Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective



Similar documents
Protection and Substation Automation. Training Programmes

Substation Automation Systems. Nicholas Honeth

Substation Automation based on IEC 61850

IEC 61850: Communication Networks and Systems in Substations

Industrial IT for Substation Automation & Protection

B5-103 DESIGN OF IEC BASED SUBSTATION AUTOMATION SYSTEMS ACCORDING TO CUSTOMER REQUIREMENTS

Substation Automation and Smart Grid

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

DIGITAL CONTROL SYSTEM PRODUCT SOLUTIONS

SCOPE OF WORK - SUBSTATION

Permissible ambient temperature Operation Storage, transport

IEC in ZX Gas-insulated medium voltage switchgear

Grid Automation Products. MicroSCADA Pro for substation automation

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

INTELLIGENT SWITCHGEAR AND INFORMATION TECHNOLOGY

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

1. Introduction Communication in Substation

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

Basics in Energy Information (& Communication) Systems Substation Automation

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

Basics in Energy Information (& Communication) Systems Summary Substation Automation

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

A MODERN DISTRIBUTION MANAGEMENT SYSTEM FOR REGIONAL ELECTRICITY COMPANIES

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

HYDRO-ELECTRIC POWER PLANTS

ABB PSPS Erich Steinmann; Generator control-2013

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Chapter 1. Network Structures

Implementation of a New Substation Restoration System Using Protective Relays and a Logic Processor

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

Square D Model 6 Motor Control Centers

Paralleling Switchgear

Eaton s E-Series protective relay family

SCADA. The Heart of an Energy Management System. Presented by: Doug Van Slyke SCADA Specialist

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

GROUP OF SPANISH ELECTRICITY COMPANIES FOR STUDIES ON IEC 61850

Power network telecommunication

Internet-Accessible Power Monitoring & Control Systems

Introduction To SCADA and Telemetry

Substation Automation Using IEC61850 Standard

Remote Monitoring and REC 501 Control Unit Product Guide

Siemens ENEAS solutions for substation automation and protection

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Voltage Regulator SPAU 341 C. Product Guide

Evolution of Control for the Smart Transmission Grid

SCADA Questions and Answers

Power products and systems. Intelligent solutions for power distribution Zone concept

Challenges of Protection and Control System Verification on DP3 vessels with Focus on Ride Through Fault and Blackout

Trip circuit supervision relay. Type RXTCS

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Test & Data Management Software

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

Technology Solution Guide. Deploying Omnitron PoE Media Converters with Aruba Access Points and AirMesh Routers

Monitoring & Control of Small-scale Renewable Energy Sources

Feeder protection. for overhead lines and cables in isolated neutral or compensated networks. Specification

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

TDMS Test & Data Management Software

ABB North America. Substation Automation Systems Innovative solutions for reliable and optimized power delivery

Welcome. Enabling Wide Area Monitoring, Protection, and Control (WAMPAC) Systems with and the Importance of Time Synchronization

Latest Power Plant Control System

Distribution System Automation

Comprehensive Range of Industrial Products and Solutions

ABB RTU560A Series CMU & Modules

PIPELINE ENGINEERING - Pipeline System Automation and Control - C. Bruce Warren and Mike S. Yoon PIPELINE SYSTEM AUTOMATION AND CONTROL

T Substation Maintenance and Commissioning Test Equipment

Performance of Redundant Ethernet Networks for Electric Substation Instrumentation and Control

SCADA System Fundamentals

Engineering Specification

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

Power Industry Communication Protocol Features and Benefits

Substation Communications Design - Legacy to IEC 61850

SMS GSM Alarm Messenger

Disturbance Recoder SPCR 8C27. Product Guide

English Training RTU / Substation Automation MicroSCADA Courses 2012 ABB DEPSNM-T ( )

CLASS Voltage Regulation Scheme. 27 February 2014

SCADA and Monitoring for Solar Energy Plant

EVALUATION OF ALTERNATIVE BACKUP PROTECTION SCHEMES ON A 66KV DISTRIBUTION NETWORK

Minimizing Impact of Electric Utility Outages with Backup Generation

Everything you need for protection scheme testing

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Table of Contents. TransformerIQ FAQs 1

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

Mladen Kezunovic Texas A&M University

GE DigitalEnergy. Integrated Substation Control System (iscs) IEC based Substation Automation Solutions

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

FOXBORO. I/A Series SOFTWARE Product Specifications. I/A Series Intelligent SCADA SCADA Platform PSS 21S-2M1 B3 OVERVIEW

E-Series protective relay family

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

This webinar brought to you by the Relion product family

GST301. (Single Protection Zone) Operation Manual

CYBER SECURITY: SYSTEM SERVICES FOR THE SAFEGUARD OF DIGITAL SUBSTATION AUTOMATION SYSTEMS. Massimo Petrini (*), Emiliano Casale TERNA S.p.A.

