DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS



Similar documents
Section TELEPHONE AUTOMATIC DIALER SYSTEM

RACO DATA ACQUISITION SYSTEM SPECIFICATIONS December

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

K-2000-DVA See at a Glance when Lines are Multi-Input Ringing Voice. Telecommunication Peripheral Products. Technical Practice

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

United Security Products Automatic Dialers are a NEW BREED of Security

TELULAR SX4E PHONECELL WITH THE 8210 SPEECH MODEM APPLICATION NOTE

The Bizfon is sold direct through the web site, through our telephone sales division and through our dealer network.

APPLICATION SUPPORT BULLETIN

ACE AUTODIALLER MANUAL FOR LIFT COMPANY

Centrepoint Technologies. Phone System Solutions for: Smart homes Home businesses Small offices Branch/Remote offices DESKTOP PHONE SYSTEM.

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Temperature & Humidity SMS Alert Controller

THE TOWN OF GROTON IS REQUESTING PROPOSALS FOR A WIRELESS ALARM MONITORING AND CONTROL SYSTEM WITH INTERNET BASED DATA ACCESS

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

LYNX. The Best in Wireless Home Security...

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

PagePac PAGEPAL V

Features Voice Mail System

Using your LED Plus keypad

SECTION DETECTION AND ALARM

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Alliance System Ordering Guide

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Destiny Destiny Owners Manual

Control/Communicator Installation Manual

INTRUSION DETECTION SYSTEM Section

GSM Alarm System User Manual

AUTODIALLER / QUICKDIALLER - SA132

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Back-UPS Pro 1300/1500 Installation and Operation

E-969 ENCODER. Outdoor Warning. Installation & Operating Manual E-969 E STAND BY MODE MONDAY 01:45:02 SEND ENGINEERING COMPANY INC.

SpotCell Automatic Dialer System

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Expansion Modules & Accessories

Personal Assistance System Owner's Guide

FortiVoice. Version 7.00 User Guide

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

SMS GSM Alarm Messenger

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

CHAPTER 1. GETTING STARTED... 1

Installation and Operation Back-UPS 1250, 1300, 1500

Program Entry Guide. Control Panels

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Digital and Analog I/O

GSM Autodialer Professional GJD700 Speech & Text Autodialer

CC Family of Data Collectors

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Automatic Telephone Dialer TD-101(W)

United Security Products Model AVD-45b Automatic Voice Dialer Installation and Instruction Manual

Modem and Local Area Networks. Document Part Number:

NETWORK ENABLED EQUIPMENT MONITOR

Announcement, Call Processing and Music/Messaging-On-Hold System

Voice Dialer Alarm System Installation Manual DA-712K

User manual Rev 1.3 Contents

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

MN3310 Evaluation Kit v1 User Guide

MN1010 Evaluation Kit v3 User Guide

Model PBX816ex. Programming & User Guide

HA ZONE ALARM CONTROL PANEL OWNER'S MANUAL. Programming And Operation FOR HOME AND OFFICE PROTECTIONS WITH AUTO-DIALER AND COMMUNICATOR

HP UPS R1500 Generation 3

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

ADEMCO 4500 Thermostat

AGRI-ALERT 800T / AGRI-ALERT 800 ALARM SYSTEM USER MANUAL

ABUS WIRELESS ALARM SYSTEM

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

Crow Limited Warranty. Print Version 017

Export: Exporting the call log or Voice Mail messages from the Viewer software is not supported.

PERS-2400B PERSONAL EMERGENCY REPORTING SYSTEM. Installation, and Operation Instructions

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

PROGRAMMING GUIDE. XR6 COMMAND PROCESSOR PANEL and XR10 COMMAND PROCESSOR PANEL

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

SPECIAL CONTROL BUTTON FUNCTIONS

ICP-CC404 ICP-CC404 EN. Control Panel. User s Guide

When you consider how important your communications system is to your business, it is important to remember that the very next phone call you receive

1. Power Light: indicates whether AC power is available to the unit. 2. DS (Downstream): indicates downstream connectivity

SCORPION. micron security products

Modem and Local Area Network

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

SVMi-4 & SVM-400. Voice Mail System. System Administration Manual

Memcom Emergency Telephone

Printed in China. Issue 1.2 AT&T 03/07. Advanced American Telephones. AT&T and the AT&T logo are trademarks of AT&T Knowledge Ventures, licensed to

User's Guide. Integrating Sound Level Datalogger. Model Introduction

ICP-CC488 ICP-CC488 EN. Control Panel. Quick Reference Guide

Control and Remote Supervision of Sewage Pump Station. AutoLog GSM-RTU and AutoLog ControlMan Web-SCADA Service. Specification V1.

