Size: px
Start display at page:

Download "- Save lives and reduce material damage"

Transcription

1 - Save lives and reduce material damage

2 Small droplets reduce heat to a minimum Ultra Fog s high pressure water fog sprinkler system is based on water being sprayed through special nozzles at high pressure. The droplets created by these nozzles are extremely small. The area is filled with vapourised water and the fire will be extinguished rapidly. The small water fog droplets are converted into steam by the heat at an early stage of the fire. The amount of oxygen in the air is greatly reduced as a result of the increasing levels of steam. Furthermore, the water fog will create an over-pressure in the area, thus preventing fresh air from entering. In this way, the fire is suffocated and the water fog provides extremely effective cooling of both the area on fire and any surrounding objects. The smaller the droplets are, the earlier in the course of the fire the water fog is turned into steam, and the quicker the fire can be extinguished. Ultra Fog AB specialises in the design of high pressure water fog sprinkler systems for safer fire protection and fire fighting in on board and on shore facilities. Our headquarters are located in Gothenburg, Sweden, where all development, construction and manufacturing is carried out. Effective fire fighting is becoming more and more important in our world, to protect people as well as property. Water fog sprinkler systems are more effective than conventional sprinklers, and all kinds of fires are quickly extinguished. Ultra Fog AB provides customized solutions for water fog sprinkler systems to suit all needs. We are constantly developing our products to provide even better fire protection and higher quality for our customers. It is our opinion at Ultra Fog that good and safe fire protection requires both passive and active measures to be in sync. We also strongly believe in the importance of early triggering of the active fire protection system. It saves lives and reduces material damage. Ultra Fog provides its users with an advanced fire protection system with several different methods of fire detection and activation. The water fog sprinkler system can be customized for different environments and applications, and can be used to protect accommodation areas according to IMO Res A800(19) on boats and ships of all sizes. It can also be used to protect machinery areas up to 3,348 m 3 according to IMO MSC Circ In larger machinery areas, Ultra Fog can be used as local protection according to IMO MSC 913, since water fog is effective against fires in oils and other fluids, but is still entirely harmless. For example, it can be used for deep fat fryers. Ultra Fog AB has developed a system that fills sections of machinery areas, particularly the bilge, with foam in the event of fire. This system is used as a complement to the water fog system and is integrated with the rest of the Ultra Fog system. Ultra Fog s water fog sprinkler systems have been installed in many different types of boats and ships, for example yachts, passenger ferries, tankers and a replica 16th century ship.

3 Ultra Fog is a genuine water fog system, with all the advantages the technology provides. The sprinkler systems are designed to provide fire protection for passenger and guest accommodation areas, machinery areas and local protection of high risk areas. Ultra Fog systems for special applications are also used in areas outside the fire protection range. The Ultra Fog systems have proved to be successful, for example, in protecting in protecting vessels, offshore platforms, machinery areas and turbine enclosures. Ultra Fog is the solution of choice, particularly for applications where superior fire suppression performance, easy installation and minimal water damage are key benefits. Ultra Fog s technology provides safety for people, property and the environment in many diffrerent applications. It is backed-up by a dedicated team, whose aim it is to provide customer satisfaction. There are 3 different sprinkler system categories on the market: Ultra Fog has a range of working pressures, from 60 bar up to 150 bar, depending on what type of application the system is designed for. Normal working pressure is approx. 120 bar. This flexibility is possible due to the unique technology and design of the Ultra Fog nozzle. Ultra Fog systems are of the single fluid type, which means that only one set of pipework is necessary, which simplifies installation and maintenance. The water is easily supplied by pressurised cylinder arrangements, pumps or a combination of the two. Ultra Fog s Nozzle Range Ultra Fog offers a unique range of fog nozzles, designed for a wide variety of applications. The nozzle causes no loss in power; all energy is used to create the water fog. No moving parts are used in the nozzles, which contributes to high reliability of the system. All Ultra Fog nozzle types have been extensively tested by UL (Underwriters Laboratories) in the US. The patented Ultra Fog nozzle technology and design is unique on the market. 10 good reasons for choosing Ultra Fog 1. Major cooling effect when the water droplets transform into vapour. 2. Very high extinguishing effect - relative to the amount of water. Less damage to equipment and faster restoration. FACTS Ultra Fog Water Fog Sprinkler System: Droplet size: from 10 Microns up to 200 Microns. Working pressure: between bar. Low pressure system Conventional water sprinklers Working pressure below 12 bar. This type of system has at least 5 l/m 2 min of water consumption. Medium pressure system Mist waterspray The pressure range is from 12 bar up to 40 bar. Water consumption is at least 50-70% of conventional 3. Fast extinguishing - Fast sprinklers with low RTI value or by detectors. 4. Rarefied oxygen in the fire zone, through the water fog. 5. Over-pressure is produced in the space, which prevents new oxygen from joining the fire. 6. Flashover will be avoided by the water fog. Water consumption: 85 90% less compared to a conventional system. Pipe dimensions: from 8 mm to max. 50 mm. Extremely low weight: including water 90% less compared to a conventional water sprinkler system. water sprinkler systems. High pressure system Water fog The pressure range is from 40 bar up to 100/150/200 bar. The difference between mist and fog is the size of the droplets. Ultra Fog MicroX3 pump station, bar Total weight and amount of water reduced to a minimum Extremely high cooling effect 7. Reduced drain and scupper dimensions. The amount of dirty extinguished water will be kept to a minimum. 8. Environmentally friendly and safe - no toxins. Pump station, Pressurized Accumulators or a combination of both. More than 85% extinguishing effect will be reached when the droplets become steam. Fog has on average smaller droplets than mist. A high pressure water fog system has several advantages over the low and medium pressure systems, such as: The grade of heat expansion Size of drain and scupper systems reduced to a minimum Small pipe dimension 9. At sea, stability problems are reduced to a minimum. 10. Simple installation. Discreet piping system. Requires no hot work. 1,700 litres of water steam will be produced for each litre of water.

