ALTAIR 5 with WirelessUSB module ALTAIR 5X with WirelessUSB module



Similar documents
SAFETY MANUAL. Ultima OPIR-5 Infrared Open Path Gas Detector

ALTAIR Family Gas Detectors A Tough Bunch

Operating Manual ALTAIR 4X. Multigas Detector. Order No /02

Escape Device Range. For a Safe Escape

ALTAIR 4 Four Gas Multigas Detector

it500 Internet Thermostat INSTALLER MANUAL

Lockout Specification BW Clip Maintenance-free single gas detector

A free call from your Roadpost satellite phone: A free call from North America:

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

BW TECHNOLOGIES GasAlertMicroClip Soft Tools Instruction Sheet

Genuine BMW Accessories. The Ultimate Driving Machine. BMW Trackstar. tracked. recovered. BMW TRACKSTAR.

Welcome to a whole new level of interactive home security

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

GSM WIRELESS DIGITAL ALARM SYSTEM USER GUIDE. Please read it carefully before installation and operation

Fleet Manager II. Operator Manual

Mondelēz International entity which issued the PO matches Mondelēz International entity to which you issue your invoice

How to connect your D200 using Bluetooth. How to connect your D200 using GPRS (SIM Card)

PR-2500 Portable Receiver. Owner s Manual

SECON-X. Technical Documentation. SECON-Vap user manual. Version: 1 Edition: Article no.:

GX-2009 Data Logger Management Program Operator s Manual

Operating Manual ALTAIR 5X PID. Multigas Detector. Order No.: /00. MSAsafety.com

Table of Contents. Use. Troubleshooting. Setup. Welcome. 11 How to arm/disarm system/camera(s) 19 Sync Module setup issues. 3 Installing the Blink app

Automated Test System SIMPLICITY COUNTS MSA s New GALAXY GX2 Automated Test System / Advanced Safety Management Effortless Operation

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Advanced Software Upgrade Guide

TP TP8-28 GSM. User quick guide Release: FW version: Control panel versions: Programming SW version: Update: Language:

Fleet Logistics partners with AlertDriving to offer online driver training and risk assessment

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Release Notes: PowerChute plus for Windows 95 and Windows 98

mysensors mysensors Wireless Sensors and Ethernet Gateway Quick Start Guide Information to Users Inside the Box mysensors Ethernet Gateway Quick Start

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Wireless Laser Barcode Scanner ils 6300BU. User s Manual

Installation & Operations Manual

Jabra LINK 220 Jabra LINK 220a

How to get your invoice paid on time?

RECON-4 Portable Multi-gas Detector Software Manual

Reference Manual. IQ System Database Manager Software

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

mysensors mysensors Wireless Sensors and and Cellular Gateway Quick Start Guide Information to Users Inside the Box

ALTAIR 5X Multigas Detector Bid Specification

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

24 Hour Secure Operating Centre * Customer Services * (Monday-Friday 8.30am-5.30pm)

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Impact Uni-Vent 750 Portable Ventilator

Quantum View Manage Administration Guide

BadgeRAE. User Manual. PGM-1010 CO Detector PGM-1020 H 2. S Detector

Standard Operating Procedure

ThinkServer PC DDR3 1333MHz UDIMM and RDIMM PC DDR3 1066MHz RDIMM options for the next generation of ThinkServer systems TS200 and RS210

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

Monnit Wi-Fi Sensors. Quick Start Guide

Theatres/Channels All theatres. Indirect channel. Author/Owner

Desktop Programmer (DTP)

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

Guide. Axis Webinar User Guide

evohome Wireless Radiator Zoning Kit Installation & User Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

RouteFinder SOHO. Quick Start Guide. SOHO Security Appliance. EDGE Models RF825-E, RF825-E-AP CDMA Models RF825-C-Nx, RF825-C-Nx-AP

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

BECAUSE WEATHER MATTERS UBIMET

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

Weather Direct Displays show Lost Forecast (blank boxes in the picture icons)

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

How to Configure your Energate Foundation Wi-Fi USNAP Radio Module.

Impact Uni-Vent 754 Portable Ventilator

Stolen Vehicle Tracking and Monitoring Services

EM6556 e-domotica Mini Switch

e-ask electronic Access Security Keyless-entry

Hot Spot (Unsecured) Wireless Access Initial Setup and Login for MCC_HOTSPOT

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

HDCVI Series DVR Quick Start Guide

Operating instructions TSE Wireless Software Home

Quantum View SM Manage Administration Guide

User Manual Software for DSL Digital Speed Switch

Disclaimers. Important Notice

BlackVue Cloud App Overview...3. Getting Started...6. Basic Menu Screens BlackVue Cloud BlackVue Wi-Fi Internal Memory...

