Digital Flow Switch for Water 3 -color/2-screen display

Size: px
Start display at page:

Download "Digital Flow Switch for Water 3 -color/2-screen display"

Transcription

1 3-color display New Digital Flow Switch for Water 3 -color/-screen display RoHS Main screen Sub screen Note 3) Main screen Sub screen Note 3) Instantaneous flow rate Set value Note ) ccumulated value Peak/ottom value Instantaneous flow rate Note ) Note ) Main screen shows the instantaneous flow rate only. Note ) Fluid temperature can be displayed only when the digital flow switch with a temperature sensor is selected. Note 3) Sub screen can be turned off. Line name Fluid temperature Note ) New Flow range: Line up 5 L type Integrated flow adjustment valve and temperature sensor Flow adjustment valve Remote type PVC piping type Temperature sensor Series Remote sensor unit Remote type 3-color display Digital flow monitor pplicable fluid: Deionized water, chemical, etc. Integrated type and remote type added to series. IP65 CT.ES-8C

2 Digital Flow Switch for Water 4% 4% smaller than existing product Reducing piping space Shortened 74-3 PFW74-3 (Existing product) 3 5 Straight piping length 4 PFW74 74 Existing product requires a straight piping length at least 8 times the piping diameter. Refer to straight piping length and accuracy. (pages 5 and 3) Temperature sensor Display range: to C (Temperature sensor alone) Minimum setting unit: C nalog output: Current output/voltage output Flow adjustment valve Space saving and reduced piping labor Temperature display Temperature sensor Fluid temperature: to 9 C Ethylene glycol aqueous solution can be used Example) Flow control of the circulating fluid in a chiller Customer s machine Rotatable display Display can be rotated in increments of 45 to suit the installation conditions. Easy operation, improved visibility. Counterclockwise 9 Clockwise 5 35 turn OUT IN OUT (No rotation) Non-grease OUT IN IN Mounting 8 turn 9 turn racket mounting Direct mounting Panel mounting Front protective cover Panel mount adapter Features Tapping screw (4 pcs.) Waterproof seal (accessory) Panel Mounting screw (M3 x 8 L) (accessory)

3 Series PVC piping Integrated type Remote sensor to 6 3/8,/ Ethylene glycol aqueous solution 5 to 4 /,3/4 Deionized water Chemical Monitor 3/4, to 5 4, to 5 3 to New 5 New 3 to 5 How to Order Specifications (Integrated Display) Specifications (Remote Sensor Unit) 3 Flow-rate Characteristics (Pressure Loss) 5 Wetted Parts Construction 6 Dimensions 7 3-color display Digital flow monitor can copy to up to The settings of the master sensor (source of copy) can be copied to the slave sensors. Made to Order switches simultaneously. Copy Reducing setting labor sensor Slave side unit Minimizing risk of Master (source of copy) (copy destination) mistakes in setting 3-Color Display Digital Flow Switch for PVC Piping How to Order Specifications (Integrated Display) units units Specifications (Remote Sensor Unit) 3 Wetted Parts Construction 4 Dimensions 5 Made to Order 7 Indicator Visually check status of sensor via indicator. Reducing wiring labor by connector e-con connector No tools and peeling required 3-Color Display Digital Flow Monitor for Water 3 How to Order 8 Specifications 9 Dimensions M8 connector Flow rate: High linking green/fast Flow rate: Low linking green/slow Rated flow or less OFF Rated flow or more Red ON PVC piping type Monitor 3/8 3-Color Display Digital Flow Switch for Water sensor.5 to 4 Water 3-Color Display Digital Flow Switch for Water Power supply/output connection lead wire Remote Flow adjustment valve/temperature sensor Port size Flow Flow adjustment None adjustment Temperature valve + Temperature Rc, NPT, G sensor valve sensor 3-Color Display Digital Flow Switch for PVC Piping Integrated Rated flow range (L/min) 3 pplicable fluid Type INDEX 3-Color Display Digital Flow Monitor for Water Variations 5 L/min added Wetted Parts Pipe CPVC (Heat resistant PVC) Function Details ody PPS pplicable Fluid 4 Seal FKM Features Function Details Measured flow rate

4 3-color display Digital Flow Switch for Water Series How to Order RoHS For how to order of remote monitor unit, refer to page 8. Symbol Nil S Remote sensor unit Integrated display Note ) External input: The accumulated value, peak value, and bottom value can be reset. Note ) For units with temperature sensor, OUT can be set as either temperature output or flow rate output. Setting when shipped is for temperature output. Remote sensor unit Output specification/temperature sensor Options/Part No T T M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range 4.5 to 4 L/min to 6 L/min 4 5 to 4 L/min to L/min 5 to 5 L/min Thread type Nil Rc N NPT F G ISO8 equivalent Port size Integrated display Output specification/temperature sensor OUT OUT Symbol Flow rate Flow rate Temperature nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m External input Note ) External input Note ) () () Note ) Note ) (nalog to 5 V) Note ) nalog to 5 V C D E F G H T T CT DT ET FT (nalog 4 to m) (nalog to 5 V) (nalog 4 to m) Symbol Port size 3 3/8 4 / 6 3/4 / /4 4 / 4 Rated flow range 4 nalog 4 to m nalog to 5 V nalog 4 to m When optional parts are required separately, use the following part numbers to place an order. Description Part no. ZS-4-K racket Note) ZS-4-L ZS-4-M Lead wire with M8 connector ZS-4- OUT Symbol Flow rate nalog to 5 V nalog 4 to m T nalog to 5 V Flow adjustment valve With/without flow Rated flow range adjustment valve 4 4 None Yes Note ) and 5 L/min types with flow adjustment valves are not available. Note ) The flow adjustment valve of this product is not suitable for applications which require constant adjustment of flow rate. To use in combination with remote monitor (3 series), select analog output of to 5 V of flow rate (output symbol - or -T ). Note) nalog output of 4 to m with temperature sensor is made to order. (Refer to page.) Qty. Note ) Note ) Note ) For 74/7/54/5 For 74/54 For 7/5 Note) For units with flow adjustment valve, brackets are required. OUT Temperature nalog to 5 V Note Lead wire length (3 m) Temperature sensor None With temperature sensor Temperature sensor None With temperature sensor With 4 tapping screws (3 x 8) With 4 tapping screws (3 x 8) With 4 tapping screws (4 x ) The certificate is written in both English and Japanese. Integrated display type with temperature sensor can only display flow rate. racket (Option) Nil None racket R Made to Order X9 Seal material EPDM X8 nalog 4 to m output type Note) X43 Piping material brass Note) pplicable only for remote type with temperature sensor (Refer to page.) Calibration certificate (Only flow sensor) Nil None With calibration certificate Note) With bracket is not available for 5 L/min type. Integrated display/unit specification Symbol M G F J Remote sensor unit/unit printed on label Symbol Instantaneous flow rate Temperature Nil L/min C L/min G C/F (gal/min) Under the New Measurement Law, units other than SI (symbol Nil ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].64 [gal/min] [gal/min] [L/min] F = 9/5C + 3 Instantaneous flow rate L/min gal/min gal/min L/min ccumulated flow L gal gal L Temperature C C F F Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].64 [gal/min] [gal/min] [L/min] F = 9/5C + 3 Lead wire Nil With lead wire with M8 connector (3 m) N Without lead wire with M8 connector

