3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve



Similar documents
3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

4/2-Way Pneumatic Solenoid Valve

3/2-way Solenoid Valve, direct-acting, NC or NO

type V46, solenoid or pneumatic operated

3/2-way Mini Solenoid Valve

Control- and feedback head for integrated mounting on Robolux valves Type 2036

2.12. page Products for Explosion hazardous Environment

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

System 8. ü ( System 8

Single sub-base valve

3/2-way pneumatic cartridge solenoid valve

Cable Plug acc. to DIN EN , Form A

Electro-pneumatic control valves

Solenoid Valve Island Type 3965

Assisted lift operated 2/2-way solenoid valves Type EV250B

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Inductive sensor NI10-M18-Y1X-H1141

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

SOLENOID VALVES AND PNEUMATIC VALVES

Compact pressure switch Flameproof enclosure Ex d Model PCA

Proportional pressure regulators VPPE

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Technical Data. Dimensions

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Solenoid valves VOFC Key features

G1/4 Q8. Standard with biased position

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Solenoid Valve Type 3962

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical Data. Dimensions

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Plastic tube flowmeters Series PT/PS

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

On-off valves MS-EM/EE, MS series, NPT

Flow switches Series AD/VH

servo-controlled 3-WaY vacuum solenoid valves WiTH

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

Series 8146/5-V37 and Series 8150/5-V37

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Linear Luminaire with LED Series EXLUX 6402/2

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

How To Use A Flowmeter

Control and Distribution Boxes made of Stainless Steel Series 8150

Electric Rotary Actuator - On/Off or programmable control actuator

Terminal Boxes Series 8146

3/2- and 2/2-way cartridge valve type BVE

Directional seated valves type VP 1

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

4 Posiflow Proportional Solenoid Valves

3 Port Solenoid Valve

2/2 & 3/2 Solenoid operated valves

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Plug and Socket Devices CES 63 A Series 8579

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

2/2 and 3/2 Way Size 6 Seat Valves

Digital inductive conductivity transmitter

Solenoid valves Type EVU

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Control block VOFA with safety function

Type 3353 Angle Seat Valve

Explosion proof enclosures

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Instruction Manual Differential Pressure Transmitter

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

A good connection. International approvals.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Inductive slot sensor

VSO MAX HP High Flow Proportional Valve

Plug and Socket Devices SolConeX 16 A Series 8570

Line-Mounted Valves L Series

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Valve systems Base plates, according to standard ISO Brochure

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Solenoid valves 2/2-way direct-operated Type EV210A

Pressure transmitter For general industrial applications Model A-10

Valves. Sub-Base Mounted Valves to ISO 5599/2

3 Port Solenoid Valve

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Turbine Flow Sensor Series VTR

Thermometer in stainless steel with capillary and switch contacts

Flameproof Audible Signal 115 db (A) Series YA90

ISO/VDMA Actuators. Engineering GREAT Solutions

Solenoid/pneumatic valves, Tiger Classic

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

Operating Instructions

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Transcription:

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve Type 6518 Type 6519 Type 6518/6519 can be combined with... Single or block mounting Suitable for outdoor and chemical atmospheres Suitable for low temperatures Explosion-proof versions Threaded or NAMUR flange connections Type 2508 Cable plug Type 2513 Cable plug (ATEX Cat. 3 GD) Type 2510/11 Cable plug ASI Type 20 Single seat valve Type 2030 Diaphragm valve The Type 6518 is a servo-assited 3/2 way valve and the Type 6519 is a 5/2, 5/2-bistable or 5/3 way valve. Together, they form a product line. The valves can be used individually, in blocks or as NAMUR-valves. The valves work without a continuous air consumption and are used for the pneumatic control of double or single-acting actuators. Type 6519 made in high-quality aluminum or stainless-steel makes it possible to use these valves in extreme temperatures or under chemical atmospheres. Solenoid valve, Type 6014, is used as a pilot in all versions. The product line includes devices with Ex-approval and NAMUR-flange. The valves with circuit function C, D and H monostable can achieve SIL2 in according with IEC 61508. Content 6518/6519 Page 6518/6519 Standard temperature range 6518/6519 Standard 2 Ex m 3 Ex i 4 6519 NAMUR Standard 5 Ex m 6 Ex i 7 Manifold assembly with MP07 pneumatic modules 8 Accessories 10 Dimensions 6519 with extended temperature range 6519 Standard 20 Ex m 22 Ex i 6519 NAMUR Standard 26 Ex m 28 Ex i 30 Accessories Dimensions 34 www.burkert.com S. 1/37

Type 6518/6519 Standard (with tag connector acc.to DIN EN 175301-803 Form A, without cable plug) 1) Measured at valve outlet at 6 bar and +20ºC acc. to ISO 238. Opening: Pressure rise 0 to 90%, Closing: Pressure drop 100 to 10% Type 6518 Standard Type 6519 Standard Type 6518 and the Type 6519 together form a product line. Both types can be mounted on a pneumatic module. The valve width of mm allows high flow rates. A solenoid valve Type 6014 is used as a pilot. The valves can be used individually or in blocks. Power consumption Inrush Hold (hot coil) AC [VA] AC [VA/W] DC [W] 11 6/2 2 Response times 1) Opening Closing 20 [ms] 40 [ms] Technical data Orifice Type 6518 Type 6519 Body material Type 6518 Pilot and main valve Type 6519 Pilot valve Main valve Threaded socket material Seal material Type 6518 Type 6519 Medium DN8 mm DN8 and 9 mm Polyamide, reinforced glass-fi bre Polyamide, reinforced Polyamide (5/2 way), aluminium (5/3 way) Brass (stainless steel on request) NBR and PUR NBR and PUR (5/2 way), NBR (5/3 way) Neutral Medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.4.4* Medium temperature -10 C to +50 C Ambient temperature -25 C to +55 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, multi-station manifold (on request NPT 1/4) Thread G 1/4 (on request NPT 1/4) Operating voltages V DC / 110/ 230 V/ 50-60 Hz Voltage tolerance +10% Duty cycle 100% continuous operation Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 Type of protection IP65 with cable plug Installation As required, preferably with actuator upright * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Ordering chart with manual override (without manual override on request) Circuit function 5/2 way valve, servo-assisted, in deenergized position port 2 pressurized, port 4 exhausted L 4 2 Orifice [mm] Seal material and body Threaded port connection [inch] Q Nn value air 1) [l/min] Pressure range 2) [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] Type 6518 Standard Brass threaded socket, also threads 1 and 3 of multi-station manifold; without cable plug C 2 8.0 NBR and G 1/4 1300 2-8 370 2 0/DC 1 457 PUR 10 0/50-60 1 458 1 3 (Polyamide) 110/50-60 1 459 3/2 way valve, servo-assisted, in de-energized position port 2 exhausted 230/50-60 1 460 D 2 8.0 NBR and G 1/4 1300 2-8 370 2 0/DC 1 461 10 PUR 0/50-60 1 462 1 3 (Polyamide) 110/50-60 1 463 3/2 way valve, servo-assisted, in deenergized position port 2 pressurized 230/50-60 1 464 Type 6519 Standard Brass threaded socket, also threads 1, 3 and 5 of multi-station manifold; without cable plug H 14 8.0 NBR and G 1/4 1300 2-8 450 2 0/DC 1 465 PUR (Polyamide) 0/50-60 1 466 14 5 3 1 5/3 way valve, servo-assisted, in middle position all ports locked N 4 2 14 5 3 1 5/3 way valve, servo-assisted, in middle position ports 2 and 4 exhausted 9.0 NBR (Aluminium) 9.0 NBR (Aluminium) 110/50-60 1 467 230/50-60 1 468 G 1/4 1300 3-10 720 2 0/DC 1 469 0/50-60 1 470 110/50-60 1 471 230/50-60 1 472 G 1/4 1300 3-10 720 2 0/DC 1 473 0/50-60 1 474 110/50-60 1 475 230/50-60 1 476 1) Flow rate: QNn value air [l/min]: Measured at +20 C, 6 bar pressure at valve inlet and 1 bar pressure difference 2) Pressure values [bar]: Overpressure with respect to atmospheric pressure S. 2/37

