ETHYL GLUCURONIDE DETERMINATION IN HAIR AS AN INDICATOR OF CHRONIC ALCOHOL ABUSE: A FULLY VALIDATED METHOD BY GC-EI-MS/MS

Similar documents
Jennifer L. Simeone and Paul D. Rainville Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S INT RO DU C T ION

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Screening and quantitative determination of drugs in diluted urine by UPLC-MS-MS

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

Opiates in Urine by SAMHSA GC/MS

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Hair Drug & Alcohol Testing FAQs

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

Quantitation of ethyl glucuronide in serum & urine by gas chromatography - mass spectrometry

How To Test For Contamination In Large Volume Water

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Analysis of Organophosphorus Pesticides in Milk Using SPME and GC-MS/MS. No. GCMS No. SSI-GCMS Shilpi Chopra, Ph.D.

Signal, Noise, and Detection Limits in Mass Spectrometry

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Overview. Purpose. Methods. Results

Pesticide Analysis by Mass Spectrometry

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Fractional Distillation and Gas Chromatography

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Analytical Test Method Validation Report Template

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

The Science of Hair Testing Summary of Literature Review. Presented by SAMHSA s Division of Workplace Programs

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Chemical analysis service, Turner s Green Technology Group

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

One Source Toxicology Laboratory, 1213 Genoa Red Bluff, Pasadena, Texas 77504

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

A commitment to quality and continuous improvement

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Enhancing GCMS analysis of trace compounds using a new dynamic baseline compensation algorithm to reduce background interference

Ethyl Glucuronide. Where is the Drug? Detection Windows. Urine. Blood. Absorption and Distribution. Metabolism. Excretion

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Extraction, Derivatization and Ultra-Sensitive GC/Triple Quadrupole Analysis of Estrone and Estradiol in Human Serum

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

MASS SPECTROMETRIC IDENTIFICATION OF SOME SULPHUR CONTAINING PHENALKYLAMINE DESIGNER DRUGS *

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

Ethyl glucuronide in hair and fingernails as a long-term alcohol biomarker

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

A practical and novel standard addition strategy to screen. pharmacodynamic components in traditional Chinese medicine using

Fernando González-Illán*, Geovannie Ojeda-Torres, Liz M. Díaz-Vázquez*, and Osvaldo Rosario

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Guidance for Industry

Optimizing the Post-implementation Monitoring of a LC-MS/MS Method

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

1.2 This TAP is applicable to concrete, charcoal, coral, debris, wipes and soil.

Analysis of Liquid Samples on the Agilent GC-MS

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Transcription:

FORENSICS AND TOXICOLOGY ANALYSIS ETHYL GLUCURONIDE DETERMINATION IN HAIR AS AN INDICATOR OF CHRONIC ALCOHOL ABUSE: A FULLY VALIDATED METHOD BY GC-EI-MS/MS Solutions for Your Analytical Business Markets and Applications Programs Abstract Market Forensics and Toxicology Author(s) Jennifer P. Pascali 1, Franco Tagliaro 2 1 DTOLabs, Analytical Excellence Centre, authorized Agilent Technologies Partner Lab, Resana (TV), Italy. 2 Department of Public Health and Community Medicine, Unit of Forensic Medicine, University of Verona, Italy. Hair analysis is a powerful tool for the detection of chronic or past drug ingestion and in recent years it has also been exploited for chronic alcohol abuse. Ethyl glucuronide (EtG) determination in hair has been increasingly employed for diagnosing chronic excessive drinking in both clinical and forensic areas. This work describes a simple fully validated method for the determination of EtG in hair using an Agilent 7890B gas chromatograph coupled to an Agilent 7000C triple quadrupole mass spectrometer detector with an electron impact ion source (GC-EI-MS/MS). N-Methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) was used as the derivatizing agent and dimethylformamide (DMF) as the solvent enhancer. Sample decontamination and treatment were performed according to Hastedt et al. (2012). Linearity of the assay was tested between 2.5 100 pg/mg. The sensitivity of the method, expressed as limit of quantitation (LOQ), was 2.5 pg/mg. The method has been applied to a number of real samples, with analytical results in the range of < LOQ to 39 pg/mg.

