05 Heat Transfer & its Applications



Similar documents
Boiler Preparation, Start-Up and Shutdown

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

Convection, Conduction & Radiation

5.2. Vaporizers - Types and Usage

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Specific Volume of Liquid (Column 7). The volume per unit of mass in cubic feet per pound.

FLASH TANK ECONOMIZER PRODUCT GUIDE

Mechanical Seal Piping Plans

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Name: Class: Date: 10. Some substances, when exposed to visible light, absorb more energy as heat than other substances absorb.

Steam System Best Practices Condensate System Piping

Oil and Coolant Circulating Heating System. Model - OCSM

Energy and Energy Transformations Test Review

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Selecting TEMA Type Heat Exchangers

Every mathematician knows it is impossible to understand an elementary course in thermodynamics. ~V.I. Arnold

Routine and Emergency Boiler Operation

Factory owners must ensure the boiler is:

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

Overview. Introduction Cooling Tower Basics Principles of Operation Types of Cooling Towers Common Applications Design Considerations

Topic Page Contents Page

C. starting positive displacement pumps with the discharge valve closed.

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Glossary of Heating, Ventilation and Air Conditioning Terms

ENGINE COOLING SYSTEM

NFPA31FuelOilPiping 1 Revised

Desuperheater Online Program Sizing Guidance

Refrigeration Basics 101. By: Eric Nelson

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Boiler & Pressure Vessel Inspection discrepancies and failures

Efficiency on a large scale CFB Steam Boilers

(Walter Glogowski, Chaz Shapiro & Reid Sherman) INTRODUCTION

Chapter 4: Transfer of Thermal Energy

How To Clean Water From An Ammonia Refrigeration System

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

Rusty Walker, Corporate Trainer Hill PHOENIX

How does solar air conditioning work?

Cooling system components, removing and installing

COMMISSIONING OF HVAC SYSTEMS

Cooling system components, removing and installing

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

UNIT 1 GCSE PHYSICS Infrared Radiation 2011 FXA

Chapter 18 Temperature, Heat, and the First Law of Thermodynamics. Problems: 8, 11, 13, 17, 21, 27, 29, 37, 39, 41, 47, 51, 57

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

The Three Heat Transfer Modes in Reflow Soldering

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

I. STEAM GENERATION, BOILER TYPES

Heating Water by Direct Steam Injection

A Guide to Trouble-Free Cooling Towers

The soot and scale problems

BOWIE PUMPS OPERATION - MAINTENANCE

A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Evaluate, Clean, and Tune Guidance

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Steam Jet Vacuum Pumps

Why use Tigerloop in fuel heating systems?

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Mechanical Seal Piping Plans

IGEMA BOILER LEVEL & TDS CONTROLS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Installer s Guide 18-AH39D1-13

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

Why and How we Use Capacity Control

OTF Oil Fired Pool Heater

Chapter 2: Forms of Energy

Air Eliminators and Combination Air Eliminators Strainers

How To Understand Evaporator

REGULATORS 175/153 Series

How Ground/Water Source Heat Pumps Work

VAD. Variable Area Desuperheaters

How To Clean Up A Reactor Water Cleanup

Basics of Steam Generation

Steam System Efficiency. Bill Lumsden Leidos Engineering

Boiling Water Reactor Systems

Originators of the Flexible Water Tube design

TEACHER BACKGROUND INFORMATION THERMAL ENERGY

OBSERVING BOILER SAFETY RULES

Module 2.2. Heat transfer mechanisms

Description of Thermal Oxidizers

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Energy Efficient Operations and Maintenance Strategies for Boilers

Gas-Fired, Residential Storage Type Water Heaters

Chilled Water HVAC Systems

Boiler and Burner Cleaning and Servicing Specifications

Hot water supply, distribution and use

A/C refrigerant system, overview

Steam Generation Efficiency Module Blowdown Losses Section

Fuel Treatment and Conditioning Systems

Draining and filling cooling system

Alfa Laval in brief Alfa Laval is a leading global provider of specialized products and engineering solutions.

