BG - General purpose filter/regulator Excelon Plus Modular System > Port size: 1/4... 3/ (ISO G / PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > or 40 micron particle and high efficiency water removal (> 9%) > Double safety lock bowl > Push to lock adjusting knob with built in tamper resistant feature > Metal bowl with prismatic liquid level indicator lens > Light weight Polycarbonate bowl with guard > Easy to read flush mounted integrated pressure gauge > Air purity classes in accordance to ISO73-1:010: 7::4 (40μm) 6::4 (μm) Technical features Medium: Compressed air only Maximum supply pressure: Polycarbonate bowl: 10 bar (14 psi) Metal bowl: 17 bar (46 psi) Outlet pressure ranges: 0.3... 10 bar (4... 14 psi), 0.3... 4 bar (4... psi) optional, 0.7... 17 bar (... 46 psi) optional Filter element: μm & 40 μm Port size: G1/4, G3/,1/4 PTF, 3/ PTF Gauge: Integrated as standard Gauge port 1/ as option Flow: dm³/s at port size 1/4, dm³/s at port size 3/, inlet pressure 10 bar (14 psi), 6.3 bar (91 psi) set pressure and a Δp: 1 bar (14. psi) droop from set. Diaphragm Type: Relieving Drain: Manual or automatic Automatic drain operating conditions (float operated): Bowl pressure required to close drain: > 0.3 bar ( psi) Bowl pressure required to open drain: 0. bar (.9 psi) Minimum air flow required to close drain: 1 dm³/s. Ambient/Media temperature: Polycarbonate bowl: -10... +60ºC (+14... +140ºF) Metal bowl: -0... +6ºC (-4... +149ºF) Air supply must be dry enough to avoid ice formation at temperatures below + C (+3 F). Atex: Filter/regulators B are in conformity with Atex 014/34/EU II GD Ex h IIC T6 Gb EX h IIIC T C Db Materials: Body: Die cast aluminum Body covers: ABS Bonnet: Acetal/ Aluminum Valve: PP Transparent Bowl : Polycarbonate with Polypropylene Guard. Metal Bowl: Die cast Zinc with PA liquid level indicator lens Filter element: sintered PP Bowl O - ring: Chloroprene Elastomers: NBR Technical data BG standard models Symbol Port Drain Pressure range (bar) Filter element (µm) *1) All models shown here are supplied with integrated gauge applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact IMI Norgren Bowl Weight (kg) Model *1) G1/4 Auto 0,3... 10 40 Guarded polycarbonate 0, BG-GK-AP3-RMG G3/ Auto 0,3... 10 40 Guarded polycarbonate 0, BG-3GK-AP3-RMG G1/4 Auto 0,3... 10 40 Metal with level indicator 0,0 BG-GK-AD3-RMG G3/ Auto 0,3... 10 40 Metal with level indicator 0,0 BG-3GK-AD3-RMG G1/4 Manual 0,3... 10 40 Guarded polycarbonate 0, BG-GK-QP3-RMG G3/ Manual 0,3... 10 40 Guarded polycarbonate 0, BG-3GK-QP3-RMG G1/4 Manual 0,3... 10 40 Metal with level indicator 0,0 BG-GK-QD3-RMG G3/ Manual 0,3... 10 40 Metal with level indicator 0,0 BG-3GK-QD3-RMG en.10.30.01
Option selector *1) BG H H H H H H R H H Port size 1/4 3/ 3 Thread form PTF ISO G (standard) Adjustment Knob (standard) T-bar Drain Manual (standard) Auto drain (standard) Bowl Metal with liquid indicator Transparent with guard (standard) A G K T*) Q A D P *1) All models shown here are applicable for flow direction left to right. With flow direction right to left please use the online configurator www.imi-precision.com/air-preparation-configurator or contact IMI Norgren *) Units with 46 psi (17 bar) outlet pressure range are available only with the T-bar adjustment; therefore substitute T at the 7th position and S at the 9th position. T-bar handle only available with 17 bar option. Gauge With integrated gauge (standard) Without integrated gauge but with gauge port 1/ Pressure range *3) *3) Outlet pressure can be adjusted to pressures in excess of, and less than, those specified. Do not use these units to control pressures outside of the specified ranges. G N 0.3 to 4 bar F 0.3 to 10 bar (standard) M 0.7 to 17 bar S*) Element 40 μm (standard) 3 μm 1 Flow characteristics Inlet pressure: 10 bar (14 psi) Range: 0.3...10 bar (4...14 psi) Port size: 1/4, µm element Inlet pressure: 10 bar (14 psi) Range: 0.3...10 bar (4...14 psi) Port size: 3/, µm element.0 7.0.0 7.0 Outlet pressure (bar) 6.0.0 4.0 3.0.0 Outlet pressure (bar) 6.0.0 4.0 3.0.0 1.0 1.0 0 0 10 0 40 0 0 10 0 40 Air flow (dm 3 /s) Air flow (dm 3 /s) Inlet pressure: 10 bar (14 psi) Range: 0.3...10 bar (4...14 psi) Port size: 1/4, 40 µm element Inlet pressure: 10 bar (14 psi) Range: 0.3...10 bar (4...14 psi) Port size: 3/, 40 µm element.0 7.0.0 7.0 Outlet pressure (bar) 6.0.0 4.0 3.0.0 Outlet pressure (bar) 6.0.0 4.0 3.0.0 1.0 1.0 0 0 10 0 40 Air flow (dm 3 /s) 0 0 10 0 40 Air flow (dm 3 /s) en.10.30.0
