1 PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Roof drains 1. Coordinate location and depth of drains to assure adequate pitch of the drainage area to drain. 2. Overflow system shall be piped independently of the roof drain system. 3. Roof and overflow drainf to be installed in the same sump. 4. Size drains in accordance with ASPE Data Book, Volume 1, Fundamentals of Plumbing Design, Chapter 2, Storm Drainage Systems. 5. Consider storm drainage design criteria to avoid flooding and related water damage. 6. Design roof drains for ease of maintenance. 7. Coordinate the possible requirement for sanitary sewer drains on roofs, such as may be required for rooftop chillers and cooling towers, etc. 8. Also refer to Division 2 standards and Section B. Floor Drains 1. Provide floor drains in custodial, shower, toilet rooms, mechanical rooms and fan rooms and other areas as required, such as near reduced-pressure backflow preventers. 2. Floor sinks are required for indirect drains and are preferred in mechanical rooms. 3. Provide trap primers on all floor drains. C. Downspouts 1. Minimum downspout size 4" 2. Terminate with downspout nozzle at roof line. Do not terminate overflow downspouts low on the wall. D. Cleanouts 1. Design cleanout locations and access for minimum disturbance of occupant functions and building systems operation during cleanout servicing. 2. Provide cleanouts above urinals (56" AFF) and lavatory gangs (42" AFF or at least above flood level of lavatory). If wall is partially covered with tile, the cleanout shall be within the tile field or above it, not partially in each. 3. Provide cleanouts 6" above highest trap on that floor on the main vent of each group of fixtures and in vent stacks for isolated fixtures on each floor. 4. Provide full size cleanouts at base of each stack, maximum 50 foot intervals on horizontal runs, and at end of each horizontal run. 5. Provide cleanout plugs line-size up to 3", and 4" for line sizes 4" through 6". 6. Provide wall cleanouts where piping is concealed in walls or non-accessible chases, 42" AFF. 7. Where cast iron pipe is used, specify cleanouts with cast iron bodies and threaded "ABS" or "Delrin" plugs. 8. Design cleanout locations for easy access for rodding. 9. Provide identification on cleanout cover on pipe. 10. Provide 2-way cleanouts on all building sewers within 5-0 of building. E. Hose Bibbs 1. Provide hose bibbs with vacuum breakers in the following locations a) Each equipment room Page 1 of 6
2 b) Kitchen areas equipped with floor drainage systems c) Near cooling towers and condensers d) In public and student toilet rooms (provide locking cover recessed hose bibb) 2. Maximum spacing shall accommodate 50 of hose to any point within the drainage area, measured around obstructions and equipment. 3. Provide freeze proof hose bibs in exterior areas and unheated interior areas. F. Water Shock Arresters 1. Give careful attention to the prevention of water hammer in the design of water distribution systems. 2. Provide shock arresters in accordance with Plumbing Drainage Institute (PDI) Standard WH Require mounting as close to the line or quick-closing valve as possible. Remote mounting or excessive (over 6") nipple mounting will not be acceptable. 4. Provide full size ball valve and union from pipe to shock arrester. 5. Provide 12" by 12" minimum access panel centered on each shock arrester that is otherwise inaccessible. G. Reduced-Pressure Backflow Preventers 1. Provide backflow preventers in each water supply to mechanical equipment and systems and to other equipment and water systems that may be sources of contamination. 2. Locate backflow preventers in same room as connected equipment or system. 3. Provide drains for backflow preventers with atmospheric-vent drain connection with air-gap fitting, fixed air-gap fitting, or equivalent positive pipe separation of at least two pipe diameters in drain piping and pipe to floor drain. Locate air-gap device attached to or under backflow preventer. Simple air breaks are not acceptable for this application. 4. Do not install bypass piping around backflow preventers. 