2 Window comparator mode. Hysteresis Hysteresis
|
|
|
- Simon Lawson
- 9 years ago
- Views:
Transcription
1 SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-00. [Category applicable for semiconductor manufacturing: TWW2, Process Equipment] [Applicable standards: UL 61010C-1] [Additional test / evaluation standards as per intended use: UL991, SEMI S2-00] * Passed the UL 991 Environment Test Conforming to EMC Directive UL Recognition (Excluding 5 m cable length type) High accuracy high resolution high speed Clearly visible LED display with 3 1 /2 digits Setting with easy key operation It achieves a 2.5 ms, or less, response time at a high resolution of 1/1,000. It enables highly accurate sensing with its excellent repeatability and temperature characteristics. Bright red LED 7-segment display having 3 1 /2 digits, 10 mm in high. The displayed figures are remarkably noticeable not only in a dark area, but also in a well-lit place. Initialization and threshold value settings are easily done by key operation while seeing the values on the display. Repeatability Within 0.2 % F.S. 1 digit Response time 2.5 ms or less Temperature characteristics Within 1 % F.S. Incorporates minus sign indication Four output modes enable versatile pressure level control 1 Hysteresis mode The common hysteresis of the comparative outputs can be set, as desired, with the set values. 3 Dual output mode Hysteresis Output 1 OFF Output 2 OFF 0 Set Value 1 (P-1) Set Value 2 (P-2) High pressure (Positive pressure type) High vacuum (Vacuum pressure type) The outputs can be put to different use, such as, detection of different kinds of objects, control function, alarm function etc. 2 Window comparator mode Hysteresis Hysteresis Hysteresis Output 1 OFF Output 1 OFF Output 2 OFF Output 2 OFF 0 Set Value 1 (P-1) Set Value 2 (P-2) 0 Set Value 1 (P-1) Set Value 2 (P-2) High pressure (Positive pressure type) High vacuum (Vacuum pressure type) High pressure (Positive pressure type) High vacuum (Vacuum pressure type) The comparative outputs can be turned or OFF by a pressure which is within the pressure range set by Set Value 1 and Set Value 2. 4 Automatic sensitivity setting mode Hysteresis Output 1 OFF Output 2 OFF 0 Set Value 1 (P-1) Set Value 2 (P-2) Set Value 3 (P-3) High pressure (Positive pressure type) High vacuum (Vacuum pressure type) Using actual objects, if the pressure values for OK objects and NG objects are input, then the sensor is automatically set to the optimum pressure value (mid-value). Selection from six pressure units The pressure unit can be selected from six different systems to suit your requirement. The selectable pressure units differ with the sensor type. When the pressure unit is changed, the measured pressure value and the set values are automatically converted. ( ) : Vacuum pressure type : Positive pressure type 792 inhg International System of Units (SI) kpa (Note) kgf/cm 2 mmhg psi bar Note: MPa in case of -22, -42 and -62.
2 APPLICATIS Confirmation of chip component suction The light weight type does not disturb the movement of the suction head, even if it is mounted close to the head. Total weight: 70 g approx. -80 Controlling clamping force The clamping force can be changed to suit the workpiece by controlling the supplied air pressure. -42 Inspecting orientation of glass sheet The orientation of the glass sheet can be recognized by detecting the change in vacuum due to presence / absence of indentation. -80 IC tray IC -80 Vacuum tank Vacuum pump Verifying placement of frame High pressure is attained when the frame is exactly seated. Hence, the pressure change when the frame is exactly placed is detected. -41 Tank Air Frame Seats Detecting tap breakage Two opposed nozzles are supplied air at different pressures. If the tap breaks, the pressure at the lower pressure side nozzle is affected by the air of the higher pressure side nozzle. This change in pressure is detected. Air High pressure Nozzle A -62 Nozzle B -61 Air Low pressure Controlling edge of winding film With bifurcated nozzles placed on both sides of the film, the position of the winding film is recognized as right-shifted (high pressure), OK (middle pressure), or left-shifted (low pressure). -41 Air DP3 Analog voltage output incorporated as a standard Since a linear analog voltage output (1 to 5 V) is incorporated, the sensor is ideally suited for real time monitoring or for remote control in combination with an analog