Model UT201/202: OPERATING MANUAL. Table of Contents



Similar documents
UT202A Operating Manual. Contents

Model UT33A: OPERATING MANUAL Table of Contents (1)

Model UT33B/C/D: OPERATING MANUAL Table of Contents (1)

Model UT58A/B/C: OPERATING MANUAL

Table of Contents. Page

Model UT60A: OPERATING MANUAL. Table of Contents. Page

Model UT713 OPERATING MANUAL

Model UT61A/61B/61C/61D/61E: OPERATING MANUAL. Table of Contents

Intelligent Digital Multimeters

10 Multimeter. Users Manual

Model UT71A/B OPERATING MANUAL

User Guide. Model Insulation Tester / Megohmmeter

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Manual Ranging MultiMeter

AutoRanging Digital MultiMeter

User's Guide. True RMS Industrial Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

7 FUNCTION DIGITAL MULTIMETER

Seven function digital multimeter

HVAC Clamp Meter. Users Manual

i410/i1010 AC/DC Current Clamp

How To Use A Cdm250 Digital Multimeter

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

DIGITAL MULTIMETER OPERATION MANUAL ITEM DIGITAL MULTIMETER CONTENTS

User Guide. 4 wire Earth Resistance Tester Model GRT300

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions

Table of Contents. The Basics of Electricity 2. Using a Digital Multimeter 4. Testing Voltage 8. Testing Current 10. Testing Resistance 12

ABCs of DMMs Multimeter features and functions explained Application Note

Ground Resistance Clamp On Tester

Instruction Manual IDM 71/72/73 Digital Multimeter EN FR IT DE

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

323/324/325. Calibration Manual. Clamp Meter

Instructions A Amp AC/DC Current Probe

115C and 117C. True-rms Multimeters. Users Manual

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

HOW TO USE MULTIMETER. COMPILE BY: Dzulautotech

1587/1577. Insulation Multimeters. Users Manual

MEGGER Insulation & Low Resistance Tester

AVO410. Digital multimeter Digitale Multimeter Multimèter numérique Multímetro digitales Digitale multimeter

AMP-210 AMP-210-EUR AMP-220 AMP-220-EUR AMP-310 AMP-310-EUR AMP-320 AMP-320-EUR. 600A AC TRMS Clamp Multimeter. 600A AC / DC TRMS Clamp Multimeter

What is a multimeter?

Model 1756 Test Lead Kit

RS DIGITAL THERMOMETER

Model 77 Series IV Digital Multimeter

Essential Electrical Concepts

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

INTRODUCTION SAFETY PRECAUTIONS/

Dual Display Digital Multimeter

The Basics of Digital Multimeters

User s Manual Before using the inverter, you need to read and save the safety instructions.

Ground Resistance Clamp-On Tester

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Microwave Meter. Instruction Manual

ADM1TE 5/30A DIN rail single phase two wire energy meter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Integrating Sound Level Meter and Datalogger

INSTRUCTION MANUAL IPM Phase Power Analyser EN FR IT DE ES

LITHIUM BATTERY CR123A SPECIFICATION

RIGOL. Quick Guide. DS1000CA Series Oscilloscope. Aug RIGOL Technologies, Inc.

12 Volt 30 Amp Digital Solar Charge Controller

AGILENT E5071C ENA NETWORK ANALYZER

Getting started with

Model 187 & 189. Users Manual. True RMS Multimeter

Agilent U1610/20A Handheld Digital Oscilloscope Quick Start Guide

Table of Contents. Title

Table of Contents. Page No.

Hygro-Thermometer + InfraRed Thermometer Model RH101

Thermistor Thermometer MODEL NO

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

PR-D9W. GB Version 1

Temperature Humidity Meter

Fig. 1 Analogue Multimeter Fig.2 Digital Multimeter

RADIANT PLASMA 4700 Plasma Spark Generator

Building the HVPS High Voltage Power Supply

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

DC POWER SUPPLY ALIMENTATION C.C.

