Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping module to the type range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available to include single pole with thermal-magnetic protection; double pole switching with thermal-magnetic protection on one pole, thermal protection on the other; double pole switching with thermal-magnetic protection on one pole only. All are offered with rocker switch or push button control - two buttons for ON/OFF or one button press-to-reset only, in designs to suit one of three different panel cut-out sizes. Illumination is optional. Approved to CBE standard EN 34 (IEC 34). Meets the requirements regarding fire resistance of EN 5- : 007-0 Safety of household and similar electrical appliances. Typical applications Motors, machine tools, office equipment, appliances. Standard current ratings and typical internal resistance values Internal resistance per pole (Ω) (A) thermal-magn. thermal 0. 65 4 0. 4.5 4 0.3 0. 0.4.7 5.40 0.5 7.7 4. 0.6 4. 3 0.8.65.50.4 0...5 0.7.5 0.74 0.45 0.4 0..5 0.0 0.0785 3 0.4 0.055 0.4 0.0565 4 0.0 0.04 5 0.06 0.0 6 0.043 0.05 7 0.0 0.05 8 0.0 0.0 0.0 0.0 < 0.0 < 0.0 4 < 0.0 < 0.0 5 < 0.0 < 0.0 6 < 0.0 < 0.0 Illumination voltage / Power consumption Operating voltage Power consumption Y + R G T V ma ma 4. ma 4 V ma ma 4. ma 48 V ma ma 4. ma 5 V 0. ma.8 ma. ma V 0. ma.8 ma. ma Technical data -...-M... For further details please see chapter: Technical Information Voltage rating AC 40 V (50/ Hz); DC 50 V 0...6 A Typical life -pole AC 40 V: 0...0 A,000 operations at x I N, inductive DC 50 V: 0...4 A,000 operations at x I N, inductive 4.5...6 A,000 operations at x I N, resistive DC 8 V: 4.5...0 A,000 operations at x I N, inductive -pole AC 40 V: 0...6 A 50,000 operations at x I N, inductive 7...0 A,000 operations at x I N, inductive DC 50 V: 0...6 A 50,000 operations at x I N, inductive 7...0 A,000 operations at x I N, inductive Ambient temperature -...+ C (-...+40 F) Insulation co-ordination rated impulse pollution (IEC 664 and 664 A) withstand voltage degree.5 kv reinforced insulation in operating area Dielectric strength (IEC 664 and 664A) test voltage operating area AC 3,000 V current path/current path AC,500 V Insulation resistance > 0 MΩ (DC 500 V) Interrupting capacity I cn 0... A 0 x I N.5...6 A 50 A -pole 50 A -pole Interrupting capacity (UL 77) I N U N 0...4 A AC 50 V 00 A 5... A AC 50 V,000 A...4 A AC 5 V,000 A Degree of protection operating area IP40 (IEC 5/DIN 40050) (with water splash protection IP54) terminal area IP00 Vibration 8 g (57-500 Hz) ± 0.6 mm (-57 Hz) to IEC 068--6, test Fc frequency cycles/axis Shock g ( ms) to IEC 068--7, test Ea Corrosion 6 hours at 5 % salt mist to IEC 068--, test Ka Humidity 40 hours at 5 % RH to IEC 068--78, test Cab Mass approx. 53 g (-pole) approx. 50 g (-pole) All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. Issue C www.e-t-a.com - 7