5 3-color display Digital Flow Switch for Water Series Specifications (Integrated Display) Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Model pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min to 6 L/min 5 to 4 L/min to L/min 5 to 5 L/min Display flow range.35 to 5.5 L/min.7 to. L/min 3.5 to 55. L/min 7 to 4 L/min to 35 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) (Flow under L/min is displayed as ) Set flow range.35 to 5.5 L/min.7 to. L/min 3.5 to 55. L/min 7 to 4 L/min to 35 L/min Minimum setting unit. L/min. L/min L/min L/min Conversion of accumulated pulse (Pulse width: 5 ms).5 L/pulse. L/pulse.5 L/pulse L/pulse L/pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss (without flow adjustment valve) to 9C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L Display value: 3% F.S. nalog output: 3% F.S. % F.S. Note ) 5% F.S. (5C reference) to MPa.5 MPa 45 kpa or less at the maximum flow 6 kpa or less at the maximum flow ccumulated flow range Note 4) Switch output Maximum load current Maximum applied voltage Internal voltage drop Response time Note ), 5) Output protection Output Flow rate mode Temperature Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 7) Insulation resistance Standards and regulations Wetted parts material Note 8) Piping port size Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Weight Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note ) When.5 s is selected for the response time of the switch output, the repeatability becomes 3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to page 4. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 4 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 6) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 7) When the temperature sensor is used, it will be 5 VC. Note 8) Refer to Wetted Parts Construction on page 6 for details. Note 9) External scratch marks and dirt are judged as good parts provided that they do not affect product performance. Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit Display accuracy nalog output accuracy Response time mbient temperature characteristics Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9C. Note ) The response time is for the temperature sensor alone. y. L y.5 L y L or open collector output 8 m 8 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5 s/ s/ s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode..5 s/ s/ s (linked with the switch output) Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer -screen display (Main screen: 4-digit, 7-segment, -color, Red/Green Sub screen: 6-digit, -segment, White) Display values updated 5 times per second Output, Output : Orange to 4 VDC % 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 g 85 g 3 g 385 g L L to C Note ) to C C C C 3% F.S. 7 s Note ) 5% F.S. 3/8, / 6 g 335 g 36 g 435 g /, 3/4 4 g 53 g 6 g 73 g +85 g 3/4, 7 g 86 g The output related to the temperature sensor is OUT only. Flow rate detecting circuit Temperature detecting circuit Main circuit OUT Switch output OUT Switch output nalog output /4, / 89 g 75 g rown DC (+) lack OUT White OUT lue DC ( ) The OUT can be selected from the output for temperature or flow rate by button operation. 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

6 Series Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Specifications (Remote Sensor Unit) Refer to page 8 for monitor unit specifications. Model pplicable fluid Detection method Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex Rated flow range.5 to 4 L/min to 6 L/min 5 to 4 L/min to L/min 5 to 5 L/min Fluid temperature ccuracy Repeatability Temperature characteristics to 9C (with no freezing and condensation) 3% F.S. % F.S. 5% F.S. (5C reference) Operating pressure range Note ) Proof pressure Note ) Pressure loss (without flow adjustment valve) Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Note 4) Insulation resistance Standards and regulations Wetted parts material Note 5) Piping port size Without temperature sensor/without flow adjustment valve With temperature sensor/without flow adjustment valve Without temperature sensor/with flow adjustment valve With temperature sensor/with flow adjustment valve With lead wire with connector Weight Temperature Sensor Specifications to MPa Note ).5 MPa 45 kpa or less at the maximum flow 6 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC For power supply status, flow rate indicator (linking speed changes in response to flow rate), and other error indicator to 4 VDC % 3 m or less IP65 to 5C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, Stainless steel 34, FKM, SCS3 Non-grease 3/8 95 g 7 g 95 g 37 g 3/8, / 45 g 3 g 345 g 45 g /, 3/4 395 g 55 g 595 g 75 g +85 g 3/4, 75 g 84 g /4, / 875 g 6 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. e aware that water leakage may happen due to internal seal shrinkage or swelling depending on kinds of fluid. Note ) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Note 4) When the temperature sensor is used, it will be 5 VC. Note 5) Refer to Wetted Parts Construction on page 6 for details. Note 6) External scratch marks and dirt are judged as good parts provided that they do not affect product performance. Rated temperature range nalog output accuracy Response time mbient temperature characteristics to C Note ) 3% F.S. 7 s Note ) 5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9C. Note ) The response time is for the temperature sensor alone. Caution Sensor Set Flow Range and Rated Flow Range Set the flow within the rated flow range. The set flow range is the range of flow rate that is possible in setting. The rated flow range is the range that satisfies the sensor s specifications (accuracy etc.). lthough it is possible to set a value outside the rated flow range, the specifications will not be guaranteed even if the value stays within the set flow range. Flow range.5 L/min L/min 5 L/min L/min 4 L/min L/min 4 L/min 5 L/min 35 L/min.5 L/min.35 L/min.35 L/min L/min.7 L/min.7 L/min 5 L/min 3.5 L/min 3.5 L/min 4 L/min 5.5 L/min 5.5 L/min L/min 7 L/min 7 L/min L/min L/min L/min L/min 6 L/min L/min L/min 5 L/min 5 L/min 4 L/min 55 L/min 55 L/min L/min 4 L/min 4 L/min 5 L/min 5 L/min 8 L/min 8 L/min 35 L/min 35 L/min In the case of the 5 series, the displayable and settable ranges are the same as the 3 series flow monitor. 3 Rated flow range Display flow range Set flow range

7 3-color display Digital Flow Switch for Water Series nalog Output Flow rate/nalog output Voltage output Current output V 4 m Model.5 V 6 m 74/54 7/5 74/54 7/5 7/5 4/6/4 5.4 V 5.6 m C.8 V 5 V 7. m m Rated flow [L/min] Minimum Maximum Output C Minimum rated flow Operating Pressure and Proof Pressure MaximumFlow rate rated flow Fluid temperature/nalog output 7/5 Output Voltage output Current output Voltage output Current output.6 V.4 m C 5 V m V 4 m D 5.4 V.6 m D C C C C C Fluid temperature 3-Color Display Digital Flow Switch for Water 74/7/74/54/5/54 Pressure [MPa] 7/5 Pressure [MPa].6.4. Proof pressure [MPa].8.6 Operating pressure [MPa] Fluid temperature [C].6.4. Proof pressure [MPa].8.6 Operating pressure [MPa] Fluid temperature [C] 74S/7S/74S/54S/5S/54S Pressure [MPa] /5 Pressure [MPa] Proof pressure [MPa] Operating pressure [MPa] Fluid temperature [C] Operating pressure/ Proof pressure [MPa] Fluid temperature [C] 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details 4

