Particle Size Analysis



Similar documents
LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008

Fluid Mechanics: Static s Kinematics Dynamics Fluid

Molysulfide. Particle Size Analysis

XI / PHYSICS FLUIDS IN MOTION 11/PA

POWDER PROPERTIES LABORATORY

Particle size measurement of lactose for dry powder inhalers

IVHHN GUIDELINES FOR GRAIN-SIZE DISTRIBUTION ANALYSIS

GUIDANCE DOCUMENT ON THE DETERMINATION OF PARTICLE SIZE DISTRIBUTION, FIBRE LENGTH AND DIAMETER DISTRIBUTION OF CHEMICAL SUBSTANCES

Method Development and Validation for Particle Size and Shape Measurements

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

PARTICLE SIZE AND SIZE DISTRIBUTION OF SUPERABRASIVE POWDERS ION C. BENEA, Ph.D. Engis Corporat ion

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

Particle motion, particle size, and aerodynamic diameter

ICH Topic Q4B Annex 5 Disintegration Test General Chapter. Step 3

Single Mode Fiber Lasers

BASIC PRINCIPLES OF PARTICLE

Laser sintering of greens compacts of MoSi 2

Acoustic GHz-Microscopy: Potential, Challenges and Applications

INTRODUCTION SOME USES OF SPRAY NOZZLES INTRODUCTION TYPES OF SPRAY NOZZLES

Math Matters: Dissecting Hydrometer Calculations

The Basic Principles of Sieve Analysis

Solid State Detectors = Semi-Conductor based Detectors

Encoders for Linear Motors in the Electronics Industry

Bruce B. Weiner, Walther W. Tscharnuter, David Fairhurst Brookhaven Instruments Corporation Holtsville, NY US

Lecture 24 - Surface tension, viscous flow, thermodynamics

View of ΣIGMA TM (Ref. 1)

Basic Principles in Microfluidics

Flow Sensors. - mass flow rate - volume flow rate - velocity. - stream line parabolic velocity profile - turbulent vortices. Methods of measurement

Laminar and Turbulent flow. Flow Sensors. Reynolds Number. Thermal flow Sensor. Flow and Flow rate. R = Mass Flow controllers

TOF FUNDAMENTALS TUTORIAL

Millikan Oil Drop Experiment Matthew Norton, Jurasits Christopher, Heyduck William, Nick Chumbley. Norton 0

ISO A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

2 Particle characterisation

A GUIDEBOOK TO PARTICLE SIZE ANALYSIS

Using light scattering method to find The surface tension of water

Various Technics of Liquids and Solids Level Measurements. (Part 3)

PARTICLE SIZES EXPLAINED

MEMS mirror for low cost laser scanners. Ulrich Hofmann

FLUID FLOW STREAMLINE LAMINAR FLOW TURBULENT FLOW REYNOLDS NUMBER

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Thermal diffusivity and conductivity - an introduction to theory and practice

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Robot Perception Continued

1. Fluids Mechanics and Fluid Properties. 1.1 Objectives of this section. 1.2 Fluids

Ultrasonic Wave Propagation Review

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

PARTICLE SIZE. By: Philo Morse, MS, and Andrew Loxley, PhD. INTRODUCTION are not as stringent as for scattering techniques.

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

Ferroxcube. For more information on Product Status Definitions, see page Sep CBW625

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

RAY TRACING UNIFIED FIELD TRACING

THE USE OF AIR ATOMIZING NOZZLES TO PRODUCE SPRAYS WITH FINE DROPLETS

Acceleration due to Gravity

Efficiency, Dispersion and Straylight Performance Tests of Immersed Gratings for High Resolution Spectroscopy in the Near Infra-red

Particle Measurement Technology in Practice. From Theory to Application.

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Ch 2 Properties of Fluids - II. Ideal Fluids. Real Fluids. Viscosity (1) Viscosity (3) Viscosity (2)

In mathematics, there are four attainment targets: using and applying mathematics; number and algebra; shape, space and measures, and handling data.

