DISTRIBUTION TRANSFORMER OVERLOAD PROTECTION TRIPPING CIRCUIT



Similar documents
Permissible ambient temperature Operation Storage, transport

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

Microcontroller for Variable Speed BLDC Fan Control System. T.C. Lun System Engineer, Freescale Semiconductor, Inc.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

How To Choose A Transformer

ABB PSPS Erich Steinmann; Generator control-2013

Sentron Series Circuit Breakers

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Arc Terminator Active Arc-Resistant Switchgear

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

Current Transformers Ratio / Polarity / Types

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Tamura Closed Loop Hall Effect Current Sensors

THE INPUT/OUTPUT SYSTEM. Key Points

INSTRUCTIONS FOR MAGNUM DS TRIP UNIT TESTING USING TEST KIT SYLES 140D481G02R, 140D481G02RR, 140D481G03 AND 140D481G04

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Programming Logic controllers

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Thyristor-controlled power supplies and battery chargers

The Application of Circuit Breakers to Reduce Downtime in Datacentres

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

Residual Current Circuit Breaker

EVALUATION OF FAULT ANALYSIS IN TRANSMISSION LINES USING RELAY SETTINGS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

MECE 102 Mechatronics Engineering Orientation

Android based Alcohol detection system using Bluetooth technology

Electronic overload relay EF19 and EF45

ends of transmission line are used for relay operation [70]. Another type of

Project Plan. Project Plan. May Logging DC Wattmeter. Team Member: Advisor : Ailing Mei. Collin Christy. Andrew Kom. Client: Chongli Cai

Electronic overload relay EF65, EF96 and EF146

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

STEPPER MOTOR SPEED AND POSITION CONTROL

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Application Information Improving Efficiency in Smart Grid Applications With Fully Integrated Current Sensing ICs

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

INSTALLATION & SERVICE MANUAL. Display Panel

International Journal of Advancements in Research & Technology, Volume 3, Issue 5, May ISSN THROUGH MOBILE

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Specifying a Variable Frequency Drive s

Inverter / Charger Installation General Operations and AC and DC Connections

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Wires & Connections Component Circuit Symbol Function of Component. Power Supplies Component Circuit Symbol Function of Component

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

The Do s and Don ts of Pressure Transducers

PLC Based Liquid Filling and Mixing

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

SECTION VARIABLE FREQUENCY DRIVES

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

more than a breaker it s a breakthrough Compact NSX

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Reverse-feed applications for circuit breakers

GROUND DETECTION CIRCUITS FOR STATIONARY APPLICATIONS (IN PLAIN DOWN TO EARTH LANGUAGE)

Everything you need for protection scheme testing

Eaton s E-Series protective relay family

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Unified requirements for systems with voltages above 1 kv up to 15 kv

Digital Systems Based on Principles and Applications of Electrical Engineering/Rizzoni (McGraw Hill

Safety technique. Emergency stop module BO 5988 safemaster

Table of Contents. TransformerIQ FAQs 1

Micro-Step Driving for Stepper Motors: A Case Study

LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS

DMS - Breakthrough Technology for the Smart Grid

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers

An Alternative Approach to Improving SAIDI and SAIFI Indicators

Typical Data Requirements Data Required for Power System Evaluation

32VFD Variable Frequency Drives for Centrifugal Chillers

Switchgear and Metal-Enclosed Bus

3) What is the difference between "Insulating", "Isolating", and "Shielded Winding" transformers?

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Design And Implementation Of Bank Locker Security System Based On Fingerprint Sensing Circuit And RFID Reader

GE Protection and Control Business Department. Page 1 Date 5/11/99

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

understanding medium frequency induction melting furnace and its components

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Capacitor Voltage Transformer. Answers for energy.

Voltage Regulator SPAU 341 C. Product Guide

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

PROGRAM CRITERIA FOR ELECTRICAL ENGINEERING TECHNOLOGY

Engineering innovation

Transcription:

DISTRIBUTION TRANSFORMER OVERLOAD PROTECTION TRIPPING CIRCUIT Dr. Dipesh Patel 1, Jigar Juthani 2, Harsh Parikh 3, Rushit Bhavsar 4, Ujjaval Darbar 5 1 Head of Electrical Department, BITS edu campus, Vadodara 2 BITS edu campus, Vadodara 3 BITS edu campus, Vadodara 4 BITS edu campus, Vadodara 5 BITS edu campus, Vadodara ABSTRACT Distribution transformer is an essential link in the distribution system. Failure of distribution transformers causes capital loss and loss of revenue to the nation. With the increasing loads, voltages and short-circuit duty of the distribution substation feeders, distribution over current protection has become more important today than it was even 10 years ago. The ability of the protective equipment to minimize damage when failures do occur and also to minimize service interruption time is demanded not only for economic reasons but also because the general public just expects reliable service. In distribution transformers, the loading on the secondary side increases sometimes due to increased power consumption. Due to this load draws more current from transformer than its rated value. If proper protection is not provided against this overload current then it damages the transformer insulation windings. An overload and fault protector for a distribution transformer or the like is disclosed. A series-connected high range current-limiting MCB is to be installed to protect the transformer from damages due to overloading by instantaneous tripping. It should withstand the initial magnetizing inrush current and should not trip during that period. Keywords: Arduino, Circuit Breaker, Distribution Transformer, Overload 1. INTRODUCTION Some times in pole mounted substations the loading on the secondary side of the distribution transformer increases due to increase in number of consumers or theft of electricity. In such cases, the load tends to draw more current from the transformer. The increased current increase thermal stresses in the winding of the transformer. This causes breakdown of the winding insulation, core damage and increased transformer losses. 2. MOULDED CASE CIRCUIT BREAKER MCCB are currently used in all distribution transformer protection. A thermal circuit breaker is provided in series with the secondary winding of the transformer to protect it under such situations. The specifications of this circuit breaker are provided by the customer to the manufacturer in the tender. The main problem with MCCB is that it takes more time to trip. During this time winding can get damage due to excessive temperature. The following table depicts information about the tripping time for various percentage of overload. The circuit breaker shall have the following time/current characteristics and test will be made with all the three phases loaded. The reference calibration temperature of the breaker shall be 50 degree centigrade. Table 1: Tripping Time for Various Overloads Multiple of normal current Tripping Time setting 1.05 (5%) More than 2.5 hrs 1.1 (10%) Less than 2.5 hrs 1.15 (15%) More than 1 hr and less than 2 hrs Volume 4, Issue 3, March 2015 Page 255

1.2 (20%) More than 0.5 hrs and less than 1 hr 1.3 (30%) Less than 20 minutes 1.4 (40%) Less than 10 minutes 2.5 (150%) Less than 1 minute 6.0 (500%) Less than 5 seconds 8.0 (700%) Less than 40 milliseconds 12.0 (1100%) Instantaneous (less than 20 milliseconds) 3. MONETARY AND FINANCIAL LOSSES The following calculations show the increment in costs to the customers due to delay in transformer MCCB tripping due to overload. This table shows the fixed costs for the repair of a transformer Table 2: Repairing Cost of Transformer Particulars Cost (in Rs.) Unloading charges + Transportation cost 400 (from site to store) Transportation cost ( from store to factory) 400 Repairing charge (after guarantee period) 7000 Transportation cost ( from factory to store) 400 Transportation cost( from store to site) + 400 Loading charges Total 8600 4. OBJECTIVES The objectives of this project are: To design and fabricate over current protection relay using Arduino UNO microcontroller which can operate on the permissible conditions by setting the tripping value. To test unwanted conditions (overload) and when such conditions arise to isolate the fault condition in the shortest time possible. To investigate IDMT curve characteristic 5. METHODOLOGY To overcome the problem of MCCB we are using electronic circuit breaker for better tripping time. In utility and industrial electric power transmission and distribution systems, an electronic circuit breaker uses a microcontroller with software-based protection algorithm for the detection of electrical or process faults. Such circuit breakers are also termed as microprocessor type protective relays. They are functional replacements for electromechanical protective circuit breakers and may include many protection functions in one unit, as well as providing metering, communication, and self-test functions. Figure 1 Block Diagram Volume 4, Issue 3, March 2015 Page 256

An "Electronic Circuit Breaker" is a type of protective relay which operates when the load current exceeds a preset value. In a typical application the over load relay is used for over load protection, connected to a current sensor and calibrated to operate at or above a specific current level. This project will attempt to design and fabricate over current protection relay using Arduino UNO microcontroller. The Arduino UNO microcontroller will cause the circuit breaker to trip when the current from load current reaches the setting value in the Arduino UNO microcontroller. In order to design it, first the load current is needed to be measured in order to monitor it using current sensor including testing the fault and when such condition arise, it will isolate in the shortest time possible without harming any other electrical devices. It will also include developing the algorithm for instantaneous over current relay and IDMT (Inverse Definite Minimum Time) relay for the circuit breaker to trip. In this project, Arduino UNO microcontroller will be used to control and operate the tripping coil in circuit breaker. It is to be noted that one second time delay is given before the Arduino UNO starts to monitor current. This time delay is to avoid nuisance tripping of circuit breaker when there is a flow of magnetizing inrush current when the distribution transformer is initially switched on. Figure 2 Flowchart (Program Logic) 6. PARTS OF THE ELECTRONIC CIRCUIT BREAKER 6.1 Hall Effect Sensor Hall Effect sensor is the one of the type of magnetic sensor. A Hall Effect sensor is a transducer that varies its output voltage in response to a magnetic field. In its simplest form, the sensor operates as an analog transducer, directly returning a voltage. With a known magnetic field, its distance from the Hall plate can be determined. Using groups of sensors, the relative position of the magnet can be deduced. Frequently, a Hall sensor is combined with circuitry that allows the device to act in a digital (on/off) mode, and may be called a switch in this configuration. The output of the hall sensor varies the supply current. It can be then utilized to display the measured current in an ammeter or can be stored for further analysis in a data acquisition system or can be utilized for control purpose. 6.2 Signal Conditioning Circuit Signal conditioning means manipulating an analog signal in such a way that it meets the requirements of the next stage for further processing. Most common use is in analog-to-digital converters. In control engineering applications, it is common to have a sensing stage (which consists of a sensor), a signal conditioning stage (where usually amplification of the signal is done) and a processing stage (normally carried out by an ADC and a microcontroller). Operational amplifiers (op-amps) are commonly employed to carry out the amplification of the signal in the signal conditioning stage. Volume 4, Issue 3, March 2015 Page 257

