Carbon Monoxide (CO) Gas Detection and Control System



Similar documents
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Electronic Control Devices The European Product Catalogue 2007

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Duct Humidity Transmitter

Electronic Control Devices The European Product Catalogue 2007

FX07 Field Controller

T7560A,B,C Digital Wall Module

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

FIREDEX Conventional Fire Panels

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TC-9102 Series Surface Mount Temperature Controllers

Series B14 Monitor System

FX07 Field Controller

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Model: DC-A2IO Advanced HVAC Controller

WD-AMX Water Detection Controllers

TrueAlarm Fire Alarm Systems

SECTION NOx, CO AND NATURAL GAS DETECTION, MONITORING AND ALARM CONTROL SYSTEMS

PIEZOMETER AIRFLOW MEASURING RING

HMI display Installation Guide

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

T0118 T2118 T3118. Instruction Manual

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

System 350 A350E Electronic Cooling Control

Temperature & Humidity SMS Alert Controller

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Lockout Specification BW Clip Maintenance-free single gas detector

UM-X Field display for continous level sensors

Contents. Document information

Centro-Matic Automatic Lubrication Systems System Controls

INSTALLATION INSTRUCTIONS

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Radiant Temperature Sensor TY7321

NC-12 Modbus Application

Preliminary. Dual-line FLOW rate/totalizers. Pr ovu Model PD6200 Analog Input. Pr ovu Model PD6300 Pulse Input. Analog Inputs.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Panel Meters and Controllers Modular Panel Meter Type EDM 35

Short information Parameters are programmed via front-side membrane keypad

AquaTrend Interface. Model AquaTrend Model AquaTrend/SOM Model51400 PortableAquaTrend. Instrument Manual. Catalog Number

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Pump_PT580. Optional. Optional. Modbus. Remote Reset Local Display PLC/DCS PT580-CFG PCM370 DTM96. Buffered Output. Dual Relay Output.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

O C M III. Open Channel Flow Monitor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

is then retained absolutely without interruption.

Y7230A CO 2 Alarm System

Input signal Maximum Range Accuracy. Thermocouple E -50 to 700 C (-58 to 1832 F) ±1 C

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Installation and User Guide

Digital Pressure Measuring Instrument MDR480

Repeaters and Mimics Data Sheet

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Nokeval. User's Manual Models 301 / 302 / 305

T7079A,B Solid State Remote Temperature Controllers

Pressure Switch for gas and air

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Water Leak Detection System

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Fire & Security DETECTORS

AIS750 Series Alarm Annunciator

User Manual. Humidity-Temperature Chart Recorder. Model RH520

PCS0100en Persy Control Services B.V. Netherlands

Preset Counter signo 721

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

T775U Series 2000 Electronic Stand-Alone Controller

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

mecotron Safety relay ESTOP-2 For emergency stop monitoring

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

PD 100A. Printing data system

IO-DIM6 6-Channel, Digital to Analogue Converters

ISOMETER IRDH275. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Vorläufiges Datenblatt

Buckeye Detection Systems Fixed Detection Systems Application Survey

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Problem / Solution. The problem:

Modular I/O System Analog and Digital Interface Modules

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

PRODUCT PROFILE FEATURES

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Class 2 transformer (TBT) Low Tension Conform to EN A LED turns ON when the current exceeds 1 A at the 14V output connector

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

Chapter 9 N.C. C. N.O. Single-Pole Double-Throw

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Actuator for modulating control AME 435

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Transcription:

