BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS.



Similar documents
Including. Rubershield-Pro. Breather Membrane

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

ROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS

Roofers Guide to Underslating Membranes

Multi-layer Insulation Blanket for Roofs

PROVIDING PROTECTION IN CONSTRUCTION Technical guide: roofs.

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN

AND MEMBRANES ROOFING UNDERLAYS.

MONARPERM 600, MONARPERM PLUS AND MONARPERM TOP (COLD VENTILATED AND WARM NON-VENTILATED)

Rochdale Building Control Guide. Approved Document C. Site preparation and resistance to contaminants and moisture

Asphalt Shingle Application Requirements

Western Red Cedar Shingles Product Guide

BUILDING CONTROL GUIDANCE SHEET SMOKE ALARMS IN STANDARD DWELLINGS Last updated 16/12/2010

I n s u l a t i o n. Low Energy Low Carbon Buildings

Preventing Ice Dams on Roofs

Introduction & Principles Issued in support of Junction Details, Parts 1 to 5

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Technology at its best. Benefits

ROOFS, SNOW AND ICE DAMS

When considering Roof drainage design the following should be taken into account:

FUNCTIONAL REQUIREMENTS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Cupa Natural Slate Roofing design and fixing guide

THE REDLAND GUIDE TO BS 5534

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

Dealing with damp and mould growth

2014 British Columbia Building Code Changes

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Energy Company Obligation (ECO): Technical Monitoring Questions

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

TP10. Insulation RAFTER LEVEL INSULATION FOR TILED OR SLATED PITCHED WARM ROOF SPACES BBA BRITISH

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Section Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

INSULATED PITCHED ROOFING

Ubiflex. Non-lead flashing system

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Bituminous Sheet Flat Roofs: Their repair and maintenance

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

SHINGLE APPLICATION GUIDE

State of Connecticut Department of Public Health RADON PROGRAM

Building Regulations for the Conservation of Fuel and Power

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Manual lifting and handling

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Guide to the safe installation of downlighters in dwellings

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Residential Roofing Guide

Asbestos in the home. for you - for your community - not for profit

Cl/SfB (13.9) a comprehensive. technical guide. to the specification of. vapour control layers. GROUP LTD

September September Consulting Structural and Civil Engineers. 100 St John Street London EC1M 4EH. akt-uk.com

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Chapter 2 Basis of design and materials

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

Housing Services Guidance for tackling condensation, damp and mould in your home

The formation of roof waterproofing details calls for

Under Tile and Slate Undersheeting System

Rain Penetration Tests on Manthorpe Mini Castellated Vent Tile with 15" x 9" Format Roof Tiles. Prepared for: Ben Hales

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Shingle Roofing: What s below the surface is important

Making Your Home Ready For Solar Water Heating

Dealing with damp, condensation and mould growth in your home.

SANS FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/ / / /341

Water Damage & Repair

Providing protection in construction

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Housing Fact Sheets. Moisture Condensation at the Windows

Condensation. Some Causes, Some Advice

Regulatory Services. Asbestos in the Home. What is asbestos?

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Mark Cramer Inspection Services, Inc.

WATERPROOFING FOR CONCRETE STRUCTURES

Vapor Permeability Provides No Performance Benefit for in Ventilated Attics

Building Control Guidance Note

CI/SfB (4-) Rf9 January Dry fix and ventilation systems including UNIVERSAL accessories. Roofing product catalogue 45

Triflex system: Triflex ProDetail. Solution type: Roof detail and repair waterproofing. Application: Overlay of existing substrate

Monarflex Vapour Control Layers

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

ABSeam Panel Overview and Installation Instructions

Chapter 9: INSTALLING ROOFING

Signs of insulation problems In the winter. In the summer. conditioning system

Shingle Installation Guide

CONDENSATION IN REFRIDGERATED BUILDINGS

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

TR21. I n s u l a t i o n. Low Energy Low Carbon Buildings

The HardieZone System: HZ10 Care and Maintenance Guide

Part 7 Roofs. Chapter 7.2. Pitched roofs. Effective from 1 January 2012

about your house Before You Start Renovating Your Basement Moisture Problems Figure 1 Moisture problems to solve

