roline Commercial Drainage Products Catalog & Price List Effective April 2, 2012 watts.com

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

SECTION STORM DRAINAGE SYSTEM

frostdrainage.com Floor Drains & Rodding Eyes

MIFAB Floor Drain Selection Guide

Plugging Home Drains to Prevent Sewage Backup

Fabricated Drainage Products

SECTION DUCTILE IRON PIPE AND FITTINGS

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

BOQ for Plumbing, Sanitary Works

SECTION DUCTILE IRON PIPE AND FITTINGS

SECTION STORM DRAIN SYSTEM

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Packaged Terminal Air Conditioner Wall Sleeve Installation

CHAPTER 11 STORM DRAINAGE

SECTION POLYVINYL CHLORIDE (PVC) PIPE

Welcome: What is U Drain? Drain Materials. Flow

INDEX. Sec. No. Items Page Nos.

2006 Codes. Please verify the following before calling for inspection

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

CITY OF NORTH RIDGEVILLE 7307 AVON BELDEN ROAD NORTH RIDGEVILLE, OH (440)

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

State of Connecticut Department of Public Health RADON PROGRAM

CHAPTER 11 STORM DRAINAGE

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED

Ver. 2. Guide to. Inspecting Residential Brick Veneer

8.7 Schluter -KERDI-LINE

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

SECTION FACILITY STORM DRAINAGE PIPING

WATER & SEWER CORROSIVE RESISTANT PRODUCTS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PLUMBING SPECIALTIES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

CODE GUIDE 302 and Glossary of Industry Terms

foundation designed to keep water out of the basement.

Telescoping Post Indicator Wall Post KENNEDY VALVE ISO 9000 ISO 14001

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

8.2 Schluter -KERDI-DRAIN

Chapter 3 Pre-Installation, Foundations and Piers

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Access Hatch Solutions

SECTION ASBESTOS CEMENT PIPE REPAIRS, DEMOLITION, AND DISPOSAL

PLUMBING ROUGH IN INSPECTION

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI

WATER SERVICE 2

Copper and Copper Alloy Tube, Pipe and Fittings

Access Hatch Solutions. ejco.com

Wastewater Capital Projects Management Standard Construction Specification

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

SECTION PIPE HANGERS AND SUPPORTS

Mitigating Basement Backups

SECTION STORM DRAINAGE TABLE OF CONTENTS

Technical Data. wedi Fundo Shower System Primo

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

CHAPTER 7 SANITARY DRAINAGE

Rehabilitation of an Aging Concrete Reservoir Adit Tower

How To Replace A Reverse Osmosis Water Tank

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Pipe Repair Products A complete selection for all types of pipe

Storm Drainage Structures

DESIGN AND CONSTRUCTION GUIDELINES AND STANDARDS DIVISION 33 UTILITIES SITE UTILITIES

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

INSTALLATION OF A BAY WINDOW

SECTION GROUND WATER STORAGE TANKS

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

American- Darling 5¼" B-84-B-5.

OPERATION AND MAINTENANCE MANUAL 5-1/4 B-84-B-5 FIRE HYDRANT

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

During severe flood events, such as those

Saferand easierinstallation

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Improving the flood resistance of your home. Advice sheet 6: Flood-resilient floors

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Preventing water damage in the basement

Arapahoe County Residential Water Heater Installation and Inspection Guide

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

Universal Installation and Maintenance Instructions Double Wall Spill Containment Bucket (5 and 15 gal)

SECTION FIRE HYDRANTS

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

NEW CONNECTION INDUSTRIAL PRODUCTS NC.10V NC.20V NC.30V. NC. SD.10 NC. SD.20 NC. F.Clamp

Ductile Iron Pipe Couplings

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Cellar Tech Containment Well Cellar Systems

Dock Hardware & Accessory Products Catalog

Transcription:

Pictorial Index Product Recommendations Floor Drain Selection Factors Load Rating Grate Free Area Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations FLOOR AND AREA DRAINS TABLE OF CONTENTS Distributed by: BEST MATERIALS LLC Phoenix AZ Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 Email: sales@bestmaterials.com www.bestmaterials.com S-WD-FD-1 0812