Thermal-Magnetic Circuit Breaker -...-M-.. Ordering information Type rocker switch/circuit breaker Mounting F snap-in frame Size of frame panel thickness 3 to fit in cut-out 50.5 x.5 mm - 6. mm (.03-.50 in) 5 to fit in cut-out 44.5 x mm - 4 mm (.03-.57 in) 6 to fit in cut-out 45 x.7 mm. -.4 mm (.047-.0 in) Number of poles -pole, thermal-magnetic protection -pole, thermal-magnetic protection on one pole, 5 -pole, thermal-magnetic protection on one pole, Mounting frame design collar height mm (.03 in) 3 collar height mm ( in) (with safety frame) 4 collar height mm (.07 in) with water splash protection (IP54) (not with -F6 frame) U with water splash protection and actuator guard Terminal configuration P7 blade terminals x.8-0.8 mm (QC x.) (terminals (k), (k),, ) H7 (k), (k): blade terminals x.8-0.8 (QC x.), : terminal screws M, blade terminals x.8-0.8 (QC x.) N7 as P7, but shunt terminals ((i) and (i)) are blade terminals x.8-0.8 (QC x.) G7 as H7, but shunt terminals ((i) and (i)) are blade terminals x.8-0.8 (QC x.) Characteristic curve M standard delay, therm..0-.4 x I N ; magn. 4- x I N AC Switch style W rocker Switch colour designation OPAQUE TRANSLUCENT (for illuminated versions) 0 black white 0 white 4 red 04 red 5 orange 6 sky blue green Rocker markings A 0 AUS OFF B I EIN ON C D 0 AUS OFF E F I EIN ON X A B C D E F X X = without marking Rocker illumination (optional).. Y white rocker, yellow LED.. T white rocker, blue LED. 4. R red rocker, red LED. 5. Y orange rocker, yellow LED. 6. T blue rocker, blue LED.. G green rocker, green LED Illumination voltage range (= operating voltage) - 4 V AC/DC 0-8 V AC/DC 3 0-40 V AC 4 85-75 V AC 5 4-54 V AC/DC 0...6 A - F 3 - N7 M - W A R 4 - A rdering example Ordering information Type push button switch/circuit breaker Mounting F snap-in frame Size of frame special frame for fitting splash cover 3 to fit in cut-out 50.5 x.5 mm panel thickness - 6. mm Number of poles -pole, thermal-magnetic protection -pole, thermal-magnetic protection on one pole, 5 -pole, thermal-magnetic protection on one pole, Mounting frame design F frame with two push buttons G frame with one push button Terminal configuration P7 blade terminals x.8-0.8 mm (QC x.) (terminals (k), (k),, ) H7 (k), (k): blade terminals x.8-0.8 (QC x.), : terminal screws M, blade terminals x.8-0.8 (QC x.) N7 as P7, but shunt terminals ((i) and (i)) are blade terminals x.8-0.8 (QC x.) G7 as H7, but shunt terminals ((i) and (i)) are blade terminals x.8-0.8 (QC x.) Characteristic curve M standard delay, therm..0-.4 x I N ; magn. 4- x I N AC Switch style/colour D push button (reset only) 0X black 04X red X white translucent X green translucent S push buttons ON/OFF GRX green translucent/red WRX white translucent/red WBX white translucent/black Push button illumination (optional) G green LED, AC/DC Y yellow LED, AC/DC R red LED, AC/DC Illumination voltage range (= operating voltage) - 4 V AC/DC 0-8 V AC/DC 3 0-40 V AC 4 85-75 V AC 5 4-54 V AC/DC 0...6 A - F 3 F - N7 M- S GRX G 4 - A ordering example Approvals Authority Voltage ratings VDE (EN 34) AC 40 V; DC 8 V 0...6 A DC 50 V 0...6 A double pole DC 50 V 0... A single pole CSA, UL AC 50 V 0... A AC 5 V 0...6 A CCC AC 50 V; DC 50 V 0...0 A The exact part number required can be built up from the table of choices shown above. Ordering references for optional features should be omitted if not required. - 8 www.e-t-a.com Issue C