Preventing Overheated Boiler Incidents

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

Some Criteria for Choosing a Steam Boiler for a Microbrewery

This will also provide you with the knowledge to insure long life for your Investment

Float and Thermostatic Traps Series H, C and X

AIR CONDITIONING TECHNOLOGY

AZ State Standards. Concept 3: Conservation of Energy and Increase in Disorder Understand ways that energy is conserved, stored, and transferred.

Practice Test. 4) The planet Earth loses heat mainly by A) conduction. B) convection. C) radiation. D) all of these Answer: C

Transcription:

05 Heat Transfer & its Applications

Heat Transfer & its Applications Objectives When you have completed study of this chapter you should be able to: Get familiar with the various types of heat transfer methods; Be familiar with the classification of heat transfer equipments; Know the routine checks to be carried in a operating process plant; 5.1 Heat Transfer Principles There are three fundamentals modes in which heat is transferred. In fluids, heat is often transferred by convection, in which the motion of the fluid itself carries heat from one place to another. Another way to transfer heat is by conduction, which does not involve any motion of a substance, but rather is a transfer of energy within a substance (or between substances in contact). The third way to transfer energy is by radiation, which involves absorbing or giving off electromagnetic waves. 5.2 Modes of Heat Transfer When two substances at different temperatures are brought into thermal contact, there is heat flow from the body at higher temperature to the one at lower temperature. The net flow always occurs in the direction of the temperature decrease. Heat may flow by one or more of three basic mechanisms: conduction, convection and radiation. 5.2.1 Conduction When heat is transferred through conduction, the substance itself does not flow; rather, heat is transferred internally, by vibrations of atoms and molecules. Electrons are also carry heat, which is the reason metals are generally very good conductors of heat. Metals have many free electrons, which move around randomly; these can transfer heat from one part of the metal to another. The equation governing heat conduction along something of length (or thickness) L and cross-sectional area A, in a time t is: k is the thermal conductivity, a constant depending only on the material, and having units of J / (s m C). Copper, a good thermal conductor, which is why some pots and pans have copper bases, has a thermal conductivity of 390 J / (s m C). Styrofoam, on the other hand, a good insulator, has a thermal conductivity of 0.01 J / (s m C). 5.2.2 Convection Heat transfer in fluids normally proceeds via convection. Convection currents are set up in the fluid because the hotter part of the fluid is not as dense as the cooler part, so there is an upward buoyant force on the hotter fluid, making it rise while the cooler, denser, fluid sinks. Birds and gliders make use of upward IDC Technologies Ver 1.02 UK English 102

Practical Fundamentals of Chemical Engineering convection currents to rise, and we also rely on convection to remove groundlevel pollution. Forced convection where the fluid does not flow of its own accord but is pushed, is often used for heating (e.g., forced-air furnaces) or cooling (e.g., fans, automobile cooling systems). Natural convection The motion of the fluid is totally the result of differences in density due to temperature changes, eg the flow of air across a heated radiator. The two forces may be active simultaneously in the same fluid, resulting in natural and forced convections. 5.2.3 Radiation The third way to transfer heat, in addition to convection and conduction, is by radiation, in which energy is transferred in the form of electromagnetic waves. An electromagnetic wave is basically an oscillating electric and magnetic field traveling through space at the speed of light. The only difference between the different kinds is the frequency and wavelength of the wave. The radiation comes in the form of very high energy electromagnetic waves, as well as nuclear particles. The radiation associated with heat transfer is entirely electromagnetic waves, with a relatively low (and therefore relatively safe) energy. It is apparent that a majority of our activities takes in energy from radiation and gives it off in the form of radiation. When the associated system is at the same temperature, the amount of energy received is equal to the amount given off. Because there is no net change in energy, no temperature changes occur. When things are at different temperatures, however, the hotter objects give off more energy in the form of radiation than they take in; the reverse is true for the colder objects. The amount of energy an object radiates depends strongly on temperature. For an object with a temperature T (in Kelvin) and a surface area A, the energy radiated in a time t is given by the Stefan-Boltzmann law of radiation: The constant e is known as the emissivity and it's a measure of the fraction of incident radiation energy is absorbed and radiated by the object. This depends to a large extent on how shiny it is. If an object reflects a lot of energy, it will absorb (and radiate) very little; if it reflects very little energy, it will absorb and radiate quite efficiently. Black objects, for example, generally absorb radiation very well, and would have emissivities close to 1. This is the largest possible value for the emissivity, and an object with e = 1 is called a perfect blackbody. IDC Technologies Ver 1.02 UK English 103

