CARRIER REFRIGERATION EQUIPMENT AND PARTS

Similar documents
Low Profile Unit Cooler

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

KRAMER ELECTRIC DEFROST EVAPORATORS LPE - LVE - MSE - CSE - HSE - CED - KED INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS

MAC-120HE-01 Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

AIR-COOLED CONDENSERS Technical Guide

Slim Line KUC Unit Coolers 60Hz

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Split System Cooling Product Data

ARMSTRONG AIR HEAT PUMPS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Explosion-Proof Electric Unit Heaters

Cooling/Heat Pump Convertible Air Handlers

Split System Heat Pump Product Data

SECTION MORTUARY REFRIGERATORS

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Local Dealer:

Installation Manual CLIFC Fan & Coil Variable Speed

SECTION AIR CONDITIONING UNIT

CB29M Bulletin # February 1996

A. Section includes air conditioning units, controls and control panels.

Slim Contour Unit Cooler

TWE+TTA TWE+TWA T.R.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Split System Cooling Product Data

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Split System Cooling Product Data

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

Product Data. Split System Cooling F-EN. March 2015

Split System Heat Pump Product Data

Split System Cooling Product Data

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Horizontal Jet Pumps 1/3-1-1/2 HP

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

LOBOY 16 AIR CONDITIONERS

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Split System Cooling Product & Performance Data

University of Houston Master Construction Specifications Insert Project Name

Defining Quality. Building Comfort. Heating and Cooling Coils

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

REMOTE AIR-COOLED CONDENSERS. Installation and Maintenance Data. Models Bulletin H-IM-73A June 2000 Part Number

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

Why and How we Use Capacity Control

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

Split units TH with hermetic compressors

SECTION AIR COOLED WATER CHILLERS

Refrigerated Design Texas

catalog Single Package Vertical Air Conditioners and Heat Pumps

Split System Heat Pump Product Data

Compressors, Chillers & Condensers

SECTION HEAT PUMPS

HOSHIZAKI AMERICA, INC.

Split System Heat Pump Product Data

ROOF TOP MOUNTED Air Handler Specification

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Evaluate, Clean, and Tune Guidance

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Single Package Vertical Air Conditioners. Vert-I-Pak

How To Understand Evaporator

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

HP switch LP switch Discharge thermo Comp. Surface thermo

REFRIGERATED COMPRESSED AIR DRYERS

marine/bespoke split applications

SP H/M/L AFLR /1464/ /1469/ /22/ AFLR /8 1468/1209/ /6050/ /31/28 115

GCS

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Refrigeration System Installation & Operation Manual

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Application Engineering

"EC" Series Electric Humidifier

Chilled Water Fan Coil Unit

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Contents and Nomenclature

ECOCIAT. Domestic hot water heat recovery unit

Air-Cooled Condensers

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

Troubleshooting Your Refrigerator

Air Conditioners (Outdoor)

The Ultimate Truck Stock Motor

DESIGN STANDARDS SECTION

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

IV. Rear Mount System

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

Element D Services Heating, Ventilating, and Air Conditioning

CLASS B AIR CONDITIONING CONTRACTORS GENERAL TRADE KNOWLEDGE EXAMINATION CONTENT INFORMATION

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Commercial Gas Furnace Upflow

Transcription:

EVAPORATOR COILS CONDENSING UNITS 1/2 Through 80 HP COMPLETE REFRIGERATION PACKAGES AIR DEFROST ELECTRIC DEFROST HOT GAS DEFROST Ceiling Temp Low Height Unit Coolers SW Series Literature No. C 230.0 January, 2005 Flow Temp Low Velocity Unit Coolers LW Series Literature No. C 240.0 January, 2005 All Temp 2 b Low Profile Unit coolers CW Series Literature No. C 200.0 January, 2005 Inter Temp Medium Profile Unit Coolers Ultra Temp High Capacity Warehouse Unit Coolers Minicon - Air Cooled Cond. units 1/2 to 6 HP with Tecumseh hermetic and Carlyle semi-hermetic compressors FW Series Literature No. C 210.0 January, 2005 HW Series Literature No. C 220.0 January, 2005 CS Series - Air Cooled condensing units Literature No. C 300.1 January, 2006 MidLine - CM-Series - Air Cooled Condensing Units 3-15 HP With Carlyle compressors. Literature No. C 310.2,September, 2006 MaxLine - CL-Series - Air Cooled Condensing Units 20-80 HP With Carlyle compressors. Literature No. C 320, December, 2006 Plus parts for above mentioned units. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 94

Many of our units can be customized to meet specific job site requirements. Due to ongoing product development, product designs are subject to change without notice. ORDERING INFORMATION 1. Model Number 2. Type of defrost 3. Electrical characteristics voltage frequency and phase of motors. 4. Refrigerant type 5. Suction Temperature 6. Evaporator TD Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 95

Dual Air Discharge Unit Cooler SW Series APPLICATIONS The Dual Air Discharge unit cooler is designed for use in walk-in coolers and freezers with low headroom clearance. Its extra low height allows more product to be stored on shelves. The dual air flow design provides even temperatures throughout the box. SIZES There are twenty models available, ranging in capacity from 4,800 to 25,000 BTUH @ 10 TD. COIL The coil is constructed from seamless Copper tubes which are staggered and mechanically expanded into heavy gauge, corrugated, Aluminum fins, assuring maximum heat transfer. Optionally available with Copper or phenolic coated fins (phenolic fins are for air defrost only). HOUSING Rust free heavy gauge textured Aluminum is standard. Optionally available with white enamel coating. MOTORS / FANS Fan motors and blades can be easily accessed by lowering the hinged drain pan. Motors are life lubricated and are commonly in stock at most wholesale houses. ELECTRICAL Available in 115V, 208-230V & 460V/1. All components are factory wired to terminal strips and are UL & cul listed. DEFROST All models are available in air and electric defrost designs. Air defrost units are suitable for use in coolers down to 35 F. Electric defrost units are designed for use in rooms down to -10 F. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 96

Dual Air Discharge Unit Cooler SW Series AIR DEFROST / walk-in coolers 35 F and above MODEL NO. BTUH @ +25 F ST MOTOR AMPS DEFROST DEFROST AMPS 10 TD 15 TD CFM 115/1 230/1 WATTS 230/1 460/1 SWA38-75 7,500 11,250 1,455 3.3 1.7 SWA38-88 8,800 13,200 1,305 3.3 1.7 SWA38-98 9,800 14,700 1,200 3.3 1.7 SWA48-112 11,200 16,800 2,120 4.4 2.2 SWA48-130 SWA58-162 13,000 16,200 19,500 24,300 1,920 2,320 4.4 5.5 2.2 2.8 SWA48-150 SWA48-210 15,000 21,000 22,500 31,500 1,760 1,820 4.4 4.4 2.2 2.2 NOT AVAILABLE SWA58-230 23,000 34,500 2,650 5.5 2.8 SWA68-250 25,000 37,500 2,970 6.6 3.3 IN SWA36-64 6,400 9,600 1,560 3.3 1.7 SWA36-82 8,200 12,300 1,425 3.3 1.7 ELECTRIC SWA36-93 9,300 13,950 1,305 3.3 1.7 SWA46-100 10,000 15,000 2,160 4.4 2.2 DEFROST SWA46-123 12,300 18,450 2,040 4.4 2.2 SWA46-140 14,000 21,000 1,920 4.4 2.2 SWA56-157 15,700 23,500 2,360 5.5 2.8 SWA46-190 19,000 28,500 1,940 4.4 2.2 SWA56-208 20,800 31,200 2,850 5.5 2.8 SWA66-232 23,200 34,800 3,150 6.6 3.3 Standard voltage supplied on SWA models is 115/1/60 8 FPI 6 FPI ELECTRIC DEFROST / walk in coolers and freezers below +34 F MODEL NO. BTUH @ 10 TD MOTOR AMPS DEFROST DEFROST AMPS -20 ST +20 ST CFM 115/1 230/1 WATTS 230/1 460/1 SWE36-53 5,300 6,360 1,440 3.3 1.7 2070 9.0 4.5 SWE36-62 6,200 7,440 1,290 3.3 1.7 2070 9.0 4.5 SWE36-69 6,900 8,200 1,245 3.3 1.7 2070 9.0 4.5 SWE46-77 7,700 9,240 2,075 4.4 2.2 2990 13.0 6.5 SWE46-90 9,000 10,800 1,860 4.4 2.2 2990 13.0 6.5 SWE46-100 10,000 12,000 1,740 4.4 2.2 2990 13.0 6.5 SWE56-125 12,500 15,000 2,160 5.5 2.8 3910 17.0 8.5 SWE46-140 14,000 16,800 1,820 4.4 2.2 3910 17.0 8.5 SWE56-160 16,000 19,200 2,550 5.5 2.8 3910 17.0 8.5 SWE66-218 21,800 23,200 3,000 6.6 3.3 3910 17.0 8.5 SWE34-48 4,800 5,760 1,500 3.3 1.7 2070 9.0 4.5 SWE34-58 5,800 6,960 1,395 3.3 1.7 2070 9.0 4.5 SWE34-65 6,500 7,800 1,350 3.3 1.7 2070 9.0 4.5 SWE44-72 7,200 8,640 2,120 4.4 2.2 2990 13.0 6.5 SWE44-84 8,400 10,080 1,980 4.4 2.2 2990 13.0 6.5 SWE44-95 9,500 11,400 1,900 4.4 2.2 2990 13.0 6.5 SWE54-115 11,500 13,800 2,280 5.5 2.8 3910 17.0 8.5 SWE44-128 12,800 15,360 1,940 4.4 2.2 3910 17.0 8.5 SWE54-145 14,500 17,400 2,650 5.5 2.8 3910 17.0 8.5 SWE64-173 17,300 20,760 3,080 6.6 3.3 3910 17.0 8.5 Standard voltage supplied on SWE models is 208-230/1/60 6 FPI 4 FPI Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 97

Dual Air Discharge Unit Cooler SW Series AIR DEFROST Models 8 FPI 6 FPI MODEL DIMENSIONS(in) TXV CONNECTIONS(in) SHIP WT. NUMBER L W H A B TYPE LIQ. (ODS) SUCT. (ODS) (lbs) SWA38-75 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 95 SWA38-88 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 100 SWA38-98 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 105 SWA48-112 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 125 SWA48-130 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 130 SWA48-150 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 135 SWA58-162 106-1/2 28-3/4 8-3/4 48 48 EXT 1/2 7/8 150 SWA48-210 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 155 SWA58-230 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 165 SWA68-250 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 1-1/8 185 SWA36-64 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 90 SWA36-82 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 95 SWA36-93 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 100 SWA46-100 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 120 SWA46-123 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 125 SWA46-140 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 130 SWA56-157 106-1/2 28-3/4 8-3/4 48 48 EXT 1/2 7/8 145 SWA46-190 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 150 SWA56-208 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 160 SWA66-232 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 1-1/8 180 ELECTRIC DEFROST Models 6 FPI 4 FPI MODEL DIMENSIONS(in) TXV CONNECTIONS(in) SHIP WT. NUMBER L W H A B TYPE LIQ. (ODS) SUCT. (ODS) (lbs) SWE36-53 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 95 SWE36-62 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 100 SWE36-69 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 105 SWE46-77 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 125 SWE46-90 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 130 SWE46-100 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 135 SWE56-125 106-1/2 28-3/4 8-3/4 48 48 EXT 1/2 7/8 150 SWE46-140 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 155 SWE56-160 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 165 SWE66-218 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 1-1/8 185 SWE34-48 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 90 SWE34-58 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 95 SWE34-65 58-1/2 28-3/4 8 24 24 EXT 1/2 5/8 100 SWE44-72 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 120 SWE44-84 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 125 SWE44-95 82-1/2 28-3/4 8-3/4 36 36 EXT 1/2 7/8 130 SWE54-115 106-1/2 28-3/4 8-3/4 48 48 EXT 1/2 7/8 145 SWE44-128 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 150 SWE54-145 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 7/8 160 SWE64-173 106-1/2 28-3/4 10-1/4 48 48 EXT 1/2 1-1/8 180 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 98

Low Velocity Discharge Unit Cooler LW Series APPLICATIONS The Low Velocity Discharge unit coolers are ideally suited for meat cutting, holding and packaging rooms as well as produce storage and florist boxes. SIZES There are eight models available, ranging in capacity from 6,700 to 37,000 BTUH@ 10 TD. HOUSING Rust free heavy gauge textured Aluminum is standard. Optionally available with white enamel coating. COIL Seamless copper tubes are staggered and mechanically expanded into heavy gauge corrugated Aluminum fins assuring maximum heat transfer. Optionally available with copper or phenolic coated fins. MOTORS / FANS Fan motors and blades can be easily accessed by lowering the hinged drain pan. Motors are life lubricated and are commonly in stock at most wholesale houses. ELECTRICAL Available in 115V and 208/230V. All components are factory wired to terminal strips and are UL and cul listed DEFROST All models are available in air, electric and hot gas defrost designs. Air defrost units are suitable for use in coolers down to 35 F. Electric, Hot Gas Re-Evap and Hot Gas Reverse Cycle coils are designed for use in rooms down to 28 F. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 99

Low Velocity Discharge Unit Cooler LW Series PERFORMANCE AND ELECTRICAL DATA CAPACITY (Btu/hr) MOTOR ELECTRIC DEFROST MODEL CFM AMPS AMPS 10 F TD 15 F TD 20 F TD QTY NO 115V 230/1 WATTS 230V/1 230V/3 460V/1 LW*26-67 6,700 10,050 13,400 1050 2 1.2.6 3940 17.2 14.8 8.6 LW*36-100 10,000 15,000 20,000 1220 3 1.8.9 5960 26.0 22.5 13.0 LW*36-135 13,500 20,250 27,000 1670 3 3.3 1.65 5960 26.0 22.5 13.0 LW*36-160 16,000 24,000 32,000 1820 3 3.3 1.65 5960 26.0 22.5 13.0 LW*46-180 18,000 27,000 36,000 2230 4 4.4 2.2 8060 35.0 21.3 17.5 LW*46-220 22,000 33,000 44,000 2420 4 4.4 2.2 8060 35.0 21.3 17.5 LW*46-265 26,500 37,950 53,000 2420 4 4.4 2.2 8060 35.0 21.3 17.5 LW*56-370 37,000 55,500 74,000 2830 5 5.5 3.3 9920 43.1 28.5 21.6 ORDERING INFORMATION REQUIRED: 1. Model number 2. Type of defrost 3. Electrical characteristics 4. Refrigerant type 5. Suction temperature 6. Evaporator TD NOTE: Air defrost models are suitable for +35 F room temperature and above. Electric and Hot Gas defrost suitable for +28 F room temperature and above. PHYSICAL DATA MODEL DIMENSIONS (in) MODEL NOMENCLATURE: SHIP WT. (lbs) CONNECTIONS (in.)1 NO A B C D W LIQUID SUCTION DRAIN LW*26-67 48 7-1/2 6-1/4 8-1/2 58-1/2 1/2 F.N. 7/8 OD 3/4 MPT 155 LW*36-100 36 7-1/2 6-1/4 8-1/2 82-1/2 1/2 F.N. 7/8 OD 3/4 MPT 205 LW*36-135 36 10-1/2 9-3/4 12 82-1/2 1/2 F.N. 1-1/8 OD 3/4 MPT 265 LW*36-160 36 10-1/2 9-3/4 12 82-1/2 1/2 F.N. 1-1/8 OD 3/4 MPT 285 LW*46-180 48 10-1/2 9-3/4 12 106-1/2 1/2 F.N. 1-1/8 OD 3/4 MPT 325 LW*46-220 48 10-1/2 9-3/4 12 106-1/2 1/2 F.N. 1-1/8 OD 3/4 MPT 340 LW*46-265 48 13-1/2 12-3/4 12 106-1/2 1/2 F.N. 1-1/8 OD 3/4 MPT 370 LW*56-370 60 13-1/2 12-3/4 15 130-1/2 1/2 F.N. 1-1/8 OD 3/4 MPT 490 1 - All models require externally equalized TXV. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 100

