MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module



Similar documents
Fiber Characterization Service

Acterna OFS-100/-200. Optical results analysis & cable acceptance report generation software ACTERNA TEST & MEASUREMENT SOLUTIONS

JDSU s MTS/T-BERD platforms: Fully automated bi-directional OTDR data acquisition and data analysis test instruments

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

palmotdr Series Handheld OTDR

JDSU NetCompleteTM Metro Ethernet Service Assurance Solution Brochure

OFM-500 Optical Fiber Mapping Software. A complete software application for managing documentation in fiber optic plants

Field Measurements of Deployed Fiber

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

Agilent E6020B FTTx OTDR

MTS-6000 Compact Optical Test Platform

New Installation and Maintenance Tools for CWDM Networks

Tracing Live or Dark FTTx PONs through Splitter using OFL280

How To Use Onmsi For Fiber Optic Network Monitoring System

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

ONMSi: Optical Network Monitoring System

AQ7275 OTDR Optical Time Domain Reflectometer

Removing the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications

OFS AllWave Zero Water Peak (ZWP) single-mode

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Attaching the PA-A1-ATM Interface Cables

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Module 13 : Measurements on Fiber Optic Systems

Gigabit Ethernet Copper-to-Fiber Converters

M310 Data Center OTDR

Fiber Optic Light Sources

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Fiber-to-the-Home/FTTH

DA-3600A Data Network Analyzer Advanced Network analysis and troubleshooting

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS)

Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009

The MTS-8000 Transport Module SDH, PDH, and Ethernet Test Module for the MTS-8000

Designing Fiber Optic Systems David Strachan

Cisco SFP Optics for Gigabit Ethernet Applications

Gigabit Passive Optical Networks

Plug - Type (Male/Female) Attenuators CAA series Singlemode

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance

Wavelength Division Multiplexing

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

Verifying Metro Ethernet Quality of Service

Model GS Port Node 1 GHz with 40/52 MHz split

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Measuring of optical output and attenuation

Installation, Commissioning, and Maintenance of Metro Ethernet Networks Using T-BERD/MTS 8000 and NetComplete (QT-600) Metro Ethernet Service Solution

A Quick Start Guide to Fiber Inspection, Cleaning, and Test INSPECT BEFORE YOU CONNECT SM

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Explanation of Reflection Features in Optical Fiber as Sometimes Observed in OTDR Measurement Traces

FIBER OPTIC SYSTEM TEST PROCEDURES

HST-3000 Handheld Services Tester. Platform Overview

FiberBasix 50 Handheld Testers Series comprising the els-50 light source and epm-50 power meter

Fiber Optic Specifications

Live Fiber Monitoring in CWDM Networks

HP 70950B OPTICAL SPECTRUM ANALYZER

Spectrum and Power Measurements Using the E6474A Wireless Network Optimization Platform

Service Description blizznetdarkfiber

SFP Transceiver Specifications

The Conversion Technology Experts. Fiber Optics Basics

Dispersion in Optical Fibers

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Recession-Proof Consulting Services with CWDM Network Design

Testing Fiber Optic Cables. Rudy De Winter C.N. Rood

FST-2802 TestPad Gigabit Ethernet Services Module Test Ethernet, Fibre Channel, and IP services using one test instrument!

Testing and troubleshooting enterprise fiber-optic cabling. Presenter: Neftali Usabal Fluke Networks - LATAM

Fibre Channel Fiber-to-Fiber Media Converters

TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS

DSAM Digital Quality Index (DQI) A New Technique for Assessing Downstream Digital Services

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Introduction to Optical Link Design

Accurately Testing fibre Optic Cables

How To Use A Network Instrument Ntap

Cable Network Transparency Fiber Optic Monitoring

BLACK BOX Scalable matrix KVM switch supports up to 1024 ports with fiber or copper cable.