Carbon Monoxide (CO) Gas Detection and Control System Specifications subject to change without notice. USA 4094 Page of 6 DESCRIPTION Carbon monoxide (CO) detection and control system, wall-mounted, with one, two, three or four remote sensors/transmitters. PolyGard LGC-CO APPLICATION To detect and control levels of carbon monoxide (CO) in a wide variety of commercial and industrial applications such as vehicle exhaust in parking structures, engine repair shops, equipment rooms and ventilation systems, etc. The controller can interface via binary outputs and up to () signals with any compatible electronic analog control, DDC/PLC control or automation system. FEATURES Continuous monitoring CO electrochemical sensor, gas specific Polarity protected Up to (4) sensor inputs Four (4) digital inputs Five (5) relay outputs: - Five-stage control - Fail-safe assignable Two () analog outputs, - Selectable for low, high or averaging Optional BACnet coupler upwards communication to BAS Liquid Crystal Display (LCD) ORDERING INFORMATION LED status indicators Built-in horn Keypad user interface Simple menu-driven programming RFI/EMI protected Modular plug-in technology Overload & short-circuit protected NEMA 4X, transmitter enclosure NEMA 4X, controller enclosure Easy maintenance City of Los Angeles Approved NRTL Performance Tested & Certified Conforms to STD UL 075 / UL 07 Upwards Communication Options BACnet Carbon Monoxide (CO) Detection and Control System Package Controller Sensor(s) / Transmitter(s) Part Numbers Digital programmable menu-driven keypad user interface LCD & LEDs,, NEMA 4X enclosure Inputs: (4) Outputs: (5) Relays, SPDT, 8 A () Built-in () Horn Sensor range: 0-50 ppm CO,, -wire, loop powered, NEMA 4X wall mount enclosure Incl. () CO remote sensor Incl. () CO remote sensors Incl. (3) CO remote sensors Incl. (4) CO remote sensors LGC-CO-0 LGC-CO-0 LGC-CO-03 LGC-CO-04 BACnet upwards communication coupler T5-BAC--A (external) T5-BAC--A Factory configured CO alarm levels/setpoints: Low alarm @ 5 ppm (relay #0) Horn alarm @ 00 ppm (relay #05) High alarm @ 00 ppm (relay #0) Other setpoints/programming are available on special request. All devices are field programmable and adjustable.

Specifications subject to change without notice. USA 4094 Page of 6 SPECIFICATIONS Electric Power supply - controller, -5%/+0%, 50/60 Hz, auto-resettable fuse - sensor(s)/transmitter(s) from controller, loop powered, polarity protected Power consumption 3 VA (0.5 A), w/max sensor connections RF/EMI protected 4.0 W @ 3 ft. ( m) radiated Sensor Performance Gas detected Carbon monoxide (CO) Sensor element Electrochemical, diffusion Range Span field adjustable from 0-00 to 0-300 ppm via calibration, 0-50 ppm factory set Resolution ± 3.0 ppm of reading Repeatability ± 3.0% of reading Long term output drift < 0.4% signal loss/month Response time t90 < 50 sec. Sensor element life expectancy 3-5 years, normal operating environment Sensor coverage 5,000 sq.ft., max. 0,000 sq.ft. (465 m, max. 930 m ), under ideal conditions Installation Location Sensor mounting height 5 to 6 ft. (.5 to.8 m) above floor Type of Control General Analog inputs Analog reading Stage level / setpoint Five-stage (S to S5) control, assignable up to five (5) binary/ relay output, i.e. Low-med-high-fault/fail-horn*, or low-low-med-med-high, or any other combinations (* = horn/audible alarm built-in and factory pre-configured to relay output R05 ) Four (4), for remote sensors Current and mean (average) value Field adjustable over full range, five (5) per analog input, assignable to current or mean (average) value - hysteresis/ switching differential Selectable for each sensor point Digital inputs Four (4), each can be individually assigned to any relay (R...R5). - application Remote audio/visual alarm reset or override function Relay outputs (R-R5) w/ status LEDs Five (5) SPDT, 8 A 4 VAC/VDC-50 VAC contact resistance 00 mω, max. (* ) BACnet Interface: NRTL Certification to UL STD 600- Pending - each stage level (S-S5) Assignable to any relay - sensor fail-safe Assignable to any stage level Time delay switching Selectable for make and brake of each sensor point (SP to SP4) 0-9,999 seconds Analog output Two () independent signal, 500 Ω max. load, selectable as low, high or averaging of sensor inputs Audible alarm 85 db (0 ft), enabled or disabled, selectable; assignable to stage level S, S, S3, S4 or S5 Alarm acknowledgment Menu-driven and system reset function for latched relays User Interface Keypad type Refer to section User Interface & Controller Touch buttons Six (6) Status LED s Red: Alarm Yellow: Fault (fail) Digital display Liquid Crystal Display (LCD), two lines, 6 characters per line, digit resolution, backlit - unit display Menu selectable, per sensor; ppm, %LEL, Vol%, F, %RH, %, ppk, C BACnet Interface, optional* Coupler module Communication Connector Interface Description Read status information via BACnet coupler and BACnet- Profile, BACnet-Services and BACnet BIBBs C5-BAC-98 (B) TCP/IP 0/00 Mbits/sec Ethernet RJ45 BACnet-Profile BACnet-Services Who-is (execute) I-am (initiate) ReadProperty WriteProperty Object types Version B., B. Environmental Permissible ambient controller - working temperature 3 F to 04 F (-5 C to 40 C) - storage temperature 3 F to 86 F (-5 C to 30 C) - humidity 5 to 95% RH, non-condensing Permissible ambient sensor/transmitter - working temperature 4 F to F (-0 C to 50 C) - intermitted temperature -4 F to F (-0 C to 50 C) - storage temperature 4 F to 86 F (5 C to 30 C) - humidity, continuous 5 to 90% RH, non-condensing - humidity, intermitted 0 to 99% RH, non-condensing - working pressure Atmospheric ± 0%

