CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X



Similar documents
Z-TRAUQ INC. Tel.: (450) Fax: (450)

0.84" x 2.00" Z-TRAUQ INC. Tel.: (450) Fax: (450) z-trauq@qc.aira.com SPLIT CORE CURRENT TRANSFORMER MODEL 1SP.

AZ420 MINIATURE GENERAL PURPOSE RELAY

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

4 Posiflow Proportional Solenoid Valves

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Solid State Timers Type F

Tips for connecting 24-volt power

Distribution Dry Type Transformers

8146/5 Series Breaker Panelboards

DS 600. A contact free flux gate based current measurement sensor 600A rms

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

LOW-VOLTAGE CURRENT TRANSFORMERS

Centro-Matic Automatic Lubrication Systems System Controls

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Tape Wound, Split Core and Ebony Current Transformers

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

12V Dimmable Driver EL-TMDRVR

Temperature sensor with integrated transmitter for industrial applications, MBT 3560


Voltage Regulator SPAU 341 C. Product Guide

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Safety technique. Emergency stop module BO 5988 safemaster

36T Series Snap-Action Temperature Controls

Vario-Series Accessories

RM4TG20 three-phase network control relay RM4-T - range V

T Substation Maintenance and Commissioning Test Equipment

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Positronic Provides Complete Capability

mpm DIN CONNECTORS

Kuhlman Electric Corporation Volt Instrument Transformers

Current transformers (CT) & Shunts

SX460. Generator Automatic Voltage Regulator Operation Manual

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Catalog HY /US SERIES DESCRIPTION PAGE NO. SUPER COILS CC... 1/2 Solenoid Tubes... CE3-CE4 CA... 5/8 Solenoid Tubes...

FEATURES BODY DIA. MAX. Type M AWG 30: [0.254] Type C AWG 28: [0.320] Type T AWG 30: [0.254]

Current Transformers. Bonneville Power Administration. Steve Laslo For the Hands On Relay School (3-12) Revision 1.1. February 21,

Custom Products. Magnetic Components. Vishay Dale.

keep your measure under control

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Low Voltage Transformers Sealed, General Purpose, Dry Type

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Tape Wound, Split Core and Ebony Current Transformers

IEC Connectors. Introduction

Generator DoCKInG StatIonS

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

VSO MAX HP High Flow Proportional Valve

5 Non-Ventilated Automation Transformers

Analog signal converters CC-E I/I Current / current isolators

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Automatic Voltage Regulator User s Manual

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

AmphenolR. Now you're connected!

Industrial Control Power Transformers

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Using Current Transformers with the 78M661x

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

5 Non-Ventilated Automation Transformers

Enhanced Quality with a Touch of Style

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Transformers from 25va to 500kva. Standard despatch in days not weeks

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Pow-R-Con Multi Function Control

Control Devices Catalogue. Control Devices. Preferred and Standard Products

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

DC-DC Converter Module

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Catalog C-004 Rev. F

Voltage Loss Formula s

Absolute Rotary Encoder E6CP

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Three-phase monitoring relay CM-PFE

Life Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Problem / Solution. The problem:

The Different Types of AC Power Connectors in North America

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

100% EMI Emission Containment

Transcription:

CURRENT TRANSFORMER MODEL 546 1.10" I.D. PAGE No 1-38 REV 15DEC00 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" Ø0.22 (4 PLACES) 2.56 6 1.10 2.77 1 X 2.50 3.00 OPTIONAL B546 MOUNTING BRACKET OPTIONAL 635 MOUNTING PLATE NOTE: 1) ALL DIMENSIONS IN INCHES 2) ALL DIMENSIONS REF ONLY Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for all ratios Insulation voltage class is 0.6KV BIL 10KV Reference documents IEEE C57.13, UL1244, and IEC 44-1 Enclosure is glass-filled nylon, color is black Optional plate is XX phenolic, optional bracket is steel For indoor applications only Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575, 5.0, and 10 VAC output at F.S. primary amperage. Other non - standard ratings also available., 0.2, and 0.1 A output at F.S. primary amperage. Other nonstandard ratings also available 8-32 Brass Stud Terminals or #16 AWG UL 1015 Lead Wires Custom lead wire lengths and types Thermal ratings above 1.33 for selected ratios. Center tap and custom multi tap winding arrangements

