DKG 972 Gas Burner Safety Control



Similar documents
DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

DVI 980/982 (Honeywell Nr. S4865) Gas Burner Safety Control

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table


MOUNTING AND OPERATING INSTRUCTIONS


ONE STAGE GAS BURNERS RIELLO 40 FS SERIES FS kw FS kw FS kw FS kw FS kw

HERZ-Thermal Actuators

TWO STAGE GAS BURNERS RIELLO 40 GSD SERIES GS10D 29/ kw GS20D 58/ kw

PUSH BUTTON START INSTALLATION MANUAL

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Drayton Digistat +2RF/+3RF

Digital input modules

Voltage Regulator SPAU 341 C. Product Guide

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

AUTODIALLER / QUICKDIALLER - SA132

Technical Data. Dimensions

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

I D F GB E NL GS3 551T GS3 551T1

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

7800 SERIES RM7838B,C Relay Module

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

7800 SERIES EC7895A,C; RM7895A,B,C,D and RM7896A,B,C,D Relay Modules

Thermo Top - Troubleshooting Tree

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

NC-12 Modbus Application

OPL BASIC. Dosing System for Professional Laundry machines. Contents

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Data Sheet. Electro-mechanical counters Hengstler 800 series

Mobile Data Power Model: MDP-25

Manual for Fire Suppression & Methane Detection System

Öl-Gebläsebrenner Brûleur fioul Oil burner Stookoliebrander

Duct Humidity Transmitter

Quick Connect. quick - simple - efficient.

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

OZW30. Central Unit SYNERGYR

B/S/H/ Error codes and service programmes PH

Model Description / Applications. Intermittent Pilot Gas Ignition Control

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

User s Manual Before using the inverter, you need to read and save the safety instructions.

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

SELECTION, APPLICATION AND MAINTENANCE

MasterINTERFACE 39 Series - Relay interface modules

SX460. Generator Automatic Voltage Regulator Operation Manual

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

TMS TANK MANAGEMENT SYSTEM

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

14. Troubleshooting Guide

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

Single Channel Loop Detector

1 QPro HelpFile 01.EN COPYRIGHT CONTRIVE

Power Socket (2 Gang)

Inwall 4 Input / 4 Output Module

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

GREISINGER electronic GmbH

Oil Burner Controls LMO24... LMO44...

Installation Guide. DEVIreg 530. Electronic Thermostat.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Technical Information

Servicing manual. Gas wall hung boiler condensing 600 Series - 11S / 19S / 24S / 24C /2006 GB(EN) For trade use

Technical Information

13 SERIES. Electronic step relays A

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

Operating instructions IV / 2007

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Oil - kerosene burners

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

For installation guide see reverse of book

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

i ChatterBox! Motorcycle Security

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

3/2-way Solenoid Valve, direct-acting, NC or NO

WE-350 Series ¼ Turn Electric Actuator

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

*.ppt 11/2/ :48 PM 1

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

Rousseau 10. User Guide

TT 49 MICROPROCESSOR-BASED DIGITAL ELECTRONIC TIMER. OPERATING INSTRUCTIONS Vr. 01 (ENG) - cod.: ISTR TECNOLOGIC S.p.A.

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

Burner controls. Building Technologies Division Infrastructure & Cities Sector

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Transcription:

A Honeywell Company Gas Burner Safety Control For 2-stage atmospheric gas burners Flame detection: - Ionisation probe - Infrared-flicker detector IRD 1020.1 - UV flame sensor UVD 971 EN1C-0127SZ20 R0305 INTRODUCTION The burner control box controls and supervises atmospheric burners for gas. They are approved and certified according to the applicable European standards and regulations. The microprocessor-based programming sequence ensures extremely stable timings independent of voltage variations, ambient temperature and/or switch-on cycles. The built-in information system not only provides a continuous monitoring of the actual state of the box (very helpful especially for monitoring the start-up phase) but also informs about the cause of a possible. The cause is stored in such a way that it can be retrieved even after a power failure. The control box is designed for maximum safety in case of fluctuations in the voltage supply. If the mains voltage drops below the permitted level, operation is interrupted and the control box automatically prevents the start sequence from being repeated. In this way, the safety of the system is not put at risk by a drop in the mains voltage. This low-voltage protection works not only during start-up but also permanently during operation. CONSTRUCTIONAL FEATURES The control box circuitry is protected by a flame resistant, transparent plug-in type plastic housing. A central fixing screw locks the control box to the wiring base. The plug-in control box incorporates the microprocessor based timer, flame check and reset circuits. Manual reset from and set to is provided by a push button with an integrated LED information system. A variety of cable entry points provides complete flexibility for electrical wiring. The wiring base S98 is equipped with spare- and extraterminals and allows together with a variety of cable entry points utmost flexibility of electrical wiring. The are compatible with the TFI 812. Different are only the pre- and post-ignition times. Max. heating power according the limits in the Gas Appliance Directive. 1 TECHNICAL DATA Operating voltage 220 / 240 V (-15... +10%) 50 Hz (±5%) or 110 / 120 V (-15... +10%) 60 Hz (±5%) Fuse rating 10 A fast, 6 A slow Power consumption ca. 12 VA Max. load per output - term. 3 ignition trafo 1.0 A, cos ϕ 0.2 - term. 5 + 6 solenoid valves 0.5 A, cos ϕ 0.4 - term. 7 alarm indicator 0.5 A, cos ϕ 0.4 - term. 4 auxiliary blower 2.0 A, cos ϕ 0.4 total load 4.0 A, cos ϕ 0.4 max. 16 A during 0,5 sec Reset time from none Re-cycling / repetition (max. 4x) after a loss-of-flame during operation Sensitivity 1 µa min. ionisation current required 1.5 µa Sensitivity for stray light 0.4 µa Ionisation probe insulation probe - earth greater than 50 MΩ Stray capacitance probe- earth less then 1000 pf max. cable length < 3 m Flame detectors IRD 1020.1 side-on or end-on viewing UVD 971 end-on viewing Weight incl. Wiring base 190 g Mounting position any Protection class IP 40 Approved ambient parameter for control and flame detector max. 95% at 30 C - for operation -20 C... +60 C - for storage -20 C... +80 C Build-up of ice, penetration of water and condensing water are Approvals according to European standards Classified acc. to EN 298 inadmissible EN 298 and EN 230, as well as all other relevant Directives and standards ATLLXN Table of timings (sec.) Model waiting time start pre-ignition time Stray light monitoring safety time post-ignition time delay 2nd-stage tw tvz tf ts tn tv2 05 12 3 5 5 4 25 10 12 3 5 10 9 25