Thermal-Magnetic Circuit Breaker -...-M-.. Dimensions Mounting frame variants Mounting style -F3., with rocker Collar height mm 7.76 5.84 6.6 OFF position optional illumination in ON position 54.3 Mounting style F3.3 with rocker collar height mm ( in.) 5.84.5.768 54.3.38 Installation drawing When installing the circuit breaker apply pressure on bezel only. operating area. 5.5.6.38. flat-head screw Mx5 ISO 580 tightening torque max. 0.8 Nm blade terminals DIN 4644-C-Ms-S (QC x.).38 5.5.6 8.87.70 4.55 4.6.8 flat-head screw Mx5 ISO 580 (H7 / G7) tightening torque max.0.8 Nm blade terminal DIN 4644-C-Ms-S (QC x.) 8.87.70 4.55 4.6 7.06.5.768 56..38 3.8.50.38. Required safety distances for rocker and push button.38 5.5.6 Mounting style F3.4 with rocker collar height mm (.07 in.), with water splash protection.8 mounting area 7 7 8.76.76. Cut-out dimensions 7.76 Mounting style F3.F- -S- with push buttons 5.5 5.84 6..638 optional illumination in ON position OFF position 54.3 4..55 Cut-out for mounting style -F3 with rocker and push button -6..03-.50.5 +0..846 +.008-0.4 -.06-0. -.008 max. R max.07 ±0.05 ±.00 50.5 +0.3. +.0 min..5 min.08 max. R0.3 max.0 Cut-out for mounting style -F6 with rocker panel thickness +0. - 0.05 +.008 -.00.7. - 0.4 -.06-0. -.008 max. R.5 max.05 ±0.05 ±.00 A min. min.07 max. R0.3 max.0 Mounting style F3.G- -D- with push button 5.84 6..638 optional illumination in ON position OFF position 54.3 4..55 Cut-out for mounting style -F5 with rocker -4 mm.03-.57 in. max. R0.3 max.0-0.4 -.06-0. -.008 max. R.5 max.05 ±0.05 ±.00 44.5 +0..75 +.008 min. min.07 +0.3.866 +.0 panel thickness dimension A +0.4 +0.8 + mm..6.4 +.06.047.063 +.03 +.03.04 +0, 45-0.05 45 +. +. mm - 0.05 45-0.05.77 +.008.77+.043 +.087 -.00 -.00.77-.00 Edges of working parts: ISO 375 5.5 For mounting styles -F.., -F5.., -F6.. please see section Thermal Overcurrent Circuit Breakers. Issue C www.e-t-a.com -
Thermal-Magnetic Circuit Breaker -...-M-.. Internal connection diagrams Accessories therm.-magn. protection on one pole line therm.-magn. protection on one pole line Insulated cover Y 3 068 0.5.08 (i) (k) I > (i) (k) (i) (k) I > (i) 0.787 0..0 Spacer for -F3... Y 3 675 0/0 Spacer for -F5... Y 3 676 0 Typical time/current characteristics at +3 C/+73.4 F 58.8 50.5. 5.05 44.5.75 Single or double pole load 0. A AC/DC ).866 8..03.5.886 8. 000 00 *.03 sharp-edged 0.8.03 Trip time in seconds 0 0. without bends * Y 3 675 0 suitable for panel thickness < mm (.07 in) * Y 3 675 0 suitable for panel thickness < 4 mm (.57 in) Blanking piece in -F3 size mounting frame Y 3 885 3.03 54.3 3. matt finish 5.84 6.5.650.5.08 0.0 0.00 4 6 8 0 40 80 0 times rated current. 36.4.5 6 A AC/DC ) 000 4.6.87 Trip time in seconds 00 0 0. Separate water splash cover, transparent (IP66) for use with -F5.. size mounting frames X 6 0 48.8 ø8. 5.84 0.0 0.00 4 6 8 0 40 80 0 times rated current 3.4.34 ø4.4.73 6.5.38.650 ) Magnetic tripping currents are increased by 5% on DC supplies. The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature F - -4 +4 +3 +73.4 +4 + +40 C - -0-0 +3 +40 +50 + Derating factor 0.8 0.76 0.84 0..08.6.4.36 73.87 - www.e-t-a.com Issue C