8 Series Flow-rate Characteristics (Pressure Loss: Without Flow djustment Valve) 74/54 7/5 74/ Pressure loss [MPa].3.. Pressure loss [MPa].3.. Pressure loss [MPa] Flow rate [L/min] 7/ Flow rate [L/min] 7/ Flow rate [L/min].4.5 Pressure loss [MPa].3.. Pressure loss [MPa] Flow rate [L/min] Flow rate [L/min] Straight Piping Length and ccuracy (Reference Value) Straight piping length The smaller the piping size, the more the product is affected by the straight piping length. Fluid pressure has almost no affect. Low flow rate lessens the effect of the straight piping length. Use a straight pipe that is 8 cm or longer in length to satisfy the 3% F.S. specification. ( cm or longer for L/min and 5 L/min types) Pressure:.3 MPa Pressure:.3 MPa 74/54 Piping diameter: ø 7/5 Piping diameter: ø 74/54 ccuracy [% F.S.] /54-3 (at 4 L /min) Straight piping length [cm] Pressure:.3 MPa Piping diameter: 5 (Port size ) 7/5 (Port size 6) ccuracy [% F.S.] /5-6 (at 5 L /min) 7/5-6 (at L /min) 7/5- (at L /min) 7/5- (at 5 L /min) ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: 3 (Port size ) 7/5 4 (Port size 4) ccuracy [% F.S.] /5-3 (at 6 L /min) 7/5-4 (at 6 L /min) 7/5-3 (at 8 L /min) Straight piping length [cm] 7/5-4 (at 5 L /min) 7/5- (at 5 L /min) ccuracy [% F.S.] Pressure:.3 MPa Piping diameter: ø /54-4 (at 4 L /min) /54-6 (at 4 L /min) Straight piping length [cm] Straight piping length [cm] No data for 4 cm, or for under 5 cm, as these cannot be used due to piping dimensions Straight piping length [cm]

9 3-color display Digital Flow Switch for Water Series Flow-rate Characteristics of Flow djustment Valve 74S/54S 7S/5S 74S/54S Flow rate [L/min] P =.4 MPa P =.3 MPa P =. MPa P =. MPa P =.5 MPa 4 5 Number of rotations [rotations] P: Pressure differential between the front and the rear of product Measurable Range for Ethylene Glycol queous Solution (Reference Value) Flow rate [L/min]. 5.. P =.3 MPa 5. P =.5 MPa P =.4 MPa P =. MPa P =. MPa 4 5 Number of rotations [rotations] P: Pressure differential between the front and the rear of product Flow rate [L/min] P =.5 MPa P =.4 MPa P =.3 MPa P =. MPa P =. MPa Number of rotations [rotations] P: Pressure differential between the front and the rear of product 3-Color Display Digital Flow Switch for Water queous solution concentration [%] (Weight) Measurable within this range queous solution temperature [C] Wetted Parts Construction Component Parts No. Description ttachment Seal ody Sensor q r w w Temperature sensor Temperature sensor body Flow adjustment valve body Flow adjustment valve cover Flow adjustment valve shaft Shaft support Y seal Cap seal e y Material SCS3 Stainless steel 34 FKM PPS PPS Stainless steel 34 Stainless steel 34 PPS PPS Stainless steel 34 PPS FKM FKM o i t w u!! w! w Note Stainless steel 34 equivalent 74/7/74/7/54/5/54/5 7/5 With brazing JIS Z 36: g-7, ( ISO 3677: -g56cuznsn-6/65 ) 6 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

10 Series Dimensions 74/7/74/7/7 Integrated display Connector pin number Example 3 4 For 7 Pin no. 3 4 Pin name DC (+) OUT DC ( ) OUT G Z Y D.4 E F x Piping port 3 5 S (35.5) H J T U 4 4 x WX V W IN OUT G K L 4 x P G x Piping port N 54/5/54/5/5 Remote sensor unit Y F DD E J 3 V W G Z x Piping port S T U 4 x WX For 5 (35.5) H 4 IN OUT G K L 4 x P G x Piping port N Model 74/54 7/5 74/54 7/5 7 7/5 Port size (Rc, NPT, G) 3/8 3/8, / /, 3/4 3/4, /4, / G /4 G / D DD E F G H J K L N P ø.7 depth 4 ø.7 depth ø.7 depth ø3.5 depth 4 ø3.5 depth 4 S T 3 36 racket dimensions U V W WX Y (mm) Z

11 3-color display Digital Flow Switch for Water Series Dimensions 74/7/74/7--T Integrated display: With temperature sensor Model 74/54--T 7/5--T 74/54--T 7/5--T 7/5--T 7/5-F-T 7/5-F4-T D S (mm) 74S/7S/74S Integrated display: With flow adjustment valve T 54/5/54/5--T Remote sensor unit: With temperature sensor D S 54S/5S/54S Remote sensor unit: With flow adjustment valve T 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping Q Q K F L 4 x P N K F L 4 x P N 3-Color Display Digital Flow Monitor for Water 3 (mm) Model 74S/54S 7S/5S 74S/54S (Max. 68.6) 63.6 (Max. 68.6) 75.5 (Max. 8) D F K L N P ø.7 depth ø.7 depth ø.7 depth Q ø9 ø9 ø8 Q number of rotations racket dimensions S T Function Details

12 Series Dimensions 74S/7S/74S--T Integrated display: With temperature sensor and flow adjustment valve 54S/5S/54S--T Remote sensor unit: With temperature sensor and flow adjustment valve S D S D K K (mm) Model D K S 74S/54S--T 7S/5S--T 74S/54S--T ZS-4- Lead wire with M8 connector (lack) 4 (lue) 3 M8 (White) (rown) Pin no. Pin name Wire color 3 4 DC (+) OUT DC ( ) OUT rown White lue lack ø (3.8) ø4 (3) (45) (5) Lead Wire Specifications Conductor Insulator Sheath Finished O.D. Note ) 4-wire type lead wire with M8 connector used for the series. Note ) Refer to the Operation Manual in our website ( for wiring. Nominal cross section O.D. Material O.D. Color Material WG3 pprox..7 mm Heat resistant PVC pprox.. mm rown, White, lack, lue Heat and oil resistant PVC ø4 9

