Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230



Similar documents
BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

GAS EXTINGUISHING SYSTEMS INERT GAS EXTINGUISHING SYSTEMS. Argotec Liquid Argon Gas Extinguishing Technology (LAR)

CO 2. fire extinguishing systems

DATA CENTER FIRE PROTECTION

BRANCH SOLUTION. Automatic fire extinguishing systems for paint spraying plants. Safe for certain.

INERGEN - EXTINGUISHING SYSTEMS

COMITÉ EUROPÉEN DES ASSURANCES

Alarm and Detection/Suppression

How intelligent must an extinguishing solution be to keep fire virtual?

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

Maximum uptime and optimum fire safety for your data center

Maximum uptime and optimum fire safety for your data center

PLAN REVIEW GUIDE FOR FIRE ALARM

Risk Engineering Guideline

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

BS 7 SIS Safety Information System Green Light for Your Production

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

CBD-233. Fire Alarm and Detection Systems

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

Extract of the White paper Reduce energy costs in compressed air systems by up to 60%

How can I protect valuable assets from fire and ensure business continuity?

University of Houston Master Construction Specifications Insert Project Name

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY

fire detection CCTV access control alarms network cabling Camdetech Technologies (Pty) Ltd. Reg. No: 2000 / / 07 COMPANY PROFILE

Module 5. Fire and Emergency Alarm System Part I- Basics

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Fire suppression system for engine compartments USER MANUAL

Fire Safety Risk Assessment Checklist for Residential Care Premises

Data Center Infrastructure & Managed Services Outline

Fire protection in archives and storage vaults

OREGON FIRE CODE Interpretations and Technical Advisories

The ABB i-bus KNX Room Master Concept Your first step into the KNX world

ECHM Recommendations for Safety in multiplace medical hyperbaric chambers

Conventional Fire Detection and Extinguishant Control System Specification

2014 Limited Plan Submittal Checklist

IMO. 8 June 1998 *** I:\CIRC\MSC\848.WPD INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

ENGINEERING SPECIFICATIONS

Fire Protection of Data Centres

Building Services Engineering Technician

EXHIBIT A SCOPE OF WORK

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

Control and Indicating Equipment

Data Centre alwas protected always up and running.

City of Bettendorf Fire Alarm System Requirements

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

Important Ontario Fire Code Information for Building Owners in the City of Windsor

singapore//singapore data center specifications tel: fax: internet + intellectual property + intelligence

melbourne//australia data center specifications internet + intellectual property + intelligence tel: fax:

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Element D Services Plumbing

System off. Easy Series Intrusion Control Panel Making security easy now featuring wlsn* * wireless Local SecurityNetwork

SARATOGA FIRE DISTRICT EARLY WARNING FIRE ALARM SYSTEM STANDARDS AND REQUIRMENTS CONTENTS

- Save lives and reduce material damage

BS5839 Part 1:2002 Overview

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

THE GAS UTILITIES S AND THE JAPAN GAS ASSOCIATION S EFFORTS TO IMPROVE SAFETY

Inspection and Testing of Water-Based Systems

General Fire Code Requirements Within Commercial Tenant Spaces

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

E2-E3: ELECTRICAL CHAPTER-13 FIRE PROTECTION SYSTEM- EVOLVING TRENDS AND APPLICABILITY TO DATA CENTRE

12 Things Facility Managers Need to Know About Critical Power System Installation

Professional fire alarm panel for small and medium-sized objects. Compact

FIRE ALARM SYSTEM RECORD OF COMPLETION

FIRE-FIGHTING DESIGN BRIEF REPORT

FIRE ALARM SYSTEM RECORD OF COMPLETION

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Fire Protection Options for Data Centres

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Natural Gas Emergencies

Major Risks and Recommended Solutions

Guide to good leak testing

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

Potential problems with computer hard disks when fire extinguishing systems are released

Maintaining Fire Protection Systems

One united company. Advancing fire protection.

MOTOR FUEL DISPENSING SAFETY

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH CHEETAH Xi CONTROL PANEL

Hydrogen Leak Detection XRS system. The complete system for leak detection using hydrogen gas

KEMPER Leak Detection System

1.0 General. Inspection, Testing, and Maintenance 1 of 8

SECTION FIRE ALARM AND DETECTION SYSTEM

NATIONAL FIRE ALARM AND SIGNALING CODE

Automatic fire-extinguishing systems for commercial cooking

Ultrasonic Gas Leak Detection

GUIDELINES - Gas Inspection Regulations 1. Recommendations for camping site owners

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

FIRE EXTINGUISHER TRAINING

Basic Hydraulics and Pneumatics

Automatic Fire Fighting Monitors

ST FRS Services simplified FIREFIGHTING RESCUE SAFETY. Dräger. Technology for Life

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Inspect and Test FPAS Units of Competencies descriptions

High-efficient gas boiler CompactGas

Transcription:

Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec 1230 by 3M. This extinguishing agent is particularly suitable for the protection of spaces with electronic and electrical equipment and offers an economical fire protection solution especially for small and medium-sized rooms. The 50-bar technology of the MX 1230 system makes optimal use of the characteristics of this extinguishing agent. The Novec 1230 extinguishing agent reduces the heat of the fire and thus stops the combustion reaction. It is very efficient yet unaggressive at the same time. The extinguishing agent is stored as a liquid, it transforms into a gas only when it exits from the extinguishing nozzles. It therefore extinguishes, as a rule, even concealed fire sources instantaneously. The rapid extinguishing of a fire already in the nascent phase minimizes the fire damage and prevents long downtimes or business interruptions. Novec 1230 Molecule Furthermore, - unlike the case of water, foam or powder - secondary damage caused by the extinguishing agent itself is practically impossible. Therefore, Novec 1230 is neither corrosive nor electrically conductive, leaves no residue and can easily be removed from the space concerned through ventilation. Novec 1230 is, besides inert gases, the preferred extinguishing agent for electronic and electrical risks. Novec 1230 fire extinguishing systems already achieve their extinguishing effect at a substantially lower design concentration than that of inert gas extinguishing systems. This means that in the event of fire, less extinguishing agent must be introduced, which in turn makes it possible to implement shorter flooding periods. In addition, the pressure relief valve can be made significantly smaller, in most cases. Furthermore, the comparatively small quantity required for use is stored in liquid form. This allows for extremely compact storage of the extinguishing agent. In addition, in the design concentration of Novec 1230 does not present any health hazard, which is why MX 1230 installations are also suitable for areas with high human activity. Novec 1230 fluid has the best environmental properties, compared to other gaseous chemical extinguishing agents. It does not produce any hazard for the ozone layer and has a very low global warming effect. It dissipates completely within a mere five days.

50 bar...for more options MX 1230 systems are also available in addition to the operating pressures of conventional Novec 1230 fire extinguishing systems of 25 bar and 42 bar in a 50 bar configuration, which offers some significant advantages. For example, it can be adapted individually and tailored specifically to the requirements of the protected area. Longer pipelines The regulations for fire extinguishing systems using Novec 1230 require that the protected area be flooded within a maximum of 10 seconds. The 50-bar technology makes it possible to use longer and more complex piping than systems using lower operating pressures. This means that the extinguishing agent can also be stored outside the protected area. This option has the following advantages: In the event of fire, the extinguishing system itself is not exposed to fire. The space in the protected area can be used for its actual purpose, e.g. for additional server cabinets in the server room. The stock of extinguishing agent can be serviced quickly and easily without having to enter sensitive areas. Multi-zone systems With 50-bar technology, it is possible to set up one multi-zone system instead of several singlezone systems. Multi-zone systems jointly use a single stock of extinguishing agent for all rooms, while in the case of single-zone systems, a separate storage facility must be provided for each room. This reduces costs and saves space, especially if several rooms of a similar dimension have to be protected in a building. Conventional single-zone systems MX 1230 multi-zone technology Conventional extinguishing system with 25 bar MX 1230 fire extinguishing system with 50 bar

structure an Single-zone system MX 1230 fire extinguishing systems can be designed for use as a single-zone system to protect a single protected area or in the form of a multi-zone system to protect two or more areas. Single-zone systems A pipework system installed with MX 1230 extinguishing nozzles is installed in the protected space, while the dimension of the pipework, as along with the number and layout of the extinguishing nozzles, is determined by the risk concerned and the specific local conditions. The extinguishing agent is stored in liquid form in special cylinders, where a nitrogen cushion is superimposed over the extinguishing agent and thus generates the operating pressure of 42 or 50 bar. To protect smaller rooms, a single cylinder is often sufficient. Multi-cylinder systems are used to protect larger rooms. Smoke detectors continuously monitor the extinguishing zone and send a signal to the fire detection and extinguishing control panel in the event of a fire. In the case of single-cylinder systems, the control panel then opens the electrical valve of the extinguishing agent cylinder to release the agent into the pipework. In the case of multicylinder systems, the first cylinder is electrically activated and through the nitrogen cushion in this first cylinder, the other cylinders are triggered pneumatically. At the same time the fire detection and extinguishing control panel triggers an audible and visual alarm, whereby persons present will be asked to leave the room. At the same time, it transmits a signal to a permanently manned station. After expiry of a predetermined warning time, the extinguishing process starts: The extinguishing agent is carried through the pipework into the extinguishing zone within 10 seconds. nitrogen cushion Novec 1230 dip tube ➊ MX 1230 extinguishing agent cylinder ➋ Fire detection and extinguishing control panel ➌ Electric horn ➍ Flash ➎ Fire detector ➏ MX 1230 extinguishing nozzle ➐ Pressure relief flap