5. Refer to other Division 15 standards for additional requirements. H. Water Pressure Regulation 1. Average main pressure shall be determined by the A/E. The A/E shall acquire current water flow and pressure data from Denver Water and provide the necessary analysis to ensure that adequate pressure is supplied to the building for proper operation of plumbing fixtures. Refer to standards in Division 2 for additional requirements. 2. Use self-contained pressure regulating valves with stainless steel seat ring. 3. Valves shall have bronze bodies for 200 psi working pressure. 4. Use two valves, one to have capacity each for 70 percent of total load and one valve with capacity of 00 percent. 5. Reduced pressure for 30 percent valve shall be 68 psi, one of the 70 percent valves set at 64 psi. 6. Provide full-size wye-pattern strainer on inlet side of valve assembly. If strainer is used, install bypass for service. 7. Install pressure gages, complete with ball valves. 8. Gauge range 0 psi to 200 psi. 9. Gauges shall be on house side and on service side of each reducing valve inside of each shut-off valve for each PRV. 10. Entire PRV station shall have one full-size bypass with ball or butterfly valve Page 2 of 6
3 I. Temperature and Pressure Relief Valves: Provide relief valves on water heaters and pressure vessels per ASME Standard. J. Trap Primers: Provide trap primers where traps in floor drains may dry out and allow sewer gas to escape into building spaces, toilet rooms, and mechanical rooms. Water supply lines should not be insulated. Tail piece style trap primers and mechanical style trap seals are not allowed. K. Under-lavatory scald protection: Require pre-molded insulation covers for drains and water supplies to ADA-accessible lavatories. L. Stop-valves: Refer to standard Section Valves. M. Emergency Showers 1. Installation shall meet ANSI Z Provide tempered water to emergency showers. 3. Provide curb on floor to contain the ponding of water from the emergency shower. a) Comply with ICC/ANSI N. Water Meters 1. Specify contact-closure output. 2. Small domestic water meters 3. These meters are used for makeup and drain lines for irrigation only. 4. Hersey Measurement Co., Niagara Meter Line, MTX Series, Model 433, 1 percent accuracy, standard totalizer and calibrated contacts for remote monitoring 5. Water meter controls: Coordinate controls standards with the DPS Project Manager and the DPS Controls Application Engineer. PART 1 GENERAL 1.01 OPERATION AND MAINTENANCE DATA A. Include documentation of inspections and tests performed, including logs, curves, and certificates. B. Documentation shall note replacement of equipment or components that failed during testing. PART 2 PRODUCTS 2.01 MANUFACTURERS A. Floor drains, floor sinks, planter drains, deck drains, garage drains, trench drains, roof drains, downspout nozzles, storm drain expansion joints, cleanout fittings, sanitary vent terminal, and air gap fittings 1. Josam 2. J.R. Smith 3. Wade 4. Zurn (Kitchen Floor Sinks: Zurn Z-1751 Sani-Flor Receptor) B. Trench Drains (Heavy Duty Cast Iron Grate and Frame) 1. J-Mark Foundry 2. Maclear Manufacturing Co. 3. Neenah Foundry C. Sillcocks 1. Woodford D. Hose Bibbs Page 3 of 6
4 1. Finished rooms: Chicago Faucet 2. Unfinished & equipment rooms: Woodford E. Shock Arresters 1. Precision Plumbing Products Co. ("P.P.P.") F. Water Pressure Regulation Valve (Only) 1. Mueller 2. Watts G. Temperature and Pressure Relief Valves (Bronze or Brass) 1. Kunkle 2. Watts H. Trap Primers 1. Hersey 2. J. Water Meters 3. Precision Plumbing Products, Inc. ("P.P.P.") I. Water Meters 1. Hersey J. Under-lavatory scald protectors 1. Skal-Gard 2. Brocar Trap-Wrap 3. Truebro Lav-guard PART 3 EXECUTION 3.01 INSTALLATION A. Install pressure regulators with inlet and outlet shutoff valves and balance valve bypass. Install pressure gages on inlet and outlet. B. Install strainers on supply side of each control valve, pressure regulator, and solenoid valve. C. Install trap seal primer valves with outlet piping pitched down toward drain trap a minimum of 1 percent and connect to floor-drain body, trap, or inlet fitting. Adjust valve for proper flow. D. Install expansion joints on vertical risers, stacks, and conductors if indicated. E. Cleanouts in aboveground piping and building drain piping 1. Size same as drainage piping up to NPS 4. Use NPS 4 for larger drainage piping unless larger cleanout is indicated. 2. Locate at each change in direction of piping greater than 45 degrees. 3. Locate at minimum intervals of 50 feet for all piping. 4. Locate above the floor at the base of each vertical soil and waste stack. 5. Place two-way cleanouts (Texas Twin Cleanout) on all building sewers. F. For floor cleanouts for piping below floors, install cleanout deck plates with top flush with finished floor. G. Install cleanout wall access covers, of types indicated, with frame and cover flush with finished wall, for cleanouts located in concealed piping Page 4 of 6
