<788> PARTICULATE MATTER IN INJECTIONS
|
|
|
- Helen Snow
- 9 years ago
- Views:
Transcription
1 <788> PARTICULATE MATTER IN INJECTIONS Particulate matter in injections and parenteral infusions consists of mobile undissolved particles, other than gas bubbles, unintentionally present in the solutions. For the determination of particulate matter, two procedures, Method 1 (Light Obscuration Particle Count Test) and Method 2 (Microscopic Particle Count Test), are specified hereinafter. When examining injections and parenteral infusions for sub-visible particles Method 1 is preferably applied. However, it may be necessary to test some preparations by the light obscuration particle count test followed by the microscopic particle count test to reach a conclusion on conformance to the requirements. Not all parenteral preparations can be examined for sub-visible particles by one or both of these methods. When Method 1 is not applicable, e.g. in case of preparations having reduced clarity or increased viscosity, the test should be carried out according to Method 2. Emulsions, colloids, and liposomal preparations are examples. Similarly, products that produce air or gas bubbles when drawn into the sensor may also require microscopic particle count testing. If the viscosity of the preparation to be tested is sufficiently high so as to preclude its examination by either test method, a quantitative dilution with an appropriate diluent may be made to decrease viscosity, as necessary, to allow the analysis to be performed. The results obtained in examining a discrete unit or group of units for particulate matter cannot be extrapolated with certainty to other units that remain untested. Thus, statistically sound sampling plans must be developed if valid inferences are to be drawn from observed data to characterize the level of particulate matter in a large group of units. METHOD 1. LIGHT OBSCURATION PARTICLE COUNT TEST Use a suitable apparatus based on the principle of light blockage which allows an automatic determination of the size of particles and the number of particles according to
2 size. The definition for particle-free water is provided in Reagent Specifications under Reagents, Indicators and Solution section. The apparatus is calibrated using dispersions of spherical particles of known sizes between 10 µm and 25 µm, USP Particle Count Reference Standard. These standard particles are dispersed in particle-free water. Care must be taken to avoid aggregation of particles during dispersion. General precautions The test is carried out under conditions limiting particulate matter, preferably in a laminar-flow cabinet. Very carefully wash the glassware and filtration equipment used, except for the membrane filters, with a warm detergent solution and rinse with abundant amounts of water to remove all traces of detergent. Immediately before use, rinse the equipment from top to bottom, outside and then inside, with particle-free water. Take care not to introduce air bubbles into the preparation to be examined, especially when fractions of the preparation are being transferred to the container in which the determination is to be carried out. In order to check that the environment is suitable for the test, that the glassware is properly cleaned and that the water to be used is particle-free, the following test is carried out: determine the particulate matter in 5 samples of particle-free water, each of 5 ml, according to the method described below. If the number of particles of 10 µm or greater size exceeds 25 for the combined 25 ml, the precautions taken for the test are not sufficient. The preparatory steps must be repeated until the environment, glassware and water are suitable for the test. Method Mix the contents of the sample by slowly inverting the container 20 times successively. If necessary, cautiously remove the sealing closure. Clean the outer surfaces of the container opening using a jet of particle-free water and remove the closure, avoiding any
3 contamination of the contents. Eliminate gas bubbles by appropriate measures such as allowing to stand for 2 min or sonicating. For large-volume parenterals, single units are tested. For small-volume parenterals less than 25 ml in volume, the contents of 10 or more units is combined in a cleaned container to obtain a volume of not less than 25 ml; the test solution may be prepared by mixing the contents of a suitable number of vials and diluting to 25 ml with particle-free water or with an appropriate particle-free solvent when particle-free water is not suitable. Small-volume parenterals having a volume of 25 ml or more may be tested individually. Powders for parenteral use are reconstituted with particle-free water or with an appropriate particle-free solvent when particle-free water is not suitable. The number of test specimens must be adequate to provide a statistically sound assessment. For large-volume parenterals or for small-volume parenterals having a volume of 25 ml or more, fewer than 10 units may be tested, based on an appropriate sampling plan. Remove four portions, each of not less than 5 ml, and count the number of particles equal to or greater than 10 µm and 25 µm. Disregard the result obtained for the first portion, and calculate the mean number of particles for the preparation to be examined. Evaluation For preparations supplied in containers with a nominal volume of more than 100 ml, apply the criteria of test 1.A. For preparations supplied in containers with a nominal volume of less than 100 ml, apply the criteria of test 1.B. For preparations supplied in containers with a nominal volume of 100 ml, apply the criteria of test 1.B. If the average number of particles exceeds the limits, test the preparation by the Microscopic Particle Count Test.
