LCD Readout Digital Pressure Switch

Similar documents
3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3 Port Solenoid Valve

Vacuum Module: Series ZX Vacuum Ejector System/External Vacuum Supply System

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Cross-beam scanning system to detect slim objects. 100 mm in

Adjustment functions for both span and shift have been incorporated

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

W150: Miniature photoelectric switch series with completely integrated electronics

U-shaped Micro Photoelectric Sensor

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

REGTRONIC OPERATING INSTRUCTIONS

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Digital Flow Switch for Water 3 -color/2-screen display

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Electronic Pressure Switch EDS 300

Duct Humidity Transmitter

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

Liquid Leakage Sensor Amplifier

PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

2 Window comparator mode. Hysteresis Hysteresis

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

How To Read A Pipe From A Sensor

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Givare NC-SRS 280 och 880

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PTU Series Ultrahigh-Purity Pressure Transducers

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Absolute Rotary Encoder E6CP

T0118 T2118 T3118. Instruction Manual

Emergency lighting units EM powerled

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

MINI MCR-SL-R-UI(-SP)

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Pressure transmitter For general industrial applications Model A-10

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Multifunction Digital Timer

Digital display DA 48

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

Electro-Pneumatic Bus Door Control Mechanism

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Series 7500 Torque Sensor

Proportional pressure regulators VPPE

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Contents. Document information

T7560A,B,C Digital Wall Module

Model 201 Wiegand Touchpad Reader Installation Guide

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Color Mark Sensor with Red or Green LED E3S-VS

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

4.3-inch Back-Up Camera

technical data (according to IEC )

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Electronic Pressure Switch EDS 3000

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Fiber-Optic Photoelectric Sensor

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DUBOX TM LOOSE PIECE HAND TOOL

Proximity Switches RS (Reed Switch)

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Preset Counter signo 721

Model Number Structure

I STAR COMPUTER CO., LTD

Oil - kerosene burners

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Smart Sensing Solutions Since 1954

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Radiant Temperature Sensor TY7321

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Transcription:

LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series ZX E30 E40 E10 E70 E80 Built-in failure prediction output function When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs. Two independent outputs Allows the calibration of two different setpoints e.g. change of vacuum pad size requiring different setpoints, two different supply pressures requiring different pressure confirmation points. Calibration data The calibration data is stored in an EEPROM. The EEPROM is rated to keep its memory for 100,000 hours (approx. 11 years) without having power supplied. Suction filter comes as standard Self-diagnostic function Excessive current Excessive pressure Data error SMC LCD: Error display Indication lights: LED (Red) RE 839

LCD Readout Digital Pressure Switch Series ZSE3/E3 RoHS How to Order Operating pressure range Nil L 0 to 0.98 MPa 0 to 98 Piping specifications 01 Single mounting R 1 /8 T1 Single mounting NPTF 1 /8 Note 1) M5 x 0.8 female threaded. Note 1) Note 1) Output specifications NPN open collector 2 outputs 21 without analog output 22 NPN open collector 2 outputs with analog output (1 to 5 V) Positive pressure E3 ZSE3 Suffix Nil None D For replacement with ZX series Note 3) Compliant with piping specifications OX and OXY only. Wiring specifications Nil Grommet type (Lead wire: 0.6 m) L Grommet type (Lead wire: 3 m) C Connector type (Lead wire: 0.6 m) CL Connector type (Lead wire: 3 m) CN Without connector Analog output is only available in a grommet type. Piping specifications 01 Single mounting R 1 Note 2) /8 T1 Single mounting NPTF 1 Note 2) /8 0X With suction filter M5 x 0.8 0XY With suction filter M6 x 1 (Option) Note 2) Single mounting type: M5 x 0.8 female threaded. Output specifications 21 22 23 24 NPN open collector 2 outputs without analog output NPN open collector 2 outputs with analog output (1 to 5 V) NPN open collector 1 output Failure predict function without analog output NPN open collector 1 output Failure predict function with analog output (1 to 5 V) With Connector/How to Order Without lead wire (Connector 1 pc., Socket 4 pcs.) ZS-20-A With lead wire ZS-20-5A- Note 3) When ordering switch with 5 m long lead wire, indicate both part numbers. Ex.) ZSE3-01-21CN 1 pc. ZS-20-5A-50 1 pc. 840 Nil 0.6 m 30 3 m 50 5 m Replacement Element (Filter) Part Number (Refer to page 843) Filter vessel assembly (Filter vessel, Filter element) ZX1-FK-PC Filter element ZX1-FE Filter gasket ZX1-FG