Introduction Alcohol is the most widely consumed psychoactive substance and is becoming a problematic addiction issue in millions of people worldwide. In fact, unhealthy alcohol use can be either a primary or a secondary cause of liver disease and besides medical complications its abuse can be responsible for severe social problems. From a forensic point of view, it is of extreme importance to monitor alcohol abstinence in patients undergoing alcohol withdrawal treatment when a legal case is proceeding. Laboratory testing traditionally based diagnosis on the assessment of biomarkers such as mean corpuscular volume (MCV), carbohydrate deficient transferrin (CDT) and liver enzymes (gamma-glutamyl tranferase, aspartate aminotransferase and alanine aminotransferase). In the last few years, increased attention has been paid to ethyl glucuronide (EtG), a new specific alcohol intake marker. It is a direct metabolite in the nonoxidative breakdown of ethanol, accounting for less than 0.1% of total ethanol elimination. In literature, several methods have been published for the determination of EtG in hair for the detection of chronic or past alcohol ingestion, exploiting both liquid chromatography and gas chromatography coupled to mass detection. Due to its high polarity, EtG is incorporated into hair only in very small amounts. Accordingly to the new guidelines of the Society of Hair Testing, EtG cut off levels in hair are recommended at 30 pg/mg to distinguish between moderate and heavy alcohol consumption, whereas a 7 pg/mg cut off level is sufficient to pass the medical assessment in the context of driving ability when alcohol abstinence is required [1,2,3,7]. In view of this, among the published methods, necessary sensitivity has only been achieved when triple quadrupole systems have been used or when complex matrix pre-treatments have been employed. Furthermore, some of them lack the requirements for method validation, necessary for endorsement in the field of forensic science. This paper describes a simple fully validated method for the determination of EtG in hair using a gas chromatograph coupled to a triple quadrupole mass spectrometer detector with an electron impact ion source (GC-EI-MS/MS). N-Methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA) was used as the derivatizing agent and dimethylformamide (DMF) as the solvent enhancer. Sample decontamination and treatment were performed according to Hastedt et al.[4]. The sensitivity achieved by this method, expressed as Limit of Quantitation (LOQ), was 2.5 pg/mg. This is comparable to LC-MS/MS published procedures, allowing this method to also be applied to social drinking monitoring. 2

Experimental Materials EtG and the internal standard EtG-D5 were purchased from Medichem (Stuttgard, Gemany). Methanol, dichloromethane and DMF were from Carlo Erba, Milan, Italy. MSTFA was purchased from Sigma-Aldrich (Milan, Italy). Instrumentation GC MS Autosampler Chromatographic Conditions 7890B 7000C 120 CTC Pal System Column: HP-5 column (12 m x 0.200 mm x 0.33 µm) Injection Volume 1 µl, Splitless Injection Port Temperature 250 C Source Temperature 230 C Initial Column Temperature 100 C for 1 minute Rate 1 30 C/min to 200 C Rate 2 15 C/min to 290 C for 5 minutes Aux Temperature 290 C Sample treatment Hair samples were divided into 1-3 cm segments depending on the total length of the hair. The hair samples were then washed twice with 5 ml of dichloromethane for 10 minutes and twice with 5 ml of methanol for 10 minutes. The hair samples were then dried at room temperature and cut into small pieces (2-5 mm). Around 45-55 mg of each hair sample was weighted and transferred into a glass tube. 500 µl of deionized water and EtG-D5 (to a final concentration of 10 pg/mg) were added before centrifugation (3000 rpm for 10 minutes). Samples were incubated overnight at 60 C and ultrasonicated for 10 minutes. The supernatant was taken to dryness under a gentle stream of air at 60 C for 80 minutes. Samples were reconstituted in 40 µl MSTFA and 10 µl DMF, and incubated for 40 minutes at 60 C. One microliter was injected onto the GC-EI-MS/MS. Software MassHunter acquisition, qualitative, quantitative MS/MS MRM Transitions EtG 261 143 @ 10; 261 73 @ 20 EtG-D5 266 143 @ 20