4 Test 1.A Solutions for parenteral infusion or solutions for injection supplied in containers with a nominal content of more than 100 ml. The preparation complies with the test if the average number of particles present in the units tested does not exceed 25 per ml equal to or greater than 10 µm and does not exceed 3 per ml equal to or greater than 25 µm. Test 1.B Solutions for parenteral infusion or solutions for injection supplied in containers with a nominal content of less than 100 ml. The preparation complies with the test if the average number of particles present in the units tested does not exceed 6000 per container equal to or greater than 10 µm and does not exceed 600 per container equal to or greater than 25 µm. METHOD 2. MICROSCOPIC PARTICLE COUNT TEST Use a suitable binocular microscope, filter assembly for retaining particulate matter and membrane filter for examination. The microscope is equipped with an ocular micrometer calibrated with an objective micrometer, a mechanical stage capable of holding and traversing the entire filtration area of the membrane filter, two suitable illuminators to provide episcopic illumination in addition to oblique illumination, and is adjusted to 100 ± 10 magnifications. The ocular micrometer is a circular diameter graticule (see Figure 1) and consists of a large circle divided by crosshairs into quadrants, transparent and black reference circles 10 µm and 25 µm in diameter at 100 magnifications, and a linear scale graduated in 10 µm increments. It is calibrated using a stage micrometer that is certified by either a domestic or international standard institution. A relative error of the linear scale of the graticule within ± 2 per cent is acceptable. The large circle is designated the graticule field of view (GFOV). Two illuminators are required. One is an episcopic brightfield illuminator internal to the microscope, the other is an external, focusable auxiliary illuminator adjustable to give reflected oblique illumination at an angle of 10 to 20.
5 The filter assembly for retaining particulate matter consists of a filter holder made of glass or other suitable material, and is equipped with a vacuum source and a suitable membrane filter. The membrane filter is of suitable size, black or dark gray in color, non-gridded or gridded, and 1.0 µm or finer in nominal pore size. General precautions The test is carried out under conditions limiting particulate matter, preferably in a laminar-flow cabinet. Very carefully wash the glassware and filter assembly used, except for the membrane filter, with a warm detergent solution and rinse with abundant amounts of water to remove all traces of detergent. Immediately before use, rinse both sides of the membrane filter and the equipment from top to bottom, outside and then inside, with particle-free water. In order to check that the environment is suitable for the test, that the glassware and the membrane filter are properly cleaned and that the water to be used is particle-free, the following test is carried out: determine the particulate matter of a 50 ml volume of particle-free water according to the method described below. If more than 20 particles 10 µm or larger in size or if more than 5 particles 25 µm or larger in size are present within the filtration area, the precautions taken for the test are not sufficient. The preparatory steps must be repeated until the environment, glassware, membrane filter and water are suitable for the test. Method Mix the contents of the samples by slowly inverting the container 20 times successively. If necessary, cautiously remove the sealing closure. Clean the outer surfaces of the container opening using a jet of particle-free water and remove the closure, avoiding any contamination of the contents. For large-volume parenterals, single units are tested. For small-volume parenterals less
6 than 25 ml in volume, the contents of 10 or more units is combined in a cleaned container; where justified and authorized, the test solution may be prepared by mixing the contents of a suitable number of vials and diluting to 25 ml with particle-free water or with an appropriate particle-free solvent when particle-free water is not suitable. Smallvolume parenterals having a volume of 25 ml or more may be tested individually. Powders for parenteral use are constituted with particle-free water or with an appropriate particle-free solvent when particle-free water is not suitable. The number of test specimens must be adequate to provide a statistically sound assessment. For large-volume parenterals or for small-volume parenterals having a volume of 25 ml or more, fewer than 10 units may be tested, based on an appropriate sampling plan. Wet the inside of the filter holder fitted with the membrane filter with several milliliters of particle-free water. Transfer to the filtration funnel the total volume of a solution pool or of a single unit, and apply vacuum. If needed add stepwise a portion of the solution until the entire volume is filtered. After the last addition of solution, begin rinsing the inner walls of the