5 H. Install flashing flange and clamping device with each stack and cleanout passing through floors with waterproof membrane. I. Install vent flashing sleeves on stacks passing through roof. Secure over stack flashing J. Install frost-proof vent caps on each vent pipe passing through roof. Maintain 1-inch clearance between vent pipe and roof substrate. K. Install floor drains at low points of surface areas to be drained. Set grates of drains flush with finished floor. 1. Position floor drains for easy access and maintenance. 2. Set floor drains below elevation of surrounding finished floor to allow floor drainage. Set with grates depressed according to the following drainage area radii. 3. Radius, 30 or less: Equivalent to 1% slope, but not less than ¼ total depression 4. Install floor-drain flashing collar or flange so no leakage occurs between drain and adjoining flooring. Maintain integrity of waterproof membranes where penetrated. 5. Install individual traps for floor drains connected to sanitary building drain. L. Roof drain installation 1. Install roof-drain flashing collar or flange so no leakage occurs between drain and adjoining roofing. Maintain integrity of waterproof membranes where penetrated. 2. Position roof drains for easy access and maintenance. 3. Also refer to Division 7 standards. M. Interceptors, including trapping, venting, and flow-control fittings 1. Install with adequate clear space for servicing. 2. Above-Floor Installation: Set unit with bottom resting on floor. 3. Flush with Floor Installation: Set unit and extension, if required, with cover flush with finished floor. 4. Recessed Floor Installation: Set unit in receiver housing having bottom or cradle supports, with receiver housing cover flush with finished floor. 5. Install cleanout immediately downstream from interceptors not having integral cleanout on outlet. 6. Place two-way cleanouts (Texas Twin Cleanout) on all inteceptors (grease, oil, acid neutralization, ect.) inlet and outlet. N. Fasten wall-hanging plumbing specialties securely to supports attached to building floor. Floor mounted carriers are required for wall-mounted plumbing fixtures. O. Fasten recessed-type plumbing specialties to reinforcement built into walls. P. Valves 1. Install individual shutoff valve in each water supply to plumbing specialties. 2. Use ball valve if specific valve is not indicated. 3. Install shutoff valves in accessible locations. 4. Refer to Specification Section Valves for general-duty ball, butterfly, check, gate, and globe valves. Q. Install air vent at piping high points. Include ball or globe valve in inlet and drain piping from outlet to floor drain. R. Install traps on plumbing specialty drain outlets. Omit traps on indirect wastes unless trap is required. S. Install escutcheons at wall, floor, and ceiling penetrations in exposed finished locations and within cabinets and millwork. Use deep-pattern escutcheons if required to conceal protruding pipe fittings Page 5 of 6
6 END OF SECTION Page 6 of 6
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES
SECTION 22 42 00 COMMERCIAL PLUMBING FIXTURES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
FIRING RANGE PHASE 1 DESIGN 224500-1
FIRING RANGE PHASE 1 DESIGN 224500-1 SECTION 224500 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
Element D Services Plumbing
PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses domestic cold, hot and hot water return distribution systems within and to five feet beyond building perimeter. PART 2 - DESIGN CRITERIA 2.01 GENERAL
SECTION 15412 SOIL AND WASTE SYSTEMS
SECTION 15412 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work
A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.
SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information
What to Expect From the Examination. How to Study the Plumbing Codes
Texas State Board of Plumbing Examiners Plumbing Inspector Examination Review Course The following Examination Review Course is designed to assist an applicant in preparing for the Plumbing Inspector examination.
Amendments to the 2012 International Plumbing Code
Amendments to the 2012 International Plumbing Code North Central Texas Council of Governments region The following sections, paragraphs, and sentences of the 2012 International Plumbing Code are hereby
A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.
SECTION 22 45 00 - (ADD#2) PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
112039.00 224500 EMERGENCY PLUMBING FIXTURES
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following emergency plumbing fixtures: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Hand-held drench hoses. 5. Combination
When Should Examination Preparation Begin?
Texas State Board of Plumbing Examiners Tradesman Plumber-Limited Licensee Examination Review Course The following Examination Review Course is designed to assist a registered Plumber s Apprentice in preparing
PLUMBING ROUGH IN INSPECTION
This Program is made Possible through the Code Officials Education & Training Fund. Revenue for the Fund comes from Assessments on Building Permits. Please turn down cell phones and put pagers on vibrate.
Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector
Plumbing Helpful Hints Residential Construction Bert Polk Plumbing Inspector Lincoln County 2015 Waste and vent fittings Vent 90 medium 90 long 90 1/16 bend,1/8 bend,1/6 bend, medium 90 san tee combination
DIVISION 22 PLUMBING. 22 30 00 PLUMBING EQUIPMENT 22 33 00 Domestic Water Heaters
DIVISION 22 PLUMBING 22 00 00 PLUMBING 22 00 50 Design Criteria 22 01 00 General Requirements 22 05 00 Common Work Results 22 06 00 General Duty Valves 22 07 00 Insulation 22 08 00 Commissioning 22 10
A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.
SECTION 224500 - EMERGENCY PLUMBING FIXTURES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
22 12 00 FACILITY POTABLE WATER STORAGE TANKS
DIVISION 22 PLUMBING 22 11 16 DOMESTIC WATER PIPING 22 11 19 DOMESTIC WATER PIPING SPECIALTIES 1. To facilitate landscape and other maintenance operations, exterior hose bibs shall be provided at 50 foot
Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
Plumbing Code Sections For Commercial Food Facilities
Plumbing Code Sections For Commercial Food Facilities SCOPE The following list of requirements summarizes the plumbing issues that are commonly addressed in commercial retail food facilities by health
5.23.22 STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL. 1.01 Purpose:
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
Arapahoe County Residential Water Heater Installation and Inspection Guide
Arapahoe County Residential Water Heater Installation and Inspection Guide The attached handout is designed to be a general permit submittal and inspection guide covering most installation instances, however
EFFECTIVE FEBRUARY 2014. note: drainage permit required to call for a dampproof inspection
EFFECTIVE FEBRUARY 2014 note: drainage permit required to call for a dampproof inspection 1. ROOF DRAINS/DECK DRAINS (INTERIOR ) All roof and deck drains within the perimeter of the building shall be APPROVED
Chapter 7 Plumbing Connections
Chapter 7 Plumbing Connections 7-1 General All plumbing equipment and installations must be designed, constructed, and installed in accordance with this code and where not specific, to the applicable provisions
Residential Plumbing BCN 1058
Residential Plumbing BCN 1058 CHAPTER 7 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System MICHAEL KNOTEK 74 Plumbing Fixtures and Sizing the Drain, Waste, and Vent System PLUMBING FIXTURES
2006 Codes. Please verify the following before calling for inspection
INSPECTION CHECKLIST RESIDENTIAL PLUMBING ROUGH IN 2006 Codes This checklist is intended for use to prepare for an inspection. This is only a general list and is not intended to address all possible conditions.