13 Series Made to Order Please consult SMC for detailed dimensions, specifications and delivery. Made to Order Seal material EPDM Seal material for wetted parts changed to EPDM 5 7 Refer to How to Order, page for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. X9 X9 Seal material EPDM Symbol -X9 3-Color Display Digital Flow Switch for Water nalog 4 to m output Output specification of remote type with a temperature sensor: nalog 4 to m output 5 X8 nalog 4 to m output Refer to How to Order, page for details. Note) Remote monitor unit is eguipped as standard. 3 Piping material brass Piping (attachment) material changed to brass Symbol -X8 Symbol -X43 3-Color Display Digital Flow Switch for PVC Piping 5 X43 7 Refer to How to Order, page for details. Note) Not compatible with units with flow adjustment valve. Please special-order separately. Surface treatment is not applied on piping. X43 Piping (attachment) material brass Piping (attachment) Function Details 3-Color Display Digital Flow Monitor for Water 3

14 For how to order of remote monitor unit, refer to page 8. Remote sensor unit Integrated display Options/Part No. 3-color display Digital Flow Switch for PVC Piping Series How to Order racket (Option) Nil R Lead wire Nil When optional parts are required separately, use the following part numbers to place an order. Description racket Lead wire with M8 connector 5 7 Symbol Remote sensor unit Output specification 5 U 7 U 5 M Type Remote sensor unit Integrated display Rated flow range (Flow range) Symbol Rated flow range to L/min 3 to 5 L/min Symbol 5 3 Part no. ZS-4-M ZS-4- OUT nalog to 5 V nalog 4 to m To use in combination with remote monitor (3 series), select analog output of to 5 V of flow rate (output symbol - ). Port size 5 3 Connection type U PVC pipe PVC pipe O.D. Rated flow range Pipe O.D. 3 mm 38 mm JIS K674 equivalent Symbol OUT OUT C D E F G H nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m External input External input External input: The accumulated value, peak value, and bottom value can be reset. Qty. Remote sensor unit/unit printed on label Symbol Instantaneous flow rate Temperature Nil L/min C L/min G C/F (gal/min) Under the New Measurement Law, units other than SI (symbol Nil ) cannot be used in Japan. Note) G: Made to Order Reference: [L/min].64 [gal/min] [gal/min] [L/min] F = 9/5C + 3 Integrated display Output specification None racket With lead wire with M8 connector (3 m) Note For 7/5 With 4 tapping screws (4 x ) Lead wire length (3 m) Calibration certificate (Only flow sensor) Integrated display/unit specification Symbol M G F J Instantaneous flow rate L/min gal/min gal/min L/min Nil None With calibration certificate The certificate is written in both English and Japanese. ccumulated flow L gal gal L Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].64 [gal/min] [gal/min] [L/min] F = 9/5C + 3 Made to Order X9 Seal material EPDM (Refer to page 7.) N Note) With bracket is not available for 5 L/min type. Temperature C C F F Without lead wire with M8 connector RoHS

15 3-color display Digital Flow Switch for PVC Piping Series Specifications (Integrated Display) Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Model pplicable fluid Detection method Rated flow range Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Fluid temperature Display unit ccuracy Repeatability Temperature characteristics Operating pressure range Note 3) Proof pressure Note 3) Pressure loss ccumulated flow range Note 4) Switch output Response time Note ), 5) Output protection Output mode Flow rate Response time Note 6) nalog output Voltage output Current output Hysteresis External input Display method Indicator light Power supply voltage Current consumption Wetted parts material Note 7) Piping port size Weight Maximum load current Maximum applied voltage Internal voltage drop Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Without lead wire with connector With lead wire with connector 7 7 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 3 to 5 L/min 7 to 4 L/min to 35 L/min (Flow under 7 L/min is displayed as ) (Flow under L/min is displayed as ) 7 to 4 L/min to 35 L/min L/min L/min L/pulse L/pulse to 7C (with no freezing and condensation) Instantaneous flow rate: L/min, ccumulated flow: L, Display values updated 5 times per second Display value: 3% F.S. nalog output: 3% F.S. % F.S. Note ) 5% F.S. (5C reference) to MPa MPa 45 kpa or less at the maximum flow L y L or open collector output 8 m 8 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current).5 s/ s/ s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode..5 s/ s/ s (linked with the switch output) Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer -screen display (Main screen: 4-digit, 7-segment, -color, Red/Green Sub screen: 6-digit, -segment, White) Output, Output : Orange to 4 VDC % 5 m or less IP65 to 5 C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease 5 85 g 37 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 4. Note ) When.5 s is selected for the response time of the switch output, the repeatability becomes 3% F.S. Note 3) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graph below. Note 4) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 4 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note 5) The response time when the set value is 9% in relation to the step input. Note 6) The response time until the set value reaches 9% in relation to the step input. Note 7) Refer to Wetted Parts Construction on page 4 for details. nalog Output Flow rate/nalog output Voltage output Current output Model V 4 m 7/5 7/5.4 V.5 V C 5 V 5.6 m 5.9 m m Rated flow [L/min] Minimum 3 Maximum 5 Output C Minimum rated flow Maximum Flow rate rated flow 3 34 g 45 g Operating Pressure/Proof Pressure 7/7/5/5 (for PVC Piping) Max. operating pressure [MPa] Fluid temperature [C] Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

16 Series Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Specifications (Remote Sensor Unit) Refer to page 9 for monitor unit specifications. Model pplicable fluid Detection method Rated flow range Fluid temperature ccuracy Repeatability Temperature characteristics Operating pressure range Note ) Proof pressure Note ) Pressure loss Response time Note 3) nalog output Voltage output Current output Indicator light Power supply voltage Current consumption Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Wetted parts material Note 4) Piping port size Weight Without lead wire with connector With lead wire with connector 5 5 Water and ethylene glycol aqueous solution (with viscosity of 3 mpa s [3 cp] or less) Note ) Karman vortex to L/min 3 to 5 L/min to 7C (with no freezing and condensation) 3% F.S. % F.S. 5% F.S. (5C reference) to MPa Note ) MPa 45 kpa or less at the maximum flow s Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC For power supply status, flow rate indicator (linking speed changes in response to flow rate), and other error indicator to 4 VDC % 3 m or less IP65 to 5C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS PPS, FKM, CPVC Non-grease g 35 g 355 g 4 g Note ) Refer to Measurable Range for Ethylene Glycol queous Solution on page 6. Measurement can be performed with a fluid that does not corrode wetted parts and has viscosity of 3 mpa s [3 cp] or less. Refer to the list of applicable fluids on page 4. Note ) Operating pressure range and proof pressure change according to the fluid temperature. Refer to the graphs below. Note 3) The response time until the set value reaches 9% in relation to the step input. Note 4) Refer to Wetted Parts Construction on page 4 for details. Flow-rate Characteristics (Pressure Loss) 7/5 7/5.4.4 Pressure loss [MPa].3.. Pressure loss [MPa] Flow rate [L/min] Flow rate [L/min] Straight Piping Length and ccuracy (Reference Value) Straight piping length 7/7/5/5 Pressure:.3 MPa Piping diameter: 5, 3 Fluid pressure has almost no effect. To maintain 3% F.S. in the specificatioins, use a straight pipe that is cm or longer in length. ccuracy [% F.S.] /5-U5 7/5-U3 (at L/min) (at 5 L/min) Straight piping length [cm] 3 For measurable range for ethylene glycol aqueous solution (reference values), refer to page 6.