4 Conventional low pressure water spray or sprinkler systems can cause considerable water damage, which often is more extensive than the actual fire damage. Extinguishing fires with water fog is a superior method to most alternatives, through its efficiency and cleanliness. Ultra Fog AB has developed a number of different systems, for various different areas of application:: Ultra Fog for Accommodation Areas - IMO Res A800(19) Ultra Fog systems for accommodation areas can be activated in different ways, according to the Ultra Fog design of systems. When a nozzle is activated, the working pressure automatically increases to approx bar and the water fog is spread from the nozzle head(s). A signal is simultaneously sent to the control panel on the bridge. The water fog continues to be released until the pump(s) is/are turned off manually. Ultra Fog for Total Protection of Machinery Areas - IMO MSC/Circ. 1165, and Local Protection - IMO MSC/Circ. 913 For the protection of machinery and local risk areas, Ultra Fog s system is comprised of either pump(s) or cylinders, depending on the risk and the applicable regulations. Activation of the systems is manual and also by automatic release via the Local Protection System. Ultra Fog for Special Protection Ultra Fog has developed a number of different local protection systems. For example, deep fat fryers in accordance with ISO 15371, Gallery Duct protection, grill equipment, computer rooms, etc. Systems can be designed to operate with either a single nozzle or a group of nozzles. Open nozzles are normally used. Ultra Fog System Design Triggering can be set via a modern fire alarm system with a typical trigger time far below 60 seconds for normal fires. This is the ULTRA FOG INTEL- LIGENT SYSTEM, corresponding to IMO MSC circ Alternatively, the Ultra Fog system can be triggered by the quick response glass bulb, the ULTRA FOG CONVENTIONAL SYSTEM. The third alternative, when both these triggering methods are combined in a joint system concept, is the ULTRA FOG COMBINED SYSTEM. The aim of the fire extinction system is to save lives and property. Therefore it is extremely important that the system works smoothly. Our ambition is to deliver and install systems and service of the highest possible quality and best possible functionality. Service and maintenance With regular maintenance of the sprinkler system, you are ensuring full operational reliability in the event of a fire. The guarantee for operational reliability is Ultra Fog s qualified technicians and service staff that carry out the maintenance and service. This is to avoid faults remaining undiscovered until the day a fire breaks out, something that can lead to major losses. A service contract with Ultra Fog is the safest way to maintain the fog sprinkler system in its ultimate operative condition. Included in this contract are regular check-ups, and the service experts we employ are trained by us on our unique systems and components. The system operators carry out regular minor checks, such as ocular inspections and minor testing. Our certified service technicians take on more comprehensive service work and annual maintenance. Ultra Fog original quality The core of our fog sprinkler system is the unique components, individually and together. It takes a range of different components to create the perfect sprinkler system, and a system is no stronger than its smallest part. A pre-requisite for safe operation and high performance is that Ultra Fog s own original parts are used in the system. All components, such as nozzles, pumps, cylinders, electric contacts and manoeuvre panels are manufactured in our own workshop or by approved subcontractors. Ultra Fog s suppliers manufacture according to ISO We keep a comprehensive range of spare parts in stock to be able to provide the best possible service if something needs to be replaced quickly. When we install a system, we also offer an individual package with Ultra Fog original parts for your fog sprinkler system. That way, you always have direct access to important components for high operational reliability when you really need it! Ultra Fog s sprinkler system is your guarantee for high quality and reliable performance.

5 T R E & C O M P A N Y The Ultra Fog Water Fog System is rated as Class 1 according to the National Fire Protection Association Code (NFPA, USA). Basically, it means that Ultra Fog has the smallest average droplet size, which ensures effective fire fighting performance. Ultra Fog s Water Fog System has been fire tested by the Swedish Test Laboratory (SP) and Sintef, Norway, both of which are fully authorised by IMO. Ultra Fog has been tested and approved according to the IMO Res. A.800 (19), for accommodation areas, stores and service areas. IMO and MSC circ. 847 activation by detectors as an alternative to the glass bulb. IMO, MSC circ and MSC circ. 913, machinery areas and pump rooms. A Performance Effectiveness Analysis was carried out by DNV, Norway. Component by the laboratory of UL, USA. Our test procedures began in 1992 and are constantly being renewed in order to find new areas that need protecting by our exceptional water fog systems. We maintain close contact with our customers and we prefer to build long-term relationships. Partly to promote research and development within the specific areas, something which leads to better products. But also because it gives our customers a more precise service, as we can design and adapt our fire extinguishing system according to the different needs. Ultra Fog AB Backa strandgata 18 SE Hisings Backa Sweden Phone: +46-(0) Fax: +46-(0) sprinklersystem@ultrafog.se - Save lives and reduce material damage