Specifications subject to change without notice. USA 4094 Page 3 of 6 SPECIFICATIONS Physical, Controller Enclosure (panel) - material Polycarbonate, impact resistance EN 500/IK08, flammability rating UL 94-5V - conformity UL Type, UL 508/UL 50 standards - color Light gray, smoked gray for cover - protection NEMA 4X (IP65) - installation Wall (surface) mounted Dimensions (H x W x D) - base 7.9 x 7.5 x 4. in. (00 x 90 x 05 mm) Cable entry 5 holes for / in. conduit, covered Wire connection Terminal blocks, Push-on connect and screw type for lead wire Wire size - input Min. AWG (0.34 mm ) Max. 6 AWG (.50 mm ) - output Min. 4 AWG (0.5 mm ) Max. 4 AWG (.50 mm ) Weight 4.5 lbs (.0 kg) Enclosure (panel) approval UL Listed, E75645 Physical, Sensor/Transmitter Enclosure, standard - material Polycarbonate, UL 94-HB, fire-retardant - conformity UL 50 - color Light gray - protection NEMA 4X (IP65) - installation Wall (surface) mounted, or single gang electrical box Dimensions (H x W x D) 5. x 3.3 x.95 in. (30 x 84 x 75 mm) Cable entry hole for / in. conduit for wall (surface) mounting and hole on back side of base plate for single gang electrical box mounting Wire connection Terminal blocks, screw type for lead wire Wire size Min. 4 AWG (0.5 mm²), Max. 4 AWG (.5 mm²) Wire distance Max. loop resistance 500 Ω (= wire resistance plus controller input resistance) Weight 0.6 lbs (0.5 kg) Enclosure approval UL Listed, E08470 CSA Certified, E08470 Approvals / Listings System NRTL Perf. Tested & Certified: - sensor/transmitter Conforms to ANSI/STD UL 075 - controller Conforms to ANSI/STD UL 07 - transmitter & controller City of Los Angeles CE VDI 053, air treatment systems for garages and tunnels EMC-Compliance 89/336/EWG, LVD 73/3/EWG Warranty Two years material and workmanship, months normal exposure for sensor element

Specifications subject to change without notice. USA 4094 Page 4 of 6 USER INTERFACE & CONTROLLER Keypad User Interface Alarm Power INTEC 3.06.3 :45am Exits programming; returns to the previous menu level. Main Page & Main Menu INTEC 3.06.3 :45am System Errors Stage Status Relay Status Sensor Readings Relay Setup SP Setup Data Logger System Setup Alarm - n Enters sub menus; saves parameter settings. Scrolls up & down within a menu; changes a value. Moves the cursor position. Fault System Operation All programming is made via the keypad user interface in combination with the display screen. Security is provided via two password levels. The lower level password (34) allows to override or to reset system status functions. The upper level password (900) allows all programming and override functions. Main Page Display After powered on, displays INTEC and Date/Time and changes to sensor reading display unless a system error occurs; then the error is displayed. Main Menu Displays headings of System Errors, Stage Status Relay Status, Sensor Readings, Relay Setup, SP (Sensor Point) Setup, Data Logger and System Setup. Sub Menu System Errors Displays errors, reset corrected errors, and historical error summary. Sub Menu Stage Status Displays status of each SP sensor point, stage level/setpoint exceeded. Sub Menu Relay Status Displays status and manual control of each output relay. Sub Menu Sensor Readings The current or average values are displayed for each SP sensor point with sensing type and engineering unit (ppm, %LEL, Vol%, F, %RH, %, ppk, C). Sub Menu Relay Setup Enter and/or change parameters of each relay. - Assign de-energized or energized normal operation - Select steady or flashing function - Select latching or non-latching mode - Select horn re-annunciation interval - Select digital input usage, and assign to any output relay - Set ON/OFF time delay Sub Menu SP Setup Enter and/or change parameters of each sensor point. - Activate/deactivate sensor point - Lock/unlock sensor point - Alarm on rising or falling value - Select sensor point type (gas, temperature, humidity) - Select full scale measuring range - Select sensor signal - Select stage/setpoint to 5 - Select hysteresis - Set delay ON/OFF time - Select current or average mode - Assign sensor point fault to stage level activation - Assign setpoint to 5 to any output relay - Assign to analog output Sub Menu Data Logger - Set data logger ON/OFF - Set sensor data logging ON/OFF - Set sensor data logging interval - Set alarm ( stage status ) logging ON/OFF - Set system error logging ON/OFF Sub Menu System Setup Enter and/or change system parameters. - Select service mode ON/OFF - Set next maintenance date - Select service phone number - Select averaging function, time and overlay, of any SP - Set date, time and time format - Change customer password - Select analog output function - Set failure relay - Select power ON time (alarm suppression) - Select appropriate hardware configuration - Assign relay multiplication