1.10" I.D. PAGE No 1-39 CURRENT TRANSFORMER MODEL 546 REV 15DEC00 TYPICAL EXCITATION CURVE for MODEL 546 at 60HZ 10 1 10 0 INDUCED VOLTAGE (volt) 10-1 10-2 300:5A 400:5A 250:5A 150:5A 100:5A 200:5A 125:5A 75:5A 50:5A 60:5A 10-3 10-4 10-4 10-3 10-2 10-1 10 0 10 1 EXCITING CURRENT (amp) NUMBER * 546-050-00-xxx 546-060-00-xxx 546-075-00-xxx 546-100-00-xxx 546-125-00-xxx 546-150-00-xxx 546-200-00-xxx 546-250-00-xxx 546-300-00-xxx 546-400-00-xxx RATIO 50:5A 60:5A 75:5A 100:5A 125:5A 150:5A 200:5A 250:5A 300:5A 400:5A ACCURACY @ 60HZ, pf = 0.95 ± % BURDEN (VA) 3.0 2.5 4.0 5.0 7.5 10 15 NOMINAL WINDING RESISTANCE (ohm) 0.007 0.008 0.01 0.02 0.025 0.03 0.04 0.052 0.062 0.083 * "xxx" describes termination: "T" FOR BRASS STUDS, "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

CURRENT TRANSFORMER MODEL 636 1.10" I.D. PAGE No 1-50 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #20 AWG LEAD WIRE, STANDARD LENGTH IS 24" Ø0.22 (4 PLACES) 2.56 6 1.10 2.77 1 X 2.50 3.00 OPTIONAL B546 MOUNTING BRACKET OPTIONAL 635 MOUNTING PLATE NOTE: 1) ALL DIMENSIONS IN INCHES 2) ALL DIMENSIONS REF ONLY Specifications Secondary sources 0.1 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for all ratios Insulation voltage class is 0.6KV BIL 10KV For indoor applications only Reference documents IEEE C57.13, UL1244, CSA CAN3-C13-M83, and IEC 44-1 Enclosure is glass-filled nylon, color is black Optional plate is XX phenolic, optional bracket is steel Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575, 5.0, and 10 VAC output at F.S. primary amperage. Other non - standard ratings also available. 5, 1, and 0.2 A output at F.S. primary amperage. Other nonstandard ratings also available 8-32 Brass Stud Terminals or #20 AWG UL 1015 Lead Wires Custom lead wire lengths and types Thermal ratings above 1.33 for selected ratios. Center tap and custom multi tap winding arrangements

1.10" I.D. PAGE No 1-51 CURRENT TRANSFORMER MODEL 636 TYPICAL EXCITATION CURVE for MODEL 636 at 60HZ 10 3 10 2 INDUCED VOLTAGE (volt) 10 1 10 0 10-1 400:0.1A 250:0.1A 200:0.1A 100:0.1A 300:0.1A 125:0.1A 50:0.1A 150:0.1A 60:0.1A 75:0.1A 10-2 10-5 10-4 10-3 10-2 10-1 10 0 EXCITING CURRENT (amp) NUMBER * 636-050-02-xxx 636-060-02-xxx 636-075-02-xxx 636-100-02-xxx 636-125-02-xxx 636-150-02-xxx 636-200-02-xxx 636-250-02-xxx 636-300-02-xxx 636-400-02-xxx RATIO 50:0.1A 60:0.1A 75:0.1A 100:0.1A 125:0.1A 150:0.1A 200:0.1A 250:0.1A 300:0.1A 400:0.1A ACCURACY @ 60HZ, pf = 0.95 ± % BURDEN (ohm) 20 30 50 100 175 275 500 750 1150 1600 NOMINAL WINDING RESISTANCE (ohm) 5.9 7.1 9.1 20 25 30 40 65 80 160 * "xxx" describes termination: "T" FOR BRASS STUDS, "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

CURRENT TRANSFORMER MODEL 635 1.10" I.D. PAGE No 1-48 TERMINAL OPTION LEAD WIRE OPTION 1.10 0 1.20 2.55 3.00 3.47 0.18 x 0.31 SLOT ( 2 PLACES) 8-32 BRASS STUD (2 PLACES) UL1015 #18 AWG LEAD WIRE, STANDARD LENGTH IS 24" Ø0.22 (4 PLACES) 2.56 6 1.10 2.77 1 X 2.50 3.00 OPTIONAL B546 MOUNTING BRACKET OPTIONAL 635 MOUNTING PLATE NOTE: 1) ALL DIMENSIONS IN INCHES 2) ALL DIMENSIONS REF ONLY Specifications Secondary sources 1 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for all ratios Insulation voltage class is 0.6KV BIL 10KV For indoor applications only Reference documents IEEE C57.13, UL1244, CSA CAN3-C13-M83, and IEC 44-1 Enclosure is glass-filled nylon, color is black Optional plate is XX phenolic, optional bracket is steel Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575, 5.0, and 10 VAC output at F.S. primary amperage. Other non - standard ratings also available. 5, 0.2, and 0.1 A output at F.S. primary amperage. Other nonstandard ratings also available 8-32 Brass Stud Terminals or #18 AWG UL 1015 Lead Wires Custom lead wire lengths and types Thermal ratings above 1.33 for selected ratios. Center tap and custom multi tap winding arrangements