- Save lives and reduce material damage

- Save lives and reduce material damage - Save lives and reduce material damage Ultra Fog specialises in high pressure sprinklers for fire extinction using water fog, both at sea and on land. Our base is in Gothenburg, which is where we carry

More information

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust Safer.Smarter.Tyco. Watermist fire protection Technology you can trust / 2 / / 3 / Trust in Tyco Tyco s AquaMist Systems Tyco Fire Protection Products helps to keep people, property and the environment

More information

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain

BRANCH SOLUTION. Fire protection for wind turbines. Safe for certain BRANCH SOLUTION Fire protection for wind turbines Safe for certain RISKING A FIRE IS RISKING YOUR INVESTM Over the last few years, the generation of electricity from wind energy has become a major technology

More information

Mission-critical fire protection HI-FOG for data centres

Mission-critical fire protection HI-FOG for data centres Mission-critical fire protection HI-FOG for data centres Modern fire protection for a data-driven world We make a strong case that HI-FOG is the best available fire protection for mission-critical data

More information

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009

Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 Full scale tunnel fire tests of VID Fire-Kill Low Pressure Water Mist Tunnel Fire Protection System in Runehamar test tunnel, spring 2009 By Carsten Palle, VID Fire-Fill, www.vid.eu Presented at ISTSS

More information

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

The Smarter Way of Fire Fighting Fire Fighting with Water Mist The Smarter Way of Fire Fighting Fire Fighting with Water Mist A Team of Specialists FOGTEC offers optimal service at all levels Locations and system partners FOGTEC systems use pure water, converting

More information

International Code for Fire Safety Systems (FSS Code) Resolution MSC.98(73)

International Code for Fire Safety Systems (FSS Code) Resolution MSC.98(73) International Code for Fire Safety Systems (FSS Code) Resolution MSC.98(73) INTERNATIONAL MARITIME ORGANIZATION London, 2001 Foreword The International Code for Fire Safety Systems (FSS Code) was adopted

More information

Risk Engineering Guideline

Risk Engineering Guideline www.hdi.global HDI Risk Consulting Risk Engineering Guideline Impairment of fire protection systems Basic protection systems should not be impaired without adequate replace compensation with provisions.

More information

Rotary vane steering gear for smaller vessels

Rotary vane steering gear for smaller vessels Steering gear Rotary vane steering gear for smaller vessels The SR series is designed with integrated frequency controlled pumps. General description Rolls-Royce supplies a complete range of steering gear,

More information

Fire Protection of Data Centres

Fire Protection of Data Centres Fire Protection of Data Centres With SEM-SAFE High-Pressure Water Mist System Danfoss Semco A/S Total Solution Provider of Certified Fixed Fire Fighting Systems Need a fire fighting system that: Allows

More information

Watermist fire suppression systems for commercial low hazard occupancies

Watermist fire suppression systems for commercial low hazard occupancies Watermist fire suppression systems for commercial low hazard occupancies Watermist fire protection systems are fire suppression systems that have emerged as an alternative fire safety solution for specific

More information

The Merchant Shipping (Fire Protection) Regulations 1998: Fixed fire detection alarm and extinguishing systems

The Merchant Shipping (Fire Protection) Regulations 1998: Fixed fire detection alarm and extinguishing systems MERCHANT SHIPPING NOTICE Maritime and Coastguard Agency MSN 1666 (M) The Merchant Shipping (Fire Protection) Regulations 1998: Fixed fire detection alarm and extinguishing systems Notice to Shipowners,

More information

Mission-critical fire protection HI-FOG for large data centres

Mission-critical fire protection HI-FOG for large data centres Mission-critical fire protection HI-FOG for large data centres Modern fire protection for a data-driven world The HI-FOG water mist fire protection system delivers efficient fire protection for your mission-critical

More information

IMO. 8 June 1998 *** I:\CIRC\MSC\848.WPD INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

IMO. 8 June 1998 *** I:\CIRC\MSC\848.WPD INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR E Telephone: 0171-735 7611 Fax: 0171-587 3210 Telex: 23588 IMOLDN G IMO Ref. T4/4.03 MSC/Circ.848 8 June 1998 REVISED GUIDELINES FOR

More information

Maximum uptime and optimum fire safety for your data center

Maximum uptime and optimum fire safety for your data center Maximum uptime and optimum fire safety for your data center Integrated and tailored fire safety solutions from one partner Answers for infrastructure. Complete solutions for a safe data center with a single

More information

The Smarter Way of Fire Fighting Fire Fighting with Water Mist

The Smarter Way of Fire Fighting Fire Fighting with Water Mist The Smarter Way of Fire Fighting Fire Fighting with Water Mist A Team of Specialists FOGTEC offers optimal service at all levels Locations and system partners Research & Development, Approvals FOGTEC Technology

More information

BOAT DECK MASKINCHEF OVERSTYRMAND BAD BAD VIDENSKABSLEDER CONFERENCE ROOM 1.STYRMAND OFFICE VENT MESS ELEV. MESS KONTOR C-14 LAB.