Low Profile Unit Cooler CW Series AIR DEFROST - 3,900 to 39,000 BTUH ELECTRIC DEFROST - 3,600 to 28,000 BTUH HOT GAS DEFROST - 3,600 to 28,000 BTUH SMALL TO MEDIUM WALK-INS COOLERS & FREEZER APPLICATIONS FEATURES: The Carrier Low Profile is the original low profile unit cooler that has established an industry standard as being the all purpose design for walk-in coolers, freezers and other applications. They feature an air draw-through design offering air, electric and hot gas defrost models. SIZES There are 35 sizes available with 3,700 to 39,000 BTUH at a 10 TD ranging from 740 to 4,980 cfm. One through six fan models are available. HOUSING Rust-free, heavy gauge, textured Aluminum casing is light weight yet durable. Each fan section is baffled to prevent short cycling of the air. The unit is designed to mount flush to the ceiling and meets all NSF requirements. Slotted hangers are provided for easy installation. Drain fittings are installed in the horizontal position to gain more usable headroom in low ceiling applications. The end panels now are hinged to open up out for easy access to both the piping and electrical ends. Optional expansion valves can be conveniently installed inside the cabinet. COIL Seamless Copper tubes are staggered and mechanically expanded into corrugated Aluminum fins and heavy gauge tube sheets to achieve maximum heat transfer and strength. Die formed fin collars provide even fin spacing. Fin spacings available are 4, 6, and 8 fins per inch. Sweat connections are standard on all models and optional field installed flare connection kits are available at no extra charge. MOTORS All motors are 1/20 HP, permanently lubricated, ball bearing, with thermal overload protection. Available in 115V, 208/230V and optional 460V, single Phase. Optional high efficiency PSC motors are available in 115V and 230V. FANS Heavy duty 12 Aluminum fans are balanced to provide vibration-free operation. Our new low throw black plastic fan guards have an improved air pattern. The optional epoxy resin high throw fan guard moves air up to 50 feet. AIR DEFROST All models with the prefix CWA are designed for use in coolers of 35 F and warmer. Complete air defrost systems for off-cycle or timed air defrost are available from Carrier. ELECTRICAL Available in 115V, 208/230V, and 460V (see page 4). All components are factory wired to convenient screw-type terminal strips. A large compartment is supplied internal to the unit for all electrical components and is easily accessible by removing the end panel. All models are UL & cul listed. ELECTRIC DEFROST Available on all models with the prefix CWE. Designed for use where electric heat is used to defrost. Placement of the heaters internal to the coil allows for an extremely rapid and efficient defrost. This arrangement enables the heat to be conducted through the fins from the center out for an even defrost pattern. All heaters are wired to a terminal strip to allow a quick field change-over from single phase to three phase, 230V to 460V and vice versa. A lower heater is installed close to the drain pan for fast, reliable drainage. A defrost termination thermostat (DT) terminates the defrost cycle when the temperature is satisfied. A heater safety thermostat is installed to prevent heaters from overheating above 75 F in case of DT failure. All heaters are flexible and can be easily replaced within 12 inches of the end of the units. A fan delay thermostat is supplied to allow the warm coil to cool after a defrost cycle prior to the fans turning on. Complete electric defrost refrigeration systems are available from Carrier. HOT GAS DEFROST Two types available - Re-Evap models with the prefix CWH and reverse cycle with the prefix CWG. All models include a fixed DTFD factory wired and a hot gas drain pan circuit to defrost the drain pan. On all Hot Gas models, the drain fitting is located on the left-hand rear of the unit when facing the fan guards. Re-evap models include a Heat Exchanger-Re-Evaporator shipped together with the unit for field installation. Complete Re-Evap Refrigeration Systems are available from Carrier. Contact factory for piping information. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 101

AIR DEFROST / SPECIFICATIONS 8 FPI 6 FPI 4 FPI BTUH Capacity @ Total Fan Motor AMPS - 1 Phase Total Fan Motor AMPS 1 Phase 25 F ST CFM Standard Motor Optional PSC Motor MODEL NO 10 TD 12 TD 115V 230V 460V 115V 230V CWA18-41 4,100 4,900 800 2.0 1.0 0.5 1.0 0.5 CWA18-53 5,300 6,400 770 2.0 1.0 0.5 1.0 0.5 CWA18-66 6,600 7,900 740 2.0 1.0 0.5 1.0 0.5 CWA28-76 7,600 9,100 1,460 4.0 2.0 1.0 2.0 1.0 CWA28-97 9,700 11,600 1,420 4.0 2.0 1.0 2.0 1.0 CWA28-106 10,600 12,700 1,540 4.0 2.0 1.0 2.0 1.0 CWA28-122 12,200 14,600 1,380 4.0 2.0 1.0 2.0 1.0 CWA28-134 13,400 16,100 1,480 4.0 2.0 1.0 2.0 1.0 CWA28-160 16,000 19,200 2,310 6.0 3.0 1.5 3.0 1.5 CWA38-195 19,500 23,400 2,220 6.0 3.0 1.5 3.0 1.5 CWA48-212 21,200 25,400 3,080 8.0 4.0 2.0 4.0 2.0 CWA48-264 26,400 31,700 2,960 8.0 4.0 2.0 4.0 2.0 CWA58-275 27,500 33,000 3,850 10.0 5.0 2.5 5.0 2.5 CWA68-318 31,800 38,200 4,620 12.0 6.0 3.0 6.0 3.0 CWA68-390 39,000 46,800 4,440 12.0 6.0 3.0 6.0 3.0 CWA16-39 3,900 4,700 830 2.0 1.0 0.5 1.0 0.5 CWA16-48 4,800 5,800 800 2.0 1.0 0.5 1.0 0.5 CWA16-58 5,800 7,000 780 2.0 1.0 0.5 1.0 0.5 CWA26-70 7,000 8,400 1,540 4.0 2.0 1.0 2.0 1.0 CWA26-87 8,700 10,400 1,500 4.0 2.0 1.0 2.0 1.0 CWA26-115 11,500 13,800 1,560 4.0 2.0 1.0 2.0 1.0 CWA36-145 14,500 17,400 2,400 6.0 3.0 1.5 3.0 1.5 CWA36-170 17,000 20,400 2,340 6.0 3.0 1.5 3.0 1.5 CWA46-192 19,200 23,000 3,200 8.0 4.0 2.0 4.0 2.0 CWA46-230 23,000 27,600 3,120 8.0 4.0 2.0 4.0 2.0 CWA56-245 24,500 29,400 4,000 10.0 5.0 2.5 5.0 2.5 CWA66-295 29,500 35,400 4,800 12.0 6.0 3.0 6.0 3.0 CWA66-345 34,500 41,400 4,680 12.0 6.0 3.0 6.0 3.0 CWA14-42 4,200 5,000 830 2.0 1.0 0.5 1.0 0.5 CWA24-84 8,400 10,100 1,660 4.0 2.0 1.0 2.0 1.0 CWA24-105 10,500 12,600 1,620 4.0 2.0 1.0 2.0 1.0 CWA34-130 13,000 15,600 2,490 6.0 3.0 1.5 3.0 1.5 CWA44-170 17,000 20,400 3,320 8.0 4.0 2.0 4.0 2.0 CWA54-215 21,500 25,800 4,150 10.0 5.0 2.5 5.0 2.5 CWA64-255 25 500 30 600 980 12.0 6.0 3.0 6.0 3.0 ORDERING INFORMATION It is vital that the information listed below is given with each evaporator order. Orders without this information may be delayed. Evaporators with options such as solenoid and expansion valves will not be processed until all the required information is given. 1. Model Number 2. Voltage, frequency and phase of motors and heaters (when applicable) 3. Refrigerant Type 4. Evaporator Temperature 5. Evaporator T.D. OPTIONAL FEATURES High efficiency PSC fan motors 460 volt motors and heaters Coated Aluminum fins or Copper Fins Baked white enamel housing Epoxy resin high throw guards for up to 50 ft. Reheat kits (not UL listed Factory mounted expansion valves Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 102

ELECTRIC DEFROST / SPECIFICATIONS BTUH Capacity @ 10 TD Evaporator 6 FPI 4 FPI Temperature MODEL NO -30-20 -10 +20 CFM Motor Amps¹ Heater Amps² Standard PSC 208/230V 460V Watts 230V 460V 230V 1 PH 3 PH 1 PH CWE16-36 3,400 3,600 3,700 3,900 830 1.0 0.5 0.5 4.4 2.6 2.2 1,000 CWE16-41 3,900 4,100 4,300 4,800 800 1.0 0.5 0.5 4.4 2.6 2.2 1,000 CWE16-46 4,400 4,600 4,800 5,800 780 1.0 0.5 0.5 4.4 2.6 2.2 1,000 CWE26-60 5,700 6,000 6,200 7,000 1,540 2.0 1.0 1.0 7.0 6.0 3.5 1,600 CWE26-75 7,100 7,500 7,800 8,700 1,500 2.0 1.0 1.0 7.0 6.0 3.5 1,600 CWE26-92 8,700 9,200 9,600 11,500 1,560 2.0 1.0 1.0 8.7 7.5 4.4 2,000 CWE36-120 11,400 12,000 12,500 14,500 2,400 3.0 1.5 1.5 13.0 11.3 6.4 3,000 CWE36-140 13,300 14,000 14,600 17,000 2,340 3.0 1.5 1.5 13.0 11.3 6.4 3,000 CWE46-164 15,000 16,400 17,100 19,200 3,200 4.0 2.0 2.0 17.4 15.1 8.7 4,000 CWE46-185 17,600 18,500 19,200 23,000 3,120 4.0 2.0 2.0 17.4 15.1 8.7 4,000 CWE56-210 20,000 21,000 21,800 24,500 4,000 5.0 2.5 2.5 18.8 10.9 5,000 CWE66-245 23,300 24,500 25,500 29,500 4,800 6.0 3.0 3.0 22.6 13.0 6,000 CWE66-280 26,600 28,000 29,100 34,500 4,680 6.0 3.0 3.0 22.6 13.0 6,000 CWE14-37 3,500 3,700 3,800 4,200 830 1.0 0.5 0.5 4.4 2.6 2.2 1,000 CWE24-72 6,800 7,200 7,500 8,400 1,660 2.0 1.0 1.0 8.7 7.5 4.4 2,000 CWE24-85 8,100 8,500 8,800 10,500 1,620 2.0 1.0 1.0 8.7 7.5 4.4 2,000 CWE34-105 10,000 10,500 10,900 13,000 2,490 3.0 1.5 1.5 13.0 11.3 6.4 3,000 CWE44-140 13,300 14,000 14,600 17,000 3,320 4.0 2.0 2.0 17.4 15.1 8.7 4,000 CWE54-180 17,100 18,000 18,700 21,500 4,150 5.0 2.5 2.5 18.8 10.9 5,000 CWE64-215 20,400 21,500 22,400 25,500 4,980 6.0 3.0 3.0 22.6 13.0 6,000 (1) All fan motors are wired for single phase. Standard motors are shaded pole. High efficiency PSC (Permanent Split Capacitor) motors are optional. (2) For 280/230 volt models, heaters are wired as standard for single phase on 1 through 4 fan models. 5 and 6 fan models are wired 3 phase. 460 Volt models are only available in single phase and are compatible with all 3 phase systems. HOT GAS DEFROST / SPECIFICATIONS 6 FPI 4 FPI Model Number BTUH Capacity @ 10 TD Evaporator Temperature Re-Evap Rev Cycle -30-20 -10 +20 CFM Fan Motor Amps¹ Standard PSC 115V 230V 460V 115V 230V Re-Evap HEA Unmtd CWH16-36 CWG16-36 3,400 3,600 3,700 3,900 830 1.0 1.0 0.5 1.0 0.5 1A CWH16-41 CWG16-41 3,900 4,100 4,300 4,800 800 1.0 1.0 0.5 1.0 0.5 1A CWH16-46 CWG16-46 4,400 4,600 4,800 5,800 780 1.0 1.0 0.5 1.0 0.5 1A CWH26-60 CWG26-60 5,700 6,000 6,200 7,000 1,540 2.0 2.0 1.0 2.0 1.0 2A CWH26-75 CWG26-75 7,100 7,500 7,800 8,700 1,500 2.0 2.0 1.0 2.0 1.0 2A CWH26-92 CWG26-92 8,700 9,200 9,600 11,500 1,560 2.0 2.0 1.0 2.0 1.0 2A CWH36-120 CWG36-120 11,400 12,000 12,500 14,500 2,400 3.0 3.0 1.5 3.0 1.5 3A CWH36-140 CWG36-140 13,300 14,000 14,600 17,000 2,340 3.0 3.0 1.5 3.0 1.5 3A CWH46-164 CWG46-164 15,000 16,400 17,100 19,200 3,200 4.0 4.0 2.0 4.0 2.0 3A CWH46-185 CWG46-185 17,600 18,500 19,200 23,000 3,120 4.0 4.0 2.0 4.0 2.0 3A CWH56-210 CWG56-210 20,000 21,000 21,800 24,500 4,000 5.0 5.0 2.5 5.0 2.5 3A CWH66-245 CWG66-245 23,300 24,500 25,500 29,500 4,800 6.0 6.0 3.0 6.0 3.0 4A CWH66-280 CWG66-280 26,600 28,000 29,100 34,500 4,680 6.0 6.0 3.0 6.0 3.0 4A CWH14-37 CWG14-37 3,500 3,700 3,800 4,200 830 1.0 1.0 0.5 1.0 0.5 1A CWH24-72 CWG24-72 6,800 7,200 7,500 8,400 1,660 2.0 2.0 1.0 2.0 1.0 2A CWH24-85 CWG24-85 8,100 8,500 8,800 10,500 1,620 2.0 2.0 1.0 2.0 1.0 2A CWH34-105 CWG34-105 10,000 10,500 10,900 13,000 2,490 3.0 3.0 1.5 3.0 1.5 2A CWH44-140 CWG44-140 13,300 14,000 14,600 17,000 3,320 4.0 4.0 2.0 4.0 2.0 3A CWH54-180 CWG54-180 17,100 18,000 18,700 21,500 4,150 5.0 5.0 2.5 5.0 2.5 3A CWH64-215 CWG64-215 20,400 21,500 22,400 25 500 4,980 6.0 6.0 3.0 6.0 3.0 3A (1) All fan Motors are wired for single phase Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 103

PHYSICAL DATA Models Refrigerant Connections Dimensions No. (Inches) CWA CW E/H/G TXV TYPE All Liquid CWA Suction CW E/H/G Suction HG Of Hangers A B C W 18-41 - EXT ½ ODS 5/8 0DS - - 2 19 - - 27-1/2 43 18-43 - EXT 1/2 5/8 - - 2 19 - - 27-1/2 46 18-66 - EXT 1/2 5/8 - - 2 19 - - 27-1/2 50 28-76 - EXT 1/2 5/8 - - 2 33 - - 41-1/2 64 28-97 - EXT 1/2 7/8 - - 2 33 - - 41-1/2 69 28-106 - EXT 1/2 7/8 - - 2 37 - - 45-1/2 71 28-122 - EXT 1/2 7/8 - - 2 33 - - 41-1/2 74 28-134 - EXT 1/2 7/8 - - 2 37 - - 45-1/2 77 38-160 - EXT 1/2 1-1/8 - - 2 55 - - 63-1/2 110 38-195 - EXT 1/2 1-1/8 - - 2 55 - - 63-1/2 120 48-212 - EXT 1/2 1-1/8 - - 3 36-1/2 36-1/2-81-1/2 145 48-264 - EXT 1/2 1-1/8 - - 3 36-1/2 36-1/2-81-1/2 160 58-275 - EXT 1/2 1-1/8 - - 3 54-1/2 36-1/2-99-1/2 230 68-318 - EXT 1/2 1-1/8 - - 4 36-1/2 36 36-1/2 117-1/2 255 68-390 - EXT 1/2 1-1/8 - - 4 36-1/2 36 36-1/2 117-1/2 275 16-39 16-36 EXT ½ ODS 5/8 0DS 5/8 0DS 5/8 0DS 19 - - 27-1/2 41 16-48 16-41 EXT 1/2 5/8 5/8 5/8 2 19 - - 27-1/2 44 16-58 16-46 EXT 1/2 5/8 5/8 5/8 2 19 - - 27-1/2 47 26-70 26-60 EXT 1/2 5/8 5/8 5/8 2 33 - - 41-1/2 61 26-87 26-75 EXT 1/2 7/8 7/8 5/8 2 33 - - 41-1/2 67 26-115 26-92 EXT 1/2 7/8 7/8 5/8 2 37 - - 45-1/2 74 36-145 36-120 EXT 1/2 7/8 7/8 5/8 2 55 - - 63-1/2 105 36-170 36-140 EXT 1/2 1-1/8 1-1/8 5/8 2 55 - - 63-1/2 115 46-192 46-164 EXT 1/2 1-1/8 1-1/8 5/8 3 36-1/2 36-1/2-81-1/2 140 46-230 46-185 EXT 1/2 1-1/8 1-1/8 5/8 3 36-1/2 36-1/2-81-1/2 155 56-245 56-210 EXT 1/2 1-1/8 1-1/8 5/8 3 36-1/2 36-1/2-99-1/2 225 66-295 66-245 EXT 1/2 1-1/8 1-1/8 5/8 4 36-1/2 36 36-1/2 117-1/2 250 66-345 66-280 EXT 1/2 1-1/8 1-1/8 5/8 4 36-1/2 36 36-1/2 117-1/2 270 14-42 14-37 EXT ½ ODS 5/8 0DS 5/8 0DS 5/8 0DS 2 19 - - 27-1/2 42 24-84 24-72 EXT 1/2 5/8 5/8 5/8 2 37 - - 45-1/2 67 24-105 24-85 EXT 1/2 5/8 5/8 5/8 2 37 - - 45-1/2 72 34-130 34-105 EXT 1/2 5/8 5/8 5/8 2 55 - - 63-1/2 100 44-170 44-140 EXT 1/2 7/8 7/8 5/8 3 36-1/2 36-1/2 36-1/2 81-1/2 135 54-215 54-180 EXT 1/2 1-1/8 1-1/8 5/8 3 54-1/2 36-1/2 36-1/2 99-1/2 220 64-255 64-215 EXT 1/2 1-1/8 1-1/8 5/8 4 36-1/2 36 36 117-1/2 245 Optional Extended Flare Kit available upon request for field installation. Hot Gas connections only apply to the CWH models. INSTALLATION NOTES: (1) Install 12 away from back wall. (2) Drain connection on CWA and CWE units are centered on drain pan; and on the left end (facing air discharge) on CWH and CWG units. (3) For long air throw requirements, specify high throw fan guard. (4) Unit height at drain end of hot gas models is as follows: 1,2, and 3 fan models = 15-7/8, 4,5, and 6 fan models = 16-1/4. Ship Wt. (lbs.) Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 104