Optical Fibers Fiber Optic Cables Indoor/Outdoor

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks

Cisco - Calculating the Maximum Attenuation for Optical Fiber Links

Centralized Remote Testing for DS3/1/0 Based Services. CT650 CENTEST Wideband Test Unit

Optimux-34, Optimux-25

École Supérieure d'optique

Detecting Bridged Tap and Noise Interference in VDSL2 Access Networks using the JDSU SmartClass TPS

Prisma IP 10 GbE VOD Line Card

99 Washington Street Melrose, MA Phone Toll Free Visit us at

ONMSi: Optical Network Monitoring System. Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks

Loss & Continuity Testing with MPO/ MTP Connectors

How To Read A Fiber Optic Sensor

TransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers

HDO700 P FIBRE OPTIC TRANSMITTER

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Detecting faulty fiber with centralized failure detection system (CFDS) in fiber-to-the-home (FTTH) access network

Technical Bulletin. Guidelines For Testing And Troubleshooting Fiber Optic Installations

Optical Power Meter. Specification & User Manual

Interference Analysis

File Transfer Protocol (FTP) Throughput Testing by Rachel Weiss

Transcription:

COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms (VLR) OTDR Module Key Features CWDM/DWDM ready with 1310, 1383, 1490, 1550, and 1625 nm wavelengths FTTx ready with 1310/1490/1550 nm wavelengths 0.8 m event dead zone for highest network precision Point-to-multipoint (P2MP) testing with a combined high dynamic range and high resolution solution In-service testing with the filtered 1625 nm wavelength Identify ITU fiber type (G.65x A, B, C, and D) with water peak detection at 1383 nm Continuous wave (CW) functionality Multi-application optical test module In today s telecommunications market, test solutions must be cost effective, increase productivity, and reduce the complexity of field testing. JDSU s Very Long Range (VLR) OTDR Module offers a high-performance OTDR test module, which has been specifically developed in response to these industry demands. Configurable at the time of order, the VLR OTDR Module offers multiple wavelength test capabilities (1310, 1383, 1490, 1550, and 1626 nm), providing field technicians with an all-in-one test instrument. Traditionally, 45 db OTDRs have been constrained to very long haul testing. The VLR OTDR Module s performance enables effective testing on short haul (access, FTTx, P2MP), long haul, and very long haul networks. WEBSITE: www.jdsu.com/test

2 Test the fiber with the right solution at the right wavelength As fiber installers and technicians continue to look for ways to reduce time and costs during field operation, it is essential for them to use the right tool for the job at hand. The combination of an unprecedented 0.1 s refreshing time, the shortest event resolution (0.8 m event dead zone and 4 m attenuation dead zone), and a 45 db dynamic range, makes the VLR OTDR Module an ideal tool for the qualification of any type of fiber network. A large range of wavelengths is available to best match any application: For metro networks, a four-wavelength (1310/1383/1550/1625 nm) VLR OTDR Module is used for fiber qualification linked to the water peak absorption (according to ITU standards G.652, G.655, and G.656). The VLR OTDR Module is the first commercially available four-wavelength 45 db OTDR in the industry. For access networks, a three-wavelength (1310/1490/1550 nm) VLR OTDR Module is used for fiber qualification at FTTx transmission wavelengths. For in-service testing and troubleshooting of metro and access applications, a dedicated and optimized 1625 nm wavelength is available. A new standard in OTDR performance The VLR OTDR Module is a very high performance OTDR and is capable of characterizing sections of singlemode fiber links that have been illusive in the past. With a 0.8 m event dead zone, it is now possible to qualify and troubleshoot problems in never before investigated sections of the fiber link. Pinpoint any fault in the network. Discriminate a failure or break within the patch panel or distribution frame. Reduce testing time for medium and long haul fiber network commissioning. Obtain a superior and cleaner trace form for high link loss for best fault detection. X 1 m 2 m 6 m Bend Connectors High resolution for detection of bends and close events