BOAT DECK MASKINCHEF OVERSTYRMAND BAD BAD VIDENSKABSLEDER CONFERENCE ROOM 1.STYRMAND OFFICE VENT MESS ELEV. MESS KONTOR C-14 LAB. RUM STYREMASKINERUM 5 HYDRAULIC SMEDJE MAIN ENGINE SAMPLES OP FORMALIN RUM FL 2 1 2 2 2 AUX. ENGINE ENGINE COMTROL CHANGE WORKSHOP COMPRESSOR HOSPITAL FINMEKANISK LOCKER LIN LAB. SPARE 1.MASKINMESTER LYTTERUM

More information

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations; (1979) (Rev.1 1990) (Rev.2 1996) (Rev.3 Jan 2012) Safety features.1 Fire protection and extinction.1.1 General Fire protection arrangements and fire extinguishing systems are to be in accordance with the

More information

REPUBLIC OF ALL SHIPOWNERS, OPERATORS, MASTERS AND OFFICERS OF MERCHANT SHIPS, AND RECOGNIZED ORGANIZATIONS

REPUBLIC OF ALL SHIPOWNERS, OPERATORS, MASTERS AND OFFICERS OF MERCHANT SHIPS, AND RECOGNIZED ORGANIZATIONS REPUBLIC OF Marine Notice THE MARSHALL ISLANDS No. 2-011-14 OFFICE OF THE MARITIME ADMINISTRATOR Rev. 2/12 TO: SUBJECT: ALL SHIPOWNERS, OPERATORS, MASTERS AND OFFICERS OF MERCHANT SHIPS, AND RECOGNIZED

More information

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY Office of Deputy Commissioner of Maritime Affairs THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY Marine Notice FIR-001 Rev. 06/12 TO: SUBJECT: ALL SHIPOWNERS, OPERATORS, MASTERS AND OFFICERS OF MERCHANT

More information

PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281

PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281 PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-281 PanCanal Building Albrook, Panama City Republic of Panama Tel: (507) 501-5355 jortega@segumar.com To: Ship-owners/Operators, Company Security

More information

ANNEX 3. RESOLUTION MSC.339(91) (adopted on 30 November 2012) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

ANNEX 3. RESOLUTION MSC.339(91) (adopted on 30 November 2012) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) Annex 3, page 1 ANNEX 3 RESOLUTION MSC.339(91) (adopted on 30 November 2012) ADOPTION OF AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) THE MARITIME SAFETY COMMITTEE, RECALLING

More information

GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING WATER FROM CLOSED VEHICLE AND RO-RO SPACES AND SPECIAL CATEGORY SPACES OF PASSENGER AND CARGO SHIPS

GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING WATER FROM CLOSED VEHICLE AND RO-RO SPACES AND SPECIAL CATEGORY SPACES OF PASSENGER AND CARGO SHIPS INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T4/4.01 MSC.1/Circ.1320 11 June 2009 GUIDELINES FOR THE DRAINAGE OF FIRE-FIGHTING

More information

For Data Center and Control Room Applications

For Data Center and Control Room Applications For Data Center and Control Room Applications Nearly zero wetting No costly clean up or equipment replacement Sustainable design Quick system recharge, minimal downtime No need for assurance of tight room

More information

Automatic fire-extinguishing systems for commercial cooking

Automatic fire-extinguishing systems for commercial cooking Automatic fire-extinguishing systems for commercial cooking Leading Items First Ignited in Eating and Drinking Establishment Structure Fires, 2000-2004 Annual Averages Cooking materials, incl. food and

More information

Technical Information

Technical Information Subject Maintenance, Testing and Inspection of Fire Protection Systems and Fire Fighting Systems and appliances on board the Singapore flag ships To whom it may concern Technical Information No. TEC-0977

More information

FIRE FIGHTING MANUAL AND REMOTE-CONTROLLED. Simple cabling just 2 power lines. Common Electronic Optimal reach

FIRE FIGHTING MANUAL AND REMOTE-CONTROLLED. Simple cabling just 2 power lines. Common Electronic Optimal reach FIRE FIGHTING MANUAL AND REMOTE-CONTROLLED Simple cabling just 2 power lines Common Electronic Optimal reach ZOOM I RANGE I ACCESSORIES I RESEARCH AFTER-SALES SERVICE - TRAINING MANUAL and REMOTE Petrojet

More information

Stena S-47. 47,200 DWT Product/Chemical Tanker CONQUEST CONQUEROR CONCORD CONCEPT CONSUL CONTEST

Stena S-47. 47,200 DWT Product/Chemical Tanker CONQUEST CONQUEROR CONCORD CONCEPT CONSUL CONTEST Stena S-47 47,200 DWT Product/Chemical Tanker CONQUEST CONQUEROR CONCORD CONCEPT CONSUL CONTEST The unique cargo handling system enables the S-47 to trade in multiple markets, bringing superior earnings

More information

Fire suppression in buildings using water mist, fog or similar systems

Fire suppression in buildings using water mist, fog or similar systems Fire suppression in buildings using water mist, fog or similar systems The authors of this report are employed by BRE. The work reported herein was carried out under a Contract placed by the ODPM. Any