DENSO WATERPROOFING SYSTEMS

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

Transcription:

Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET USE OF BREATHABLE ROOFING FELTS. Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance Note is for the benefit of local architects, builders and the general public. Its purpose is to provide information, promote good practice and encourage consistency of interpretation for all. It is purely advisory in nature and does not cover every aspect of the topic concerned, but tries to cover the main, commonly encountered points. If more details are required then the relevant Approved Documents, British Standards or manufacturers instructions should be consulted. The Guidance Note is not intended to outline the only way of carrying out the type of work referred to. If in doubt, please contact your local Building Control Authority. This document should not be submitted as part of any Building Control application. The Council offers a complete Building Control service, from pre application advice on technical aspects and how to make an application, through to plan checking and an inspection regime to ensure a safe and compliant building. We also offer an Energy Performance Assessment service which uses SAP methodology to produce Energy Performance Certificates (EPC s) in respect of new and existing buildings. Please contact Building Control for any further information: Building Control Contact Details: General enquiries: Tel: 01509 634757 01509 634924 01509 634749 (24 hour answer machine) Fax: 01509 260536 Email: building.control@charnwood.gov.uk Web: www.charnwood.gov.uk/pages/buildingcontrol1 Further information can be obtained from The Building Regulations 2010 or from the Council s Building Control Service on request. The views expressed in this document are those of Charnwood Borough Council and do not necessarily represent a guaranteed methodology for compliance with the requirements of the Building Regulations 2010. Charnwood Borough Council accepts no liability for any claim that may arise in relation to reliance on the information contained in this document.

1.0 INTRODUCTION 1.1 This document applies to dwellings with a cold or warm roof of traditional construction. This does not apply to where a breathable membrane is used with cladding. 1.2 Please read all of the questions below. 1.3 Breathable roofing membrane has been used in building for many years now and, more recently, in cold pitch roof construction without traditional eaves ventilation. The benefit of reduced heat loss and not having to incorporate ventilators has seen their use grow but at the same time has attracted noticeable comment both from supporters of the application and from detractors who favour traditional ventilation solutions. 2.0 TYPES OF BREATHABLE MEMBRANES ARE DEFINED AS FOLLOWS, 2.1 Breathable membranes have a water vapour resistance of less than or equal to 0.6MN.s/g a) High water vapour resistance membrane (type HR) has a water vapour resistance greater than to 0.25MN.s/g b) Low water vapour resistance membrane (type LR) has a water vapour resistance less than 0.25MN.s/g c) This document applies to type LR only - in light of this the following document has been prepared to try to answer some of the common questions raised regarding using this type of construction. 3.0 WHAT IS A ROOFING MEMBRANE AND HOW DOES IT WORK? 3.1 The particular membrane in question is typically a micro porous membrane which has a structure sufficiently fine to prevent liquid water penetration in service conditions, but not too fine to prevent water vapour (molecules of water in air) penetration. 3.2 All materials, including vapour control layers, have a finite permeability to water vapour transfer. 3.3 However, in the context of this article, a breathable roofing membrane is a material which, in service conditions, is sufficiently permeable to water vapour transfer to adequately limit the risk of condensation in roofs. 3.4 The function of these membranes is to provide all of the normal demands made on a roof underlay and at the same time allow water vapour egress without making specific provision for ventilation. 4.0 WHEN DO I NEED TO PROVIDE VENTILATION TO A ROOF FITTED WITH A BREATHABLE MEMBRANE? 4.1 It is often wrongly assumed that the breathable membrane is a straightforward replacement for the sarking or more traditional roofing felt normally used to the roof structure and once fitted there is no need to ventilate the roof space. 2

