SUPERIOR FIRE RESISTANCE



Similar documents
Owner s Guide to Understanding Checks in Glued Laminated Timber

Building Code Clarifications - 7. Fire Resistance

CHAPTER 6 CONSTRUCTION TYPES

Fire-Retardant-Treated (FRT) Plywood

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Wood use in Type I and II (noncombustible) construction

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Building Construction. Lightweight construction. Conventional Construction

FIRE AND SMOKE PROTECTION FEATURES

FIRE AND SMOKE PROTECTION FEATURES

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

M E M O R A N D U M. To: Partnership for Safer Buildings Date: 21 March 2003

St. John s University

FIRE-RESISTANCE-RATED CONSTRUCTION

Excerpts from the Canadian National Building Code (NBC)

Fire-Rated Glass and Glazing START

Fire safety in timber buildings

Fire Testing of Recycled Materials for Building Applications

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

FIRE-RESISTANCE-RATED CONSTRUCTION

Certification: Building Plans Examiner. Exam ID: B3

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Fiberglas, Exterior Wall Thermal Insulation

Glulam Appearance Classifications for Construction Applications

Flame Spread Performance of Wood Products

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Formwork for Concrete

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

2010 edition. Handbook of. Fire-Rated Glass. for schools

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

Design Options (Tradeoffs) Allowed by the 2012 Building Codes for Properties with Sprinkler Systems. April 2013

ISO Types 1-6: Construction Code Descriptions

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

8/18/14. Introduction to. Framing. Terminology and Concepts

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Commercial And Industrial Steel Buildings

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

ATI Evaluation Service A Division of Architectural Testing Certification Services

COMMERCIAL BUILDINGS. Quality Buildings Since 1983

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Continuous Insulation Using Polyiso Wall Sheathing

Designing for Fire Protection

Errata NFPA 1. Fire Code Edition

Structural Failures Cost Lives and Time

Installation Instructions

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

COMMERCIAL BUILDING APPLICATIONS

Wood Projects Outdoors. Post Hole Specifications. Deck Span Tables. Eakes.com

Fire Safety Requirements for Child Care Centre

From Wired Glass to Clear Solutions: Designing with Fire Rated Glass Today

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

PROJECT SUMMARY. Scope of work details: (If phased construction, please see plan submittal guidelines.)

Fire and Concrete Structures

Building Condition Assessment: North Howard Street Baltimore, Maryland

Determining the Right Molding Process for Part Design

Decree of the Ministry of the Environment on fire safety of ventilation systems

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Structural Insulated Panels: Design and Application

Warehouse Checklist. Warehouse Construction

Decree of the Ministry of the Environment. on fire safety of garages

Robert H. White, Research Wood Scientist, U.S. Forest Products Lab., Madison, WI, USA, Brian Kukay, Associate Professor of General

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

The Collapse of Building 7 by Arthur Scheuerman December 8, 06

Guidance on loft conversions in two-storey houses

FINAL FAILURE INVESTIGATION WESTCHESTER NORTH LAGOON BRIDGE. Anchorage, Alaska

Composite Panel Firewall Systems

Home Product Testing

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

Solar Panel Installations

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

H-Stud Area Separation Wall System

FORM DESIGN. easy to work with, and generally available.

Spray Booth Guideline

Residential Decks. Planning and Development Services Department

Overview of Hotel Fire Safety Requirements

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

General Fire Code Requirements Within Commercial Tenant Spaces

Heating Load Calculation

Building Control Guidance Note

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

HOT WORK PERMIT PROGRAM TRAINING. John Braun

FDNY C14 Certificate of Fitness Quiz

Structural fire design Eurocode Timber structures

SECTION 3 ONM & J STRUCTURAL ANALYSIS

The Case for Cross Laminated Timber: Part 2

The replacement or modification of existing windows shall comply with the following requirements:

Ceiling Mounted Folding Attic Ladders Installation Instructions

Safety Storage Cabinets

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Transcription:

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION SUPERIOR FIRE RESISTANCE GLULAM

Glulam Because of its beauty, strength and ease of construction, wood has long been in demand as a building material. Today, structural glued laminated timbers (known as glulam) offer additional reasons to select wood as a structural material. Glulam is fabricated using individual pieces of highstrength, kiln-dried lumber, laminated together under pressure to form large timbers that retain the traditional beauty of wood along with engineered strength, extraordinary fire resistance, thermal efficiency, and dimensional stability. Glulam is typically manufactured using Douglas fir, Hem-Fir, Southern pine, Spruce-Pine-Fir, Alaskan Yellow cedar and Ponderosa pine. These large, laminated timbers can be fabricated in almost any straight or arched configuration for long-span conditions. This allows for the design of large, open spaces with minimal columns. Long-length glulam are appropriate for complete structural systems in many types of buildings including churches, gymnasiums, auditoriums and recreational spaces. Everyday uses in smaller buildings include ridge beams, garage door headers, door and window headers, long-span girders, stair treads and stringers, and heavy timber trusses.

Efficient, Cost-Effective Fire Protection In the United States, the use of glulam is widely accepted as one of the most efficient and least expensive ways to meet the recognized criteria for fire protection as set forth in the U.S. model building codes. Advances in test methods and fire technology have increased our understanding of how glulam responds to fire exposure. This knowledge, in turn, has led to the development of design procedures that further improve fire performance. FIREPROOF VERSUS FIRESAFE Fireproof buildings do not exist. The contents are combustible. As such, it is usually a building s contents and not its structural components, which pose the greatest potential fire hazard to life and property. Fire occurrences in the contents of so-called fireproof buildings can be so severe that a building constructed with noncombustible framing can collapse. The fire in Chicago s McCormick Place exhibition hall is a classic example. All structural members of this large exhibition hall, including interior non-bearing walls, were constructed of non-combustible materials. In 1967, a fire quickly spread through the contents of the hall, generating temperatures so high that steel beams, girders and trusses buckled in the heat and the entire roof collapsed. The building was a total loss at a cost of $150 million. With this lesson and others, the goal has become firesafe design, rather than fireproof. This goal can be achieved with combustible structural materials as long as building code regulations are met. In addition to structural materials, considerations include the combustibility of contents and furnishings, interior finishes, the degree of protection provided by interior sprinklers, and the availability of adequate firefighting equipment. A reliable smoke detector with an alarm system and easily accessible exits are also vital in protecting a building and its occupants. LEFT: Two tiers of glulam arches rise to more than 79 feet at the highest point in the Great Buddha Hall in Carmel, NY. ABOVE: Aftermath of the fire at Turbotech, Inc. in Vancouver, WA. Glulam remained standing while the rest of the so-called fireproof building collapsed.