filter holder by using a jet of particle-free water. Maintain the vacuum until the surface of the membrane filter is free from liquid. Place the membrane filter in a Petri dish and allow the membrane filter to air-dry with the cover slightly ajar. After the membrane filter has been dried, place the Petri dish on the stage of the microscope, scan the entire membrane filter under the reflected light from the illuminating device, and count the number of particles that are equal to or greater than 10 µm and the number of particles that are equal to or greater than 25 µm. Alternatively, partial membrane filter count and determination of the total membrane filter count by calculation is allowed. Calculate the mean number of particles for the preparation to be examined. The particle sizing process with the use of the circular diameter graticule is carried out by estimating the equivalent diameter of the particle in comparison with the 10 and 25 um reference circles on the graticule. Thereby the particles are not moved from their initial locations within the graticule field of view and are not superimposed on the reference circles for comparison. The inner diameter of the transparent graticule reference circles is
7 used to size white and transparent particles, while dark particles are sized by using the outer diameter of the black opaque graticule reference circles. In performing the microscopic particle count test do not attempt to size or enumerate amorphous, semi-liquid, or otherwise morphologically indistinct materials that have the appearance of a stain or discoloration on the membrane filter. These materials show little or no surface relief and present a gelatinous or film-like appearance. In such cases the interpretation of enumeration may be aided by testing a sample of the solution by the light obscuration particle count test. Evaluation For preparations supplied in containers with a nominal volume of more than 100 ml, apply the criteria of test 2.A. For preparations supplied in containers with a nominal volume of less than 100 ml, apply the criteria of test 2.B. For preparations supplied in containers with a nominal volume of 100 ml, apply the criteria of test 2.B. Test 2.A Solutions for parenteral infusion or solutions for injection supplied in containers with a nominal content of more than 100 ml. The preparation complies with the test if the average number of particles present in the units tested does not exceed 12 per ml equal to or greater than 10 µm and does not exceed 2 per ml equal to or greater than 25 µm. Test 2.B Solutions for parenteral infusion or solutions for injection supplied in containers with a nominal content of less than 100 ml The preparation complies with the test if the average number of particles present in the units tested does not exceed 3000 per container equal to or greater than 10 µm and does not exceed 300 per container equal to or greater than 25 µm.
8
LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008
LIFE SCIENCE I TECHNICAL BULLETIN ISSUE N 11 /JULY 2008 PARTICLE CHARACTERISATION IN EXCIPIENTS, DRUG PRODUCTS AND DRUG SUBSTANCES AUTHOR: HILDEGARD BRÜMMER, PhD, CUSTOMER SERVICE MANAGER, SGS LIFE SCIENCE
COMMON LABORATORY APPARATUS
COMMON LABORATORY APPARATUS Beakers are useful as a reaction container or to hold liquid or solid samples. They are also used to catch liquids from titrations and filtrates from filtering operations. Bunsen
Care and Use of the Compound Microscope
Revised Fall 2011 Care and Use of the Compound Microscope Objectives After completing this lab students should be able to 1. properly clean and carry a compound and dissecting microscope. 2. focus a specimen
Technical Considerations Detecting Transparent Materials in Particle Analysis. Michael Horgan
Technical Considerations Detecting Transparent Materials in Particle Analysis Michael Horgan Who We Are Fluid Imaging Technology Manufacturers of the FlowCam series of particle analyzers FlowCam HQ location
Related topics: Application Note 27 Data Analysis of Tube Formation Assays.
Tube Formation Assays in µ-slide Angiogenesis Related topics: Application Note 27 Data Analysis of Tube Formation Assays. Contents 1. General Information... 1 2. Material... 2 3. Work Flow Overview...
ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners
ISO 21501 A Standard Methodology to Optical Particle Counter Calibration and What It Means to Cleanroom Owners Tony Harrison and Bob Latimer ISO 21501- A Standard Methodology to Optical Particle Counter
EXTRACTION OF DNA FROM CALF THYMUS CELLS Revised 2/1/96 Introduction
Revised 2/1/96 Introduction Cells may be classified into two primary types depending on whether they have a discrete nucleus (eukaryotic) or do not (prokaryotic). Prokaryotes include bacteria, such as
The Influence of Carbon Dioxide on Algae Growth
The Influence of Carbon Dioxide on Algae Growth The first objective of this experiment is to show that increased atmospheric concentrations of carbon dioxide, CO 2, can stimulate algae growth. The second
BRIEFING 661.2 Plastic Packaging Systems for Pharmaceutical Use.
