Installation, Safety, Operation & Maintenance Instructions And Parts List
|
|
|
- Percival McCormick
- 10 years ago
- Views:
Transcription
1 Installation, Safety, Operation & Maintenance Instructions And Parts List For Model BAF, Belt Drive Tube Axial Fan Arrangement 9 NOTE READ ENTIRE MANUAL INCLUDING SECTION IV. INITIAL UNIT STARTUP BEFORE ATTEMPTING TO INSTALL AND OPERATE THIS EQUIPMENT. FAN SPECIFICATIONS Form: OMM Effective: 2/21/11 Supersedes: OMM Part No.: FAN SERIAL NUMBER: MFG. DATE: NOTE: The serial number above is a required reference for any assistance. It is stamped on the fan nameplate. FAN SPECIFICATIONS: Model: Propeller Number: FAN PERFORMANCE DATA: (If entered on order) CFM: SP: (Inches of Water Gauge) Motor BHP: Density: Altitude: (Ft. above S.L.) Airstream Temperature: F. Fan RPM: Maximum Safe Fan RPM: DO NOT EXCEED THIS RPM MOTOR DATA: (This section is completed only if the motor was supplied by Cincinnati Fan) HP: RPM: Voltage: Phase: Hz: Frame Size: Enclosure: Efficiency: IF Motor is EXP, Class(es) & Group(s) are: Manufacturers Model Number: CFV Part Number: DRIVE DATA: Fan Sheave: Motor Sheave: Belts: No. of Grooves: Fixed Speed: Adjustable Speed: ATTENTION: RECEIVING DEPARTMENT All Cincinnati Fan products are packaged to minimize any damage during shipment. The freight carrier is responsible for delivering all items in their original condition as received from Cincinnati Fan. The individual receiving this equipment is responsible for inspecting this unit for any obvious or concealed damage. If any damage is found, it should be noted on the bill of lading before the freight is accepted and the receiver must file a claim with the freight carrier. LONG TERM STORAGE NOTICE If this fan will NOT be installed and put into operation within 30 days, refer to the Long Term Storage Instructions on page 14. Failure to follow all applicable long term storage instructions, will void your warranty. This fan should be stored indoors in a clean, dry location. OMM page 1
2 DANGER Hazardous voltage High speed rotating Lock out/tag out to Avoid injury. NEVER Avoid injury. You MUST can cause electrical equipment can cause prevent personal injury operate without ALL read and understand all shock and death. severe personal injury. BEFORE starting ANY required safety instructions in this manual service or inspection. guards in place. BEFORE installing. TABLE OF CONTENTS I. GENERAL A. Unpacking and Handling...2 B. Safety Instructions & Accessories II. INSTALLATION A. Vibration...3 B. Mounting Methods C. Safety Guards...4 D. Dampers and Shutters...4 E. Set Screw and Taper-lock Bushing Torque Values...4 F. Fan Bearings...4 G. V-Belt Drives...5 H. V-Belt Drive Installation...5 III. ELECTRICAL A. Disconnect Switches...5 B. Motors C. Maximum Speed & Speed Controllers...7 IV. INITIAL UNIT STARTUP A. Pre-Startup & Post-Startup Checks B. Vibration...8 V. ROUTINE INSPECTION & MAINTENANCE A. Hardware...8 B. Motor and Fan Bearing Lubrication...8 C. Propeller Balance...8 D. Vibration...9 E. Replacing Belts ONLY F. Replacing Shaft & Bearing Assembly, belt and sheaves G. Dampers and Shutters...12 H. Safety Equipment & Accessories...12 VI. ORDERING REPLACEMENT PARTS...12 VII. TROUBLESHOOTING...13 VIII. LONG TERM STORAGE...14 IX. LIMITED WARRANTY...15 LIMITS OF LIABILITY...15 RESPONSIBILITY...15 RETURNS...15 X. PARTS DRAWING...16 I. GENERAL A. Unpacking: Be careful not to damage or deform any parts of the fan when removing it from the packaging container. All the packaging material should be kept in the event the fan needs to be returned. Handling: Handling of the fan should be performed by trained personnel and be consistent with all safe handling practices. Verify that all lifting equipment is in good operating condition and has the proper lifting capacity. The fan should be lifted using well-padded chains, cables or lifting straps with spreader bars. NEVER lift the fan by an inlet or discharge flange, fan or motor shaft, motor eye bolt, or any other part of the fan assembly that could cause distortion of the fan assembly. B. Safety Instructions & Accessories: 1. Safety Instructions: All installers, operators and maintenance personnel should read AMCA Publication , Recommended Safety Practices for Users and Installers of Industrial and Commercial Fans. This manual is included with the fan. Additional copies can be requested by writing us at Cincinnati Fan, 7697 Snider Rd., Mason, OH Sound: Some fans can generate sound that could be hazardous to personnel. It is the responsibility of the user to measure the sound levels of the fan and/or system, determine the degree of personnel exposure, and comply with all applicable safety laws and requirements to protect personnel from excessive noise. OMM page 2
3 3. Air Pressure and Suction: In addition to the normal dangers of rotating machinery, the fan can present additional hazards from the suction or pressure created at the fan inlet or discharge. Suction at the fan inlet can draw materials into the fan where they become high velocity projectiles at the discharge and cause severe personal injury or death. It can also be extremely dangerous to persons in close proximity to the inlet or discharge as the forces involved can overcome the strength of most individuals. WARNING NEVER OPERATE A FAN WITH A NON-DUCTED INLET AND/OR DISCHARGE. IF THE FAN INLET AND/OR DISCHARGE IS NON-DUCTED, IT IS THE USERS RESPONSIBILITY TO INSTALL AN INLET AND/OR DISCHARGE GUARD. 4. Temperature: Many fans, fan components and all motors operate at temperatures that could burn someone if they come in contact with them. If this potential hazard could exist in your installation, steps must be taken by the user to protect anyone from coming in contact with this equipment. The maximum airstream temperature for this fan is 175 F. (79 C.) 5. Spark Resistance: (Per AMCA Standard and ISO 13499) DANGER NO GUARANTEE OF ANY LEVEL OF SPARK RESISTANCE IS IMPLIED BY SPARK RESISTANT CONSTRUCTION. IT HAS BEEN DEMONSTRATED THAT ALUMINUM IMPELLERS RUBBING ON RUSTY STEEL CAN CAUSE HIGH INTENSITY SPARKS. AIR STREAM MATERIAL AND DEBRIS OR OTHER SYSTEM FACTORS CAN ALSO CAUSE SPARKS. 6. Safety Accessories: Guards: All moving parts must be guarded to protect personnel. Safety requirements can vary, so the number and types of guards required to meet company, local, state and OSHA regulations must be determined and specified by the actual user or operator of the equipment. NEVER start any fan without having all required safety guards properly installed. All fans should be checked on a regular schedule, for missing or damaged guards. If any required guards are found to be missing or defective, the power to the fan should be immediately turned off and locked out in accordance with OSHA regulations. Power to the fan should NOT be turned back on until the required guards have been repaired or replaced. This fan can become dangerous due to a potential windmill effect, even though all electrical power has been turned off or disconnected. The fan propeller should be carefully secured to prevent any rotational turning BEFORE working on any parts of the fan/motor assembly that could move. 7. Access or Inspection Doors: DANGER NEVER OPEN ANY ACCESS OR INSPECTION DOORS WHILE THE FAN IS OPERATING. SERIOUS INJURY OR DEATH COULD RESULT FROM THE EFFECTS OF AIR PRESSURE OR AIR SUCTION. DISCONNECT OR LOCK OUT POWER TO THE FAN AND LET THE FAN PROPELLER COME TO A COMPLETE STOP BEFORE OPENING ANY TYPE OF ACCESS OR INSPECTION DOOR. II. INSTALLATION A. Vibration: Before any mounting method is selected, the user should be aware of the effects vibration will have on the fan, motor and other parts. Improper fan installation can cause excessive vibration causing premature prop and/or bearing failure, that is not covered under warranty. Vibration eliminator pads or springs should be properly installed to prevent any fan vibration from transmitting to the foundation or support structure. I WARNING SHUT THE FAN DOWN IMMEDIATELY IF THERE IS ANY SUDDEN INCREASE IN VIBRATION. B. Mounting Methods: 1. In Duct Work Any component of a building structure that will be supporting the fan and any duct work must have the weight load capacity and be rigid enough to support the weight of the fan without bending, bowing or flexing during operation. If not, severe vibration can occur that could lead to fan and/or structural failure. Consult an architectural or structural engineer for assistance. OMM page 3