controller (ultra-compact digital panel controller CA2 series, or digital panel controller CA series). Peak hold / bottom hold display The peak value or the bottom value of the varying pressure can be displayed. This function is convenient for finding the pressure variation range or for determining a reference for pressure settings. Analog bar display Pressure changes can also be displayed in an analog fashion using LED bars. Hence, sudden pressure changes can be recognized at a glance. LED bars indicate the pressure level in steps ( of 10 % F.S., regardless of the pressure unit. Analog bar display Digital display ( A Wide Variety of Models Models are selectable according to mounting style, environmental resistance, and manner of use. Standard type / -2 Direct piping Light weight type / -80 Total weight 70 g approx. The sensor can be mounted on the suction head of a chip mounter. European type type type Mounting on a panel kPa IP67 type / -6 Water and dust proof European Flat type / -4 Direct mounting on a wall The series covers worldwide usage with the type, the type and the European type. Each type provides the customary pressure unit, suitable output, and pressure port. Pressure unit The international system of unit (SI) Pa kgf/cm 2 (Positive pressure type) mmhg (Vacuum pressure type) psi (Positive pressure type) inhg (Vacuum pressure type) bar Output NPN and analog voltage NPN and analog voltage Pressure port or M5 NPT 1 /8 or NPTF 1 /8 PNP and G (PF) 1 /8 analog voltage 793
3 ORDER GUIDE Type Appearance Rated pressure range Model No. Pressure port output Vacuum pressure 101 kpa type 0 to kpa - -F -F-P NPTF 1 /8 DP3 Standard Light weight Flat Positive pressure Vacuum pressure Positive pressure 1 MPa type 100 kpa type 101 kpa type 1 MPa type 100 kpa type European European European 0 to kpa 0 to MPa 0 to kpa 0 to kpa 0 to MPa F -21F-P F -22F-P N -40E N -41E N -42E NPTF 1 /8 NPTF 1 /8 M5 NPT 1 /8 G (PF ) 1 /8 NPT 1 /8 G (PF) 1 /8 NPT 1 /8 G (PF) 1 /8 Vacuum pressure 101 kpa type European 0 to kpa N -60E NPT 1 /8 G (PF) 1 /8 IP67 Positive pressure 100 kpa type 1 MPa type European European 0 to kpa 0 to MPa N -61E N -62E NPT 1 /8 G (PF) 1 /8 NPT 1 /8 G (PF) 1 /8 794
4 ORDER GUIDE 5 m ft cable length type 5 m ft cable length type is also available. (Standard: 2 m ft) Type Vacuum pressure 101 kpa type Standard - -F -F-P 5 m ft cable length type --C5 Standard Positive pressure 100 kpa type F -21F-P C5-22-C5 1 MPa type -22F Flat Light weight Vacuum pressure Positive pressure 101 kpa type 100 kpa type -22F-P N -40E N -41E C5-41-C5-42-C5 DP3 1 MPa type -42N Vacuum pressure 101 kpa type -42E N -60E IP67 Positive pressure 100 kpa type N -61E -62 The IP67 type is the standard type with a 5 m ft cable. 1 MPa type -62N -62E Accessories DPX-01 [Pressure port attachment (Standard type only)] DPX-02 [Hexagon-socket-head plug for pressure port (Standard type only)] Pressurer port attachment DPX-01 Hexagon-socket-head plug for pressure port DPX
5 OPTIS Designation Model No. Description Sensor mounting bracket MS-DPX MS-DPX-4 DP3 Sensor mounting bracket (For standard type) Straight bush Panel mounting bracket (For standard type) Front protection cover (For standard type) Digital panel controller (Note) MS-DPX MS-DPX-4 DPX-03 MS-DPX-2 DPX-04 CA2-T2 CA-R2 CA-T2 CA-B2 Mounting bracket for standard type Two M4 (length 6 mm in) pan head screws and two spring [ washers are attached. Back angled mounting bracket for standard type Two M4 (length 6 mm in) pan head screws and two spring [ washers are attached. Changes the pressure port from [] to male thread [R (PT) 1 /8] It can be used for mounting on a panel (1 to 3.2 mm to in thick). It protects the sensor s adjustment panel. (It can be fitted when the panel mounting bracket is used.) Relay contact With BCD output This is a very small controller which allows two independent threshold level settings. Supply voltage: 24 V DC 10 % No. of inputs: 1 No. (sensor input) Input range: 1 to 5 V DC Main functions: Threshold level setting function, zero-adjust function, scale setting function, hysteresis setting function, start / hold function, autoreference function, power supply -delay function, etc. This is a multi-functional controller having mathematical functions, hold function, etc. Supply voltage: 100 to 240 V AC 10 % No. of inputs: 2 Nos. (sensor inputs) Input range: 1 to 5 V DC Power supply for sensor: 12 V DC, 150 ma Main functions: Mathematical