Top 10+ Mistakes of DWV plumbing design
Top 10+ Mistakes of DWV plumbing design Listed below are the some of the most frequently missed items, noticed by our inspectors, at plumbing rough-in when non-plumbers attempt plumbing design. Most of
SECTION 221413 FACILITY STORM DRAINAGE PIPING
SECTION 221413 FACILITY STORM DRAINAGE PIPING PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
CHAPTER 11 STORM DRAINAGE
CHAPTER 11 STORM DRAINAGE SECTION 11 GENERAL 11.1 Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. 11.2 Where required. All roofs,
B. Shop Drawings: Diagram power, signal, and control wiring.
SECTION 224500 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Emergency showers. 2. Eyewash equipment. 3. Eye/face wash equipment. 4. Combination units. 5. Water-tempering equipment. 1.2 SUBMITTALS
All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.
DIVISION 15 MECHANICAL SECTION 15100 - PLUMBING PART 1 - GENERAL SCOPE Plumbing work includes all domestic water, gas, and sanitary sewer systems as shown on plans. Also all fixtures and equipment which
DIVISION 22 PLUMBING. 22 30 00 PLUMBING EQUIPMENT 22 33 00 Domestic Water Heaters
DIVISION 22 PLUMBING 22 00 00 PLUMBING 22 00 50 Design Criteria 22 01 00 General Requirements 22 05 00 Common Work Results 22 06 00 General Duty Valves 22 07 00 Insulation 22 08 00 Commissioning 22 10
Teacher Assessment Blueprint. Plumbing. Test Code: 5175 / Version: 01. Copyright 2010 NOCTI. All Rights Reserved.
Teacher Assessment Blueprint Plumbing Test Code: 5175 / Version: 01 Copyright 2010 NOCTI. All Rights Reserved. General Assessment Information Blueprint Contents General Assessment Information Written Assessment
CHAPTER 11 STORM DRAINAGE
CHAPTER STORM DRAINAGE SECTION PC 0 GENERAL 0. Scope. The provisions of this chapter shall govern the materials, design, construction and installation of storm drainage. Storm water discharge shall be
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES
AIR RELEASE, CLEANOUT, AND SEWER MANHOLES **From Hartford IM BLDG(10) DESCRIPTION. This work shall consist of the construction of air release, cleanout, and sanitary sewer manholes; and the furnishing
DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES
SECTION 15062 STEAM AND CONDENSATE PIPING PART 1 DESIGN DIRECTIVES 1.1 QUALITY ASSURANCE A. Comply with the provisions of the following: 1.2 DESIGN CRITERIA 1. ASME B 31.9 Building Services Piping : for
CODE GUIDE 302 and Glossary of Industry Terms
CODE GUIDE 302 and Glossary of Industry Terms A Guide for Code Authorities and Others for Selected - % Plumbing and Drainage Products Issued By THE PLUMBING AND DRAINAGE INSTITUTE 800 Turnpike Street ~
Town House 11265 Center Highway North Huntingdon, PA 15642
APPENDIX C SPECIFICATIONS FOR THE CONSTRUCTION OF BUILDING LATERAL SANITARY SEWERS DECEMBER 2004, INCLUDING AMENDMENTS ADOPTED ON FEBRUARY 6, 2008 AND APRIL 2, 2008; EFFECTIVE ON MAY 1, 2008 Town House
CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004
Bellevue Bothell Kenmore Kirkland Issaquah Mercer Island Sammamish Snoqualmie Woodinville CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004 This checklist is intended for use to prepare
PLUMBING & CROSS-CONNECTION CONTROL
PLUMBING & CROSS-CONNECTION CONTROL. MODULE 4 VII. Typical Retail Food Service Cross-Connections VIII. Air Gaps and Air Breaks for Drains and Waste IX. Grease Interceptors VII. TYPICAL RETAIL FOOD SERVICE
Jay R. Smith Mfg. Co.