Type 6518/6519 Ex m (with moulded cable, 3 m long, junction box on request) The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Type 6518 Ex m Type 6519 Ex m The approval Ex m is achieved by the mounting of an approved push-over coil. The cable connection and the cable are non-detachable and sealed together with the valve. The valves can be used individually or in blocks. Response times 1) Opening Closing 20 [ms] 50 [ms] 1) Measured at valve outlet at 6 bar and +20ºC acc. to ISO 238. Öffnen: Pressure rise 0 to 90% Closing: Pressure drop 100 to 10% Technical data Orifice Type 6518 Type 6519 Body material Type 6518 - Pilot & main valve Type 6519 - Pilot valve Main valve Threaded socket material Seal material Type 6518 Type 6519 Medium DN8 mm DN8 and 9 mm Ordering chart with manual override (without manual override on request) Polyamide, reinforced glass-fi bre Polyamide, reinforced glass-fi bre Polyamide (5/2 way), aluminium (5/3 way) Brass (stainless steel on request) NBR and PUR NBR and PUR (5/2 way), NBR (5/3 way) Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.4.4* Medium temperature -10 C to +50 C Ambient temperature -25 C to +50 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, multi-station manifold (on request NPT 1/4) Thread G 1/4 (on request NPT 1/4) Operating voltages / 110/ 230 V/UC Voltage tolerance +10% Duty cycle 100% continuous operation Electrical connection 3 m cable, moulded junction box (without fuse) Type of protection IP65 Approvals Coil Junction box Installation PTB 14 ATEX 2023 X / IECEx PTB 14.0049 X II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T 100 C Db EPS16 ATEX 1046 X / IECEx EPS 16.0021 X II 2G EX eb mb IIC T5 Gb II 2D EX mb tb IIIC T100 C Db As required, preferably with actuator upright * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Circuit function Orifice [mm] Seal material and body Threaded port connection [inch] Q Nn value Luft 1) [l/min] Pressure range 2) [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] Type 6518 Ex m Brass threaded socket, also threads 1 and 3 of multi-station manifold; with moulded cable, 3 m long 3) C 2 8.0 NBR G 1/4 1300 2-8 600 3 0/UC 278 195 10 and 110/UC 278 200 1 3 PUR 3/2 way valve, servo-assisted, in (Polyamide) 230/UC 278 201 de-energized position port 2 exhausted D 2 8.0 NBR G 1/4 1300 2-8 600 3 0/UC 278 205 10 and 110/UC x 1 3 PUR 3/2 way valve, servo-assisted, in deenergized (Polyamide) 230/UC x position port 2 pressurized Type 6519 Ex m Brass threaded socket, also threads 1, 3 and 5 of multi-station manifold; with moulded cable, 3 m long 4) H 14 8.0 NBR G 1/4 1300 2-8 700 3 0/UC 278 209 and 110/UC 278 2 PUR 230/UC 278 213 5/3 way valve, servo-assisted, in middle (Polyamide) position ports 2 and 4 exhausted L 9.0 NBR G 1/4 1300 3-10 1.100 3 0/UC 278 221 4 2 (Aluminium) 110/UC x 14 5 3 5/3 way valve, servo-assisted, 1 in middle 230/UC x position all ports locked N 4 2 9.0 NBR G 1/4 1300 3-10 1.100 3 0/UC 278 222 (Aluminium) 14 110/UC x 5 3 1 5/3 way valve, servo-assisted, in middle position ports 2 and 4 exhausted 230/UC x 1) Flow rate: QNn value air [l/min]: Measured at +20 C, 6 bar pressure at valve inlet and 1 bar pressure difference 2) Pressure values [bar]: Overpressure with respect to atmospheric pressure 3) Versions with junction box on request 4) Circuit function H (5/2 way) as impulsee version on request S. 3/37 x = on request

Type 6518/6519 Ex i (with Tag connector acc. to DIN EN 175301-803 Form A, without cable plug) The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Type 6518 Ex i Type 6519 Ex i The intrinsically-safe Type 6518 Ex i and 6519 Ex i valves consist of an intrinsically-safe pilot control and a pneumatic amplifier. The diaphragm-controlled valve seats work with very low friction, ensuring reliable switching of the valve, even after long shutdown periods. Response times 1) Opening Closing 75 [ms] 115 [ms] 1) Measured at valve outlet at 6 bar and +20ºC acc. to ISO 238. Opening: Pressure rise 0 to 90% Closing: Pressure drop 100 to 10% Note These units may only be used in explosive atmospheres in the manner approved by the Federal Institute of Physics and Technology (PTB), i.e., the permissible maximum electrical values must be complied with. Suitable barriers and isolating modules are available for this. The valve is intended for operation on VDC outputs via the intermediate switching of a corresponding intrinsically-safe operating resource (isolating module or barrier). If required, request the Recommended Barrier and Isolating Module data sheet. Technical data Orifice Type 6518 Type 6519 DN8 mm DN8 and 9 mm Body material Pilot valve Main valve Stainless steel 1.4305 or brass Polyamide, reinforced glass-fi bre Threaded socket material Brass (stainless steel on request) Seal material FPM, NBR and PUR Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.4.4* Medium temperature -10 C to +50 C Ambient temperature -25 C to +55 C Pneumatic connection Supply port connection 1, 3, 5 Thread G 1/4, multi-station manifold (on request PT1/4) Service port 2, 4 Duty cycle Electrical connection Type of protection Installation Electrical data - Coil AC10 Ex i Approvals PTB 01 ATEX 2101 / PTB IECEx 10.0019 II 2G Ex ia IIC T6 Gb II 2G Ex ia IIIC T80 C Db Function values for Switching function valve 1) at +20 C at +55 C Minimum switching current Nominal resistance coil Minimum terminal voltage Conformity specifications Ui Ii Pi 1) With high resistance coil on request Thread G 1/4 (on request NPT 1/4) 100% continuous operation Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 (not in delivery, see accessories), check for correct polarity IP65 with cable plug As required, preferably with actuator upright * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. 29 ma 310 Ω 9.0 V 35 V 0.9 A 1.1 W 29 ma 360 Ω 10.4 V Ordering chart for valves without manual override (with manual override and high resistance coil on request) Circuit function Type 6518 Ex i without cable plug C 2 1 3/2 way valve, servo-assisted, in deenergized position port 2 exhausted Type 6519 Ex i without cable plug H 14 5/2 way valve, servo-assisted, in de-energized position port 2 pressurized, port 4 exhausted 3 10 Orifice [mm] 8.0 8.0 Seal material and body NBR and PUR (Polyamide) NBR and PUR (Polyamide) Threaded port connection [inch] Q Nn value Luft 1) [l/min] Pressure range 2) [bar] Weight [g] G 1/4 1300 2-8 580 G 1/4 1300 2-8 670 1) Flow rate: QNn value air [l/min]: Measured at +20 C, 6 bar pressure at valve inlet and 1 bar pressure difference 2) Pressure values [bar]: Overpressure with respect to atmospheric pressure Body material pilot valve St. St. 1.4305 Brass St. St. 1.4305 Brass Material air control connector St. St. 145 111 Brass, nickel plated 144 486 Brass, nickel plated 147 253 St. St. Brass, nickel plated Brass, nickel plated 144 484 144 485 147 252 S. 4/37