4 Model BAF fans are designed to be mounted in duct work of the same diameter as the fan. The flange rings are prepunched and should be bolted to duct flanges having the same dimensions. We do offer companion rings, as an option, to make the connection process easier. These fans can be mounted with the fan and motor shaft in a horizontal or vertical up-blast (motor shaft down) configuration. DANGER If this fan will be mounted in a vertical down-blast configuration, with the motor shaft up, the propeller MUST be secured to the fan shaft with a pin or locking collar. If there is no pin or locking collar to additionally secure the propeller to the fan shaft, DO NOT use the fan without adding this feature. Not providing this feature could lead to property damage, injury or death. The use of flexible connectors on the inlet and outlet of the fan will make it possible to mount this fan in a duct system and isolate any fan/motor vibration from the duct work. If flexible connectors will be used, the fan should be equipped with horizontal or vertical support clips. Threaded rod should be used to connect the support clips to the building structure. Each rod should be strong enough to support two (2) times the weight of the entire fan/motor assembly. Spring hangers would be needed on the rods to isolate any fan vibration from the building. 2. On Machinery If this fan will be mounted on machinery, the surface it will be mounted to must be strong and rigid enough to support the weight of the entire fan without flexing, bowing, bending or oil-canning and thus causing vibration. Companion rings are available that will match the flanges on the BAF fan. To minimize any leakage, it is recommended that some type of caulking be used between the fan flange and the machine. C. Safety Guards: Cincinnati Fan offers guards, as optional, to keep your fan in compliance with OSHA safety regulations. These include inlet or discharge guards and belt guards. It is the responsibility of the user to make sure this fan meets all local, state and OSHA safety regulations. If you have a specific guard requirement not covered by OSHA, please contact the local Cincinnati Fan sales office for assistance. D. Dampers and Shutters: (Airflow control devices) If the fan is supplied with any type of air flow control device, it should be closed before initial startup of the fan to minimize overloading of the motor. Any airflow control device, with bearings, should be maintained in accordance with the manufacturers instructions. Any air flow control device, with an automatic control mechanism, should be adjusted per the manufacturers recommendations. E. Set Screw and Taper-lock Bushing Torque Values: All propeller set screws are tightened to the proper torque prior to shipment. Some props may have taper-lock hubs and split, taper-lock bushings to secure the prop to the fan shaft. NOTE: Check all set screw or taper-lock bushing torques. Forces encountered during shipment, handling, rigging and temperature can affect factory settings. For correct torque values, see Tables 1 and 2 below. Diameter & Number of Treads/Inch 1/4-20 5/ /8-16 7/ /2-13 5/8-11 Table 1 SET SCREW TORQUE VALUES Hex Wrence Size (Across Flats) 1/8 5/32 3/16 7/32 1/4 5/16 Required Torque (Inch Pounds) Table 2 TORQUE VALUES FOR TAPER-LOCK BUSHINGS Required Torque (Inch Pounds) Taper-lock Bushing Size H B P Q R CAUTION Set screws should NEVER be used more than once. If the set screws are loosened, they MUST be replaced. Use only knurled, cup-point, set screws with a nylon locking patch. F. Fan Bearings: The bearings used in Model BAF fans are sealed-for-life bearings that require no additional lubrication for the life of the bearings. The bearings are pressed into the bearing housing and are held in place, on the fan shaft, with locking rings and Lock-Tite. If the bearings wear out, the entire shaft/bearings/bearing housing assembly should be replaced. The maximum airstream temperature for this fan is 175 F (79 C). OMM page 4
5 G. V-Belt Drives: If Cincinnati Fan supplied the belts and sheaves (drives package), they were carefully selected for the specific operating conditions supplied to us by the customer. DANGER Changing any of the v-belt drive component selections, supplied with the fan, could result in unsafe operating conditions which could cause equipment failure, personal injury and death. If the user is supplying the sheaves and/or belts, it is their responsibility to make the correct component selections for the specific operating conditions. Their selection must also NOT ALLOW the fan to exceed its maximum safe speed or hub load. If you do not know the maximum safe speed or hub load for this fan, DO NOT make any drive selection without first consulting Cincinnati Fan or our sales office for your area. Timing belts should never be used on fans. If you are replacing belts and/or sheaves, checking belt tension or proper alignment, see below and pages 9 through 12. Sheave set screws or taper-lock bushing bolts should be tightened to the torque values as indicated in Tables 1 and/or 2 on page 4. H. V-Belt Drive Installation: All Tube Axial fans shipped from Cincinnati Fan are supplied with belts and sheaves even if the motor is not supplied by Cincinnati Fan. If you are supplying the motor, you will also need to install the drives after the motor is installed onto the motor base. No power should be connected to the motor until AFTER the drives are properly installed. Fig. 1 If you are installing the drives, the most critical steps are alignment of the sheaves and proper belt tension. Misaligned sheaves and/or improper belt tension are the 2 leading causes of excessive fan vibration and premature belt and/or bearing failure of the fan and/or motor bearings. This is a non-warranty event. The fan and motor shafts must be parallel and the sheaves must be in-line with each other. See Fig. 1 at right: Shafts not parallel Sheaves not aligned Proper alignment For complete drive installation instructions, please see these websites: Browning Mfg. (Division of Emerson): For Catalog MCC10005, Form Maska (Division of Baldor): NOTE: If you are installing the drives along with your motor on a new fan, see Section E on pages 9 and 10 of this manual. III. ELECTRICAL A. Disconnect Switches: All fan motors should have an independent disconnect switch located in close visual proximity to turn off the electrical service to the fan motor. Disconnects must be locked out in accordance with OSHA lock out-tag out procedures any time inspection or maintenance is being performed on the fan and/or motor assembly. The lock out-tag out procedure should be performed by a licensed electrician or authorized personnel. All disconnects should be sized in accordance with the latest NEC codes (National Electric Codes) and any local codes and should be installed only by a licensed electrician. Slow blow or time delay fuses or breakers should be used since the initial start-up time for the fan motor, although rare, can be up to 10 seconds. B. Motors: DANGER ALL WIRING CONNECTIONS, INSPECTION AND MAINTENANCE OF ANY MOTOR MUST BE PERFORMED BY A LICENSED ELECTRICIAN IN ACCORDANCE WITH THE MOTOR MANUFACTURERS RECOMMENDATIONS, ALL ELECTRICAL CODES AND OSHA REGULATIONS. FAILURE TO PROPERLY INSTALL, MAKE WIRING CONNECTIONS, INSPECT OR PERFORM ANY MAINTENANCE TO A MOTOR CAN RESULT IN MOTOR FAILURE, PROPERTY DAMAGE, EXPLOSION, ELECTRICAL SHOCK AND DEATH. 1. DO NOT connect or operate a motor without reading the motor manufacturers instructions supplied with the fan. The basic principle of motor maintenance is: KEEP THE MOTOR CLEAN AND DRY. This requires periodic inspections of the motor. The frequency of the inspections depends on the type of motor, the service and environment it will be subjected to and the motor manufacturers instructions. OMM page 5
6 2. Cleaning: Cleaning should be limited to exterior surfaces only. Follow motor manufacturers cleaning instructions. 3. Lubrication: Most small motors have sealed bearings that are permanently lubricated for the life of the motor. Some larger motors have grease plugs that should be replaced with grease fittings to perform re-lubrication. These motors, or any motor with grease fittings, should be lubricated in accordance with the motor manufacturers recommendations. Lubrication frequency depends on the motor horsepower, speed and service. BE SURE you use compatible grease and DO NOT over grease. 4. Location: A standard Open Drip Proof or Totally Enclosed type motor is suitable in a clean, dry location below 104 F. (40 C). If the location will be wet, dirty or reach temperatures above 104 F (40 C), a different type of motor may be necessary. Consult our local sales office for your area for proper motor selection assistance. All wiring must meet NEC (National Electric Codes) standards. 5. Wiring Connections: All wiring connections should be made for the proper voltage and phase as shown on the motor nameplate. Connections should follow the motor manufacturers recommendations as shown on the wiring schematic. This wiring diagram will be located on the outside of the motor, inside of the motor conduit box or on the motor nameplate. Reversing some wires might be necessary to get the correct fan rotation. 