FA701 Series. User s Guide. K6249-2V2 5/09 Rev. A

OxySense Gen III Operations Manual

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Sierra Wireless AirCard Watcher Help for Mac OS X

RGC-IR Remote Gas Calibrator for IR400

User manual. Your best protection against theft and loss. (Android) Made for

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

GC2 Panel User Guide

Stolen Vehicle Tracking and Monitoring Services

Step by Step Guide for Upgrading Your NetCamPro Camera to Cloud Mode Using an Android Device

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

SDHC Memory Card With Embedded Wireless LAN Functionality FlashAir W-02 Supplementary Manual. SDHC Memory Card

How To Use An Irius Pid Detector

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

External Hard Drive esata & USB 2.0 Combo. User Guide English

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Panel Controller MPC-xxxx-B FPA-1200-MPC. Operation guide

LYNX Touch L7000 Series Security System

Group of Administrative Co-operation Under the R&TTE Directive. 5 th R&TTE Market Surveillance Campaign on WLAN 5 GHz

A Class Air Source Heat Pump User Guide

XFINITY HOME SECURITY

Transcription:

Operating Manual ALTAIR 5 with WirelessUSB module ALTAIR 5X with WirelessUSB module Supplementary Information Order No. 10102623/01

MSA AUER GmbH Thiemannstrasse 1 D-12059 Berlin Germany MSA AUER GmbH. All rights reserved

MSA Contents Contents 1 Safety Regulations... 4 1.1 Correct Use... 4 1.2 Liability Information... 4 2 Description... 5 3 Operation... 6 3.1 Measurement Mode [Normal Operation]...6 3.2 Activation... 7 3.3 Startup... 8 4 Pairing... 9 4.1 alphascout... 9 4.2 alphahud alarm status... 9 4.3 TecBOS.solutions... 10 5 Appendix... 13 5.1 Menu Sequence from Main Page... 13 5.2 Menu Sequence Startup... 14 5.3 Menu Sequence Login Procedure... 15 5.4 Sequence of lost WirelessUSB Connection... 16 GB ALTAIR 5 WirelessUSB 3

Safety Regulations MSA 1 Safety Regulations 1.1 Correct Use TheALTAIR 5/ALTAIR 5X WirelessUSB module is used for communication with other devices, e.g. alphascout. The ALTAIR 5/ALTAIR 5X Multigas Detector is intended for use by trained and qualified personnel. It is designed to be used when performing a hazard assessment to: - Assess potential worker exposure to combustible and toxic gases and vapours as well as low level of oxygen. - Determine the appropriate gas and vapour monitoring needed for a workplace. It is imperative that this operating manual be read and observed when using the product. In particular, the safety instructions, as well as the information for the use and operation of the product, must be carefully read and observed. Furthermore, the national regulations applicable in the user's country must be taken into account for a safe use. Alternative use, or use outside this specification will be considered as non-compliance. This also applies especially to unauthorised alterations to the product and to commissioning work that has not been carried out by MSA or authorised persons. 1.2 Liability Information Danger! This product is supporting life and health. Inappropriate use, maintenance or servicing may affect the function of the device and thereby seriously compromise the user's life. Before use the product operability must be verified. The product must not be used if the function test is unsuccessful, it is damaged, a competent servicing/maintenance has not been made, genuine MSA spare parts have not been used. MSA accepts no liability in cases where the product has been used inappropriately or not as intended. The selection and use of the product are the exclusive responsibility of the individual operator. Product liability claims, warranties also as guarantees made by MSA with respect to the product are voided, if it is not used, serviced or maintained in accordance with the instructions in this manual. 4 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Description 2 Description ALTAIR 5 This manual only contains information regarding the WirelessUSB module. Refer to the Operating Manuals of ALTAIR 5/ALTAIR 5X for information on all other functions of the device. 1 5 2 3 4 6 Fig. 1 Instrument view 1 ALTAIR 5 WirelessUSB 4 Button 2 Button 5 Belt Clip 3 ON/OFF Button 6 WirelessUSB module GB ALTAIR 5/ALTAIR 5X WirelessUSB 5

Description MSA ALTAIR 5X 1 5 2 3 4 6 Fig. 2 Instrument view 1 ALTAIR 5X WirelessUSB 4 Button 2 Button 5 Belt Clip 3 ON/OFF Button 6 WirelessUSB module 6 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Operation 3 Operation 3.1 Measurement Mode [Normal Operation] The following options pages can be executed from the Normal Operation screen: BUMP page [ALTAIR 5X only] Peak Page* Min Page STEL Page* TWA Page Date Page Last Cal Date Cal Due* Motion Alert Wireless This page allows user to perform a Bump Test on installed sensors This page shows the peak readings for all sensors. This page shows the minimum readings for the oxygen sensor. This page shows the calculated STEL readings of the instrument. This page shows the calculated TWA readings of the instrument. This page shows actual date settings of the instrument. This page shows the date of the last calibration. This page shows the set date for the next calibration. This page allows the Motion Alert Feature to be activated or deactivated. This page allows the Wireless communication to be activated or deactivated. * The display of these pages can be de-activated through MSA Link software Using the three instrument buttons, the user can navigate through each sub-menu in a top/down sequence. Refer to the Operating Manual of ALTAIR 5/ALTAIR 5X and additional information in chapter 5 [appendix] for detailed instructions on navigating through these screens. GB ALTAIR 5/ALTAIR 5X WirelessUSB 7