Guide to Fire Performance PERFORMANCE OF LARGE TIMBERS IN FIRES When exposed to fire, wood retains its strength for a longer period of time than metal. Unprotected metals quickly lose their strength and collapse suddenly, often with little warning. In contrast, wood loses strength slowly and only as material is lost through surface charring. Average building-fire temperatures range from 1290º to 1650º Fahrenheit. Steel weakens dramatically as its temperature climbs above 450ºF, retaining only 10% of its strength at about 1380ºF. As a rule, wood will not ignite until it reaches a temperature of around 480ºF. Once it catches fire, wood typically develops char at the rate of 1 40th inch per minute under an ASTM E-119 fire exposure. The char naturally insulates the wood and raises the temperature level it can withstand. Thus, in a 30-minute fire, only 3 4 of an inch of each exposed surface of the glulam is lost to charring, leaving most of the original cross section intact. CONSTRUCTION APPROACHES Buildings constructed with large structural timbers have excellent fire-resistive qualities. U.S. model building codes recognize these qualities and provide guidelines for fire-resistive, heavy timber construction approaches. Two distinct approaches are included in the codes: Heavy Timber Construction and Fire Resistive Construction. Heavy Timber Construction Heavy timber construction has been recognized by the model building codes for many years. To meet the requirements of Heavy Timber Construction, limitations are placed on the minimum size, including depth and thickness, of all load-carrying wood members. Other requirements include the avoidance of concealed spaces and the use of approved construction details. When properly sized, glulam meets the requirements of Heavy Timber Construction. The performance of heavy timber structures under fire conditions is markedly superior to most unprotected non-combustible construction. Fire fighting is easier and safer due to the elimination of concealed spaces and the inherent structural integrity of large laminated timbers. COMPARATIVE STRENGTH LOSS OF WOOD VERSUS STEEL 100 90 80 70 60 50 40 30 20 10 0 WOOD 50% loss 1020 F STEEL 25% loss @ 30 minutes 90% loss @ 30 minutes 1380 F 0 10 20 30 40 TIME (MINUTES) Results from test sponsored by National Forest Products Association at the Southwest Research Institute ABOVE (top): Steel beams have melted and collapsed over charred timber beam which, despite heavy damage, remains in place. ABOVE (middle): Sixteen-inch, 40 lb/ft steel beam (#W16x40) and 7 x 21 glulam beam following fire testing under full load. Steel beam collapsed after only 30 minutes of exposure while the glulam member remained straight and true, charring on 3 4 on exposed surfaces.

Fire-Resistive Construction Fire resistance is the length of time a structural member can support its load before collapsing. The goal of fireresistive construction is to provide adequate fire resistance for occupants to evacuate the building safely. The standard test for measuring fire resistance is the American Society for Testing and Materials (ASTM) Test Method E-119. Ratings of assemblies (including beams, walls and floors) are determined by test procedures that approximate actual fire conditions. The results of ASTM fire tests for building assemblies, sponsored jointly by the American Forest & Paper Association and the American Institute of Timber Construction (AITC), enable designers to calculate specific fire ratings for glulam members. Calculations are based on a consideration of member size, degree of fire exposure, and loads on the member. Additionally, fire-resistance ratings for glulam beams require lay-up modifications. For example, a simple span glulam beam having a cross section of 6 3 4" x 13 1 2" and exposed to fire on three sides can be sized for a one-hour fire rating. To qualify for this rating, an inner or core lamination is removed from the beam at the time of manufacture and replaced by adding an additional tension lamination to the bottom of the beam as shown in the figure above. For additional information related to calculating a fire rating for heavy timber members, please refer to AITC Technical Note No.7 Calculation of Fire Resistance of Glued Laminated Timbers (www.aitc-glulam.org) and to AF&PA Technical Report 10 Calculating the Fire Resistance of Exposed Wood Members (www.awc.org). ADAPTING STANDARD BEAM LAY-UP TO MEET ONE-HOUR FIRE RESISTANCE STANDARD BEAM LAY-UP Compression lams at top Core lams in center Tension lams at bottom 1-HR RATED BEAM LAY-UP One core lam removed from center One tension lam added to bottom The basic lam lay-up can easily be modified to qualify for 1-hour fire rating by removing one core lam from center of member and adding one additional tension lam to tension face, assuming all requirements are satisfied. ABOVE (middle): Typical glulam beam enveloped in flames during standard ASTM E-119 fire test. ABOVE (bottom): Typical glulam beam following fire testing: the outer surface of the beam has charred while the inner areas remain unburned. The charred outer material acts as an insulator during fire, reducing the rate at which the inner material will burn.