More information

Maximum uptime and optimum fire safety for your data center

Maximum uptime and optimum fire safety for your data center Maximum uptime and optimum fire safety for your data center Integrated and tailored fire safety solutions from one partner Answers for infrastructure. Complete solutions for a safe data center with a single

More information

Rules for Classification and Construction Ship Technology

Rules for Classification and Construction Ship Technology I Rules for Classification and Construction Ship Technology 1 Seagoing Ships 19 Guidelines for the Carriage of Refrigerated Containers on Board Ships Edition 2003 The following Guidelines come into force

More information

Safety of Life at Sea, 1974 (SOLAS)

Safety of Life at Sea, 1974 (SOLAS) Safety of Life at Sea, 1974 (SOLAS) Prof. Manuel Ventura Ship Design I MSc in Marine Engineering and Naval Architecture Chapter II-2. Construction Fire Protection, Fire Detection and Fire Extinguishing

More information

Do you remove fumes from robotic welding and laser cutting?

Do you remove fumes from robotic welding and laser cutting? Do you remove fumes from robotic welding and laser cutting? Health and safety in the Automotive industry Do you offer a Safe and healthy Working environment? We do. To ensure a pleasant workplace for your

More information

Fire suppression system for engine compartments USER MANUAL

Fire suppression system for engine compartments USER MANUAL Fire suppression system for engine compartments USER MANUAL Contractor s machinery/vehicles, tooling machines and special machines Edition 2011-3 Hydro pneumatic activation Mechanical activation Electrical

More information

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES 1. Introduction TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES 1.1 This scheme details the tests and inspection of diesel engines manufactured by mass production system for use in marine

More information

MU 14879 0214. Cooling System. Hi-Pres. Low sulphur fuel cooling system. System specifications HI-PRES MARINE & OFFSHORE

MU 14879 0214. Cooling System. Hi-Pres. Low sulphur fuel cooling system. System specifications HI-PRES MARINE & OFFSHORE MU 14879 0214 Hi-Pres Cooling System Low sulphur fuel cooling system System specifications HI-PRES MARINE & OFFSHORE Hi-Pres MGO Cooling system Hi-Pres MGO Cooling System The Novenco Hi-Pres MGO cooling

More information

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System

Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System Amerex CPS FM-200 Waterless Pre-engineered Fire Suppression System A Simple Solution An Affordable Approach An Industry Innovation I N T R O D U C T I O N A SIMPLE SOLUTION. AN AFFORDABLE How many days

More information

Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines

Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines Content Introduction...5 Standard ambient matched engine...5 Operating at high seawater with standard matched engine...6 Non-standard

More information

ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS

ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS Journal of KONES Powertrain and Transport, Vol. 18, No. 011 ANALYSIS OF FIRE HAZARD AND SAFETY REQUIREMENTS OF A SEA VESSEL ENGINE ROOMS Adam Charchalis, Stefan Czy Gdynia Maritime University, Faculty

More information

How can I protect valuable assets from fire and ensure business continuity?

How can I protect valuable assets from fire and ensure business continuity? How can I protect valuable assets from fire and ensure business continuity? XC10 compact panels combine fire detection and extinguishing control for comprehensive safety. Answers for infrastructure. Compact

More information

Alfa Laval PureBallast 3.1

Alfa Laval PureBallast 3.1 Alfa Laval PureBallast 3.1 Ballast water treatment system 1000 m 3 /h system Alfa Laval PureBallast 3.1 is an automated inline treatment system for the biological disinfection of ballast water. Operating

More information

PRODUCT CATALOGUE OFFSHORE. RCONTAINER AS PHONE: 08188 E-MAIL: offshore@rcontainer.no ADDRESS: Industrivegen 11, 2166 Oppaker OFFSHORE 1

PRODUCT CATALOGUE OFFSHORE. RCONTAINER AS PHONE: 08188 E-MAIL: offshore@rcontainer.no ADDRESS: Industrivegen 11, 2166 Oppaker OFFSHORE 1 PRODUCT CATALOGUE OFFSHORE RCONTAINER AS PHONE: 08188 E-MAIL: offshore@rcontainer.no ADDRESS: Industrivegen 11, 2166 Oppaker OFFSHORE 1 2 OFFSHORE WHO WE ARE? Rcontainer is a Norwegian company founded

More information

PANAMA MARITIME AUTHORITY

PANAMA MARITIME AUTHORITY PANAMA MARITIME AUTHORITY MERCHANT MARINE CIRCULAR MMC-226 PanCanal Building Albrook, Panama City Republic of Panama Tel: (507) 501-5000 segumar@segumar.com To: Ship-owners/Operators, CSO, Legal Representatives

More information

IWMC 2015, Amsterdam, October 28-29, 2015 Practical experience from actual water mist installations. What can be learnt?