functions, process number selection function, hold function, scaling function, auto-reference function, power supply -delay function, measurement start delay function, hysteresis setting function, etc. Note: For further details, refer to p.864 l for the ultra-compact digital panel controller CA2 series, and to p.854l for the digital panel controller CA series. ] ] Two M4 (length 6 mm in) pan head screws and two spring washers are attached. Straight bush DPX-03 Straight bush Panel mounting bracket, Front protection cover MS-DPX-2 DPX-04 Front protection cover DPX kPa Digital panel controller CA2 series kPa Two M4 (length 6 mm in) pan head screws and two spring washers are attached. Panel mounting bracket MS-DPX-2 Suitable for 1 to 3.2 mm ( to in thick panel ) CA series
6 SCIFICATIS Item Type of pressure Rated pressure range Set pressure range Pressure withstandability Applicable fluid Selectable units Supply voltage Current consumption outputs Output 1 Output 2 ( ) Utilization category Output modes Hysteresis Repeatability Response time Short-circuit protection Analog voltage output Display Displayable pressure range Analog bar display Operation Output 1 indicators Output 2 Pollution degree Protection Ambient temperature Ambient humidity EMC Voltage withstandability Insulation resistance Vibration resistance Shock resistance Temperature characteristics Pressure port European Environmental resistance Material Model No. Cable Cable extension Weight Accessories Type (Note) European Vacuum pressure Positive pressure 101kPa type 100kPa type 1MPa type Standard Light weight Flat IP67 Standard Flat IP67 Standard Flat IP F(-P) -40N -60N -21F(-P) -41N -61N -22F(-P) -42N -62N -40E -60E -41E -61E -42E -62E Gauge pressure 0 to kpa 0 to kpa 0 to MPa 5.1 to kpa 5.0 to kpa to MPa to kgf/cm 2, to bar to 1.0 kgf/cm to 10. kgf/cm to psi, 38 to 760 mmhg to bar 0.50 to bar 1.5 to 29.9 inhg 0.72 to psi 7.2 to psi 490 kpa 1.47 MPa Non-corrosive gas kpa, kgf/cm 2, bar, psi, mmhg, inhg kpa, kgf/cm 2, bar, psi MPa, kgf/cm 2, bar, psi to 24 V DC 15 % Ripple P-P 10 % or less 50 ma or less <, (Standard NPN output, flat and IP67 types)> < (Standard PNP output type), European> Maximum sink current: 100 ma Maximum source current: 100 ma Applied voltage: V DC or less (between comparative output and 0 V) Applied voltage: V DC or less (between comparative output and V) Residual voltage: 1 V or less (at 100 ma sink current) Residual voltage: 2 V or less (at 100 ma source current) 0.4 V or less (at 16 ma sink current) DC-12 or DC-13 Equipped with 4 types of modes: hysteresis mode, window comparator mode, dual output mode, automatic sensitivity setting mode (selectable by key operation) 1 digit (however, variable in hysteresis mode and 2 digits when using psi unit) Within 0.2 % F.S. 1 digit 2.5 ms or less Incorporated Output voltage: 1 to 5 V (over rated pressure range) Zero-point: within 1 V 5 % F.S. Span: within 4 V 5 % F.S. Linearity: within 1 % F.S. Output impedance: 1 kω approx. 3 1 /2 digit red LED display (Sampling rate: 4 times/sec. approx.) 5.1 to kpa 5.0 to kpa to MPa to kgf/cm 2, to bar to 1.0 kgf/cm to 10. kgf/cm to psi, 38 to 760 mmhg to bar 0.50 to bar 1.5 to 29.9 inhg 0.72 to psi 7.2 to psi LED bar display in steps of 10 % F.S. approx. Orange LED (lights up when Output 1 is ) Green LED (lights up when Output 2 is ) 3 (Industrial environment) Standard, Flat and Light weight types: IP40 (IEC), IP67 type: IP67 (IEC) 10 to 50 C 14 to 122 F (No dew condensation or icing allowed), Storage: 10 to 60 C 14 to 140 F 35 to 85 % RH, Storage: 35 to 85 % RH EN , EN , EN ,000 V AC for one min. between all supply terminals connected together and enclosure 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure 10 to 150 Hz frequency, 0.75 mm 0.0 in amplitude in X, Y and Z directions for two hours each 100 m/s 2 acceleration (10 G approx.) in X, Y and Z directions for three times each Over ambient temperature range 10 to 50 C 14 to 122 F : within 1 % F.S. of detected pressure at C 68 F Standard, Flat and IP67 types:, Light weight type: M5 Standard type: NPTF 1 /8, Flat and IP67 types: NPT 1 /8 Flat and IP67 types: G (PF) 1 /8 Front case: ABS, Rear case: PPS (glass fiber reinforced), Display surface: Acrylic Pressure port attachment: Die-cast zinc alloy [Light weight type: POM (glass fiber reinforced), pressure port is brass (nickel plated)] Front cover (IP67 type only): Polycarbonate 0.15 mm 2 5-core oil resistant cabtyre cable, 2 m ft long (IP67 type: 5 m ft long) Extension up to total 100 m ft (less than 10 m ft when conforming to CE marking) is possible with 0.3 mm 2, or more, cable. Standard type: 95 g approx., Flat type: 1 g approx., IP67 type: 370 g approx., Light weight type: 70 g approx. Hexagon-socket-head plug for pressure port: 1 pc. (Standard type only), Pressure unit label: 1 pc. Note: Model Nos. of standard type having the suffix -P are PNP output type. Output voltage (V) 5 1 Pressure High pressure (Positive pressure type) High vacuum (Vacuum pressure type) DP3 797