Medium Profile Unit Cooler FW Series AIR DEFROST 12,600 to 69,000 BTUH ELECTRIC DEFROST 10,500 to 52,000 BTUH HOT GAS DEFROST 10,500 to 52,000 BTUH MEDIUM TO LARGE WALK-IINS COOLER & FREEZER APPLICATIONS FEATURES APPLICATIONS Medium Profile unit coolers are ideally suited for a wide range of coolers and freezers. FWA models are designed for use in coolers above 35 F. FWE, FWG, and FWH units are suited for 35 F coolers, when mechanical defrosts are required, as well as for freezers with temperatures ranging down to -30 F. SIZES There are 37 models offered, with capacities from 10,500 BTUH up to 69,000 BTUH @ 10 TD. Air flow ranges from 3,320 CFM to 9,130 CFM. HOUSING Each unit is constructed with a rust-free, heavy gauge, textured, Aluminum housing which is light weight yet extremely durable. Air and electric defrost models have hinged drain pans to allow for convenient servicing and maintenance (Hot Gas drain pans are not hinged). Slotted hangers are provided on all units for fast installation. COIL Seamless Copper tubes are staggered and mechanically expanded into heavy gauge corrugated Aluminum fins to assure maximum heat transfer. Die formed fin collars are provided for accurate fin spacing. Heavy gauge hangers are fastened directly to the tube sheet of the coil to provide high structural strength. REFRIGERATION Medium Profile unit coolers are designed for most refrigerants including, R-22, R-404A, R-134a, R-502 and R-507. Please specify system refrigerant requirements when ordering. A separate compartment is provided for all refrigerant connections which allows ample room for internal mounting of expansion valves. Medium Profile can also be used with chilled water or glycol solutions, contact factory for selection. FANS Powerful heavy duty Aluminum fans are individually balanced to provide vibration free operation. WIRE FAN GUARDS Standard heavy gauge wire fan guards are epoxy coated for corrosion resistance. Optional air straighteners are available for increased air throw when required. MOTORS All motors are high efficiency PSC, ball bearing type, life lubricated and thermally protected. Medium Profile unit coolers use either 1/8 HP, 1050 rpm or 1/3 HP, 1075 rpm motors. ELECTRICAL Available in 115V/1, 208/230/1, 208/230/3, 460/1 or 460/3. Inter-Temps can also be operated on 220/1/50, 220/3/50, 380/1/50 and 380/3/50 power. All components are factory wired to convenient screw type terminal blocks. A large compartment is supplied for all electrical components and is easily accessible by removing the end panel. AIR DEFROST Available on FWA series only, for use in coolers at +35 F and above. Complete air defrost systems are available from Carrier. ELECTRIC DEFROST These units are available as FWE models. The placement of heaters within the refrigeration coil allows for a more efficient and rapid defrost cycle than other designs. This arrangement enables the energy from the heaters to be conducted from the center of the core out, providing an even defrost pattern. All heaters are factory installed and wired to screw type terminal blocks, allowing for quick field hook up or change over from 1 to 3 phase with the installation of jumper wires. Separate, fixed defrost termination; fan delay and heater safety controls are factory mounted for optimum performance of each control function. Drain pans are heated for fast, reliable drainage. Timer and contactors are available as options. Complete electric defrost systems are available from Carrier. HOT GAS RE-EVAP DEFROST Available on all but the FWA models. These units include separate fixed defrost termination and fan delay controls which are factory mounted for optimum performance of each control function. A hot gas drain pan circuit is provided, thus eliminating the need for electric heat and additional wiring. A heat exchanger /re-evaporator is supplied with every unit. HOT GAS REVERSE CYCLE DEFROST Available on all but the FWA models. These units include separate fixed defrost termination and fan delay controls which are factory mounted for optimum performance of each control function. A hot gas drain pan circuit is provided, thus eliminating the need for electric heat and additional wiring. This unit is also used for Alternating Evaporator System. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 105

Medium Profile Unit Cooler FW Series OPTIONS Copper fins Coated fins (air and hot gas defrost models only) Galvanized steel housing Insulated drain pans Custom circuiting for chilled water or glycol applications High throw fan guards (air straighteners) Reheat kit. Adjustable DTFD Contact factory for other requirements Nomenclature AIR THROW Air throw is greatly affected by installation variables. Optimum air throw is obtained by high ceiling with no interference from beams, or return air restrictions. Medium Profile unit coolers will throw air up to 50 feet under ideal conditions, 60 to 70 feet with air straighteners. Performance Data F R E 4 E F Z P E I R MODEL CAPACITY BTUH @ 10 TD (R404A, R22) NUMBER CFM -30 F -20 F -10 F +10 F +25 F FW*24-105 3940 10000 10500 11100 11700 12600 FW*24-140 3620 13400 14000 14600 15900 16900 FW*34-175 5750 16700 17500 18200 19800 22400 FW*34-230 5930 21900 23000 24000 26000 28700 FW*24-325 5430 31000 32500 33800 36800 40100 FW*34-390 8990 37100 39000 40600 44100 46000 FW*34-510 8150 48600 51000 53100 57700 58500 MODEL CAPACITY BTUH @ 10 TD (R404A, R22) NUMBER CFM -30 F -20 F -10 F +10 F +25 F F FW*26-130 3780 12400 13000 13600 14200 15000 R FW*26-150 3470 14300 15000 15600 17000 19100 E 6 FW*36-185 5510 17600 18500 19300 21000 24000 E F FW*26-270 5720 25700 27000 28100 29200 30500 Z P FW*26-320 5480 30500 32000 33300 35600 37000 E I R FW*36-385 9130 36700 38500 40100 43600 49000 FW*36-460 9090 43800 46000 47900 52000 54800 FW*36-520 8190 49500 52000 54100 58800 62000 * E = Electric defrost H=Hot gas defrost-re evap G = Hot gas defrost-reverse cycle C O 4 O F L P E I R MODEL BTUH MODEL BTUH MODEL CFM BTUH NUMBER CFM +25 F NUMBER CFM +25 F NUMBER +25 F FWA24-126 3830 12600 FWA26-145 3680 14500 FWA28-151 3530 15100 FWA24-169 3620 16900 C FWA26-191 3470 19100 C FWA28-210 3320 21000 FWA34-224 5750 22400 O 6 FWA36-240 5510 24000 O 8 FWA38-260 5300 26000 FWA34-287 5200 28700 O F FWA36-305 4960 30500 O F FWA38-320 4750 32000 FWA24-340 5710 34000 L P FWA26-370 5460 37000 L P FWA28-410 5250 41000 E I E I FWA24-395 5430 39500 FWA36-415 8620 41500 FWA28-450 5020 45000 R R FWA34-465 8990 46500 FWA36-490 8580 49000 FWA38-540 8250 54000 FWA34-585 8140 58500 FWA36-620 7770 62000 FWA38-690 7470 69000 For 50 Hz applications, multiply BTU/H capacity by.94 correction factor. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 106

ELECTRICAL DATA. F R 4 E E F Z P E I R F R 6 E E F Z P E I R TOTAL MOTOR AMPS 60 HZ ELECTRIC DEFROST AMPERAGE RATINGS @60 HZ 208/230 460 V MODEL 115 V V 1 PH 208 V 230 V 460 V NUMBER 1 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH WATTS FW*24-105 4 1.8 0.9 18.3 10.5 20.3 11.7 10.1 5.9 4685 FW*24-140 4 1.8 0.9 18.3 10.5 20.3 11.7 10.1 5.9 4685 FW*34-175 6 2.7 1.4 26.6 15.3 29.5 17.0 14.7 8.5 6774 FW*24-230 14.2 6.4 2.6 26.6 15.3 29.5 17.0 14.7 8.5 6774 FW*24-325 14.2 6.4 2.6 26.5 15.3 29.5 17.0 14.7 8.5 6774 FW*34-390 21.3 9.6 5.5 3.9 38.2 22.1 42.4 24.5 21.2 12.2 9747 FW*34-510 21.3 9.6 5.5 3.9 38.2 22.1 42.4 24.5 21.2 12.2 9747 FW*26-130 4 1.8 0.9 18.3 10.5 20.3 11.7 10.1 5.9 4685 FW*26-150 4 1.8 0.9 18.3 10.5 20.3 11.7 10.1 5.9 4685 FW*36-185 6 2.7 1.4 26.6 15.3 29.5 17.0 14.7 8.5 6774 FW*26-270 14.2 6.4 2.6 26.6 15.3 29.5 17.0 14.7 8.5 6774 FW*26-320 14.2 6.4 2.6 26.5 15.3 29.5 17.0 14.7 8.5 6774 FW*36-385 21.3 9.6 5.5 3.9 38.2 22.1 42.4 24.5 21.2 12.2 9747 FW*36-460 21.3 9.6 5.5 3.9 38.2 22.1 42.4 24.5 21.2 12.2 9747 FW*36-520 21.3 9.6 5.5 3.9 38.2 22.1 42.4 24.5 21.2 12.2 9747 * E = Electric defrost G=Hot gas defrost - Reverse cycle H= Hot gas Re-Evap 115V Available for Hot Gas Defrost units only. AIR DEFROST UNITS C O 4 O F L P E I R TOTAL MOTOR AMPS 60 HZ TOTAL MOTOR AMPS 60 HZ MODEL 115V 208/230V 460V MODEL 115V 208/230V 460V NUMBER 1PH 1PH 3PH 1PH NUMBER 1PH 1PH 3PH 1PH FWA24-126 4.0 1.8 0.9 FWA26-145 4.0 1.8 0.9 FWA24-169 4.0 1.8 0.9 C FWA26-191 4.0 1.8 0.9 FWA34-224 6.0 2.7 1.4 O 6 FWA36-240 6.0 2.7 1.4 FWA34-287 6.0 2.7 1.4 O F FWA36-305 6.0 2.7 1.4 FWA24-340 14.2 6.4 2.6 L P FWA26-370 14.2 6.4 2.6 FWA24-395 14.2 6.4 2.6 E I FWA36-415 21.3 9.6 5.5 3.9 R FWA34-465 21.3 9.6 5.5 3.9 FWA36-490 21.3 9.6 5.5 3.9 FWA34-585 21.3 9.6 5.5 3.9 FWA36-620 21.3 9.6 5.5 3.9 C O 8 O F L P E I R TOTAL MOTOR AMPS 60 HZ MODEL 115V 208/230V 460V NUMBER 1PH 1PH 3PH 1PH FWA28-151 4.0 1.8 0.9 FWA28-210 4.0 1.8 0.9 FWA38-260 6.0 2.7 1.4 FWA38-320 6.0 6.4 2.6 FWA28-410 14.2 6.4 2.6 FWA28-450 14.2 6.4 2.6 FWA38-540 21.3 9.6 5.5 3.9 FWA38-690 21.3 9.6 5.5 3.9 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 107

PHYSICAL DATA F R 4 E E F Z P E I R F R 6 E E F Z P E I R AIR DEFROST UNITS C O 4 O L F E P R I MODEL NUMBER MODEL NUMBER FAN DIA (in) FAN DIA (in) MOTOR DATA QTY HP RPM MOTOR DATA QTY HP RPM OPTIONAL HEAT EXCH (UNMTD) OPTIONAL HEAT EXCH (UNMTD) RE-EVAP HEAT EXCH (UNMTD) RE-EVAP HEAT EXCH (UNMTD) LIQUID ODS LIQUID ODS CONNECTIONS (in) SUCTION ODS CONNECTIONS (in) SUCTION H.G. ODS ODS DRAIN MPT FWA24-126 14 2 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 115 FWA24-169 14 2 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 130 FWA34-224 14 3 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 280 FWA34-287 14 3 1/8 1050 RXH250 N/A 1/2 1 1/8 N/A 3/4 310 FWA24-340 20 2 1/3 1075 RXH250 N/A 7/8 1 1/8 N/A 3/4 345 FWA24-395 20 2 1/3 1075 RXH250 N/A 7/8 1 1/8 N/A 3/4 375 FWA34-465 20 3 1/3 1075 RXH250 N/A 7/8 1 3/8 N/A 3/4 400 FWA34-585 20 3 1/3 1075 RXH350 N/A 7/8 1 3/8 N/A 3/4 505 H.G. ODS DRAIN MPT FW*24-105 14 2 1/8 1050 RXH150 HEA3A 1/2 1 1/8 7/8 3/4 120 FW*24-140 14 2 1/8 1050 RXH150 HEA3A 1/2 1 1/8 7/8 3/4 135 FW*34-175 14 3 1/8 1050 RXH150 HEA3A 1/2 1 1/8 7/8 3/4 285 FW*24-230 20 2 1/3 1075 RXH250 HEA4A 1/2 1 3/8 7/8 3/4 315 FW*24-325 20 2 1/3 1075 RXH350 HEA4A 7/8 1 3/8 7/8 3/4 350 FW*34-390 20 3 1/3 1075 RXH350 HEA4A 7/8 1 5/8 7/8 3/4 435 FW*34-510 20 3 1/3 1075 RXH500 HEA5A 7/8 1 5/8 7/8 3/4 530 FW*26-130 14 2 1/8 1050 RXH150 HEA3A 1/2 1 1/8 7/8 3/4 125 FW*26-150 14 2 1/8 1050 RXH150 HEA3A 1/2 1 1/8 7/8 3/4 140 FW*36-185 14 3 1/8 1050 RXH150 HEA3A 1/2 1 1/8 7/8 3/4 295 FW*26-270 20 2 1/3 1075 RXH250 HEA4A 1/2 1 3/8 7/8 3/4 320 FW*26-320 20 2 1/3 1075 RXH350 HEA4A 7/8 1 3/8 7/8 3/4 365 FW*36-385 20 3 1/3 1075 RXH350 HEA4A 7/8 1 5/8 7/8 3/4 450 FW*36-460 20 3 1/3 1075 RXH500 HEA5A 7/8 1 5/8 7/8 3/4 490 FW*36-520 20 3 1/3 1075 RXH500 HEA5A 7/8 1 5/8 7/8 3/4 535 SHIP WT (lbs.) SHIP WT (lbs.) C O 6 O L F E P R I C O 8 O L F E P R I FWA26-145 14 2 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 120 FWA26-191 14 2 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 140 FWA36-240 14 3 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 290 FWA36-305 14 3 1/8 1050 RXH250 N/A 1/2 1 1/8 N/A 3/4 320 FWA26-370 20 2 1/3 1075 RXH250 N/A 7/8 1 1/8 N/A 3/4 360 FWA36-415 20 3 1/3 1075 RXH250 N/A 7/8 1 1/8 N/A 3/4 395 FWA36-490 20 3 1/3 1075 RXH250 N/A 7/8 1 3/8 N/A 3/4 415 FWA36-620 20 3 1/3 1075 RXH350 N/A 7/8 1 3/8 N/A 3/4 520 FWA28-151 14 2 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 125 FWA28-210 14 2 1/8 1050 RXH150 N/A 1/2 7/8 N/A 3/4 145 FWA38-260 14 3 1/8 1050 RXH250 N/A 1/2 1 1/8 N/A 3/4 295 FWA38-320 14 3 1/8 1050 RXH250 N/A 1/2 1 1/8 N/A 3/4 330 FWA28-410 20 2 1/3 1075 RXH250 N/A 7/8 1 1/8 N/A 3/4 370 FWA28-450 20 2 1/3 1075 RXH250 N/A 7/8 1 3/8 N/A 3/4 390 FWA38-540 20 3 1/3 1075 RXH350 N/A 7/8 1 3/8 N/A 3/4 430 FWA38-690 20 3 3 1075 RXH350 N/A 7/8 1 3/8 N/A 3/4 540 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 108

DIMENSIONS ALL MODELS ELECTRIC AND HOT DIMENSIONS GAS DEFROST AIR DEFROST MODELS FIG. W A B FW*24-105 FW*26-130 FWA24-126 FWA26-145 FWA28-151 1 55 42 FW*24-140 FW*26-150 FWA24-169 FWA26-191 FWA28-210 1 55 42 FW*34-175 FW*36-185 FWA34-224 FWA36-240 FWA38-260 1 76 63 FWA34-287 FWA36-305 FWA38-320 1 76 63 FW*24-230 FW*26-270 FWA24-340 FWA26-370 FWA28-410 2 76 63 31-1/2 FW*24-325 FW*26-320 FWA24-395 FWA28-450 2 76 63 31-1/2 FW*36-385 FWA36-415 2 106 93 31 FW*34-390 FW*36-460 FWA34-455 FWA36-490 FWA38-540 2 106 93 31 FW*34-510 FW*36-520 FWA34-585 FWA36-620 FWA38-690 2 106 93 31 * E = Electric defrost H = Hot gas defrost - Re evap G = Hot gas defrost - Reverse cycle 3/4 MPT drain connections on all units Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 109