PICTORIAL INDEX FLOOR AND AREA DRAINS FD-100-A Round Strainer FD-100-EF Round Funnel FD-100-FT6 Recessed Tile Flange FD-100-RS Rectangular Strainer FD-100-AS Angle Strainer FD-100-EG Oval Funnel FD-100-K Dome Strainer FD-100-SO Side Outlet FD-100-B HD Round Strainer FD-100-ER Extended Rim Strainer FD-100-L HD Square Strainer FD-100-VD Solid Hinged Cover FD-100-DD Hub Funnel FD-100-FC Surface Membrane Clamp FD-100-M Square Strainer FD-100-VS Square Hinged Solid Cover S-WD-FD-2 0812

PICTORIAL INDEX FD-100-WD Domed Standpipe FD-200-DD Hub Funnel FD-200-FC Surface Membrane Clamp FD-200-M Square Strainer FD-200-A Round Strainer FD-200-EF Round Funnel FD-200-FT6 Recessed Tile Flange FD-200-RS Rectangular Strainer FD-200-AS Angle Strainer FD-200-EG Oval Funnel FD-200-K Dome Strainer FD-200-VD Solid Hinged Cover FD-200-B HD Round Strainer FD-200-ER Extended Rim Strainer FD-200-L HD Square Strainer FD-200-VS Square Hinged Solid Cover S-WD-FD-3 0812

PICTORIAL INDEX FD-200-WD Domed Standpipe FD-310 6-1/2" Fixed Top FD-320-Y-SET 8" Fixed Top FD-340-SET 12" Adj. Top FD-230-A Combination FD-320 8" Adj. Top FD-330 8x8" Adj. Top FD-340-Y 12" Fixed Top FD-240 Prison Cell FD-320-SET 8" Adj. Top FD-330-Y 8x8" Fixed Top FD-340-Y-SET 12" Fixed Top FD-300 6-1/2" Adj. Top FD-320-Y 8" Fixed Top FD-340 12" Adj. Top FD-360 15" Adj. Top S-WD-FD-4 0812

PICTORIAL INDEX FD-360-Y Area Drain with 15" Round Fixed Top FD-410 Catch Basin FD-460 12x12" Adj. Top FD-490-F-80 Parking Structure (Aluminum) FD-380 Adjustable Wood Floor Drain FD-430 Side Outlet FD-460-F 12x12" Fixed Top FD-520 Side Outlet Parking Area FD-390-E General Purpose FD-450 15x15" Adj. Top FD-470-F-1 Area Drain with Shallow Body Promenade Drain FD-530 Offset Parking Area FD-390-E-63 Wooden Floors FD-450-F 15x15" Square Fixed Top FD-490-F-4 Parking Structure FD-540 Parking Area S-WD-FD-5 0812

PICTORIAL INDEX FD-600 Unfinished Isolation FD-810 Iowa Garage Drain FD-870 12" Planting Area FD-920 Parking Deck Drain for Precast Slabs FD-620 Finished Isolation FD-820 Flushing Rim FD-900 12" Precast Parking Area FD-1100-A Round SS Strainer FD-660 PVC Area Drain FD-830 Hopper Drain FD-910 15" Precast Parking Area FD-1100-B HD Round SS Strainer FD-670 PVC Area Drain FD-860 8" Planting Area FD-920 Parking Deck Drain for Precast Slabs FD-1100-L HD Square SS Strainer S-WD-FD-6 0812

PICTORIAL INDEX FD-1100-M Square SS Strainer FD-1200-L HD Square SS Strainer FD-1160 Chemical Resistant FD-1200-M Square SS Strainer FD-1200-A Round SS Strainer FD-1200-B HD Round SS Strainer S-WD-FD-7 0812

Application PRODUCT RECOMMENDATIONS Product Basement Areas... FD-300, FD-310-Y, FD-320(-Y), FD-320(-Y)-SET Carwash & Sediment Collection Areas... FD-410 Clinical & Surgical Areas... FD-820 Condensate & Drip Lines (Indirect Waste)... FD-100-DD, FD-200-DD, FD-100-EF, FD-100-EG, FD-200-EF, FD-200-EG Elastomeric & Rubberized Floors... FD-100-FC, FD-100-FT6 Floating Slabs... FD-600, FD-620 Food Preparation Areas... FD-1100 Series, also see Sanitary Floor Sinks Garage & Service Bays... FD-430, FD-450(-F), FD-460(-F), also see Trench Drains Industrial & Warehouse Areas... FD-320(-Y), FD-330(-Y), FD-340(-Y), FD-460(-F) Interior Finished Areas... FD-100 Series, FD-200 Series Maintenance & Boiler Rooms... FD-320(-Y), FD-340(-Y), FD-360(-Y) Outdoor Parking Areas... FD-520, FD-530, FD-540, see also Trench Drains Outdoor Walkways... FD-340-1, FD-360-1, FD-450-1, FD-460-1 Planting Areas... FD-860, FD-870, FD-880 Poured Parking Decks... FD-490-F-4, FD-490-F-80 Precast Parking Decks... FD-900, FD-910, FD-920 Prison Cells... FD-240 Sanitary Manufacturing Areas... FD-1100 Series, FD-1200 Series Shower Areas... FD-100 Series, FD-1100 Series Stairwells... FD-100 Series, FD-200 Series Wood Floors... FD-380, FD-390 Distributed by: BEST MATERIALS LLC Phoenix AZ Ph: 800-474-7570, 602-272-8128 Fax: 602-272-8014 Email: sales@bestmaterials.com www.bestmaterials.com S-WD-FD-8 0812

