OLS-2100 Occupancy Light Switch



Similar documents
TE-6300P Series Temperature Sensors

T25 Two-Stage Room Thermostat

Product/Technical Bulletin

VG7000 Series Bronze Control Valves

System 350 A350A/B Electronic Temperature Control

HE-6800 Series Humidity Transmitters with Temperature Sensor

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

P266 Series Single-Phase Condenser Fan Speed Controls

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

P499 Series Electronic Pressure Transducers

INSTALLATION INSTRUCTION Touch Panel Switch with Occupancy Sensor

CST29A Adapter Block for Carlyle Compressors

M9220-HGx-3 Proportional Electric Spring Return Actuators

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

G670 Intermittent Pilot Ignition Controls

LOS 2500 SUPER CEILING SENSOR. Installation Manual

EBDSPIR-PRM, EBDSPIR-PRM-IP

Model SRMD Setra Remote Monitoring Display

T and T Single Input Receiver-Controllers Installation and Calibration

A99B Series Temperature Sensors

Installation Instructions

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Y7230A CO 2 Alarm System

LED Security Spotlight User Manual

P70, P72, and P170 Series Controls for Dual Pressure Applications

Leak Detection System

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

ADM1TE 5/30A DIN rail single phase two wire energy meter

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

T5000 T000 LCD Digital Fan Coil Thermostat

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

TS93 EMR T/PT/TDE. Surface applied door closer

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

High Bay Occupancy Sensor Selection Guide

LED MOTION ACTIVATED FLOOD LIGHT

WD-AMX Water Detection Controllers

P66 Series Electronic Fan Speed Controls

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Portable BACnet /IP to MS/TP Router

T7560A,B,C Digital Wall Module

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

767 Diagnostic System

Lumination TM LED Luminaires Light Bar Retrofit Kit Series

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

A-4000 Oil Indicator

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

LED MOTION ACTIVATED FLOOD LIGHT

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

Die-Cast Metal, Motion- Activated Post Light

Modular Room Control (MRC) Series Digital Thermostat

System 350 A350R Electronic Temperature Reset Control (with Relay)

MCR1900 Media Converter 19-Slot Chassis

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

±15 V Current-Limited Power Supply

INSTALLATION INSTRUCTIONS

INSTALLER S & OWNER S MANUAL

System 350 A350E Electronic Cooling Control

WARNING CANADIAN D.O.C. WARNING

esata External Storage

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Refer installation of power supplies to qualified service personnel.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

HP UPS R1500 Generation 3

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

Dual Technology Ceiling Mount Sensor

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

INSTALLATION GUIDE 1

Applied Electronics. Commercial Dimming System UPDATE NOTICE

VG2000 Series Cast Iron Flanged Globe Valves

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054

! WARNING. Before using product, read and understand instructions.

Operator: Save these instructions for future use!

Advantium 2 Plus Alarm

Operating Instructions

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

5-Slot Housing and FrameSaver 9000 Series Access Carrier AC Power Supply Installation Instructions

Stove Guard Kit User Manual

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

T7079A,B Solid State Remote Temperature Controllers

COLOR VIDEO DOOR PHONE CDV-71BE/D

, User s Manual

Drayton Digistat +2RF/+3RF

Home Security Alarm System

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Operating Instructions

CELO5. User & Installation Manual.

MP8000 Series Pneumatic Valve Actuators

Radiant Temperature Sensor TY7321

Digital Keypad Use s Manual

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Transcription:

OLS-2100 Occupancy Light Switch Product/Technical Bulletin OLS-2100-1 24-7691- 25, Rev. E Part No. 24-7691-25, Rev. E Code No. LIT-216270 Issued March 2016 The OLS-2100 Occupancy Lighting Switch is a passive infrared sensor that turns lights on when occupancy is detected and off when the area is empty. Three adjustments are available light level, time delay, and sensitivity level allowing for changes that best match the room s use and the occupant s needs. Lighting is a large part of a typical commercial building s energy consumption, accounting for 40% of the electricity used. Whether used as standalone lighting control or as part of an existing lighting system, the OLS-2100 switch helps reduce energy costs. Refer to the QuickLIT website for the most up-to-date version of this document. Figure 1: OLS-2100 Occupancy Lighting Switch Table 1: Features and Benefits Features Standard, Single-toggle Switch Size Benefits Allows quick and easy replacement of existing wall switches, reducing installation time. Infrared Occupancy Sensor Controls lighting usage based on occupancy. 120/277 VAC (60 Hz Only) Model Provides compatibility with supply voltages in most commercial buildings. Low-profile Design Complements any building or office decor. 180 Field of View: Coverage to 900 sq ft Covers most typical offices, conference rooms, and storage areas. (81 sq m) Adjustment Cover with Anti-tampering Feature Prevents unauthorized changes to selected settings. OLS-2100 Occupancy Light Switch Product/Technical Bulletin 1