Temperature & Humidity SMS Alert Controller

GSM ATT Modules Simply effective remote control

Relion 611 series. Feeder Protection and Control REF611 Application Manual

Transcription:

Technical Specification Of Substation Protection & Control System with IEC 61850 BHEL s Perspective India Core Events 2008 September 24 th 2008 1

Background Stability & Reliability Data Storage Communication Facilities 2

Numerical Relays Data Storage Communication Capabilities Instrumentation Programmable Logic Self Supervision Multiple Setting groups Multiple Characteristics 3

Changing Scenario Conventional Control & Protection RTU based SCADA with backup Mimic IEC 61850 based Substation Automation System 4

IEC 61850 Interoperability Free Allocation of Function to devices Insulation from Changes in Communication Peer to Peer Communication 5

Comparison Of Features Function Conventional Control Panel and Protection Panel RTU based SCADA, Backup Mimic Board Panel and Conventional Protection Panel IEC 61850 based Substation Automation System (Control & Protection) Mimic Central Control Panel SCADA HMI and Backup Mimic Board HMI of Substation Automation System (SAS) Control Breaker and Isolator Control Switch SCADA HMI and Miniature Discrepancy Switches on Backup Mimic Board SAS HMI and BCU Circuit Breaker Synchronising Synchronising Trolley with Synchroscope & Check Synchronising Relay Check Synchronising Relay and Synchronising Trolley with Synchroscope on Mimic Panel Check Synchronising Function in BCU. Hand held Synchroscope where BCU panel is in same room as HMI 6

Comparison Of Features Function Conventional RTU SAS Indication Semaphore and Indicating Lamp SCADA HMI and Miniature Discrepancy Switches on Backup Mimic Board SAS HMI and BCU Indicating Metering CT/VT or Transducer driven Indicating Meters SCADA HMI and Multifunction meters SAS HMI and BCU Interlockin g of Isolator, Earth Switches Hardwired Interlocks Software interlocking with Backup Hardwired Interlocks. Software interlocking at BCU level using information from other BCUs through GOOSE Message. 7

Comparison Of Features Function Conventional RTU SAS Alarm Management Alarm Facia Event Logger Independent Event Logger Disturbance Independent Recorder Disturbance Recorder with own LAN SCADA HMI and Alarm Facia on Backup Mimic Board SCADA HMI Independent Disturbance Recorder with own LAN. Engineering Work Station connected to BPUs through dedicated network. SAS HMI SAS HMI SAS Engineering Work Station connected to BPUs through IEC 61850 LAN. Protection Single or Multiple functions in single device. Multiple functions in single device. Concept of Logical Device and Physical Device. Multiple functions in single device. Single functions in multiple device using GOOSE messaging. 8

9

Comparison Of Features Function Conventional RTU SAS Historical Data Manangement, Analysis Remote interface with Load Dispatch Centre (LDC) Power Plant Distributed Control System (DCS) Interface NIL SCADA SAS Communication independent RTU with Hardwired through potential free contacts and transducer outputs Communication SCADA or RTU with Hardwired through potential free contacts and transducer outputs Communication through Gateway Communication through Gateway 10

Comparison Of Features 11

IEC 61850 Implementation in India PGCIL - 400kV Swyd 1 1 / 2 CB scheme With remote comn NTPC 400kV Swyd 1 1 / 2 CB scheme with remote & DCS DVC 400kV 2M+T Scheme with remote & DCS MSEB - 400kV Swyd 1 1 / 2 CB scheme TNEB 400kV Swyd 1 1 / 2 CB scheme, 220kV- 2M Pragati Power Corp Ltd - 400kV Swyd 1 1 / 2 CB scheme 12

IEC 61850 Specs in India Features POWERGRID Specification NTPC Specification Scope of BCUs EHV System Electrical Auxiliary System (415 V ac and 220/48V dc System) Mechanical Auxiliary system (Airconditioning and Physical Architecture The Fire BCUs, Fighting) BPUs and PLCC Panels are located close to the process in Air-conditioned Kiosk. LAN extends to the switchyard. Control and monitoring is limited to EHV System. It does not extend to Electrical or Mechanical Auxiliary System. Of switchyard The BCUs, BPUs and PLCC Panels are located in the Centralised Control Room. LAN does not extend to the switchyard, Instead it extends to Main Plant Control Room. 13