Heat Transfer & its Applications The emissivity of an object depends on the wavelength of radiation. A shiny object may reflect a great deal of visible light, but it may be a good absorber(and therefore emitter) of radiation of a different wavelength, such as ultraviolet or infrared light. Also, the emissivity of an object is a measure of not just how well it absorbs radiation, but also of how well it radiates the energy. This means a black object that absorbs most of the radiation it is exposed to will also radiate energy away at a higher rate than a shiny object with a low emissivity. The Stefan-Boltzmann law defines how much energy is radiated from an object at temperature T. It can also be used to calculate how much energy is absorbed by an object in an environment where everything around it is at a particular temperature : The net energy change is simply the difference between the radiated energy and the absorbed energy. This can be expressed as a power by dividing the energy by the time. 5.3 Industrial Applications Heat transfer methods finds a variety of applications in the chemical process industries. Heating and Cooling of Batch Tanks This application will allow the user to calculate the time it takes to heat up and then cool a batch vessel or tank. The heating methods supported are: Steam Jacketing or Coil Tempered Water Jacket or Coil Direct Steam Injection Electrical Heating Jacket The cooling methods supported are: Water Jacketing or Coil External Cooler (Heat Exchanger) Direct Water Mixing IDC Technologies Ver 1.02 UK English 104

Practical Fundamentals of Chemical Engineering 5.4 Heat Exchangers Heat exchangers play an important role in process industries. A heat exchanger is a device which is used for transferring heat from one fluid to another through a separating wall. This can be classified according to the process of heat transfer, mechanical design and principal material of construction. 5.4.1 Classification of Heat Exchangers The following types of heat exchangers are presently used in process industries. Double pipe heat exchangers (Figure 5.1) Shell and tube heat exchangers - Fixed tube sheet - Outside packed floating head - Internal floating head - U-Tube type - Reboilers B D E A C (A) outer pipe (B) inner pipe (C) return bend (D) gland width packing (E) support bracket Figure 5.1 Double Pipe Heat Exchanger IDC Technologies Ver 1.02 UK English 105

Heat Transfer & its Applications Special types of exchangers - Pipe coils - Spiral heat exchanger - Plate type exchanger - Finned tube exchanger - Graphite heat exchanger - Air-cooled exchanger - Falling-film exchanger 5.4.2 Standard Operating Procedure Equipment handing over to maintenance Equipment is required to be handed over during shutdown/normal operations for maintenance purposes. Procedures given below should be followed to ensure their safe release and safe maintenance work. Isolate and decommission the exchanger as per the procedure Open the vent valves to ensure complete draining Provide blinds for the exchanger on both sides Attach steam connection to top nozzle. Steam for 4 hours Release the equipment for maintenance jobs Equipment taking over from maintenance If equipment is not properly checked when taking over from maintenance, it may result in accidents or give trouble during start-ups. Check the following items while taking over from maintenance. Tube and shell properly cleaned Leaky tubes are plugged/replaced Shell is painted as per inspection Exchanger is properly boxed up with gaskets Check for short bolting Insulation is complete Set is deblinded Electrical/earthing connections are complete 5.4.3 Commissioning Procedure The heat exchanger must be deblinded Keep the vent valves of both shell and tube side open Remove air by steaming or filling with flushing oil In case of flushing oil fitting, provide an extension hose on vent line for safe disposal of oil Close the vent valves and provide caps Pressure test with steam for any leaks IDC Technologies Ver 1.02 UK English 106