BRIEFING 661.2 Plastic Packaging Systems for Pharmaceutical Use. USP proposes the revision and development of a suite of plastic packaging system standards in the current issue of PF. General test chapter
Method 202 Dry Impinger Method for Determining Condensable Particulate Emissions from Stationary Sources. By: Paul Ottenstein
Air Quality Issues in the Rocky Mountain Region PM2.5 Source Testing Method 201A Determination PM 10 and PM 2.5 Emissions from Stationary Sources (Constant Sampling Rate Procedure) Method 202 Dry Impinger
PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE
Test Procedure for PARTICLE SIZE ANALYSIS OF SOILS TxDOT Designation: Tex-110-E Effective Date: August 1999 1. SCOPE 1.1 This method covers the quantitative determination of the distribution of particle
MICROSCOPY. To demonstrate skill in the proper utilization of a light microscope.
MICROSCOPY I. OBJECTIVES To demonstrate skill in the proper utilization of a light microscope. To demonstrate skill in the use of ocular and stage micrometers for measurements of cell size. To recognize
Tamsulosin Hydrochloride Capsules
. nal Revision Bulletin Official October 1, 2011 Tamsulosin 1 standard solution, and shake well. Centrifuge at 1500 rpm for 10 min, and use the supernatant, passing it if Tamsulosin Hydrochloride Capsules
POWDER PROPERTIES LABORATORY
Ground Rules POWDER PROPERTIES LABORATORY You will work as a team of no more than 6 students. At the end of this laboratory session each team will turn in a single report. The report will be reviewed,
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY
CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY 9.1 POLICY This test method may be used to confirm the presence of zolpidem (ZOL), with diazepam-d 5 (DZP-d 5 ) internal standard, in
Apr 17, 2000 LAB MANUAL 1302.0. 1302 PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)
Apr 17, 2000 LAB MANUAL 1302.0 1302 PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified) 1302.1 SCOPE This method describes a procedure for the quantitative determination of the distribution
Shampoo Properties Evaluation General Science
/ 10 Shampoo Properties Evaluation General Science Name It is difficult to obtain exact information on the formulation of commercial shampoos. These facts are held by the manufacturer to protect their
Determination of a Chemical Formula
1 Determination of a Chemical Formula Introduction Molar Ratios Elements combine in fixed ratios to form compounds. For example, consider the compound TiCl 4 (titanium chloride). Each molecule of TiCl
Promoting safer use of injectable medicines
Promoting safer use of injectable medicines A template standard operating procedure for: prescribing, preparing and administering injectable medicines in clinical areas Introduction The use of injectable
105 Adopted: 27.07.95
105 Adopted: 27.07.95 OECD GUIDELINE FOR THE TESTING OF CHEMICALS Adopted by the Council on 27 th July 1995 Water Solubility INTRODUCTION 1. This guideline is a revised version of the original Guideline
DryWeight BulkVolume
Test Procedure for BULK SPECIFIC GRAVITY AND WATER ABSORPTION OF AGGREGATE TxDOT Designation: Tex-201-F Effective Date: January 2016 1. SCOPE 1.1 Use this method to determine the bulk specific gravity
Sterilization methods and equipment Lab 1-2
Sterilization methods and equipment Lab 1-2 PHT 434 Sterilization Sterilization a process that by which all viable M.O are removed or destroyed, based on a probability function. Sterilization concept Sterilization
Calibration of Volumetric Glassware
CHEM 311L Quantitative Analysis Laboratory Revision 2.3 Calibration of Volumetric Glassware In this laboratory exercise, we will calibrate the three types of glassware typically used by an analytical chemist;
How To Count Asbestos
Appendix B NOA Concentrations in Road Surfacing Material, Slodusty Road, Garden Valley, California Introduction As part of a study to identify potential sources of naturally occurring asbestos (NOA) releases
Calibration of Volumetric Glassware
Chemistry 119: Experiment 2 Calibration of Volumetric Glassware For making accurate measurements in analytical procedures, next in importance to the balance is volumetric equipment. In this section volumetric
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
PREPARATION FOR CHEMISTRY LAB: COMBUSTION
1 Name: Lab Instructor: PREPARATION FOR CHEMISTRY LAB: COMBUSTION 1. What is a hydrocarbon? 2. What products form in the complete combustion of a hydrocarbon? 3. Combustion is an exothermic reaction. What
Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater
Document: AND Sol Env 08 2013 Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater Matrix specific sample preparation and testing methods for environmental waters
S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia
March 2012 S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS Final text for addition to The International Pharmacopoeia This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications
Exercise 2. The Compound Light Microscope
6 Exercise 2 The Compound Light Microscope INTRODUCTION: Student Learning Objectives: After completing this exercise students will: a. Demonstrate proficient use of the microscope using low, high dry,
Good practice for the preparation of injectable medicines in clinical areas
Further reading Dougherty L and Lister S (Eds). The Royal Marsden Hospital Manual of Clinical Nursing Procedures (th edition), Blackwell Publishing, Oxford, 00. NMC standards for medicines management (008).