Single Photon Counting Module COUNT -Series

AS COMPETITION PAPER 2008

Natural Convection. Buoyancy force

Owner s Manual

Setting Size Specifications

E190Q Lecture 5 Autonomous Robot Navigation

Acousto-optic modulator

Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment

7. DYNAMIC LIGHT SCATTERING 7.1 First order temporal autocorrelation function.

The Viscosity of Fluids


Lecture 5 Hemodynamics. Description of fluid flow. The equation of continuity

ME 538: Experiment # 1 Flow measurement and particle generation instruments

Experiment 5. Lasers and laser mode structure

ENGINEERING METROLOGY

IN-LINE PARTICLE SIZE MEASUREMENTS FOR CEMENT AND OTHER ABRASIVE PROCESS ENVIRONMENTS

A NEW LOOK AT RISLEY PRISMS. By Craig Schwarze Senior Systems Engineer OPTRA Inc.

A Guide to Acousto-Optic Modulators

Operation Manual For NDJ-8S Digital Rotary Viscometer

Applications of confocal fluorescence microscopy in biological sciences

Science Standard Articulated by Grade Level Strand 5: Physical Science

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

The Basics of Scanning Electron Microscopy

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

1) The time for one cycle of a periodic process is called the A) wavelength. B) period. C) frequency. D) amplitude.

Lapping and Polishing Basics

<788> PARTICULATE MATTER IN INJECTIONS

Care and Use of the Compound Microscope

BACTERIAL ENUMERATION

FOOD ENGINEERING Vol. I - Particle Size Distribution in Food Powders - Gustavo V. Barbosa-Cánovas, Federico Harte and Hong Helen Yan

SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II

MEASUREMENT OF VISCOSITY OF LIQUIDS BY THE STOKE S METHOD

Leidenfrost effect. Scott Schollenberger. MCEN 5228: Flow Visualization

11. NONDESTRUCTIVE TESTING

Stainless Steel Marking Guide

Transcription:

Particle Size Analysis Why measure particle size of pharmaceuticals??? Particle size can affect Processability of powder (API or excipient) Flow, mixing, compaction Final formulation: performance, appearance, stability 1

Methods for Determining Particle Size Microscopy Sieving Sedimentation techniques Optical and electrical sensing zone method Laser light scattering techniques [Surface area measurement techniques] 2

Choosing a Method for Particle Size Analysis Nature of the material to be sized, e.g. Estimated particle size and particle size range Solubility Ease of handling Toxicity Flowability Intended use Cost Capital Running Specification requirements Time restrictions 3

Microscopy Optical microscopy (1µm- mm) Electron microscopy (0.001µ-) Number distribution Being able to examine each particle individually has led to microscopy being considered as an absolute measurement of particle size. Can distinguish aggregates from single particles Can be coupled to image analysis computers,each field can be examined, and a distribution obtained. Most severe limitation of optical microscopy is the depth of focusbeing about 10µm at x100 and only 0.5µm at x1000. With small particles, diffraction effectsincrease causing blurring at the edges -determination of particles < 3µm is less and less certain. 4

Submicron particles For submicron particles it is necessary to use either TEM(Transmission Electron Microscopy) or SEM (Scanning Electron Microscopy) 5

Diameters Measured Martin's diameter (M) The length of the line which bisects the particle image. The lines may be drawn in any direction which must be maintained constant for all image measurements. Feret's diameter (F) is the distance between two tangents on opposite sides of the particle, parallel to some fixed direction. Projected area diameter (d a or d p ) is the diameter of a circle having the same area as the particle viewed normally to the plane surface on which the particle is at rest in a stable position. Others: Longest dimension: a measured diameter equal to the maximum value of Feret's diameter. Perimeter diameter: the diameter of a circle having the same circumference as the perimeter of the particle. Maximum chord: a diameter equal to the maximum length of a line parallel to some fixed direction and limited by the contour of the particle. 6

Manual Optical Microscopy Advantages Relatively inexpensive Each particle individually examined -detect aggregates, 2D shape, colour, melting point (hot stage microscopy) Permanent record photograph Small sample sizes required Disadvantages Time consuming -high operator fatigue - few particles examined* Very low throughput No information on 3D shape Certain amount of subjectivity associated with sizing -operator bias * Overcome with (semi-)automated image analysis systems Electron Microscopy Advantages Particles are individually examined Visual means to see sub-micron specimens Particle shape can be measured Disadvantages Very expensive Time consuming sample preparation Materials such as emulsions difficult/impossible to prepare Low throughput -Not for routine use 7