IEC 61850 Specs in India Features POWERGRID Specification NTPC Specification Local Area Network (LAN) Redundancy Bay to Bay - Fibre Optic LAN Sub-Station Network - Fibre Optic LAN Communication shall be in 1+1 mode except link between IED to Ethernet switch, such that failure of one set of fibre shall not affect the normal operation Redundant of the SAS. HMI Bay to Bay - Fibre Optic LAN Sub-Station Network - Cat-5 Shielded UTP Cable or Fibre Optic. Fibre Optic LAN for distance >50m, between rooms and between buildings. Communication shall be in dual redundancy configuration. No single failure of any component/module of SAS including communication link shall cause loss of functionality of more Redundant than one bay. HMI at switchyard and one HMI at Power Plant 14

IEC 61850 Specs in India Features HMI Specification Gateway for Remote Control & Monitoring No. Of BCUs POWERGRID Specification 21 Visual Display Unit (VDU) 1280x1024 Regional System pixels Co-ordination Centre Remote Control 1 per Centre Bay. Bay defined as CB. NTPC Specification Visual Display Unit (VDU) and Rear Projection Display (2m x 1.5m) Power Plant Distributed Control System (DCS) Remote Load Dispatch Centre 1 per Bay. I/O Requirement for BCUs As per Actual Utilisation & 200 numbers spare inputs. Minimum I/O specified per bay Binary Input - 64 Binary Output 24 Analog Input 16 15

IEC 61850 Specs in India Features Interlocking POWERGRID Specification All interlocks are software based using Goose. Station Level Interlocks are also Hardwired (e.g. Bus Display Earth Not specified Switch). Response Time NTPC Specification All interlocks are software based using Goose. Station Level Interlock are in two BCUs (e.g. Bus Isolator, Earth Switch, Bus Coupler) 1.5 sec Duty Time Cycle Not specified 40% free time over 2 sec period 60% free time over 1 min period Inter-bay bus and substation network spare duty Not specified 50% free time over 2 sec period 16

IEC 61850 Specs in India Features Analog updation value POWERGRID NTPC Specification Specification 2 sec Not specified Alarm Event Tag and 1 milli-sec Not specified Auto-reclose (AR) AR is a control function and can be a part of BCU. Autoreclose function in BCU with Goose messaging from Distance relays offers an elegant solution for both Main and Tie CB. 220 & 132kV system AR can be a part of BPU AR is a protection function. 400 & 220 kv system AR can be a part of both Main 1 & 2 BPU. Hardwired signals are preferred. 132kV system and below AR can be a part of BPU AR for Tie CB, TBC CB has to be standalone. 17

IEC 61850 Specs in India Features Busbar Protection POWERGRID Specification Duplicated Busbar protection for 400kV system. NTPC Specification Duplicated Busbar protection for each bus with different CT cores is provided in 400kV system. 220/132kV system - Check zone with different CT core is not specified. However, check function is implemented in main LBB Protection Busbar Generally protection inbuilt relay. feature of Busbar protection. Single standalone relay for Tie Breakers. One main protection for each bus with common check zone for both buses with common check zone connected to different CT core for 220/132kV system. Generally inbuilt feature of Busbar protection. duplicated LBB scheme for all Breakers irrespective of inbuilt or standalone Relay 18

BHEL RECOMMENDATIONS Control Functionality Level 4 Remote Control Centre (RLDC) Status Indication and Metering Level 3 Remote Control Centre (Remote Sub-station) Full Functionality Level 2 Substation Level (HMI of SAS) Level 1 Bay Level (BCU, BPU) Level 0 Equipment Level (CB, Isolator, Transformer) 19

BHEL RECOMMENDATIONS Control Functionality BCU Per Bay / Per Feeder Basis Analog Inputs Clarity : - VT Inputs ( Metering ) 4 CT inputs 4 VT Inputs ( Synch) 1 Transducer Inputs for WTI,OTI, Tap Position Transformer Monitoring Relay with Tap Changer Control, Tap Position Status, Automatic Voltage Control Replace RTCC Panels 20

BHEL RECOMMENDATIONS Control Functionality for Aux Systems Aux BCU For Station Aux System 415 V AC, 220V DC & 48 V Dc Remote Control for Incomers, Bus Sections & Bus Coupler 21

BHEL RECOMMENDATIONS Redundancy 22

BHEL RECOMMENDATIONS Interlocking All Bay Level Interlocks to be in BCU Inter bay interlocks through GOOSE Station Level Interlocks in Redundant BCU 23