17 3-color display Digital Flow Switch for PVC Piping Series Wetted Parts Construction q t w e r w t 3-Color Display Digital Flow Switch for Water Component Parts No. Description PVC pipe Seal 3 ody 4 Sensor Material CPVC FKM PPS PPS Note Replacement Parts No. Description PVC pipe (5) PVC pipe (3) 5 5 retaining plate (M5 x 8 with two hexagonal socket head cap screws) 3 retaining plate (M5 x 65 with two hexagonal socket head cap screws) Part no. ZS-4-U5 ZS-4-U3 ZS-4-U5- ZS-4-U3- Replacing the PVC pipe may cause accuracy to fluctuate by to %. Qty. Function Details 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 4

18 Series Dimensions 7-U5 Integrated display x 5 IN (35.5) OUT ø x Example 3 4 Connector pin number Pin no. 3 4 Pin name DC (+) OUT DC ( ) OUT 4 x 3.5 depth 4 5-U5 Remote sensor unit 6.6 IN OUT ZS-4- Lead wire with M8 connector (lack) 4 (lue) 3 M8 (White) (rown) Pin no. Pin name Wire color 3 4 DC (+) OUT DC ( ) OUT rown White lue lack 5 ø (3.8) ø4 (3) (45) (5) Lead Wire Specifications Conductor Insulator Sheath Finished O.D. Note ) 4-wire type lead wire with M8 connector used for the series. Note ) Refer to the Operation Manual in our website ( for wiring. Nominal cross section O.D. Material O.D. Color Material WG3 pprox..7 mm Heat resistant PVC pprox.. mm rown, White, lack, lue Heat and oil resistant PVC ø4

19 3-color display Digital Flow Switch for PVC Piping Series Dimensions 7-U3 Integrated display ody side Connector pin number x (35.5) Color Display Digital Flow Switch for Water Pin no. Pin name DC (+) OUT DC ( ) OUT 7.5 Flow direction 5 4 x 3.5 depth 4 ø38 3-Color Display Digital Flow Switch for PVC Piping 5-U3 Remote sensor unit ody side Connector pin number x (35.5) 3-Color Display Digital Flow Monitor for Water 3 Pin no. Pin name DC (+) Not used DC ( ) OUT Flow direction Function Details 6

20 Series Made to Order Please consult SMC for detailed dimensions,specifications and delivery. Made to Order Seal material EPDM Seal material for wetted parts changed to EPDM Symbol -X9 5 7 U U X9 X9 Seal material EPDM Refer to How to Order, page for details. 7

21 Digital Flow Monitor for Water Series Type Remote monitor unit For remote sensor units, select the analog output to 5 V type. pplicable sensors: 5--(T) Output specification Symbol OUT OUT C D E F G H nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m External input External input J K nalog to 5 V nalog 4 to m nalog to 5 V nalog 4 to m In combination with remote sensor unit with temperature sensor, only OUT can be set for temperature sensor output. Lead wire Nil With power supply/output connection lead wire ( m) Power supply/output connection lead wire ZS-4-W N Without power supply/output connection lead wire Lead wire is not connected, but shipped together. Options/Part No. 3-color display How to Order Remote monitor unit/unit specification Symbol Instantaneous flow rate ccumulated flow Temperature M G F J L/min gal/min gal/min L/min L gal gal L C C F F Under the New Measurement Law, units other than SI (symbol M ) cannot be used in Japan. Note) G, F, J: Made to Order Reference: [L/min].64 [gal/min] [gal/min] [L/min] F = 9/5C + 3 Calibration certificate (Only flow monitor) Nil None With calibration certificate The certificate is written in both English and Japanese. Option Nil C None Sensor connector ( pc.) Sensor connector (e-con) Connector is not connected, but shipped together. Option Nil When optional parts are required separately, use the following part numbers to place an order. Description Part no. Panel mount adapter ZS-6- Front protective cover + Panel mount adapter ZS-6-C Front protective cover only ZS-6- Power supply/output connection lead wire ZS-4-W Sensor connector (e-con) ZS-8-C-4 Lead wire with connector for copying ZS-4-Y M V C T V Waterproof seal (accessory) None Panel mount adapter Panel Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Front protective cover + Panel mount adapter Front protective cover Panel mount adapter Mounting screw (M3 x 8 L) (accessory) Waterproof seal (accessory) Panel Note With waterproof seal and screws With waterproof seal and screws Separately order panel mount adapter etc. Lead wire length ( m) pc. Connect up to slave units RoHS 8 3-Color Display Digital Flow Switch for Water 3-Color Display Digital Flow Switch for PVC Piping 3-Color Display Digital Flow Monitor for Water 3 Function Details