Other Fire-Resistance Considerations FIRE-RETARDANT TREATMENTS AND COATINGS Pressure impregnated, fire-retardant treatments are not recommended for large timber or glulam construction. These treatments do not increase the fire-resistance rating of the large timber or glulam. Fire-retardant chemicals reduce the design properties of the wood. In addition, for engineered wood products, the treatments may not be compatible with the adhesives used. The designer is cautioned to verify the effects of fire-retardant treatments (with the supplier) on the strength and performance of any wood product prior to specifying. Fire-retardant paints and stains can effectively reduce flame spread when properly applied. While typically applied to large expanses of interior wood surfaces such as panel products, they can be applied to timber members when a specific flame-spread rating is required per design regulation. However, it is important to understand these coatings do not increase the fire-resistance rating for large timber or glulam members. SPRINKLER SYSTEMS Automatic sprinkler systems have an excellent record of improving fire safety and reducing losses. Many fire codes require that automatic sprinkler systems be installed in larger commercial buildings, and in some cases, added to existing buildings. Such sprinkler systems may improve the fire-resistance and flame-spread ratings for a building s structural system. As a result, an additional story of height or an increased building area may be permitted (by the codes) for buildings with sprinklers. Sprinkler systems also reduce insurance premiums with the result that a sprinkler system often pays for itself within a matter of years, depending upon the value of the building and its contents. FIRE INSURANCE RATES Most insurance companies recognize the excellent fire resistance of heavy timber construction and adjust their insurance rates accordingly. However, in some cases, insurance premiums for noncombustible construction may be lower than for heavy timber construction. In such instances, the reduced cost of glulam construction generally offsets any additional insurance cost. In addition, the more expensive construction methods required for noncombustible materials increase the cost of financing a project. Increased financing costs generally exceed any potential savings on insurance. Thus, using more expensive construction methods in order to gain lower insurance rates may actually result in increased overall costs. INCREASING ALLOWABLE AREAS FOR HEAVY TIMBER CONSTRUCTION Building codes place height and area limitations on buildings to safeguard building occupants. While wood construction is typically assigned the lowest, basic allowable heights and areas, the model building codes also provide many options for increasing allowable areas. The following suggestions address some of the ways increased allowable areas for wood construction may be obtained: 1. Provide one-hour fire-resistive ratings for structural members and assemblies. 2. Install automatic sprinkler systems. 3. Maintain building separation where possible. 4. Seek unlimited areas, where appropriate for specific building occupancy uses, by providing open spaces around the building combined with the use of automatic sprinklers. 5. Install properly constructed area separation walls with protected openings. RIGHT: Long-span glulam reduce the need for interior columns in the second-floor office space of Green Gables Timber Frame Barn, Lake Geneva, WI.

Quality Control and Inspection AITC provides Quality Marks and Certificates of Conformance to licensed glulam manufacturers. Only AITC-licensed glulam producers are permitted to use these Quality Marks and Certificates to identify products conforming to ANSI/AITC A190.1. AITC s Quality Control and Inspection Program for structural glued laminated timber works to: Standardize production, testing, inspection, identification, and certification of structural glued laminated timber. Improve economies through wider utilization of standards. Ensure the manufacture of reliable products. The Program consists of three basic elements: Licensing of qualified glulam manufacturers whose personnel, procedures and facilities comply with the requirements of the American National Standard for Wood Products Structural Glued Laminated Timber ANSI/AITC A190.1. Continuous maintenance of the qualified manufacturer s quality control system in accordance with ANSI/AITC A190.1. Periodic inspection and verification, by the AITC Inspection Bureau, of the licensed laminator s quality control system, procedures and production.

ABOVE: Glulam are a popular choice for the structural systems in recreational spaces. Boathouse, Princeton University. FRONT COVER: Glulam may be fabricated in variety of configurations to meet specific design requirements. Public Library, Beaverton, OR. FOR ADDITIONAL INFORMATION, PLEASE CONTACT: American Institute of Timber Construction 7012 S. Revere Parkway, Suite 140 Centennial, CO 80112 USA tel: (303) 792.9559 fax: (303) 792.0669 email: info@aitc-glulam.org website: www.aitc-glulam.org 2003 American Institute of Timber Construction AITC-OT-04 / 1-04 / 5,000