Owner s Manual

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

TIG INVERTER INSTRUCTION MANUAL

Digital Photo Picture Frame. Operation Manual

Power Supplies. 1.0 Power Supply Basics. Module

ANADOLU UNIVERSITY DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Power Supplies. Overview. Measuring Electricity. Understanding Electricity. Two Types of Current. Powering the PC

Achat 115MA full-range speaker. user manual

How To Use A Meter

Test Before Touch Easier Said Than Done. Ken Crawford, DuPont Kent Haggerty, Dupont

POWER SUPPLY MODEL XP-15. Instruction Manual ELENCO

Talon VFD / Inverter Meter

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

Operating Manual Remote Cost Control Monitor

ECEN 1400, Introduction to Analog and Digital Electronics

Charge Regulator SCR 12 Marine

Thermocouple Thermometer Models

Transcription:

Table of Contents Title Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Rotary Switch Functional Buttons The Effectiveness of Functional Buttons Display Symbols Measurement Operation A. DC Voltage Measurement B. AC Voltage Measurement C. Measuring Resistance D. Testing Diodes E. Testing for Continuity F. Temperature Measurement G. AC Current Measurement Sleep Mode Specifications A. General Specifications B. Environmental Restriction Accuracy Specifications A. AC Voltage B. DC Voltage C. Resistance D. Continuity Test E. Diode Test F. Temperature G. AC Current Maintenance A. General Service B. Replacing the Battery Page 3 4 5 6 8 9 10 11 12 13 15 15 16 17 19 20 22 23 25 26 26 26 27 27 27 28 28 28 29 29 30 30 30 1

2

Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly. Warning To avoid electric shock or personal injury, read the Safety Information and Rules for Safe Operation carefully before using the Meter. Digital Multimeter Model UT201/202 (hereafter referred to as the Meter ) are 3 1/2 digits with steady operations, fashionable structure and highly reliable measuring instrument. The Meter uses large scale of integrated circuit with double integrated A/D converter as its core and has full range overload protection. The Meter can measure AC/DC Voltage, AC Current, o Resistance, Temperature( F/ o C), Diodes, Continuity and so on. 3

Unpacking Inspection Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part: Item 1 2 3 Description English Operating Manual Qty 1 piece 1 pair 1 piece Test Lead Point Contact Temperature Probe (UT202 only) 4 1.5V Battery (AAA) 2 pieces In the event you find any missing or damage, please contact your dealer immediately. 4

Safety Information This Meter complies with the standards IEC61010: in pollution degree 2, overvoltage category (CAT. II 600V, CAT. III 300V) and double insulation. CAT. II: Local level, appliance, PORTABLE EQUIPMENT etc., with smaller transient overvoltages than CAT. III. CAT. III: Distribution level, fixed installation, with smaller transient overvoltages than CAT. IV Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired. In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test. A Note identifies the information that user should pay attention to. International electrical symbols used on the Meter and in this Operating Manual are explained on page 8. 5

Rules For Safe Operation (1) Warning To avoid possible electric shock or personal injury, and to avoid possible damage to the Meter or to the equipment under test, adhere to the following rules: Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Pay attention to the insulation around the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads with identical model number or electrical specifications before using the Meter. Do not apply more than the rated voltage, as marked on the Meter, between the terminals or between any terminal and grounding. If the value to be measured is unknown, use the maximum measurement position and reduce the range step by step until a satisfactory reading is obtained. When measurement has been completed, disconnect the connection between the test leads and the circuit under test, remove the testing leads away from the input terminals of the Meter and turn the Meter power off. The rotary switch should be placed in the right position and no any changeover of range shall be made during measurement is conducted to prevent damage of the Meter. Do not carry out the measurement when the Meter s back case and battery compartment are not closed to avoid electric shock. Do not input higher than 600V between the Meter s terminals and the grounding to avoid electric shock and damages to the Meter. 6

Rules For Safe Operation (2) When the Meter working at an effective voltage over 60V in DC or 30V rms in AC, special care should be taken for there is danger of electric shock. Use the proper terminals, function, and range for your measurements. Do not use or store the Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened. When using the test leads, keep your fingers behind the finger guards. Disconnect circuit power and discharge all high -voltage capacitors before testing resistance, continuity and diode. Replace the battery as soon as the battery indicator appears. With a low battery, the Meter might produce false readings that can lead to electric shock and personal injury. When servicing the Meter, use only the same model number or identical electrical specifications replacement parts. The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter and any accident. Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. The Meter is suitable for indoor use. Turn the Meter off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter. 7