Type 6519 NAMUR Standard (with Tag connector acc. to DIN EN 175301-803 Form A, without cable plug) Type 6519 NA- MUR Standard The valve bodies of Type 6519 NAMUR are identical with the Ex m variants. The difference is in the coils, which are laid out and approved in different ways. By changing the coil on the valve body, it is possible to easily convert from Non-Ex operation to Ex operation (or vice versa). The coils are designed to be push-over and can be locked in 4 x 90 displaced positions and be positioned any where in-between. Technical data Orifice Type 6519 DN6 mm Body material Type 6519 Pilot and main valve Polyamide, reinforced glass-fi bre Threaded socket material Brass (stainless steel on request) Seal material Type 6519 NBR and PUR Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.4.4* Medium temperature -10 C to +50 C Ambient temperature -25 C to +55 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, (on request NPT 1/4) NAMUR Flange Operating voltages V DC / 110/ 230 V/ 50-60 Hz Voltage tolerance +10% Duty cycle 100% continuous operation Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 Type of protection IP65 with cable plug Installation As required, preferably with actuator upright * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Power consumption Inrush Hold (hot coil) AC [VA] AC [VA/W] DC [W] 11 6/2 2 Response times 1) Opening Closing 20 [ms] 40 [ms] 1) Measured at valve outlet at 6 bar and +20ºC acc. to ISO 238. Opening: Pressure rise 0 to 90%, Closing: Pressure drop 100 to 10% Ordering chart with manual override (without manual override on request) Circuit function Orifice [mm] Seal material and body Material sockets 1) Threaded port connection [inch] Q Nn value Luft 2) [l/min] Pressure range 3) [bar] Weight [g] Elecrical nominal power [W] Voltage/ Frequency [V/Hz] C 3/2 way valve with exhaust recycling, in de-energized position port 2 fed back internally or 4 2 315 6.0 NBR and PUR Stainless steel G 1/4 900 2-8 460 2 0/DC 131 425 0/50-60 131 426 110/50-60 131 427 230/50-60 131 428 0/DC 131 421 H 14 5/2 way valve, servo-assisted, in deenergized position pressure port 1 connected to port 2, output 4 exhausted 6.0 NBR and PUR Brass, nickel plated G 1/4 900 2-8 460 2 0/50-60 131 422 110/50-60 131 423 230/50-60 131 4 1) When the connecting sockets are made of stainless steel, then the mounting screws are also made of stainless steel 2) Flow rate: QNn value air [l/min]: Measured at +20 C, 6 bar pressure at valve inlet and 1 bar pressure difference 3) Pressure values [bar]: Overpressure with respect to atmospheric pressure All valves can be operated in circuit function C as well as in circuit function H. By replacing the adapter plate that comes with the valves, the change between the two circuit functions can be set up. S. 5/37

Type 6519 NAMUR Ex m (with moulded cable) or Ex me (with junction box) The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Type 6519 NAMUR Ex m Type 6519 NAMUR Ex m NAMUR valve for process plants switches reliably, even when fully restricted. The valve made out of premium polyamide can be operated either as a 5/2 or a 3/2 way version through different mounting plates. The solenoid valve Type 6014 with a coil approved for use in hazardous areas is connected as a pilot. The NAMUR flange interface allows easy assembly on different pneumatic actuators on the spot. The valve bodies are identical with the Type 6519 NAMUR standard version. The difference between the valves is in the coils, which are laid out and approved in different ways. By changing the coil on the valve body, it is possible to easily convert from Non-Ex operation to Ex operation (or vice versa). Coil versions with moulded cable are designed to be push-over and can be locked in 4 x 90 displaced positions and be positioned any where in-between. Technical data Orifice DN6 mm Body material Pilot and main valve Polyamide, reinforced glass-fi bre Threaded socket material Brass (stainless steel on request) Seal material NBR and PUR Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.4.4* Medium temperature -10 C to +50 C Ambient temperature -25 C to +50 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, (on request NPT 1/4) NAMUR Flange Operating voltages / 110/ 230 V/UC Voltage tolerance +10% Duty cycle 100% continuous operation Electrical connection 3 m cable, moulded junction box (without fuse) Type of protection IP65 Approvals Coil PTB 14 ATEX 2023 X / IECEx PTB 14.0049 X II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T 100 C Db Junction box EPS16 ATEX 1046 X / IECEx EPS 16.0021 X II 2G EX eb mb IIC T5 Gb II 2D EX mb tb IIIC T100 C Db Installation As required, preferably with actuator upright * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Response times 1) Opening Closing 20 [ms] 40 [ms] 1) Measured at valve outlet at 6 bar and +20ºC acc. to ISO 238. Opening: Pressure rise 0 to 90%, Closing: Pressure drop 100 to 10% Ordering chart with manual override (without manual override on request) Circuit function Orifice [mm] Seal material and body Material sockets 1) Threaded port connection [inch] Q Nn value Luft 2) [l/min] Pressure range 3) [bar] Weight [g] Electrical Nominal power [W] Voltage/ Frequency [V/Hz] C 3/2 way valve, with exhaust air return, in de-energized position port 2 exhausted internally or H 14 4 2 315 5/2 way valve, servo-assisted, in de-energized position pressure port 1 connected to port 2, port 4 exhausted Version acc. to Ex m, with moulded 3 m-cable 6.0 NBR and PUR Stainless steel Brass, nickel plated G 1/4 900 2-8 650 3 G 1/4 900 2-8 650 3 Version acc. to Ex me, with junction box without fuse 6.0 NBR and PUR Stainless steel Brass, nickel plated G 1/4 900 2-8 690 3 G 1/4 900 2-8 690 3 1) When the connecting sockets are made of stainless steel, then the mounting screws are also made of stainless steel 2) Flow rate: QNn value air [l/min]: Measured at +20 C, 6 bar pressure at valve inlet and 1 bar pressure difference 3) Pressure values [bar]: Overpressure with respect to atmospheric pressure 0/UC 278 231 110/UC 278 234 230/UC 278 237 0/UC 278 228 110/UC 278 235 230/UC 278 239 0/UC 289 407 230/UC 289 415 0/UC 289 406 110/UC 289 4 230/UC 289 414 x on request All valves can be operated in circuit function C as well as in circuit function H. By replacing the adapter plate that comes with the valves, the change between the two circuit functions can be set up. S. 6/37