6. Motors with Thermal Overload Protection: If a motor is equipped with thermal overloads, the thermal overload must be wired per the wiring schematic to be operable. There are 3 types of thermal overloads: a. Automatic: These will automatically shut the motor down if the internal temperature exceeds the design limits. DANGER MAKE SURE YOU LOCK OUT THE POWER TO THE MOTOR BEFORE INSPECTING ANY MOTOR WITH AUTOMATIC THERMALS. WHEN THE THERMALS COOL DOWN, THEY WILL ALLOW THE MOTOR TO AUTOMATICALLY START UP AGAIN, UNLESS YOU HAVE LOCKED OUT THE POWER TO THE MOTOR. b. Manual: These motors will have a button on them. If the motor overheats, it will shut down. After you have inspected the motor and eliminated the over heating problem, you will need to reset it by pushing the button. You should still lock out the power BEFORE inspecting the motor. c. Thermostats: This type of thermal is a temperature sensing device ONLY. If the motor overheats, the thermostats will open or close (depending on the type) and send a signal to the electrical box. THEY WILL NOT TURN THE MOTOR OFF. These are pilot circuit devices that must be connected to the magnetic starter circuit. 7. EXPLOSION PROOF Motors: No motor is explosion proof. Explosion proof (EXP) motors are designed so if there is an explosion WITHIN the motor, the explosion will be CONTAINED INSIDE the motor and not allowed to get out to the atmosphere. All explosion proof motors must be selected based on the atmosphere and/or the environment the motor will be operating in. Explosion proof motors are designed, rated, and labeled for their operating conditions based on Classes, Groups and T Codes. The Class, Group and T Code of an EXP motor MUST be selected based on the atmosphere and/or environmental conditions the motor will be operating in. Consult the NEC (National Electric Code) and the NFPA (National Fire Protection Association) for the proper EXP motor Class, Group and T Code required for your specific application and location. OMM page 6 DANGER IF AN EXPLOSION PROOF MOTOR IS USED IN AN AREA CONTAINING VOLATILE LIQUIDS, GASES, FUMES OR DUST FOR WHICH THE MOTOR WAS NOT DESIGNED TO OPERATE IN, AN EXPLOSION AND/OR FIRE CAN OCCUR. NOTICE: a. All EXP motors have some type of thermal overload as required by UL (Underwriters Laboratories). Refer to all of Section 6 above. b. All EXP motors are required to have the UL (Underwriters Laboratories) and CSA (Canadian Standards Association) listing numbers on the motor name plate or on a separate plate attached to the motor. The Class, Group and T Code the motor is designed for must also be listed. 8. Normal Motor Operating Temperatures: Using your hand to test the normal running temperature of a motor can be a very painful experience; The normal operating temperature of a fully loaded, open type, electric motor operating in a 70 F. (21 C.) ambient temperature is 174 F. (79 C.)
7 C. Maximum Fan Speed and Motor Speed Controllers: If you will be using any type of motor speed controller with this fan, DO NOT exceed the maximum safe fan speed. Installing and using a speed control device requires special training and certification as required by the speed control manufacturer. See the manufacturers instructions for proper use, installation and wiring connections for the maximum speed settings. It may also be necessary to block out some speeds to eliminate a resonant vibration problem. The maximum safe fan speed is shown on the data sheet shipped with the fan. If you have lost the data sheet, contact Cincinnati Fan or our sales office for your area. You must have the serial number from the fan name plate for us to determine the maximum safe fan speed. Cincinnati Fan will only extend the motor manufacturers warranty, when used with a speed controlling device, if the motor has the words Inverter Duty marked on the motor name plate. If the motor does not have Inverter Duty marked on the motor name plate, and you have a motor failure, you will be required to contact the motor manufacturer for any service or warranty claims. IV. INITIAL UNIT STARTUP NOTICE: Failure to complete and document all the following pre-startup and both post-startup checks, listed in section A and B below, could void all warranties. A. Pre-Startup & Post-Startup Checks: (Check blocks as each step is completed. Retain this for your records.) A1. Pre-Startup Checks Completed By: DATE: A2. 8 Hour, Post-Startup Checks Completed By: DATE: A3. 24 Hour, Post-Startup Checks Completed By: DATE: MAKE SURE POWER TO THE MOTOR IS LOCKED OUT BEFORE STARTING PRE-STARTUP OR POST-STARTUP CHECKS. BEFORE MOUNTING FAN IN DUCT WORK OR ON A MACHINE: If you will be mounting this fan into a duct system, and there is no access door in the fan drum, it is strongly recommended that an access door be installed in the duct work section next to the fan. That will allow you access to perform the post-startup checks more easily. 1. Check the propeller by spinning it by hand to ensure it rotates freely. 2. Check the propeller set screws to make sure they are tight per Table 1 on page If the propeller has a taper-lock bushing, make sure the bolts are tightened per Table 2 on page Make certain there is no foreign material in the fan or duct work that can become a projectile. 5. Ensure all electrical power components are properly sized and matched for your electrical system. 6. Record the Full Load Amps listed on the motor nameplate. You will need to refer to this later. Low Voltage Amps: High Voltage Amps: AFTER MOUNTING FAN IN DUCT WORK OR ON A MACHINE: 7. Check all duct work hardware to make sure it is tight. 8. Make sure any inspection doors in the duct work are securely bolted or locked. 9. Check that any required guards are properly secured. 10. Any dampers or valves should be fully opened and closed to make sure there is no binding or interference. 11. If your fan is mounted on an elevated support structure, make sure the structure is welded at all the joint connections and the structure is properly braced to prevent any side sway. 12. Make sure the propeller is stationary prior to startup. Starting a fan with a prop that is rotating backwards can cause propeller damage. 13. Make the necessary wiring connections to the motor per National Electric Code (NEC) regulations. 14. Apply power to the fan motor momentarily (i.e. bump start ) to check for propeller fan rotation. If the fan is rotating in the wrong direction, reconnect the motor leads per the motor manufacturers wiring schematic. The fan rotation must match the rotation indicated by the rotation arrow decals on the outside of the fan drum. After reconnecting the leads, repeat this step. 15. Apply power to the fan motor and let it come up to full speed. Turn off the power. Listen for any unusual noise or mechanical abnormality while the propeller is still spinning. If any are noticed, lock out the power, wait for the propeller to come to a complete stop, locate the cause and correct it. 16. Unlock power and start the fan. 17. Measure, record and keep the following motor data for future reference and comparison. (Single phase motors will only have L1 and L2 leads.) Amperage draw on each motor lead: L1 L2 L3 (Running amps SHOULD NOT exceed the motor nameplate amps for the voltage being operated on). Compare these amp readings to the Full Load Amps you recorded in Step 6 above. Voltage coming to motor leads: L1 L2 L3 (Should be about the same input voltage on all leads). OMM page 7
8 18. Run fan for minutes to allow belts to seat properly. Then turn off and lock out power to the motor. 19. If the fan has a belt guard or weather hood, remove it at this time. WARNING: If fan will be running in an area where other people could come in contact with it, you will need to reinstall the motor cover or belt guard before performing steps 21, 23, 25, and Check belt tension. Alignment and tension should be as shown in Fig. 2 and Fig. 3 on page 10. Adjust if necessary. Then unlock power to the motor. 21. Run fan for 8 hours. Then turn off and lock out power to the motor. 22. Check belt tension as in step 20. Adjust if necessary. Then unlock power to the motor. 23. Run fan for 24 hours. Then turn off and lock out power to the motor. 24. Check belt tension as in step 20. Adjust if necessary. Then unlock power to the motor. 25. Run fan for 100 hours. Then turn off and lock out power to the motor. 26. Check belt tension as in step 20. Adjust if necessary. Then unlock power to the motor. 