Results and Discussion Validation of the method The validation was carried out according to the international forensic guidelines [5]. The method was validated for selectivity, linearity and sensitivity, precision and accuracy. All calculations were performed using the MassHunter software. Selectivity Seven different hair samples (different colours and hairdresser s treatments) of strict teetotallers were analysed with and without internal standard (IS) in order to determine any endogenous interferent. All tested samples showed no interferent peak at the retention time of the analyte and IS. Linearity and sensitivity The calibration was evaluated by analysing five replicates of spiked hair samples at 2.5, 5, 10, 25, 30, 50 and 100 pg/ mg. An extracted ion chromatogram of a spiked hair sample at 30 pg/mg is shown in figure 1. The peak area ratio of EtG/EtG-D5 was plotted against the relative concentration of EtG/EtG-D5. The seven point calibration curve, determined by the least squares regression method, was linear over the range with an equation of y= 1.315x + 0.131, R square 0.9979 [figure 2]. The LOQ, defined as the lowest concentration with an accuracy RSD < 20 %, was 2.5 pg/mg. The limit of detection (LOD), defined as signal to noise ratio equal to 5, was 1.3 pg/mg. Figure 1. EIC chromatogram of EtG spiked hair sample at 30 pg/mg. Figure 2. Calibration curve of spiked hair samples, 7 levels, 5 repetitions each [x: concentration EtG/concentration EtG-D5, ng/ml; y: area EtG/area EtG-D5]. 4

Precision and accuracy Accuracy and precision of the method were assessed by analysing quality control (QC) samples at concentrations of 2.5 (LOQ), 10, 30 and 100 pg/mg. Five replicates of each standard were analysed on five nonconsecutive days. The intra- and inter-day precision fitted the requirements of the forensic guidelines and the RSDs were always below 10% in QC 10, 30 and 100 pg/mg and below 20% for the LOQ. Accuracy, calculated as bias in the difference between expected concentration and measured concentration, was below 10 %. Precision and accuracy data are summarised in Table 1. Parameter QC 2.5 pg/mg QC 10 pg/mg QC 30 pg/mg QC 100 pg/mg Intra-day mean 2.7 10.3 28.0 100.9 SD 0.07 0.05 0.50 2.90 RSD, % 2.5 0.5 1.7 3.0 Absolute bias + 0.2 + 0.3-2 + 1 Bias, % + 7 + 0.1-6 + 1 Inter-day mean 2.6 10.2 29.7 102 SD 0.40 0.83 2.00 3.50 RSD, % 15.0 8.0 6.8 3.4 Absolute bias + 0.1 + 0.2-0.03 + 2.0 Bias, % + 3.8 + 2.0-0.1 + 2.0 Table 1. Summary of intra-day and inter-day QC sample data. Stability For estimating the stability of the processed sample, three QC levels at 30, 50 and 100 pg/mg were prepared and analysed on day 0 and day 4. Samples prepared on day 0 and analysed on day 4 were compared in terms of absolute peak areas and calculated concentration with samples analysed soon after preparation. During the experiment, the samples were stored on the GC autosampler at room temperature. Instability of the process would have been indicated by a decrease of peak areas of more than 15% according to Albermann et al. [6]. The calculated decrease of measured EtG was around 42 %, well above the fixed 15%, as could be expected when a derivatizing step is involved. Application of the method The applicability of this method has been tested on a few authentic hair samples (n=7) from subjects with a well-known drinking behaviour. The EtG concentrations varied between < LOQ and 7.5 pg/mg for moderate drinkers (n=4, CDT concentrations < 1.8 %). No EtG was determined in teetotallers hair samples (n=2, CDT concentrations < 1.0 %), who declared no use of any alcohol containing food or medicaments nor use of any hair cosmetics potentially containing EtG. A single wellknown heavy drinker (reported daily alcohol intake: ten units, whose habit was also proved by a CDT value of 6.0 %) showed an EtG concentration of 39 pg/mg, above the cut-off of 30 pg/mg suggested by the Society of Hair Testing. The results are summarized in Table 2. Sample Hair (mg) EtG concentration (pg/mg) Abstinent 1 76 <LOQ Abstinent 2 59 <LOQ Social drinker 1 49 4 Social drinker 2 50 <LOQ Social drinker 3 53 7.5 Social drinker 4 20 <LOQ Heavy drinker 38 39.0 Table 2. Summary of EtG concentrations in real hair samples. 5