Large Profile Unit Cooler HW Series FEATURES AIR DEFROST - 16,400 to 273,000 BTUH ELECTRIC DEFROST - 11,800 to 248,000 BTUH HOT GAS DEFROST - 11,800 to 248,000 BTUH LARGE WALK-INS & WAREHOUSES COOLER & FREEZER APPLICATIONS APPLICATION - Large Profile unit coolers are ideally suited for a wide range of large coolers, freezers and blast freezers. The HW*U and HW*L models are designed for use below +25 F room temperature. The HW*M and HWAH models are designed for coolers in the medium and high temperature ranges. SIZES - There are 61 sizes available, ranging in capacity from 11,800 to 273,000 BTUH @ 10 TD, and ranging in air flow from 2,720 to 29,900 CFM. HOUSING - Rust-free, heavy gauge textured Aluminum; lightweight and durable. Air and electric defrost models have hinged drain pans to allow for convenient servicing and maintenance (Hot Gas drain pans are not hinged). LIFTING LEGS - 2 fan models and larger are shipped upright with removable lifting legs, allowing the unit to be installed quickly, and easily with a forklift. Slotted hangers are provided for fast installation. COIL - Seamless Copper tubes are mechanically expanded into heavy gauge corrugated Aluminum fins to assure maximum heat transfer. Die formed fin collars are provided for accurate fin spacing. Hangers are fastened directly to the tube sheets of the coil to provide high structural strength. All units are dehydrated, sealed and shipped with a nitrogen holding charge. REFRIGERANTS - For use with direct expansion, R-22, R-404A, and R-507. Specify refrigerant when ordering. A separate compartment is provided for all refrigeration connections, allowing ample room for internal mounting of expansion valve(s). Large Profile units can also be used for chilled water or glycol solutions, contact factory for selection. FANS - Powerful, heavy-duty Aluminum fans are individually balanced to provide vibration-free operation. Wire fan guards are epoxy coated for corrosion resistance. Optional air straighteners are available for increased air throw. MOTORS - All motors are high efficiency PSC, ball bearing type, life lubricated and thermally protected. HW*U and HW*L models use 3/4 1075 RPM or 3/4 HP, 1625 RPM motors. HW*M and HWAH models use 1/3 HP or 3/4 HP, 1075 RPM motors. ELECTRICAL - Available in 115/1, 208/230/1, 208/230/3, 460/1 and 460/3 (see page 10). Large Profile units can also be operated on 220/1/50, 220/3/50, 380/1/50, and 380/3/50 power (contact factory for details). All components are factory wired to convenient screw-type terminal blocks. A large compartment is supplied for all electrical components and is easily accessible by removing the end panel. AIR DEFROST - Available on HWAM and HWAH series only for use in coolers at +35 F and above. ELECTRIC DEFROST - Available on all but the HWAH models. Placement of the heaters within the refrigeration coil allow for a more efficient and rapid defrost cycle. This arrangement enables heat to be conducted from the center of the core out, for a more even defrost pattern. All heaters are factory wired to screw-type terminal blocks, allowing for a quick field change over from 1 to 3 phase or 230V to 460V and vice versa with the use of jumpers. An adjustable, remote bulb defrost termination and fan delay (DTFD) is mounted and wired. Drain pans are heated for fast, reliable drainage. Timer and contactors are available as options. Complete Electric Defrost systems are available from Carrier. HOT GAS RE-EVAP DEFROST - Available on all but the HWAH models. Includes an adjustable defrost termination and fan delay (DTFD), factory installed. A hot gas drain circuit is supplied, thus eliminating the need for electric heat and additional wiring. A Heat Exchanger/Re-Evaporator is supplied with every unit. Refer to the current Technical Bulletin HG for piping. Complete Hot Gas Re-Evap systems are available from Carrier, contact factory. HOT GAS REVERSE CYCLE DEFROST - Available on all but the HWAH models. Includes an adjustable defrost termination and fan delay. (DTFD) factory installed. A hot gas drain pan circuit is supplied, thus eliminating the need for electric heat and additional wiring. Refer to the current Technical Bulletin HG For piping. This unit is also used for Alternating Evaporator Systems. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 110

Large Profile Unit Cooler HW Series OPTIONS Copper fins. Inherent 3 phase motors. Coated fins (air and hot gas models only). Ultra low temperature motor grease for applications down to -60 F suction temperature. Galvanized steel casing. Insulated drain pans. High pressure propeller fans (up to 0.5 external pressure) Custom circuiting for chilled water or glycol applications. High air throw fan guards. AIR THROW Air throw is affected by installation variables. Optimum air throw is obtained by high ceiling with no interference from beams, product or return air restrictions. MODEL WIRE FAN GUARD FAN GUARD / AIR STRAIGHTENER HW*U / HW*L 60-80 feet 80-100 feet HW*M / HWAH 50-70 feet 70-90 feet Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 111

PERFORMANCE DATA F R 4 E E F Z P E I R F R 6 E E F Z P E I R CAPACITY BTUH @ 10 TD (404A, R-22) MODEL SUCTION TEMPERATURE NUMBER CFM -30 F -20 F -10 F +10 F HW*U1-118 3750 11800 12400 12900 14000 HW*U2-236 7500 23600 24700 25700 27900 HW*U2-355 8200 35500 37100 38700 42100 HW*U3-474 12450 47400 49500 51600 56100 HW*U4-711 16400 71100 72800 74500 81000 HW*U4-851 21600 85100 89000 92800 100900 HW*U4-1080 21600 108000 112900 117700 128000 HW*U5-1350 26200 135000 141000 147000 160000 HW*U6-1620 32400 162000 176600 176600 192000 HW*L1-125 3750 10900 11700 12500 13500 HW*L1-152 3650 13200 14200 15200 16400 HW*L1-193 3550 16800 18100 19300 20800 HW*L2-240 7600 20900 22400 24000 25900 HW*L2-304 7300 26400 28400 30400 32800 HW*L2-361 8300 31400 33800 36100 39000 HW*L2-408 8100 35500 38200 40800 44100 HW*L3-445 12800 38700 41600 44500 48000 HW*L3-540 12450 47000 50500 54000 58300 HW*L3-613 12150 53300 57300 61300 66200 HW*L3-660 11800 57400 61700 66000 71200 HW*L4-722 16600 62700 67500 72200 78000 HW*L4-817 16200 71100 76400 81700 88200 HW*L4-950 21500 82500 88900 95000 102600 HW*L4-1100 21200 95700 102900 110000 118800 HW*L4-1260 20800 109600 117800 126000 136000 HW*L4-1380 20400 120000 129000 138000 149000 HW*L5-1575 26000 137000 147300 157500 170000 HW*L5-1725 25500 150000 161300 172500 186300 HW*L6-1890 31200 164400 176700 189000 204000 HW*L6-2070 32100 180000 193500 207000 223500 C O 6 O L F E P R I MODEL NUMBER CFM CAPACITY BTUH@10 TD +20 F MODEL NUMBER CFM CAPACITY BTUH@10 TD +20 F HW*M1-164 2920 16400 HWAH1-182 2800 18200 HW*M1-209 2840 20900 HWAH1-232 2720 23200 HW*M2-270 7000 27000 HWAH2-300 6880 30000 HW*M2-329 6840 32900 HWAH2-365 6600 36500 C HW*M2-390 6640 39000 HWAH2-433 6400 43300 O 8 HW*M2-441 6480 44100 O HWAH2-490 6250 49000 HW*M3-583 9960 58300 L F HWAH3-530 9800 53000 HW*M3-662 9720 66200 E P HWAH3-648 9600 64800 HW*M4-780 13280 78000 R I HWAH3-736 9400 73600 HW*M4-882 12960 88200 HWAH4-866 12800 86600 HW*M4-1100 21700 110000 HWAH4-980 12500 98000 HW*M4-1320 21200 132000 HWAH4-1100 12200 110000 HW*M4-1656 20400 165600 HWAH4-1452 20700 145200 HW*M5-2065 25500 206500 HWAH4-1821 19900 182100 HW*M6-2480 30600 248000 HWAH5-2275 24900 227500 HWAH6-2730 29900 273000 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 112

F R 4 E E F Z P E I R F R 6 E E F Z P E I R C O 6 O L F E P R I C O 8 O L F E P R I MODEL NUMBER FAN DIA (In.) MOTOR DATA (1) RE-EVAP CONNECTIONS (In.) 2 OPTIONAL HEAT HEAT EXCH. SUCT. H.G. QTY HP RPM EXCH. LIQUID (UNMTD.) ODS ODS (UNMTD.) DRAIN MPT Ship Wt.(Lbs.) HW*U1-118 20 1 3/4 1625 RHX-150 HEA2A 1/2FL 1-1/8 7/8 3/4 190 HW*U2-236 20 2 3/4 1625 RHX-250 HEA3A 7/8 ODS 1-3/8 7/8 3/4 370 HW*U2-355 24 2 3/4 1075 RHX-350 HEA4A 7/8 ODS 1-5/8 7/8 3/4 440 HW*U3-474 24 3 3/4 1075 RHX-350 HEA5A 7/8 ODS 1-5/8 7/8 3/4 570 HW*U4-711 24 4 3/4 1075 RHX-500 HEA6A 7/8 ODS 2-1/8 1-1/8 1-1/4 665 HW*U4-851 24 4 3/4 1075 (2) RHX-500 (2) HEA5A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 875 HW*U4-1080 24 4 3/4 1075 (2) RHX-500 (2) HEA5A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 900 HW*U5-1350 24 5 3/4 1075 (2) RHX-500 N/A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 1125 HW*U6-1620 24 6 3/4 1075 (2) RHX-500 N/A (2) 1-1/8 ODS (2) 2-5/8 1-1/8 1-1/4 1350 HW*L1-125 20 1 3/4 1625 RHX-150 HEA3A 1/2FL 1-1/8 7/8 3/4 180 HW*L1-152 20 1 3/4 1625 RHX-150 HEA3A 1/2FL 1-1/8 7/8 3/4 200 HW*L1-193 20 1 3/4 1625 RHX-150 HEA3A 5/8 ODS 1-1/8 7/8 3/4 220 HW*L2-240 20 2 3/4 1625 RHX-250 HEA4A 7/8 ODS 1-3/8 7/8 3/4 370 HW*L2-304 20 2 3/4 1625 RHX-250 HEA4A 7/8 ODS 1-3/8 7/8 3/4 400 HW*L2-361 24 2 3/4 1075 RHX-350 HEA4A 7/8 ODS 1-5/8 7/8 3/4 425 HW*L2-408 24 2 3/4 1075 RHX-350 HEA5A 7/8 ODS 1-5/8 7/8 3/4 446 HW*L3-445 24 3 3/4 1075 RHX-500 HEA5A 7/8 ODS 2-1/8 7/8 3/4 525 HW*L3-540 24 3 3/4 1075 RHX-500 HEA5A 7/8 ODS 2-1/8 7/8 3/4 585 HW*L3-613 24 3 3/4 1075 RHX-500 HEA6A 7/8 ODS 2-1/8 7/8 3/4 620 HW*L3-660 24 3 3/4 1075 RHX-500 HEA6A 7/8 ODS 2-1/8 7/8 3/4 645 HW*L4-722 24 4 3/4 1075 RHX-500 HEA6A 1-3/8 ODS 2-1/8 1-1/8 1-1/4 675 HW*L4-817 24 4 3/4 1075 RHX-500 (2) HEA5A 7/8 ODS 2-1/8 1-1/8 1-1/4 726 HW*L4-950 24 4 3/4 1075 RHX-500 (2) HEA5A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 850 HW*L4-1100 24 4 3/4 1075 (2) RHX-500 (2) HEA5A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 885 HW*L4-1260 24 4 3/4 1075 (2) RHX-500 (2) HEA6A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 895 HW*L4-1380 24 4 3/4 1075 (2) RHX-500 (2) HEA6A (2) 7/8 ODS (2) 2-1/8 1-1/8 1-1/4 910 HW*L5-1575 24 5 3/4 1075 (2) RHX-500 N/A (2) 1-1/8 ODS (2) 2-1/8 1-1/8 1-1/4 1120 HW*L5-1725 24 5 3/4 1075 (2) RHX-500 N/A (2) 1-1/8 ODS (2) 2-1/8 1-1/8 1-1/4 1140 HW*L6-1890 24 6 3/4 1075 (2) RHX-500 N/A (2) 1-3/8 ODS (2) 2-5/8 1-1/8 1-1/4 1345 HW*L6-2070 24 6 3/4 1075 (2) RHX-500 N/A (2) 1-3/8 ODS (2) 2-5/8 1-1/8 1-1/4 1365 HW*M1-164 20 1 1/3 1075 RHX-150 HEA3A 1/2FL 7/8 7/8 3/4 200 HW*M1-209 20 1 1/3 1075 RHX-150 HEA3A 5/8 ODS 7/8 7/8 3/4 220 HW*M2-270 20 2 1/3 1075 RHX-250 HEA4A 5/8 ODS 1-1/8 7/8 3/4 360 HW*M2-329 20 2 1/3 1075 RHX-250 HEA4A 5/8 ODS 1-1/8 7/8 3/4 400 HW*M2-390 24 2 1/3 1075 RHX-250 HEA4A 5/8 ODS 1-1/8 7/8 3/4 425 HW*M2-441 24 2 1/3 1075 RHX-250 HEA5A 5/8 ODS 1-1/8 7/8 3/4 446 HW*M3-583 24 3 1/3 1075 RHX-350 HEA5A 5/8 ODS 1-3/8 7/8 3/4 585 HW*M3-662 24 3 1/3 1075 RHX-350 HEA6A 7/8 ODS 1-3/8 7/8 3/4 620 HW*M4-780 24 4 1/3 1075 RHX-350 HEA6A 7/8 ODS 1-3/8 1-1/8 1-1/4 675 HW*M4-882 24 4 1/3 1075 RHX-500 (2) HEA5A 7/8 ODS 1-3/8 1-1/8 1-1/4 726 HW*M4-1100 24 4 3/4 1075 (2) RHX-350 (2) HEA5A 7/8 ODS 1-5/8 1-1/8 1-1/4 830 HW*M4-1320 24 4 3/4 1075 (2) RHX-350 (2) HEA5A 1-1/8 ODS 1-5/8 1-1/8 1-1/4 885 HW*M4-1656 24 4 3/4 1075 (2) RHX-500 (2) HEA6A 1-1/8 ODS 2-1/8 1-1/8 1-1/4 910 HW*M5-2065 24 5 3/4 1075 (2) RHX-500 N/A 1-5/8 ODS 2-5/8 1-1/8 1-1/4 1140 HW*M6-2480 24 6 4 1075 500 A 1-8 ODS 2-5 8 1-1 8 1-1 4 1365 HWAH1-182 20 1 1/3 1075 RHX-150 N/A 5/8 ODS 7/8 N/A 3/4 210 HWAH1-232 20 1 1/3 1075 RHX-150 N/A 5/8 ODS 7/8 N/A 3/4 230 HWAH2-300 20 2 1/3 1075 RHX-250 N/A 5/8 ODS 1-1/8 N/A 3/4 370 HWAH2-365 20 2 1/3 1075 RHX-250 N/A 5/8 ODS 1-1/8 N/A 3/4 410 HWAH2-433 24 2 1/3 1075 RHX-250 N/A 5/8 ODS 1-1/8 N/A 3/4 435 HWAH2-490 24 2 1/3 1075 RHX-250 N/A 5/8 ODS 1-1/8 N/A 3/4 458 HWAH3-530 24 3 1/3 1075 RHX-250 N/A 7/8 ODS 1-3/8 N/A 3/4 550 HWAH3-648 24 3 1/3 1075 RHX-350 N/A 7/8 ODS 1-3/8 N/A 3/4 600 HWAH3-736 24 3 1/3 1075 RHX-350 N/A 7/8 ODS 1-3/8 N/A 3/4 635 HWAH4-866 24 4 1/3 1075 RHX-350 N/A 7/8 ODS 1-3/8 N/A 1-1/4 690 HWAH4-980 24 4 1/3 1075 RHX-500 N/A 7/8 ODS 1-3/8 N/A 1-1/4 746 HWAH4-1100 24 4 1/3 1075 (2) RHX-350 N/A 7/8 ODS 1-3/8 N/A 1-1/4 785 HWAH4-1452 24 4 3/4 1075 (2) RHX-350 N/A 7/8 ODS 1-5/8 N/A 1-1/4 905 HWAH4-1821 24 4 3/4 1075 (2) RHX-500 N/A 7/8 ODS 2-1/8 N/A 1-1/4 930 HWAH5-2275 24 5 3/4 1075 (2) RHX-500 N/A 1-7/8 ODS 2-5/8 N/A 1-1/4 1165 HWAH6-2730 24 6 3/4 1075 (2) RHX-500 N/A (2) 1-3/8 ODS (2) 2-5/8 N/A 1-1/4 1395 (1) All motors are single phase. All three fan models and larger are delta wired for three phase power. Inherent three phase motors are available, contact factory. (2) All Large Profile units are custom circuited for optimum performance and operating efficiency. Should conditions vary from those listed to the right, *connection sizes and quantity may be subject to change, contact factory to confirm. * Connection sizes are based on the following criteria: HW*U: - 30 ST, 10 TD R-404A HW*L: - 20 ST, 10 TD R-404A HW*M: +20 ST, 10 TD R-22 HWAH: +25 ST, 10 TD R-22 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 113

DIMENSIONS AIR & ELECTRIC DEFROST MODELS HW*L1-125 HW*L1-152 HW*L1-193 HW*L2-240 HW*L2-304 HW*L2-361 HW*L2-408 HW*L3-445 HW*L3-540 HW*L3-540-612 HW*L3-660 HW*L4-722 HW*L4-817 HW*L4-950 HW*L4-1100 HW*L4-1260 HW*L4-1380 HW*L5-1575 HW*L5-1725 HW*L6-1890 HW*L6-2070 AIR AND ELECTRIC DEFROST MODELS HW*U1-118 HW*U2-236 HW*U2-355 HW*U3-474 HW*U4-711 HW*U4-851 HW*U4-1080 HW*M1-164 HW*M1-209 HW*M2-270 HW*M2-329 HW*M2-390 HW*M2-441 HW*M3-583 HW*M3-662 HW*M4-780 HW*M4-882 HW*M4-1100 HW*M4-1320 HW*M4-1656 HWAH1-182 HWAH1-232 QTY OF HANGERS FIG. DIMENSIONS (IN.) A B C D E 2 1 22-3/4 25-3/4 46-1/8 46-1/2 4 HWAH2-300 HWAH2-365 3 1 22-3/4 26 76-1/8 76-1/2 4 HWAH2-433 HWAH2-490 3 1 24-1/2 31-3/4 76-1/8 76-1/2 5-3/4 HWAH3-530 HWAH3-648 HWAH3-796 4 1 24-1/2 32 106-1/8 106-1/2 5-3/4 HWAH4-866 HWAH4-980 HWAH4-1100 5 1 24-1/2 32-1/4 136-1/8 136-1/2 5-3/4 HWAH4-1452 HWAH4-1621 5 2 24-1/2 50-1/4 136-1/8 136-1/2 5-3/4 HW*U5-1350 HW*M5-2065 HWAH5-2275 6 2 24-1/2 50-1/2 166-1/8 166-1/2 5-3/4 HW*U6-1620 HW*M6-2480 HWAH6-2730 7 2 24-1/2 50-3/4 196-1/8 196-1/2 5-3/4 FIGURE 1 FIGURE 2 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 114