22 Series 3 Specifications Refer to Handling Precautions for SMC Products for Flow Switch Precautions and the Operation Manual in our website for Specific Product Precautions. Model Display flow range Set flow range Minimum setting unit Conversion of accumulated pulse Display unit ccuracy Repeatability Temperature characteristics ccumulated flow range Note ) Switch output Output Flow rate mode Temperature Response time Note 3) nalog output Voltage output Current output Hysteresis External input Input/output Display method Indicator light Power supply voltage Current consumption Connection Weight Maximum load current Maximum applied voltage Internal voltage drop Response time Note ) Output protection Enclosure Operating temperature range Environment Operating humidity range Withstand voltage Insulation resistance Standards and regulations Without power supply/output connection lead wire With power supply/output connection lead wire 3.35 to 4.5 L/min.7 to 8. L/min 3.5 to 45. L/min 7 to L/min to 8 L/min (Flow under.35 L/min is displayed as. ) (Flow under.7 L/min is displayed as. ) (Flow under 3.5 L/min is displayed as. ) (Flow under 7 L/min is displayed as ) (Flow under L/min is displayed as ).35 to 4.5 L/min.7 to 8. L/min 3.5 to 45. L/min 7 to L/min to 8 L/min. L/min. L/min L/min L/min.5 L/pulse. L/pulse.5 L/pulse L/pulse L/pulse Instantaneous flow rate: L/min, ccumulated flow: L Display value: ±.5% F.S. nalog output: ±.5% F.S. ±.5% F.S. ±.5% F.S. (5C reference) L L y. L y.5 L y L or open collector output 8 m 8 VDC : V or less (at 8 m load current) :.5 V or less (at 8 m load current) s/ s Short circuit protection Select from hysteresis mode, window comparator mode, accumulated output mode, or accumulated pulse output mode. Select from hysteresis mode or window comparator mode. s/ s (linked with the switch output) Voltage output: to 5 V Output impedance: k Output current: 4 to m Max. load impedance: 3 for VDC, 6 for 4 VDC Variable Voltage free input:.4 V or less (Reed or Solid state), input for 3 ms or longer Input for copy mode -screen display (Main screen: 4-digit, 7-segment, -color, Red/Green Sub screen: 6-digit, -segment, White), Display values updated 5 times per second Output, Output : Orange to 4 VDC % 5 m or less Power supply output 5P connector, sensor connection 4P connector (e-con) IP4 (Only front face of the panel is IP65 when panel mount adapter and waterproof seal of optional parts are used.) to 5C (with no freezing and condensation) Operation, Storage: 35 to 85% R.H. (with no condensation) VC for minute between terminals and housing 5 M or more (5 VDC measured via megohmmeter) between terminals and housing CE marking, UL (CS), RoHS 5 g g Note ) Cleared by turning off the power supply. It is possible to select the function to memorize it. (Every or 5 minutes) When 5 minutes memorizing is selected, the lifetime of the memory element (electronic part) is million times (5 minutes x million times = 5 million minutes = pprox. 9.5 years for 4 hour energizing). Calculate the lifetime based on your operating conditions before using the memorizing function, and do not exceed it. Note ) The response time when the set value is 9% in relation to the step input. (The response time is 7 s when it is output by the temperature sensor.) Note 3) The response time until the set value reaches 9% in relation to the step input. (The response time is 7 s when it is analog output by the temperature sensor.) Temperature Sensor Specifications Rated temperature range Setting/Display temperature range Minimum setting unit Display unit nalog output accuracy Response time mbient temperature characteristics 5% F.S. Note ) The rated temperature range is for the temperature sensor alone. The fluid temperature range specification of the flow switch as a whole is to 9C. Note ) The response time is for the temperature sensor alone. nalog Output Flow rate/nalog output C Output 4//4 C Voltage output V.5 V.4 V.5 V 5 V Current output 4 m 6 m 5.6 m 5.9 m m The values of vary according to the range. Model Flow rate [L/min] Minimum Maximum Minimum flow to C Note ) to C C C 3% F.S. 7 s Note ) Maximum Flow rate flow DC (+) rown Flow rate Remote to 5 V lack sensor Temperature to 5 V White unit DC ( ) lue The output related to the temperature sensor is OUT only. The OUT can be selected from the output for temperature or flow rate by button operation. Fluid temperature/nalog output Voltage output.6 V Current output.4 m V 4 m C D Voltage output 5 V 5.4 V Current output m.6 m e sure to use in combination with remote sensor unit with temperature sensor. Main circuit Output D C C Remote monitor unit C OUT Switch output nalog output OUT Switch output nalog output rown DC (+) lack OUT White OUT lue DC ( ) C C Fluid temperature

23 3-color display Digital Flow Switch for Water Series 3 Dimensions 4 Front protective cover + Panel mount adapter () 4. (7.5) NC/IN Sensor connector (4P) Power supply/ output connector (5P) 3-Color Display Digital Flow Switch for Water Panel fitting dimmensions pplicable panel thickness:.5 to 8 mm (Without waterproof seal).5 to 6 mm (With waterproof seal) 55 or more Front protective cover Waterproof seal x R or less Panel 48 or more Panel mount adapter 3-Color Display Digital Flow Switch for PVC Piping Sensor connector q w e r 3 4 Power supply/output connection lead wire Pin no. Gray COPY White OUT 3 lack OUT 4 lue DC ( ) 5 rown DC (+) Pin no. q w e r Terminal DC (+) N.C./IN DC ( ) INPUT Connector no. 3 4 Lead wire color rown White (Not used/temperature sensor to 5 V input) lue lack (Flow rate sensor to 5 V input) When using the lead wire with M8 connector included with the 5 series Lead Wire Specifications Nominal cross section Conductor O.D. Material Insulator O.D. Color Sheath Material Finished O.D. WG6 pprox..5 mm Cross-linked vinyl pprox.. mm rown, lue, lack, White, Gray Oil and heat resistant vinyl ø3.5 3-Color Display Digital Flow Monitor for Water 3 Function Details Note) Refer to the Operation Manual in our website ( for wiring.

24 Series Function Details Integrated Display (Series 7)/Remote Monitor Unit (Series 3) Output operation The output operation can be selected from the following: Output (hysteresis mode and window comparator mode) corresponding to instantaneous flow rate, Output corresponding to accumulated flow, ccumulated pulse output Note) t the time of shipment from the factory, it is set to hysteresis mode and normal output. When a temperature sensor is attached, the output to the temperature sensor is selectable only for OUT. (Refer to How to Order for details.) Indication color The indication color can be selected for each output condition. The selection of the indication color provides visual identification of abnormal values. (The indication color depends on OUT setting.) ON: Green, OFF: Red ON: Red, OFF: Green lways: Red lways: Green Response time The response time can be selected depending on the application. ( second for default setting) bnormalities can be detected more quickly by setting the response time to.5 seconds. The effect of the pump fluctuation and flickering of the display can be reduced by setting the response time to seconds. Note) The temperature sensor output is fixed to 7 seconds. Response time.5 seconds second seconds pplicable model Integrated display Remote monitor unit Series 7 Series 3 Selection of display on sub screen The display on the sub screen in measuring mode can be set. External input function This function can be used when external input is available. The accumulated value, peak value, and bottom value can be reset by remote control. ccumulated flow external reset: This function resets the accumulated value to when an input signal is applied. In accumulated increment mode, the value will be zero when reset, and the accumulated value will increase from zero. In accumulated decrement mode, the value will be the set value when reset, and the accumulated value will decrease from the set value. When the accumulated value is memorized, every time the accumulated value external reset is activated, the memory element (EEPROM) will be accessed. Take into consideration the maximum number of times the memory element can be accessed, million times. The total of external input times and accumulated value memorizing time interval should not exceed million times. Peak and bottom reset: Peak and bottom values are reset. Forced output function Output is turned ON/OFF compulsorily when starting the system or during maintenance. This enables confirmation of the wiring and prevents system errors due to unexpected output. For the analog output type, the output will be 5 V or m for ON and V or 4 m for OFF. lso, the increase or decrease of the flow and temperature will not change the on/off status of the output while the forced output function is activated. ccumulated value hold function ccumulated value can be saved on the unit even when the power supply is turned off. The accumulated value is memorized every or 5 minutes during measurement, and continues from the last memorized value when the power supply is turned on again. The lifetime of the memory element is million access cycles. Take this into consideration before using this function. Sub screen Displays the set value. (The set value of OUT cannot be displayed.) Integrated display Displays the accumulated value. (The accumulated value of OUT cannot be displayed.) Remote monitor unit Set value display ccumulated value display Peak value display ottom value display Displays the peak value. Displays the bottom value. Line name display Displays the line name. (Up to 6 alphanumeric characters can be input.) Fluid temperature display Displays the fluid temperature. (When the temperature sensor type is selected.) OFF Displays nothing. The above are examples of integrated displays. (Same as remote monitor unit) Power saving mode The display can be turned off to reduce the power consumption. In power saving mode, decimal points blink on the main screen. If any button is pressed during power saving mode, the display is recovered for 3 seconds to check the flow, etc. Setting of secret code Users can select whether a secret code must be entered to release key lock. t the time of shipment from the factory, it is set such that the secret code is not required. Peak/ottom value indication The maximum (minimum) flow is detected and updated from when the power supply is turned on. In peak (bottom) value indication mode, this maximum (minimum) flow is displayed. Keylock function Prevents operation errors such as accidentally changing setting values.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