27. Run fan. Repeat these steps periodically, but never more than a one year period. B. Vibration: All props are balanced to comply with ANSI S2.19, G6.3. However, rough handling in shipment and/or erection, weak and/or non-rigid foundations, and misalignment may cause a vibration problem after installation. After installation, the vibration levels should be checked by personnel experienced with vibration analysis and vibration analysis equipment. V. ROUTINE INSPECTION & MAINTENANCE Periodic inspection of all the fan parts is the key to good maintenance and trouble-free operation. The frequency of inspections must be determined by the user and is dependent upon the severity of the application. BUT, it should NEVER exceed a 12 month period. The user should prepare an inspection and maintenance schedule and make sure it is adhered to. OMM page 8 WARNING BEFORE STARTING ANY INSPECTION OR MAINTENANCE, BE SURE FAN IS TURNED OFF, POWER IS LOCKED OUT AND THE PROPELLER HAS BEEN CAREFULLY SECURED TO PREVENT WIND MILLING. IF THE OPERATING CONDITIONS OF THE FAN ARE TO BE CHANGED (SPEED, PRESSURE, TEMPERATURE, ETC.) CONSULT CINCINNATI FAN, OR OUR SALES OFFICE FOR YOUR TERRITORY, TO DETERMINE IF THE UNIT WILL OPERATE SAFELY AT THE NEW CONDITIONS. A. Hardware: All fan hardware should be checked to make sure it is tight. All set screws or taper-lock bushing bolts should be tightened to the torque values shown in Tables 1 and 2 on page 4. NOTE: If any set screws have become loose, they must be thrown away and replaced. NEVER use set screws more than once. Replace with knurled, cup-point set screws with a nylon locking patch. B. Motor and Fan Bearing Lubrication: 1. Motor Bearings: Most smaller motors have sealed bearings that never require re-lubrication for the life of the motor. For any motors with grease fittings, consult the motor manufacturers recommendations with reference to the lubrication frequency and the type of grease that should be used. DO NOT over grease the motor bearings. Generally, 1-2 shots should be enough. Use a hand operated grease gun at no more than 40 PSI. IF POSSIBLE, CAREFULLY lubricate the motor bearings while the motor is running. 2. Fan Bearings: The fan bearings used in Model BAF fans are sealed-for-life bearings that require no additional lubrication for the life of the bearings. The bearings are pressed into the bearing housing and are held in place, on the fan shaft, with locking rings and Lock-Tite. If the bearings wear out, the entire shaft/bearings/bearing housing assembly should be replaced. The maximum airstream temperature for this fan is 175 F (79 C). C. Propeller Balance: All propellers are balanced at the factory. It is not uncommon that additional trim balancing is required after the fan is assembled. Trim balancing of the fan assembly, in the field, is typically always necessary for all replacement props. Airstream material or chemicals can cause abrasion or corrosion of the fan parts. This wear is generally uneven and, over time, will lead to the prop becoming unbalanced causing excessive vibration. When that happens, the prop must be rebalanced or replaced. The other airstream components should also be inspected for wear or structural damage and cleaned or replaced if necessary. After cleaning any prop, it should be balanced.
9 There are two ways to balance a propeller: 1. Add balancing weights for fabricated aluminum, steel or stainless steel props: Balance weights should be rigidly attached to the prop at a location that will not interfere with the fan housing nor disrupt air flow. They should (if at all possible) be welded to the prop. When trim balancing the propeller, on the fan shaft, be sure to ground the welder directly to the prop. Otherwise, the welding current will likely pass through the fan shaft and damage the fan and/or motor bearings. 2. Grinding off material for cast aluminum props: When grinding on the prop to remove material, be very careful not to grind too much in one area. That could affect the structural integrity of the prop. D. Vibration: As mentioned previously in this manual, excessive vibration can cause premature motor and/or fan bearing failure that could lead to catastrophic failure of the fan. After performing any routine maintenance, the vibration readings should be taken again. New readings should be taken (maximum every 12 months) and compared to the readings you previously recorded. If any major differences are present, the cause should be determined and corrected before the fan is put back into operation. The most common causes of vibration problems are: 1. Prop unbalance 4. Poor fan inlet and/or discharge conditions 2. Bearing failure 5. Foundation stiffness 3. Mechanical looseness 6. Misaligned sheaves and/or belts E. TO REPLACE THE BELTS ONLY ON ALL FAN SIZES. NOTE: You DO NOT need to remove the fan from the system. NOTE: BEFORE starting ANY maintenance or inspection, make sure the power to the fan motor is turned off and locked out in accordance with OSHA lock-out/tag-out procedures. Use this procedure anywhere in this manual when instructed to lock out power to the motor. NOTE: ANY MAINTENANCE OR INSPECTION SHOULD ONLY BE PERFORMED BY QUALIFIED, TRAINED MAINTENANCE PERSONNEL. 1. Lock out power to the motor. 2. Remove the belt guard or weather cover, if supplied. 3. The adjustable motor base is used to adjust the belt tension. Loosen the tension by first loosening the 4 locking bolts in the SIDE of the motor base assembly. DO NOT remove these bolts. 4. Now, turn the 4 tensioning bolts in the TOP of the motor base counter-clockwise so the motor base moves as close to the fan drum as possible. This will reduce the tension on the belts. 5. Remove the belt(s) from the motor sheave, and then the fan sheave. Remove the belt(s) from through the belt tube. 6. Slide the new belt(s) into the belt tube and into the fan sheave grooves. NOTE: If there is more than one belt, the belts should be a matched set. 7. Slide the belt(s) over the motor sheave and into the motor sheave grooves. DO NOT force, pry or roll the belt(s) as this can cause damage to the cords in the belt(s). 8. Since you have not moved the sheaves on the motor shaft and fan shaft and you have not changed the location of the motor on the motor base, the fan and motor sheaves should still be aligned with each other as shown in the Proper alignment block in Fig. 1 on page 5. You should still check it to make sure. 9. You WILL need to check that the motor shaft and fan shaft are parallel with each other as indicated in Fig. 1 on page 5. This will require you to check that the belts are perpendicular with the sheave grooves just by site. 10. Adjust the tension on the belts by turning the 4 tensioning bolts in the TOP of the motor base clockwise until the belts appear to be just snug 11. Re-check the sheave alignment and shaft parallelism again as you did in Steps 8 and Now tighten the 4 locking bolts in the SIDE of the motor base. USE EXTREME CAUTION WHILE PERFORMING THE FOLLOWING STEPS 13 and Unlock power to the motor and run the fan for 20 minutes. This will allow the belts to seat themselves in the sheave grooves 14. After 20 minutes, CAREFULLY look down the belt tube to observe if the belts are running as indicated in Fig. 3 on page Turn off and lock out power to the motor. 16a. If the belts were running as per Fig. 3 on page 10, re-install the belt guard or weather cover if supplied, then go to Step 17 16b. If the belts were NOT running as indicated in Fig. 3 on page 10, repeat Steps 2, 3, 10, 11, 12, 13, 14 and 16a above. 17. Unlock power to the motor and run the fan for 8 hours. 18. After running the fan for 8 hours, turn off and lock out power to the motor. 19. Remove the belt guard or weather cover, if supplied. OMM page 9
10 20. Unlock power to the motor and run the fan. 21. CAREFULLY look down the belt tube to observe if the belts are still running as indicated in Fig. 3 below. 22. Turn off and lock out power to the motor. 23a. If the belts ARE running as per Fig. 3 below, re-install the belt guard or weather cover if supplied, then go to Step b. If the belts ARE NOT running as indicated in Fig. 3 below, repeat Steps 2, 3, 10, 11, 12, 13, 14 and 16a on page Unlock power to the motor and run the fan for 24 hours. 25. After running the fan for 24 hours, turn off and lock out power to the motor. 26. Remove the belt guard or weather cover, if supplied. 27. Unlock power to the motor and run the fan. 28. CAREFULLY look down the belt tube to observe if the belts are still running as indicated in Fig. 3 below. 29. Turn off and lock out power to the motor. 30a. If the belts ARE running as per Fig. 3 below, re-install the belt guard or weather cover if supplied, then go to Step b. If the belts ARE NOT running as indicated in Fig. 3 below, repeat Steps 2, 3, 10, 11, 12, 13, 14 and 16a on page Unlock power to the motor and run the fan for 100 hours. 32. After running the fan for 100 hours, turn off and lock out power to the motor. 33. Remove the belt guard or weather cover, if supplied. 34. Unlock power to the motor and run the fan. 35. CAREFULLY look down the belt tube to observe if the belts are still running as indicated in Fig. 3 below. 36. Turn off and lock out power to the motor. 