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping module to the type range described in catalogue section Thermal Overcurrent Circuit Breakers extends the choices available to include single pole with thermal-magnetic protection; double pole switching with thermal-magnetic protection on one pole, thermal protection on the other; double pole switching with thermal-magnetic protection on one pole only. All are offered with rocker switch actuation. Illumination is optional. Approved to CBE standard EN 34 (IEC 34). Meets the requirements regarding fire resistance of EN 5- : 007-0 Safety of household and similar electrical appliances. Typical applications Motors, machine tools, office equipment, appliances. Standard current ratings and typical internal resistance values Internal resistance per pole (Ω) (A) thermal-magn. thermal 0. 65 4 0. 4.5 4 0.3 0. 0.4.7 5.40 0.5 7.7 4. 0.6 4. 3 0.8.65.50.4 0...5 0.7.5 0.74 0.45 0.4 0..5 0.0 0.0785 3 0.4 0.055 0.4 0.0565 4 0.0 0.04 5 0.06 0.0 6 0.043 0.05 7 0.0 0.05 8 0.0 0.0 0.0 0.0 < 0.0 < 0.0 4 < 0.0 < 0.0 5 < 0.0 < 0.0 6 < 0.0 < 0.0 Illumination voltage / Power consumption Operating voltage Power consumption Y + R G T V ma ma 4. ma 4 V ma ma 4. ma 48 V ma ma 4. ma 5 V 0. ma.8 ma. ma V 0. ma.8 ma. ma Technical data -F7..-M.. For further details please see chapter: Technical Information Voltage rating AC 40 V, 50/ Hz; DC 50 V 0...6 A Typical life -pole AC 40 V: 0...0 A,000 operations at x I N, inductive DC 50 V: 0...4 A,000 operations at x I N, inductive 4.5...6 A,000 operations at x I N, resistive DC 8 V: 4.5...0 A,000 operations at x I N, inductive -pole AC 40 V: 0...6 A 50,000 operations at x I N, inductive 7...0 A,000 operations at x I N, inductive DC 50 V: 0...6 A 50,000 operations at x I N, inductive 7...0 A,000 operations at x I N, inductive Ambient temperature -...+ C (-...+40 F) Insulation co-ordination rated impulse pollution (IEC 664 and 664 A) withstand voltage degree.5 kv reinforced insulation in operating area Dielectric strength (IEC 664 and 664A) test voltage operating area AC 3,000 V current path/current path AC,500 V Insulation resistance > 0 MΩ (DC 500 V) Interrupting capacity I cn 0... A 0 x I N.5...6 A 50 A -pole 50 A -pole Interrupting capacity (UL 77) I N U N 0...4 A AC 50 V 00 A 5... A AC 50 V,000 A...4 A AC 5 V,000 A Degree of protection operating area IP40 (IEC 5/DIN 40050) (with water splash protection IP54) terminal area IP00 Vibration 8 g (57-500 Hz) ± 0.6 mm (-57 Hz) to IEC 068--6, test Fc frequency cycles/axis Shock g ( ms) to IEC 068--7, test Ea Corrosion 6 hours at 5 % salt mist to IEC 068--, test Ka Humidity 40 hours at 5 % RH to IEC 068--78, test Cab Mass approx. 53 g (-pole) approx. 50 g (-pole) Issue C www.e-t-a.com - 3
Thermal-Magnetic Circuit Breaker -...-M-.. Ordering information Dimensions Type rocker switch/circuit breaker Mounting F snap-in frame Size of frame panel thickness 7 to fit in cut-out 44.5 x mm - 4 mm (.03-.57 in) Number of poles -pole, thermal-magnetic protection -pole, thermal-magnetic protection on one pole, 5 -pole, thermal-magnetic protection on one pole, Mounting frame design N new design, grey P snap-on actuator guard grey Q snap-on splash cover grey R new design, black S snap-on actuator guard black T snap-on splash cover black Terminal configuration P7 blade terminals x.8-0.8 mm (QC x.) (terminals (k), (k),, ) H7 (k), (k): blade terminals x.8-0.8 (QC x.), : terminal screws M, blade terminals x.8-0.8 (QC x.) N7 as P7, but shunt terminals ((i) and (i)) are blade terminals x.8-0.8 (QC x.) G7 as H7, but shunt terminals ((i) and (i)) are blade terminals x.8-0.8 (QC x.) Characteristic curve M standard delay, therm..0-.4 x I N ; magn. 4- x I N AC Betätigungselement A Switch style Switch colour designation OPAQUE TRANSLUCENT (for illuminated versions) 0 black white 0 white 4 red 04 red 5 orange 0 green greeen 0 blue blue 6 sky blue 36 sky blue Rocker markings I 0 Mounting style -F7.N and -F7.R 8...0 8..0. 