DIMENSIONS HOT GAS DEFROST MODELS AIR AND ELECTRIC DEFROST MODELS HW*L1-125 HW*L1-152 HW*L1-193 HW*L2-240 HW*L2-304 HW*L2-361 HW*L2-408 HW*L3-445 HW*L3-540 HW*L3-613 HW*L3-660 HW*L4-722 HW*L4-817 HW*L4-950 HW*L4-1100 HW*L4-1260 HW*L4-1380 HW*L5-1575 HW*L5-1725 HW*L6-1890 HW*L6-2070 HW*U1-118 HW*U2-236 HW*U2-355 HW*U3-474 HW*U4-711 HW*U4-851 HW*U4-1080 HW*M1-164 HW*M1-209 HW*M2-270 HW*M2-329 HW*M2-390 HW*M2-441 HW*M3-583 HW*M3-662 HW*M4-780 HW*M4-882 HW*M4-1100 HW*M4-1320 HW*M4-1656 QTY OF HANGERS FIG. DIMENSIONS (IN.) A B C D E F 2 3 22-3/4 26-7/8 46-1/8 46-1/2 4 26-1/8 3 3 22-3/4 27-3/8 76-1/8 76-1/2 4 26-1/8 3 3 24-1/2 33-3/8 76-1/8 76-1/2 5-3/4 32-1/8 4 3 24-1/2 33-7/8 106-1/8 106-1/2 5-3/4 32-1/8 5 3 24-1/2 34-1/4 136-1/8 136-1/2 5-3/4 32-1/8 5 4 24-1/2 52-1/4 136-1/8 136-1/2 5-3/4 50-1/8 HW*U5-1350 HW*M5-2065 6 4 24-1/2 52-3/4 166-1/8 166-1/2 5-3/4 50-1/8 HW*U6-1620 HW*M6-2480 7 4 24-1/2 53-1/4 196-1/8 196-1/2 5-3/4 50-1/8 FIGURE 3 FIGURE 4 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 115

ELECTRICAL DATA F R 4 E E F Z P E I R F R 6 E E F Z P E I R TOTAL MOTOR AMPS (3) ELECTRIC DEFROST (4) MODEL 60 Hz AMPERAGE RATINGS @ 60 Hz WATTS NUMBER 115 V. 208/230 V. 460 V. 208 V. 230 V. 460 V. 1 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH 1 PH 3 PH HW*U1-118 ----- 4.2 ----- 2.1 ----- 19.9 13.2 22.0 14.6 11.0 9.5 5,512 HW*U2-236 ----- 8.4 ----- 4.2 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*U2-355 ----- 8.4 ----- 4.2 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*U3-474 ----- 12.6 7.3 ----- 3.6 ----- 33.8 ----- 37.4 28.5 24.5 14,152 HW*U4-711 ----- 16.8 11.1 ----- 5.6 ----- 43.3 ----- 47.8 ----- 26.0 18,440 HW*U4-851 ----- 16.8 11.1 ----- 5.6 ----- 61.0 ----- 67.5 ----- 33.8 27,660 HW*U4-1080 ----- 16.8 11.1 ----- 5.6 ----- 61.0 ----- 67.5 ----- 33.8 27,660 HW*U5-1350 ----- 21.0 14.6 ----- 7.3 ----- 75.2 ----- 83.9 ----- 41.6 34,575 HW*U6-1620 ----- 25.2 14.6 ----- 7.3 ----- 89.3 ----- 98.7 ----- 49.3 41,490 HW*L1-125 ----- 4.2 ----- 2.1 ----- 19.9 13.2 22.0 14.6 11.0 9.5 5,512 HW*L1-152 ----- 4.2 ----- 2.1 ----- 19.9 13.2 22.0 14.6 11.0 9.5 5,512 HW*L1-193 ----- 4.2 ----- 2.1 ----- 19.9 13.2 22.0 14.6 11.0 9.5 5,512 HW*L2-240 ----- 8.4 ----- 4.2 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*L2-304 ----- 8.4 ----- 4.2 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*L2-361 ----- 8.4 ----- 4.2 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*L2-408 ----- 8.4 ----- 4.2 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*L3-445 ----- 12.6 7.3 ----- 3.6 ----- 33.8 ----- 37.4 28.2 24.5 14,152 HW*L3-540 ----- 12.6 7.3 ----- 3.6 ----- 33.8 ----- 37.4 28.2 24.5 14,152 HW*L3-613 ----- 12.6 7.3 ----- 3.6 ----- 33.8 ----- 37.4 28.2 24.5 14,152 HW*L3-660 ----- 12.6 7.3 ----- 3.6 ----- 33.8 ----- 37.4 28.2 24.5 14,152 HW*L4-722 ----- 16.8 11.1 ----- 5.6 ----- 43.2 ----- 47.8 ----- 26.0 18,440 HW*L4-817 ----- 16.8 11.1 ----- 5.6 ----- 43.2 ----- 47.8 ----- 26.0 18,440 HW*L4-950 ----- 16.8 11.1 ----- 5.6 ----- 61.0 ----- 67.5 ----- 33.8 27,660 HW*L4-1100 ----- 16.8 11.1 ----- 5.6 ----- 61.0 ----- 67.5 ----- 33.8 27,660 HW*L4-1260 ----- 16.8 11.1 ----- 5.6 ----- 61.0 ----- 67.5 ----- 33.8 27,660 HW*L4-1380 ----- 16.8 11.1 ----- 5.6 ----- 61.0 ----- 67.5 ----- 33.8 27,660 HW*L5-1575 ----- 21.0 14.6 ----- 7.3 ----- 75.2 ----- 83.9 ----- 41.6 34,575 HW*L5-1725 ----- 21.0 14.6 ----- 7.3 ----- 75.2 ----- 83.9 ----- 41.6 34,575 HW*L6-1890 ----- 25.2 14.6 ----- 7.3 ----- 89.3 ----- 98.1 ----- 49.3 41,490 HW*L6-2070 ----- 25.2 14.6 ----- 7.3 ----- 89.3 ----- 98.1 ----- 49.3 41,490 C O 6 O L F E P R I HW*M1-164 7.1 3.2 ----- 1.3 ----- 19.9 13.2 22.0 14.6 11.0 9.5 5,512 HW*M1-209 7.1 3.2 ----- 1.3 ----- 19.9 13.2 22.0 14.6 11.0 9.5 5,512 HW*M2-270 14.2 6.4 ----- 2.6 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*M2-329 14.2 6.4 ----- 2.6 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*M2-390 14.2 6.4 ----- 2.6 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*M2-441 14.2 6.4 ----- 2.6 ----- 35.5 23.5 39.3 26.0 19.6 17.0 9,832 HW*M3-583 21.3 9.6 5.5 3.9 2.9 ----- 33.8 ----- 37.4 ----- 24.5 14,152 HW*M3-662 21.3 9.6 5.5 3.9 2.9 ----- 33.8 ----- 37.4 ----- 24.5 14,152 HW*M4-780 28.4 12.8 8.5 5.2 4.5 ----- 43.3 ----- 47.8 ----- 24.3 18,440 HW*M4-882 28.4 12.8 8.5 5.2 4.5 ----- 43.3 ----- 47.8 ----- 24.3 18,440 HW*M4-1100 ----- 16.8 11.1 8.4 5.6 ----- 64.3 ----- 71.3 ----- 33.7 27,660 HW*M4-1320 ----- 16.8 11.1 8.4 5.6 ----- 64.3 ----- 71.3 ----- 33.7 27,660 HW*M4-1656 ----- 16.8 11.1 8.4 5.6 ----- 64.3 ----- 71.3 ----- 33.7 27,660 HW*M5-2065 ----- 21.0 14.6 11.5 7.3 ----- 72.2 ----- 79.8 ----- 39.9 34,575 HW*M6-2480 ----- 25.2 14.6 12.6 7.3 ----- 86.6 ----- 95.7 ----- 47.9 41,490 C O 8 O L F E P R I MODEL NUMBER TOTAL MOTOR AMPS (3) 60 Hz TOTAL MOTOR AMPS (3) 60 Hz MODEL 115 V. 208/230 V. 460 V. NUMBER 115 V. 208/230 V. 460 V. 1 PH 1 PH 3 PH 1 PH 3 PH 1 PH 1 PH 3 PH 1 PH 3 PH HWAH1-182 7.1 3.2 ----- 1.3 ----- HWAH3-736 21.3 9.6 5.5 3.9 2.9 HWAH1-232 7.1 3.2 ----- 1.3 ----- HWAH4-866 28.4 12.8 8.5 5.2 4.5 HWAH2-300 14.2 6.4 ----- 2.6 ----- HWAH4-980 28.4 12.8 8.5 5.2 4.5 HWAH2-365 14.2 6.4 ----- 2.6 ----- HWAH4-1100 28.4 12.8 8.5 5.2 4.5 HWAH2-433 14.2 6.4 ----- 2.6 ----- HWAH4-1452 ----- 16.8 11.1 8.4 5.6 HWAH2-490 14.2 6.4 ----- 2.6 ----- HWAH4-1821 ----- 16.8 11.1 8.4 5.6 HWAH3-530 21.3 9.6 5.5 3.9 2.9 HWAH5-2275 ----- 21.0 14.6 11.5 7.3 HWAH3-648 21.3 9.6 5.5 3.9 2.9 HWAH6-2730 ----- 25.2 14.6 12.6 7.3 HWAH models are only available in air defrost and are not recommended for applications below 35 F room temperature. (3) All models have single phase motors. Three fan models and larger are delta wired for three phase supply power. (4) All electric defrost models are standard three phase heaters unless otherwise specified. See table above to determine models applicable to single phase heater applications. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 116

Air Cooled Condensing Units 1/2 to 6 HP CS Seriesss AIR COOLED CONDENSING UNITS 1/2 TO 6 HP CS SERIES MEDIUM TO LOW TEMPERATURE UNITS - TECUMSEH HERMETIC/CARLYE SEMI-HERMETIC COMPRESSORS 117

FEATURES AND OPTIONS DESCRIPTION STANDARD UNITS PACKAGED UNITS CSEU CSEC CSLU CSLC Hermetic STD N/A STD N/A Semi-Hermetic N/A STD N/A STD Oil Failure Control (as required) N/R STD N/R STD ELECTRICAL Encapsulated high and low pressure controls** STANDARD STANDARD CONTROLS Compressor contactor (1Ø or 3Ø), start kit (1Ø) STANDARD STANDARD Control transformer {460v to 230v) as required STANDARD STANDARD CONDENSER Copper tubes, Aluminum fins STANDARD STANDARD Fan Motor(s) - overload protection STANDARD STANDARD Fan Blade(s) individually balanced STANDARD STANDARD Fan Guard(s) OPTIONAL OPTIONAL Suction line (vibrasorber± and piping only) OPTIONAL STANDARD Suction kit (vibrasorber, piping and suction filter) OPTIONAL OPTIONAL Suction line accumulator OPTIONAL OPTIONAL PIPING *Liquid line kit OPTIONAL STANDARD COMPONENTS Discharge vibrasober N/R STD N/R STD Replaceable core filters CONTACT FACTORY CONTACT FACTORY Hot gas bypass controls CONTACT FACTORY CONTACT FACTORY Oil separator and suction accumulator (both) CONTACT FACTORY CONTACT FACTORY RECEIVER Shut-off valve(s) STANDARD STANDARD Fusible plug STANDARD STANDARD HOUSING Galvanized steel all weather housing STANDARD STANDARD Control Panel STANDARD STANDARD LOW AMBIENT Fan cycle control (2 Fan models only) OPTIONAL OPTIONAL CONTROLS Flooded head pressure control OPTIONAL STANDARD Air defrost time clock OPTIONAL STANDARD DEFROST Electric defrost package OPTIONAL (1) (1) PROVISIONS Hot Gas Defrost CONTACT FACTORY CONTACT FACTORY UL and C-UL listed STANDARD STANDARD TESTING Leak and dielectric tested before shipping STANDARD STANDARD Dry Nitrogen shipping charge (25 to 35 PSI) STANDARD STANDARD STD = Standard Feature N/R = Not Required N/A = Not Applicable OPT = Optional Feature ± Vibrasorber not required for Hermetic compressors. Add optional kit SPR-VB if suction vibrasorber required. Standard for 2-1/2 through 6HP Models. For ½ to 2HP models, add kit number SPR-VB to include vibrasorbers and compressor spring mounting. * Liquid line kit includes: piping, filter drier, sight glass/moisture indicator. * * Adjustable low pressure control on low temp models in lieu of fixed control. (1) Electric defrost kit is included on low temperature models. ED-10-230/1 for 1/2-3HP models, and ED11-230/3 for 4-6 HP models. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 118

PERFORMANCE DATA HERMETIC MODELS PHYSICAL DATA CAPACITY (BTUH) AT 95 F AMBIENT 4 0 4 A 2 2 MODEL NUMBER NOM HP SUCTION TEMPERATURE F REC R Fig @90% (Lbs) LIQ. CONN. (ODS, IN.) +40 +30 +25 +20 +10 0-10 -20-25 -30-40 CS*U050M44 0.50 ----- 5660 5110 4550 3470 ----- ----- ----- ----- ----- ----- 5.1 1 3/8 5/8 152 CS*U075M44 0.75 ----- 8150 7450 6790 5550 4290 ----- ----- ----- ----- ----- 5.1 1 3/8 5/8 167 CS*U101M44 1.00 ----- 12150 11240 10310 8430 6610 4980 ----- ----- ----- ----- 8.6 2 3/8 5/8 195 CS*U150M44 1.50 ----- 15290 14060 12830 10410 8030 5680 ----- ----- ----- ----- 8.6 2 3/8 7/8 228 CS*U201M44 2.00 ----- 22570 20910 19350 16330 13520 10340 ----- ----- ----- ----- 8.6 2 3/8 7/8 253 CS*U300M44 3.00 ----- 25790 24190 22260 18090 13490 ----- ----- ----- ----- ----- 13.7 2 1/2 1-1/8 273 CS*U400M44 4.00 ----- 35460 32630 29900 24650 19300 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 390 CS*U500M44 5.00 ----- 40040 36520 33330 27170 21120 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 405 CS*U050L44 0.50 ----- ----- ----- ----- ----- 2760 2100 1590 1250 ----- ----- 5.1 1 3/8 5/8 152 CS*U075L44 0.75 ----- ----- ----- ----- ----- 4280 3450 2710 2380 2070 1570 5.1 1 3/8 5/8 157 CS*U100L44 1.00 ----- ----- ----- ----- ----- 5670 4580 3580 3130 2700 1940 5.1 1 3/8 5/8 180 CS*U150L44 1.50 ----- ----- ----- ----- ----- 9870 7670 5680 4760 3900 2330 8.6 2 3/8 7/8 195 CS*U200L44 2.00 ----- ----- ----- ----- ----- 14260 11240 8620 7390 6210 4020 8.6 2 3/8 7/8 243 CS*U300L44 3.00 ----- ----- ----- ----- ----- 17230 13960 10640 9070 7570 4790 13.7 2 1/2 1-1/8 255 CS*U050H22 0.50 7560 6330 5650 4980 3890 2850 ----- ----- ----- ----- ----- 6.0 1 3/8 5/8 170 CS*U075H22 0.75 9280 7690 6930 5990 5030 4010 ----- ----- ----- ----- ----- 6.0 1 3/8 5/8 175 CS*U125H22 1.00 13820 11370 10290 9150 7190 5380 ----- ----- ----- ----- ----- 6.0 1 3/8 5/8 180 CS*U150H22 1.50 17410 14220 12670 11230 8600 6290 ----- ----- ----- ----- ----- 10.0 2 3/8 7/8 210 CS*U200H22 2.00 22050 17980 16160 14340 11030 7940 ----- ----- ----- ----- ----- 10.0 2 3/8 7/8 223 CS*U250H22 2.50 28820 23320 20790 18370 13970 10500 ----- ----- ----- ----- ----- 16.0 2 1/2 7/8 245 CS*U300H22 3.00 35530 29150 26180 23430 18150 13200 ----- ----- ----- ----- ----- 16.0 2 1/2 7/8 260 CS*U400H22 4.00 45540 36850 32670 28820 21890 15950 ----- ----- ----- ----- ----- 28.2 3 1/2 7/8 348 CS*U500H22 5.00 57010 46770 41970 37500 29330 22350 ----- ----- ----- ----- ----- 28.2 3 1/2 7/8 380 SUC APP. SHIP WT. (LBS) NOTE: For 90 F ambient multiply capacity by 1.03. Reduce capacity by 3% for each increase in ambient temperature. Consult factories for capacities above. ELECTRICAL DATA HERMETIC MODELS MODEL COMP. AMPS @ 230/1/60 AMPS @ 208/230/3/60 AMPS @460/3/60 NUMBER MODEL COMPRESSOR COND TOTAL MCA COMPRESSOR COND TOTAL MCA COMPRESSOR COND TOTAL MCA NUMBER RLA LRA FLA UNIT RLA LRA FLA UNIT RLA LRA FLA UNIT CS*U050M44 AKA9438Z 4.3 31.0 1.0 6.3 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U075M44 AKA9462Z 6.8 34.0 1.0 8.8 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U101M44 AJA7494Z 8.9 54.0 2.0 14.0 17.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U150M44 AWA9512Z 8.9 60.0 2.0 13.9 17.0 5.5 50.0 2.0 10.5 15.0 ----- ----- ----- ----- ----- CS*U200M44 AVA9519Z 14.5 95.0 2.0 19.0 23.0 9.4 73.4 2.0 13.4 16.0 ----- ----- ----- ----- ----- CS*U300M44 AVA9522Z 17.0 108.0 2.0 21.0 26.0 10.3 74.0 2.0 14.4 19.0 ----- ----- ----- ----- ----- CS*U400M44 AVA9528Z 20.0 132.0 3.2 28.1 35.0 13.3 110.0 3.2 19.5 24.0 6.6 55.0 2.1 9.7 15.0 CS*U500M44 AGA9530Z 25.0 165.0 3.2 34.9 43.0 16.0 126.0 3.2 24.9 31.0 7.5 62.0 2.1 11.2 15.0 CS*U050L44 AKA9438Z 4.3 31.0 1.0 7.4 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U075L44 AJB2433Z 4.7 37.0 1.0 6.7 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U100L44 AJB2444Z 6.5 55.0 1.0 8.5 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U150L44 AWA2460Z 8.2 86.0 2.0 14.4 18.0 5.6 63.4 2.0 10.0 15.0 ----- ----- ----- ----- ----- CS*U200L44 AVA2490Z 11.4 106.6 2.0 19.7 24.0 7.4 65.1 2.0 13.2 16.0 ----- ----- ----- ----- ----- CS*U300L44 AVA2512Z 16.9 120.3 2.0 23.5 28.0 9.3 65.1 2.0 15.3 18.0 4.6 38.3 1.0 8.1 15.0 CS*U050H22 AKA9442E 4.0 31.0 1.0 7.9 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U075H22 AKA9455E 4.9 31.0 1.0 9.1 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U125H22 AJA9484E 6.9 54.0 1.0 9.0 15.0 ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- CS*U150H22 AWG5520E 9.3 52.0 2.0 12.0 15.0 5.8 51.0 2.0 9.0 15.0 ----- ----- ----- ----- ----- CS*U200H22 AWG5524E 11.0 60.0 2.0 16.5 20.0 6.7 50.0 2.0 10.5 15.0 ----- ----- ----- ----- ----- CS*U250H22 AVA5532E 14.5 78.0 2.0 19.0 23.0 8.9 59.5 2.0 13.6 17.0 4.4 32.8 1.0 6.2 15.0 CS*U300H22 AVA5542E 19.7 108.0 2.0 22.4 28.0 12.0 74.0 2.0 16.1 20.0 6.0 37.0 1.0 7.4 15.0 CS*U400H22 AVD5548E 19.2 110.0 3.2 23.4 29.0 12.3 105.0 3.2 16.5 20.0 6.2 52.2 2.1 8.8 15.0 CS*U500H22 AVB5558E 24.8 141.0 3.2 33.2 41.0 15.7 110.0 3.2 22.2 27.0 7.8 55.0 2.1 11.7 15.0 Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 119