Pure Solid Compounds: Molecules held together in rigid formations by intermolecular forces.
Recrystallization: Purification of Solid Compounds Pure Solid Compounds: Molecules held together in rigid formations by intermolecular forces. Types of Intermolecular Forces? 1. Van der Waal s forces London
Hands-On Labs SM-1 Lab Manual
EXPERIMENT 4: Separation of a Mixture of Solids Read the entire experiment and organize time, materials, and work space before beginning. Remember to review the safety sections and wear goggles when appropriate.
ISOLATION AND PROPERTIES OF SECRETORY GRANULES FROM RAT ISLETS OF LANGERHANS. II. Ultrastructure of the Beta Granule
ISOLATION AND PROPERTIES OF SECRETORY GRANULES FROM RAT ISLETS OF LANGERHANS II Ultrastructure of the Beta Granule MARIE H GREIDER, S L HOWELL, and P E LACY From the Department of Pathology, Washington
Test Methods for the Colour Fastness of Leather & Dyes. TFL Leather Technology Ltd. Quality and Environment February 2004 Version 1.
Test s for the Colour Fastness of Leather & Dyes TFL Leather Technology Ltd. Quality and Environment February 2004 Version 1.0 Contents Colour Fastness of Dyed Leather 1. Grey scale for assessing change
BRIEFING 7 LABELING DEFINITION
Page 1 of 10 BRIEFING 7 Labeling. This general chapter provides definitions and standards for labeling of official articles. Note that, as with compendial quality standards, labeling requirements also
Microbiological Testing of the Sawyer Mini Filter. 16 December 2013. Summary
Microbiological Testing of the Sawyer Mini Filter 16 December 2013 Summary The Sawyer Mini Filter was tested for its ability to remove three microorganisms Raoultella terrigena, Bacillus subtilis, and
SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES FOP FOR AASHTO T 27 (11)
SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES FOP FOR AASHTO T 27 (11) MATERIALS FINER THAN 75 µm (No. 200) SIEVE IN MINERAL AGGREGATE BY WASHING FOP FOR AASHTO T 11 (11) Scope Sieve analysis determines
Determination of Insoluble Solids in Pretreated Biomass March 2008 Material
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Determination of Insoluble Solids
EXPERIMENT #1: MICROSCOPY
EXPERIMENT #1: MICROSCOPY Brightfield Compound Light Microscope The light microscope is an important tool in the study of microorganisms. The compound light microscope uses visible light to directly illuminate
Welcome to chapter 10. The following chapter is called Equipment maintenance and monitoring. The author is Ronny Janssens.
