Product Information Sheet

Similar documents
Product Information Sheet

Fire Barrier Duct Wrap 15A

Tremco Fire Protection Systems Group Technical Bulletin

Fire Barriers & Fire Stopping

4 Installation Requirements

Fiberglas, Exterior Wall Thermal Insulation

Services Enclosures and Protected Shafts - Maintaining Compartmentation

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

FIRESTOPPING & SMOKE SEALS

Guidelines for Earthquake Bracing of Residential Water Heaters

The Source of Firestop Expertise SM

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

EcoTouch Insulation with PureFiber Technology

FIRE AND SMOKE PROTECTION FEATURES

Terms and Definitions In Canada

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

Guidelines for Earthquake Bracing Residential Water Heaters

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

PART 1 GENERAL 1.1 SECTION INCLUDES

H-Stud Area Separation Wall System

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Excerpts from the Canadian National Building Code (NBC)

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

FIRE AND SMOKE PROTECTION FEATURES

GreenGuard Housewrap Installation Guide

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

GYPSUM AREA SEPARATION FIREWALLS GA

GUIDELINE ON THROUGH-PENETRATION FIRESTOPPING

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

Complete Firestop Systems Guide

Catalog Number Pillow Type Pillow Size

FIRE-RESISTANCE-RATED CONSTRUCTION

Policy on Water Heater Installations Policy No. UPC Effective: September 1, 1995 Revised: February 10, 1996

FRP AQUATIC DUCTWORK COMPONENTS LEADERS IN FIBERGLASS REINFORCED PLASTIC DUCT PRODUCTS

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

FINAL December 2012 SECTION DUCTWORK

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Re-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Passive Fire Protection

SECTION STANDING SEAM METAL ROOF

Chapter 3 Pre-Installation, Foundations and Piers

The Case for Cross Laminated Timber: Part 2

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

FIRE-RESISTANCE-RATED CONSTRUCTION

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

How To Make A House Safe

Roof Curbs, Extensions and Equipment Supports

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Preformed Metal Roofing and Siding

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

CertainTeed. Shaftliner For A rea Separation Firewalls

Underwriters Laboratories Testing Information

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

Built to Last. Built for Beauty. Good. Solid. Logix. TM

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

CHAPTER 6 DUCT SYSTEMS

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

DUCT SYSTEMS CHAPTER 6

SIMPLE SAVER SYSTEM DESIGN MANUAL

Rockwool Cladding Roll

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

PANELIZED HOME INSTALLATION GUIDELINE

FIRE DAMPER APPLICATION GUIDE

2014 British Columbia Building Code Changes

Eggers meticulously-crafted door frames are rivaled only by their beauty, quality and lasting performance. Turning nature s beauty into works of art

security products metric sizes Redefine your comfort zone.

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Dock Hardware & Accessory Products Catalog

Gridstone Gypsum Ceiling Panels

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Product Guide Specification

Residential Deck Safety, Construction, and Repair

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Transcription:

