Applications of confocal fluorescence microscopy in biological sciences



Similar documents
Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

Confocal Microscopy and Atomic Force Microscopy (AFM) A very brief primer...

Fluorescence Microscopy for an NMR- Biosensor Project

Neuro imaging: looking with lasers in the brain

Microscopy: Principles and Advances

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Two-photon FCS Tutorial. Berland Lab Department of Physics Emory University

Measuring the Point Spread Function of a Fluorescence Microscope

Molecular Spectroscopy

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Chapter 4. Microscopy, Staining, and Classification. Lecture prepared by Mindy Miller-Kittrell North Carolina State University

Near-field scanning optical microscopy (SNOM)

Microscopy. MICROSCOPY Light Electron Tunnelling Atomic Force RESOLVE: => INCREASE CONTRAST BIODIVERSITY I BIOL1051 MAJOR FUNCTIONS OF MICROSCOPES

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Zeiss 780 Training Notes

Chapter 13 Confocal Laser Scanning Microscopy C. Robert Bagnell, Jr., Ph.D., 2012

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Introduction to flow cytometry

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Synthetic Sensing: Proximity / Distance Sensors

Flow cytometry basics fluidics, optics, electronics...

Taking the Confusion out of Confocal Microscopy

Optical laser beam scanner lens relay system

Basic principles and mechanisms of NSOM; Different scanning modes and systems of NSOM; General applications and advantages of NSOM.

Physics 441/2: Transmission Electron Microscope

Introduction to Flow Cytometry

5. Scanning Near-Field Optical Microscopy 5.1. Resolution of conventional optical microscopy

PHYSICAL METHODS, INSTRUMENTS AND MEASUREMENTS Vol. IV Femtosecond Measurements Combined With Near-Field Optical Microscopy - Artyom A.

Introduction to microstructure

Optical mesoscopy with a new giant lens. Gail McConnell, Johanna Tragardh, John Dempster & Brad Amos

Lenses and Apertures of A TEM

CREOL, College of Optics & Photonics, University of Central Florida

Z-Stacking and Z-Projection using a Scaffold-based 3D Cell Culture Model

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Biomedical & X-ray Physics Kjell Carlsson. Light Microscopy. Compendium compiled for course SK2500, Physics of Biomedical Microscopy.

- thus, the total number of atoms per second that absorb a photon is

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Optical Coherence Tomography OCT. 3D Imaging in Medical Technology and Quality Control

It has long been a goal to achieve higher spatial resolution in optical imaging and

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Flow Cytometry A Basic Overview

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Recording the Instrument Response Function of a Multiphoton FLIM System

Bio 321 Lightmicroscopy Electronmicrosopy Image Processing

Super Resolution Optical Microscopy. Bo Huang

Raman Spectroscopy Basics

Lecture 1: Basic Concepts on Absorption and Fluorescence

RAY TRACING UNIFIED FIELD TRACING

A Brief History of the Microscope and its Significance in the Advancement of Biology and Medicine

Acousto-optic modulator

ID Objective Requirements Description of Test Date & Examiner 15 Verify that the optics?? OMC

THE COMPOUND MICROSCOPE

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

A pretty picture, or a measurement? Retinal Imaging

Observing a nanomachine at work: Single-molecule imaging or spectroscopy (SMI or SMS)

Biomedical Optics Theory

EXPERIMENT #1: MICROSCOPY

FRET Basics and Applications an EAMNET teaching module

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fiber Optic Tweezers and Optical Stretcher: biophotonic tools for single cell studies

Alignement of a ring cavity laser

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Crystal Optics of Visible Light

A Guide to Acousto-Optic Modulators

3D TOPOGRAPHY & IMAGE OVERLAY OF PRINTED CIRCUIT BOARD ASSEMBLY

Laser expander design of highly efficient Blu-ray disc pickup head

Lecture 3: Optical Properties of Bulk and Nano. 5 nm

These particles have something in common

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

Advances in scmos Camera Technology Benefit Bio Research

A Decade of Super-Resolution Innovation

Raman spectroscopy Lecture

Principles of Microscopy and Confocal and Fluorescence Microscopy

Laser Diode Gas Sensors

Subject Area(s) Biology. Associated Unit Engineering Nature: DNA Visualization and Manipulation. Associated Lesson Imaging the DNA Structure

The Olympus stereology system. The Computer Assisted Stereological Toolbox

Single Photon Counting Module COUNT -Series

Understanding Laser Beam Parameters Leads to Better System Performance and Can Save Money

Short overview of TEUFEL-project

Microsecond Decay FLIM: Combined Fluorescence and Phosphorescence Lifetime Imaging

NEAR FIELD OPTICAL MICROSCOPY AND SPECTROSCOPY WITH STM AND AFM PROBES

Optical Communications

Nanoscale Resolution Options for Optical Localization Techniques. C. Boit TU Berlin Chair of Semiconductor Devices