Interfering peaks were not observed, but in one case the relative peak area of the transition 261 73 was badly influenced by the matrix, giving some complication in the quantitation process, although the target ion was not affected. The MRM chromatogram of a real sample is shown in Figure 3. Figure 3. MRM Chromatogram of a real hair sample (Transitions 261 143, 261 73 for EtG, 266 143 for IS); EtG calculated concentration 7.5 pg/mg. Conclusion Hair analysis for EtG has been increasingly employed for diagnosing chronic excessive drinking or for monitoring abstinence in both clinical and forensic fields. From an analytical point of view, the literature has traditionally been focused on methods based on liquid chromatography coupled to mass spectrometry mainly because of the fast sample treatment procedure and very low detection limits. However, due to the introduction of more sensitive gas chromatographytriple quadrupole instrumentation, more attention has recently been paid to gas chromatography methods. This paper demonstrates that EtG can be successfully determined in hair by GC-EI-MS/MS. The method has been fully validated and is linear over the range of 2.5 100 pg/mg, with a LOQ of 2.5 pg/mg. 6

References 1. Marques PR. Levels and types of alcohol biomarkers in DUI and clinic samples for estimating workplace alcohol problems, Drug Test Anal., 2, 4, 2012. 2. Boscolo-Berto R, Viel G, Montisci M, Terranova C, Favretto D, Ferrara SD, Ethyl glucuronide concentration in hair for detecting heavy drinking and/or abstinence: a meta-analysis, Int J Legal Med., 3, 127, 2013. 3. Morini L, Colucci M, Ruberto MG, Groppi A, Determination of ethyl glucuronide in nails by liquid chromatography tandem mass spectrometry as a potential new biomarker for chronic alcohol abuse and binge drinking behaviour, Anal Bioanal Chem., 5, 402, 2012. 4. Hastedt M, Herre S, Pragst F, Rothe M, Hartwig S, Workplace alcohol testing program by combined use of ethyl glucuronide and fatty acid ethyl esters in hair, Alcohol Alcohol, 2, 47, 2012. 5. Peters FT, Drummer OH, Musshoff F, Validation of new methods, Forensic Sci Int, 2-3, 165, 2007. 6. Albermann ME, Musshoff F, Aengenheister L, Madea B, Investigations on the influence of different grinding procedures on measured ethyl glucuronide concentrations in hair determined with an optimized and validated LC-MS/MS method, Anal Bioanal Chem, 3, 403, 2012. 7. Dufaux B, Agius R, Nadulski T, Kahl HG, Comparison of urine and hair testing for drugs of abuse in the control of abstinence in driver s license regranting, Drug Test Anal, 6, 4, 2012. 7

This publication are subject to change without notice. Solutions for your analytical business Markets & Applications Programs www.agilent.com/chem/solutions_app Agilent Technologies, Inc. 2013 Published in Germany, December 18, 2013 5991-3713EN