IWMC 2015, Amsterdam, October 28-29, 2015 Practical experience from actual water mist installations. What can be learnt? IWMC 2015, Amsterdam, October 28-29, 2015 Practical experience from actual water mist installations. What can be learnt? Magnus Arvidson Fire Research SP Technical Research Institute of Sweden magnus.arvidson@sp.se

More information

For Data Center and Control Room Applications

For Data Center and Control Room Applications For Data Center and Control Room Applications Nearly zero wetting No costly clean up or equipment replacement Sustainable design Quick system recharge, minimal downtime No need for assurance of tight room

More information

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar

ENGINEERING SPECIFICATION. Engineering Specification SAPPHIRE 42 Bar Engineering Specification SAPPHIRE 42 Bar PART 1 GENERAL 1.1 DESCRIPTION OF WORK This specification outlines the requirements for a "Total Flood" SAPPHIRE Clean Agent Fire Suppression System. The work

More information

NITROX // safer diving

NITROX // safer diving NITROX // safer diving Always available, easy to use and safe for daily use: NITROX diving gas offers professional divers, yacht owners and offshore facilities the highest level of convenience and independence

More information

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL January, 2003 Environmental Health and Safety Florida Atlantic University 777 Glades Rd. Boca Raton, FL 33431 Phone: 561-297-3129 Fax:

More information

M-20.2 SOLAS II-2. The latest IMO Briefing (IMO 29,2000) offered the following description of the 73rd Meeting of the Maritime Safety Committee:

M-20.2 SOLAS II-2. The latest IMO Briefing (IMO 29,2000) offered the following description of the 73rd Meeting of the Maritime Safety Committee: M-20.2 SOLAS II-2 THE PREFERRED EEBD SOLUTION The latest IMO Briefing (IMO 29,2000) offered the following description of the 73rd Meeting of the Maritime Safety Committee: The 73rd meeting of the IMO s

More information

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions The world s best selling supply unit. The right choice for any conditions AB-c arine Compact Heavy Fuel Oil supply unit This series of marine AB-c Heavy Fuel Oil () supply units is developed to combine

More information

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230

Technologies Gas extinguishing systems. MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 Technologies Gas extinguishing systems MX 1230 Fire Extinguishing Systems Fighting Fire using 3M Novec 1230 ire protection Efficient and compact MX 1230 fire extinguishing systems fight fires using Novec

More information

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL Siniša Stojan, Ph.D. student Damir Dražić, Ph.D. student Brodotrogir, HR - 21220 Trogir, Croatia sinisa.stojan@brodotrogir.hr,

More information

FIRE-FIGHTING DESIGN BRIEF REPORT

FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 1 SECTION 04 (Doc.No.A/DBR 001) FIRE-FIGHTING DESIGN BRIEF REPORT P a g e 2 1.0 SCOPE 2.0 STANDARDS AND CODES 3.0 TYPES OF SYSTEM PROPOSED 4.0 FIRE HYDRANT SYSTEM 5.0 AUTOMATIC SPRINKLER SYSTEM

More information

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection

Aerosol Fire Suppression. Your Choice for Special Hazard Fire Protection Aerosol Fire Suppression Your Choice for Special Hazard Fire Protection Traditional Special Hazard Fire Protection Centers Around Two Technologies Water deluge and chemical agent fixed systems protect

More information

EFSN Training i Module 1. 90 Minutes

EFSN Training i Module 1. 90 Minutes Introduction to Sprinklers EFSN Training i Module 1 90 Minutes Topics How sprinklers work Performance of sprinkler systems Types of Sprinkler Introduction to sprinkler systems Introduction ti to sprinkler

More information

FAIRBANKS NIJHUIS FIRE PROTECTION. www.fairbanksnijhuis.com FIRE PUMP SETS & PUMP PACKAGES

FAIRBANKS NIJHUIS FIRE PROTECTION. www.fairbanksnijhuis.com FIRE PUMP SETS & PUMP PACKAGES FAIRBANKS NIJHUIS FIRE PROTECTION FIRE PUMP SETS & PUMP PACKAGES www.fairbanksnijhuis.com KNOW-HOW AND EXPERIENCE WATER A fire can be extinguished by pumping water to its source. Therefore the most critical

More information

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 IMO E Ref. T5/1.01 MEPC.1/Circ.642 12 November 2008 2008 REVISED GUIDELINES FOR SYSTEMS

More information

ST-11662-2008. FRS Services simplified FIREFIGHTING RESCUE SAFETY. Dräger. Technology for Life

ST-11662-2008. FRS Services simplified FIREFIGHTING RESCUE SAFETY. Dräger. Technology for Life ST-11662-2008 FRS Services simplified FIREFIGHTING RESCUE SAFETY Dräger. Technology for Life 02 Total Care for your entire FRS equipment. STL-1198-2008 A unique combination of service and competence Ever

More information

LNG Storage and Fuel Gas Systems. LNG: Fuel for Shipping, London 15-Feb-2011. Carriers & Offshore Units. Jürgen Harperscheidt Sales Manager

LNG Storage and Fuel Gas Systems. LNG: Fuel for Shipping, London 15-Feb-2011. Carriers & Offshore Units. Jürgen Harperscheidt Sales Manager LNG Storage and Fuel Gas Systems LNG: Fuel for Shipping, London 15-Feb-2011 Carriers & Offshore Units Jürgen Harperscheidt Sales Manager CONTENT TGE Company Profile Small LNG carriers Bunkering LNG fuel