Operation MSA 3.2 Activation Fig. 3 Switch Wireless ON / OFF (1) To activate the WirelessUSB module, follow the menu sequence described in chapter 5. The WirelessUSB module can be switched ON or OFF. (2) Switch the WirelessUSB module ON. The following options are shown below the antenna symbol: Retry New Abort Try again to connect to the last partner, e.g. partner is activated to pair Connect to a new partner Cancel operation and return to main menu The symbol will have different colours for different connection states: Status Indication Symbol WirelessUSB module available No connection strength bars visible [otherwise no symbol with strength bars on display] black strength bars Pairing mode [ready for pairing] Connection established and data exchange working Connection lost blinking black strength bars green strength bars blinking red strength bars 8 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Operation 3.3 Startup The product recognises an attached WirelessUSB module automatically. During the power-up sequence, the product will pair automatically with the last connected product. To pair two products, the pairing mode must be activated for all products. Otherwise no partner can be found. Fig. 4 Display with antenna symbol The strength bars in the status bar of the colour display are used for displaying the availability of a WirelessUSB module. During the startup sequence the product tries to pair with the last partner. The strength bars are blinking. After the Fresh Air Setup [FAS] the antenna symbol will be displayed. GB ALTAIR 5/ALTAIR 5X WirelessUSB 9

Pairing MSA 4 Pairing For further information see Operating Manual of the respective products. 4.1 alphascout Pairing with the alphascout (1) Make sure that the alphascout is already switched ON. If the alphascout is switched OFF the alphascout will start pairing with an alphamitter and not with an ALTAIR 5 WirelessUSB. (2) Push the green button on the alphascout for approx. 3 seconds. The alphascout is ready for pairing with an ALTAIR 5 WirelessUSB. On the display the message "DATA" blinks. A short signal sounds. The "bar" symbol is shown when the communication between alphascout and alphamitter is established. The "bar" symbol is not affected by pairing devices [such as alphahud and ALTAIR 5 WirelessUSB]. When the pairing of the ALTAIR 5 WirelessUSB module and the alphascout was successful the "DATA" symbol stops blinking and remains static. The unit is now paired with this product. If this combination is to be kept, during the next operation only the valve on the compressed air cylinder has to be opened. When replacing the products, the pairing procedure must be carried out again in order to clearly allocate the units to each other. 4.2 alphahud Alarm Status Status / Alarm Gas alert 1 Gas alert 2 Visual LED display representation Radio status LED flashing orange: - all gas alarms [low/high], sensor failure, pump blocked Radio status LED flashing yellow: - battery warning 10 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Pairing 4.3 TecBOS.solutions The user interface of the monitoring software is self-explanatory. The user interface is subdivided into three main areas: - Log in area for users with alphascout, - Team overview, - Detailed display of pressure, remaining service time and alarm, and the menu bar [ Fig. 5]. 1 4 3 Fig. 5 User interface telemetry monitoring software 1 Menu bar 2 Team overview 3 Log in area for users with alphascout 4 Detailed display [pressure, remaining service time, alarm] 2 GB ALTAIR 5/ALTAIR 5X WirelessUSB 11

Pairing MSA Integration into the Monitoring & Alarm System The software only displays the data of the WirelessUSB. There is no interaction between software and WirelessUSB module. The WirelessUSB module enables the integration of ALTAIR 5/ALTAIR 5X into the alpha Personal Network. You can monitor people using breathing apparatus and portable gas detection equipment while sending information to a central control station. If a WirelessUSB module is connected to an alphascout, an icon of the WirelessUSB module is shown near to the helmet [ Fig. 5]. normal: Data display in detail error: gas alert: connection lost: 12 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Pairing Default Settings for ALTAIR 5/ALTAIR 5X WirelessUSB Fig. 6 Default settings GB ALTAIR 5/ALTAIR 5X WirelessUSB 13