Type 6519 NAMUR Ex i (with Tag connector acc. to DIN EN 175301-803 Form A, without cable plug) The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. The Type 6519 NAMUR Ex i valve is used for the pneumatic control of double or single-acting actuators with a NAMUR adapter plate flange. The circuit function can easily be changed using an adapter plate. In the 3/2 way function, feedback of the exhaust air takes place in the spring area of the armature drive. The diaphragm-controlled valve seats work with very low friction, ensuring reliable switching of the valve even after long shutdown periods and at ambient temperatures below 0 C. The valves work without a continuous air consumption. Note The units may only be used in explosive atmospheres in the manner approved by the Federal Institute of Physics and Technology (PTB), i.e., the permissible maximum electrical values must be complied with. Suitable barriers and isolating modules are available for this. Ordering chart for valves without manual override (with manual override and high resistance coil on request) without cable plug Type 6519 NAMUR Ex i The valve is intended for operation on VDC outputs via the intermediate switching of a corresponding intrinsicallysafe operating resource (isolating module or barrier). If required, request the Recommended Barrier and Isolating Module data sheet. Technical data Orifice Body material Pilot valve Main valve Threaded socket material Seal material Medium Electrical data Approvals PTB 01 ATEX 2101 / PTB IECEx 10.0019 II 2G Ex ia IIC T6 Gb II 2G Ex ia IIIC T80 C Db Function values for Switching function valve 1) at +20 C at +55 C Minimum switching current Nominal resistance coil Minimum terminal voltage Conformity specifications Ui Ii Pi 1) With high resistance coil on request DN6 mm Stainless steel 1.4305 or brass Polyamide, reinforced glass-fi bre Brass (stainless steel on request) FPM, NBR and PUR Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.4.4* Medium temperature -10 C to +50 C Ambient temperature -25 C to +55 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, (on request NPT 1/4) NAMUR Flange Duty cycle 100% continuous operation Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 (not in delivery, see accessories), check for correct polarity Type of protection IP65 with cable plug Installation As required, preferably with actuator upright * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. 1) Measured at valve outlet at 6 bar and +20ºC acc. to ISO 238. Response times 1) [ms] Opening: Pressure rise 0 to 90% Opening 75 Closing: Pressure drop 100 to 10% Closing 115 29 ma 310 Ω 9.0 V 35 V 0.9 A 1.1 W 29 ma 360 Ω 10.4 V Circuit function Orifice [mm] Seal material and body Threaded port connection [inch] Q Nn value Luft 1) [l/min] Pressure range 2) [bar] Weight [g] Body material pilot valve Material air control connector C 3/2 way valve, with exhaust air return, in deenergized position port 2 exhausted internally or H 14 4 2 315 5/2 way valve, servo-assisted, in de-energized position pressure port 1 connected to port 2, port 4 exhausted 6.0 NBR and PUR (Polyamide) G 1/4 900 2-8 670 1) Flow rate: QNn value air [l/min]: Measured at +20 C, 6 bar pressure at valve inlet and 1 bar pressure difference 2) Pressure values [bar]: Overpressure with respect to atmospheric pressure St. St. 1.4305 Brass St. St. 144 482 Brass, nickel plated Brass, nickel plated All valves can be operated in circuit function C as well as in circuit function H. By replacing the adapter plate that comes with the valves, the change between the two circuit functions can be set up. All valves have mounting plates and tag connectors acc. to DIN EN 175301-803 Form A (previously DIN 43650) and are supplied without cable plug 144 483 147 4 S. 7/37

Pneumatic modules Type MP07 Single modules or pre-mounted blocks are available. Example of a complete valve block Connector module, left Pneumatic basic module, 3 valves Pneumatic intermediate supply module: supply channel pushed through for additional pressure supply or Connector module, right: supply channel closed off, thereby several operational pressures possible in a single block Pneumatic basic module, 2 valves Connector module, right Supply ports 3(R) Covering plate for 3/2 way valves (to cover up unused ports) 5(S) Note when ordering complete valve blocks: Please list the modules in the block assembly from right to left, as shown in the ordering example. Valves with NAMUR Flange. Ex i coil or Ex versions with junction boxes are not suitable for block mounting. Ordering example for Type 6518 with Type MP07 No. Unit 1 Connector module right, G 1/2 635 331 1 Pneumatic basic module, 2 valves 635 319 1 Pneumatic basic module, 3 valves 635 343 1 Connector module left, G 1/2 635 3 5 Valves 1 457 Ordering chart for Type MP07 pneumatic modules Version Connector module right G 1/2 635 331 Intermediate supply module 637 505 Pneumatic basic module, 2 valves universal (for 3/2-, 5/2- and 5/3 way) 635 319 Pneumatic basic module, 3 valves universal (for 3/2-, 5/2- and 5/3 way) 635 343 Connector module left G 1/2 635 3 Covering plate for 5/2- and 5/3 way (to cover unused valve positions) 635 335 Covering plate for 3/2 way (to cover unused connections) 635 337 S. 8/37

Type MP07 pneumatic modules, continued Dimensions for Type MP07 pneumatic modules [mm] Manifold assembly either wall-mounted or standard mounting DIN rail 50022 or 50023 59 + (n x 33) 101,5 65 5/3, 5/3 - Impuls 15 35 4255 5/2 ø 5,5 115 108 102,5 3 1 1 3 58 92 0 182 100 82 4,8 9 57,5 48 5 5 10 G 1/8 NPT 1/8 33 G 1/4 NPT 1/4 G 1/2 NPT 1/2 55 6 8 n x 33 87 + (n x 33) 110 + (n x 33) 46 52 90 n=no. of valves, maximum Valve assembly on pneumatic modules Type MP07 using the supplied M4 screws S. 9/37

Accessories Cable plug 2508 acc. to DIN EN 175301-803 Form A The delivery of a cable plug includes the flat seal and the fixing screw. For other cable plug versions acc. to DIN EN 175301-803 Form A (previously DIN 43650) with integrated circuitry, see datasheet Type 2508. Dimensions Type 2508 [mm] Fixing screw Flat seal 18 46 18 27,5 18 46 1,5 M3 28 Ordering chart Cable plug 2508 Beschaltung Voltage For standard version 6518/19 Fixing screw in steel (galvanised and chrome-plated) without circuitry 0-250 V 008 376 with LED - V 008 360 with LED and varistor - V 008 367 with LED and varistor 200-0 V 008 369 For Ex i version 6519 Fixing screw in stainless steel 1.4404 and blue compression gland nut without circuitry 0-250 V 438 574 for further versions see datasheet 2508 Cable plug Type 2513 acc. to DIN EN 175301-803, Form A Meets the requirements of ATEX category 3 GD BN Cable length [mm] [in mm] BU GNYE 000 260 893 5000 260 892 3000 260 891 300 260 890 Ordering chart for further accessories Accessories Features Cap nut Cap nut in stainless steel for additional protection of the exhaust air channel from the penetration of damp 649 554 Blanking plug G 1/8 780 141 G 1/4 780 142 G 1/2 780 144 Silencer G 1/8 005 305 G 1/4 005 064 G 1/2 005 062 Labelling plate 64 pieces 635 416 Semi-delay fuse for 6519 NAMUR Ex m Voltage [V] Max. current [ma] V 315 ma 153 733 110 V 50 ma 153 716 230 V ma 153 715 S. 10/37

