End of Life: 1494V Variable-depth Disconnect Switch (30 100 A) End of Life: 1494C Cable-operated. Product Lifecycle



Similar documents
Rotary Disconnect Switch Specifications

Circuit Breakers. Next Generation of Protection Capabilities

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Selection Guide. Bulletin 194R/140U External Operating Handles

DC disconnects for solar photovoltaic installations. Connecting the. power of the sun

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Connecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Secondary Unit Substations

Bimetallic Overload Relay Specifications

Distribution Dry Type Transformers

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Catalog January. Heavy industrial power applications Motor contactors and starters

Heavy Duty Safety Switches

Solid State Timers Type F

Metallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features

MOBILE HOME SERVICE REQUIREMENTS GAS

1756 ControlLogix Chassis Specifications

SPEEDFAX TM 2011 Disconnect Switches Contents

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

PSR The compact range Description

Photovoltaic Solar Energy Unit EESFB

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

BRITISH STYLE SEMICONDUCTOR PROTECTION FUSES

Series 8146/5-V37 and Series 8150/5-V37

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Cutler-Hammer January 1999

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

3500/93 System Display

P70, P72, and P170 Series Controls for Dual Pressure Applications

SMC -3 Specifications

General Purpose, Interposing, Solid-State and Specialty Relays. Bulletin 700

T7079A,B Solid State Remote Temperature Controllers

Industrial Control Power Transformers

Disconnect Switch and Circuit Breaker Mechanism Specifications

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

Square D Safety Switches

Plug and Socket Devices SolConeX 16 A Series 8570

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Technical Data. Dimensions

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

CompactLogix Power Supplies Specifications

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

5SV Residual Current Protective Devices

MCR1900 Media Converter 19-Slot Chassis

Centro-Matic Automatic Lubrication Systems System Controls

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Bolted contact switches. Pringle switches

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

ASCO SERIES 185 Power Transfer Switches

AC METRIC (IEC) MOTORS THREE PHASE

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Multi-Function Ground

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

Plug and Socket Devices CES 63 A Series 8579

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Vertical Break Parallel (VBP) / Vertical Break Slant (VBS)

Class 58 Drum Controller Catalog & Price List November 2015, Replaces Jan 2015

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

General 1-2-Opto-electronics Safety Switches 4-Emergency

BETA Protecting SITOR Semiconductor Fuses

Renewable energy. Inverters - Socomec G-1. Load break switches (Isolators) - Socomec G-2. Fuses - df G-3. Fuse bases.

Plugs and Receptacles

Series Six Plus Programmable Controller

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

T1-K. OPEN SLOT RIGID PVC (including cover) OPEN SLOT BLACK RIGID PVC (including cover) 2 PRICE LIST WD 115 STANDARD CARTON - FT LENGTHS PER CARTON

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Solar Power Solutions

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

LC/LCD ranges level controllers

Manual motor starter MS116

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

R.C.C.B. s two-pole LEXIC

Specification Requirements DBL 700MX and 1000MX Series UPS

MCC Ratings. Voltage Rating

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

Continuous Power... Continuous Protection

Foxboro Evo Process Automation System

IEC Connectors. Introduction

TrueAlarm Fire Alarm Systems

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

GE Power Controls. MiniFORM Switchboards

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

Easy Installation All five standard monitors fit into shallow mounting areas, requiring about 3" of depth. The XT1502, SXT1811, and SXT2011 models hav

TS-770 SERIES CONFERENCE SYSTEM

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

ELECTRIC METERING COMMERCIAL & INDUSTRIAL

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

SWITCHGEAR. EGP Switchgear

Transcription:

Migration Solutions 1494V Rod-operated and 1494C Cable-operated Disconnect Switches to 1494U Universal Disconnect Switch 1494U Universal Visible-Blade Disconnect Switch Features and Benefits Users who apply Allen-Bradley Bulletin 1494 visible-blade disconnect switches in applications of 100 amps and lower can now take advantage of the flexibility and convenience of the new bulletin 1494U Universal Disconnect Switch product line. A single universal mechanism accommodates rod-actuated and cable-actuated installations. End of Life: 1494V Variable-depth Disconnect Switch ( 100 A) Visible blade design determine if the switch is ON or OFF at a glance Global acceptance designed and tested to various international standards 1494U Universal Disconnect Switch Universal mechanism same switch can be connected to a threaded rod or a cable mechanism for reduced inventory Smaller foot print up to 50% less panel space required Ease of installation modular components with simple instructions in both printed and video formats Thinner cable design more flexibility with six inch bend diameter Switch design integrates phase barriers with line and load markings into the switch body Fuse barriers scored for different fuse lengths and included with each fuse block Snap-on accessories faster installation End of Life: 1494C Cable-operated Disconnect Switch ( 100 A) Product Lifecycle Use the Product Lifecycle Status search tool on the web to find specific lifecycle information by catalog number. ACTIVE ACTIVE MATURE END OF LIFE DISCONTINUED ACTIVE: Most current offering within a product category. ACTIVE MATURE: Product is fully supported, but a newer product or family exists. Gain value by migrating. END OF LIFE: Discontinued date announced actively execute migrations and last time buys. Product generally orderable until the discontinued date. 1 DISCONTINUED: New product no longer manufactured or procured. 2 Repair/exchange services may be available. 1 - Outages on specific items may occur prior to the Discontinued date. 2 - Limited stock may be available in run-out mode, regionally.