5.84 5.5.6 34.34 8.8.740 5.5.6.38.87 blade terminals DIN 4644-C-Ms-S (QC x.) flat head screw ISO580 Mx5-MS tightening torque max. 0.8 Nm Mounting style -F7.P and -F7.S.38.87 blade terminals DIN 4644-C-Ms-S (QC x.) flat head screw ISO580 Mx5-MS tightening torque max. 0.8 Nm LINE (i) (k) 5.5.6 LINE (i) (k) 5.5.6 48 ±0..8±.008 44. -0..74 -.008 8.70 4.6.36 44. -0,.74-.008 8.70 4.6 3 4.55 4.55.8.8 5..3.8 Q Q I and 0 moulded in Push button illumination (optional) Q T white wocker, blue LED 4 Q R red rocker, red LED 5 Q Y orange rocker, yellow LED Q G green rocker, green LED Q G blue rocker, green LED 36 Q T sky blue rocker, blue LED Illumination voltage range (= operating voltage) - 4 V 0-8 V 3 0-40 V 4 85-75 V 5 4-54 V AC/DC 0...6 A - F 7 N - N7 M- A Q T 4 - A ordering example Mounting style -F7.Q and -F7.T. 34.34 8.6.73.38.87 blade terminals DIN 4644-C-Ms-S (QC x.) flat head screw ISO580 Mx5-MS tightening torque max. 0.8 Nm 5.5.6.36 44.8.76 LINE (i) (k) 8.70 4.6 4.55.5.453.8-3 www.e-t-a.com Issue C
Thermal-Magnetic Circuit Breaker -...-M-.. Installation drawing Internal connection diagrams When installing the circuit breaker apply pressure on bezel only. operating area therm.-magn. protection on one pole line therm.-magn. protection on one pole line LINE (i) (k) 5.5.6 I > (i) (k) (i) (k) I > (i) (k) (i) 7.76 7.76 Cut-out dimensions mounting area 8 7..76 Typical time/current characteristics at +3 C/+73.4 F Single or double pole load 0. A AC/DC ) 000 00-4.03 -.57-0,4 -.06-0, -.008 max. R.5 ±0,05 ±.00 max.05 min. min.07 Trip time in seconds 0 +0.3.866 +.0 44.5 +0.4 max. R0.3.75 +.06 max.0 0. 0.0 Edges of working parts: ISO 375 0.00 4 6 8 0 40 80 0 times rated current Approvals.5 6 A AC/DC ) 000 Authority Voltage ratings VDE (EN 34) AC 40 V; DC 8 V 0...6 A DC 50 V 0...6 A double pole DC 50 V 0... A single pole CSA, UL AC 50 V 0... A AC 5 V 0...6 A CCC AC 50 V; DC 50 V 0...0 A Trip time in seconds 00 0 0. 0.0 0.00 4 6 8 0 40 80 0 times rated current ) Magnetic tripping currents are increased by 5% on DC supplies. The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature F - -4 +4 +3 +73.4 +4 + +40 C - -0-0 +3 +40 +50 + Derating factor 0.8 0.76 0.84 0..08.6.4 Issue C www.e-t-a.com -
Thermal-Magnetic Circuit Breaker -...-M-.. Accessories Insulated cover Y 3 068 0.5.08 0.787 0..0 5.05 44.5.75.03 Translucent water splash cover (IP54) X 43 0 Consisting of - Y 7 07 0 snap-on frame with actuator guard - Y 7 06 0 soft plastic cover Snap-on frame with actuator guard (can be snapped on as switch-on protection or switch-off protection) Y 7 07 0 8.8 5..740.3.36 Spacer for -F7... Y 3 676 0.03.5.886 8. sharp-edged without bends 0.8.03.5.08 8.8.5.740.453.36 34..34.38 34..34.38 All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.product markings may not be exactly as the ordering codes. Errors and omissions excepted. - 34 www.e-t-a.com Issue C