Accessories (continued) Ex-Cable glands (polyamide version included in delivery / surcharge applied for brass nickel plated version Ex Approvals Special tool to turn the junction box (not included in delivery) Photo Description Photo Description Certification Identification Item no Drawing Brass. nickelplated, 6-13 mm PTB 04 ATEX 11 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68, 773 278 TL 29-37 mm L 6 mm D 20 SW mm E 27 mm TL 36-45 mm Polyamide, 7-13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 773 277 L 10 mm D 20 SW mm E 28 mm Set SC02-AC10 Special wrench Service Manual 293 488 S. 11/37

Dimensions [mm] Standard versions Type 6518 3/2 way valve, circuit function C and D SW 14 G1/8 45 20.5 138.7 25.5 G1/4 / NPT1/4 4.3 11.2 3 7.9-4.2 deep 13.5 69.6 25.5 43 53 4.3 8-4.3 deep 28.5 8 3-3 tief G1/4 / NPT1/4 Type 6519 5/2 way valve, circuit function H SW 14 G1/8 45 20.5 176.8 11.2 G1/4 / NPT1/4 3 4.3 7.9-4.2 deep 39.6 36 43 53 4.3 8-4.3 deep 107.7 28.5 26.5 G1/4 / NPT1/4 3-3 deep 48 * Mounting length with 2 magnetic coils 9 mm S. /37

Dimensions [mm] Standard versions Type 6519 5/3 way valve, circuit function L and N SW 14 G1/8 45 20.5 G1/4 / NPT1/4 26 4.3 3-3 deep 250.2 43 36 1 50 44 11.2 G1/4 / NPT1/4 4.5 11-3 deep 70 28.5 26.5 48 S. 13/37

Dimensions [mm] Ex m/me versions Type 6518 3/2 way valve, circuit function C and D with moulded cable (3 m long) (Ex m) A SW 14 G1/8 Length acc. to ordering information D C B 138.7 25.5 G1/4 / NPT1/4 4.3 7.9-4.2 deep 10.9 6.2 3 13.5 min. R25 69.6 25 5 43 53 4.3 8-4.3 deep 28.5 8 3-3 deep G1/4 / NPT1/4 with junction box (Ex me) Coil size A B C D E F 5 20.5 46 68.8 99.8 174.7 6 40 23.5 52 74.8 102.8 177.7 68 SW 27 A SW 14 G1/8 F E M20x1.5 B R84 Turning radius 25.5 138.7 G1/4 / NPT1/4 4.3 7.9-4.2 deep 13.5 69.6 84.3 4.3 41.3 8-4.3 deep 25.5 10.9 29.7 3 43 53 S. 14/37

Dimensions [mm] Ex m/me versions Type 6519 5/2 way valve, circuit function H with moulded cable (3 m long) (Ex m) A SW 14 G1/8 length acc. to ordering information D C B 176.85 G1/4 / NPT1/4 39.6 36 43 53 4.3 8-4.3 deep A SW14 G1/8 Length acc. to ordering information D C B 6.2 6.2 4.3 7.9-4.2 deep min. R25 107.75 10.9 28.5 26.5 G1/4 / NPT1/4 3-3 deep 48 250.2 G1/4 / NPT 1/4 10.9 5/2 way valve, circuit function L and N 26 4.5 11-3 deep 70 min. R25 43 50 4.3 44 36 1 28.5 26.5 3-3 deep G1/4 / NPT 1/4 48 S. 15/37

Dimensions [mm] Ex i versions Type 6518 3/2 way valve, circuit function C 40 SW 14 G1/8 51 23,5 145,7 25,5 G1/4 / NPT1/4 4,3 7,9-4,2 tief 13,5 11,2 3 69,6 25,5 43 53 4,3 8-4,3 tief 28,5 8 3-3 tief G1/4 / NPT1/4 Type 6519 5/2 way valve, circuit function H 40 SW 14 G1/8 51 23.5 183.8 G1/4 / NPT1/4 4.3 7.9-4.2 deep 39.6 36 4.3 8-4.3 deep 107.7 26.5 28.5 G1/4 / NPT1/4 48 11.2 3 43 3-3 tief 53 S. 16/37

Dimensions [mm] NAMUR Standard version Type 6519 3/2 way valve, circuit function C or 5/2 way valve, circuit function H SW 14 G1/8 20.5 45 51.6 51.6 48 107.7 5.3 176.8 G1/4 / NPT1/4 11.2 37 3.95 53 S. 17/37

Dimensions [mm] NAMUR Ex m/me version Type 6519 3/2 way valve, circuit function C or 5/2 way valve, circuit function H with moulded cable (3 m long) (Ex m) A SW 14 G1/8 B D C Length acc. to ordering information 51.6 107.7 5.3 6.2 min. R25 51.6 48 176.8 G1/4 / NPT1/4 10.9 37 3.95 53 with junction box (Ex me) Coil size A B C D E F 5 20.5 46 68.8 99.8 174.7 6 40 23.5 52 74.8 102.8 177.7 20.5 E M20x1.5 F 51.6 51.6 48 107.7 G1/4 / NPT1/4 176.8 5.3 41.3 29.7 R84 Turning radius 84.3 SW27 68 37 3.95 53 S. 18/37

Dimensions [mm] NAMUR Ex i version Type 6519 3/2 way valve, circuit function C or 5/2 way valve, circuit function H 40 SW 14 51 G1/8 23.5 51.6 107.7 G1/4 / NPT1/4 5.3 11.2 Aluminium 51.6 48 183.6 37 3.95 53 S. 19/37

6519 for extended temperature range Type 6519 for extended standard temperature range Technical data Aluminium Stainless steel Orifice 9 9 Body material Pilot valve Main valve Stainless steel Aluminium ematal coated Stainless steel Stainless steel 1.4571 Threaded socket material in aluminium in stainless steel Seal material FPM, NBR PU, NBR, FPM Medium Neutral medium, eg lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.2.4* Medium temperature -30 C to +80 C -30 C to +80 C Ambient temperature -40 C to +80 C -30 C to +80 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Operating voltages Thread G 1/4, (on request NPT 1/4) Thread G 1/4 (on request NPT 1/4) V DC / 110/ 230 V/ 50-60 Hz Voltage tolerance +10% Electr. power consumption 2 W Duty cycle 100% continuous operation Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 Type of protection IP65 with cable plug Installation As required, preferably with actuator upright Response times 5/2 5/2-bi 5/3 3/2 5/2 5/2-bi Opening [ms] 16 18 16 13 14 Closing [ms] 27 18 22 47 74 14 * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Ordering chart for valves in aluminium with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material and body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] 5/2 WWH 9.0 FPM, NBR G 1/4 1800 2.5 10 680 2 0/DC 231 386 0/50 60 231 387 14 110/50 60 231 388 230/50 60 231 389 5/2-bistable WWZ 9.0 FPM, NBR G 1/4 2100 2.5 10 990 2 0/DC 231 390 14 0/50 60 231 391 110/50 60 231 392 230/50 60 231 393 5/3 WWL 9.0 FPM, NBR G 1/4 1500 2.5 10 1060 2 0/DC 231 394 14 0/50 60 231 395 110/50 60 231 396 230/50 60 231 397 5/3 WWN 9.0 FPM, NBR G 1/4 1500 2.5 10 1060 2 0/DC 231 399 14 0/50 60 231 400 110/50 60 231 401 230/50 60 231 402 S. 20/37