3 Improve productivity and efficiency in the field with JDSU s innovative software 3 wavelength OTDR display With the VLR OTDR Module s impressive performance, testing, and troubleshooting capabilities, the amount of time required to characterize a fiber network is drastically reduced. Test any fiber link or network configuration in record time. The VLR OTDR Module configures itself with its automated functionality and sets the best-suited acquisition parameters, including optimized acquisition times, as defined by the instrument. Obtain the trace form with the correct auto zoom, evaluate the fiber link, and save the results in record time! Minimize handling errors with the pass/fail indicator. By viewing a quick snapshot, technicians can easily identify incorrect results. Test through a PON splitter with the best available performance With the combination of an impressive acquisition time, event dead zone, and dynamic range, FTTx technicians are able to test through a splitter with unprecedented accuracy using the VLR OTDR Module. In compliance with ITU-T G.983.3, the VLR OTDR Module provides a three-wavelength version at 1310/1490nm/1550 nm, expanding its test capabilities to FTTx/PON. Provides splice and connector information at the three PON wavelengths. Combines a high dynamic range and short event resolution in order to characterize short fiber lengths and measure through the splitters. Integrates splitter management data in the table results. IP Video Data Voice OLT 1310 nm 1490 nm 1xN Splitter Central Office FTTx/PON network tests

4 One button bi-directional OTDR acquisition and analysis Added to the MTS/T-BERD platforms automated bi-directional OTDR acquisition process, the VLR OTDR Module offers an essential tool for the acceptance testing of new cable deployments. Configuration synchronization at both ends for error-free test setup. Fiber continuity check capability. Automatic measurement procedure with the master-master operation. Exchange results from both ends through the fiber. Pass/fail indication minimizes handling errors. Optical Communication Optical Test Platform Dedicated Fiber for File Transfer Optical Test Platform Optical Communication VLR OTDR Cable Under Test VLR OTDR Automatic Bi-directional OTDR Analysis

5 In-service testing at 1625 nm The VLR OTDR Module includes a filtered 1625 nm wavelength for in-service testing. Raman compensation for high power 1550 nm transmission analysis, including counter- or co-propagation signal management. More robust for high power CW transmission signal influence. VLR OTDR Module 1625 nm test wavelength λ traffic λ test + λ traffic Tx Rx Optical Network Under Test: Point-to-Point Point-to-Multipoint Water peak detection at 1383 nm for CWDM applications Since legacy fibers have high attenuation values in the 1383 nm region, loss results must be verified using the VLR OTDR Module. 5 4 Attenuation (db/km) 3 2 1 0 OH-Absorption Peak 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 Wavelength (μm) Low water peak fiber

6 Error-free professional report generation A complete PC-based software application within a Microsoft Windows environment offers detailed generation of professional OTDR trace reports. Proof-of-performance reports with a high degree of customization capabilities. Dedicated tables are provided for each test result (splice loss, connector, and length). Out-of-range value summaries are provided with analysis of macro-bends. Compare results between the different wavelengths to identify bends and constraints. Complete fiber characterization reports, including OTDR, CD, PMD, and spectral attenuation. Example of test report MTS/T-BERD 8000 platform with OTDR and OFI modules Enhanced testing solution With the scalable design of the MTS/T-BERD platforms, field technicians can quickly and easily plug-in the appropriate test module to perform precise measurement from the outside plant to the central office. The optical test platforms offer a full range of fiber characterization test modules with OTDR, CD, and spectral attenuation measurement, as well as DWDM testing capabilities. With this new VLR OTDR Module and the current range of available OTDR modules, JDSU s test solution is the broadest offering on the market, making JDSU the provider of choice for all telecommunications operators and fiber optic installers. The VLR OTDR Module can be combined with additional measurement capabilities in JDSU s optical test platforms so that technicians can fully characterize the fiber network with an all-in-one solution: Optical insertion loss Optical return loss OTDR Chromatic dispersion Polarization mode dispersion Spectral attenuation profile