37a. If the belts ARE running as per Fig. 3 below, re-install the belt guard or weather cover if supplied, then go to Step b. If the belts ARE NOT running as indicated in Fig. 3 below, repeat Steps 2, 3, 10, 11, 12, 13, 14 and 16a on page Unlock power to the motor and run the fan. You should periodically check the belt tension but never less than once a year. Fig. 2 Fig. 3 Straight edge should touch sheaves at these 4 points. Straight Edge Too Tight Proper Tension (Slight Bow) Too Loose F. TO REPLACE THE BELTS, SHEAVES AND BEARING ASSEMBLY. NOTE: You MUST remove the fan from the system to complete the following steps. NOTE: If you need to replace both the belts AND the sheaves, you should also replace the fan shaft and bearing assembly at the same time. This will save you additional down time later. If the sheaves are worn, the shaft and bearings are generally worn also. The below instructions are for replacing the belts, sheaves and fan shaft/ bearing assembly. NOTE: BEFORE starting ANY maintenance or inspection, make sure the power to the fan motor is turned off and locked out in accordance with OSHA lock-out/tag-out procedures. Use this procedure anywhere in this manual when instructed to lock out power to the motor ANY MAINTENANCE OR INSPECTION SHOULD ONLY BE PERFORMED BY QUALIFIED, TRAINED MAINTENANCE PERSONNEL. 1A. Lock out power to the motor. 2A. Remove the belt guard or weather cover, if supplied. 3A. Disconnect the wiring from the power supply to the motor. 4A. While supporting the fan with a crane or hoist, unbolt the flanges that connect the fan to the duct work or machine. Save the hardware for later. 5A. Remove the fan drum and motor assembly from the duct work or machine to a work bench or on the floor. 6A. Set the fan down on the flanges, with the motor at the 12 O clock position. Brace the fan on both sides so it cannot roll. 7A. The adjustable motor base is used to adjust the belt tension. Loosen the tension by first loosening the 4 locking bolts in the SIDE of the motor base assembly. DO NOT remove these bolts. 8A. Now, turn the 4 tensioning bolts in the TOP of the motor base counter-clockwise so the motor base moves as close to the fan drum as possible. This will reduce the tension on the belts. OMM page 10
11 NOTE: There is a difference in the construction for 12 to some 24 fans and some 24 fans to 42. a. All size 12 to 18 fans have a solid back belt tube with NO access hole in the center. b. All size 24 fans, with 3/4 fan shafts have a solid back belt tube with NO access hole in the center. c. All size 24 fans, with 1 fan shafts have a belt tube WITH an access hole in the center d. All size 30 to 42 fans have a belt tube WITH an access hole in the center. On the fan sizes WITHOUT the access hole, you remove the belts from the end of the belt tube. On fan sizes WITH the access hole, remove the 4 screws in the cover plate to remove the cover plate from the belt tube. This will make it easier to remove the belts from the grooves of the sheaves on the larger fans with multiple belts. All other steps will be the same regardless of the fan size. 9A. Remove the belt(s) from the motor sheave, and then the fan sheave. 10A. Measure the location from the end of the motor shaft to the motor sheave. Keep this dimension for later. 11A. Remove the motor sheave from the motor shaft. DO NOT move the location of the motor on the motor base. 12A. Measure the location from the end of the fan shaft to the front of the propeller hub. Keep this dimension for later. 13A. Remove the set screws from the propeller or loosen the bolts from the taper-lock hub in the propeller. Throw set screws away. 14A. CAREFULLY remove the propeller from the fan shaft. 15A. Unbolt the bearing housing/shaft assembly from the belt tube flange. Save this hardware for later. 16A. Remove the fan shaft, bearing housing assembly from the belt tube flange. 17A. Measure the location from the end of the fan shaft to the fan sheave. Keep this dimension for later. 18A. Install a new fan sheave onto a new fan shaft / bearing housing assembly. Install the sheave at the same location on the shaft that you measured in Step 17A above. 19A. Tighten the set screws in the sheave or the bolts in the taper-lock bushing of the sheave. Tighten per Tables 1 or 2 on page 4. 20A. Install the new fan sheave and shaft / bearing housing assembly into the belt tube of the fan. 21A. Re-install the hardware you removed in Step 15A above to bolt the bearing housing to the belt tube flange. Tighten the bolts. 22A. CAREFULLY re-install the propeller onto the fan shaft. DO NOT pound the propeller hub with a hammer. 23A. Locate the propeller hub at the same position on the shaft that you measured in Step 12A above. 24A. Line up the keyway in the propeller hub with the keyway in the fan shaft and insert a new key. 25A. Insert new set screws into the hub of the propeller or replace the locking bolts into the taper-lock bushing of the propeller. 26A. Tighten the set screws in the propeller or the bolts in the taper-lock bushing of the propeller. Tighten per Tables 1 or 2 on page 4. 27A. Install a new motor sheave at the same location on the motor shaft that you measured in Step 10A above. 28A. Tighten the set screws in the sheave or the bolts in the taper-lock bushing of the sheave. Tighten per Tables 1 or 2 on page 4. 29A. Install new belt(s) into the belt tube and into the fan sheave grooves. 30A. Slide the belt(s) over the motor sheave and into the motor sheave grooves. DO NOT force, pry or roll the belts as this can cause damage to the cords in the belts. Re-install the belt tube access hole cover plate if available. 31A. Adjust the tension on the belts by turning the 4 tensioning bolts in the TOP of the motor base clockwise until the belts appear to be just snug. 32A. Now tighten the 4 locking bolts in the SIDE of the motor base. 33A. Since all the components were re-installed per the same original dimensions, they should still be aligned and parallel with each other as shown in Fig. 1 in page 5 and Fig. 2 on page 10. You should still check the belts to make sure they are aligned and the belts are perpendicular to the grooves in the sheaves. 34A. Re-install the fan into the duct system or onto the machine using the hardware you removed in Step 4A on page A. Re-connect power to the motor. 36A. Turn the power on just for 3-4 seconds, then turn the power off and observe that the fan is turning the proper rotation. 37A. If the fan IS NOT turning the proper rotation, lock out power to the motor and reconnect the leads. If the fan IS turning the proper rotation, go on to Step 38A. 38A. Unlock power to the motor and run the fan for 20 minutes. This will allow the belts to seat themselves in the sheave grooves. 39A. After 20 minutes, CAREFULLY look down the belt tube to observe if the belts are running as indicated in Fig. 3 on page A. Turn off and lock out power to the motor. 41A-a. If the belts ARE running as per Fig. 3 on page 10, re-install the belt guard or weather cover if supplied, then go on to Step 42A. 41A-b. If the belts ARE NOT running as indicated in Fig. 3 on page 10, repeat Step 2A on page 10 and Steps 31A, 32A and 33A above. OMM page 11
12 42A. Unlock power to the motor and run the fan for 8 hours. 43A. After running the fan for 8 hours, turn off and lock out power to the motor. 44A. Remove the belt guard or weather cover, if supplied. 45A. Unlock power to the motor and run the fan. 46A. CAREFULLY look down the belt tube to observe if the belts are still running as indicated in Fig. 3 on page 10. Turn off and lock out power to the motor. 47A-a. If the belts ARE running as per Fig. 3 on page 10, re-install the belt guard or weather cover if supplied, then go to Step 48A. 47A-b. If the belts ARE NOT running as indicated in Fig. 3 on page 10, repeat Step 2A on page 10 and Steps 31A, 32A and 33A on page A. Unlock power to the motor and run the fan for 24 hours. 49A. After running the fan for 24 hours, turn off and lock out power to the motor. 50A. Remove the belt guard or weather cover, if supplied. 51A. Unlock power to the motor and run the fan. 52A. CAREFULLY look down the belt tube to observe if the belts are still running as indicated in Fig. 3 on page A. Turn off and lock out power to the motor. 54A-a. If the belts ARE running as per Fig. 3 on page 10, re-install the belt guard or weather cover if supplied, then go to Step 55A. 54A-b. If the belts Are NOT running as indicated in Fig. 3 on page 10, repeat Step 2A on page 10 and Steps 31A, 32A and 33A on page A. Unlock power to the motor and run the fan for 100 hours. 56A. After running the fan for 100 hours, turn off and lock out power to the motor. 57A. Remove the belt guard or weather cover, if supplied. 58A. Unlock power to the motor and run the fan. 59A. CAREFULLY look down the belt tube to observe if the belts are still running as indicated in Fig. 3 on page A. Turn off and lock out power to the motor. 