PERFORMANCE DATA SEMI-HERMETIC MODELS PHYSICAL DATA 4 0 4 A 2 2 CAPACITY (BTUH) AT 95 F AMBIENT REC R CONN Approx MODEL NOM SUCTION TEMPERATURE F @ 90% Fig (ODS. IN.) ShipWt. NUMBER HP +40 +35 +25 +20 +10 0-10 -20-25 -35-40 (Lbs.) Liq. Suc. (lbs.) CS*C300M44 3.0 ----- ----- 26420 23960 19330 15130 ----- ----- ----- ----- ----- 13.7 2 1/2 7/8 330 CS*C400M44 5.0 ----- ----- 42130 37390 29990 22750 ----- ----- ----- ----- ----- 24.3 3 1/2 7/8 455 CS*C500M44 5.0 ----- ----- 55620 50040 39720 30560 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 475 CS*C600M44 6.5 ----- ----- 63150 57000 45580 35340 ----- ----- ----- ----- ----- 24.3 3 1/2 1-1/8 490 CS*C200L44 2.0 ----- ----- ----- ----- ----- 17320 13840 10770 9400 6990 5930 13.7 2 1/2 7/8 340 CS*C300L44 3.0 ----- ----- ----- ----- ----- 25750 19630 14440 12180 8320 6690 24.3 3 1/2 1-1/8 470 CS*C400L44 4.0 ----- ----- ----- ----- ----- 33470 26470 20290 17510 12560 10380 24.3 3 1/2 1-1/8 475 CS*C500L44 5.0 ----- ----- ----- ----- ----- 38890 31300 24520 21430 15850 13350 24.3 3 1/2 1-3/8 490 CS*C600L44 6.5 ----- ----- ----- ----- ----- 45520 36120 27840 24120 17500 14590 24.3 3 1/2 1-3/8 500 CS*C300M22 3.0 ----- ----- 25350 22740 17980 13810 ----- ----- ----- ----- ----- 16.0 2 1/2 7/8 330 CS*C400M22 5.0 57730 52140 41930 37300 28960 21790 ----- ----- ----- ----- ----- 28.2 3 1/2 7/8 455 CS*C500M22 5.0 70520 63920 51850 46370 36510 28050 ----- ----- ----- ----- ----- 28.2 3 1/2 1-1/8 475 CS*C600M22 6.5 ----- 72850 59240 53000 41670 31800 ----- ----- ----- ----- ----- 28.2 3 1/2 1-1/8 490 CS*C200L22 2.0 ----- ----- ----- ----- ----- 15930 12360 9230 7760 4930 ----- 10.0 2 1/2 7/8 340 CS*C300L22 3.0 ----- ----- ----- ----- ----- 25140 19610 14830 12620 8370 ----- 28.2 3 1/2 1-1/8 470 CS*C400L22 4.0 ----- ----- ----- ----- ----- 30010 23620 18070 15510 10580 ----- 28.2 3 1/2 1-1/8 475 CS*C500L22 5.0 ----- ----- ----- ----- ----- 34160 27100 20980 18150 12710 ----- 28.2 3 1/2 1-1/8 490 CS*C600L22 6.5 ----- ----- ----- ----- ----- 41100 32420 25090 21760 15400 ----- 28.2 3 1/2 1-1/8 500 NOTE: For 90 F ambient multiple capacity by 1.03. Reduce capacity by 3% for each 5 increase in ambient temperature. Consult factory for capacities above 110 F ambient. See rear cover for dimensional drawings ELECTRICAL DATA SEMI-HERMETIC MODELS COMP. AMPS @ 230/1/60 AMPS @ 208/230/3/60 AMPS @460/3/60 MODEL MODEL COMPRESSOR COND TOTAL MCA COMPRESSOR COND TOTAL MCA COMPRESSOR COND TOTAL MCA NUMBER NUMBER RLA LRA FLA UNIT RLA LRA FLA UNIT RLA LRA FLA UNIT CS*C300M44 06DM808 20.0 110.0 2.0 23.0 28.0 11.2 71.0 2.0 14.2 17.0 5.6 35.5 1.0 7.1 9.0 CS*C400M44 06DM313 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500M44 06DM316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 112 14.0 CS*C600M44 06DA818 ----- ----- ----- ----- ----- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 CS*C200L44 06DR109 17.1 110.0 2.0 20.1 25.0 7.6 53.3 2.0 10.6 13.0 3.5 26.3 1.0 5.0 6.0 CS*C300L44 06DR013 23.3 100.0 3.2 27.5 34.0 11.2 71.0 3.2 15.4 19.0 5.6 35.5 2.1 8.2 10.0 CS*C400L44 06DR316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500L44 06DR718 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600L44 06DR820 ----- ----- ----- ----- ----- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 CS*C300M22 06DM808 20.0 110.0 2.0 23.0 28.0 11.2 71.0 2.0 14.2 17.0 5.6 35.5 1.0 7.1 9.0 CS*C400M22 06DM313 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500M22 06DM316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600M22 06DA818 ----- ----- ----- ----- ----- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 CS*C200L22 06DR109 17.1 110.0 2.0 20.1 25.0 7.6 53.3 2.0 10.6 13.0 3.5 26.3 1.0 5.0 6.0 CS*C300L22 06DR013 23.3 100.0 3.2 27.5 34.0 11.2 71.0 3.2 15.4 19.0 5.6 35.5 2.1 8.2 10.0 CS*C400L22 06DR316 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C500L22 06DR718 28.6 150.0 3.2 32.8 40.0 17.3 100.0 3.2 21.5 26.0 8.6 50.0 2.1 11.2 14.0 CS*C600L22 06DR820 ----- ----- ----- ----- ----- 28.2 160.0 3.2 32.4 40.0 14.1 80.0 2.1 16.7 21.0 Total Unit Amps Includes approximate allowance for control circuit as follows: 1A 208/230V; 0.5A 460V. MCA (Minimum Circuit Ampacity) does not include evaporator(s) electrical requirements. (Evaporator fan motor amps, defrost heater amps) Contact factory for specific details. Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 120

PHYSICAL DIMENSIONS ALL MODELS Please contact your local Carlyle Certified Refrigeration Partner for all product, technical, sales and pricing issues. 121

MidLine Air Cooled Condensing Units 7 to 20 HP CM Series Medium to Low Temperature Units with Carlyle Semi-Hermetic Compressors The outdoor housing of our condensing units are engineered to allow easy access to all components. Quick removal of top and side panels allows quick access to everything. The hinged control panel door swings wide open for maximum clearance while the unit is being serviced. Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. The large control panel has abundant space for the controls you choose. They are intelligently arranged and laid out in a logical fashion which is easy to understand and work with. Each control and wire is clearly marked with a name or number as shown on the wiring diagram which is conveniently affixed to the control panel door. CONTROL VOLTAGE TRANSFORMER CONTROL CIRCUIT FUSES DEFROST CLOCK* RUSSAVER PRESSURE CONTROL* COMPRESSOR CONTACTOR POWER TERMINAL BLOCK EVAP FAN MOTOR CONTACTOR* BLOCK OUT RELAY* EVAPORATOR DEFROST CONTACTORS* EVAPORATOR SEQUENCING RELAYS* NON-FUSED DISCONNECT SWITCH* DOOR INTERLOCK* EVAPORATOR FAN AND HEATER SUB-CIRCUIT FUSING* CONDENSER FAN MOTOR CAPACITORS 122

MidLine MODEL NUMBER NOMENCLATURE CM LC 20 L 44 CM TYPE UNIT REFRIGERANT TYPE 22 = R-22 STYLE OF UNIT 44 = R-404A L = Outdoor unit w/flooded controls 57 = R-507 S = Outdoor unit w/ Floating Head pressure controls C = Outdoor unit w/ no head pressure controls OPERATING RANGE E = Indoor Unit H = High Temp (+10 F to +45 F Suction Temp M = High/Medium Temp (-10 F to +45 F Suctio COMPRESSOR STYLE C = Carlyle semi-hermetic NOMINAL HORSEPOWER OPTIONS: 4 year extended compressor warranty Air defrost time clock Compressor unloading Copper or coated condenser fins Crankcase pressure regulator Electric defrost components Electronic oil safety control Evaporator sub circuit fusing Fused disconnect Heated and insulated receiver - not UL Hot Gas Defrost components Liquid line solenoid valve Oil separator Oversized receiver Phase loss monitor Spring loaded relief valve Stainless steel hoses Suction line accumulator Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 123

MidLine ELECTRICAL COMPONENTS CONDENSER PIPING COMPONENTS RECEIVER HOUSING LOW AMBIENT CONTROLS TESTING MODEL FEATURES AT A GLANCE CME CMC CMS Crankcase heater OPTION STD STD Oil failure control - as required STD STD STD High-Low pressure control - manual(high)/automatic(low)rest STD STD STD Compressor contactor STD STD STD Control circuit fuses - standard 230/1 STD STD STD Power terminal block OPTION STD STD Copper tubes with Aluminum fins STD STD STD Sub-cooling circuit STD STD STD Fan motor - PSC overload protection STD STD STD Fan blade - individually balanced STD STD STD Fan guard split for easy motor access: UL listed STD STD STD Suction line filter OPTION STD STD Suction line vibration eliminator OPTION STD STD Liquid line filter/drier OPTION STD STD Sight glass/moisture indicator OPTION STD STD Discharge line vibration eliminator STD STD STD Inlet and outlet isolation valves STD STD STD Fusible plug STD STD STD All weather housing STD STD STD Control panel with hinged door STD STD STD Raised galvanized steel base STD STD STD Energy-Saver - all ambient energy saver N/A N/A STD Pressure fan cycling control (n/a on 3-6HP low temps). OPTION OPTION STD Flooded condenser OPTION OPTION N/A UL/cUL listed - all models STD STD STD Leak detection, Dielectric & Run test STD STD STD Dry nitrogen holding charge STD STD STD lease contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 124

MidLine BTUH CAPACITIES R-22 MEDIUM TEMPERATURE SUCTION TEMPERATURE F 95 AMBIENT CM*C +45 +40 +35 +25 +20 +10 06H22 100800 91000 81900 65400 58000 45000 07H22 112800 102400 92700 75400 67700 54100 08H22 126900 114300 102600 81700 72400 55900 10H22 155800 141100 127400 102800 91900 72700 15H22 204700 185500 167500 135300 121000 95700 100 AMBIENT CM*C +45 +40 +35 +25 +20 +10 06H22 97200 87700 78800 62800 55600 42900 07H22 109300 99200 89800 73000 65500 52200 08H22 122000 109800 98500 78200 69200 53300 10H22 150500 136200 122900 99100 88600 69900 15H22 197700 179000 161600 130400 116500 92000 BTUH CAPACITIES R-22 LOW TEMPERATURE SUCTION TEMPERATURE F 95 AMBIENT CM*C 0-10 -20-25 -30-35 7L22 49500 37900 28400 24200 20200 16400 8L22 58500 45000 33800 28900 24300 20000 10L22 79500 61400 45800 38700 31800 25200 12L22 85800 66700 50400 43000 36000 29100 15L22 103000 78400 57200 47400 38100 29000 20L22 128100 97100 70800 58800 47300 36100 100 AMBIENT CM*C 0-10 -20-25 -30-35 7L22 47400 36200 27100 23000 19200 15500 8L22 56100 43000 32200 27400 23000 18700 10L22 76800 59000 43600 36600 29800 23200 12L22 82800 64200 48300 40900 33800 26800 15L22 99000 74800 53900 44300 35000 26000 20L22 122800 92500 66700 54900 43600 32500 Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 125

MidLine BTUH CAPACITIES R-404A/R-507 MEDIUM TEMPERATURE SUCTION TEMPERATURE F 95 AMBIENT CM*C +45 +35 +25 +20 +10 0 06M44 107400 88300 71500 63900 50100 38200 07M44-104800 86700 78400 63400 50300 08M44 138400 113500 91500 81500 63500 48100 10M44 164100 135100 109600 98100 77600 60100 15M44 210800 176200 145100 130900 105100 82600 100 AMBIENT CM*C +45 +35 +25 +20 +10 0 06M44 102200 84000 67800 60500 47300 35900 07M44-100300 83000 75100 60700 48100 08M44 131500 107600 86600 77000 59800 45000 10M44 156100 128400 104100 93200 73600 56900 15M44 200600 167700 138000 124500 99900 78400 BTUH CAPACITIES R-404A/R-507 LOW TEMPERATURE SUCTION TEMPERATURE F 95 AMBIENT CM*C 0-10 -20-25 -30-40 07L44 54800 42400 31800 27200 22900 15500 08L44 66900 52800 40600 35000 29900 20700 10L44 84600 67400 52700 46300 40500 30400 12L44 92900 74000 57800 50700 44100 32700 15L44 118900 93800 71600 61400 52000 34800 20L44 145100 113800 86800 74900 63900 44800 100 AMBIENT CM*C 0-10 -20-25 -30-40 07L44 52200 40300 30100 25600 21500 14300 08L44 64100 50500 38600 33200 28300 19300 10L44 80400 64000 50100 44000 38400 28800 12L44 88200 70300 54800 48000 41700 30700 15L44 113500 89200 67700 57900 48700 31900 20L44 137100 107300 81500 70100 59600 41300 Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 126