LCD Readout Digital Pressure Switch

LCD Readout Digital Pressure Switch LCD Readout Digital Pressure Switch Series ZSE3 (For )/E3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display RoHS Can be integrated with a vacuum unit, Series

More information

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.

2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar. CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension

More information

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100. Precision Regulator Series // Basic Type Air Operated Type Series Model Regulating pressure range Page Series Series Series Series Series.5 to MPa. to MPa. to.8 MPa /8 55.5 to MPa. to MPa /4 55. to.8 MPa.

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and

More information

ISE4. Series ZSE4. Digital Pressure Switch. LCD Readout. (For vacuum) (For positive pressure) For General Pneumatics

ISE4. Series ZSE4. Digital Pressure Switch. LCD Readout. (For vacuum) (For positive pressure) For General Pneumatics Choice of display units Display units can be easily selected and changed, making these switches globaly acceptable. LCD Readout Digital Pressure Switch Series (For vacuum) (For positive pressure) Vacuum

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51 DC Input BLH Series Brushless DC Motors Intro duction BLF BLU BLH Installation C Input DC Input Page BLH Series B-52 B-51 RoHS-Compliant Brushless DC Motor and Package BLH Series The BLH Series combines

More information

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics

More information

Givare NC-SRS 280 och 880

Givare NC-SRS 280 och 880 Givare NC-SRS 280 och 880 Aratron AB/Nordic Control, 02 03 SRS280SEALED ROTARY SENSOR PERFORMANCE ±2 Resistance ±20% Hysteresis (repeatability) Accuracy Applied voltage maximum Resolution Output smoothness

More information

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version Electronic pressure measurement Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version WIKA data sheet PE 81.66 Applications Machine building

More information

VSO MAX HP High Flow Proportional Valve

VSO MAX HP High Flow Proportional Valve VSO MAX HP High Flow Proportional Valve Typical Applications Ventilators Insufflators Anesthesia Delivery & Monitors Pressure & Flow Control Mass Flow Control Product Specifications Physical Properties

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00.

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS3115-01 VS3115-02 VS3110-02 VS3110-03 VS3114-00. Port Direct Operated Solenoid Valve Series VS5/0 Metal Seal Multiple pressure supply is possible with balanced spool sleeve. Any given port can accept high or low pressure supply without affecting the

More information

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB100-0100 WaterMAG Electromagnetic Flowmeter for Water Applications OVERVIEW The WaterMAG is an electromagnetic flowmeter for water measurement applications based on field proven Azbil Corporation's technologies.

More information

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S. Electro-Pneumatic Proportional Valve Series /VEP Electro-pneumatic proportional valve: Flow type () Controls the flow rate steplessly according to current. (It is a / port valve that has an electrical

More information

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval

SSC-T800series. New type with radial cross ray method. Light Curtain Sensors. Type. Radial Cross Ray Method. Detecting width. Light axis interval series Light Curtain Sensors New type with radial cross ray method Small objects and flat tape-like objects detected Convenient simplified wiring requiring no clock (synchronization) line Compact and flat

More information

3 Port Solenoid Valve

3 Port Solenoid Valve Port Solenoid Valve Series V00 Rubber Seal Power consumption 0. W (with power saving circuit) VV0 VV00 V00 -V F VS temperature rises: C (with power saving circuit) Sonic conductance Series Standard Large

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89]

Specifications - Installation and Operating Instructions Ø5 [127.00] 17/64 [6.91] 1-59/64 [48.89] Bulletin P-DM-1100 Series DM-1000 DigiMag Digital Differential Pressure Gage Specifications - Installation and Operating Instructions PRESSURE CONNECTIONS 21/64 [8.59] LONG Ø5 [127.00] 4-31/64 [113.89]

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 Data Sheet Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43 2-Wire Operation Significantly reduces installation costs when compared to a traditional 4-wire magmeter. ±0.5% of rate system accuracy. Patented

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Electronic Pressure Switch EDS 3000

Electronic Pressure Switch EDS 3000 For Your Information Electronic Pressure Switch EDS 3000 User Manual Revision: November 01, 2002 1. EDS 3000 Functions The EDS 3000 unit offers the following functions: Display pressure in psi, MPa, or

More information

Series DFMT Digital Paddlewheel Flowmeter

Series DFMT Digital Paddlewheel Flowmeter Series DFMT Digital Paddlewheel Flowmeter Bulletin F-DFMT Specifications - Installation Operating Instructions -/8 [00] -/ [8] -/8 [00] A The Series DFMT Digital Paddlewheel Flow Transmitter provides instantaneous

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

OPL BASIC. Dosing System for Professional Laundry machines. Contents

OPL BASIC. Dosing System for Professional Laundry machines. Contents OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page

More information

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics THORTO Leading Pure Water nalytics Economical Paddlewheel Hi-Purity PF Ultrasonic Vortex Insertion-type Vortex Convenient, Reliable and Economical Flow Measurement Paddlewheel Reliable and Economical Inline

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

PIEZOMETER AIRFLOW MEASURING RING

PIEZOMETER AIRFLOW MEASURING RING PIEZOMETER AIRFLOW MEASURING RING M.K. Plastics is pleased to introduce The Piezometer Airflow Measuring Ring, now available as an accessory for our steel Axijet fans. The system consists of a Piezometer

More information

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

Series 427. 1/16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS Series 427 1/16 DIN Multi-Mode Bar Graph Display Timer PRODUCT HIGHLIGHTS Digital Setting with 0.1% Accuracy Unique LED Bargraph Indicates Time Cycle in 20% Increments 8 Field Selectable Modes of Operation

More information

COMBIMASS. Technical Data COMBIMASS eco-bio +

COMBIMASS. Technical Data COMBIMASS eco-bio + COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Solid State Timers Type F

Solid State Timers Type F Solid State Timers Type F Class 9050 CATALOG CONTENTS Description.....................................................Page Product Descriptions............................................. 3 Application

More information

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7. Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

Typical Aluminum GFM Mass Flow Meter

Typical Aluminum GFM Mass Flow Meter MASS FLOW METERS Design Features n Rigid metallic construction. n Maximum pressure of 1000 psig (70 bars). n Leak integrity 1 x 10-9 of helium. n NIST traceable certification. n Built-in tiltable LCD readout.