Wireless AUTODIAL GSM SMS Home Alarm Security System 900/ 1800/ 1900Mhz(CK-GSM-9003)

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

Automatic Phone-Out Home Monitoring Systems

PDA Software Manual For the Windows CE and Mobile Operating Systems

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

Commander 2000 Control Panel

DESTINY OWNER S MANUAL

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Disturbance Recoder SPCR 8C27. Product Guide

S4000TH HART. HART Communication Manual

Transcription:

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS 1. Description and Phone Number Dialing: The dialer shall be a solid state component capable of dialing up to 16 telephone numbers, each up to 60 digits in length. Phone numbers and Standard pulse dialing or Touch Tone DTMF dialing are user programmable via the system s keyboard or remotely via Touch Tone telephone. In addition, the dialer shall: A. Group Alarm Calls - On alarm, system shall selectively call the correct phone number according to the specific alarm(s). B. Detect Telephone Line Fault and indicate condition with Front Panel LED. C. Automatically select Tone versus Pulse Dialing. D. Monitor Call Progress - Detect Busy and Ringing Signals, Abandon Call if Busy, Wait until phone is answered to Annunciate Voice Reports. E. Provide Numeric Pager Support F. Provide PBX Support 2. Solid State Voice Message Recording and Playback: The unit shall have two different categories of speech message capability, all implemented with permanent non-volatile solid state circuitry with no mechanical mechanisms. The unit shall allow for message recording from a remote telephone as well as from the front panel. A. User Field Recorded Messages: The user may record and re-record his own voice messages for each input channel and for the Station ID. a. There shall be no limit on the length of any particular message within the overall available message recording time, which shall vary from 26 to 635 seconds, depending upon the number of input channels selected, and the recording rate used. b. The unit shall allow selective recording of both Normal and Alarm advisory messages for each input channel. c. The unit shall provide for automatic setting of the optimum speech recording rate for the total set of messages recorder, in order to achieve optimum recording sound quality. d. Circuit board switches or jumper straps shall not be an acceptable means of manipulating message length or recording rates.

B. User Field Recorded Messages: Permanent built-in messages shall be included to support user programming operations, to provide supplemental warning messages such as advising that the alarms have been disabled, and to allow the unit to be fully functional even when the installer has not recorded any messages of his own. 3. Input Monitoring Function: The basic unit shall continuously monitor the presence of AC power and the status of four (4) contact closure inputs. AC power failure, or violation of the alarm criteria at any input shall cause the unit to go into alarm status and begin dial-outs. The unit shall, upon a single program entry, automatically accept all input states as the normal non-alarm state, eliminating possible confusion about Normal Open versus Normally Closed inputs. Further, as a diagnostic aid, unit shall have the capability of directly announcing the state of any given input as currently Closed Circuit or Open Circuit without disturbing any message programming. Each input channel shall also be independently programmable, without the need to manipulate circuit board switches or jumpers, to any of the following: A. Normally Open, Normally Closed, or for No Alarm (Status Only). B. Run Time Meter - to accumulate and report the number of hours a particular input circuit has been closed. Any channel so configured will never cause an alarm call; rather, on inquiry it will recite its message according to the status of the input and then report the closed circuit time to the tenth of an hour. The input will accumulate and report in tenths of hours up to a total accumulated running time of 99,999.9 hours. The initial value of the Run Time Meter shall be programmable in order to agree with existing electromechanical Run Time Meters. Up to a total of eight Run Time Meters may be programmed. C. Pulse Totalizer - to count the accumulated number of pulses (momentary contact closures) occurring at the input so programmed. Any input channel may be programmed for a Totalizer Function, up to a maximum of eight. Maximum Input pulse rate is 100 Hz, with a 50% Duty Cycle. The spoken scaled value will not rollover to zero until a value of 4,294,967,294 has been exceeded. 4. Input/Output Expansion Capability: The standard unit shall be modular in design, permitting it, therefore, to accept plugin expansion circuit boards to incorporate any of the following: A. Contact Closure Expansion Capability to a total of 8, 16, 24, or 32 total dry contact inputs. B. Analog Input Capability to a total of 1, 4, 8, or 16 total analog inputs. C. Remote Supervisory Control Outputs to manipulate 4 or 8 output relays. 5. Modbus Communications: The unit shall accept an expansion card which enables it to communicate directly with devices utilizing Modbus RTU Protocol. A unit so configured shall be capable of reading and writing to 32, 64, or 96 data registers via Touch Tone Telephone. No modem or host computer shall be required. Interface shall consist of a single RS-232.