Distributed by Thermal Products Company, Inc. Product Information Sheet FyreWrap Elite 1.5 Duct Insulation Air Distribution System (ADS Ducts) Introduction Unifrax s FyreWrap Elite 1.5 Duct Insulation is a singlelayer flexible duct wrap enclosure for 1- and 2-hour fire-rated air distribution systems (ADS ducts). Typical duct types include smoke control, stairwell and vestibule pressurization, ventilation, supply/return ducts, commercial dryer exhaust, as well as refuse and linen chutes. This slim, compact design is an alternate to code prescribed fire-rated shafts and results in significant weight, space and labor savings when compared to traditional shafts. FyreWrap Elite 1.5 Duct Insulation Air Distribution System (ADS) offers the following features: 1- and 2-hour fire-rated enclosure Alternate to fire-rated shaft Zero clearance to combustibles at all locations on blanket wrap Saves weight, space, labor Thin, lightweight single-layer system High-temperature, biosoluble insulation Durable foil-scrim covering GREENGUARD listed for Microbial Resistance Typical Product Parameters Thickness 1.5" Nominal Density 6pcf Standard Product Form Scrim Encapsulated Product Availability 1.5" x 24" x 25LF 1.5" x 48" x 25LF Product Components Core Material: FyreWrap Elite 1.5 Duct Insulation incorporates Insulfrax Thermal Insulation as its core material. Insulfrax is a high-temperature insulation made from calcia, magnesia, silica chemistry designed to enhance biosolubility. It provides excellent insulation in a noncombustible blanket form. Encapsulating Material: The core insulation is completely encapsulated in an aluminum foil, fiberglass-reinforced scrim covering. This scrim provides additional handling strength as well as protection from tearing and moisture absorption. Complies with: IBC 2006 Sect. 909.10.2; IMC 2006 Sect. 513.10.2, NFPA 92A 2006 Sect. 6.62, NFPA 92B 2005 Sect. 7.5.2, NFPA 101 2006 Sect. 8.6.7, 18.7.7 FyreWrap Elite 1.5 Duct Insulation Typical Product Properties Intertek Testing Services File No. 14870 Design Listings Duct System: UNI/FRD 120-15 Fire Endurance Rating Stability Integrity Insulation ISO 6944 Type A Duct 2 Hours 2 Hours 2 Hours Firestop Test F-rating = 2 hrs., T-rating = 2 hrs. Per ASTM E 814, E 119 Firestop System: UNI/FRD 120-21, UNI/FRD 120-23, UNI/FRD 120-24, UNI/PHV 120-03, UNI/PHV 120-04 ASTM E 84/UL723 UL File No. R14514 Unfaced Blanket Encapsulated Flame Spread Rating: 0 < 25 Smoke Developed Rating: 0 < 50 ASTM E 136 Non-combustibility ASTM C 411 Hot Surface Performance Pass Pass ASTM C 518 Durability Pass; R-Value = 4.8 per inch @ 75 F ASTM C 518 Thermal R-Value of Elite 1.5 (1 1 2") = 7.2 Resistance ASTM E 90 ASTM D 6329-03 Microbial Resistance Sound Transmission Class STC = 31 db Resistant to Mold Growth California State Fire No: 240-1478:100 Marshal Listing New York City Building Bulletin 2009-028 Listed

Installation FyreWrap Elite 1.5 Duct Insulation ADS System consists of a single-layer applied directly on to the duct surface. Only encapsulated blanket should be utilized to ensure the outer surface of the insulation is protected. The insulation system may be installed at zero clearance to combustibles at all locations on the wrap at material overlaps and in the field between overlaps. To minimize waste, FyreWrap Elite 1.5 should be rolled out tautly before measuring and making any material cuts. Install insulation with a 3" minimum overlap on all joints. Seal cut edges with pressure-sensitive aluminum foil tape. The perimeter transverse overlap of adjacent blanket may be installed using any of the following three techniques. See Figure 1 for details. Telescope Overlap Wrap Technique This wrap technique is the most common method of installing FyreWrap Elite 1.5 where each adjacent blanket has one edge exposed and one edge covered by the next blanket, to form a 3" overlap. Checkerboard Overlap Wrap Technique This installation uses a 3" overlap pattern with both edges of each alternating blanket covered by each adjacent blanket whose edges are exposed. The overlap joints in alternate layers of blanket resemble a checkerboard pattern in the completed installation. This technique is often utilized when a small section of duct wrap must be repaired. Butt Splice with Collar Wrap Technique This wrap technique permits installation with the blanket edges butted together and a 6" wide collar of blanket that is centered over the butt splice, overlapping each adjacent blanket 3". The collar can be field fabricated from FyreWrap Elite 1.5 rolls or purchased separately. Attachment Option Banding Only Duct Width < 24" FyreWrap Elite 1.5 Duct Insulation Single Layer Air Distribution System (ADS) 1- and 2-Hour Fire-Rated Enclosure FP-455 Telescoping Overlap Technique Cross-Section View 1 FyreWrap Elite 1.5 Duct Insulation, One Layer 2 Filament Tape (Temporary Hold) 3 Carbon Steel Banding Straps (Permanent Hold) 4 3" Minimum Longitudinal Overlap 5 3" Minimum Perimeter Overlap 6 Minimum 26 ga. Air Duct Checkerboard Technique Cross-Section View Butt Joint & Collar Technique Cross-Section View Attachment Option Banding and Pins Duct Width up to 24" x 48" Pins required on bottom/backside only, spaced max. 12" rows and on 10 1 / 2" centers (not shown) Attachment Option Pins Only Any Duct Width (Mandatory for Duct widths > 48") 1 FyreWrap Elite 1.5 Duct Insulation, One Layer 2 Filament Tape (Temporary Hold) 3 Carbon Steel Banding Straps (Permanent Hold) 4 3" Minimum Longitudinal Overlap 5 3" Minimum Perimeter Overlap 6 Minimum 26 ga. Air Duct 1 FyreWrap Elite 1.5 Duct Insulation, One Layer 2 Weld Pin pre-welded or cup head 3 Speed Clip 4 3" Minimum Longitudinal Overlap 5 3" Minimum Perimeter Overlap 6 Minimum 26 ga. Air Duct Figure 1. FyreWrap Elite 1.5 Duct Installation ADS System Installation Techniques Page 2 of 6