FIG:OLS2000_rm_cvrg_pttrn Application IMPORTANT: Use this OLS-2100 Occupancy Lighting Switch only as an operating control. Where failure or malfunction of the OLS-2100 Switch could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the OLS-2100 Switch. IMPORTANT: Utiliser ce OLS-2100 Occupancy Lighting Switch uniquement en tant que dispositif de régulation. Lorsqu'une défaillance ou un dysfonctionnement du OLS-2100 Switch risque de provoquer des blessures ou d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du OLS-2100 Switch. The OLS-2100 Occupancy Lighting Switch is a passive infrared sensor that turns lights on when occupant movement is detected within its field of view. The OLS-2100 switch replaces standard single-pole light switches that control incandescent or fluorescent fixtures with either magnetic or electronic ballasts. The switch is an indoor lighting control and should not be used outdoors or as a security device. Mounting Install the OLS-2100 switch 3.5 to 4.5 feet (1.1 to 1.4 m) above the floor, with an unobstructed view of the work or traffic area to be monitored. The OLS-2100 switch has a 180 field of view (900 sq ft [81 sq m)]) Figure 3: OLS-2100 Room Coverage Patterns Avoid locating the switch in the following areas: in direct sunlight or near bright lights near intense heat or moisture sources where movement in adjacent areas could unintentionally turn the lights on Wiring! WARNING: Risk of Electric Shock. Disconnect the power supply before making electrical connections. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. WARNING: Risk of décharge électrique. Débrancher l'alimentation avant de réaliser tout branchement électrique. Tout contact avec des composants porteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. FIG:OLS2000_dim Figure 2: OLS-2100 Dimensions (in./mm) 2 OLS-2100 Occupancy Light Switch Product/Technical Bulletin

FIG:adjstmnts_nocvr! WARNING: Risk of Property Damage. Do not apply power to the system before checking all wiring connections. Short circuited or improperly connected wires may result in permanent damage to the equipment. CAUTION: Risk of dégâts matériels. Ne pas mettre le système sous tension avant d'avoir vérifié tous les raccords de câblage. Des fils formant un court-circuit ou connectés de façon incorrecte risquent d'endommager irrémédiablement l'équipement. 1. Check that the combined load connected to the OLS-2100 switch is within the load range listed in Table 3. 2. Remove the existing wall plate and switch. 3. Press the OFF/AUTO button to the OFF position. (Button out.) 4. Wire the OLS-2100 as shown in Figure 4. Setup and Adjustments Wait 2 minutes after power is applied before making any adjustments. All adjustments are factory set to their maximum settings. Maximum is fully clockwise; minimum is fully counterclockwise. IMPORTANT: Do not turn the adjustment screws past their limits. The adjustment screws can be damaged by exceeding their limits. IMPORTANT: Touch the metal frame around the unit before removing the cover. When a wall plate is not installed, the unit may be damaged by static electricity. Pull the cover surrounding the OFF/AUTO button straight off to access the adjustment screws. Use a small screwdriver to turn the adjustment screws to the desired settings. (See Figure 5.) FIG: DLS2000_wrng Figure 5: Location of Adjustments with Cover Removed Figure 4: OLS-2100 Wiring Diagram Note: Use the termination on the green wire and the mounting screw (provided) for grounding to a continuous grounding system. 5. Install the OLS-2100 switch in the utility box using the two flat-head screws provided. The OLS-2100 switch fits into a standard, 2 in. x 4 in. (51 mm x 102 mm) utility box with a minimum depth of 1-7/8 in. (48 mm). 6. Apply power. 7. Press the OFF/AUTO switch to AUTO (button in). The lights turn on within 10 seconds. The following adjustments are available: Sensitivity: Controls the sensor s ability to detect motion, from less sensitive (minimum counterclockwise setting) to very sensitive (maximum clockwise setting). The maximum setting covers the entire 180 field of view. At the minimum setting, the sensor requires greater motions at closer distances to turn the lights on. The maximum setting is recommended. Note: The red LED blinks when the sensor detects motion. Daylight Lockout: Prevents lights from turning on when adequate levels of natural light are available. Wait to set the daylight lockout until the natural light level is sufficient for work or traffic. Then, to enable daylight lockout, use the following steps: a. Check that the OFF/AUTO switch is in the AUTO position (button in). OLS-2100 Occupancy Light Switch Product/Technical Bulletin 3