Specifications General (typical at 25 C) Weight Dimensions (w x h x d) 0.6 kg (1.1 lb) 213 x 124 x 32 mm (8.38 x 4.88 x 1.26 in) Optical Interfaces Applicable fiber SMF 9/125 µm Interchangeable optical connectors FC, SC, DIN, ST, LC Technical Characteristics Laser safety class (21 CFR) Class 1 Distance units Kilometers, feet, and miles Group index range 1.30000 to 1.70000 in 0.00001 steps Number of data points Up to 128,000 data points Distance measurement Automatic or dual cursor Display range From 2.6 m up to 380 km Cursor resolution 1 cm Sampling resolution 4 cm Accuracy ±1 m ±sampling resolution ±1.10-5 x distance (Excluding group index uncertainties) Attenuation Measurement Automatic, manual, 2-point, 5-point, and LSA Display range 1.25 db to 55 db Display resolution 0.001 db Cursor resolution 0.001 db Linearity ±0.03 db/db Threshold 0.01 to 5.99 db in 0.01 db step Reflectance/ORL Measurements Display resolution 0.01 db Threshold -11 db to -99 db in 1 db step Reflectance accuracy ±2 db Ordering Information 1625 nm OTDR Module E8117RVLR 1310/1550 nm OTDR Module E8126VLR 1550/1625 nm OTDR Module E8129VLR 1310/1550/1625 nm OTDR Module E8136VLR 1310/1490/1550 nm OTDR Module E8138VLR49 1310/1383/1550/1625 nm OTDR Module E8148VLR38 Continous Source option E80OTDRLS Universal Optical Connectors Straight connectors EUNIPCFC, EUNIPCSC, EUNIPCST, EUNIPCDIN, EUNIPCLC 8 angled connectors EUNIAPCFC, EUNIAPCSC, EUNIAPCST, EUNIAPCDIN, EUNIAPCLC For more information on the MTS/T-BERD platforms, test modules, adapters, cables, and fiber optic couplers, refer to the separate datasheets and brochures. OTDR Module Technical Specifications (typical at 25 C) These are standard specifications, representing only a selection of JDSU s offerings. For specific requirements, please contact your local JDSU representative. Central Wavelength 1 Pulse Width RMS Dynamic Range 2 Event Dead Zone 3 Attenuation Dead Zone 4 Continuous Wave Output Power Application 1310 ±20 nm 3 ns to 20 µs 45 db 0.8 m 4 m 0 dbm FTTx through splitters/metro/ Long Haul 1383 ±2 nm 44 db 1490 ±15 nm 42 db 1550 ±20 nm 43 db 1625 ±10 nm 43 db 1 Laser at 25 C and measured at 10 µs for singlemode and 50 ns for multimode 2 The one way difference between the extrapolated backscattering level at the start of the fiber and the RMS noise level, after 3 minutes averaging and using the largest pulsewidth 3 Measured at ±1.5 db down from the peak of an unsaturated reflective event using the shortest pulsewidth 4 Measured at ±0.5 db from the linear regression using a FC/UPC reflectance and using the shortest pulsewidth All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. The user assumes all risks and liability whatsoever in connection with the use of a product or its application. JDSU reserves the right to change at any time without notice the design, specifications, function, fit or form of its products described herein, including withdrawal at any time of a product offered for sale herein. JDSU makes no representations that the products herein are free from any intellectual property claims of others. Please contact JDSU for more information. JDSU and the JDSU logo are trademarks of JDS Uniphase Corporation. Other trademarks are the property of their respective holders. 2007 JDS Uniphase Corporation. All rights reserved. 30137529 003 1007 VLROTDRMODULE.DS.FOP.TM.AE Test & Measurement Regional Sales NORTH AMERICA TEL: 1 866 228 3762 FAX: +1 301 353 9216 LATIN AMERICA TEL: +55 11 5503 3800 FAX: +55 11 5505 1598 ASIA PACIFIC TEL: +852 2892 0990 FAX: +852 2892 0770 EMEA TEL: +49 7121 86 2222 FAX: +49 7121 86 1222 www.jdsu.com/test