APPLICATION FEATURES 1. Information system The information system is microprocessor based and reports on all aspects of burner control box operation and flame supervision. It informs continuously about the actual programming sequence the unit is just performing. Besides monitoring of the programming sequence it also allows to identify errors during start-up of operation without any additional testing devices. The automatically performed diagnosis is a valuable tool which facilitates service/ maintenance work and therefore saves costs. The analyses of the error cause can be done directly on stage or if not possible afterwards as the reason is stored in a nonvolatile mode memory. The information system communicates with the outside world using a LED (the used Flash-Code is similar to the Morse-Code). The messages are optically transmitted by a appropriately flashing LED. Using an additional terminal (optional), the messages can be recorded and displayed in easy readable form. 1.1 Programming sequence display The built-in microprocessor controls not only the programming sequence but the information system too. The individual phases of the programming sequence are displayed as Flash-Code. The following messages can be distinguished: Message Flash-Code waiting time. tw pre-ignition. tvz safety time ts. post ignition tn delay time to valve V2. tv2 running _ low mains voltage Internal fuse defect > control box defect Description = short pulse = long pulse. = short pause _ = long pause _ _ 1.2 Lock-out diagnoses In case of a failure the LED is permanently illuminated. Every 10 seconds the illumination is interrupted by a flash code, which indicates the cause of the error. Therefore the following sequence is performed which is repeated as long as the unit is not reset. Sequence: illuminated phase dark phase Flash-Code dark phase for 10 sec for 0.6 sec for 1.2 sec Error diagnosis Error message Flash-Code Possible fault lockout within safety time no flame establishment stray light stray light during monitored phase, detector may be faulty Flash-Code for manual manual/external (see also 3. and reset) 2. Flame detection The following types of flame detectors are suitable: Ionisation probe, temperature resistant material, well insulated (material and insulation same as for ignition electrode). Infrared-flicker detector type IRD 1020.1 with mounting flange M 93 or the UV solid state flame sensor UVD 971. Flame detection using an ionisation probe is only possible in conjunction with mains supplies which provides a neutral earth connection. Connecting the IRD 1020.1 or UVD 971 the correct wiring has to be observed. 2.1 Stray light monitoring The stray light check is performed at the end of the prepurge time for thr duration as mentioned in the table of timings. 2

3. Lock out and reset The unit can be reset or brought into mode in two different ways: Internal In the case the unit can be reset by pushing the builtin button meaning a new start-up cycle is performed. External Instead of using the built-in button the same function can be achieved by using an external button which connects terminal 9 with A (see also circuit and block diagram). If the pushputton (internal or external) is pressed during normal operation or during the start sequence for more then 3 sec. and afterwards released, the control box will perform a shutdown. Please note The unit can only be brought to lockout mode or be reseted if power is applied to the unit. 6. Mounting and electrical wiring Wiring base: 3 earth terminals with additional terminal for burner earthing 3 neutral terminals with internal permanent connection to neutral terminal 8 2 independant spare terminals (S1 and S2) extra terminals A, B and C are standard (wiring base S98 12-pin) 2 slide-in plates and 2 easy knock out holes plus 2 knock out holes in the base bottom faciliate the base wiring Please note To assist trouble-free operation the main neutral connection terminal 8 in the wiring base must be fully tightened. The terminal screws are already in the undone position. To connect a wire to the terminal, the screw only needs to be fastened. General: The control box and detector probes should not be subjected to excessive vibration. 4. Low-voltage protection at 220 / 240V (110 / 120V) nominal voltage The mains voltage has to be more than 187 V eff (94 V eff ) in order to allow the unit to perform a start-up. The mains voltage is not only monitored in the start-up phase but also permanently during operation. If the voltage drops below < 160 V eff (80 V eff ) during start-up or run time the control box proceed to safety shut-down and goes into a waiting status. If the voltage rises again, the control box performs automatically a start-up as soon as the mains voltage is > 187 V eff (94 V eff ). 5. Safety The design and control sequence of the controls will comply with the currently applicable standards and regulations (see also TECHNICAL DATA). 3