International Electrical Symbols AC (Alternating Current). DC (Direct Current). AC or DC. Grounding. Double Insulated. Deficiency of Built-In Battery Continuity Test. Diode. Capacitance Test Fuse. Warning. Refer to the Operating Manual. Conforms to Standards of European Union. 8

The Meter Structure (see figure 1) ( figure 1) 1. Input Terminals 2. LCD Display 3. Functional Buttons 4. Rotary Switch 5. Trigger: press the lever to open the transformer jaws. When the pressure on the lever is released, the jaws will close. 6. Hand Guards: to protect user s hand from touching the dangerous area. 7. Transformer Jaws: designed to pick up the AC current flowing through the conductor. It could transfer current to voltage. 9

Rotary Switch Below table indicated for information about the rotary switch positions. Rotary Switch Position OFF Ω o C o F Function Power is turned off. AC/DC voltage measurement. : Diode test. Ω : Continuity test. : Resistance measurement. Temperature measurement (UT202 only) A AC current measurement range from 0.001A to 400.0A 10

Functional Buttons(1) Below table indicated for information about the functional button operations. AC HOLD MAX SELECT voltage measurement. Press HOLD to enter and exit the Hold mode in any mode, the Meter beeps. Press and hold HOLD button while turning on the Meter to display full icons. Press MAX to start recording and updating of maximum values. Press SELECT button to switch between o Ω and C o F. 11

The Effectiveness of Functional Buttons Not every functional buttons can be used on every rotary switch positions. Below two tables describe which functional buttons can be used on which rotary switch positions Model: UT201 Rotary Switch Positions A A V V Functional Buttons SELECT MAX HOLD N/A N/A Ω N/A N/A 2/20A N/A 200/400A N/A N/A Model: UT202 Rotary Switch Positions V V Ω Functional Buttons SELECT MAX HOLD N/A N/A o F o C(K-Type) A 2/20A N/A A 200/400A N/A N/A N/A 12

Display Symbols(1) (see figure 2) No. Symbol Meaning 1 AC Indicator for AC voltage or current 2 DC Indicator for DC voltage The battery is low. Warning: To avoid false readings, 3 which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator appears. The Meter is in the auto range mode 4 in which the Meter automatically selects the range with the best resolution. 5 Test of diode. 6 The continuity buzzer is on. 7 MAX Maximum reading displayed 8 Date hold is active. 9 o C o F 10 Ω,kΩ,MΩ 13

Display Symbols(2) (see figure 2) No. Symbol Meaning 11 A Amperes (amps). The unit of current. 12 mv, V Volts. The unit of voltage.mv: Millivolt. 1x10-3 or 0.001 volts 13 Indicates negative reading 14 OL The input value is too large for the selected range 14

Measurement Operation(1) A. DC Voltage Measurement (see figure 3) red black ( figure 3) Warning To avoid harms to you or damages to the Meter from eletric shock, do not attempt to measure voltages higher than 600V AC/DC, although readings may be obtained. The DC Voltage ranges are: 200.0mV, 2.000V, 20.00V, 200.0V and 600V. To measure DC voltage, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch to V. 3. Connect the test leads across with the object being measured. The measured value shows on the display. Note In each range, the Meter has an input impedance of 10MΩ. This loading effect can cause measurement errors in high impedance circuits. If the circuit impedance is less than or equal to 10kΩ, the error is negligible (0.1 or less). 15

Measurement Operation(2) When DC voltage measurement has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals. B. AC Voltage Measurement (see figure 4) red black ( figure 4) Warning To avoid harms to you or damages to the Meter from eletric shock, do not attempt to measure voltages higher than 600V AC/DC, although readings may be obtained. 16

Measurement Operation(3) Note In each range, the Meter has an input impedance of 10MΩ. This loading effect can cause measurement errors in high impedance circuits. If the circuit impedance is less than or equal to 10kΩ, the error is negligible (0.1 or less). When AC voltage measurement has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals. C.Measuring Resistance (see figure 5) red black ( figure 5) Warning To avoid harms to you, do not attempt to input voltages higher than 60V DC or 30V rms AC. To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring resistance. 17