Jay R. Smith Mfg. Co. Automatic Backwater Valve SMITH CUSTOMER DRIVEN FLOOD-GATE FEATURES Index Page Flood-Gate Features and Applications 2 How Flood-Gate Works 3 Flood-Gate Operation & Approvals 4 Valve
ROOF DRAINS TABLE OF CONTENTS
Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF
INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville
Bellevue Bothell Burien Issaquah Kenmore Kirkland INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville 2009 Codes This
CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS
PlumbingCode06_ch10 5/29/06 8:16 AM Page 1 CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS We have covered most of the regulations you will need to know about drains and vents. This chapter will round out
12. Design of plumbing systems for single dwellings
12. Design of plumbing systems for single dwellings 12.1 General considerations A single dwelling is a building designed for a single family or a group living as a family. It may be a house of one storey
Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents
Chapter 1 Administration Chapter 3 General Regulations Chapter 5 Water Heaters Chapter 7 Sanitary Drainage Chapter 9 Vents Chapter 11 Storm Drainage Policy Statements Table of Contents Chapter 2 Definitions
PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC
PLAN CHECK CORRECTION SHEET FOR PLUMBING SYSTEMS 2014 LAPC This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. Section:
2010 Residential Water Heater Replacement Check List
2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This
WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION
WELCOME INTERNATIONAL RESIDENTIAL CODE 2009 EDITION PLUMBING SECTION 1 HOUSEKEEPING 2 CHANGES We will be covering the significant changes to the International Residential Code and the changes common to
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES
PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES Health Systems Protection Rev. 07/2006 35-05-20/06/07/18 OFFICE OF FOOD PROTECTION 417 FEDERAL ST
SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y
Foundation A foundation is the bottom part of a building. It s the element that anchors the building to the ground and transmits the building s gravity load directly to the earth. Water damage weakens
BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)
BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version) Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash,
ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007
ONE AND TWO FAMILY DWELLINGS Plumbing July, 2007 The following are general requirements pertaining to plumbing in one and two family dwellings. This does not represent all the provisions regulating plumbing
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment
Plugging Home Drains to Prevent Sewage Backup
AE-1476 Plugging Home Drains to Prevent Sewage Backup Why plug drains For homes in areas of the country prone to flooding or heavy rain, taking a few steps to prepare for water levels that could result
CLARK COUNTY DEPARTMENT OF BUILDING COMMERCIAL PLUMBING AND MECHANICAL INSPECTION CHECKLISTS 2006 CODE
CLARK COUNTY DEPARTMENT OF BUILDING COMMERCIAL PLUMBING AND MECHANICAL INSPECTION CHECKLISTS 2006 CODE GENERAL NOTES This checklist is intended for use as a GUIDE to assist and promote consistency in the
FIX TURE CARRI ERS. 140(a) MPB-2011-USA
FIXTURE CARRIERS STRUCTURAL FEET The feet are heavy duty cast ductile iron and invertible. No distinction is necessary between right and left hand. Each foot wraps around the specially formed edge of the
PLAN REVIEW SERVICES CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW
CONSTRUCTION DOCUMENTS NECESSARY FOR A THOROUGH PLAN REVIEW PRELIMINARY BUILDING REVIEW two sets of the following: Architectural/engineering design development drawings indicating size of the building,
Job Ready Assessment Blueprint. Plumbing. Test Code: 3061 / Version: 01
Job Ready Assessment Blueprint Plumbing Test Code: 3061 / Version: 01 Measuring What Matters Specific Competencies and Skills Tested in this Assessment: Professionalism Exhibit professional behavior Describe
BRADLEY HALO EMERGENCY PLUMBING FIXTURES