4.2 As a general rule of thumb however it will be necessary to provide ventilation to a roof void fitted with breathable felt under the following circumstances, a) The breathable membrane is fitted tight across the rafters and no counter battens are fitted. b) The new roof fitted with the breathable membrane is linked to an existing roof fitted with traditional felt or the extension results in a combination of different breathable membranes being used. c) The new roof fitted with the breathable membrane is linked to an existing roof which is already vented. d) The building does not fully comply with the requirements of Approved Document F, ventilation or BS5250, Control of condensation in buildings. e) Tight fitting slates and tiles are used. f) Where it is recommended by the manufacturers or where the BBA certificates requires ventilation. Some breathable felt manufacturers recommend ventilation at ridge level. g) BBA or BRE certificates not complied with fully 5.0 CAN THE ROOFING MEMBRANE BE USED SIMPLY INSTEAD OF CONVENTIONAL EAVES VENTILATION? 5.1 Only if a number of measures are taken to limit the ingress of water vapour into the unvented space. In this regard, the roof system must be considered in its entirety, from ceiling to roof tiles, including the following design points:- a) All penetrations into the roof space must be properly sealed b) Loft hatches must incorporate effective compressible draught seals c) The rooms below the ceiling must include provision for the dispersal and rapid dilution of water vapour in accordance with the Building Regulations, including extractor fans in rooms that may experience high humidity d) All water tanks n the loft space must be covered e) Any vent pipes should be arranged so that they do not discharge water vapour into the loft space. f) Cavities closed at plate level to stop vapour transfer to roof space. g) Where it is proposed to install spotlights/down lighters always refer to the relevant BBA/BRE certificate for guidance. h) Always check the BBA for the felt to be used to check suitability and how to install in your roof design. 6.0 WHAT ARE THE ADVANTAGES OF USING THE ROOFING MEMBRANE UNVENTED SYSTEM? 6.1 One of the main advantages is reducing the amount of heat lost by air leakage through the ceiling and from the loft space to the outside. Up to 25% of the heat lost through a conventional roof system is by this mechanism. 6.2 The unvented roof system will reduce this mechanism of heat loss, more so if the underlay laps are sealed. In addition, not having to provide eaves and ridge ventilation can help to save time and cost on site and can give more desirable appearance to the finished roof? 3

7.0 WHAT ARE THE DISADVANTAGES OF USING THE ROOFING MEMBRANE SYSTEM? 7.1 Extra time and care is needed to ensure that penetrations into the ceiling are properly sealed and that the loft space is protected from sources of water vapour, in accordance with the requirements of the certificate. 7.2 If the ceiling is constructed without due attention to sealing joints and around penetrations, the opportunity for moisture ingress into the loft space and consequent risk of condensation occurring is increased, this is also true of conventionally ventilated constructions where the effect of wind movement over the roof can reduce the air pressure in the loft space and suck moisture laden warm air from living space into the loft space. 7.3 However, it is recognised that the rate of moisture removal via the ventilated and unventilated approach is not the same. It is therefore important that the ceiling is sealed to an appropriate level. 7.4 Where the membrane is draped between rafters there have been reports of flappingnoise in roofs incorporating some types of permeable roofing membranes in certain wind conditions. In a worst case scenario this could result in tiles lifting off the roof surface. 8.0 HOW DURABLE ARE ROOFING MEMBRANE SYSTEMS? 8.1 In normal conditions found in roofs, the membranes are durable and can be expected to have a life comparable to that of traditional roof tile underlay. Specifiers should however follow the requirements of the relevant Certificate relating to the period for which the underlay can be exposed to the elements before slating/tiling and on the use of eaves guards for open eaves construction. 8.2 With regard to water vapour permeability, the BBA assessment included measurements of the effect of heat ageing; effect of UV light exposure and of accelerated dust/debris accumulation and found no discernible reduction in performance. 9.0 DO I NEED A VAPOUR CHECK CEILING? 9.1 Not always but it can help. Most manufacturers recommend a vapour control layer be fitted over bathrooms, utility rooms and kitchens. It is important to remember that vapour will pass through the path of least resistance in a ceiling. Gaps and cracks will provide an effective short cut however high the vapour resistance of the rest of the ceiling is. 9.2 We would always recommend that a vapour barrier be installed. This is of particular importance where there are sloping ceilings and/or engineered joists within the roof construction. 10.0 WHAT DO I DO ABOUT SOURCES OF MOISTURE IN THE LOFT? 10.1 Water tanks should have lids on and vent pipes arranged to avoid venting moisture into the loft space. 4