6. Printer/Computer Communications: The unit shall be equipped with a centronics parallel printer port, enabling the user to print alarm reports, download programming data, and generate scheduled status reports as required. Alternatively, the unit shall be able to accept an optional modular, plug-in asynchronous communications card to permit any of the following: A. Local Data Logging - Permits a single dialer to communicate with a local Serial printer to log routine status reports, alarm reports, and programming data. B. Central Data Logging - Permits one or more dialers to communicate with a single centrally located Serial printer equipped with a suitable modem to log routine status reports, alarm reports, and programming data. C. Data Acquisition and Control - Permits one or more dialers to communicate with a centrally located Computer/Printer System equipped with a SCADA software package, thereby functioning as a stand-alone SCADA system. 7. Alarm and Inquiry Messages: Upon initiating an alarm call, the system is to speak only those channels which are currently in alarm status. Inquiry phone calls can be made directly to the unit at any time for a complete status report. 8. Acknowledgement: Alarms are acknowledged either by pressing a Touch Tone 9 as the call is being received, or by calling the unit back after having received an alarm call. 9. Nonvolatile Program Memory Retention: User-entered programming and voice messages shall be kept intact, even during power failures or when all power has been removed, for up to ten (10) years. This shall be accomplished through inclusion in the system of a lithium battery separate from the unit s backup rechargeable gel cell battery. 10. Local and Remote Programming Capabilities: The user may optionally elect to alter the following parameters from their standard normal default values via keyboard entry or remotely from any Touch Tone telephone. A. Alarm Response Delay: 0.1 to 999.9 seconds, with different delays being assignable to different alarms. B. Delay Between Alarm Call-outs: 0.1 to 99.9 minutes. C. Alarm Reset Time: 0.1 to 99 hours, or No Reset. D. Incoming Ring Response (Answer) Delay: 1 to 20 Rings. E. Number Of Message Repetitions: 1 to 20 Repetitions. F. Autocall Test: When enabled, the unit shall place a single round of test calls, both at the time this function is enabled, and also at regular subsequent intervals until this function is disabled. G. Remote System Microphone Activation. H. Remote Arming and Disarming of System.

11. Phone Line: The dialer is to use a standard dial-up telephone line (direct leased line is not required), and is to be F.C.C. approved. Connection to the telephone is through a 4- pin modular jack (RJ 11). 12. Speakerphone: The unit shall be capable of dialing any phone number on command and functioning as a speakerphone. 13. Real Time Clock: The unit shall be equipped with a real time clock thereby making the following possible: A. Alarm Ready Schedule - The dialer shall be user programmable to follow a specific schedule of operations. This shall include the flexibility to set a weekday, weekend, and holiday schedule. With this feature the dialer shall arm and disarm itself according to the schedule programmed. B. In the event any of the printer configurations outlined in Section 6 are utilized, all alarm reports will be time and date stamped. Routine scheduled status reports can also be programmed. 14. Power/Battery Backup: Normal power shall be 105-135 VAC, 15 watts nominal. The product is to contain its own gel cell rechargeable battery which is automatically kept charged when AC power is present. The system shall operate on battery power for a minimum of 20 continuous hours in the event of AC power failure. A shorter backup time shall not be acceptable. The built-m charger shall be precision voltage controlled, not a trickle charger, in order to minimize recharge time and to maximize battery life available. 15. Integral Surge Protection: All power, phone line. dry contact. and analog signal inputs shall be protected at the circuit board to IEEE Standard 587. category B(6,000 volts open circuit/3,000 amps closed circuit). Gas tubes followed by solid state protectors shall be integral to the circuit board for each line. 16. Technical/Customer Support: All users shall be provided and/or shall have access to the following support resources. A. Each autodialer shall be shipped with a CD_ROM which details all features of the product and provides an in-depth step-by-step video programming guide. A superficial marketing overview will not be acceptable. B. Free Live Chat support on RACO s website staffed with trained technicians shall be available during manufacturer s normal working day. C. Free comprehensive web-based support center with over 550 FAQs shall be available for customers to retrieve copies of all available technical information directly into his own computer. The support center shall have an optimized user interface for smartphones at http://www.racomobilesupport.com, allowing users to quickly navigate to the desired support topics. This service shall be available on a 24 hour basis.

D. A toll free 800 number shall be available during manufacturer s normal working day to permit users to talk directly with technical service personnel and resolve problems not solved by the RACO web-based Support Center. 17. Warranty: The dialer shall be covered by a five (5) year warranty covering parts and labor performed at the factory. 18. Additional Features: Sealed Switches. LED Indicators. Alarm Disable Warning. Talkthrough: All keyboard and front panel switches shall be sealed to prevent contamination. Front panel LED s shall indicate: Normal Operation, Program Mode, Call-in Progress, Status for each Channel, AC Power present, AC Power failure, and Low, Discharging, or Recharging Battery. On any inquiry telephone call, or On-Site status check, the voice shall provide specific warning if no dialout phone numbers are entered, or if the unit is in alarm disabled mode, or if AC power is off or has been off since last reset. A built-in microphone shall allow anyone at a remote site to listen to local sounds and to have a two-way conversation with personnel at the dialer. 19. Miscellaneous Special Order Items: The following options shall be available on specific order: A. Radio Communications Interface B. Various NEMA 4X (sealed) Enclosures C. Thermostatically Controlled Heater D. UL Approved Power Supply E. Cellularm Communications Systems Specifications subject to change without notice. Literature code 116