1494V Rod-operated and 1494C Cable-operated Disconnect Switches to 1494U Universal Disconnect Switch The 1494V and 1494C catalog numbers being discontinued are listed in the table below with a cross reference to the recommended 1494U catalog number(s). These are functional replacements and you need to select correct accessories to meet functional as well as installation requirements. Catalog Number Migration Disconnect Switch Components Discontinued 1494V-DS 1494V-DS60 1494V-DS100 1494V-DSX 1494V-DSX60 1494V-DSX100 1494F-D 1494F-D60 1494F-D100 1494F-DX 1494F-DX60 1494F-DX100 1494C-CM1 1494C-CM2 1494C-CM3 1494C-CM4 1494C-CMX1 1494C-CMX2 1494C-CMX3 1494C-CMX4 1494V-FS 1494V-FS60 1494V-FS100 Replacement Catalog Number 1494U-D 1494U-D60 1494U-D100 no longer available, use 1494U-D no longer available, use 1494U-D60 no longer available, use 1494U-D100 1494U-D 1494U-D60 1494U-D100 no longer available, use 1494U-D no longer available, use 1494U-D60 no longer available, use 1494U-D100 1494U-C313 1494U-C314 1494U-C315 1494U-C316 Left hand cable mechanism no longer available, use 1494U-C313 Left hand cable mechanism no longer available, use 1494U-C314 Left hand cable mechanism no longer available, use 1494U-C315 Left hand cable mechanism no longer available, use 1494U-C316 1494U-F 1494U-F60 1494U-F100 Disconnect Switch Components Note: The catalog numbers listed below are not being discontinued. It is recommended, however, that customer migrate to the equivalent 1494U products. Existing Catalog Number Equivalent 1494U Catalog Number 1401-N41 1494U-FC2J 1401-N42 1494U-FCJ 1401-N43 1494U-FC60J 1401-N44 1494U-FC100J 1401-N50 1494U-FC2R 1401-N51 1494U-FCR 1401-N52 1494U-FC60R 1401-N53 1494U-FC100R 1494F-M1 1494U-HM1 1494F-P1 1494U-HP1 1494F-S1 1494U-HS1 1494V-RA3 1494U-R1 (for use in enclosure depths up to 20") 1494V-RA4 1494V-RA4 (for enclosure depths between 21" to 24" 1495-N8 1494U-NO 1495-N8X 1494U-NOLV 1495-N9 1494U-NC 1495-N9X 1494U-NCLV 1495-N34 1494U-AE 1495-N35 1494U-AE 1494R-N1 1494U-LA36; if copper lug is required use 1494U-LC36 1494R-N2 1494U-LA100; if copper lug is required use 1494U-LC100 1495-N64 1494U-PC1 1495-N65 1494U-PC2 1495-N66 1494U-PC2 1494R-N16 1494U-LT31 1494R-N17 1494U-LT31 1494R-N18 1494U-LT31

Disconnect Switch Kits Below is a partial list of kits from the 1494V and 1494C product lines, along with the truncated 1494U kit. Please see your distributor for more specific catalog numbers. Existing 1494V or 1494C Catalog Number *DH633* *DH666* *DH611* *DHX633* *DHX666* *DHX611* Equivalent 1494U Catalog Number 1494U-J* 1494U-J60* 1494U-J100* Left-hand version no longer available use a cable version; 1494U-J-C* Left-hand version no longer available use a cable version; 1494U-J60-C* Left-hand version no longer available use a cable version; 1494U-J100-C* *DJ633* 1494U-J-CR * *DJ666* 1494U-J60-CR* *DJ611* 1494U-J100-CR* *DJX633* Left-hand version no longer available use a cable version; 1494U-J-C3* *DJX666* Left-hand version no longer available use a cable version; 1494U-J60-C3* *DJX611* Left-hand version no longer available use a cable version; 1494U-J100-C3* *DN* 1494U-N-C* *DN60* 1494U-N60-C* *DN100* 1494U-N100-C* *DNX* Left-hand version no longer available use a right-hand version; 1494U-N-C* *DNX60* Left-hand version no longer available use a right-hand version; 1494U-N60-C* *DNX100* Left-hand version no longer available use a right-hand version; 1494U-N100-C* *DR633* 1494U-R-C* *DR666* 1494U-R60-C* *DR611* 1494U-R100-C* *DRX633* Left-hand version no longer available use a right-hand version; 1494U-R-C* *DRX666* Left-hand version no longer available use a right-hand version; 1494U-R60-C* *DRX611* Left-hand version no longer available use a right-hand version; 1494U-R100-C* Note: The catalog numbers listed below are a Series A to Series B change only. 1494F-N (Fixed Depth) 1494F-N60 (Fixed Depth) 1494F-N100 (Fixed Depth) 1494F-F (Fixed Depth) 1494F-F60 (Fixed Depth) 1494F-F100 (Fixed Depth)