11.0 DO I NEED TO COUNTER BATTEN? 11.1 In general, counter battens are not required if the underlay is draped between rafters, i.e. a nominal 10mm. If however it is not draped but pulled taut, counter battens are required. Please refer to specific Certificates for the holders detailed installation instructions. The drape or counter battens are there to allow water vapour to disperse or drain away 12.0 DOES THE ROOFING MEMBRANE HAVE TO RUN PARALLEL TO EAVES OR PERPENDICULAR (eaves to ridge)? 12.1 Traditionally, roof tile underlays are laid in runs parallel to the eaves with subsequent runs weather lapped by 150mm. Some Certificate holders have had an alternative approach also assessed, where the underlay is drawn from the eaves, over the ridge down to the eaves on the opposite side of the building. This entails the use of a device to hold the roll of underlay horizontally and allows it to be unwound. 12.2Due to safety issues the eaves/ridge/eaves method is rarely used. Counter battens are needed to secure laps between adjacent runs of underlay. Users should refer to the relevant Agreement Certificate for full details of this alternative method of installation. 13.0 WHAT TYPE OF ROOFING BREATHABLE FELT COVERING CAN BE USED? 13.1 The issued Certificates cover conventional slates and tiles installed to the relevant clauses of BS 5534-1: 2003, Code of practice for slating and tiling (including shingles). Some tightly fitting tiles and slates need special consideration and designers should check with the tile or slate manufacturer in case they have particular design requirements, for example a ventilation space beneath them. 14.0 WHAT HAPPENS TO CONSTRUCTION MOISTURE? (Water added during the construction process) 14.1 The amount of construction moisture in a new building depends on the materials used and type of construction. The risk of condensation is however greatest when there is a significant drying out taking place and cold temperatures. 14.2 This may in some circumstances lead to condensation during the first heating season, but should not persist into the second heating season in a properly designed and constructed roof. 14.3 BS5250, Code of practice for the control of condensation in buildings, states you can use a 5mm ridge vent to help improve moisture removal. 15.0 WHAT IS THE DIFFERENCE BETWEEN A NON-VENTILATED SYSTEM AND A SEALED SYSTEM? 15.1 Both systems are non-ventilated but the sealed system includes adhesive tape at all laps in the membrane, penetrations and edge details. Not all membranes are required to be sealed. Seals are normally specified where maximum thermal efficiency is required. 5

16.0 CAN BREATHABLE MEMBRANES BE DRESSED INTO THE GUTTER? 16.1 No, It is generally accepted as good practice for all roofing underlays to be stopped short of the gutter, overlapping a proprietary eaves protective device (BS5534) this is normally a UV (sunlight) resistant eaves sheet such as an eaves carrier or dpc felt that replaces the underlay as a drip into the gutter. 16.2 The roofing underlay should not be left permanently exposed to direct sunlight. 17.0 CAN BREATHABLE MEMBRANES BE LEFT EXPOSED TEMPORARILY BEFORE SLATES/TILES ARE FITTED? 17.1 Yes. The ultra violet stability of the membrane allows them to be left exposed for a period before being covered. This can be up to four months but check with manufacturer to confirm exact limit for the membrane specified. 18.0 CAN I USE THE BREATHABLE ROOFING MEMBRANE ON VERTICAL CLADDING? 18.1 No, there is a difference in the requirement and the membrane manufacturer should be consulted for further advice. NOTE: Before any final decision is made with roof design and breathable membrane specification always contact the manufacturer s technical service department for clarification. DOCUMENTS REFERRED TO BS 5534-1 2003, Code of practice for slating and tiling (including shingle) BS5250, Code of practice for the control co condensation in buildings Building Regulations Approved Document F USEFUL LINKS http://www.bbacerts.co.uk http://construction.tyvek.co.uk http://www.proctorgroup.com/products/condensationcontrol.aspx 6