6519 for extended temperature range Ordering chart for valves in stainless steel with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] 5/2 WWH 8.0 PU, NBR G 1/4 1980 3 10 1370 2 0/DC 231 403 14 0/50 60 231 404 110/50 60 231 405 230/50 60 231 406 5/2-bistable WWZ 8.0 PU, NBR G 1/4 1920 3 10 1680 2 0/DC 231 407 14 0/50 60 231 408 110/50 60 231 409 230/50 60 231 410 5/3 WWL 8.0 PU, NBR G 1/4 1770 3 10 1680 2 0/DC 231 411 14 0/50 60 231 4 110/50 60 231 413 230/50 60 231 414 5/3 WWN 8.0 PU, NBR G 1/4 1770 3 10 1680 2 0/DC 231 415 14 0/50 60 231 416 110/50 60 231 417 230/50 60 231 418 S. 21/37

6519 for extended temperature range Type 6519 for extended Ex m temperature range The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Technical data Aluminium Stainless steel Orifice 9 9 Body material Pilot valve Main valve Stainless steel Aluminium ematal coated Stainless steel Stainless steel 1.4571 Threaded socket material in aluminium in stainless steel Seal material FPM, NBR PU, NBR, FPM Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.2.4* Medium temperature -30 C to +80 C -30 C to +80 C Ambient temperature -40 C to +60 C -30 C to +60 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, (on request NPT 1/4) Thread G 1/4 (on request NPT 1/4) Operating voltages V DC / 110/ 230 V/ 50-60 Hz Voltage tolerance +10% Electr. power consumption 3 W Duty cycle 100% continuous operation Electrical connection 3 m cable, moulded junction box (without fuse) on request Type of protection IP65 Approvals Coil Junction box Installation PTB 14 ATEX 2023 X / IECEx PTB 14.0049 X II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T 100 C Db EPS16 ATEX 1046 X / IECEx EPS 16.0021 X II 2G EX eb mb IIC T5 Gb II 2D EX mb tb IIIC T100 C Db As required, preferably with actuator upright Response times 5/2 5/2-bi 5/3 3/2 5/2 5/2-bi Opening [ms] 16 18 16 13 14 Closing [ms] 27 18 22 47 74 14 * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Ordering chart for valves in aluminium with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] Type 6519 Ex m - with moulded cable, 3 m long 1) 5/2 WWH 9.0 FPM, NBR G 1/4 1800 2.5 10 680 3 0/UC 278 217 14 110/UC x 230/UC 278 220 5/2-bistable WWZ 9.0 FPM, NBR G 1/4 2100 2.5 10 990 3 0/UC 278 7 14 110/UC x 230/UC x 5/3 WWL 9.0 FPM, NBR G 1/4 1500 2.5 10 1060 3 0/UC x 14 110/UC x 230/UC x 5/3 WWN 9.0 FPM, NBR G 1/4 1500 2.5 10 1060 3 0/UC 278 223 14 110/UC x 230/UC x 1) Junction box version on request x = on request S. 22/37

6519 for extended temperature range Ordering chart for valves in stainless steel with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] Type 6519 Ex m - with moulded cable, 3 m long 1) 5/2 WWH 8.0 PU, NBR G 1/4 1980 3 10 1370 3 0/UC x 14 110/UC x 230/UC 278 219 5/2-bistable WWZ 8.0 PU, NBR G 1/4 1920 3 10 1680 3 0/UC 278 6 14 110/UC x 230/UC x 5/3 WWL 8.0 PU, NBR G 1/4 1770 3 10 1680 3 0/UC x 14 110/UC x 230/UC x 5/3 WWN 8.0 PU, NBR G 1/4 1770 3 10 1680 3 0/UC x 14 110/UC x 1) Junction box version on request 230/UC x x = on request S. 23/37

6519 for extended temperature range Type 6519 for extended Ex i temperature range The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Technical data Aluminium Stainless steel Orifice Type 6519 9 9 Body material Pilot valve Main valve Stainless steel Aluminium ematal coated Stainless steel Stainless steel 1.4571 Threaded socket material in aluminium in stainless steel Seal material FPM, NBR PU, NBR, FPM Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.2.4* Medium temperature -30 C to +80 C -30 C to +80 C Ambient temperature -40 C to +75 C -30 C to +75 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, (on request NPT 1/4) Thread G 1/4 (on request NPT 1/4) Voltage tolerance +10% Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 (not in delivery, see accessories), check for correct polarity Type of protection IP65 with cable plug Installation As required, preferably with actuator upright Response times 5/2 5/2-bi 5/3 3/2 5/2 5/2-bi Opening [ms] 16 18 16 13 14 Closing [ms] 27 18 22 47 74 14 * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Electrical data - coil AC10 Ex i Approvals PTB 01 ATEX 2101 / PTB IECEx 10.0019 II 2G Ex ia IIC T6 Gb II 2G Ex ia IIIC T80 C Db Function values for Switching function valve 1) at +20 C at +55 C Minimum switching current Nominal resistance coil Minimum terminal voltage Conformity specifications Ui Ii Pi 1) With high resistance coil on request 29 ma 310 Ω 9.0 V 35 V 0.9 A 1.1 W 29 ma 360 Ω 10.4 V Note + lmin + SPS V DC barrier Umin These units may only be used in explosive atmospheres in the manner approved by the Federal Institute of Physics and Technology (PTB), i.e., the permissible maximum electrical values must be complied with. Suitable barriers and isolating modules are available for this. The valve is intended for operation on VDC outputs via the intermediate switching of a corresponding intrinsically-safe operating resource (isolating module or barrier). S. /37

6519 for extended temperature range Ordering chart for valves in aluminium with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Ordering chart for valves in stainless steel with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Minimum switching current [ma] Nominal resistance coil [Ohm] Minimum terminal voltage [V] Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Minimum switching current [ma] Nominal resistance coil [Ohm] Minimum terminal voltage [V] 5/2 WWH 9.0 FPM, NBR G 1/4 1800 2.5 10 825 29 310 9 231 452 14 23 481 11 231 453 5/2-bistable WWZ 9.0 FPM, NBR G 1/4 2100 2.5 10 80 29 310 9 231 454 14 23 481 11 231 455 5/3 WWL 9.0 FPM, NBR G 1/4 1500 2.5 10 1350 29 310 9 231 456 14 23 481 11 231 457 5/3 WWN 9.0 FPM, NBR G 1/4 1500 2.5 10 1350 29 310 9 231 458 14 23 481 11 231 459 5/2 WWH 8.0 PU, NBR G 1/4 1980 3 10 1520 29 310 9 231 460 14 23 481 11 231 461 5/2-bistable WWZ 8.0 PU, NBR G 1/4 1920 3 10 1970 29 310 9 231 463 14 23 481 11 231 464 5/3 WWL 8.0 PU, NBR G 1/4 1770 3 10 1970 29 310 9 231 465 14 23 481 11 231 466 5/3 WWN 8.0 PU, NBR G 1/4 1770 3 10 1970 29 310 9 231 467 14 23 481 11 231 468 S. 25/37