Practical Fundamentals of Chemical Engineering Commission cold side gradually Open outlet valve of heating medium gradually Open inlet valve of heating medium gradually Close bypass valve of cold side Close bypass valve of hot side Check for any leaks Carry out hot bolting 5.4.4 Decommissioning Procedure Gradually open bypass valve on heating medium side Close the inlet valve on heating medium Close outlet valve on heating medium Leave outlet valve open if exchanger is not to be drained / depressurized Open bypass valve of cold medium of exchangers Close inlet and outlet valves of cold medium side Flush the shell/tube side of the sets which must handle high pour-point hydrocarbon If the system pressure is low, open the outlet valve of the set to displace heavy hydrocarbons into the system itself If the exchanger is not to be handed over to maintenance, it need not be depressurized/drained 5.4.5 Routine Checks The following checks should be carried out regularly. Inlet/outlet temperatures and pressures on both sides to assess the performance Any leakages 5.5 Condensers Special heat-transfer devices employed to liquefy vapors by removing their latent heat are called condensers. The latent heat is removed by absorbing it in a cooler liquid called the coolant. Since the temperature of the coolant is increased in a condenser, the unit also acts as a heater. 5.5.1 Classification of Condensers Condensers fall into three classes. Shell-and-tube condensers Contact condensers Dehumidifying condensers ( Figure 5.2 ) IDC Technologies Ver 1.02 UK English 107

Heat Transfer & its Applications Vapor inlet Water outlet Water inlet Tapped holes for stud bolts Floating tube sheet skirt Vapor outlet Floating tube sheet Stuffing box Rings of square packing Follower Slip of backing flange Split shear ring Vapor liquid separating cone Condensate outlet Floating head cover Figure 5.2 Dehumidifying Condenser 5.6 Boilers & Calandrias A boiler is a device, consisting of a pressure vessel and heating surfaces, for transforming water to steam. It includes a furnace, as well as auxiliary equipment such as burners, feed water pumps, draft fans and controls. In continuous-flow process plants, liquids are boiled in kette-type boilers containing a pool of boiling liquid or in vertical-tube calandrias through which the liquid and vapor flows upward through the tubes. 5.6.1 Types of Boilers Stationary field-extracted boilers Operating pressures range from a minimum of 600 psi to 5,000 psi. Stationary packaged boilers - Operating pressures range from a minimum of 250 psi to 900 psi. Supercritical boilers - Operating pressures range from a minimum of 3,500 psi to 5,000 psi. IDC Technologies Ver 1.02 UK English 108

Practical Fundamentals of Chemical Engineering Marine boilers - Operating pressures range from a minimum of 900 psi to 1,200 psi. Waste heat boilers - Operating pressure to a maximum limit of 800 psi. Kettle-type boilers(figure 5.3) Where psi is Pounds per square inch Shell Vapor outlet Auxiliary nozzle Steam inlet Condensate outlet Liquid feed Tube supports Tubes Hot liquid outlet Figure 5.3 Kettle-type boilers 5.6.2 Calandrias Vertical shell-and-tube units, known as calandrias, natural-circulation or thermosiphon reboilers, are generally the most economical vaporizers for distillation and evaporation operations. 5.6.3 Preparation for Start up Check whether all the manholes are closed and keep all the controls on manual. Keep starting vent, drum vent and superheater header outlet drain open and close all other valves. Check the deaerator level and start feed water pump. Increase the level in the steam drum to the required level Keep the flue gas exit damper and all air doors in burners open. Check whether LPG cylinder is connected for LPG header (also ensure sufficient stock). Check the condition of the ignitors. IDC Technologies Ver 1.02 UK English 109