7 I/O CIRCUIT AND WIRING DIAGRAMS NPN output type I/O circuit diagram Wiring diagram Sensor circuit Tr2 Tr1 D 1 kω ZD3 ZD2 ZD1 Internal circuit Color code (Brown) V (Gray) Analog voltage output (Note1, 2) (Black) Output ma max. (White) Output 2 (Blue) 0 V Users circuit Load 100 ma max. Load 12 to 24 V DC % kPa DP3 Notes:1) When using the analog voltage output, take care to connect external device of proper input impedance. Also, when a cable extension is used, voltage drop due to cable resistance should be taken into account. Notes:2) The analog voltage output does not incorporate a shortcircuit protection circuit. Notes: Do not connect it directly to a power supply or a capacitive load. Symbols... D: Reverse supply polarity protection diode ZD1, ZD2, ZD3: Surge absorption zener diode Tr1, Tr2: NPN output PNP output type Brown Gray Black White Blue To analog input circuit Load Load 12 to 24 V DC % I/O circuit diagram Wiring diagram Sensor circuit Tr1 Tr2 ZD1 ZD2 1 kω ZD3 D Color code (Brown) V (Black) Output ma max. (White) Output 2 (Gray) Analog voltage output (Note1, 2) (Blue) 0 V 100 ma max. Load Load Internal circuit Users circuit Notes:1) When using the analog voltage output, take care to connect external device of proper input impedance. Also, when a cable extension is used, voltage drop due to cable resistance should be taken into account. Notes:2) The analog voltage output does not incorporate a shortcircuit protection circuit. Notes:2) Do not connect it directly to a power supply or a capacitive load. Symbols... D: Reverse supply polarity protection diode ZD1, ZD2, ZD3: Surge absorption zener diode Tr1, Tr2: PNP output 12 to 24 V DC % -41E 100kPa Brown Black White Gray To analog input circuit Blue Load Load 12 to 24 V DC %
8 PRECAUTIS FOR PROR USE All models This product is not a safety sensor. Its use is not intended or designed to protect life and prevent body injury or property damage from dangerous parts of machinery. It is a normal pressure detection sensor. The series is designed for use with noncorrosive gas. It cannot be used with liquid or corrosive gas. Operation If setting is impossible even with pressing the key, verify whether the key-protect function is enabled. Please note that pressing down on the key for an extended moment will enable the key-protect function as soon as the key is released. If using the window comparator mode, set the pressure value so that there is a difference of 3 digits, or more, between Set Value 1 (P-1) and Set Value 2 (P-2). No output will be possible with a 0 to 2 digit difference. Functional description kPa 3 Error messages When an error occurs, take the following corrective action. Error message Cause Corrective action Overcurrent due to shortcircuit. Pressure is being applied during zero-point adjustment. Positive pressure type Vacuum pressure type Positive pressure type Vacuum pressure type Applied pressure exceeds the upper limit of displayable pressure range. Applied pressure exceeds the lower limit of displayable pressure range. Applied pressure exceeds the lower limit of displayable pressure range. Applied pressure exceeds the upper limit of displayable pressure range. Switch off the power supply and check the load. Applied pressure at the pressure port should be brought to atmospheric pressure and zero-point adjustment should be done again. Applied pressure should be brought within the rated pressure range. DP Description 3 1 /2 digit LED display (Red) Displays measured pressure, settings, error messages and key-protect status. Output 1 operation indicator Lights up when Output 1 is. (Orange) Output 2 operation indicator Lights up when Output 2 is. (Green) Increment key ( Decrement key ( ) ) In the initial setting mode, pressing the key changes the settable digit. In the Set Value 1, 2 modes, pressing the key changes the set value to the high pressure side