BRADLEY HALO EMERGENCY PLUMBING FIXTURES Bradley Halo Emergency Plumbing Fixtures are a new generation in safety equipment, featuring separate supply and waste piping to eye/face wash, ergonomic hand activation
15430 SAFETY SHOWERS AND EYEWASHES
15430 SAFETY SHOWERS AND EYEWASHES PART 1: GENERAL 1.01 RELATED SECTIONS 01005 - ENVIRONMENTAL HEALTH 11600 LABORATORY EQUIPMENT 15020 - LABORATORIES 15130 - PIPING SPECIALITES 15400 - PLUMBING 15420 -
Residential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012
Plumbing Code in Commercial Kitchens NH BOA May 9, 2012 Main Topics Grease Interceptors Indirect Waste Receptors Cleaning Chemical Dispensers Thermal Expansion IPC - Chapter 10 Traps Interceptors Separators
Plumbing Code in Commercial Kitchens
Plumbing Code in Commercial Kitchens City of Concord Code Administration 225-8580 Dan Clark Plumbing Inspector Tedd Evans, Chief Building Inspector Code References from the 2009 edition of the International
INTERCEPTORS TABLE OF CONTENTS S-WD-INTER-1 0812
TABLE OF CONTENTS Pictorial Index Product Recommendations Grease Interceptors Commonly Specified Options Typical Installations Oil Interceptors Commonly Specified Options Typical Installations Sediment
PMA ONLINE TRAINING Venting for Plumbing Systems
PMA ONLINE TRAINING Venting for Plumbing Systems One Hour Continuing Education Venting PMA training disclaimer The information provided in this document is intended for use as a guideline and is not intended
Backflow Bulletin #1
Backflow Bulletin #1 FIRE PROTECTION SYSTEMS Chemicals in the System Anti-Freeze, Foam, Corrosion Inhibitors, etc. Chemicals in the System Glycerin Glycerin or similar food-grade non-toxic additive Siamese
CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY
Draft CITY of LOS ANGELES DEPARTMENT of BUILDING and SAFETY Draft Los Angeles Plumbing Code (LAPC) 2008 California Plumbing Code (CPC) 2007 Uniform Plumbing Code (UPC) 2006 Major Code Changes Preliminary
One of the fundamental design elements that every
Preliminary Design Information Before starting the water system design, you must assemble a collection of information. This includes information from the owner, the local utility, and the architect. Things
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS
Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS Contents Page Ratings and Specifications..................... 2 Installation Requirements......................
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
CHAPTER 7 SANITARY DRAINAGE
701 GENERAL 701.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of sanitary drainage systems. 701.6 Frost Protection No soil or waste pipe shall
NYC Department of Education Building Condition Assessment Survey 2014-2015 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004
School: InspectionId Asset Data Inspection Type Building Assessment Survey 204-205 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 0004 Time In Last Edited 255 MECHANICAL 205-05-8 09:00AM
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division
Brian Coppock, Regional Compliance Officer Office of Statewide Health Planning and Development Facilities Development Division CHAPTER 6 WATER SUPPLY AND DISTRIBUTION 601.0 Hot and Cold Water Required.
GRATES AND DRAINS HOUSTON ORLANDO GREENVILLE 800/392-5066 800/327-3022 800/476-2212 TOTAL MAINTENANCE SOLUTIONS
15-1 CLEANOUT COVERS 47471082 4-11/16 Josam, 3 screw 47471084 6-5/16 Josam, 3 screw 47761070 5-7/16 Smith, 3 screw w/ closure plug 47941108 6-1/4 Wade, 3 screw 47991400 4-5/8 Zurn, 3 screw 47991402 6-1/8
CHAPTER 5 WATER HEATERS
PlumbingCode06_ch05 5/29/06 8:12 AM Page 1 CHAPTER 5 WATER HEATERS Water heaters are only a small portion of a plumbing system, but they are important, and they can be dangerous. Many plumbers take water
SECTION 00 0110 TABLE OF CONTENTS. H. 00 2115.01 - Proposed Material, Product or Equipment Substitution Request
SECTION 00 0110 PROCUREMENT AND CONTRACTING REQUIREMENTS 1.1 DIVISION 00 -- PROCUREMENT AND CONTRACTING REQUIREMENTS A. 00 0101 - Project Title Page B. 00 0105 - Certifications Page C. 00 0110 - Table
CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.
