SL42: Smart lighting controllers installation in the pole SL42 controllers can drive electronic ballasts (DALI or 1 10V), magnetic ballasts in ON/OFF or in dimming. Based on LonWorks protocol, open and interoperable (open system), they can operate in autonomous mode or integrated into a remote management system to the lighting point. OPERATING PRINCIPLE 1) SL42 smart lighting controller Communicates on LON network (LON node ) Allows control of ballasts into the pole (dimming and failure detection) Works independently or integrated into a remote management system 2) The segment controller (i LON from Echelon) installed into the cabinet SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 1/7
Communicates with all LonWorks nodes on power line, two way (up to 150 nodes per segment controller). Saves data Sends data to the monitoring software Operates independently (includes a hourly command an astronomical clock) or controlled by an external supervision software, via a GPRS / ADSL / Wifi / Radio connection (failure management, history ). 3) Remote management software allows to configure and commission network collects, aggregates and manage data without human intervention from hundreds of segment controllers gives access to all web driving applications (detection and failure analysis, historiated curves, alarms management, "real time" analysis of energy consumption...) MEDIA AND COMMUNICATION NETWORK LonTalk protocol. Communication in open and interoperable LonWorks network (ISO/IEC 14908). Media : PLC, Powerline : to transmit information via existing electrical network without additional wiring. (most suitable solution so that all equipment, even from different manufacturers, can communicate together through electrical network). Protocol developed by Echelon : optimization of communication paths on the CPL media. Warranty of constant communication between segment controller (Echelon i.lon) and Citylone lighting controllers. SL42 DESCRIPTION Functions : Drives and controls any type of ballast (DALI, 0 10V, magnetic): ignition, extinction, dimming (to adjust light levels as needed, depending on time schedule) Allows control at lighting point or control of a group of lighting points. Gets the operating status of each lamp / ballast (instantaneous measurement of voltage, current, power factor, power consumption) and sends alarm in case of failure Advantages : Dimming version on magnetic ballast : patented system Positive security : lighting on ensured in case of no communication at powering Configuration of node according to type of lamp and ballast Control of luminary dimming by percentage from 0 to 100 % Dimming orders are applied gradually according a configurable slope (except 0% and 100 % orders which give respectively ignition or extinction of luminary with no wait) => magnetic version Instantaneous measurement of voltage, current, power factor and power consumption Calculation and recording of power consumption and time of ignition SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 2/7
RANGE DESCRIPTION SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 3/7
SL42 2T 1 monitored output (U, I, power factor) ON/OFF for magnetic or electronic ballast (3A Max) SL42 FD 1T* 1 monitored output (U, I, power factor) dimming for magnetic ballasts (250W maxi) SL42 ED 1T 1 monitored output (U, I, power factor) dimming for electronic 1 10V ballasts (3A Max) SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 4/7
SL42 EDA 1T** 1 monitored output (U, I, power factor) 1 dimming output for 2 DALI ballasts (3A Max) SL42 EDA 1 monitored output (U, I, power factor) 1 dimming output for 2 DALI ballasts (3A Max) C Option : measure on auxiliary output * for magnetic version : capacitor must be upstream the ballast ** ballast must be addressed (address 1 or 2 by default) in order to be able to ask and send back its status one controller can control 2 DALI ballasts SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 5/7
MECHANICAL SPECIFICATIONS MATERIAL ABS V0 / PMMA COLOR Charcoal grey MECHANICAL IP42 PROTECTION DIMENSIONS 337.2 x 75 x 48.4 mm WEIGHT 540 gr CONNECTIONS AND INSTALLATION CONNECTORS 9 pins unpluggable (5.08mm max) version SL42 FD 1T 7 pins unpluggable (5.08mm max) versions SL42 ED 1T, SL42 2T and SL42 EDA 1T + 2 pins unpluggable (5.08mm max) versions SL42 ED 1T and SL42 EDA 1T Cables of section0.2 to 3mm² max single stranded, 2.5mm² multi stranded ELECTRICAL SPECIFICATIONS POWERING 230 VAC +10% 15% / 50 à 60 Hz INSTALLATION In the luminary pole Fixation by 1 ou 2 screw (not included) or placed with provided side bracked OUTPUT FEEDBACKS MEASURES ON AUXILIARY (OPTION C) 3A Max U, I Power factor Failures Ignition time Energy consumption I on auxiliary Failures on auxiliary ENVIRONMENT STORAGE TEMPERATURE 25 C to + 75 C USE TEMPERATURE 25 C to + 60 C HUMIDITY 95 % STANDARDSS DIRECTIVE 2006/95/EC «LOW TENSION» CPL SPECIFICATIONS COMMUNICATION CPL(PL3120) CENELEC EN50065 1 (4800 bauds) DIRECTIVE 2004/108/EC «ELECTROMAGNETIC COMPATIBILITY» DIRECTIVE 2002/95/EC «ROHS DIRECTIVE» PROPAGATION CONNECTION Ability to repeat the signal from pole to pole Management of loss of signal Possibility to connect via internet at the segment controller (i.lon Echelon) WARRANTY 5 YEARS WARRANTY (SEE GTS FOR CONDITIONS) LON NETWORK ISO/IEC 14908 LON node based on LonTalk Protocol SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 6/7
ACCESSORIES TL CS ilon Segment controller Single phase segment controller, preconfigured with the lighting application and the remote management software Streetlight.Vision to configure and manage the controller. TL M GPRS GPRS modem pack (Modem+power+antenna). Connection with Ilon via RS232. Automatic configuration Via Ilon (Modem approved by Echelon) TL C Tree phase electricity meter Electricity meter (Class 1) connected and supervised via a Modbus link supervised with segment controller (TL CS). Measure current, voltage, power, power factor. Meter comes with 3 toroids (50A) for measurement of intensity on the 3 phases. SL TP Remote controller Remote controller for Citylone controllers configuration and adressing (consult us for more information) SL42 Lighting controller Citylone, 19 Route du Pont d Arthaud 69510 MESSIMY FRANCE, www.citylone.com 7/7