Load Rating FLOOR AND AREA DRAINS FLOOR DRAIN SELECTION FACTORS Load ratings are based upon maximum anticipated traffic, in accordance with American National Standards ASME A112.21.1M. See specification pages for specific load rating data. Light Duty (LD) - Safe Live Load Under 2000 lbs. Medium Duty (MD) - Safe Live Load 2000-4999 lbs. Heavy Duty (HD) - Safe Live Load 5000-7499 lbs. Extra Heavy Duty (XHD) - Safe Live Load Between 7500 and 10,000 lbs. Special Duty (SD) - Safe Live Load Over 10,000 lbs. Grate Free Area Drains should be specified with sufficient grate free area and outlet size to pass anticipated flow. For most indoor applications, the grate free area should equal 1-1/2 times the transverse area of the connecting pipe. In exterior areas, the grate free area should be twice the transverse area of the connecting pipe. Recommended Free Areas Material & Characteristics Interior Exterior Pipe Transverse Free Area Free Area Size Sq. In. Sq. In. Sq. In. 2" 3.14 4.71 6.28 3" 7.06 10.59 14.12 4" 12.50 18.75 25.00 5" 19.60 29.40 39.20 6" 28.30 42.45 56.60 8" 50.25 75.38 100.50 Bodies - Industrial grade cast iron, finished with Watts standard gray acid resistant epoxy coating. Most Watts floor and area drains can be specified with PVC (-60) or ABS (-61) bodies, for direct solvent weld connection. Unfinished Areas - Watts standard epoxy coated ductile iron grates provide superior chemical and shock resistance compared to competitive enameled cast iron grates. Finished Areas - Nickel bronze (-1) has a silvery appearance which compliments most interior finishes. Watts nickel bronze alloy is homogenous, highly resistant to wear, and will not be discolored by weather or traffic. Adjustable Tops - Commonly specified, provide vertical adjustment of strainer head or top assembly to the level of the finished floor. Fixed Tops - Generally suitable for unfinished areas, or where floor is pitched to drain. Membrane Clamps - Most Watts floor and area drains have built-in clamping collars, used to attach and secure waterproofing membranes or liners, generally in above grade applications. Weep Holes / Double Drainage - Standard on all floor and area drains, weep holes direct water seeping around the drain top back into the sump. The 'Double Drainage' feature protects against deterioration of the area immediately surrounding the drain. Grate Openings - Floor and area drains supplied standard with 5/16" maximum openings. Grates are ADA compliant, and meet standard specifications for "heel proof". Consult product specifications for parking area applications. S-WD-FD-9 0812