CHAPTER 9 VENTS 901 GENERAL 901.1 Scope The provisions of this chapter shall govern the materials, design, construction, and installation of vents. 901.2 Protection of Trap Seals The protection of trap
CHAPTER 26 PLUMBING CODE
CHAPTER 26 PLUMBING CODE 26.01 PLUMBING CODE The Illinois Plumbing Code as promulgated by the Illinois Department of Public Health at 77 Illinois Administrative Code, Part 890, is hereby adopted as the
Inspection Item COMMENTS
APPENDIX 9 AFFORDABLE HOUSING PROGRAM INSPECTION CHECKLIST Participating Jurisdiction: Homeowner Name: Assisted Property Address: Date of Physical Inspection of Property: Total Square Footage of Property:
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503. Re-Roofing: Asphalt Shingles
CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN 55110 Fax: 651-429-8503 Re-Roofing: Asphalt Shingles This is a summary of the standard requirements based on the
PLUMBING. For HOME OWNERS
PLUMBIG For HOM OR If your property is located in the ational cenic rea, the Columbia River Gorge IRODUCIO Commission requires you to comply with all ational cenic rea regulations. hey can be contacted
CLEANOUT FEATURES. KLEENATRON II Features CLEANOUTS
CLEANOUT FEATURES KLEENATRON II Features JOSAM KLEENATRON II Cleanouts incorporate features developed to meet the latest in building construction methods. These features ensure the specifier, installer
Report for. Dick and Jane Homeowner. 1234 Lovers Lane, Houston, Texas 77000
Report for Dick and Jane Homeowner 1234 Lovers Lane, Houston, Texas 77000 March 17, 2004 I NI NP R Inspection Item I. STRUCTURAL SYSTEMS o o o A. Foundations (If all crawl space areas are not inspected,
A. This Section includes the following for soil, waste, and vent piping inside the building:
June 2014, Draft 01 22 1316 Sanitary and Waste Vent Piping PART 1. GENERAL 1.01 Summary A. This Section includes the following for soil, waste, and vent piping inside the building: 1. Pipe, tube, and fittings.
Downspout to storm sewer. Leaky laterals
Flooded street Surface water through MH top Blocked street catch basin Cracked MH or sewer Property line Downspout to storm sewer BREATHERS Leaky laterals Weeping Tile to sanitary or storm sewer BASEMENT
Carriers, Fixtures & Piping
Regardless of application and/or installation needs, there are fixture supports available to meet even the harshest design requirements. by William M. Smith Over the years, I m sure that each of you in
Building, Plumbing, Electrical and Residential Water and Sewer Inspection Requirements
Building, Plumbing, Electrical and Residential Water and Sewer Inspection Requirements Charles County Government Planning and Growth Management P.O. Box 2150, La Plata, MD 20646 (301) 645-0692 Schedule
TYPE E Main Valve Sizes 3 /8 through 12
SD 3001F PRINTED IN U.S.A. SD 3001F/0707 A B TYPE E MAIN VALVE C D E TYPE E Main Valve Sizes 3 /8 through 12 The Spence Type E Main Valve is of normally closed, single seat design featuring packless construction,
FAQ and Device/Usage Chart. What Is a Cross-Connection? What Is Backflow Prevention? What Is Backflow?
What Is a Cross-Connection? A cross-connection is a direct arrangement of piping that allows the potable (safe drinking) water pipe to be connected to a pipe supply that contains a contaminant or pollutant.
Burns Home Services SUMMARY REPORT. 7/18/2006 Start: 9:00 am End: 12:30 pm
Burns Home Services Service Makes the Difference 2620 W Grovers Ave, Phoenix, AZ 85053 Tel: 602-889-6970 Fax: 602-870-4563 Mobile: 602-291-7138 [email protected] SUMMARY REPORT Client: John
Basic Principles for Sizing Grease Interceptors
Basic Principles for Sizing Grease Interceptors Grease Interceptor is an overall term. It is a product category much like faucet. I am sure you can think of several types of faucets like, kitchen, bath
SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;