6.3 Controller Unit Controller unit is the heart of the robot. For this project we used Arduino UNO microcontroller kit to control the circuit breaker according to the current sensor output. A program is written on the controller so that it collects the current sensor data and sends a message to the relay circuit that an overload has occurred and issues a trip command to it. 6.4 Power Supply It is the major need for the circuit breaker to function in a proper manner. The circuit breaker, relay, microcontroller, display and controls needs 5V DC input for proper functioning. So 5V supply circuit is mounted on the circuit breaker. 6.5 Relay It is an electromagnetic switch used to control the electrical devices. Relay is a passive device that can only be ON or OFF state by default. As such it does not actually know if when it should start to operate and when it should not. Active device that can actually see or sense the fault is required to instruct the relay on what to do. These devices are then connected to the relay input to make a mini protection scheme that can actually monitor faults and take necessary action. To be able to do a good job, the protection scheme should be able to eliminate the fault condition on the smallest portion of the circuit in the shortest time possible. 6.6 Circuit Breaker A circuit breaker as a device designed to open and close a circuit by no automatic means, and to open the circuit automatically on a predetermined over current without damage to itself when properly applied within its rating. In addition, circuit breakers provide automatic over current protection of a circuit. Every circuit breaker has a specific ampere, voltage, and fault current interruption rating. The ampere rating defines the maximum current a circuit breaker can carry without tripping. The ratings of the circuit breaker depend on networks installed. The larger network the larger ratings 6.7 Display and Controls The LCD displays the measured current from the distribution transformer. It also shows the pre-set value of the overload current. The control buttons will help to vary the value of the pre-set threshold overload current. 7. CONCLUSION From this project we can i. Measure and analyze load current from current sensor. The load current (energizing current) will be measured by using current sensor and converted from analog voltage to digital using Arduino UNO microcontroller. Then the load current will be displayed on the LCD. ii. Trip circuit breaker using Arduino UNO microcontroller. The overload value is set in the microcontroller and when faults (over loading) occur, microcontroller will energize the circuit breaker tripping coil which will cause the circuit breaker to trip. iii. Develop algorithm for instantaneous overload relay and IDMT relay. The over current setting may be given by definite time or inverse definite minimum time (IDMT) characteristic. There are four curves for over current complying with the IEC 255 and are named Normal Inverse, Very Inverse, Extremely Inverse and Long Time Inverse. This project is to develop the Long time Inverse characteristic of IDMT. References [1] Power System Protection and Switchgear by B.Ravindranath, M.chander [2] Switchgear Protection And Power Systems by Sunil S.Rao [3] Power System Protection & Switchgear by Oza [4] Fundamentals of Power System Protection by By Yeshwant G. Paithankar, S. R. Bhide [5] Hall-Effect Sensors: Theory and Application By Edward Ramsden [6] Arduino Workshop: A Hands-On Introduction with 65 Projects By John Boxall [7] The 8051 Microcontroller and Embedded Systems: Using Assembly and C By Mazidi Muhammad Ali [8] Arduino Microcontroller: Processing for Everyone! By Steven F. Barrett [9] Protective Relay Principles By Anthony F. Sleva [10] High Voltage Circuit Breakers: Design and Applications By Ruben D. Garzon [11] Microprocessor based moulded case circuit breakers Craig, T. Developments in Power System Protection, 1993., Fifth International Conference on Publication Year: 1993, Page(s): 224 227 [12] Over current protection relay using pic micro controller by zoolnasri bin abu harun. Volume 4, Issue 3, March 2015 Page 258

[13] Blower, R.W, Klaus, D.W. Adams Trends in distribution transformer protection Third International Conference IET conference Publication Year: 1990 [14] Thien-Bach Huynh, Leon Hardy, Mark Pezzo, and Otis Wilder The Testing and Design of an Arduino Microcontroller Board for the Study of Proxemics University of South Florida St. Petersburg Student Research Journal Volume 2 Issue 1: 01 October 2012 [15] Don Wilcher, Learn Electronics with Arduino, illustrated Edition, Apress, 2012 [16] Power quality improvement with Static Compensator on grid integration of wind energy system by DM Patel. Nirma University International Conference on, 2011 [17] Application of static compensator to improve the power quality of grid connected induction generator based wind farm by DM Patel. Advances in Engineering, Science and Management 2012 Volume 4, Issue 3, March 2015 Page 259