MidLine MODEL NUMBER HIGH TEMP - R22 ELECTRICAL SPECIFICATIONS 230/3/60 460/3/60 COMP. COND. COMP. COND. COMPRESSOR MODEL RLA LRA FLA TOTAL UNIT AMPS MCA* RLA LRA FLA TOTAL UNIT AMPS 06H22 06DA818 28.2 160.0 6.4 35.6 43.0 14.1 80.0 3.2 17.8 22.0 07H22 06DR820 28.2 160.0 6.4 35.6 43.0 14.1 80.0 3.2 17.8 22.0 08H22 06DA825 35.6 198.0 6.4 43.0 52.0 17.8 99.0 3.2 21.5 26.0 10H22 06DR228 35.6 198.0 8.4 45.0 54.0 17.8 99.0 4.2 22.5 27.0 15H22 06DA537 57.1 266.0 8.4 66.5 81.0 25.6 120.0 4.2 30.3 37.0 LOW TEMP - R22 07L22 06DR725 28.2 160.0 6.4 35.6 43.0 14.1 80.0 3.2 17.8 22.0 08L22 06DR228 35.6 198.0 6.4 43.0 52.0 17.8 99.0 3.2 21.5 26.0 10L22 06DR337 39.7 228.0 6.4 47.1 58.0 19.9 114.0 3.2 23.6 29.0 12L22 06DR541 57.1 266.0 8.4 66.5 81.0 25.6 120.0 4.2 30.3 37.0 15L22 06ER450 72.0 283.0 8.4 81.4 100.0 36.0 142.0 4.2 40.7 50.0 20L22 06ER465 87.0 345.0 8.4 96.4 119.0 44.0 173.0 4.2 48.7 60.0 MCA* HIGH TEMP - R404A/R507 06M44 06DA818 28.2 160.0 6.4 35.6 43.0 14.1 80.0 3.2 17.8 22.0 07M44 06DR820 28.2 160.0 6.4 35.6 43.0 14.1 80.0 3.2 17.8 22.0 08M44 06DA825 35.6 198.0 6.4 43.0 52.0 17.8 99.0 3.2 21.5 26.0 10M44 06DA328 39.7 228.0 8.4 49.1 60.0 19.9 114.0 4.2 24.6 30.0 15M44 06DA537 57.1 266.0 8.4 66.5 81.0 25.6 120.0 4.2 30.3 37.0 LOW TEMP - R404A/R507 07L44 06DR725 28.2 160.0 6.4 35.6 43.0 14.1 80.0 3.2 17.8 22.0 08L44 06DR228 35.6 198.0 6.4 43.0 52.0 17.8 99.0 3.2 21.5 26.0 10L44 06DR337 39.7 228.0 6.4 47.1 58.0 19.9 114.0 3.2 23.6 29.0 12L44 06DR541 57.1 266.0 6.4 64.5 79.0 25.6 120.0 3.2 29.3 36.0 15L44 06ER450 72.0 283.0 8.4 81.4 100.0 36.0 142.0 4.2 40.7 50.0 20L44 06ER465 87.0 345.0 8.4 96.4 119.0 44.0 173.0 4.2 48.7 60.0 * Does not include evaporator loads MCA = Minimum Circuit Ampacity Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 127

MidLine PHYSICAL DATA MODEL NUMBER APPROXIMATE PHYSICAL DIMENSIONS (In) COMPRESSOR MODEL H L D CONNECTION SIZE (In) REC. CAP @ 90% LBS. LIQ. SUCT. APPROX. WEIGHT (LBS.) HIGH TEMP - R22 06H22 06DA818 37-1/4 68 48 61 8-Jul 1 8-Jan 07H22 06DR820 37-1/4 68 48 61 8-Jul 1 8-Mar 08H22 06DA825 37-1/4 68 48 61 8-Jul 1 8-Mar 10H22 06DR228 37-1/4 68 48 61 8-Jul 1 8-May 15H22 06DA537 44-3/4 68 48 96 8-Jul 1 8-May LOW TEMP - R22 07L22 06DR725 37-1/4 68 48 61 8-Jul 1 8-Mar 08L22 06DR228 37-1/4 68 48 61 8-Jul 1 8-May 10L22 06DR337 37-1/4 68 48 61 8-Jul 1 8-May 12L22 06DR541 37-1/4 68 48 61 8-Jul 1 8-May 15L22 06ER450 37-1/4 68 48 61 8-Jul 2 8-Jan 20L22 06ER465 37-1/4 68 48 96 8-Jul 2 8-Jan HIGH TEMP - R404A/R507 06M44 06DA818 37-1/4 68 48 52 8-Jul 1 8-Jan 07M44 06DR820 37-1/4 68 48 52 8-Jul 1 8-Mar 08M44 06DA825 37-1/4 68 48 52 8-Jul 1 8-Mar 10M44 06DA328 44-3/4 68 48 52 8-Jul 1 8-Mar 15M44 06DA537 44-3/4 68 48 82 8-Jul 1 8-May LOW TEMP - R404A/R507 07L44 06DR725 37-1/4 68 48 52 8-Jul 1 8-Mar 08L44 06DR228 37-1/4 68 48 52 8-Jul 1 8-May 10L44 06DR337 37-1/4 68 48 52 8-Jul 1 8-May 12L44 06DR541 37-1/4 68 48 52 8-Jul 1 8-May 15L44 06ER450 37-1/4 68 48 52 8-Jul 2 8-Jan 20L44 06ER465 44-3/4 68 48 82 8-Jul 2 8-Jan * See dimensional drawings. Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 128

DIMENSIONAL DRAWINGS INDOOR UNITS 3 68 FRONT VIEW - 2 FAN MODEL WDE H 3 3/4 43 RIGHT SIDE VIEW MODEL WDE CON D ENS E R COIL 3/4 MidLine AIR FLOW OUTDOOR UNITS 46 3/4 CONTROL BOX H CO N T RO L BO X C ONDE NSE R C O IL AIR FLOW 3 3 41 1/2 3/4 68 48 1/8 FRONT VIEW - 2 FAN MODEL WDC/WDL/WDS RIGHT SIDE VIEW MODEL WDC/WDL/WDS Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 129

MaxLine Air Cooled Condensing Units 20 to 80 HP CL Series Medium and Low Temperature Units with Carlyle Semi-Hermetic Compressors Our condensing units are designed with efficient service access in mind. Extracting just a very few screws allows complete removal of the compressor housing top panel, side panel and corner post. This gives the mechanic quick, unrestricted access to the compressor, all controls and components located within the compressor compartment. Or, only a single panel can be removed, depending upon the requirements of the service call. Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. The large control panel has abundant space for the controls you choose. They are intelligently arranged and laid out in a logical fashion which is easy to understand and work with. Each control and wire is clearly marked with a name or number as shown on the wiring diagram which is conveniently affixed to the control panel door. CONTROL VOLTAGE TRANSFORMER CONTROL CIRCUIT FUSES DEFROST CLOCK* ENERGY SAVER PRESSURE CONTROL* COMPRESSOR CONTACTOR POWER TERMINAL BLOCK EVAP FAN MOTOR CONTACTOR* BLOCK OUT RELAY* EVAPORATOR DEFROST CONTACTORS* EVAPORATOR SEQUENCING RELAYS* NON-FUSED DISCONNECT SWITCH* DOOR INTERLOCK* EVAPORATOR FAN AND HEATER SUB-CIRCUIT FUSING* CONDENSER FAN MOTOR CAPACITORS 130

MaxLine MODEL NUMBER NOMENCLATURE CL L C 20 H 22 CL TYPE LARGE UNIT REFRIGERANT TYPE 22 = R-22 STYLE OF UNIT 44 = R-404A L = Outdoor unit w/flooded controls 57 = R-507 S = Outdoor unit w/ Floating Head pressure controls C = Outdoor unit w/ no head pressure controls OPERATING RANGE H = High Temp (+10 F to +45 F Suction Temp M = High/Medium Temp (-10 F to +45 F Suctio L = Low Temp (-40 F to 0 F Suction Temp) COMPRESSOR STYLE C = Carlyle semi-hermetic NOMINAL HORSEPOWER OPTIONS: 4 year extended compressor warranty Air defrost time clock Compressor unloading Oil separator Copper or coated condenser fins Crankcase pressure regulator Electric defrost components Electronic oil safety control Evaporator sub circuit fusing Fused disconnect Heated and insulated receiver - not UL Hot Gas Defrost components Liquid line solenoid valve Oversized receiver Phase loss monitor Spring loaded relief valve Stainless steel hoses Suction line accumulator Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 131

MaxLine ELECTRICAL COMPONENTS CONDENSER PIPING COMPONENTS RECEIVER HOUSING LOW AMBIENT CONTROLS TESTING MODEL FEATURES AT A GLANCE CLS CLL CLS Crankcase heater STD STD STD Oil failure control - as required STD STD STD High-Low pressure control - manual(high)/automatic(low)rest STD STD STD Compressor contactor STD STD STD Control circuit fuses - standard 230/1 STD STD STD Power terminal block STD STD STD Copper tubes with Aluminum fins STD STD STD Sub-cooling circuit STD STD STD Fan motor - PSC overload protection STD STD STD Fan blade - individually balanced STD STD STD Fan guard - Heavy duty resilient wire basket STD STD STD Suction line filter (replaceable core - some models) STD STD STD Suction line vibration eliminator STD STD STD Replaceable core liquid line filter/drier STD STD STD Sight glass/moisture indicator STD STD STD Discharge line vibration eliminator STD STD STD High pressure control hoses STD STD STD Pressure relief device STD STD STD Inlet and outlet isolation valves STD STD STD Mill finish galvanized steel with removable access panels STD STD STD Raised galvanized steel base STD STD STD All ambient energy saver N/A N/A STD Pressure fan cycling control STD STD N/A Flooded condenser N/A STD N/A UL/cUL listed - all models STD STD STD Leak detection, Dielectric & Run test STD STD STD Dry nitrogen holding charge STD STD STD Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 132

MaxLine BTUH CAPACITIES R-22 MEDIUM TEMP - SINGLE COMPRESSOR SUCTION TEMPERATURE F 95 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 20H22 209500 170900 137700 122900 97000 75300 25H22 277300 227300 183700 164300 129700 100500 30H22 362100 293500 234300 208200 162000 123700 35H22 400700 326900 262500 233700 182100 138100 40H22 519000 425300 344100 308000 244000 190200 100 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 20H22 202300 164900 132700 118400 93200 72200 25H22 267300 218800 176600 157800 124400 96100 30H22 348400 281900 224800 199500 154900 117900 35H22 387000 315100 252300 224200 173900 131000 40H22 501700 410700 332000 296900 234900 182800 BTUH CAPACITIES R-22 MEDIUM TEMP - Parallel / Dual SUCTION TEMPERATURE F 95 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 17H22/18H22 268400 215600 170500 150600 115800 87000 21H22/23H22 319500 258200 206000 183000 142700 109500 31H22/32H22 433500 351900 282300 251500 197700 153000 51H22/52H22 576900 470300 378400 337600 265500 205000 61H22/62H22 761900 613400 486800 431100 333800 253600 71H22/72H22 827900 673500 539500 479700 373100 282400 81H22/82H22 1079200 879600 708300 632600 499100 387800 100 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 17H22/18H22 258200 207000 163300 144000 110400 82500 21H22/23H22 308000 248600 198000 175800 136900 104700 31H22/32H22 418700 339600 272000 242300 190100 146800 51H22/52H22 556200 452900 363900 324400 254600 196000 61H22/62H22 733300 589400 466900 413100 319100 241600 71H22/72H22 800600 649800 519100 460600 356600 268100 81H22/82H22 1043700 849800 683500 610000 480600 372700 Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 133

MaxLine BTUH CAPACITIES R-404A / R-507 - MEDIUM TEMP Single Compressor SUCTION TEMPERATURE F 95 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 20M44 219200 182000 149100 134100 107300 84000 25M44 293300 241600 196100 175600 138900 107500 30M44 368800 305700 248800 222600 174500 131900 35M44 431100 356300 289900 259800 205700 158900 40M44 511000 440400 378400 350300 299300 254200 100 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 20M44 209100 173600 142100 127800 102100 79800 25M44 278700 229500 186200 166700 131700 101700 30M44 350300 290000 235600 210400 164300 123300 35M44 409500 338300 275200 246600 194900 150200 40M44 483600 416700 357600 330900 282200 239000 BTUH CAPACITIES R-404A/R-507 - MEDIUM TEMP Parallel/Dual SUCTION TEMPERATURE F 95 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 17M44/18M44 293800 239000 191300 169800 131600 99100 21M44/23M44 347100 283200 227900 203400 159900 123200 31M44/32M44 462500 380900 309800 277900 220900 172300 51M44/52M44 566800 459100 366500 325500 287800 221400 61M44/62M44 723400 588500 469700 415900 365700 275100 71M44/72M44 835300 678100 542200 481700 425800 327000 81M44/82M44 1101600 941100 802200 740100 628600 531500 100 AMBIENT CLC/CLL/CLS +45 +35 +25 +20 +10 0 17M44/18M44 279800 227200 181300 160700 124100 92800 21M44/23M44 330900 269800 216900 193400 151800 116700 31M44/32M44 442700 364300 296000 265300 210600 163800 51M44/52M44 539900 436900 348300 309100 273000 209500 61M44/62M44 688500 559100 445000 393200 344900 257400 71M44/72M44 794400 644500 514900 457200 403900 309300 81M44/82M44 1049000 895300 762300 702700 595700 502100 Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 134

MaxLine MODEL NUMBER ELECTRICAL SPECIFICATIONS - SINGLE AND PARALLEL COMPRESSOR MODELS 230/3/60 460/3/60 COMP. COND. COMP. COND. COMPRESSOR MODEL RLA LRA FLA TOTAL UNIT AMPS MCA* RLA LRA FLA TOTAL UNIT AMPS MEDIUM TEMP - R22 20H22 06DA537 57.1 266 12.8 70.9 86 25.6 120 6.4 32.5 39 25H22 06EA550 87 345 12.8 100.8 123 44 173 6.4 50.9 62 30H22 06EA565 112 446 12.8 125.8 154 56 223 6.4 62.9 77 35H22 06EA575 135 506 19.2 155.2 189 68 253 9.6 78.1 96 40H22 06EA599 189 690 19.2 209.2 257 95 345 9.6 105.1 129 17H22 (2)06DA825 71.2 396 12.8 85 103 35.6 198 6.4 42.5 52 21H22 (2)06DA328 79.4 456 12.8 93.2 114 39.8 228 6.4 46.7 57 31H22 (2)06DA537 114.2 532 19.2 134.4 163 51.2 240 9.6 61.3 75 51H22 (2)06EA550 174 690 25.6 200.6 245 88 346 12.8 101.3 124 61H22 (2)06EA565 224 892 25.6 250.6 307 112 446 12.8 125.3 154 71H22 (2)06EA575 270 1012 38.4 309.4 377 136 506 19.2 155.7 190 81H22 (2)06EA599 378 1380 38.4 417.4 512 190 690 19.2 209.7 258 MCA* LOW TEMP - R22 25L22 06ER475 87 345 12.8 100.8 123 44 173 6.4 50.9 62 30L22 06ER399 135 506 12.8 148.8 183 68 253 6.4 74.9 92 44L22 (2)06ER465 174 690 19.2 194.2 238 88 346 9.6 98.1 121 54L22 (2)06ER475 174 690 19.2 194.2 238 88 346 9.6 98.1 121 61L22 (2)06ER399 270 1012 19.2 290.2 358 136 506 9.6 146.1 181 MEDIUM TEMP - R404A/R507 20M44 06DA537 57.1 266 12.8 70.9 86 25.6 120 6.4 32.5 39 25M44 06EA550 87 345 12.8 100.8 123 44 173 6.4 50.9 62 30M44 06EA565 112 446 12.8 125.8 154 56 223 6.4 62.9 77 35M44 06EA575 135 506 19.2 155.2 189 68 253 9.6 78.1 96 40M44 06EA599 189 690 19.2 209.2 257 95 345 9.6 105.1 129 17M44 (2)06DA825 71.2 396 12.8 85 103 35.6 198 6.4 42.5 52 21M44 (2)06DA328 79.4 456 12.8 93.2 114 39.8 228 6.4 46.7 57 31M44 (2)06DA537 114.2 532 19.2 134.4 163 51.2 240 9.6 61.3 75 51M44 (2)06EA550 174 690 25.6 200.6 245 88 346 12.8 101.3 124 61M44 (2)06EA565 224 892 25.6 250.6 307 112 446 12.8 125.3 154 71M44 (2)06EA575 270 1012 38.4 309.4 377 136 506 19.2 155.7 190 81M44 (2)06EA599 378 1380 38.4 417.4 512 190 690 19.2 209.7 258 LOW TEMP - R404A/R507 25L44 06ER475 87 345 12.8 100.8 123 44 173 6.4 50.9 62 30L44 06ER399 135 506 12.8 148.8 183 68 253 6.4 74.9 92 44L44 (2)06ER465 174 690 19.2 194.2 238 88 346 9.6 98.1 121 54L44 (2)06ER475 174 690 19.2 194.2 238 88 346 9.6 98.1 121 61L44 (2)06ER399 270 1012 19.2 290.2 358 136 506 9.6 146.1 181 * Does not include evaporator loads MCA = Minimum Circuit Ampacity Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 135

MaxLine MODEL NUMBER ELECTRICAL SPECIFICATIONS - DUAL COMPRESSOR MODELS 230/3/60 460/3/60 COMP. COND. COMP. COND. COMPRESSOR MODEL RLA LRA FLA TOTAL UNIT AMPS MCA* RLA LRA FLA TOTAL UNIT AMPS HIGH TEMP - R22 18H22 (2)06DA825 35.6 198 12.8 49.4 103 17.8 99 6.4 24.7 52 23H22 (2)06DA328 39.7 228 12.8 53.5 114 19.9 114 6.4 26.8 57 32H22 (2)06DA537 57.1 266 19.2 77.3 163 25.6 120 9.6 35.7 75 52H22 (2)06EA550 87 345 25.6 113.6 245 44 173 12.8 57.3 124 62H22 (2)06EA565 112 446 25.6 138.6 307 56 223 12.8 69.3 154 72H22 (2)06EA575 135 506 38.4 174.4 377 68 253 19.2 87.7 190 82H22 (2)06EA599 189 690 38.4 228.4 512 95 345 19.2 114.7 258 LOW TEMP - R22 46L22 (2)06ER465 87 345 19.2 107.2 238 44 173 9.6 54.1 121 56L22 (2)06ER475 87 345 19.2 107.2 238 44 173 9.6 54.1 121 62L22 (2)06ER399 135 506 19.2 155.2 358 68 253 9.6 78.1 181 MCA* HIGH TEMP - R404A/R507 18M44 (2)06DA825 35.6 198 12.8 49.4 103 17.8 99 6.4 24.7 52 23M44 (2)06DA328 39.7 228 12.8 53.5 114 19.9 114 6.4 26.8 57 32M44 (2)06DA537 57.1 266 19.2 77.3 163 25.6 120 9.6 35.7 75 52M44 (2)06EA550 87 345 25.6 113.6 245 44 173 12.8 57.3 124 62M44 (2)06EA565 112 446 25.6 138.6 307 56 223 12.8 69.3 154 72M44 (2)06EA575 135 506 38.4 174.4 377 68 253 19.2 87.7 190 82M44 (2)06EA599 189 690 38.4 228.4 512 95 345 19.2 114.7 258 LOW TEMP - R404A/R507 46L44 (2)06ER465 87 345 19.2 107.2 238 44 173 9.6 54.1 121 56L44 (2)06ER475 87 345 19.2 107.2 238 44 173 9.6 54.1 121 62L44 (2)06ER399 135 506 19.2 155.2 358 68 253 9.6 78.1 181 * Does not include evaporator loads MCA = Minimum Circuit Ampacity Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 136