Bulletin 1494U Sample Catalog Number a Bulletin Number U Disconnect switch rod or cable operated * * Aluminum lugs are provided with each disconnect switch. 1494 U - R - C3 a b c d N J R b Fusing R.H. Non-fusible R.H. Class J clips R.H. Class R clips c Switch & Fuse Rating Non-fusible (N) A switch 60 60 A switch 100 100 A switch Fusible (J, R) 600V, A switch, 60 600V, 60 A switch, 100 600V, 100 A switch, d Accessories CR Threaded rod (19" maximum) C3 Cable length (3 feet) C4 Cable length (4 feet) C5 Cable length (5 feet) C6 Cable length (6 feet) M Painted metal handle N Non-metallic handle NO (1) N.O. auxiliary contact (10 A) NC (1) N.C. auxiliary contact (10 A) PC Protective cover for line & load S Stainless steel handle Bulletin 1494V and 1494C Sample Catalog Number a Bulletin Number V Rod operated C Cable operated 1494 V - DR 233 - A - B - FF a b c d Fusing Switch with right hand mechanism b DN Non-fusible DH Class H fuse clips DJ Class J fuse clips DR Class R fuse clips Switch with left hand mechanism DNX Non-fusible DHX Class H fuse clips DJX Class J fuse clips DRX Class R fuse clips Switch & Fuse Rating Non-fusible c A switch 60 60 A switch 100 100 A switch Fusible 233 250V, A switch, 236 250V, A switch, 263 250V, 60 A switch, 266 250V, 60 A switch, 261 250V, 60 A switch, 211 250V, 100 A switch, 212 250V, 100 A switch, 200 A clips 633 600V, A switch, 636 600V, A switch, 663 600V, 60 A switch, 666 600V, 60 A switch, 661 600V, 60 A switch, 616 600V, 100 A switch, 600V, 100 A switch, 611 612 600V, 100 A switch, 200 A clips d Optional Accessories (field installed) A Long connecting rod A3 3 ft cable A4 4 ft cable A5 5 ft cable A6 6 ft cable A10 10 ft cable B Stainless steel handle B1 Painted metal handle C Non-metallic handle Standard-sized D line & load lugs D1 Oversized line & load lugs # E Protective fuse cover F (1) N.O. auxiliary contact * FF (2) N.O. auxiliary contacts * G (1) N.C. auxiliary contact * GG (2) N.C. auxiliary contacts * (1) N.O. and (1) N.C. H electrical interlock (2) N.O. and (2) N.C. HH electrical interlocks For use with 200 A switches. # Only available with 200 A and 400 A switches. * Maximum of (2) auxiliary contacts.

Bulletin 1494U Dimensions Dimensions are in millimeters. Dimensions are not intended to be used for manufacturing purposes. Bulletin 1494U Disconnect Switch and Fuse Block, 60 A 6.82 3.32

Bulletin 1494U Dimensions Dimensions are in millimeters. Dimensions are not intended to be used for manufacturing purposes. Bulletin 1494U Disconnect Switch and Fuse Block, 100 A

Bulletin 1494U Dimensions Dimensions are in millimeters. Dimensions are not intended to be used for manufacturing purposes. Bulletin 1494U Handle with Cable Support Bracket

Specifications Electrical Ratings Switch Size A 60A 100A AND FUSE RATING ible (N) 0A switch 0A switch 00A switch 00A switch 00A switch 00A switch J, R) 00V, A switch, A clips 00V, 60A switch, 60A clips 00V, 100A switch, 100A clips 00V, 200A switch, 20A clips 00V, 400A switch, 400A clips 00V, 600A switch, 600A clips Rated insulation voltage Ui (UL) IEC - C3 Ratings CODE ACCESSORIES UL/CSA/NEMA CR Threaded Rod (19 maximum) C3 Cable length (3 feet) C4 Cable length (4 feet) C5 Cable length (5 feet) C6 Cable length (6 feet) M Painted Metal Handle NO (1) N.O. auxiliary contact (10A) (1) N.C. auxiliary contact (10A) Protective cover - for line & load Stainless steel handle NC Ratings PC IEC S Applications Hp Continuous Current Maximum kw (AC23) 2V/60 Hz 406V/60 Hz 575V/60 Hz (600) 660V 7.5 15 20 600V DC 15 50 600V AC 250V DC 220V/50 Hz 440V/50 Hz 550V/50 Hz 15 50 60 75 60 100 5.5 11 15 11 22 37 22 45 55 0A 100A 5 0 0 60 75 0 20 For additional documentation, including installation videos, scan the QR code above or go to http://www.rockwellautomation.com/go/pd/1494u-doc 0 100 1 2 7 22 45 55 n, Inc. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved. Printed in USA. Allen-Bradley, Listen. Think. Solve., and Rockwell Software are trademarks of Rockwell Automation, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies. Publication MIGRAT-PP017B-EN-P April 2015 Supersedes Publication MIGRAT-PP017A-EN-P September 2015 Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.