Appendix MSA 5 Appendix 5.1 Menu Sequence from Main Page Coming from Date Page Last Cal Date Main Page Cal Date Main Page Motion Alert Toggle Motion Alert On/Off Wireless Main Page Fig. 7 Turn wireless ON/OFF Toggle Wireless On/Off 14 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Appendix 5.2 Menu Sequence Startup Turn on ALTAIR 5/5X WUSB module attached no yes WUSB features activated Was already conn. to master no Message: FIND WIRELESS DEVICE? Yes No yes Search last master [start login] yes User decision no Found last master no yes Message: WIRELESS FOUND CONNECTED TO... Message: WIRELESS NOT FOUND Retry New Abort Start WUSB data mode retry User decision abort Normal operation new Start login to new master Fig. 8 Startup ALTAIR 5/ALTAIR 5X WirelessUSB GB ALTAIR 5/ALTAIR 5X WirelessUSB 15

Appendix MSA 5.3 Menu Sequence Pairing Procedure Start login to new master retry Connect successful no Message: WIRELESS NOT FOUND Retry Abort User decision yes abort Message: WIRELESS FOUND CONNECTED TO... WUSB menu item Measurement mode Fig. 9 WirelessUSB pairing procedure 16 ALTAIR 5/ALTAIR 5X WirelessUSB GB

MSA Appendix 5.4 Sequence of lost WirelessUSB Connection Data exchange failed Message: WIRELESS LOST Signal bars blinking red User interaction: Disable WirelessUSB or start new pairing process Automatic search for last master no Master found? yes Normal Operation Fig. 10 Handling of lost WirelessUSB connection GB ALTAIR 5/ALTAIR 5X WirelessUSB 17

MSA in Europe [ www.msa-europe.com & www.msa-gasdetection.com ] Northern Europe Southern Europe Eastern Europe Central Europe Netherlands MSA Nederland Kernweg 20 1627 LH Hoorn Phone +31 [229] 25 03 03 Fax +31 [229] 21 13 40 info@msaned.nl France MSA GALLET Zone Industrielle Sud 01400 Châtillon sur Chalaronne Phone +33 [474] 55 01 55 Fax +33 [474] 55 47 99 message@msa-gallet.fr Poland MSA Safety Poland ul. Wschodnia 5A 05-090 Raszyn k/warszawy Phone +48 [22] 711 50 33 Fax +48 [22] 711 50 19 eer@msa-europe.com Germany MSA AUER Thiemannstrasse 1 12059 Berlin Phone +49 [30] 68 86 0 Fax +49 [30] 68 86 15 17 info@auer.de Belgium MSA Belgium Duwijckstraat 17 2500 Lier Phone +32 [3] 491 91 50 Fax +32 [3] 491 91 51 msabelgium@msa.be Italy MSA Italiana Via Po 13/17 20089 Rozzano [MI] Phone +39 [02] 89 217 1 Fax +39 [02] 82 59 228 info-italy@ msa-europe.com Czech Republic MSA Safety Czech Pikartská 1337/7 716 07 Ostrava-Radvanice Phone +420 [59] 6 232222 Fax +420 [59] 6 232675 info@msa-auer.cz Austria MSA AUER Austria Kaplanstrasse 8 3430 Tulln Phone +43 [22 72] 63 360 Fax +43 [22 72] 63 360 20 info@msa-auer.at Great Britain MSA Britain Lochard House Linnet Way Strathclyde Business Park BELLSHILL ML4 3RA Scotland Phone +44 [16 98] 57 33 57 Fax +44 [16 98] 74 0141 info@msabritain.co.uk Sweden MSA NORDIC Kopparbergsgatan 29 214 44 Malmö Phone +46 [40] 699 07 70 Fax +46 [40] 699 07 77 info@msanordic.se MSA SORDIN Rörläggarvägen 8 33153 Värnamo Phone +46 [370] 69 35 50 Fax +46 [370] 69 35 55 info@sordin.se Spain MSA Española Narcís Monturiol, 7 Pol. Ind. del Sudoeste 08960 Sant-Just Desvern [Barcelona] Phone +34 [93] 372 51 62 Fax +34 [93] 372 66 57 info@msa.es Hungary MSA Safety Hungaria Francia út 10 1143 Budapest Phone +36 [1] 251 34 88 Fax +36 [1] 251 46 51 info@msa.hu Romania MSA Safety Romania Str. Virgil Madgearu, Nr. 5 Ap. 2, Sector 1 014135 Bucuresti Phone +40 [21] 232 62 45 Fax +40 [21] 232 87 23 office@msanet.ro Russia MSA Safety Russia Pokhodny Proezd, 14 125373 Moscow Phone +7 [495] 921 1370/74 Fax +7 [495] 921 1368 msa-moscow@ msa-europe.com Switzerland MSA Schweiz Eichweg 6 8154 Oberglatt Phone +41 [43] 255 89 00 Fax +41 [43] 255 99 90 info@msa.ch European International Sales [Africa, Asia, Australia, Latin America, Middle East] MSA EUROPE Thiemannstrasse 1 12059 Berlin Phone +49 [30] 68 86 55 5 Fax +49 [30] 68 86 15 17 contact@msa-europe.com