UL/cUL listed for emergency heat and smoke removal High temperature process ventilation Lower Pressures High Temp Option Operating Temperature Time Duration F C Hours Std. Construction 180 8 Continuous HT-I (Inline) 400 04 Continuous HT-I (Roof Upblast) 00 60 Continuous HT-II 00 60 4 7 00 1 HT-III 7 400 1000 8 1 00 149 HT-UL/cUL 70 99 4 1000 8 0. Higher Pressures TAUB-L/H TBI-FS Level TBI-FS Level 4 TBI-FS Level 1

Specifications Roof mounted upblast exhaust fans shall be of the belt-driven tube axial type. Propeller construction shall be fabricated steel. A standard square key or tapered bushing shall lock the propeller to the shaft. Propellers shall be statically and dynamically balanced. Fan tube and curb cap shall be constructed of heavy-gauge steel and an integral venturi inlet. Curb cap shall have prepunched mounting holes. These components shall be coated with an industrial grade paint. Windbands shall be constructed of heavygauge painted steel with reinforced edges. Bearing supports shall be constructed of structural steel members to prevent vibration and rigidly support the shaft and bearings. All structural steel parts shall be coated with an industrial grade paint to provide a lasting finish. Fan shaft bearings and drives shall be isolated from the airstream. Turned, precision ground and polished steel shafts shall be sized so the first critical speed is at least % over the maximum operating speed. Close tolerances shall be maintained where the shaft makes contact with the bearing. Bearings shall be air handling quality, heavyduty, grease lubricated, self-aligning ball type in pillow block mounts. Bearings shall be selected for a minimum L 10 life in excess of 40,000 hours at maximum operating speed. Extended lubrication lines shall be provided with external grease fittings. *For high temperature applications, insert the appropriate verbiage here. High temperature specifications are provided. All fans shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Each fan shall bear a permanently affixed manufacturer s nameplate containing the model number and individual serial number for future identification. Fans shall be Model TAUB as manufactured by Greenheck Fan Corporation of Schofield, Wisconsin. *Specifications for high temperature operation. (Insert the applicable high temperature verbiage into the main specification.) HT Option I - 00-00 F (9-60 C): Fan shall be capable of operating continuously at a temperature between 00 F and 00 F (9-60 C). HT Option II - 00 F (60 C) for a minimum of 4 hours: Fan shall meet the requirements of IRl for operation at 00 F (60 C) for a minimum of 4 hours in an emergency situation. HT Option Ill - 1000 F (8 C) for a minimum of 1 hours: Fan shall meet the requirements for the SBCCI Standard Fire Prevention Code for operation at 1000 F (8 C) for a minimum of 1 minutes in an emergency situation. HT Option IV - UL Listed Power Ventilators for Smoke Control Systems: Fan shall meet the requirements for UL Listed Power Ventilators for Smoke Control Systems. This will include meeting the IRI requirements of 00 F (60 C) for a minimum of 4 hours, the SBCCI Standard Fire Prevention Code requirements of 1000 F (8 C) for a minimum of 1 minutes, and the Snow Load Test for butterfly dampers in UL 79. Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI 4476-0410 Phone (71) 9-6171 greenheck.com TAUB Rev. October 009 HG Copyright 009 Greenheck Fan Corp.