Welcome to chapter 10. The following chapter is called Equipment maintenance and monitoring. The author is Ronny Janssens. 1 After finishing this chapter, the student should be familiar with - the requirements
ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual
ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual Catalog numbers 780-1070 780-1650 Please read these instructions before you use ENrich SEC high-resolution size exclusion
Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm
Quick guide: using CTE security straws for cryopreservation of pronuclear stages, embryos and sperm 1. How to prepare straws for pronuclear stages and embryos (use straws with plug, 66.5 mm) Straws are
Reconstitution of Solutions
Chapter 12 Reconstitution of Solutions Reconstitution Process of mixing and diluting solutions Some medications supplied in powder form and must be mixed with liquid before administration Parts of Solutions
Mixtures and Pure Substances
Unit 2 Mixtures and Pure Substances Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances. They
How To Use An Asbestos Microscope
Asbestos Microscopes and Accessories Pyser-SGI has been supplying microscopes and accessories into Asbestos Laboratories for over 40 years PS12 Stage Micrometer with UKAS Certificate of Calibration - For
INSTRUCTIONS 56-1190-98. Edition AC
Sephacryl S-100 High Resolution Sephacryl S-200 High Resolution Sephacryl S-300 High Resolution Sephacryl S-400 High Resolution Sephacryl S-500 High Resolution INSTRUCTIONS Sephacryl High Resolution chromatography
Odor (Threshold Odor, Consistent Series)
METHOD #: 140.1 (Issued 1971) TITLE: ANALYTE: INSTRUMENTATION: Odor (Threshold Odor, Consistent Series) Odor N/A STORET No. 60 C: 00086 Room Temp: 00085 1.0 Scope and Application 1.1 This method is applicable
Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2
Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: [email protected] ELISA Kit for Human Prostaglandin E1(PG-E1) Instruction manual Cat. No.: E0904Hu
Solids, Volatile Dissolved and Fixed Dissolved
, 8277 Solids, Volatile Dissolved and Fixed Dissolved Gravimetric Method 1 Scope and Application: For wastewater. 1 Adapted from Standard Methods for the Examination of Water and Wastewater DOC316.53.001206
SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER
Chemistry 111 Lab: Synthesis of a Copper Complex Page H-1 SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER In this experiment you will synthesize a compound by adding NH 3 to a concentrated
AURAMINE O STAIN. Preanalytical Considerations
AURAMINE O STAIN Preanalytical Considerations I. PRINCIPLE Acid-fast mycobacteria resist decolorization by acid-alcohol after primary staining owing to the high lipid (mycolic acid) content in their cell
Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate
Cantaurus, Vol. 7, 5-8, May 1999 McPherson College Division of Science and Technology Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate Janet Bowen ABSTRACT Sulfate is used in
WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots. Fluorescent detection via: Goat anti-mouse SureLight P3
WESTERN BLOT DETECTION KIT Buffers and detection reagents for up to ten 10 x 10 cm 2 blots Fluorescent detection via: Goat anti-mouse SureLight P3 Cat. #: WK-P112 6440 Dobbin Road, Suite D Phone (443)
Separation by Solvent Extraction
Experiment 3 Separation by Solvent Extraction Objectives To separate a mixture consisting of a carboxylic acid and a neutral compound by using solvent extraction techniques. Introduction Frequently, organic
In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..
Identification of a Substance by Physical Properties 2009 by David A. Katz. All rights reserved. Permission for academic use provided the original copyright is included Every substance has a unique set
METHOD A7 THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF GRAVEL, SOIL AND SAND
SCOPE METHOD A7 THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF GRAVEL, SOIL AND SAND Definition The maximum dry density and optimum moisture content, as defined below, is
Cat S O SSM. Services. Reporting Particle Count by ISO Code. Management Guide. Two methods of reading particles
Cat S O SSM Services Management Guide Two methods of reading particles Measuring contamination ISO Codes ISO 11171:1999 Reporting Particle Count by ISO Code Introduction... 3 What ISO Means... 3 Two Methods
Surface Tension Measurements Using the Drop Shape Method
Surface Tension Measurements Using the Drop Shape Method By Roger P. Woodward, Ph.D. First Ten Angstroms, 465 Dinwiddie Street, Portsmouth, VA 23704 Tel: 1.757.393.1584 Fax: 1.757.393.3708 email: [email protected]
Experiment 12- Classification of Matter Experiment
Experiment 12- Classification of Matter Experiment Matter can be classified into two groups: mixtures and pure substances. Mixtures are the most common form of matter and consist of mixtures of pure substances.
3.4 TEST FOR BACTERIAL ENDOTOXINS. Final text for revision of The International Pharmacopoeia
Document QAS/11.5 FINAL July 01 3. TEST FOR BACTERIAL ENDOTOXINS Final text for revision of The International Pharmacopoeia This monograph was adopted at the Forty-sixth WHO Expert Committee on Specifications
An In-Gel Digestion Protocol
An In-Gel Digestion Protocol This protocol describes the digestion of a protein present in an SDS-PAGE gel band with trypsin. The band can be taken from either a 1D or 2D electrophoresis gel. Reagents
Urinalysis and Body Fluids CRg
Urinalysis and Body Fluids CRg Unit 2; Session 1 Urine Microscopic Examination The Complete Urinalysis Physical properties already covered Chemical analysis in the next unit Microscopic our current focus
Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:
Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Your Name: Date: Partner(s) Names: Objectives: React magnesium metal with hydrochloric acid, collecting the hydrogen over water. Calculate the grams
Aptima Specimen Transfer Kit
Aptima Specimen Transfer Kit For Use with ThinPrep and SurePath Liquid Cytology Specimens Intended Use For in vitro diagnostic use. For US export only. The Aptima Specimen Transfer kit is only for use
MANUAL PLATELET COUNT
MANUAL PLATELET COUNT LAB OBJECTIVE The student will be able to perform, within K20% accuracy as compared to the automated result, five manual platelet counts using the Unopette system. and the light microscope.