INSTALLATION INSTRUCTIONS AND MAINTENANCE 1. Important notes The controls must be installed by qualified personnel only. The relevant national regulations have to be observed. On commissioning the wiring has to be carefully checked according the appropriate diagram, Incorrect wiring can damage the unit and endanger the installation. The fuse rating has to ensure that the limits specified in TECHNICAL DATA will not be exceeded. If these precautions are not observed, the effect of a short circuit can cause severe damage to the control and installation. For safety reasons a minimum of one control shutdown every 24 hours has to be observed. Disconnect the mains before the control box is plugged in or out. The control box is a safety device and must not be opened! 2. Function control For safety reasons the flame detection system should be tested on commissioning the installation as well as after a service or longer shut-down. a) Attempt to start with gas valve closed: At the end of the safety interval -> Lockout b) After a normal start, with the burner in operation, close the gas valve: After restart at the end of the safety interval -> Lockout 3. Fault finding The built-in information system facilitate the trouble shooting in the case of problems occurring during start-up or during operation. A list of possible messages can be found in APPLICATION FEATURES chapter 1.2. Please note: The control box is locked in mode and the reasen for the is displayed until the control box is reset, either by an internal or external reset (see also subject 3. Lock out and reset"). Removing the control box from its wiring base or by interrupting the supply line may not reset a. Therefore, by applying power, it needs 2-3 secs. before the control box goes to again and the cause of the last. Error Possible fault Burner not working - Thermostat circuit open - Faulty electrical wiring - Mains voltage < 187 V (< 80 V) - Terminal A continuously on power (e.g. terminal A is used as a support terminal) After 2-3 secs. after applying - Control box has not been reseted power. the unit goes to Burner starts, - stray light signal during waiting flame not established, time - no ignition or no fuel Burner starts, - no or too low flame signal (min. flame established, valves see TECHNICAL DATA) after safety time, - wrongly wired, phase and neutral reversed - Ionisation probe dirty, broken or has contact to frame ground - too little light on flame sensior (IRD) 4

CIRCUIT AND TIMING DIAGRAM Ph max. 10 A fast 6 A slow HS ST GW RT EV N 1 2 3 4 5 6 7 8 9 A V1 IS M Z V2 SA HS GW ST RT EV IS Z V1 V2 SA M Mains switch Gas proving switch Limit thermostat Control thermostat External reset and button Ionisation probe (IRD 1020.1, UVD 971see separate diagram) Ignition Solenoid valve, 1st-stage Solenoid valve, 2nd-stage External signal Auxiliary blower tw tf tvz tn ts tv2 tw tf tvz tn ts tv2 Waiting time Stray light monitoring Pre-ignition time Post-ignition Safety time 2nd-stage delay IRD- OR UVD CONNECTION IRD 1020.1 UVD 971 blue black brown term. 8 term. 1 term. 9 BLOCK DIAGRAM Oscillator EEPROM Fault display Information system µc Watchdog Reset and Reset µc Mains monitoring Flame amplifier Power supply monitoring RZ RV1 RV2 RS Power supply rz rv1 rv2 rs 1 3 4 5 6 7 8 9 A 5

AND SOCKET 4,5 HOLDER M 93 FOR IRD 35 3 62,5 38,5 14 4.5 26 24 15.1 86 60 48 4 Reset button 24 Slide-in plate 17 ø20.5 30 30 16 44 M4 Earth 25 35 HOLDER M 74 FOR UVD 35 3 ø 14 4,5 26 30 57-60 Underside cable entry ø16 mm ø20 4 48 7 UVD 971 IRD 1020.1 29 29 50 UVD = 29 IRD = 44 21,8 21,8 ø13,5 VARIATION IRD right UVD = 89 IRD = 104 axial left ORDERING INFORMATION ITEM DESIGNATION ITEM NO. Control box Mod. 5 0332005 Control box Mod. 10 0332010 Control box Mod. 10 110 / 120V 50Hz 0332310 Control box Mod. 10 110 / 120V 60Hz 0332410 Socket Wiring base S98 12-pin 75310 Insert plate PG-Plate 70502 optional Cable entry plate 70503 Flame detector IRD 1020.1 end-on 16532 Flame detector IRD 1020.1 left 16533 Flame detector IRD 1020.1 right 16531 optional UVD 971 16722 Support for IRD Holder M93 for IRD 1020 59093 Support for UVD Holder M74 for UVD 59074 Connection cable Plug type, 3 core cable, 0.6 m with tag wire ends 7236001 The above ordering information refers to the standard version. Special versions are also included in our product range. Specifications subject to change without notice 6 A Honeywell Company Satronic AG Honeywell-Platz 1 Postfach 324 CH-8157 Dielsdorf