More information

IMO WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES

IMO WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES INTERNATIONAL MARITIME ORGANIZATION E IMO MARINE ENVIRONMENT PROTECTION COMMITTEE 51st session Agenda item 20 MEPC 51/INF.6 23 January 2004 ENGLISH ONLY WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES

More information

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13

presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Monday, 17 June, 13 presents Cooking With Fire Fixed Fire Suppression & Exhaust Systems for Cooking Environments Who is the AFSA? Safe and Secure Alberta Fire Safety Association Fire industry members working together to improve

More information

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION Phone System Owner Phone System Engineered by: of Record Drawings: of System Manuals: of Test Reports: System Installer 1. GENERAL INFORMATION Phone Delaware License No: Certificate Holder No. System Supplier

More information

MSC/Circ.1002 26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY

MSC/Circ.1002 26 June 2001 GUIDELINES ON ALTERNATIVE DESIGN AND ARRANGEMENTS FOR FIRE SAFETY INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: 020 7735 7611 Fax: 020 7587 3210 Telex: 23588 IMOLDN G IMO E Ref. MSC/Circ.1002 26 June 2001 GUIDELINES ON ALTERNATIVE

More information

Commercial Kitchen Fire Safety

Commercial Kitchen Fire Safety Commercial Kitchen Fire Safety Commercial grade kitchens are a common feature found in many churches today, as religious institutions are providing meals for daycares, soup kitchens, meals on wheels and

More information

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet

NMSU FIRE DEPARTMENT Commercial Kitchen Fire Suppression Worksheet This Commercial Kitchen Automatic Fire has been created to assure all documentation has been submitted to assist you in assuring proper plans and documentations has been submitted and reviewed by New Mexico

More information

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime

Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure Solutions Fast and efficient deployment, anywhere, anytime Containerized Infrastructure for Business-Critical Continuity Are you deploying a remote site faster than you can

More information

Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing

Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing Fire Protection Systems, Appliances and Compressed Gas Cylinders Periodic Maintenance, Inspection and Testing Notice to Shipowners, Ship Operators, Managers, Masters, Owners Representatives and Recognised

More information

Question: How effective is Tundra Fire Extinguishing Spray vs. a Traditional Fire Extinguisher?

Question: How effective is Tundra Fire Extinguishing Spray vs. a Traditional Fire Extinguisher? Introduction First Alert has launched Tundra Fire Extinguishing Spray, a Strong, Accurate, Fast and Effective new home-safety tool to extinguish fires. Tundra Fire Extinguishing Spray contains a powerful,

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE CERTIFICATE NO. P-14862 This is to certify that the Pipe System with Couplings with type designation(s) Megapress with SC-contour Issued to Viega GmbH & Co.

More information

Marine Generating Sets 3.7 to 50 kva

Marine Generating Sets 3.7 to 50 kva Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating

More information

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 viflow@viflow.fi www.viflow.fi

More information

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF Kompressoren Compressed Air Filters PF/DF/MF/SF/AF ALUP Filter For Compressed Air Purity Compressed air quality is related directly to the operating conditions of your compressor. Most compressor intake

More information

city of edmonds development information

city of edmonds development information #B17 city of edmonds development information Commercial Kitchen Hood & Hood Fire Suppression System Permit Submittal Requirements PERMIT REQUIRED: CODES: FEES: A Commercial Kitchen Hood Mechanical Permit

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description The TYCO RAPID

More information

Probabilistic Framework for Onboard Fire Safety

Probabilistic Framework for Onboard Fire Safety 1 Probabilistic Framework for Onboard Fire Safety Reliability and Effectiveness Models of Passive and Active Fire Safety Systems (D1.3) Philipp Lohrmann (BMT), Apurba Kar (IRS), Antoine Breuillard (BV)

More information

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008 HSE information sheet Fire and explosion hazards in offshore gas turbines Offshore Information Sheet No. 10/2008 Contents Introduction.. 2 Background of gas turbine incidents in the UK offshore sector...2

More information

Procedures for Approval of Service Suppliers

Procedures for Approval of Service Suppliers Working together for a safer world Procedures for Approval of Service Suppliers Reference: MARINE PASS version 2.2 01/15 Reporting date: February 2015 Report by: Statutory Support Group, Fleet Services,

More information

Alarm and Detection/Suppression

Alarm and Detection/Suppression Alarm and Detection/Suppression Fire Safety American Fire Technologies To provide special hazard services world wide to the industrial market through the integration of components and services Clean Agent

More information

Redefining Spray Technology

Redefining Spray Technology Redefining Spray Technology Macrospray Single-Point Nozzles Macrospray Spider Nozzles Macrospray nozzle technology Improved performance, lower cost Macrospray nozzle technology from Parker Hannifin s Gas

More information

Introduction. Procedure. Precautions. Records. Table of Contents. Contact. Disclaimer

Introduction. Procedure. Precautions. Records. Table of Contents. Contact. Disclaimer Fleet in Service, Technical Support (Dept. CL-D-FT) Checklist for Maintenance of Safety Equipment Hamburg, October 2013 0 Rev. 10/2013 Introduction This overview by Germanischer Lloyd provides requirements