CHITOSAN FILM PREPARATION Instructions for laboratory experiments. Tuija Annala 29.11.2007 Rev 0
CHITOSAN FILM PREPARATION Instructions for laboratory experiments Tuija Annala 29.11.2007 Rev 0 Table of Contents 1 Introduction...3 2 Equipment and materials...3 3 Recipe...4 2 (6) 1 INTRODUCTION Chitosan
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit
Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit Catalog No: E0479r 96 Tests Operating instructions www.eiaab.com FOR RESEARCH USE ONLY; NOT FOR THERAPEUTIC OR DIAGNOSTIC APPLICATIONS! PLEASE READ THROUGH
CHEM 2423 Recrystallization of Benzoic Acid EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid
EXPERIMENT 4 - Purification - Recrystallization of Benzoic acid Purpose: a) To purify samples of organic compounds that are solids at room temperature b) To dissociate the impure sample in the minimum
Particle Measurement Technology in Practice. From Theory to Application.
Particle Measurement Technology in Practice. From Theory to Application. Page 3 1 Introduction to Particle Counting Page 19 2.4.2 General Installation Recommendations Page 3 Page 3 1.1 Physics Fundamentals
MANUAL PLATELET COUNT
MANUAL PLATELET COUNT Principle Whole blood is diluted with a 1% ammonium oxalate solution. The isotonic balance of the diluent is such that all erythrocytes are lysed while the leukocytes, platelets,
B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS
TECHNICAL INFORMATION B&W PAPER DEVELOPERS DEVELOPERS FOR THE DISH/TRAY PROCESSING OF BLACK AND WHITE PHOTOGRAPHIC PAPERS ILFORD MULTIGRADE developer MULTIGRADE is a rapid liquid concentrate dimezone-s/hydroquinone
ASBESTOS, CHRYSOTILE by XRD 9000
ASBESTOS, CHRYSOTILE by XRD 9000 Mg 3 Si 2 O 5 (OH) 4 MW: ca. 283 CAS: 12001-29-5 RTECS: CI6478500 METHOD: 9000, Issue 2 EVALUATION: FULL Issue 1: 15 May 1989 Issue 2: 15 August 1994 EPA Standard (Bulk):
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research J. Jones, J. Denbigh, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 20581 Key Words SPE, SOLA,
SODIUM CARBOXYMETHYL CELLULOSE
SODIUM CARBOXYMETHYL CELLULOSE Prepared at the 28th JECFA (1984), published in FNP 31/2 (1984) and in FNP 52 (1992). Metals and arsenic specifications revised at the 55 th JECFA (2000). An ADI not specified
Microscopes and the Metric System
Microscopes and the Metric System BIO162 Fall 2007 Sizes of Microorganisms: -Viruses: 0.01 0.3 um -Bacteria: 1 3 um -Fungi: 3 30 um -Protozoa: 5 1000 um 1 Measuring Microorganisms Ocular Micrometer The
Physical & Chemical Properties. Properties
Physical & Chemical Properties Properties Carbon black can be broadly defined as very fine particulate aggregates of carbon possessing an amorphous quasi-graphitic molecular structure. The most significant
CHAPTER 3 OBSERVING MICROORGANISMS THROUGH A MICROSCOPE. I. UNITS OF MEASUREMENT - See Table 3.1 in text. + Fig. 3.2
CHAPTER 3 OBSERVING MICROORGANISMS THROUGH A MICROSCOPE I. UNITS OF MEASUREMENT - See Table 3.1 in text. + Fig. 3.2 II. MICROSCOPY: THE INSTRUMENTS A. COMPOUND LIGHT MICROSCOPY Figure 3.3 1. Have ocular
The Basic Principles of Sieve Analysis
The Basic Principles of Sieve Analysis Introduction Many natural and manufactured materials occur in a disperse form, which means that they consist of differently shaped and sized particles. The particle
(a) Method 1 Sample and velocity traverses for stationary sources.