in case of positive pressure type sensor and to the high vacuum side in case of vacuum pressure type sensor. In the sensing mode, if the key is pressed continuously for 4 sec. or more, the display shows peak hold value. In the initial setting mode, pressing the key changes the set conditions. In the Set Value 1, 2 modes, pressing the key changes the set value to the low pressure side in case of positive pressure type sensor and to the low vacuum side in case of vacuum pressure type sensor. In the sensing mode, if the key is pressed continuously for 4 sec. or more, the display shows bottom hold value. Mode selection key ( ) In the sensing mode, if both the keys are pressed simultaneously, zero-point adjustment is done. Each press of the key changes the selected mode to sensing mode, Set Value 1 (P-1) set mode and Set Value 2 (P-2) set mode. In the sensing mode, if the key is pressed continuously for about 3 sec., key-protect can be set / released. In the sensing mode, if the mode selection key is pressed while pressing the increment key ( ), the initial setting mode is obtained. 6 Function Wiring The analog voltage output does not incorporate a shortcircuit protection circuit. Do not directly connect a power supply or a capacitive load. Make sure that the power supply is off while wiring. Verify that the supply voltage variation is within the rating. If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. Conditions in use for CE conformity The series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN (Note) and the following condition must be met to conform to that standard. Condition The sensor should be connected less than 10 m ft from the power supply. Note: The EN that previously applied to the products for conforming to EMC Directive was replaced by EN starting April 1st,
9 PRECAUTIS FOR PROR USE All models Setting If key-protect has been set, make sure to release key-protect before operating the keys. (Please refer to Key-protect function on p.801 for the procedure.) Set Value 1 (P-1) and Set Value 2 (P-2) can be made common for all the output modes. The setting of Set Value 2 (P-2) with respect to Set Value 1 (P-1) can only be towards the high pressure side in case of the positive pressure type sensor and only towards the high vacuum side in case of the vacuum pressure type sensor. Set Value 3 (P-3) is automatically set to the mid-value of Set Value 1 (P-1) and Set Value 2 (P-2). (When setting the pressure value for the automatic sensitivity mode) The conditions which are set are stored in an EEPROM. Kindly note that the EEPROM has a life span and its guaranteed life is 100,000 write operation cycles. Setting procedure DP3 1 Zero-point adjustment Adjust zero-point 2 Initial setting Set Display, Output mode, and Unit 1 Zero-point adjustment The displayed pressure when the pressure port is left open is adjusted to zero. - The sensor will automatically enter the sensing 101.3kPa mode when power is supplied. Let the pressure port be at atmospheric pressure (i.e., no applied pressure condition), and press, simultaneously, the increment and decrement keys continuously. is displayed and, when the fingers are released, zero-point adjustment is completed and the sensor returns to the sensing mode. 2 Initial setting Pressure Unit, Display and Output mode of the comparative outputs are set. In the sensing mode, press key while pressing key kPa Initial setting is displayed. If sensor is being used for the first time, is displayed. The settable digit blinks. The settable digit changes when key is pressed and the setting is changed when key is pressed. Positive pressure type Vacuum pressure type : kpa or MPa : kgf/cm 2 : bar : psi : mmhg : inhg Change with key 3rd digit 2nd digit 1st digit Unit Output mode Display : Hysteresis mode : Window comparator mode : Dual output mode : Automatic sensitivity setting mode : Digital display : Analog bar display 3 Pressure value setting Enter Set Value 1 (P-1), Set Value 2 (P-2), Set Value 3 (P-3) Measurement Commence measurement on completion of setting 3 Pressure value setting For the case when output mode is set to either hysteresis mode ( ), window comparator mode ( ) or dual output mode ( ). Set Value 1 (P-1) and Set Value 2 (P-2) of the comparative outputs are set. Press key in the sensing mode to set to Set kPa Value 1 (P-1) set mode. Enter Set Value 1 (P-1) using key and key. Then, press key to set to Set Value 2 (P-2) set mode. Enter