Accessories Quikclamp Quikclamp with bracket assembled Neck mounting bracket and panel nut Panel mounting nut Mounting bracket Page 6 Page 6 0014-1KIT 0014-KIT 006-1KIT 004-9KIT 004-0KIT Integrated gauge 10 bar gauge Integrated gauge 0 bar gauge Integrated gauge 4 bar gauge Gauge adaptor kit 1/ PTF Gauge adaptor kit R 1/ 0073-01KIT 0073-0KIT 0073-03KIT 0100-01KIT 0100-0KIT Pressure sensing block 1/4 PTF Pressure sensing block G1/4 Porting block 3/ PTF Porting block G3/ Pressure switch interface block (1D pressure switch) G1/4 Page 0016-0KIT 0016-1KIT 00-0KIT 00-3KIT 009000000000 Pressure switch 1D (0,... bar) *1 Digital pressure switch 1D (-1... 10 bar) * Connector 4- Series *3 Padlock Lockout device Page Page 010 06010 4417-01 4a00-01KIT 400-0KIT *1) Flanged version. For other pressure ranges, please see data sheet.11.001 *) For other pressure ranges, please see data sheet.11. *3) For connection please use Quikclamp series and Hybrid-Quikclamp 4 series Port Adaptors Gauges (For regulators with gauge port instead of integrated port ) Center back connection, white face (for full technical specification see datasheet.900.900) Page 1/4 PTF 001-0KIT 3/ PTF 001-03KIT G1/4 001-0KIT G3/ 001-09KIT Pressure range (bar)*3) (MPa) (psi) ø Thread size Model 0... 6 0... 0,6 0... 4 40 mm R1/ 1-01- 0... 10 0... 1 0... 14 40 mm R1/ 1-01-99 0... 0..., 0... 36 40 mm R1/ 1-01-90 *3) primary scale en.10.30.03
Maintenance/Service Filter cartridge micron Filter cartridge 40 micron Auto drain kit with metal Nut - Imperial Auto drain kit with metal Nut - Metric R / B Elastomer Kit 00-0KIT 00-1KIT 6000-61KIT 6000-60KIT FRLB-KIT Spare parts Filter Bowl (Guarded Poly bowl with auto drain 6 mm PIF) Filter Bowl (Guarded Poly bowl with manual drain) Filter Bowl (Metal with S/ Glass & auto drain, 6 mm PIF) Filter Bowl (Metal with S/ Glass & manual drain) 00-1KIT 00-0KIT 0003-1KIT 0003-0KIT Filter Bowl (Guarded Poly bowl with auto drain, 1/4 PIF) Filter Bowl (Metal with S/ Glass & auto drain, 1/4 PIF) 00-3KIT 0003-6KIT en.10.30.04
Dimensions Dimensions in mm Projection/First angle 1/4 Turn Manual Drain Automatic Drain T-bar adjustment 106 77 7 11 73 7 11 36 1 36 36 1 17 # 17 # 160 1 6 6 6 46, 46, 46, # Minimum clearance for bowl removal 1 Main ports 1/4, 3/ (ISO G/PTF) Gauge port Rc 1/ for ISO G and 1/ PTF for PTF main ports en.10.30.0
7 Accessories Neck mounting bracket Dimensions in mm Projection/First angle Quikclamp with wall bracket 1 7 1 9 44 6 4 49 7 43 101 39 4 14 Quikclamp 3 1 47 44 14 43 9 39 6 Panel mounting nut R R1 Ø 4 1 Universal Mounting bracket 49 34 3 6 3 34 1 49 en.10.30.06
Pressure sensing block Full flow porting block Dimensions in mm Projection/First angle 0 4 4 19 7 36 Porting block for 1D pressure switch 1D Pressure switch 1 A/C 4 40 3 G 1/4 44 40 3 7 1D Porting block and 1D assembled Pipe adaptor 9 16 9 16 9 9 40 3 40 G 1/4 40 3 44 Connector 4- Series 44 7 3. 1 3. 9.6 G 1/ G 1/ 7 en.10.30.07 6
1D Pressure switch - digital Dimensions in mm Projection/First angle 1 G 1/ 6 7 0 3 4 1 Switch OUT 1, green LED Switch OUT, red LED 3 Dustproof protector 4 Connector M1 x 1 Inlet port 6 Alternative inlet port G1/ plugged 7 Thread for mounting screw Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under»technical features/ data«. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult Norgren Ltd. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. en.10.30.0