A More Efficient Way to De-shelve 137 Ba +

Single Defect Center Scanning Near-Field Optical Microscopy on Graphene

Confocal Microscopy. Chapter 2

Experiment 5. Lasers and laser mode structure

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

View of ΣIGMA TM (Ref. 1)

Preface Light Microscopy X-ray Diffraction Methods

THE IMPOSSIBLE DOSE HOW CAN SOMETHING SIMPLE BE SO COMPLEX? Lars Hode

UNIVERSITY OF WROCŁAW

MITOSIS IN ONION ROOT TIP CELLS: AN INTRODUCTION TO LIGHT MICROSCOPY

BIOMEDICAL ULTRASOUND

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Particle Size Analysis

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Physics 10. Lecture 29A. "There are two ways of spreading light: to be the candle or the mirror that reflects it." --Edith Wharton

Transcription:

Applications of confocal fluorescence microscopy in biological sciences B R Boruah Department of Physics IIT Guwahati Email: brboruah@iitg.ac.in Page 1

Contents Introduction Optical resolution Optical sectioning with a laser scanning confocal microscope Confocal fluorescence imaging Stimulated emission depletion (STED) microscopy Fluorescence resonance energy transfer (FRET) Fluorescence lifetime imaging Two photon excitation microscopy Conclusion Page 2

A simple microscope Reflected light image Detection lens Z X object Diffraction limited illumination volume Point source Beam splitter Collimated beam of wavelength λ is focused by L1 to a diffraction limited volume The illumination volume depends on λ, focal length and diameter of the illumination lens A point object is imaged into a diffraction limited volume in the image space Illumination lens X Z Page 3

Resolution of a microscope Object image Z X point object and the corresponding image two object points in the lateral direction whose images are just resolved two object points are indistinguishable in the image two object points in the axial direction whose images are just resolved Resolution: minimum separation between two point objects whose images are just resolved Contributions from diffractions due to the illumination and detection lenses Axial resolution is worse than lateral resolution Page 4

Optical sectioning with a confocal microscope detector pin hole detector pin hole detection lens Sample plane Focal point Sample plane Laser beam Laser beam Illumination lens Confocal arrangement of focal point and pinhole blocks light from out of focus planes or points away from the optic axis The detector receives light mostly from the focal point Image, free of out of focus blur, of a point object located at the focal point Page 5

Optical sectioning with a confocal microscope detector PC BS scan Wide field image Confocal image (Source :www.olympusfluoview.com) Either the sample holding stage or the illumination spot is scanned Scanning is controlled by a PC For each object point at the illumination spot, the detector signal is stored in the PC Results in an optically sectioned image (image corresponds to a sharply defined object plane, devoid of out of focus blur) of the sample Much better axial and marginally better lateral resolutions than a conventional (wide field) microscope Best resolution: lateral=~λ/2, axial=~λ Page 6

A beam scanning confocal setup detector pinhole Laser Scanner unit Beam splitter scanner 4f system Objective lens target X scan mirror Y scan mirror Page 7

Confocal fluorescence microscope vibrational relaxation S 1 emission filter excitation beam dichroic beam splitter (DBS) Excitation (λ EXC ) Fluorescence (λ EM ) detector fluorescence scan S 0 Molecules (fluorophores) are excited with a laser beam of wavelength (λ EXC ), which than undergo a series of spontaneous emissions called fluorescence at the mean wavelength (λ EM ) DBS: reflects λ EXC and transmits λ EM Emission filter : blocks reflected light from the sample at λ EXC Page 8

Confocal fluorescence imaging The target molecules are tagged with fluorescent probes or fluorophores Confocal detection of the fluorescent light in a beam scanning or stage scanning set up Fluorescence image provides information about the physical and Confocal fluorescence image of human T cells (source: PhD thesis, B R Boruah) chemical environment and orientation of the fluorophores and hence of the attached target molecules Best resolution working in the UV-visible range (lateral >200 nm, axial >500 nm) Not enough for visualising light-matter interaction at nanoscale Page 9

Confocal fluorescence imaging HEK293 cells stained with Di-4-ANEPPDHQ, a membrane specific and lipid activated fluorophore, which orients in the membrane,normal to the surface X 532nm illumination, 60x 1.2NA olympus water immersion lens Y (source: PhD thesis, B R Boruah) Page 10

Confocal fluorescence imaging Zebra fish embryo blood vessels are injected with fluorescence active quantum dots Head: 350 µm thick and 71 images, each of 5 µm apart trunk: 160 µm thick and 80 images, each of 2 µm apart 3D animation of zebra fish head and trunk Source: www.helmholtz-muenchen.de Page 11

Stimulated emission depletion (STED) vibrational relaxation B 3 B 0 Excitation Spontaneous emission (λ EXC ) (λ EM ) Stimulated emission (λ STED ) A 3 vibrational relaxation Laser beam (λ EXC ) excites a molecule to the upper electronic state Another laser beam, called STED beam, at (λ STED ) shines on the excited molecule Stimulates it to undergo emission at (λ STED ) No emission at (λ EM ) i.e. No fluorescence from the excited molecule A 0 Page 12