61A-a. If the belts ARE running as per Fig. 3 on page 10, re-install the belt guard or weather cover if supplied, then go to Step 62A. 61A-b. If the belts ARE NOT running as indicated in Fig. 3 on page 10, repeat Step 2A on page 10 and Steps 31A, 32A and 33A on page A. Unlock power to the motor and run the fan. You should periodically check the belt tension but never less than once a year. G. Dampers and Shutters: (Airflow control device) Turn off and lock out power to the fan motor. Any dampers or shutters should be periodically inspected to make sure all parts are still operable within their full range and there is no interference with any other damper or fan components. Any bearings or seals should be checked for their proper function. The manufacturers maintenance instructions should be followed. H. Safety Equipment & Accessories: It is the user s responsibility to make sure that all safety guards required by company, local, state and OSHA regulations are properly attached and fully functional at all times. If any guards become defective or non-functional at any time, the power to the fan MUST be turned off and locked out until complete repairs and/or replacements have been made, installed and inspected by authorized personnel. Any accessories used in conjunction with the fan should also be inspected to make sure they are functioning within their intended limits and design specifications. The manufacturer s maintenance manuals should be referred to for correct maintenance procedures. These accessories include, but are not limited to, the following: Shaft seals, inspection doors, vibration isolators or vibration bases, air flow or pressure measuring equipment, hoods, controls, special coatings, silencers, expansion joints or flexible connectors, and filters. VI. ORDERING REPLACEMENT PARTS: Under normal conditions, you should not need any spare or replacement parts for at least 24 months after shipment from Cincinnati Fan. That does not include any wear due to abrasion, corrosion, excessive temperatures, abuse, misuse, accident or any severe conditions the fan was not designed for. A. If this fan is vital to any process that could cost you lost revenue, we strongly recommend that you keep a fan propeller, shaft and bearing assembly, motor, sheaves and belt(s) at your location. B. If this fan is vital for the safety of any people and/or animals, we strongly recommend that you keep a complete fan/motor assembly, as originally ordered, at your location. To order any parts or complete units, contact us for the name of our sales office for your area. Or you can find them on our website at: WE MUST HAVE THE FAN SERIAL NUMBER FROM THE FAN NAME PLATE TO IDENTIFY PARTS CORRECTLY. OMM page 12
13 VII. TROUBLESHOOTING: Potential problems and causes listed below are in no order of importance or priority. The causes are only a list of the most common items to check to correct a problem. If you find the cause of a problem, DO NOT assume it is the ONLY cause of that problem. Different problems can have the same causes. DANGER Troubleshooting should only be performed by trained personnel. Any potential electrical problems should only be checked by a licensed electrician. All safety rules, regulations and procedures MUST be followed. Failure to follow proper procedures can cause property damage, severe bodily injury and death. OMM page 13
14 VIII. LONG TERM STORAGE INSTRUCTIONS: (Storage exceeding 30 days after receipt of equipment) NOTE: Failure to adhere to these instructions voids all warranties in their entirety. 1. Storage site selection: (a) Level, well-drained, firm surface, in clean, dry and warm location. Minimum temperature of 50 F (10 C). (b) Isolated from possibility of physical damage from construction vehicles, erection equipment, etc. (c) Accessible for periodical inspection and maintenance. 2. The fan should be supported under each corner of its base to allow it to breathe. Supports (2 x 4 s, timbers, or railroad ties) should be placed diagonally under each corner. 3. If the equipment is to be stored for more than three (3) months, the entire fan assembly must be loosely covered with plastic, but not tightly wrapped. 4. Initial inspections must be made of the fan components, and immediate corrective action taken if discrepancies are found, to insure adequate protection of the equipment during storage. (a) Sheave center distance should be reduced to reduce tension on the belts. 5. Storage Maintenance: A periodic inspection and maintenance log, by date and action taken, must be developed and maintained for each fan. See example below. Each item must be checked monthly. EXAMPLE: Storage / Maintenance Schedule Log 6. General Motor Procedure: If the motor is not put into service immediately, the motor must be stored in a clean, dry, warm location. Minimum temperature of 50 F. (10 C,). Several precautionary steps must be performed to avoid motor damage during storage. a. Use a Megger each month to ensure that integrity of the winding insulation has been maintained. Record the Megger readings. Immediately investigate any significant drop in insulation resistance. b. DO NOT lubricate the motor bearings during storage. Motor bearings are packed with grease at the factory. Excessive grease can damage the insulation quality in the motor. c. If the storage location is damp or humid, the motor windings must be protected from moisture. This can be done by applying power to the motor s space heaters, (IF AVAILABLE) while the motor is in storage. If the motor does not have space heaters, storing it in a damp or humid location will, very quickly, cause internal corrosion and motor failure which is not warranted. d. Rotate motor shaft a minimum of 10 full turns each month to keep bearing grease from separating and drying out. NOTE: For specific storage instructions, for the actual motor and any accessory parts that were supplied, refer to the manufacturer s instructions. OMM page 14
15 IX. LIMITED WARRANTY: Cincinnati Fan & Ventilator Company (Seller) warrants products of its own manufacture, against defects of material and workmanship under normal use and service for a period of eighteen (18) months from date of shipment or twelve (12) months from date of installation, whichever occurs first. This warranty does not apply to any of Seller s products or any part thereof which has been subject to extraordinary wear and tear, improper installation, accident, abuse, misuse, overloading, negligence or alteration. This warranty does not cover systems or materials not of Seller s manufacture. On products furnished by Seller, but manufactured by others, such as motors, Seller extends the same warranty as Seller received from the manufacturer thereof. Expenses incurred by Purchaser s in repairing or replacing any defective product will not be allowed except where authorized in writing and signed by an officer of the Seller. The obligation of the Seller under this warranty shall be limited to repairing or replacing F.O.B. the Seller s plant, or allowing credit at Seller s option. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS AND LIABILITIES OF THE SELLER. THE PURCHASER ACKNOWLEDGES THAT NO OTHER REPRESENTATIONS WERE MADE TO PURCHASER OR RELIED UPON BY PURCHASER WITH RESPECT TO THE QUALI- TY OR FUNCTION OF THE PRODUCTS HEREIN SOLD. Removal of the Sellers nameplate or any generic fan nameplate containing the fan serial number voids all warranties, either written or implied. Failure to complete and document all the pre-startup and post startup checks and perform the suggested routine maintenance checks voids all warranties, either written or implied. LIMITATION OF LIABILITY: Notice of any claim, including a claim for defect in material or workmanship, must be given to Seller in writing within 30 days after receipt of the equipment or other products. Seller reserves the right to inspect any alleged defect at Purchaser s facility before any claim can be allowed and before adjustment, credit, allowance replacement or return will be authorized. See RETURNS below. Seller s liability with respect to such defects will be limited to the replacement, free of charge, of parts returned at Purchaser s expense F.O.B. Seller s plant and found to be defective by the Seller. IN NO EVENT WILL SELLER BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTACT, TORT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE, INCLUDING WITHOUT LIMITATION DAMAGES FOR INJURY TO PERSONS OR PROPERTY, LOST PROFITS OR REVENUE, LOST SALES OR LOSS OF USE OF ANY PRODUCT SOLD HEREUNDER. PURCHASER S SOLE AND EXCLUSIVE REMEDY AGAINST SELLER WILL BE THE REPLACEMENT OF DEFECTIVE PARTS AS PROVIDED HEREIN OR REFUND OF THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS, AT SELLER S SOLE OPTION. SELLER S LIABILITY ON ANY CLAIM, WHETHER IN CONTRACT, TORT, NEGLIGENCE, STRICT LIABILITY OR OTHERWISE, FOR ANY LOSS OR DAMAGE ARISING OUT OF OR IN CON- NECTION WITH PURCHASER S ORDER OR THE PRODUCTS OR EQUIPMENT PURCHASED HEREUNDER, SHALL IN NO CASE EXCEED THE PURCHASE PRICE OF THE EQUIPMENT GIVING RISE TO THE CLAIM. RESPONSIBILITY: It is the understanding of the Seller that Purchaser and/or User will use this equipment in conjunction with additional equipment or accessories to comply with all Federal, State and local regulations. The Seller assumes no responsibility for the Purchaser s and/or User s compliance with any Federal, State and local regulations. RETURNS: Cincinnati Fan & Ventilator Company assumes no responsibility for any material returned to our plant without our permission. An RMA (Return Material Authorization) number must be obtained and clearly shown on the outside of the carton or crate and on a packing slip. Any items returned must be shipped freight prepaid. Failure to comply will result in refusal of the shipment at our receiving department. DISCLAIMER This manual, and all its content herein, is based on all applicable known material at the time this manual was created. Any parts of this manual are subject to change at any time and without notice. If any statements, diagrams and/or instructions contained herein, for components not manufactured by the Seller, conflict with instructions in the manufacturer s manual (i.e.: motors, bearings, belts and sheaves, dampers, etc.), the instructions in the manufacturer s manual, for that component take precedent. Should you want the latest version of this manual, please contact us or our sales office for your area. Or, you can print a current version by going to our website at: Snider Road, Mason, OH Phone: (513) Fax: (513) [email protected] OMM page 15