Weight distribution Sieving Sieve analysis is performed using a nest or stackof sieves where each lower sieve has a smaller aperture size than that of the sieve above it. Sieves can be referred to either by their aperture size = mesh size = sieve number(bp, PhEur) US: The mesh size is the number of wires per linear inch. 250 µm = No. 60 125 µm = No. 120 Approx. size range : 5µm -~3mm Standard woven wire sieves Electroformed micromesh sieves at the lower end or range (< 20µm) Punch plate sieves at the upper range 8

Sieving may be performed wetordry, by machineor by hand, for a fixed timeor until powder passes through the sieve at a constant low rate Machines: Shaking Vibration Use a jet of air to clear the sieves Ultrasonics(wet sieving) Wet sieving Air-jet sieving 9

Advantages Easy to perform Wide size range Inexpensive Disadvantages Known problems of reproducibility Wear/damage in use or cleaning Irregular/agglomerated particles Rod-like particles : overestimate of under-size Labour intensive 10

British Pharmacopoeia Volume V Appendix XVII A. Particle Size of Powders Particle size classification of powders (Ph. Eur. method 2.9.12, Sieve test) The degree of fineness of a powder may be expressed by reference to sieves that comply with the specifications for non-analytical sieves (2.1.4). Coarse powder: Not less than 95% by mass passes through a number 1400 sieve and not more than 40% by mass passes through a number 355 sieve. Moderately fine powder: Not less than 95% by mass passes through a number 355 sieve and not more than 40% by mass passes through a number 180 sieve. Fine powder: Not less than 95% by mass passes through a number 180 sieve and not more than 40% by mass passes through a number 125 sieve. etc. etc. 11

United States Pharmacopeia General Chapters: <811> POWDER FINENESS Classification of Powders by Fineness d 50 = smallest sieve opening through which 50% or more of the material passes Classification of Powder d 50 Sieve Opening (µm) Very Coarse > 1000 Coarse 355 1000 Moderately Fine 180 355 Fine 125 180 Very Fine 90 125 12

Sedimentation Techniques (>1µm) These methods depend on the fact that the terminal velocity of a particle in a fluid increases with size. Weight distribution Stokes' Law ν = ( ρ ρ ) s f 18η gd 2 sph d sph = x ( ρ ρ ) g t s 18η f ν = terminal velocity of sphere ρ s = particle density ρ f = fluid density d sph = sphere diameter η = fluid viscosity g = acceleration due to gravity Stokes's diameter (d st ) is defined as the diameter of the sphere that would settle at the same rate as the particle 13

The particle size distribution of fine powder can be determined by examining a sedimentingsuspension of the powder. 2 categories: (1) Incremental : changes with time in the concentration or density of the suspension at known depths are determined. (2) Cumulative : the rate at which the powder is settling out of suspension is determined. i.e. the accumulated particles are measured at a fixed level after all particles between it and the fluid's surface have settled. 14

The particle size distribution of fine powder can be determined by examining a sedimenting suspension of the powder (1) The pipette method: e.g. the Andreasen pipette (fixed position pipette) Allow a homogeneous suspension to settle in a cylinder,take samples from the settling suspension at a fixed horizontal level at intervals of time. Each sample will contain a representative sample of the suspension, with the exception of particles greater than a critical size, all of which will have settled below the level of the sampling point. The concentration of solid in a sample taken at time tis determined This concentration expressed as a percentage of the initial concentration gives the percentage (w/w) of particles whose falling velocities are equal to or less than x/t. Substitution in the equation above gives the corresponding Stokes' diameter. (2) Photosedimentation technique (Photoextinction sedimentometers) : white light 15