LCD Readout Digital Pressure Switch Series ZSE3/E3 Specifications For details about the Pressure Switch Precautions, refer to pages 763 and 764. For details about the Specific Product Precautions, refer to the Operation Manual at SMC website. Model ZSE3 Positive pressure 100 E3L Positive pressure 1 MPa E3 Operating pressure range Max. operating pressure Min. display unit MPa Indicator light (2) Frequency response (3) Hysteresis mode Hysteresis Window comparator mode Fluid Temperature characteristics Repeatability Power supply voltage Switch output Current consumption Error display Pressure indication Self-diagnostic function Operating temperature range Noise resistance Withstand voltage Insulation resistance Connector type Lead wire Weight Port size Enclosure Standard Grommet type 0 to 101 1 0 to 98 0 to 0.98 MPa 200 (1) 1 MPa 1 0.01 N: When Green LED (OT1) or Red (OT2) turns on 200 Hz Adjustable (Variable from 0) Fixed (3 digits) Air, Non-corrosive gases ±3% F.S. or less ±1% F.S. or less 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) NPN open collector 30 V 80 ma or less 25 ma or less Red light blinks. Display the error code on LCD. 3 1 /2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60 C (No dewing) 1000 Vp-p, Pulse width 1 µs, Rise time 1 ns 1000 VAC in 50/60 Hz for 1 minute between terminals and housing 2 MΩ or more (500 VDC measured via megohmmeter) betweeen terminals and housing Heat-resistant vinyl electric wire, 4-wire, Conductor area: 0.31 mm 2, Insulator O.D.: 1.55 mm Oilproof heavy-duty vinyl cable -21, -23: 4 cores, ø3.5, Conductor area: 0.14 mm 2, Insulator O.D.: 1.0 mm -22, -24: 5 cores, ø3.5, Conductor area: 0.15 mm 2, Insulator O.D.: 1.0 mm 40 g (including 0.6 m-long lead wire) R 1 /8, M5 x 0.8, NPTF 1 /8, M5 x 0.8 R ZX ejector mounted type: M5 x 0.8 1 /8, M5 x 0.8 NPTF 1 /8, M5 x 0.8 IP40 CE, RoHS Note 1) Instant pressure supply of 0.5 MPa has no influence on the switch. Note 2) ZSE3- - 2324 : Failure predictive output is Red. Note 3) Window comparator mode: The hysteresis is 3 digits, so separate P1 from P2 by 7 digits or more and set them. 1 digit is the minimum pressure display unit. (See the table above.) E30 E40 E10 E70 E80 841 A

Series ZSE3/E3 Calibration Procedure Pressure Setting 2 output type 1. Input mode for set point value 2. Input set point value for OT1 (1) 3. Input set point value for OT1 (2) Press the Press the Press the P1: Setting of OT1 P2: Setting of OT1 P3: Setting of OT2 P4: Setting of OT2 (Refer to the Table 1.) 4. Input set point value for OT2 (1) 5. Input set point value for OT2 (2) Press the Press the button to complete the setting. Table 1 Hysteresis mode (P1 P2, P3 P4) ON Output type Hysteresis (Variable from 0) OFF P2 (P4) Pressure Low Low P1 (P3) High High ON OFF P1 (P3) Pressure Low Low P2 (P4) Window comparator mode (P1< P2, P3< P4) Note) Window comparator mode (one for positive pressure is same) Hysteresis is 3 digit, so set P1 and P2 (also P3 and P4) at Hysteresis (Fixed) (Hysteresis = 3 digits fixed) Hysteresis (Fixed) least 7 digit. 1 digit is the minimum setting pressure unit. High High 1 output type with failure prediction function 1. Input mode for set point value 2. Input set point value for OT1 (1) 3. Input set point value for OT1 (2) Press the Press the Press the P1: setting of OT1 P2: setting of OT2 P3: setting of failure prediction pressure EC: Number of failure prediction 4. Calibration of failure predictive pressure 5. Calibration of number of failure prediction occurrences Press the Press the button to complete the setting. Table 2 Failure prediction (Refer to the Table 2.) High P3 Set pressure P1 Set pressure Low P2 Failure prediction counter Normal 1 time 2 times 3 times 842 Occurrence number: 1 to 16 times (0 is not available for prediction.) Failure prediction will register when switches turn OFF without reaching the pressure of (P3) after switch turns ON (over P1). Output of failure detection occurs when failure prediction is counted continuously within certain preset levels. The count of failure prediction is reset when switch turns ON (over P1) and pressure exceeds the failure prediction set pressure (P3). (Example of hysteresis mode.)