Set Value 2 (P-2) using key and key. Then, press key to set to sensing mode. For the case when output mode is set to automatic sensitivity setting mode ( ). Set Value 1 (P-1), Set Value 2 (P-2) and Set Value 3 (P-3) of the comparative outputs are set kPa Press key in the sensing mode to set to Set Value 1 (P-1) set mode. Within the required permissible pressure range, having created a pressure state which is nearest to the atmospheric pressure, press key to enter Set Value 1 (P-1). Then, press key to set to Set Value 2 (P-2) set mode. Within the required permissible pressure range, having created a pressure state which is nearest to the high pressure end (for a positive pressure type sensor) or the high vacuum end (for a vacuum pressure type sensor), press key to enter Set Value 2 (P-2). Then, press key to set to Set Value 3 (P-3) set mode. Check Set Value 3 (P-3) which has been set automatically. When Set Value 3 (P-3) is to be changed, enter Set Value 3 (P-3) using key and key. After checking and setting, press key to set to sensing mode. The automatically set Set Value 3 (P-3) can be manually changed to a value between Set Value 1 (P-1) and Set Value 2 (P-2). If using the window comparator mode, set the pressure value so that there is a difference of 3 digits, or more, between Set Value 1 (P-1) and Set Value 2 (P-2). No output will be possible with a 0 to 2 digit difference.
10 PRECAUTIS FOR PROR USE All models Conversion of pressure units In the series, the conversion to different units is automatically done on changing the setting of the pressure unit. However, this conversion can also be obtained by multiplying the values by the coefficients given in the table on the right. Conversion procedure For example, if 2 kpa is to be expressed in kgf/cm 2, since 1 kpa kgf/cm 2, 2 kpa becomes c 0.0 kgf/cm 2. Conversion table for pressure units kpa MPa kgf/cm 2 bar psi mmhg (Torr) 1 kpa MPa kgf/cm bar psi mmhg (1 Torr) 1 inhg atm inhg atm Key-protect function Key-protect is a function which prevents any unintentional change in the conditions which have been entered in each setting mode by making the sensor not to respond to the key operations kPa 101.3kPa Setting of key-protect In the sensing mode, press key continuously for about 3 sec. and release it immediately when is displayed. Key-protect is set and the sensor returns to the sensing mode. Release of key-protect In the sensing mode, press key continuously for about 3 sec. and release it immediately when is displayed. Key-protect is released and the sensor returns to the sensing mode. Others Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (0.5 sec.) after the power supply is switched on. Avoid use of standard type, flat type and light weight type of sensors in places where steam and dust is excessive. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. Do not operate the keys with pointed or sharp objects. DP3 801
11 PRECAUTIS FOR PROR USE Standard type Setting of pressure lead direction The pressure lead direction can be changed by dismantling the pressure port attachment and changing the mounting direction. The tightening torque of the hexagon-socket-head bolt (length: 9 mm in or less) should be 0.29 N m or less. Note: Make sure to close any unused pressure port with the hexagonsocket-head plug supplied as accessory. Main body Hexagon-socket-head bolts Mounting When mounting the sensor with the sensor mounting bracket, etc., the tightening torque should be 1.2 N m or less. M4 (length 6 mm in) pan head screw (Accessory for MS-DPX) Spring washer (Accessory for MS-DPX) Sensor mounting bracket MS-DPX (optional) DP3 Pressure port attachment Hexagon-socket-head plug Pressure ports Piping When connecting a hexagon-socket-head plug or coupling to the pressure port, hold the hexagonal part of the pressure port with a 12 mm in spanner and make sure that the tightening torque is 9.8 N m or less. Also, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. However, sealing tape is not required for type (- F ) using NPTF 1 /8 coupling. (Sealing tape is required if NPT 1 /8 coupling is used.) 12 mm in spanner Flat type Light weight type Setting of pressure lead direction The pressure lead direction can be changed by dismantling the pressure port attachment and changing the mounting direction. The tightening torque of the hexagon-socket-head bolt (length: 9 mm in or less) should be 0.29 N m or less. Pressure port attachment Hexagon-socket-head bolts Piping When connecting a coupling to the pressure port, hold the pressure port attachment with a 16 mm 0.6 in (light weight type: 10 mm in) spanner and make sure that the tightening torque is 9.8 N m or less (light weight type: 1.47 N m or less). Also, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. Main body 2-"4.3 mm "0.169 in mounting holes Pressure port 16 mm 0.63 in (light weight type: 10 mm in) spanner