Advantages Equipment required can be relatively simple and inexpensive. Can measure a wide range of sizes with accuracy and reproducibility. Disadvantages Sedimentation analyses must be carried out at concentrations which are sufficiently low for interactive effects between particles to be negligible so that their terminal falling velocities can be taken as equal to those of isolated particles. Large particles create turbulence, are slowed and are recorded undersize. Careful temperature control is necessary to suppress convection currents. The lower limit of particle size is set by the increasing importance of Brownian motion for progressively smaller particles. Particle re-aggregation during extended measurements. Particles have to be completely insoluble in the suspending liquid. 16

Electrical Sensing Zone Method of particle size distribution determination (Coulter Counter) This instrument measures particle volumewhich can be expressed as d v : the diameter of a sphere that has the same volume as the particle. The number and size of particles suspended in an electrolyte is determined by causing them to pass through an orifice an either side of which is immersed an electrode. The changes in electric impedance (resistance) as particles pass through the orifice generate voltage pulses whose amplitude are proportional to the volumes of the particles. Volume distribution 17

Advantages True volume distribution High resolution Wide range of measurement: particle diameter from approx. 0.5-400µm Disadvantages Needs calibration Medium must be an electrolyte* Low particle concentration Errors with porous particles Orifice blocking troublesome Particles below minimum detectable size go unnoticed Difficult with high density materials * Optical Sensing Zone Method Obscuration of light source relates to particle size Advantage of not requiring medium to be an electrolyte any clear liquid will do 18

Laser Light Scattering Techniques (1) Laser Diffraction Particle Size Analysis (Particle size range 0.02-2000µm/0.01-3500µm) (2) Photon Correlation Spectroscopy (Particle size range : 1nm to 5µm) 19

Laser Diffraction Particles pass through a laser beam and the light scattered by them is collected over a range of angles in the forward direction. The angles of diffraction are, in the simplest case inversely related to the particle size. Volume distribution 20

The particles pass through an expanded and collimated laser beam in front of a lens in whose focal plane is positioned a photosensitive detector consisting of a series of concentric rings. Distribution of scattered intensity is analysed by computer to yield the particle size distribution. 21

Advantages: Non-intrusive : uses a low power laser beam Fast : typically <3minutes to take a measurement and analyse. Precise and wide range up to 64 size bands can be displayed covering a range of up to 100,000:1 in size. Absolute measurement: No calibration is required, the instrument is based on fundamental physical properties. Simple to use Highly versatile Suspension Material Gas Liquid Solid Gas Fuel sprays Paints Aerosols Inhalers Powders not liquid dispersible. Pneumatic transport soluble powders Liquid Bubbles Emulsions 2 phase fluids Powders easily liquid dispersed. Cohesive powders. Solid Reference standards (reticules) 22

Disadvantages: expense volume measurement all other outputs are numerical transformations of this basic output form, assuming spherical particles must be a difference in refractive indices between particles and suspending medium 23

PCS Large particles move more slowly than small particles, so that the rate of fluctuation of the light scattered from them is also slower. PCS uses the rate of change of these light fluctuations to determine the size distribution of the particles scattering light. 24

25

Comparison of a "snap-shot" of each speckle pattern with another taken at a very short time later (microseconds). The time dependent change in position of the speckles relates to the change of position of the particles and hence particle size. The dynamic light signal is sampled and correlated with itself at different time intervals using a digital correlator and associated computer software. The relationship of the auto-correlation function obtained to time intervals is processed to provide estimates of the particle size distribution. 26

Advantages: Non-intrusive Fast Nanometre size range Disadvantages: Sample prep critical Vibration, temperature fluctuations can interfere with analysis Restricted to solid in liquid or liquid in liquid samples Expense Need to know R.I. values and viscosity 27

Methods of presentation and interpretation of particle size analysis data Equivalent sphere diameters 28

Particle size distribution 29

Different types of analysis give different types of distributions! Particle size (microns) Actual number of particles (n) Percentage by number Volume of particles (V=4/3πr 3 ) Total volume of particles of each size (nv) Percentage by volume 2 2000 50.92 4 8000 0.06 4 1000 25.46 34 34000 0.3 8 500 12.73 268 134000 1.0 16 250 6.36 2145 5326250 4.1 32 125 3.18 17157 2144625 15.6 64 50 1.27 137259 6862950 52.7 128 3 0.08 1098069 3294207 25.3 n=3928 nv=13014032 30