6519 for extended temperature range Type 6519 for extended NAMUR standard temperature range Technical data Aluminium Stainless steel Orifice 6 6 Body material Pilot valve Main valve Stainless steel Aluminium ematal coated Ordering chart for valves in aluminium with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Stainless steel Stainless steel 1.4571 Threaded socket material in aluminium in stainless steel Seal material FPM, NBR PU, NBR, FPM Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.2.4* Medium temperature -30 C to +80 C -30 C to +80 C Ambient temperature -40 C to +80 C -30 C to +80 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Operating voltages Thread G 1/4, (on request NPT 1/4) NAMUR Flange V DC / 110/ 230 V/ 50-60 Hz Voltage tolerance +10% Electr. power consumption 2 W Duty cycle 100% continuous operation Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 Type of protection IP65 with cable plug Installation As required, preferably with actuator upright Response times 5/2 5/2-bi 5/3 3/2 5/2 5/2-bi Opening [ms] 16 18 16 13 14 Closing [ms] 27 18 22 47 74 14 * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] 3/2 WWC 6.0 FPM, NBR G 1/4 780 3 10 540 2 0/DC 231 469 2 0/50 60 231 470 10 1 3 110/50 60 231 471 230/50 60 231 472 5/2 WWH 6.0 FPM, NBR G 1/4 800 3 10 540 2 0/DC 231 473 14 0/50 60 231 474 110/50 60 231 475 230/50 60 231 476 5/2-bistable WWZ 6.0 FPM, NBR G 1/4 900 3 10 540 2 0/DC 231 477 14 0/50 60 231 478 110/50 60 231 479 230/50 60 231 480 S. 26/37

6519 for extended temperature range Ordering chart for valves in stainless steel with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] 3/2 WWC 2 6.0 PU, NBR G 1/4 80 3 10 540 2 0/DC 231 481 10 0/50 60 231 482 1 3 110/50 60 231 483 230/50 60 231 484 5/2 WWH 6.0 PU, NBR G 1/4 1060 3 10 540 2 0/DC 231 485 14 0/50 60 231 486 110/50 60 231 487 230/50 60 231 488 5/2-bistable WWZ 6.0 PU, NBR G 1/4 1050 3 10 540 2 0/DC 231 489 14 0/50 60 231 490 110/50 60 231 491 230/50 60 231 492 S. 27/37

6519 for extended temperature range Type 6519 for extended NAMUR Ex m temperature range The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Technical data Aluminium Stainless steel Orifice 6 6 Body material Pilot valve Main valve Stainless steel Aluminium ematal coated Ordering chart for valves in aluminium with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Stainless steel Stainless steel 1.4571 Threaded socket material in aluminium in stainless steel Seal material FPM, NBR PU, NBR, FPM Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.2.4* Medium temperature -30 C to +80 C -30 C to +80 C Ambient temperature -40 C to +60 C -30 C to +60 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Operating voltages Thread G 1/4, (on request NPT 1/4) NAMUR Flange V DC / 110/ 230 V/ 50-60 Hz Voltage tolerance +10% Electr. power consumption 3 W Duty cycle 100% continuous operation Electrical connection 3 m cable, moulded junction box (without fuse) on request Type of protection IP65 Approvals Coil Junction box Installation PTB 14 ATEX 2023 X / IECEx PTB 14.0049 X II 2G Ex mb IIC T5 Gb II 2D Ex mb IIIC T 100 C Db EPS16 ATEX 1046 X / IECEx EPS 16.0021 X II 2G EX eb mb IIC T5 Gb II 2D EX mb tb IIIC T100 C Db As required, preferably with actuator upright Response times 5/2 5/2-bi 5/3 3/2 5/2 5/2-bi Opening [ms] 16 18 16 13 14 Closing [ms] 27 18 22 47 74 14 * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] Type 6519 Ex m - with moulded cable, 3 m long 1) 3/2 WWC 2 6.0 FPM, NBR G 1/4 780 3 10 540 3 0/UC x 10 110/UC x 1 3 230/UC x 5/2 WWH 6.0 FPM, NBR G 1/4 800 3 10 540 3 0/UC 278 207 14 110/UC x 230/UC x 5/2-bistable WWZ 6.0 FPM, NBR G 1/4 900 3 10 540 3 0/UC 278 2 14 110/UC x 230/UC x 1) Junction box version on request x = on request S. 28/37

6519 for extended temperature range Ordering chart for valves in stainless steel with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Nominal power [W] Voltage/ Frequency [V/Hz] Type 6519 Ex m - with moulded cable, 3 m long 1) 3/2 WWC 2 6.0 PU, NBR G 1/4 80 3 10 960 3 0/UC x 10 110/UC x 1 3 230/UC x 5/2 WWH 6.0 PU, NBR G 1/4 1060 3 10 960 3 0/UC x 14 110/UC x 230/UC x 5/2-bistable WWZ 6.0 PU, NBR G 1/4 1050 3 10 60 3 0/UC x 14 110/UC x 230/UC x 1) Junction box version on request x = on request S. 29/37

6519 for extended temperature range Type 6519 for extended NAMUR Ex i temperature range The maximum fluid temperature may never exceed the permissible temperature class (T4 135 C, T5 100 C, T6 85 C) minus 5K. Technical data Aluminium Stainless steel Orifice Type 6519 6 6 Body material Pilot valve Main valve Stainless steel Aluminium ematal coated Stainless steel Stainless steel 1.4571 Threaded socket material in aluminium in stainless steel Seal material FPM, NBR PU, NBR, FPM Medium Neutral medium, e.g. lubricated or non-lubricated compressed air Compressed air quality ISO 8573-1:2010, Class 7.2.4* Medium temperature -30 C to +80 C -30 C to +80 C Ambient temperature -40 C to +75 C -30 C to +75 C Pneumatic connection Supply port connection 1, 3, 5 Service port 2, 4 Thread G 1/4, (on request NPT 1/4) NAMUR Flange Voltage tolerance +10% Electrical connection Tag connector acc. to DIN EN 175301-803 (previously DIN 43650) Form A for cable plug Type 2508 (not in delivery, see accessories), check for correct polarity Type of protection IP65 with cable plug Installation As required, preferably with actuator upright Response times 5/2 5/2-bi 5/3 3/2 5/2 5/2-bi Opening [ms] 16 18 16 13 14 Closing [ms] 27 18 22 47 74 14 * To prevent freezing of the expanded compressed air, the pressure dew point must be at least 10 K lower than the temperature of the medium. Electrical data - coil AC10 Ex i Approvals PTB 01 ATEX 2101 / PTB IECEx 10.0019 II 2G Ex ia IIC T6 Gb II 2G Ex ia IIIC T80 C Db Function values for at +20 C at + 55 C Switching function valve* Minimum switching current 29 ma 29 ma Nominal resistance coil 310 Ohm 360 Ohm Minimum terminal voltage 9.0 V 10.4 V Conformity specifications Ui li Pi 35 V 0.9 A 1.1 W Note + lmin + SPS V DC barrier Umin These units may only be used in explosive atmospheres in the manner approved by the Federal Institute of Physics and Technology (PTB), i.e., the permissible maximum electrical values must be complied with. Suitable barriers and isolating modules are available for this. The valve is intended for operation on VDC outputs via the intermediate switching of a corresponding intrinsically-safe operating resource (isolating module or barrier). S. 30/37