Attachment Options Three attachment options are available for installers. The choices are limited by the duct width dimension. Details on each are provided below and shown in Figure 1. Banding Only: For Duct Widths 24" or Less To temporarily secure the insulation, optional use of filament tape is permitted. Place carbon steel or stainless steel bands (min. 1 2" wide, nom. 0.015" thick) over material joints and within the field between. Locate bands 1 1 2" from the edge of each blanket overlap. Place an additional band(s) between overlaps, spaced 10 1 2" on center. Tighten banding to firmly hold the wrap system in place but not so tight as to cut or damage the blanket and secure with minimum 1" long steel crimp clips. Pins are NOT required when the duct size falls within the above dimensions and this banding technique is used. Banding and Pins: For Duct Widths 48" Weld 12-gauge steel insulation pins to the underside of horizontal runs and backside (side of duct having largest dimension) of vertical duct runs. Place pins at maximum 12" rows and on maximum 10 1 2" centers. To temporarily secure the insulation, optional use of filament tape is permitted. Impale FyreWrap Elite 1.5 over the pins and secure with 2 1 2" square or 1 1 2" round galvanized steel speed clips (washers). Turn down or cut off exposed ends of pins to eliminate safety hazards. Locate carbon steel or stainless steel bands (min. 1 2" wide, nom. 0.015" thick) 1 1 2" from the edge of each overlap joint. Locate an additional band(s) between overlaps, spaced 10 1 2" on center. Tighten banding to firmly hold the wrap system in place but not so tight as to cut or damage the blanket and secure with minimum 1" long steel crimp clips. Cup head style pins are also permitted and shall be located at the same spacing as pre-welded pins. Pins Only: For Duct Widths > 48" Weld 12-gauge steel insulation pins on all sides of the duct. Place insulation pins at maximum 12" rows and on maximum 10 1 2" centers. Pins in each row are maximum 6" from each duct edge. Locate insulation overlaps so they are centered on the pins. Impale FyreWrap Elite 1.5 over the pins and hold in place with 2 1 2" square or 1 1 2" round galvanized steel speed clips (washers) to keep the blanket from sagging. Turn down or cut off exposed ends of pins to eliminate safety hazards. Cup head style pins are also permitted and shall be located at the same spacing as pre-welded pins. The pins only attachment method can be used for duct widths less than 48", but is optional. Supports The duct support system shall be designed as required by IMC or SMACNA requirements and that will support the load of the ventilation air duct and the additional weight of the FyreWrap Elite 1.5 Duct Insulation ADS System under a fire load. Attachment Options (Summary Chart): Banding Banding & Pins Pins Only Duct Dimension Only (Pins on Bottom) (All Four Sides) Width 24" Width 48" Width > 48" Firestop Systems Where ducts insulated with FyreWrap Elite 1.5 pass through fire-rated walls and floors, the penetration opening shall be firestopped to maintain the fire rating of the assembly. Firestop systems tested per ASTM E 119 and ASTM E 814 are provided below. Additional Tested and Listed firestop systems may be available for use. For details and assistance, contact Unifrax at 716-278-3800 and ask for Fire Protection Application Engineering, or search the test laboratory web site directly for the latest documentation. Page 3 of 6