More information

Blowdown vessels Meeting the requirements of HSE PM60

Blowdown vessels Meeting the requirements of HSE PM60 Blowdown vessels Meeting the requirements of HSE PM60 BDV60 blowdown vessels complete range of equipment for the safe disposal of boiler blowdown Boiler blowdown Steam boilers must be blown down to remove

More information

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group

OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group OBOA 2009 Huntsville, ON Overview of ULC Standards Affecting Building Occupancy Alan Cavers Area Manager Fire & Security Systems Group Course Title: Rev Date Agenda Introduction to Underwriters Laboratories

More information

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service)

FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) FIRE SPRINKLER SYSTEM SUPERVISORY SERVICE User s Guide (DamarNet RAR Service) The information provided in this user guide pertains to fire suppression sprinkler system monitoring service provided over

More information

Factory owners must ensure the boiler is:

Factory owners must ensure the boiler is: Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised

More information

MARINE FIRE SAFETY POCKET CHECKLIST

MARINE FIRE SAFETY POCKET CHECKLIST MARINE FIRE SAFETY POCKET CHECKLIST Reducing the risk of Port State Control detentions In conjunction with: The Lloyd s Register Group is an independent risk management organisation that works to improve

More information

ST. VINCENT AND THE GRENADINES

ST. VINCENT AND THE GRENADINES ST. VINCENT AND THE GRENADINES MARITIME ADMINISTRATION CIRCULAR N POL 008 - Rev 1 MARPOL ANNEX I OIL RESIDUE (SLUDGE) AMENDMENTS - MEPC 59 TO: SHIPOWNERS, SHIPS OPERATORS AND MANAGERS, MASTERS APPLICABLE

More information

STEEL VESSELS UNDER 90 METERS (295 FEET) IN LENGTH 2012

STEEL VESSELS UNDER 90 METERS (295 FEET) IN LENGTH 2012 RULES FOR BUILDING AND CLASSING STEEL VESSELS UNDER 90 METERS (295 FEET) IN LENGTH 2012 NOTICES AND GENERAL INFORMATION American Bureau of Shipping Incorporated by Act of Legislature of the State of New

More information

High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications

High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications International Water Mist Conference, London, United Kingdom,23-24 September, 2009 High Pressure Water Mist Systems: Alternative Solution For Critical Civil Applications Fire Fighting In Civil Applications

More information

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY

NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY NYC SUB-SYSTEMS INSTALLATION & SERVICE REQUIREMENTS OF THE FDNY Presented by: James Goerl Metro Protection Systems, Inc. jgoerl@metroprotectionsystems.com Agenda Introduction & Learning Objectives History

More information

Recovery of Persons from the Water

Recovery of Persons from the Water Recovery of Persons from the Water Guidelines for THE DEVELOPMENT OF PLANS AND PROCEDURES INTERNATIONAL CHAMBER OF SHIPPING (ICS) Representing the Global Shipping Industry Recovery of Persons from the

More information

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Ethanol Vehicle and Infrastructure Codes and Standards Citations Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and

More information

Total Solutions Providers for Fire & Security Systems

Total Solutions Providers for Fire & Security Systems Total Solutions Providers for Fire & Security Systems Tyco Fire & Security UAE is a joint venture between Suwaidi Engineering Group and Tyco Fire & Integrated Solutions. Established in 1994, we now employ

More information

MOBILE OFFSHORE DRILLING UNITS 2012

MOBILE OFFSHORE DRILLING UNITS 2012 Part 4: Machinery and Systems RULES FOR BUILDING AND CLASSING MOBILE OFFSHORE DRILLING UNITS 2012 PART 4 MACHINERY AND SYSTEMS American Bureau of Shipping Incorporated by Act of Legislature of the State

More information

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity? A Health and Safety Guideline for Your Workplace What is static electricity? What causes it? How is it hazardous? And, most importantly, how can it be controlled? All of these questions will be answered

More information

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT FIRE EXTINGUISHERS,SPRINKLER SYSTEMS AND FIRE ALARMS Attachment #1 Inspection of Fire Extinguishers Fire Extinguishers must be tested according

More information

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently

(68.52) X. June 2000 Supercedes February 2000. xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we look @ business differently (68.52) X June 2000 Supercedes February 2000 xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM.... we look @ business differently XENEX SYSTEM ARCHITECTURE Note: This schematic is for guidance only please

More information

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit

More information

Registered under: Instruction to RO s Nr. 10 Ban on the use of Asbestos on board ships

Registered under: Instruction to RO s Nr. 10 Ban on the use of Asbestos on board ships 1 INSTRUCTION TO SHIP OWNERS, SHIPPING COMPANIES AND RECOGNIZED ORGANIZATIONS (RO S) 1 Registered under: Instruction to RO s Nr. 10 Ban on the use of Asbestos on board ships (DATE ENTRY INTO FORCE: 01-12-2011)

More information

Fire Suppression Systems for Your Home

Fire Suppression Systems for Your Home ABN 64 127 735 433 PO Box 395 Mundaring. 6073. Phone/fax 9295 6263. Mob 0439 971 213 office@waterinstallations.com 18 Wandeara Cres, Mundaring. 6073. Fire Suppression Systems for Your Home Hills residents

More information