Heat Transfer & its Applications 5.6.4 Routine Check-up During Normal Run Check the drum level once in two hours and ensure whether both the level transmitter readings match with direct level gauge glass. Check whether the air doors of all burners in service are fully opened Check the flame condition of burners regularly. Ensure that the Fuel oil (FO) isolation valves of all burners not in service are closed Check all the oil drains for closed condition. Check the oil heater trap outlet for any leak. Check the pressure drop across suction and discharge oil filters. Check the FO tank temperature. Check the bearing temperature and lube oil level of FO pump, Boiler Feed Water (BFW) pump and Forced Draft (FD) fan. Check the lube oil level, Rpm, regulating oil pressure and lube oil pressure of BFW, FD and FO turbines. Check the shaft movement in BFW pumps and pressure drop across suction strainer. Check the Deaerator level and check whether it matches direct level indicator. Check for any flue gas leak through Boiler ducts. Check for any leaks through pressure parts. 5.6.5 Shut Down After getting clearance from process plants to cut out steam supply, trip the Boiler from the control panel. Close the main stop valve, Continuous Blow Down (CBD), auxiliary steam valve, sampling root valve and dosing valves. Increase the drum level to required value and stop the feed pump. Stop Heavy Fuel Oil (HFO) pump and dosing pumps. If a long shut-down is planned, ensure there is no fuel oil in the tank. Stop FD fan after 10 minutes and allow natural cooling of the Boiler Close all individual FO isolation valves and atomizing steam isolation valves. Remove all the guns for cleaning. Open all the trap bypasses. When the drum pressure reaches the required value, start vent. If a long shut-down is planned, ensure there is no fuel oil in the tank. IDC Technologies Ver 1.02 UK English 110

Practical Fundamentals of Chemical Engineering 5.7 Evaporators The objective of evaporations is to concentrate a solution consisting of a nonvolatile solute and a volatile solvent. 5.7.1 Types of Evaporators The types of evaporators in use today are Long-tube vertical evaporators ( Figure 5.4 ) - Upward flow (climbing-film) - Downward flow (falling-film) - Forced circulation Agitated-film evaporators Standard vertical short tube Evaporators (Calendria Type) Basket Evaporator External Calendria vertical tube Evaporators Horizontal tube Evaporators Forced circulation Evaporators Multiple effect Evaporator (Figure 5.5) Upward flow (climbing-film) evaporator The essential parts are A tubular exchanger with steam in the shell and liquid to be concentrated in the tubes A separator or vapor space for removing entrained liquid from the vapour When operated as a circulation unit, a return leg for the liquid from the separator to the bottom of the exchanger. Inlets are provided for vapour,thick liquor,steam condensate and noncondensate gases from the steam. Long tube vertical evaporators are especially effective in concentrating liquids that tend to foam. This foam is ultimately broken when the high-velocity mixture of liquid and vapour impinges against the vapour-head baffle. IDC Technologies Ver 1.02 UK English 111

Heat Transfer & its Applications Figure 5.4 Long-tube vertical evaporators IDC Technologies Ver 1.02 UK English 112

Practical Fundamentals of Chemical Engineering Multiple effect Evaporator A number of evaporators are used in series in order to economize the use of steam. In order to utilize the vapours from each stage as stream in a subsequent stage, it is necessary to use lesser steam pressures in each stage. This involves passing the vapours to a surface condenser or a barometric condenser, where the vapours are finally condensed and produce the necessary vacuum. In addition a suitable pump is provided to remove air and non-condensables entrained by the liquor or entering through leakage. C A B Multiple effect evaporator. (A) evaporator (B) separator ( C) barometric condenser Figure 5.5 Multiple Effect Evaporator IDC Technologies Ver 1.02 UK English 113