MaxLine MODEL NUMBER PHYSICAL DATA - SINGLE AND PARALLEL COMPRESSOR MODELS COMPRESSOR MODEL APPROXIMATE PHYSICAL DIMENSIONS (In) QTY* COND FANS H L D FAN* CONFIG. CONNECTION SIZE (In) REC. CAP @ 90% LBS. LIQ. SUCT. APPROX. WEIGHT (LBS.) HIGH TEMP - R22 20H22 06DA537 2 150-3/4 45-3/4 41-1/2 A 106 7/8 1-5/8 1925 25H22 06EA550 2 150-3/4 45-3/4 41-1/2 A 144 7/8 2-1/8 2000 30H22 06EA565 2 150-3/4 45-3/4 41-1/2 A 182 1-1/8 2-1/8 2140 35H22 06EA575 3 198-3/4 45-3/4 41-1/2 B 220 1-1/8 2-1/8 2385 40H22 06EA599 3 198-3/4 45-3/4 41-1/2 B 295 1-1/8 2-1/8 2525 17H22 (2)06DA825 2 185 45-3/4 75-3/4 A 144 7/8 2-1/8 2450 21H22 (2)06DA328 2 185 45-3/4 75-3/4 A 144 7/8 2-1/8 2575 31H22 (2)06DA537 3 233 45-3/4 75-3/4 B 220 1-1/8 2-1/8 3050 51H22 (2)06EA550 4 150-3/4 90-3/4 41-1/2 C 295 1-1/8 2-5/8 3500 61H22 (2)06EA565 4 150-3/4 90-3/4 41-1/2 C 295 1-3/8 2-5/8 3710 71H22 (2)06EA575 6 198-3/4 90-3/4 41-1/2 D 416 1-5/8 3-1/8 4340 81H22 (2)06EA599 6 198-3/4 90-3/4 41-1/2 D 500 1-5/8 3-1/8 4750 LOW TEMP - R22 25L22 06ER475 2 150-3/4 45-3/4 41-1/2 A 145 7/8 2-1/8 2000 30L22 06ER399 2 150-3/4 45-3/4 41-1/2 A 145 7/8 2-1/8 2065 44L22 (2)06ER465 3 233 45-3/4 75-3/4 B 220 1-1/8 3-1/8 2800 54L22 (2)06ER475 3 233 45-3/4 75-3/4 B 295 1-1/8 3-1/8 3280 61L22 (2)06ER399 3 233 45-3/4 75-3/4 B 295 1-1/8 3-1/8 3580 HIGH TEMP - R404A/R507 20M44 06DA537 2 150-3/4 45-3/4 41-1/2 A 94 7/8 1-5/8 1925 25M44 06EA550 2 150-3/4 45-3/4 41-1/2 A 128 7/8 2-1/8 2000 30M44 06EA565 2 150-3/4 45-3/4 41-1/2 A 162 1-1/8 2-1/8 2140 35M44 06EA575 3 198-3/4 45-3/4 41-1/2 B 195 1-1/8 2-1/8 2385 40M44 06EA599 3 198-3/4 45-3/4 41-1/2 B 262 1-1/8 2-1/8 2525 17M44 (2)06DA825 2 185 45-3/4 75-3/4 A 128 7/8 2-1/8 2450 21M44 (2)06DA328 2 185 45-3/4 75-3/4 A 128 7/8 2-1/8 2575 31M44 (2)06DA537 3 233 45-3/4 75-3/4 B 195 1-1/8 2-1/8 3050 51M44 (2)06EA550 4 150-3/4 90-3/4 41-1/2 C 262 1-1/8 2-5/8 3500 61M44 (2)06EA565 4 150-3/4 90-3/4 41-1/2 C 262 1-3/8 2-5/8 3710 71M44 (2)06EA575 6 198-3/4 90-3/4 41-1/2 D 370 1-5/8 3-1/8 4340 81M44 (2)06EA599 6 198-3/4 90-3/4 41-1/2 D 445 1-5/8 3-1/8 4750 LOW TEMP - R404A/R507 25L44 06ER475 2 150-3/4 45-3/4 41-1/2 A 128 7/8 2-1/8 2000 30L44 06ER399 2 150-3/4 45-3/4 41-1/2 A 145 7/8 2-1/8 2065 44L44 (2)06ER465 3 233 45-3/4 75-3/4 B 195 1-1/8 3-1/8 2800 54L44 (2)06ER475 3 233 45-3/4 75-3/4 B 262 1-1/8 3-1/8 3280 61L44 (2)06ER399 3 233 45-3/4 75-3/4 B 262 1-1/8 3-1/8 3580 * See back cover for dimensional drawings. Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 137

MaxLine MODEL NUMBER COMPRESSOR MODEL PHYSICAL DATA - DUAL COMPRESSOR MODELS APPROXIMATE PHYSICAL DIMENSIONS (In) QTY* COND FANS H L D FAN* CONFIG. CONNECTION SIZE (In) REC. CAP @ 90% LBS. LIQ. SUCT. APPROX. WEIGHT (LBS.) HIGH TEMP - R22 18H22 (2)06DA825 2 185 45-3/4 75-3/4 A (2)62 (2)7/8 (2)1-3/8 2450 23H22 (2)06DA328 2 185 45-3/4 75-3/4 A (2)62 (2)7/8 (2)1-5/8 2575 32H22 (2)06DA537 3 233 45-3/4 75-3/4 B (2)106 (2)1-1/8 (2)1-5/8 3050 52H22 (2)06EA550 4 150-3/4 90-3/4 41-1/2 C (2)144 (2)1-1/8 (2)2-1/8 3500 62H22 (2)06EA565 4 150-3/4 90-3/4 41-1/2 C (2)182 (2)1-3/8 (2)2-1/8 3710 72H22 (2)06EA575 6 198-3/4 90-3/4 41-1/2 D (2)220 (2)1-5/8 (2)2-1/8 4340 82H22 (2)06EA599 6 198-3/4 90-3/4 41-1/2 D (2)295 (2)1-5/8 (2)2-1/8 4750 LOW TEMP - R22 46L22 (2)06ER465 3 233 45-3/4 75-3/4 B (2)106 (2)1-1/8 (2)2-1/8 2800 56L22 (2)06ER475 3 233 45-3/4 75-3/4 B (2)144 (2)1-1/8 (2)2-1/8 3280 62L22 (2)06ER399 3 233 45-3/4 75-3/4 B (2)144 (2)1-1/8 (2)2-1/8 3580 HIGH TEMP - 404A/R507 18M44 (2)06DA825 2 185 45-3/4 75-3/4 A (2)55 (2)7/8 (2)1-3/8 2450 23M44 (2)06DA328 2 185 45-3/4 75-3/4 A (2)55 (2)7/8 (2)1-5/8 2575 32M44 (2)06DA537 3 233 45-3/4 75-3/4 B (2)94 (2)1-1/8 (2)1-5/8 3050 52M44 (2)06EA550 4 150-3/4 90-3/4 41-1/2 C (2)128 (2)1-1/8 (2)2-1/8 3500 62M44 (2)06EA565 4 150-3/4 90-3/4 41-1/2 C (2)162 (2)1-3/8 (2)2-1/8 3710 72M44 (2)06EA575 6 198-3/4 90-3/4 41-1/2 D (2)195 (2)1-5/8 (2)2-1/8 4340 82M44 (2)06EA599 6 198-3/4 90-3/4 41-1/2 D (2)262 (2)1-5/8 (2)2-1/8 4750 LOW TEMP - 404A/R507 46L44 (2)06ER465 3 233 45-3/4 75-3/4 B (2)94 (2)1-1/8 (2)2-1/8 2800 56L44 (2)06ER475 3 233 45-3/4 75-3/4 B (2)128 (2)1-1/8 (2)2-1/8 3280 62L44 (2)06ER399 3 233 45-3/4 75-3/4 B (2)128 (2)1-1/8 (2)2-1/8 3580 * See back cover for dimensional drawings. Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 138

DRAWINGS 50 3/4 50 6 5 5 22 1/2 W CO NT RO L B O X CO NT RO L B O X PIPING PIPING FAN CONFIGURATION "A" 12 CONTROL BOX FAN CONFIGURATION "B" CONTROL BOX A L ALL PIPING CONNECTIONS ALL PIPING CONNECTIONS 20 MaxLine 2-1/2 Dia Lifting Holes 20 6 3/4 22 1/2 W 12 6 A L 2-1/2 Dia Lifting Holes 5 FAN CONFIGURATION "C" 50 6 3/4 50 5 44 1/2 W CO NT RO L B O X CO NT RO L B O X CONTROL BOX PIPING 12 A FAN CONFIGURATION "D" CONTROL BOX PIPING ALL PIPING CONNECTIONS L ALL PIPING CONNECTIONS 20 2-1/2 Dia Lifting Holes 20 6 3/4 44 1/2 W 12 6 A L 2-1/2 Dia Lifting Holes Please contact your local Carlyle Certified Refrigeration Partner for all Product, technical, sales and pricing issues. 139

PARTS 140

141

142

143

144

LARGE PROFILE - MODELS HW*U, HW*L, HW*M, HWAH MODEL NUMBER DESCRIPTION PART NUMBER ALL MODELS DEFROST CONTROL, ADJUSTABLE, RANCO F-25 204464037 ALL 1 FAN MODELS DEFROST HEATERS, CORE, 1378 WATTS, 40" LENGTH, 208-230/460 V. (4 REQ'D) 206240003 DEFROST HEATERS, CORE, 1378 WATTS, 40" LENGTH,575 V. (4 REQ'D) 206240025 ALL 2 FAN MODELS DEFROST HEATERS, CORE, 2458 WATTS, 70" LENGTH, 208-230/460 V. (4 REQ'D) 206240004 DEFROST HEATERS, CORE, 2458 WATTS, 70" LENGTH, 575 V. (4 REQ'D) 206240026 ALL 3 FAN MODELS DEFROST HEATERS, CORE, 3538 WATTS, 100" LENGTH, 208-230/460 V. (4 REQ'D) 206240005 DEFROST HEATERS, CORE, 3538 WATTS, 100" LENGTH, 575 V. (4 REQ'D) 206240027 HWEU4-711 DEFROST HEATERS, CORE, 2305 WATTS, 132" LENGTH, 208-230/460 V. (8 REQ'D) 206240002 HWEL4-817, HWEL4-722 DEFROST HEATERS, CORE, 2305 WATTS, 132" LENGTH, 575 V. (8 REQ'D) 206240024 HWEM4-780, HWEM4-882 HWEU4-851, HWEU4-1080, DEFROST HEATERS, CORE, 2305 WATTS, 132" LENGTH, 208-230/460 V. (12 REQ'D) 206240002 DEFROST HEATERS, CORE, 2305 WATTS, 132" LENGTH, HWEL4-950, 4-1100, 4-1260, (12 REQ'D) 206240024 575 V. HWEL4-1380, HWEM4-1100 HWEM4-1320, HWEM4-1656 HWEU5-1350, HWEL5-1575 DEFROST HEATERS, CORE, 2837 WATTS, 162" LENGTH, 208-230/460 V. (12 REQ'D) 206240017 HWEL5-1725, HWEM5-2065 DEFROST HEATERS, CORE, 2837 WATTS, 162" LENGTH, 575 V. (12 REQ'D) NLA HWEU6-1620, HWEL6-1890 DEFROST HEATERS, CORE, 3369 WATTS, 192" LENGTH, 208-230/460 V. (12 REQ'D) 206240018 HWEL6-2070, HWEM6-2480 DEFROST HEATERS, CORE, 3369 WATTS, 192" LENGTH, 575 V. (12 REQ'D) NLA ALL MODELS DEFROST HEATER, DRAIN PLUG, 27 WATTS, 208-230/460 V. 107807003 DRAIN PANS ** (contact factory for Hot Gas Pans) 1 FAN MODELS DRAIN PAN, 46-1/2"LENGTH - (SHIPS FR YUMA, AZ) SPECIFY MOD# AND S/N. 10642401 2 FAN MODELS DRAIN PAN, 76-1/2"LENGTH - (SHIPS FR YUMA, AZ) SPECIFY MOD# AND S/N. 10642402 3 FAN MODELS DRAIN PAN, 106-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 10642403 4 FAN MODELS (AIR DEFROST) DRAIN PAN, 136-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 10642404 5 FAN MODELS (AIR DEFROST) DRAIN PAN, 166-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 21884500 6 FAN MODELS (AIR DEFROST) DRAIN PAN, 196-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 21884600 4 FAN MODELS (ELEC. DEF) DRAIN PAN, 136-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 21485900 5 FAN MODELS (ELEC. DEF) DRAIN PAN, 166-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 21512700 6 FAN MODELS (ELEC. DEF) DRAIN PAN, 196-1/2"LENGTH - (SHIPS FROM YUMA, AZ) SPECIFY MOD# AND S/N. 21505600 4,5,6, FAN MODELS DRAIN PAN,CONNECTION 1-1/4" 114896001 DRAIN PAN HEATERS** 1-3 FAN MODELS* NOT AVAILABLE NLA 4 FAN MODELS DRAIN PAN HEATER, 133-1/2"LENGTH, SPEC. MOD# AND S/N. ( 2 REQ.), 540 WATTS 115098000 5 FAN MODELS DRAIN PAN HEATER, 163-1/2"LENGTH, SPEC. MOD# AND S/N. ( 2 REQ.), 660 WATTS 115099000 6 FAN MODELS DRAIN PAN HEATER, 196-1/2"LENGTH, SPEC. MOD# AND S/N. ( 2 REQ.), 780 WATTS 115100000 145

146

147

148

149

150

FAN BLADES HW*U1-118, HW*U2-236, HW*L1-125 FAN BLADES, 20" DIAM., 23 PITCH, CCW, 1/2" BORE 202147008 HW*L1-152, HW*L1-193, HW*L2-240, HW*L2-304 HW*U2-355, HW*L2-361, HW*L2-408, FAN BLADES, 24" DIAM., 32 PITCH, CW, 1/2" BORE 213455000 HW*M4-1100, HW*M4-1320, HW*M4-1656, HWAH4-1452, HWAH4-1821, HWAH5-2275, HWAH6-2730, & ALL 3, 4, 5, & 6 FAN HW*U AND HW*L MODELS HW*M1-164, HW*M1-209, HW*M2-270, FAN BLADES, 20" DIAM., 25 PITCH, CW, 1/2" BORE 213456000 HW*M2-239, HWAH1-182, HWAH1-232, HWAH2-300, HWAH2-365 HW*M2-390, 2-441, HWAH2-433, FAN BLADES, 24" DIAM., 14 PITCH, CW, 1/2" BORE 214041000 HWAH2-490, ALL 3 FAN HW*M, AND HWAH MODELS HW*M4-780, HW*M4-882, HW*M5-2065, HW*M6-2480, HWAH4-866, 4-980, 4-1100 HW*U1-118, HW*U2-236, HW*L1-125, FAN GUARD, WIRE, EPOXY COATED, 20" 213484000 HW*L1-152, HW*L1-193, HW*L2-240, HW*L2-304, HW*M1-164, HW*M1-209, FAN GUARD, AIR STRAIGHTENER (20" FANS) 10692300 HW*M2-270, 2-329, HWAH1-182, HWAH1-232, HWAH2-300, 2-365 HW*U2-355, HW*L2-361, HW*L2-408, FAN GUARD, WIRE, EPOXY COATED, 24" 202136005 HW*M2-390, 2-441, HWAH2-433, HWAH2-490, & ALL 3, 4, 5, 6 FAN FAN GUARD, AIR STRAIGHTENER (24" FANS) 10709900 HW*U,HW*L,HW*M,HWAH MODELS REPLACEMENT TECUMSEH COMPRESSORS FOR CARRIER HERMETIC UNITS RCD P/N CARRIER MODEL NO RCD P/N CARRIER MODEL NO 312332057 CSLU075L44-D 312332058 CSLU100L44-D 312332070 CSLU125H22-D 312332068 CSLU050H22-D 312332069 CSLU075H22-D 312332056 CSLU050L44-D 312332077 CSLU250H22-D 312332078 CSLU250H22-E 312332080 CSLU300H22-D 312332081 CSLU300H22-E 312332084 CSLU400H22-E 312332065 CSLU300L44-D 312332066 CSLU300L44-E 312332087 CSLU500H22-E 312332086 CSLU500H22-D 312332062 CSLU200L44-D 312332063 CSLU200L44-E 312332044 CSLU200M44-D 312332048 CSLU200M44-E 312332041 CSLU150M44-D 312332059 CSLU150L44-D 312332060 CSLU150L44-E 312332071 CSLU150H22-D 312332072 CSLU150H22-E 312332074 CSLU200H22-D 312332075 CSLU200H22-E 151