While we have taken steps to ensure the accuracy of this Internet version of the document, it is not the official version. Please refer to the official version in the FR publication, which appears on the
Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.
K-ASSAY Mouse IgM ELISA For the quantitative determination of IgM in mouse biological samples Cat. No. KT-407 For Research Use Only. 1 Rev. 072309 K-ASSAY PRODUCT INFORMATION Mouse IgM ELISA Cat. No. KT-407
Uscn Life Science Inc. Wuhan
Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: [email protected] ELISA Kit for Human Creatine Kinase,Mitochondrial 1A (CKMT1A) Instruction manual
A Comparative Study of In-Process and Finished Products Quality Control Tests for Ophthalmic Products in Different Pharmacopoeias
A Comparative Study of In-Process and Finished Products Quality Control Tests for Ophthalmic Products in Different Pharmacopoeias N. Srujana, Pooja M. Balachandra*, M.P. Venkatesh, Balamuralidhara V, T.M.
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light
AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light Name: Period: Date: MULTIPLE CHOICE. Choose the one alternative that best completes the statement or answers the question. 1) Reflection,
Molar Mass of Polyvinyl Alcohol by Viscosity
Molar Mass of Polyvinyl Alcohol by Viscosity Introduction Polyvinyl Alcohol (PVOH) is a linear polymer (i. e., it has little branching) of Ethanol monomer units: -CH 2 -CHOH- Unlike most high molar mass
Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use
GE Healthcare Instructions 28-9226-84 AD ReadyToProcess Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use 1 Introduction... 1 2 Inspect the Cartridge... 1 3 General Description... 2 4
Particle size measurement of lactose for dry powder inhalers
Particle size measurement of lactose for dry powder inhalers MCC Starch Lactose Inhalation Superdisintegrants 1 Introduction The particle size of lactose has been shown to be important for dry powder
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
CHAPTER 2: LIQUID VISCOSITY MEASUREMENT
CHAPTER 2: LIQUID VISCOSITY MEASUREMENT Objective Calculate viscosity (dynamic or absolute, and kinematic) and determine how this property varies with changes in temperature for a constant-composition
Western Blotting For Protein Analysis
Western Blotting For Protein Analysis Part 1: Laemmli Gel Electrophoresis Using Mini-PROTEAN II Electrophoresis Cell Note: Powder-free gloves should be worn throughout the entire procedure. A. Preparing
Dissolved and precipitated oxalate
Accepted 2005 Process liquors from bleach plants Dissolved and precipitated oxalate Using Ion Chromatography 0 Introduction In bleach plants of pulp mills with a high degree of system closure, there is
Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment
(Jan 2005) (Corr.1 Nov 2005) (Rev.1 Oct 2006) (Corr.1 Oct 2007) (Rev.2 Feb 2015) Type Testing Procedure for Crankcase Oil Mist Detection and Alarm Equipment 1. Scope 1.1 To specify the tests required to
Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material
Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace
HEPA FILTER DEFECTS ARE COMMON
HEPA FILTER DEFECTS ARE COMMON Kenneth F. Cherry 1 and Kenneth A. Smigielski 2 1 NCEC Inc. 2 First Solar LLC. ABSTRACT HEPA filters (High Efficiency Particulate Air) filters are claimed by vendors to have
8.0. The most complete image analysis solution CLEMEX VISION PE. Intelligent systems designed for multiple or complex applications
The most complete image analysis solution CLEMEX VISION PE Intelligent systems designed for multiple or complex applications Customized to meet your needs Difficult applications made simple Our staff's
ReadyPrep Protein Extraction Kit (Soluble/Insoluble) Instruction Manual. Catalog #163-2085
ReadyPrep Protein Extraction Kit (Soluble/Insoluble) Instruction Manual Catalog #163-2085 For technical service, call your local Bio-Rad office, or in the US, call 1-800-4BIORAD (1-800-424-6723) Table
Coliforms: Membrane Filtration (simultaneous detection), continued
EPA Approved* Method 10029 Coliforms: Membrane Filtration (simultaneous detection) For detection of: total coliforms, E. coli Media: m-coliblue24 Broth Sample Type: potable water, nonpotable water, wastewater
Instructions for Use. Components of the GENOTROPIN PEN 12
Instructions for Use Important Note Please read these instructions completely before using the GENOTROPIN PEN 12. If there is anything you do not understand or cannot do, call the toll-free number listed