More information

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973 Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output. Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling

More information

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011

Operating instructions Mechatronic flow sensor. SBY33x 704465/06 03/2011 Operating instructions Mechatronic flow sensor SBY33x 7065/06 03/2011 Contents 1 Safety instructions...2 2 Functions and features...3 3 Installation...3 Electrical connection... 5 Switch point setting...

More information

TMS TANK MANAGEMENT SYSTEM

TMS TANK MANAGEMENT SYSTEM TMS TANK MANAGEMENT SYSTEM Page 1 of 9 Operating Instructions GENERAL The Tank Management System is a bespoke design to control, monitor and accommodate efficient storage and dispensing of TMS. FUNCTIONS

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

3/2- and 2/2-way cartridge valve type BVE

3/2- and 2/2-way cartridge valve type BVE 3/2- and 2/2-way cartridge valve type BVE for any flow direction, zero leakage, all ports pressure resistant Flow Q max = 70 lpm Perm. pressure p max = 400 bar Additional valves with same function: ' Type

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394

Druck DPI 104. GE Industrial Sensing. Digital pressure indicator User manual - K394 GE Industrial Sensing 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com Druck DPI 104 Digital pressure indicator User manual - K394 A1.1 A1.2 B1 1 A2 B2 2 3 4 5 6 A1.3 8 7

More information

3 Port Solenoid Valve

3 Port Solenoid Valve ubber Seal ort Solenoid Valve Series SYJ00/00/700 [Option] SYJ VQZ V VG Improved pilot valve ilot valve cover is stronger using stainless steel. Mounting thread is also reinforced from size M1.7 to M.

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding

More information

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS 40.1001 401001/000-459-405-502-20-601-61 Produktdatenblatt - JUMO MIDAS Pressure Transmitter JUMO AS Street address: Solheimveien 50, 1470 Lørenskog, Norway Phone: +47 67 97 37 10 Delivery address: Solheimveien 50, 1470 Lørenskog, Norway Fax:

More information

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant

More information

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications

Universal type. Elbow type AS13 1FG-M5 AS23 1FG-01 AS23 1FG-02 AS33 1FG-02 AS33 1FG-03 AS43 1FG-04. Specifications Speed Controller with One-touch Fitting Stainless Steel Series Elbow Type/Universal Type Series -FG RoHS Stainless specifications for use in corrosive environments. Stainless steel used for metal parts.

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

=============================== WARNING

=============================== WARNING =============================== WARNING EXPLANATION OF GRAPHICAL SYMBOLS This symbol is intended to alert the user to the presence of unprotected dangerous voltage" within the product's enclosure that

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Instruction Manual. T3111 T3111L T3111P T3111Ex

Instruction Manual. T3111 T3111L T3111P T3111Ex www.cometsystem.cz Instruction Manual T3111 T3111L T3111P T3111Ex Programmable transmitter of temperature, relative humidity and other calculated humidity values with external probe and 4-20 ma outputs

More information

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

0.35 0.9. 3 Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3 Port Solenoid Valve 00/00/00 Metal Seal Rubber Seal 0. 0.9 (Standard) (High pressure type, High speed response type) Power consumption: 0. W/0.9 W Compact, High Flow Body ported Base mounted 00 00 00 00

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art. 119914 631001A COOLING or HEATING ANALOG or PWM Art. 119914 631001A TOTAL AUTOMATION GENERAL TRADING CO. LLC SUITE NO.506, LE SOLARIUM OFFICE TOWER, SILICON OASIS, DUBAI. UAE. Tel. +971 4 392 6860, Fax. +971 4 392 6850

More information

2 Window comparator mode. Hysteresis Hysteresis

2 Window comparator mode. Hysteresis Hysteresis SERIES High-performance Digital Pressure Sensor Digital Automatic sensitivity setting With analog output Complete functionality! Selection from a wide lineup DP3 * UL 61010C-1 compatible, Passed the UL

More information

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate 1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration

More information

FAQ s on Siemens Magmeters

FAQ s on Siemens Magmeters FAQ s on Siemens Magmeters 1. The cables for the coils and electrodes for the magmeters look the same. Does it matter which cable is used for coils and which one is used for the electrodes? Both cables

More information

Technical data. Danfoss DHP-A

Technical data. Danfoss DHP-A Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

Incremental Rotary Encoder E6B2

Incremental Rotary Encoder E6B2 Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function

More information

Series 510 Submersible Level Transmitters

Series 510 Submersible Level Transmitters Series 510 Submersible Level Transmitters The Series 510 Submersible Level Transmitters are solid state instruments designed for direct submergence into many types of liquid for quick, accurate and reliable

More information

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service

More information

In-Sight Hardware specifications

In-Sight Hardware specifications specifications In-Sight 5000, 5100, 5400, 5400S, 5400C, 5401, and 5403 4020 Linz/Austria Pummererstr. 36 Tel.: +43-(0)70-7646-0* www.schmachtl.at Memory Job/Program 16MB non-volatile flash memory; Unlimited

More information

QR12 (1.22 ) Diameter Optical Encoder

QR12 (1.22 ) Diameter Optical Encoder Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

T5000 T000 LCD Digital Fan Coil Thermostat

T5000 T000 LCD Digital Fan Coil Thermostat T5000 T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostat T000 LCD Digital Fan Coil Thermostats are designed to control heating, cooling, or year round air conditioning unit in Commercial,

More information

Absolute Rotary Encoder E6CP

Absolute Rotary Encoder E6CP Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the

More information

Electronic Pressure Switch EDS 300

Electronic Pressure Switch EDS 300 Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5

More information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 www.atos.com Table F040-1/E Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32 AGMZO are two stage poppet type proportional

More information

Explosion proof enclosures

Explosion proof enclosures 1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without

More information

Solenoid valves 2/2-way direct-operated Type EV210A

Solenoid valves 2/2-way direct-operated Type EV210A Solenoid valves 2/2-way direct-operated Type EV210A Features EV210A NC and NO Very compact valves for industrial application, such as control and dosage For water, oil, compressed air and similar neutral

More information

SPEED CONTROL SYSTEM

SPEED CONTROL SYSTEM SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

T0118 T2118 T3118. Instruction Manual

T0118 T2118 T3118. Instruction Manual Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features Features Applications The PMP 4000 Series provides a complete range of high level voltage output pressure transducers offering advanced levels of measurement accuracy, stability and flexibility from a

More information