1.10" I.D. PAGE No 1-49 CURRENT TRANSFORMER MODEL 635 TYPICAL EXCITATION CURVE for MODEL 635 at 60HZ 10 2 10 1 INDUCED VOLTAGE (volt) 10 0 10-1 400:1A 200:1A 250:1A 100:1A 300:1A 125:1A 50:1A 150:1A 60:1A 75:1A 10-2 10-3 10-5 10-4 10-3 10-2 10-1 10 0 EXCITING CURRENT (amp) NUMBER * 635-050-01-xxx 635-060-01-xxx 635-075-01-xxx 635-100-01-xxx 635-125-01-xxx 635-150-01-xxx 635-200-01-xxx 635-250-01-xxx 635-300-01-xxx 635-400-01-xxx RATIO 50:1A 60:1A 75:1A 100:1A 125:1A 150:1A 200:1A 250:1A 300:1A 400:1A ACCURACY @ 60HZ, pf = 0.95 ± % BURDEN (VA) 3.0 1.5 3.0 5.0 7.5 10 15 NOMINAL WINDING RESISTANCE (ohm) 0.05 0.06 0.15 0.31 0.38 0.57 0.95 1.20 1.45 0 * "xxx" describes termination: "T" FOR BRASS STUDS, "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)

CURRENT TRANSFORMER MODEL 2559 1.10" I.D. PAGE No 1-66 2.40 1.75 1.13 0 0 0.27 x 0.31 SLOT (4 PLACES) 8-32 BRASS STUD (2 PLACES) 1.10 2.70 0.16 1.25 NOTE: 1) ALL DIMENSIONS IN INCHES 2) ALL DIMENSIONS REF ONLY Specifications Secondary sources 5 amps AC at rated F.S. primary current Nominal operating frequency range is 50-400HZ Thermal rating factor is 1.33 @ 30C for all ratios Insulation voltage class is 0.6KV BIL 10KV For indoor applications only Reference documents IEEE C57.13, UL1244, CSA CAN3-C13-M83, and IEC 44-1 Enclosure is glass-filled nylon, color is black Options, contact Factory for information UL and Canadian UL Recognized Component. File E100575, 5.0, and 10 VAC output at F.S. primary amperage. Other non - standard ratings also available., 0.2, and 0.1 A output at F.S. primary amperage. Other nonstandard ratings also available Thermal ratings above 1.33 for selected ratios.

1.10" I.D. PAGE No 1-67 CURRENT TRANSFORMER MODEL 2559 TYPICAL EXCITATION CURVE for MODEL 2559 at 60HZ 10 1 10 0 INDUCED VOLTAGE (volt) 10-1 10-2 300:5A 400:5A 250:5A 150:5A 100:5A 200:5A 125:5A 75:5A 50:5A 60:5A 10-3 10-4 10-4 10-3 10-2 10-1 10 0 10 1 EXCITING CURRENT (amp) NUMBER * 2559-050-00-xxx 2559-060-00-xxx 2559-075-00-xxx 2559-100-00-xxx 2559-125-00-xxx 2559-150-00-xxx 2559-200-00-xxx 2559-250-00-xxx 2559-300-00-xxx 2559-400-00-xxx RATIO 50:5A 60:5A 75:5A 100:5A 125:5A 150:5A 200:5A 250:5A 300:5A 400:5A ACCURACY @ 60HZ, pf = 0.95 ± % BURDEN (VA) 3.0 2.5 4.0 5.0 7.5 10 15 NOMINAL WINDING RESISTANCE (ohm) 0.007 0.008 0.01 0.02 0.025 0.03 0.04 0.052 0.062 0.083 * "xxx" describes termination: "T" FOR BRASS STUDS, "Lyyy" FOR LEAD WIRES (Where "yyy" is the lead length in inches. For example, "L24" represents 24 inch long lead wires.)