Measurement Operation(5) D.Testing Diodes (see figure 6) red black ( figure 6) Warning To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before testing diodes. Use the diode test to check diodes, transistors, and other semiconductor devices. The diode test sends a current through the semicondutor junction, then measure the voltage drop across the junction. A good silicon junction drops between 0.5V and 0.8V. To test the diode out of a circuit, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch toω and press SELECT button to select measurement mode. 3. For forward voltage drop readings on any semiconductor component, place the red test lead on the component s anode and place the black test lead on the component s cathode. 19

Measurement Operation(6) Note In a circuit, a good diode should still produce a forward voltage drop reading of 0.5V to 0.8; however, the reverse voltage drop reading can vary depending on the resistance of other pathways between the probe tips. Connect the test leads to the proper terminals as said above to avoid error display. The LCD will display OL indicating either open circuit or wrong polarity connection. The unit of diode is volt (V), displaying the forward voltage drop readings. To remove the objects being tested from the circuit when measuring can obtain a more accurate result. When diode testing has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals. E.Testing for Continuity (see figure 7) red black ( figure 7) 20

Measurement Operation(7) Warning To avoid damages to the Meter or to the devices under test, disconnect circuit power and discharge all the high-voltage capacitors before measuring continuity. To test for continuity, connect the Meter as follows: 1. Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal. 2. Set the rotary switch to Ω and press SELECT button to select measurement mode. 3. The buzzer sounds if the resistance of a circuit under test is less than 50 Ω. 4. The buzzer may or may not sounds if the resistance of a circuit under test is between 50 Ω to 120 Ω. 5. The buzzer does not sound if the resistance of a circuit under test is higher than 120Ω. Note The buzzer beeps once when pressing any buttons at any rotary switch positions except at 2/20A positions if the button is valid. If the button is not valid, it does not beep. At 2/20A rotary switch position, the buzzer is set not to beep. The buzzer beeps 5 times continuously on around 1 minute before entering the sleep mode. When it is just before entering the sleep mode, it will have one long beep to warn you. The LCD displays OL indicating the circuit being tested is open. When continuity testing has been completed, disconnect the connection between the testing leads and the circuit under test and remove testing leads from the input terminals. 21

Measurement Operation(8) F. Temperature Measurement (UT202 Only) (see figure 8) red black ( figure 8) The temperature measurement ranges are -40 o C~1000 o C and -40 o F~1832 o F. To measure temperature, connect the Meter as follows: 1. Insert the red temperature probe into the VΩ terminal and the black temperature probe into the COM terminal. 2. Set the rotary switch to o F o C and press SELECT button to select o F or o C measurement mode. o C measurement mode is default. 3. Place the temperature probe to the object being measured. The measured value shows on the display. Note The Meter automatically displays the temperature value inside the Meter when there is no temperature probe connection. When temperature measurement has been completed, disconnect the connection between the temperature probe and the circuit under test, and remove the temperature probe away from the input terminals of the Meter. 22

Measurement Operation(9) G. AC Current Measurement (see figure 9) ( figure 9) Warning To avoid electric shock, never measure current while the test leads are inserted into the input terminals and disconnect test leads and tested circuit connection. Never attempt an in-circuit current measuremnet where the open-circuit voltage between the circuit and the ground is greater than 600V Use proper function and range for the measurement. The measuremnet ranges of current are: 2.000A, 20.00A, 200.0A and 400A. To measure current, do the following: 1. Set the rotary switch to 2/20A or 200/400 A 2. Press the lever to open the transformer jaws. 3. Center the conductor within the transformer jaw. The measured value shows on the display, it is a effective value of sine wave (mean value response). 23

Measurement Operation(10) Note: To obtain accurate reading, measure only one conductor at each time. When current measurement has been completed, disconnect the connection between the conductor under test and the jaw, and remove the conductor away from the transformer jaw of the Meter. 24

Copyright 2001 Uni-Trend International Limited. All rights reserved. Manufacturer: Uni-Trend International Limited Rm901, 9/F, Nanyang Plaza 57 Hung To Road Kwun Tong Kowloon, Hong Kong Tel: (852) 2950 9168 Fax: (852) 2950 9303 Email: info@uni-trend.com http://www.uni-trend.com 32