d function Multi-zone system Multi-zone systems Multi-zone systems are very similar to single-zone systems, except that they use a common stock of extinguishing agent to protect all rooms. In the event of a fire, the fire detection and extinguishing control panel controls specific selector valves. These valves release the extinguishing agent only into the extinguishing zones affected by the fire. The required quantity of extinguishing agent is always calculated in relation to the largest protected space. If a smaller space is affected by the fire, only as much extinguishing agent as is required is released to extinguish the fire in this space. Due to the reserve of extinguishing agent, the fire extinguishing capacity of the system is guaranteed even after the extinguishing system has been triggered - providing continuous, uninterrupted operation. Fire detection and extinguishing control panel: The control and function monitoring capacity of MX 1230 fire extinguishing systems should be provided ideally by the tried and tested Minimax FMZ 5000 fire alarm and extinguishing control technology. This ensures optimal compatibility - supported by relevant certifications - of electrical and mechanical system components and avoids unnecessary coordination expense and interface problems between different system parts. B C D A A B C D Extinguishing zone 1 Extinguishing zone 2 Extinguishing zone 3 Extinguishing zone 4 ➊ MX 1230 extinguishing agent cylinder ➋ Pneumatic control device ➌ Fire detection and extinguishing control panel ➍ Selector valve ➎ Electric horn ➏ Flash ➐ Fire detector ➑ MX 1230 extinguishing nozzle ➒ Pressure relief flap

ptimal Design with the Minimax DesignManager In the pipework, a two-phase flow - composed of liquid Novec 1230 and gaseous nitrogen - is generated after activation of the extinguishing system; this presents a particular challenge for the hydraulic calculation when planning the system. MX 1230 fire extinguishing systems are designed for specific projects with the Minimax Design Manager. This design program is based on a specially developed simulation model for the two-phase flow, which has been verified in numerous flow tests on extinguishing system models. Thanks to the calculation accuracy of the Minimax DesignManager, extinguishing systems can be optimally designed - both as regards safety systems and from an economic perspective: The designed extinguishing systems have been proven to be dependable and effective. Unlike conventional design programs, the Minimax DesignManager is also able to include zone distributors of multi-zone systems with up to 15 outlets in the calculation. It also calculates complex and asymmetric pipework, thus offering more flexibility in the system design. Whether a 50-bar, 42-bar or 25-bar system, single or multi-zone, symmetric or asymmetric pipework - Minimax DesignManager will always find the ideal system version and solution for each project. To further ensure safety in the design of the system, the guided menu of the Minimax DesignManager is designed so as to perform an error and plausibility check even while the basic data are entered into the system. Another highlight: An interface to the AutoCAD software integrated into the Minimax DesignManager offers a convenient design of the installation and makes it possible to import the result into the project documents and system records afterwards. Conventional extinguishing system with symmetric pipework MX 1230 fire extinguishing system with asymmetric pipework

APPLICATIONS A class on its own MX 1230 fire extinguishing systems are particularly suitable for the protection of spaces with electrical and electronic facilities, even if people are present in the premises. All system variants and options of the MX 1230 fire extinguishing systems, including the Minimax DesignManager, are tested and certified by FM Global, by UL as well as by VdS Schadenverhütung (independent German testing institution for fire protection and security). In addition, there are approvals by other international certification bodies. Examples of use Server rooms and other IT facilities Data archives Telecommunications equipment Control rooms and control stations Instrumentation and control rooms Electrical switch rooms Switchgear and distribution cabinets

enefits at a glance There are many reasons for choosing a MX 1230 fire extinguishing system by Minimax: The systems provide an excellent extinguishing effect in rooms with electronic and electrical equipment. MX 1230 50-bar technology - makes it possible to use long pipeworks The Novec 1230 extinguishing agent is neither corrosive nor electrically conductive, leaves no residue and can easily be removed from the space in question through ventilation. The Novec 1230 extinguishing agent is also very suitable for zones that are frequented by people and has a very high environmental compatibility. MX 1230 multi-zone technology - saves space and extinguishing agent Operating pressures up to 50 bar allow for more extensive pipework and storage of the extinguishing agent outside the protected area. Through cost-effective multi-zone systems, a single stock of extinguishing agent is sufficient to cover several zones. The Minimax DesignManager calculates complex, asymmetrical pipework automatically and delivers optimal solutions - both from a safety-related and an economic perspective. Minimax DesignManager - calculates the optimal solution Minimax GmbH & Co. KG Industriestrasse 10/12 D-23840 Bad Oldesloe Phone: +49 45 31 8 03-0 Fax: +49 45 31 8 03-248 E-Mail: clean-agents@minimax.de www.minimax.de PB14Ce_04/08.14/2/08.14/HA/21.231.010 Printed in Germany Photos Cover illustration: Minimax AG Page 7: Minimax AG/DLR/Fotolia For further information, see product sheets/product catalog Subject to technical modifications