16 X. PARTS DRAWING: PLEASE NOTE Cincinnati Fan manufactures many models and arrangements with special variations. For that reason, the maintenance manuals contained on our website do not include a parts drawing nor the completed blower or fan specifications on page 1. For the parts drawing of all the standard components and specifications for the specific blower or fan that you have, please contact our local Cincinnati Fan sales office for your area. You will need to give them the serial number shown on the blower or fan nameplate so they can supply you the correct information. Click on Contact a Sales Rep on our website for the name and contact information for our local sales office for your area. OMM page 16
SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: [email protected]
ATS Overhead Table Shelf System INSTRUCTION MANUAL
ATS Overhead Table Shelf System INSTRUCTION MANUAL ATS Overhead Table Shelf System Instruction Manual Warranty Newport Corporation warrants this product to be free of defects in material and workmanship
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013
ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013 READ CAREFULLY These instructions are intended to cover good practices in
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
IMPORTANT SAFETY RULES TO FOLLOW
WARNING FLOOR & CARPET CLEANER Any piece of equipment can be dangerous if not operated properly. YOU are responsible for the safe operation of this equipment. The operator must carefully read and follow
Vehicle Restraint Installation Manual
Vehicle Restraint Installation Manual SHR-5000 9 Carriage SHR-5000 12 Carriage MADE IN U.S.A. This Manual Covers Restraints Built After Serial Numbers: 4487000001 and up PRINTED IN U.S.A. RITE-HITE PRINT
SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor
INSTALLATION, OPERATION AND MAINTENANCE MANUAL For SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor Yeomans Chicago Corporation 3905 Enterprise Court P.O. Box 6620 Aurora, IL 60598-0620 Phone:
Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.
Name of Equipment Silver King Model SKMCD1P/C1 This equipment chapter is to be inserted in the appropriate section of the Equipment Manual. Manufactured exclusively for McDonald s By Silver King Refrigeration,
SINGLE STAGE INLINE FIRE PUMP
MODEL 383 SINGLE STAGE INLINE FIRE PUMP INSTRUCTION AND REPAIR MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains
PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N 10-1008-167
PROAIR Water-Cooled Air Conditioner CR43WC Model INSTRUCTION MANUAL Rev. E 2013 Pentair Technical Products P/N 10-1008-167 87976466 TABLE OF CONTENTS HANDLING & TESTING THE AIR CONDITIONER...3 INSTALLATION
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
PALLET JACK - 2.5 TON
PALLET JACK - 2.5 TON 39939 SET UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury.
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Table of Contents WARNING SYMBOLS AND DEFINITIONS
Table of Contents SAFETY INSTALLATION OPERATION MAINTENANCE Safety... 2 Specifications... 4 Installation... 5 Operation... 8 WARNING SYMBOLS AND DEFINITIONS Maintenance... 9 Parts List and Assembly Diagram...
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
IMPORTANT SAFETY NOTICE
IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds
LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page 2-7. 3-Phase Simplex Page 8-13
CONTROL PANEL INSTALLATION INSTRUCTIONS Single Phase Simplex Page 2-7 3-Phase Simplex Page 8-13 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions
Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF
Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/19/2012 PHONE: 800-444-1508 P.O. Box 200, Lewis Center, Ohio 43035-0200 FAX: 800-255-5314 740-548-7298 E-mail: [email protected]
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE
Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
12V Portable Diaphragm Compressor Operating and Maintenance Instructions
12V Portable Diaphragm Compressor Operating and Maintenance Instructions (Part No. DC2) Part No. Serial Number Date Purchased Table of Contents Page Safety Messages...2 Guidelines for Product Use...2 Operation
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL
ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER TABLE OF CONTENTS: INSTALLATION USE & CARE MANUAL IMPORTANT INFORMATION Assembly Instructions 2 Wiring Instructions 2 Outdoor Installation
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
Packaged Terminal Air Conditioner Wall Sleeve Installation
Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual
IEC Three Phase AC Motors (Aluminum Frame) Installation & Operating Manual 7/09 MN301 Table of Contents Section 1 General Information.................................................. 1-1 Overview........................................................
6 & 12 Volt Battery and Systems Tester with 100 Amp Load
6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12
Electric Panel Pump Control System. Operation, Maintenance and Installation Manual
Manual No. 5EP-OM1-1 Electric Panel Pump Control System Operation, Maintenance and Installation Manual INTRODUCTION... 1 RECEIVING AND STORAGE... 1 DESCRIPTION OF OPERATION... 1 INSTALLATION... 2 SEQUENCE
Owner s Manual Gantry Cranes
Owner s Manual Gantry Cranes Fixed Height Gantry Crane MODEL NUMBER: SERIAL NUMBER: CAPACITY IN TONS: Telescoping Gantry Crane Bushman AvonTec 262-790-4200, 800338-7810, Fax 262-790-4200 www.bushmanavontec.com
Wilo SP Series Submersible Sump Pumps ECS. ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions
Wilo SP Series Submersible Sump Pumps ECS ECS19-15.25 ECS22-15.33 ECS24-15.50 Installation and operating instructions PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can
1 Ton Telescoping Gantry Crane
1 Ton Telescoping Gantry Crane 41188 Gantry Crane Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. When unpacking, make sure that the product
Trouble Shooting. Pump
Trouble Shooting Pump Trouble Possible Cause Remedy Oil leaking in the area of water pump crankshaft Worn crankshaft seal, bad bearing, grooved shaft, or failure of retainer o-ring. Excessive play on crankshaft
WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581
sound proof AIr CoMprEssor CAbInEt owner's MAnuAl spc03 WWW.CALIFORNIAAIRTOOLS.COM Customer Support 1-866-409-4581 TAbLe OF CONTeNTS INTROduCTION IntroductIon 2 Important Safety InStructIonS 5 components
Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075
Part No. 89047 Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075 Cincinnati, OH 45241-4807 USA ELECTRIC FRYER SAFETY PRECAUTIONS Installation
Installation Manual Version 7.3 IMPORTANT:
Installation Manual Version 7.3 IMPORTANT: READ ENTIRE MANUAL CAREFULLY, THIS PHASE CONVERTER MUST BE INSTALLED BY A INDUSTRIAL LICENSED ELECTRICIAN 230 VOLTS MODEL ONLY READ FIRST!!!!!! DANGER: HIGH VOLTAGE
Owner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!
Heaters for the Harshest Environments Owner s Manual ISO 9001 EFX Explosion-Proof Exhaust Fan This manual covers installations, maintenance, repair and replacement parts. WARNING! READ ALL IMPORTANT NOTICES
INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
INSTRUCTION MANUAL IM042 Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS TABLE OF CONTENTS SUBJECT PAGE Safety Instructions... 3 Descriptions and Specifications...
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family
Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family Part of the Kiva Lighting Family Custom Lighting and Fans Since 1992 1312 12th St NW Albuquerque,
TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation
GTRDD SERIES HEATLESS DRYER INSTALLATION, OPERATION & MAINTENANCE MANUAL TABLE OF CONTENTS SECTION 1 General Information: Pg 2 Description of Operation SECTION 2 Safety Instructions: Pg 3 Installation
SE-100-1, SE-200-1, SE-500-1, and SE-1000-1 AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81) 83 54 10 18 ventas@industrialmagza.