STED in a confocal fluorescence microscope detector STED beam λ STED Excitation beam λ EXC DBS2 DBS1 λ EM :mean emission wavelength DBS1 : reflects λ EXC and transmits wavelengths >λ EXC DBS2 : reflects λ STED and transmits wavelengths <λ STED Objective lens sample Both excitation and STED beams are pulses following one another, usually derived from the same femto second laser Image is formed by scanning the stage or by scanning the beams Page 13

Applications of STED microscopy Nanoscale imaging of fluorescent beads Confocal image STED image XY plane images of 200 nm fluorescent beads (source: PhD thesis, B R Boruah, Imperial College London) Page 14

Applications of STED microscopy In biological science Confocal image STED image Reveals nanopattern in the in SNAP-25 protein found in the plasma membrane of mamalian cells (source: Briefings in functional genomics and proteomics, Vol 5, No 4, 289-301) Page 15

Applications of STED microscopy Nanoscale imaging of live cells Confocal image STED image Live yeast cells Z X Live E-coli bacteria (source: PNAS, 97, 15, 2000, 8206-8210) Page 16

Fluorescence resonance energy transfer excitation excitation D A D Folded protein A Unfolded protein D : donor fluorescent molecule A : acceptor fluorescent molecule : fluorescence resonance energy transfer (FRET) Energy transfer from D to A when they are close by Fluorescence from A No energy transfer from D to A when they are far apart No fluorescence from A Page 17

Cell protein localizations with confocal FRET Integrins induce local Rac effector coupling. Donor (A), uncorrected FRET (B), and corrected FRET (C) Sekar, Periasamy J. Cell Biol. 2008:160:629-633 Page 18

Fluorescence lifetime imaging intensity intensity intensity τ A τ B excitation excitation time Fluorescence (molecule A) time Fluorescence (molecule B) time A B Time correlated fluorescence collection A Sample plane is excited with short laser pulse (200 ps) Life time (τ) : duration over which the fluorescence decays to 1/e the maximum Lifetime is sensitive to local environment: ph, density of oxygen, Ca ion, proximity to other molecules FLIM Better contrast than intensity imaging Not effected by scattering B Fluorescence lifetime image (FLIM) Page 19

Confocal microscopy with lifetime imaging Source: Photonics group, Imperial College London Images of rat s ear showing two veins, an artery,and an elastic cartilage. (a) Microscopic image, (b) fluorescence image (c) fast FLIM image, (d) slow FLIM image Page 20

Optical trapping medium Laser beam Lens Pico newton level force Particles in a medium (say liquid) Manipulation of trapped micro-beads A. Jesacher, et al., Optics Express, 2006 Laser beam ( 100mW) is focused tightly by a lens into a medium Particle in the medium having contrast in the refractive index will experience pico newton magnitude force towards the focus point changing the direction of the laser beam will change in shift in focal spot along with the trapped particle Page 21

Confocal fluorescence microscopy with optical trapping (a) (b) RBC cell in (a) isotoinic buffer (b) hypertonic buffer Cells with arrow mark are trapped Confocal images from various view angles No change in shape of the trapped cell K Mohanty, et al., JBO, 2007 Page 22

Two Photon excitation (TPE) E2 SPE TPE E1 ν ν fluorescence Z Two photon excitation : E2-E1=2hν X Excited molecules in the sample the time interval between arrivals of the two photons of frequency ν at the site of the molecule <10-16 sec the molecules sees as if there is a single photon of frequency 2ν Excitation probability is proportional to (intensity) 2 Fluorescence emission is only from a small region near the focus unlike in single photon excitation Page 23

Deep tissue imaging using two photon excitation microscopy In vivo imaging of brain tissue of an anesthetized rat (up to a depth of 600 µm) M. Oheim et al, Journal of Neuroscience Methods 111 (2001) Excitation wavelength is twice that of single photon excitation Less scattering (larger the wavelength smaller is the scattering) Excitation beam enters deep into the sample (upto 1 mm) Less amount of photo damage In vivo imaging of live tissues Page 24

Deep tissue imaging using two photon excitation microscopy D Kobat, et al., Optics Express, August 2009 TPE image of mouse brain shows high contrast blood vessels Upto a depth of 500 µm when excited with 775 nm Upto a depth of 1 mm when excited with 1280 nm Page 25

Conclusion confocal fluorescence microscopy is a powerful tool to get a high contrast image of a thin slice of the sample in a noninvasive way Has number of application in biology (and the number is growing every day) Confocal fluorescence microscopy using stimulated emission depletion provides nanoscale imaging Confocal fluorescence microscopy can be combined with other techniques such as FRET, FLIM, optical trapping etc. to reveal further information from the sample Two photon excitation instead of single photon excitation provides high contrast image upto a depth of 1 mm Useful for imaging in cellular environment Page 26

Thank You Page 27