2 FyreWrap Elite 1.5 Duct Insulation Through Penetration Firestop Systems Intertek Design Nos. UNI/FRD 120-21, UNI/FRD 120-23, UNI/FRD 120-24 Per ISO 6944, ASTM E 814, ASTM E 119 F-Rating = 2 hours,.t-rating = 2 hours 4 4 5 5 3 1 3 6 8 6 7 7 2 5 3 1 4 FP-495 1 Concrete Floor Assembly, 4 1 2" depth. 2 Air duct, min. 26 gauge, 1296 in 2 area, max. 54" width. 3 FyreWrap Elite 1.5 Duct Insulation, One Layer. 4 Unfaced FyreWrap Elite 1.5 Blanket, 4 1 4" depth. Compressed 33%. 5 STI SpecSeal SSS, 1 4". Plus 3 4" Overlap On Concrete and duct insulation. 6 Annular Space, 1" to 2". 7 Duct Reinforcement: 1 8" thk. steel angle (1" tall vertical leg x horizontal leg dim. at least equal to width of annular space). Attach using 1 4" dia. steel pop-rivets. Spaced max 6" O.C. OR 8 Min. 1 8" thk. steel plate over the firestop sealant (compressing ductwrap 1 4" and extending onto floor surface 2"). Attach with 1 4" dia. concrete screws, spaced 6" O.C. Figure 2. FyreWrap Elite 1.5 Duct Insulation Through Penetration Wall Systems Intertek (OPL) Design No. UNI/PHV 120-03, UNI/PHV 120-04 ASTM E 814: F-Rating = 2 hours, T-Rating = 2 hours FP-627 1 Air Duct, min. 26 gauge, 1296 in 2 area, 54" max. width 2 FyreWrap Elite 1.5 Duct Insulation, One Layer 3 Unfaced FyreWrap Elite (Compressed 33%>, recessed 1 2" on each side) 4 Firestop Sealant, 1 2" depth, overlapping on gypsum board and duct min. 1" 3M Fire Barrier 1000NS or Hilti FS-ONE or STI SpecSeal SSS or Tremco FyreSil 5 Gypsum Wallboard Assembly, 2 Hr. rated 6 Annular space, 1" to 1 1 2" 7 Duct Reinforcement, 1" x 1" x 1 8" steel angle on all four sides of duct and located on both sides of wall Figure 3. Page 4 of 6

FyreWrap products offer solutions in applications such as: Grease, Air Ducts Railroad Tank Cars Cable Trays, Conduits Transit Cars Control System Covers Ships Above Ground Storage Tanks Expansion Joints Marine Bulkheads, Decks Fire Door Seals Structural Steel Chimney Liners Construction Joints Ceiling Air Diffusers Curtain Walls/Safing Hazardous Material Circuit Protection Storage Containers Unifrax has a wide range of FyreWrap fire protection materials available to provide passive fire protection solutions in a variety of applications in the commercial building, industrial facility and transportation industries. For additional information about product performance or to identify the recommended product for your fire protection application, please contact Unifrax at 716-278-3800 and ask for Fire Protection Application Engineering. Data are average results of tests conducted under standard procedures and are subject to variation. Results should not be used for specification purposes. Refer to the product Material Safety Data Sheet (MSDS) for recommended work practices and other product safety information. Page 5 of 6

2011, Unifrax I LLC Page 6 of 6 The following are registered trademarks of Unifrax: FyreWrap, Elite, and Insulfrax. The test data shown are average results of tests conducted under standard procedures and are subject to variation. Results should not be used for specification purposes. Product Information Sheets are periodically updated by Unifrax. Before relying on any data or other information in this Product Information Sheet, you should confirm that it is still current and has not been superseded. A Product Information Sheet that has been superseded may contain incorrect, obsolete and/or irrelevant data and other information. Thermal Products Company, Inc. 4520 S. Berkeley Lake Rd. Norcross, GA 30071-1639 Phone: 770-662-0456 Fax: 770-242-6210 www.thermalproductsco.com info@thermalproductsco.com