FLOOR DRAIN SELECTION FACTORS Pipe Connection No Hub (Standard) - Butt connection using no hub or neoprene coupling, suitable for cast iron, plastic, and most other piping applications. Push-On (P) - Gasket connection ASTM C-564, with pipe stop. Suitable for no hub or service weight cast iron, Sch. 40 plastic, and steel pipe. Recommended for below grade only. Threaded (T) - Female IPS thread in drain outlet. Inside Caulk (X) - Caulk ring on drain outlet, pipe is inserted, and joint sealed with lead & oakum. PVC Socket (-60) - Sch. 40 PVC solvent weld female socket. ABS Socket (-61) - Sch. 40 ABS solvent weld female socket. Side Outlet (-SO) - No Hub (see above) side outlet. Commonly Specified Options Sediment Bucket (-5) - Catches debris, and prevents it from collecting in or blocking the drain trap. Vandal Proof (-6) - Allen head screws regularly furnished, torx & pin may be specified for high security applications. Trap Primer Tapping (-7) - 1/2" tapping on drain body, connects to trap primer valve (see Watts #A-200). Backwater Valve (-8) - For 2,3,4" drains only, neoprene float seal prevents back-up damage to finished areas. Serviceable through top of drain. Not for pressure applications. Hinged Grate (-9) - Available with select square tops, provides convenient access to drain buckets, or lines requiring regular maintenance. Galvanized (-13) - Cold zinc galvanizing, commonly specified in highly corrosive environments, such as coastal or industrial areas. Watts standard acid resistant epoxy coating eliminates the need for galvanizing in many applications. Strainer Extension (-15) - For FD-100 & FD-200 Series floor drains, extends strainer to accommodate thick fills or special applications. Secondary Strainer (-21) - Fits in base of drain sump, secondary protection against debris that bypasses sediment bucket. Closure Plug (-34) - Seals drain line, generally specified in areas where spillage of substances unsuitable for drainage may occur. Membrane Clamp (-C) - Specified in floors with a waterproofing membrane. Membrane clamps or clamping mechanisms are built in to most Watts floor drains. Round Funnel - 4" round cast iron (-F4-50) or nickel bronze (-F4-1) accepts single condensate lines. Specify 6" round nickel bronze (-F6-1) for large condensate lines. Bolt attaches funnel through underside of grate. Oval Funnel - 4x9" oval cast iron (-G-50) or nickel bronze (-G-1) accepts multiple condensate lines. Bolt attaches funnel through underside of grate. Elastomeric Flange (-Z) - Generally specified with poured or troweled elastomeric or rubberized floors. See FD-100-FC or FD-200-FC for elastomeric or rubberized sheet flooring. S-WD-FD-10 0812

TYPICAL INSTALLATIONS DRAIN STRAINER FLUSH FLUSH WITH WITH FINISH FINISH FLOOR FINISH FLOOR FINISH FLOOR SLAB SLAB WATERPROOFING MEMBRANE ROUGH ROUGH FLOOR FLOOR SLAB SLAB TRAP TRAP PRIMER PRIMER CONNECTION CAST CAST IRON IRON DRAIN DRAIN BODY BODY (PUSH ON SHOWN) SHOWN) REVERSIBLE COLLAR IN LOW POSITION FD-100-A REVERSIBLE COLLAR IN HIGH POSITION COLD WATER SUPPLY COLD WATER SUPPLY WATTS WATTS A 200 A200 TRAP TRAP PRIMER VALVE DRAIN STRAINER DRAIN STRAINER FLUSH FLUSH WITH FINISH WITH FINISH FLOOR FLOOR 1/2" TRAP PRIMER CONNECTION 1/2" TRAP PRIMER CONNECTION FINISH FLOOR ROUGH FLOOR SLAB ROUGH FLOOR SLAB ROUND FUNNEL FINISH FLOOR CAST IRON DRAIN BODY (PUSH ON SHOWN) CAST IRON DRAIN BODY (PUSH ON SHOWN) FD-200-A-7 ROUGH FLOOR SLAB ROUGH FLOOR SLAB DRAIN BODY CAST (PUSH ON IRON SHOWN) DRAIN BODY (PUSH ON SHOWN) S-WD-FD-11 0812 FD-200-EF

TYPICAL INSTALLATIONS DUCTILE DUCTILE IRON IRON GRATE SEDIMENT SEDIMENT BUCKET VANDAL PROOF VANDAL PROOF SCREWS CONCRETE WATERPROOF MEMBRANE MEMBRANE SLAB STRUCTURAL SLAB FD-320-Y-5-6 CAST IRON DRAIN DRAIN BODY (PUSH ON BODY SHOWN) (PUSH ON SHOWN) FINISHED FLOOR PLYWOOD FD-390-E-63 FLOOR JOIST SOIL STONE MEMBRANE WATERPROOF MEMBRANE FLOOR SUB FLOOR FD-860 PRECAST CONSTRUCTION PRECAST CONSTRUCTION DUCTILE IRON DUCTILE GRATE IRON GRATE SECURED SECURED WITH WITH VANDAL PROOF SCREWS HEAVY DUTY DUTY DRAIN DRAIN SUPPORT FLANGE SUPPORT FLANGE GASKET FD-900 UNDERDECK CLAMP CLAMP (OPTIONAL) (OPTIONAL) CAST IRON DRAIN DRAIN BODY BODY (NO SHOWN) (NO HUB SHOWN) S-WD-FD-12 0812