Specifications subject to change without notice. USA 4094 Page 5 of 6 FIELD WIRING CONFIGURATION Input Power (see ill. ) (see ill. ) X 3 4 5 6 7 8 9 0 3 4 5 Fault Binary - Relay Outputs R0 R0 R03 R04 R05 X INTEC Controls 0.4.3 0: 8am Alarm DIN Rail 3 4 5 6 7 8 X C5 Comm. Coupler Optional: BACnet X 3 4 (see ill. 6) X0 X 3 4 5 6 7 8 90 3 4 5 6 7 8 90 (see ill. 3) Sensor Inputs Digital Inputs Analog Outputs (see ill. 4) (see ill. 5) Horn Recommended Twisted, shielded wire for analog inputs (Shield to be terminated and connected only at the sensor/transmitter location) Grounded housing Caution: The non-metallic enclosure does not provide grounding between conduit connections. Use grounding bushings and jumper wires. The enclosure is to be mounted using the mounting holes located in the base external to the equipment cavity, or the equivalent. Input Power Supply (+) Com Terminal block X, -5%/+0%, 50/60 Hz Min wire size 6 AWG (.5 mm ) ill. The conduit hubs must be connected to the conduit before connected to the enclosure. When connecting conduit to the enclosure use only UL Listed or UL Recognized conduit hubs that have the same environmental type rating as the LGC-CO enclosure. C5 BACnet Communication Coupler, optional ill. 6 X 8 4 5 6 7 3 RJ45 Upwards BACnet communication to BAS

Specifications subject to change without notice. USA 4094 Page 6 of 6 FIELD WIRING CONFIGURATION (cont...) Binary - Relay Outputs R0 to R05 Built-in horn alarming*** factory wired, Fault (fail) alarming Stage-level control & alarming ( ) (+) *** #3 # # H 3 4 5 6 7 8 9 0 3 4 5 X *** Factory pre-configured horn and fault (fail-safe), can be reassigned/converted for remote control, stage-level #4 and/or #5 R0 R0 R03 R04 R05 Normal condition (factory default) D D D3 D4 D5 = Relay status LEDs D to D5 located below terminal connection of sensor inputs (X0) ill. Digital Inputs DI0 to DI04 ill. 3 Sensor Inputs SP0 to SP04 3 4 5 6 7 8 9 0 Analog Outputs AO0 to AO0 3 4 5 6 7 8 9 0 signal to remote control or BAS, selectable low, high or averaging of (4) analog (sensor) inputs, 500 Ω max. load The current signal is sourced by the LGC system ill. 6, see previous page X X (AO0) Com (AO0) Note: Sensor inputs other than AT Series Transmitters with a power consumption of greater than 55 ma requires a separate DC power supply. ill. 4 ill. 5 SP0 SP0/0- ( ) SP0 SP03 SP03/04- ( ) SP04 -wire sensor / transmitter 3 4 5 6 7 8 9 0 3-wire sensor / transmitter ( ) Remote CO sensor/transmitter SP X4 7 6 5 4 3 X0 Note: Twisted, shielded wire is recommended for -wire configurations. Shield should be grounded only at the controller. DO T ground shield at both ends! > 4 to 0 ma Signal < (+) 7 to 8 VDC