12 PRECAUTIS FOR PROR USE IP67 type Piping for pressure measurement inlet port When connecting a coupling to the pressure measurement inlet port, hold the pressure port attachment with a spanner and make sure that the tightening torque is 9.8 N m or less. Also, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. Piping for atmospheric pressure inlet port If there is a possibility of water entering into the sensor enclosure through the atmospheric pressure inlet port, connect a tube to the atmospheric pressure inlet port through a M5 coupling and extend the other end of the tube to a safe place. In this case, ensure that this end of the tube does not get clogged. Safe place, where there is no exposure to water Atmospheric pressure inlet port M5 coupling Tube Pressure measurement inlet port Fitting of front cover Insert the bosses on the front cover into the guide holes at the bottom of the pressure port attachment, and push in the direction of the arrow to fit the hook. When removing the front cover, release the hook first. Hook Guide holes DP3 803
13 DIMENSIS (Unit: mm in) Standard type The CAD data in the dimensions can be downloaded from the SUNX website (2.1) (0.083) (25.8) (1.016) 3 1 /2 digit LED display (Red) M3 hexagon-socket-head bolts 2-M4 DP3 (6)(0.236) (18.9) (0.744) (10.9) (0.429) Increment key Decrement key (9) (0.354) (18) (0.709) (11) (0.433) Output 2 operation indicator (Green) Note: NPTF 1 /8 for type. -80 Light weight type Mode selection key Output 1 operation indicator (Orange) "3.7 "0.146 cable, 2 m ft long Pressure port (Note) (2.1) (0.083) (25.8) (1.016) 3 1 /2 digit LED display (Red) (23.7) (0.933) (15.7) (0.618) (10.8) (0.425) "8 "0.315, deep 2-"4.3 "0.169 mounting holes (9) (0.354) (18) (0.709) (11) (0.433) Output 2 operation indicator (Green) Mode selection key Output 1 operation indicator (Orange) Decrement key Increment key Pressure port M5, deep "3.7 "0.146 cable, 2 m ft long Flat type (2.1) (0.083) (25.8) (1.016) 3 1 /2 digit LED display (Red) (27.9) (1.098) (19.9) (15) (0.783) (0.591) "8 "0.315, deep 2-"4.3 "0.169 mounting holes (9) (0.354) (18) (0.709) (11) (0.433) Output 2 operation indicator (Green) Mode selection key Output 1 operation indicator (Orange) Decrement key Increment key Pressure port (Note) "3.7 "0.146 cable, 2 m ft long Note: NPT 1 /8 for type, and G (PF) 1 /8 for European type.
14 DIMENSIS (Unit: mm in) The CAD data in the dimensions can be downloaded from the SUNX website IP67 type (10.1) (0.398) (25.8) (1.016) 3 1 /2 digit LED display (Red) (11) (0.433) (45.1) (1.776) (37.1) (1.461) (32.2) (1.268) Output 2 operation indicator (Green) Mode selection key Output 1 operation indicator (Orange) Decrement key Increment key 2-"4.5 "0.177 mounting holes (9) (0.354) (18) (0.709) "3.7 "0.146 cable, 5 m ft long Atmospheric pressure inlet port M5, deep DP Pressure measurement inlet port (Note) Note: NPT 1 /8 for type, and G (PF) 1 /8 for European type. MS-DPX Sensor mounting bracket for standard type (Optional) 2-"4.2 "0.165 mounting holes Assembly dimensions "4.2 "0.165 mounting holes "4.2 "0.165 mounting holes Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) t Two M4 (length 6 mm in) pan head screws and two spring washers are attached
15 DP3 DIMENSIS (Unit: mm in) The CAD data in the dimensions can be downloaded from the SUNX website MS-DPX-4 3-"4.2 "0.165 mounting holes "4.5 "0.177 mounting hole Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M4 (length 6 mm in) pan head screws and two spring washers are attached. MS-DPX-2 DPX-04 Assembly dimensions Back angled mounting bracket for standard type (Optional) Mounting oblong hole Assembly dimensions Mounting oblong hole "4.5 "0.177 mounting hole Panel mounting bracket, front protection cover for standard type (Optional) Panel cut-out dimensions portion shows the front protection cover. Material: Polycarbonate (Front protection cover) Nylon 6, Stainless steel (SUS4)(Panel mounting bracket) Note: The panel thickness should be 1 to 3.2 mm to 0126 in.