LCD Readout Digital Pressure Switch Series ZSE3/E3 Other Functions Peak mode high RE RE RE SMC Peak mode low SMC Reset function SMC To display the high peak pressure (highest degree of vacuum), press the button during normal operation. The LCD displays H. To return back to the normal operation, press the button again. To display the low peak pressure (lowest degree of vacuum), press the button during normal operation. The LCD displays. To return back to the normal operation, press the button again. A RE operation leads to the following results. 1) Reset will cause the following during normal operation: Peak high is cleared. Peak low is cleared. Failure prediction counter is cleared. Failure predictive output is reset. 2) Reset will cause the following when an error has occurred: Data set in setting mode will remain stored and will return to the same state as when the power is applied. (All calibration data has retained.) In the case of data error, reset the setup mode and then switch will assume normal operation. (All calibration data has retained.) Note) Reset Function does not work during setup mode. Internal Circuits and Wiring Examples -21 NPN (2 outputs) Main circuit LED Green LED Red Brown DC (+) Black OT1 White OT2 Blue DC ( ) -23 NPN (1 output) + Failure predictive output Main circuit LED Green LED Red Brown DC (+) Black OT1 White Failure predictive output + + 12 to 24 VDC 12 to 24 VDC Error Correction Take the following corrective solutions when errors occur. Display Description Solution LED Green LED Red LED Green LED Red Set data was changed by accident, reason unknown. OT1 is short-circuited. Overcurrent is being applied to the load. OT 2 is short-circuited. Overcurrent is being applied to the load. Pressure exceeding 0.5 MPa is being applied. (The pressure over rated pressure is being applied in case of positive pressure.) When performing zero clear, compared with the atmospheric pressure, pressure of more than ±0.07 MPa for 1 MPa and ±7 for vacuum is being applied. Brown DC (+) Gray Analog output Black OT1 White OT2 Blue DC ( ) Brown DC (+) Gray Analog output Black OT1 Failure predictive White output Perform the RE operation, and reset all data again. Turn off the power and replace the load connected with OT1 (Black wire). Turn off the power and replace the load connected with OT2 (White wire). Reset the supply pressure less than 0.5 MPa. (Reduce the supply pressure to below rated pressure in case of rated voltage.) Apply atmospheric pressure and then reset the switch. -22 NPN (2 outputs) + Analog voltage output Main circuit + + 12 to 24 VDC -24 NPN (1 output) + Failure predictive output+analog voltage output Main circuit 12 to 24 VDC E30 E40 E10 E70 E80 Blue DC ( ) Blue DC ( ) 843 A

LCD Readout Digital Pressure Switch Series ZSE3/E3 How to se Connector 1. Attaching and detaching connectors When assembling the connector to the switch housing, push the connector straight onto the pins until that lever locks into the housing slot. When removing the connector from the switch housing, push the leverdown to unlock it from the slot and then withdraw the connector straight off of the pin. Hook With connector 0.2 to 0.33 mm 2 Max. coating O.D. ø 1.7 mm Socket Part no. DXT170-71-1 Connector DC polarity indicator Lever Pin Slot Housing 2. Crimping of lead wires and socket Strip 3.2 to 3.7 mm of the lead wire end, insert each stripped wire into a socket and crimp contact it using special crimping tool. Be careful that the outer insulation of the lead wires does not interfere with socket contact part. (Crimping tool: DXT170-75-1) 3. Attaching and detaching lead wires with sockets Attaching Push the socket into the square holes of the connector (with +, 1, 2, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires. Detaching To detach a socket from connector, pull out lead wire while pressing the socket's hook with a stick having a thin tip (about. 1 mm). If the socket will be used again, first spread the hook outward. How to Replace Filter Element Replace the filter element when clogging causes deterioration of the adsorption force or slow response time. (Element part number: ZX1-FE) Confirm that the filter gasket is seated in the groove and then reassemble the parts. (Filter gasket part no.: ZX1-FG) Filter case Filter element (ZX1-FE) Filter gasket (ZX1-FG) Gasket groove Filter vessel assembly (Filter vessel + Filter element) ZX1-FK-PC Regarding the filter vessel Caution 1. The vessel is made of polycarbonate. Therefore, do not operate it in an environment that is exposed to chemicals such as thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting oil (alkalinic). 2. Operate it away from direct sunlight. E30 E40 E10 E70 E80 843-1 A

Series ZSE3/E3 Dimensions/Switch Only Grommet type I Z 01 T1 SE3- - 30 30 8.5 3.5 39 10 (3000) 20.5 8.5 3.5 40.5 (3000) 20.5 RE button button DOWN button P button 600 2 x ø3.5 Mounting hole 13 01: R 1/8 T1: NPTF 1/8 M5 x 0.8 Connector type I Z 01 T1 SE3- - C RE button button DOWN button P button 600 2 x ø3.5 Mounting hole 13 01: R 1/8 T1: NPTF 1/8 M5 x 0.8 844

LCD Readout Digital Pressure Switch Series ZSE3/E3 ZSE3-0X - -D Grommet type 7 ZSE3-0X - PV 8 10.3 supply port 0X: M5 x 0.8 0XY: M6 x 1.0 RE button button 600 51.5 (3000) 50.6 DOWN button P button 10 22.6 2 x ø3.3 Mounting hole 20.5 6.5 18 58 supply port 10.2 P 5.8 pad connection port 0X: M5 x 0.8 0XY: M6 x 1.0 # Pneumatic circuit pad connection port E30 E40 E10 E70 E80 Connector type ZSE3-0X - C 7 50.6 20.5 supply port P # pad connection port RE button button DOWN button P button Pneumatic circuit 50 10 600 (3000) PV 8 18 10.2 58 ZSE3-0X - C-D 10.3 supply port 0X: M5 x 0.8 0XY: M6 x 1.0 10 22.6 2 x ø3.3 Mounting hole 6.5 5.8 pad connection port 0X: M5 x 0.8 0XY: M6 x 1.0 845 A