6519 for extended temperature range Ordering chart for valves in aluminium with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Ordering chart for valves in stainless steel with manual override (without manual override on request) All products come with a standard stainless steel cap nut. This cap nut protects the exhaust channel from penetrating humidity. Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Minimum switching current [ma] Nominal resistance coil [Ohm] Minimum terminal voltage[v] Circuit function Orifice [mm] Seal material body Threaded port connection [inch] QNn-value air [l/min] Pressure range [bar] Weight [g] Minimum switching current [ma] Nominal resistance coil [Ohm] Minimum terminal voltage[v] 3/2 WWC 6.0 FPM, NBR G 1/4 780 3 10 690 29 310 9 231 520 2 10 1 3 23 481 11 231 521 5/2 WWH 6.0 FPM, NBR G 1/4 800 3 10 690 29 310 9 231 522 14 23 481 11 231 523 5/2 bistable WWZ 6.0 FPM, NBR G 1/4 900 3 10 1140 29 310 9 231 5 14 23 481 11 231 525 3/2 WWC 6.0 PU, NBR G 1/4 80 3 10 1100 29 310 9 231 526 2 10 1 3 23 481 11 231 527 5/2 WWH 6.0 PU, NBR G 1/4 1060 3 10 1100 29 310 9 231 528 14 23 481 11 231 529 5/2 bistable WWZ 6.0 PU, NBR G 1/4 1050 3 10 1550 29 310 9 231 530 14 23 481 11 231 531 S. 31/37

6519 for extended temperature range Accessories Cable plug 2508 acc. to DIN EN 175301-803 Form A Included in delivery is a connector with flat seal and fixing screw. For other cable plug versions acc. to DIN EN 175301-803 Form A (previously DIN 43650) with integrated circuitry, see datasheet Type 2508. Dimensions Type 2508 [mm] Fixing screw Flat seal 18 46 18 27,5 18 46 1,5 M3 28 Ordering chart for cable plug 2508 Circuit Voltage For standard version 6519 fixing screw in steel (galvanised and chrome-plated) without circuitry 0-250 V 008 376 with LED - V 008 360 with LED and varistor - V 008 367 with LED and varistor 200-0 V 008 369 For Ex i version 6519 Fixing screw in stainless steel 1.4404 and blue compression gland nut without circuitry 0-250 V 438 574 for further versions see datasheet 2508 Cable plug Type 2513 acc. to DIN EN 175301-803, Form A Meets the requirements of ATEX category 3 GD BN Cable length [mm] [in mm] BU GNYE 000 260 893 5000 260 892 3000 260 891 300 260 890 Ordering chart for further accessories Accessories Features Cap nut Cap nut in stainless steel for additional protection of the exhaust channel from penetrating humidity, 649 554 Blanking plug G 1/4 780 142 Silencer G 1/4 005 064 Labelling plate 64 pieces 635 416 Semi-delay fuse for 6519 NAMUR Ex m Voltage [V] Max. current [ma] V 315 ma 153 733 110 V 50 ma 153 716 230 V ma 153 715 S. /37

6519 for extended temperature range Accessories (continued) Ex-Cable glands (polyamide version included in delivery / surcharge applied for brass nickel plated version Ex Approvals Special tool to turn the junction box (not included in delivery) Photo Description Photo Description Certification Identification Item no Drawing Brass. nickelplated, 6-13 mm PTB 04 ATEX 11 X, IECEx PTB 13.0027X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68, 773 278 TL 29-37 mm L 6 mm D 20 SW mm E 27 mm TL 36-45 mm Polyamide, 7-13 mm PTB 13 ATEX 1015 X, IECEx PTB 13.0034X II 2 G Ex e IIC Gb, II 2 D Ex tb IIIC Db IP68 773 277 L 10 mm D 20 SW mm E 28 mm Set SC02-AC10 Special wrench Service Manual 293 488 S. 33/37

6519 for extended temperature range Dimensions [mm] Threaded port version WWH D E A A 4.3 66 B 48 5.5 G1/4 H 30 50 G1/4 Threaded port version WWH Impulse, WWL, WWN D E A A 4.3 66 B H 48 G1/4 5.5 G1/4 30 50 WWH Version Variants A B D E H Stainless steel Standard, Ex m Ex i Standard, Ex m Ex i Standard, Ex m Ex i 53.5 107 35 40.7 45 51 177.8 186.6 WWH Aluminium 43.5 97 35 40.7 45 51 167.8 176.6 WWH Impulse, WWL, WWN Stainless steel 53.5 107 35 40.7 45 51 8.6 266.2 WWH Impulse, WWL, WWN Aluminium 53.5 107 35 40.7 45 51 148.6 266.2 S. 34/37

6519 for extended temperature range Dimensions [mm] NAMUR version WWC D E C A B G1/4 44 H 25 44.35 40 NAMUR version WWH D E Variant: stainless steel Variant: aluminium A B 44 C 44 C H G1/4 G1/4 44.35 25 40 10 14.5.5 WWC Version Variants A B C D E H Stainless steel Standard, Ex m Ex i Standard, Ex m Ex i Standard, Ex m Ex i 35 94 25 35 40.7 45 51 165 173.8 WWC Aluminium 25 84 15 35 40.7 45 51 155 163.8 WWH Stainless steel 35 94 47 35 40.7 45 51 165 173.8 WWH Aluminium 25 84 37 35 40.7 45 51 155 163.8 WWH Impulse, WWL, WWN Stainless steel 35 94 47 35 40.7 45 51 236 253.6 WWH Impulse, WWL, WWN Aluminium 35 94 47 35 40.7 45 51 236 253.6 S. 35/37

6519 for extended temperature range Dimensions [mm] NAMUR version WWH Impulse, D WWL, WWN E Variant: stainless steel Variant: aluminium 40 25 A 64.8 B H G1/4 44 G1/4 10 14.5 C 44.5 C 44.35 WWC Version Variants A B C D E H Stainless steel Standard, Ex m Ex i Standard, Ex m Ex i Standard, Ex m Ex i 35 94 25 35 40.7 45 51 165 173.8 WWC Aluminium 25 84 15 35 40.7 45 51 155 163.8 WWH Stainless steel 35 94 47 35 40.7 45 51 165 173.8 WWH Aluminium 25 84 37 35 40.7 45 51 155 163.8 WWH Impulse, WWL, WWN Stainless steel 35 94 47 35 40.7 45 51 236 253.6 WWH Impulse, WWL, WWN Aluminium 35 94 47 35 40.7 45 51 236 253.6 S. 36/37

6519 for extended temperature range Dimensions - Atex Approvals [mm] Cable coil Length acc. to ordering information D C 6.2 B A min R25 Junction box 68 27 F E M20x1.5 B R84 Turning radius 84.3 41.3 29.7 A Coil size A B C D E F 5 20.5 46 68.8 99.8 174.7 6 40 23.5 52 74.8 102.8 177.7 To find your nearest Bürkert facility, click on the orange box www.burkert.com In case of special application conditions, please consult for advice. We reserve the right to make technical changes without notice. Christian Bürkert GmbH & Co. KG 1606/13_EU-en_00891764 S. 37/37