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small
EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
U-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing
Ordering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs
857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
LCD Readout Digital Pressure Switch
LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
Electronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)
Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
Givare NC-SRS 280 och 880
Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Duct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
How To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
Digital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
Incremental Rotary Encoder E6B2
Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function
RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor
DMP Industrial Pressure Transmitter for Low Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO from 0... 00 mbar up to 0... 40 bar Output signals
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
Proportional pressure regulators VPPE
Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
Thermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
Vario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Electronic Pressure Switch EDS 3000
For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250
MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic
Temperature sensor with integrated transmitter for industrial applications, MBT 3560
Temperature sensor with integrated transmitter for industrial applications, MBT 3560 Technical brochure Features Designed for use in harsh industrial enviroments where reliable, robust and accurate equipment
3 Port Solenoid Valve
Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large
T0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1
No. : EX##-OMF0004 OPERATION MANUAL EX12#-SMB1 Contents 1. Safety instructions ------------------------------------------------------ P3 2. Notes ------------------------------------------------------
E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
Technical Information RIA14
TI00143R/09/EN/04.14 71256618 Products Solutions Services Technical Information RIA14 Loop powered field indicator With explosion proof enclosure (according to Ex d) Application Oil & gas Petrochemical
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
RPS 8000. High Accuracy Resonant Pressure Sensor. GE Measurement & Control Solutions. Features:
GE Measurement & Control Solutions RPS 8000 High Accuracy Resonant Pressure Sensor For over 35 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in
DCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
Technical Data. Dimensions
0102 Model Number Features 15 mm quasi flush Usable up to SIL2 acc. to IEC 61508 Accessories BF 30 Mounting flange, 30 mm V1-G-N-2M-PUR Female cordset, M12, 2-pin, NAMUR, PUR cable V1-W-N-2M-PUR Female
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Bulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61
Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS
Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature
WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100
WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.
POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE
POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.
Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]
Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]
PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
Panel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies
25.2W/in 3 power density Internal ORing MOSFET & Current Share Climate Savers Computing efficiency standards Up to 8000W in 1U rack Single and dual output 1U racks PMBus option HFE1600 Series 1600W 1U
W150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
Model 43AP Pneumatic Controller, Style B
Instruction MI 011-476 January 1980 Model 43AP Pneumatic Controller, Style B Installation and Operation Model 43AP Controller continuously detects the difference between a process measurement and its set
Conductive Level Switch FK 2 Technical Data:
Level switch for conductive liquids Optional electrode length adjustment Hygienic installation in accordance with EHEDG Wetted parts compatible with FDA requirements Potted electronic Not influenced by
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
NX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
VOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via
CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)
TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output
Multifunction Digital Timer
Multifunction Digital Timer 1/16 DIN Timer with Easy-to-use Functions Nine output modes accommodate a wide variety of applications. All parameters set by scroll-through menus accessed from the front panel.
MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
2.24. Pump Controller 704. Data Sheet
Pump Controller 704 2.24 There are several reasons to choose an MJK pump controller. Pump controller 704, as described in this data sheet, was introduced in 1989. It has been updated several times with
VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series
Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,
MULTI-BEAM LS10 Light Screen System
For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small
Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm
Model Number Features Increased operating distance 8 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications
CAUTION OPC-LM1-ID. Option Card for Frequency Divider. Fuji Electric FA Components & Systems Co., Ltd. Instruction Manual
Instruction Manual Option Card for Frequency Divider Deliver this instruction manual without fail to those who actually operate the equipment. Read this operation manual and understand the description
E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test
Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection
Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.
ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection
RPS/DPS 8100. High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:
GE Measurement & Control RPS/DPS 8100 High Accuracy Resonant Pressure Sensor For over 40 years, Druck has manufactured precision pressure sensors with a capability to meet critical applications in industrial,
Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor
Special Features Wetted parts in stainless steel and PEEK Compact design Precise switching point with no requirement for calibration Process temperature 0... 5 C Measures media with DKvalues >.5 (DK =
48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.