b. Turn the daylight lockout adjustment screw completely counterclockwise. c. Turn the time delay adjustment screw completely counterclockwise. d. Remain motionless until the lights turn off (approximately 30 seconds). Do not cast a shadow in front of the sensor, as this movement turns the lights on. e. Turn the daylight lockout adjustment screw slowly clockwise until the lights turn on. Then, turn the screw slightly back towards minimum. f. Reset the delay time control if necessary. Time Delay: Controls the length of time between the last sensed movement and when the lights are turned off, from 30 seconds (minimum) to 30 minutes (maximum). A quarter turn counterclockwise is equal to 15 minutes. The maximum clockwise setting (30 minutes) is recommended. When finished making adjustments, snap the cover back into place. Place the wall plate over the sensor and attach with two screws. Remove the blue OFF/AUTO override jumper pin (Figure 5) to make the OLS-2100 switch function like a standard ON/OFF switch. After removing the jumper, press the AUTO/OFF switch to turn lights on or off. Troubleshooting Table 2: Troubleshooting Problem Possible Solutions Unit does not function or LED does not flash (LED normally flashes when the sensor detects motion) Unit picks up movements outside the desired area to be monitored Ordering Information 1. Pull out the blue jumper (see Figure 5) to make the unit function as a regular ON/OFF switch. 2. Press the OFF/AUTO button. 3. If the lights still do not come on, verify that the ground connection is good. 4. If the unit still does not work, replace it. Limit the detection area by placing a strip of opaque adhesive tape (included with unit) over the part of the lens that views the area to be excluded. Adjust the sensitivity control counterclockwise to reduce sensitivity. To order the OLS-2100 from your local Johnson Controls branch or wholesale distributor, specify the complete model code number and quantity. Table 3: Selection Product Code Number Voltage (VAC) 1 Lighting Type Load Range Limits (Watts) OLS-2100-1 120 VAC, 60 Hz Incandescent 25 to 800 Fluorescent 40 to 800 277 VAC, 60 Hz Fluorescent only 40 to 1,200 1. This model does not operate at 50 Hz. 4 OLS-2100 Occupancy Light Switch Product/Technical Bulletin

Technical Specifications OLS-2100 Occupancy Light Switch Sensor Type Power Requirement Load Range Passive infrared 120/277 VAC, 60 Hz (Standard or electronic ballast) 120 VAC, 60 Hz; 25 to 800 watts incandescent, 40 to 800 watts fluorescent 277 VAC, 60 Hz; 40 to 1,200 watts fluorescent Current Consumption Less than 0.5 ma Warmup Time 60 seconds maximum Wiring 3-wire installation (Requires a continuous grounding system.) Ambient Conditions 32 to 95 F (0 to 35 C), 5 to 95% RH noncondensing; 85 F (29 C) maximum dew point Field of View 180 (900 sq ft [81 sq m]) LED Indicator Flashes when motion is detected Daylight Lockout Control Lights stay off if adequate light level is detected Time Delay Control 30 seconds to 30 minutes (Factory set to 30 minutes.) Sensitivity Control Adjustable from 20 to 100% of maximum sensitivity. (Factory set to 100%.) Shipping Weight 0.5 lb (0.23 kg) Agency Listing UL Listed (120 VAC and 277 VAC models), cul Listed (120 VAC) The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: WESTENDHOF 3 45143 ESSEN GERMANY 507 E MICHIGAN ST MILWAUKEE WI 53202 USA C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2016 Johnson Controls, Inc. OLS-2100 Occupancy Light Switch Product/Technical Bulletin 5 Published in U.S.A. www.johnsoncontrols.com