AIR CHAMP PRODUCTS User Manual SE BRAKE MODELS: SE-00-, SE-200-, SE-500-, and SE-000- (i) FORM NO. L-20084-E-040 In accordance with Nexen s established policy of constant product improvement, the specifications
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
1/3 HP Submersible Sump Pump with Vertical Float Switch
1/3 HP Submersible Sump with Vertical Float Switch Item 68476 Specifications Float Switch Operation Height 7.1 IN. ON / 2.8 IN. OFF Electrical Requirements 120V~ / 60Hz / 7.6A Power Length Maximum Capacity
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Retractable Screen. Replacement Screen Instructions
Retractable Screen Patent Pending Replacement Screen Instructions For RTS, RET, & RTM Products ATTENTION! Retractable screens are not intended to provide security or provide for the retention of objects,
MODEL G300 BRAKE BLEEDER
MODEL G300 BRAKE BLEEDER Installation, Operation & Repair Parts Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV060616 P/N: 81-0035G 1 THIS PAGE INTENTIONALLY
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Ceiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
T-Series Air Conditioner T62 Model
INSTRUCTION MANUAL T-Series Air Conditioner T62 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
Series 30000 Hose Reels
Operating Instructions and Parts List for Series 30000 Hose Reels - MANUAL DRIVEN - - POWER DRIVEN - SAFETY PRECAUTIONS Personal injury and/or equipment damage may result if proper safety precautions are
Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.
1.0 IMPORTANT RECEIVING INSTRUCTIONS Visually inspect all components for shipping damage. Shipping Damage is not covered by warranty. If shipping damage is found, notify carrier at once. The carrier is
Mini-led spotlight with magnetic base
Mini-led spotlight with magnetic base Model 95799 Assembly And Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission
Tri-Homo Style Operation and Maintenance Instructions
Tri-Homo Style Operation and Maintenance Instructions One Research Drive Stratford, CT 06615 (203) 375-0063 www.sonicmixing.com 1 Installation and Start-up Do not perform following adjustments without
Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada 1-888-845-7330
All about the Use & Care of your Iron Important Safeguards... 2 Iron Safety Instructions... 3 Parts and Features...4 TA B L E O F C O N T E N T S Using Your Iron...6 Cleaning and Maintenance... 8 Warranty...9
OWNER S MANUAL Table Tennis Table Patent Pending
OWNER S MANUAL Table Tennis Table Patent Pending Be sure to write your model number and serial number here for future reference. You can find these numbers printed on the bottom of the table. MODEL # T8179
T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200
INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U
Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U SURT192RMXLBP2 SURT192RMXLBP2J English 990-2485B 02/2009 Introduction About this UPS The American Power Conversion (APC ) SURT192RMXLBP2 external
Threaded Inline Air Heaters
Threaded Inline Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow
! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)
Series 150S and 157S (Snap Switch, All Models except 157S-RB-P) Low Water Cut-Off/Pump Controllers For Steam Boilers and Other Level Control Applications McDonnell & Miller Installation & Maintenance Instructions
STC 3S012-020-A Series Solenoid Valves
STC 3S012-020-A Series Solenoid Valves 3S012-020-A Series Solenoid Valve Specifications Valve Model 3S012-1/8-A 3S012-1/4-A 3S020-1/8-A 3S020-1/4-A Port Size (NPT) 1/8 1/4 1/8 1/4 Valve Type Action 3 Way,
Miami Heat Pump HP Series Installation Guide
CAUTION- THIS UNIT IS FOR INDOOR USE ONLY!! WARNING BEFORE ANY INSTALLATION OR MAINTANCE IS STARTED PLEASE READ COMPLETE INSTLLATION GUIDE. INSTALLATION START-UP AND SERVICE INSTRUCTION- The HP Water Source
1100 LB. ELECTRIC HOIST
1100 LB. ELECTRIC HOIST 93251 ASSEMBLY AND OPERATING INSTRUCTIONS Jib Boom not included. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may
Park 250 Brushless Outrunner Instructions
Park 250 Brushless Outrunner Instructions Thank you for purchasing the E-flite Park 250 Brushless Outrunner motor. This motor is ideal for 3D models 4-6 oz (115-170g), and sport and scale models 6-12 oz
Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger
Digital echo-charge Owner s Manual Xantrex Digital echo-charge Battery Charger Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
Electric Hoist 44006
440 lb./ 880 lb. Electric Hoist 44006 SET UP AND OPERATING INSTRUCTIONS Distributed exclusively by Harbor Freight Tools. 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: http://www.harborfreight.com
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
LT SERIES User s Manual
LT SERIES User s Manual 1 - LT Series Operations Manual TABLE OF CONTENTS Specifications... 2 Introduction... 3 LT Series Models... 4 Optional Features... 4 Getting Started... 5 Installation... 5 Registration...
Installation Instructions
85-3976 rev. 05 08-13 Installation Instructions Thank you for purchasing this antisway bar kit. Please read through these instructions before installation. Rear Anti-Sway Bar Kit for Dodge Ram Pick-Up
Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty
Oceanscience Cable Chimp II Cableway ROV System User Guide and Warranty Page 1 Table of Contents Introduction Page 3 Overview Page 3 Setup and Operation Page 5 Remote Control Page 6 Power Management Page
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
Power Max Level 2 Charging Station en Installation and Operating Instructions This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608
Electric Water Heater OWNER S MANUAL FORCE 10 MARINE COMPANY 23080 HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) 522-0233 FAX: (604) 522-9608 If your water Heater is Damaged or you have questions
Owner s Guide and Installation Manual. Vancouver Model Name. 21321, 21328 Model No. English Español
For Your Records and Warranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. Vancouver Model Name 21321, 21328 Model No. Type A Models Owner s Guide and Installation
DBF 4XL Dryer Booster Fans
Installation and Operation Manual Item #: 401315 Rev Date: 121514 DBF 4XL Dryer Booster Fans DBF4XL Kit Includes: Dryer Booster Fan, 1 pc Fan Mounting Bracket and Hardware, 1 pc Wall Label (Mount on wasll
BRAKE DRUM AND ROTOR SERVICE INFORMATION
SERVICE INFORMATION To achieve maximum drum life and optimum performance, proper brake maintenance and brake balance are essential. Consult your truck or trailer manufacturer s maintenance manual for proper
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
HYDRAULIC TABLE CART
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE
Eemax Inc., 353 Christian Street, Oxford, CT 06478 1 E ema X SERIES 12-600 VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE WARNING
TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER
TWIN EAGLES, INC. Defining the Art of Outdoor Cooking TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER OWNER S MANUAL MODEL TEEH-1512 TEEH-2524 TEEH-3524 NEED ASSISTANCE? PLEASE CALL: (562) 802-3488 This
Digital Fingerprint safe
Digital Fingerprint safe Model 96846 Operation Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product
UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1
KNOXVILLE, TENNESSEE SECTION 16050 PAGE 1 PART 1 - GENERAL 1.01 RELATED DOCUMENTS: SECTION 16050 A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
KS Vertical In-Line Pump
KS Vertical In-Line Pump 302-032 Installation, Operation & Maintenance Manual SUPERSEDES: July 1, 2010 EFFECTIVE: August 1, 2012 Plant ID No. 001-1014 SAFETY REQUIREMENTS 1. IMPORTANT! These instructions
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
Owner s Manual & Safety Instructions
Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s
Instructions and precautions. Fork Height. Visit our website at: http://www.harborfreight.com
Pallet Jack Item 68760 / 68761 Instructions and precautions Specifications Capacity Control Lever Fork Height Fork Length Fork Width Maximum Minimum Width over Forks Steering Wheel Dia. 2-1/2 Ton (5,000
cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.
- Easy -wire installation with no external spark box necessary, but can be used with one. - Precision CNC machining and hand assembled construction. This is a premium product. - Accurate super hot spark
Multi-Pitch Pitching Machine USER MANUAL
Multi-Pitch Pitching Machine USER MANUAL TABLE OF CONTENTS Thank you for purchasing the Cimarron Multi-Pitch Pitching Machine. The Cimarron Multi-Pitch Pitching Machine is a high performance pitching machine
Drive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center