BHEL RECOMMENDATIONS Interlocking 24

BHEL RECOMMENDATIONS Goose Implementation Present Implementation by BHEL Alarms from BPU to BCU Isolator / ES interlocking CB Closing interlocking ( 86 & 96 ) Relay Supervision DR Triggering in M1 from M2 General Trend to Implement Goose in Control And Hardwiring for Protection. Time to replace Faith in Wiring to Faith in LAN 25

BHEL RECOMMENDATIONS Goose Implementation Some Suggestions Auto Reclose Initiation Voltage Selection for CB Synchronisation LBB Initiation Switchyard equipment status for DR 26

BHEL RECOMMENDATIONS Goose Implementation 27

BHEL RECOMMENDATIONS Goose Implementation 28

BHEL RECOMMENDATIONS Control Commands Select before Operate ( SBO) For CB, ISO Operation Selection Execution De-selection Automatic Select Before Operate Many ( SMO many ) For Transformer tap change operation Selection Execution ( repeatative ) De-selection Direct Execute Mode Control Without any Selection ( e.g. Trip Relay Reset ) 29

Future Developments Process Bus Currently, primary equipment data models are implemented in BCU as Logical Node XCBR for CB, TCTR for CT, TVTR for VT. In Future, SAS will interact with Merging Unit (MU) and Circuit Breaker Controller (CBC) Merging Unit works acts as digital interface between BCU/BPU and primary equipment (CT, CVT). Standards : IEC 60044-8, IEC 61850-9-1 Controller acts as Digital Interface for Switchgear. Circuit Breaker Controller (CBC) & Disconnector Controller (DSC) 30

AC KIOSKS 31

32

System Architecture (POWERGRID) 33

ABB IMPLEMENTATION 34

SIEMENS IMPLEMENTATION 35

Remote Control Centre(s) IEC60870-5-101 SWYD Control Room IEC60870-5-104 Rear Projection MIMIC Display GPS Substation Network A TO SH 2/2 IEC60870-5-104 Substation Network B TO SH 2/2 Engineer Office 2x 2x Engineering & Fault Recorder Station Printer SWYD Network Main Controller Operator Workstation Printer Printer SWYD Network Standby Controller Operator Workstation (Heartbeat) Communication: IEC61850 protocol Communication: IEC61850 protocol 400 kv Interbay Bus A 400 kv Interbay Bus B Engineering Bus (OPTIONAL) To DR workstation IEC60870-5-103 IEC60870-5-103 BCU BPU BPU Option 1 Bay 1 BPU Sec Bay 2 BPU primary Option 2 LEGEND: BCU Bay Control Unit BPU Bay Protection unit Notes: DFR DISTURBANCE Recorder 1. The substation controllers and operator workstations are fully redundant 2. The SWYD Interbay bus shall be a dual redundant, star or ring topology, fibre optic bus. 3. All data connections between rooms or buildings shall be via fiber- optic. 4. The BCU includes mimic display, analogue and status indications, alarm annunciation, local control, and inter-bay communication for local control with interlocking 5. All BCU, BPU, Controllers, Workstations synchronized to GPS reference time 6. Two IEC60870-5-101 ports shall be provided to interface to control centre(s) BCU Stand alone DFR (optional) Engineering Workstation (portable) DRN DGN CHKD APPD DATE BCU BPU Bay n-1 Option 1 BPU BCU Bay n BPU PRIM Option 2 FOR TENDER PURPOSE ONLY BPU SEC PROJECT BARH STPP- SWITCHYARD TITLE - SUBSTATION AUTOMATION SYSTEM ARCHITECTURE DRG. NO. 9558-572-POE-A-006- SH 1/2 REV. B 36

FROM SH 1/2 FROM SH 1/2 Substation Network A GPS Substation Network B Operator s Workstation Printer SWYD Network Main Controller Main Plant Engineering cum Fault Recording Station Gateway for Connectivity to Owner s OPCcompliant DCS Communication: Preferably IEC61850 protocol GENERATOR CIRCUIT LAN (OPTIONAL) ENGINEERING BUS NUMERIC AL RELAY 1 BPU FOR GEN-1 (660MW) NUMERICAL RELAY 2 DFR FOR GEN-1 NUMERIC AL RELAY 1 NUMERICA L RELAY 2 BPU FOR GEN-2 (660MW) DFR FOR GEN-2 NUMERIC AL RELAY 1 NUMERICA L RELAY 2 BPU FOR GEN-3 (660MW) DFR FOR GEN-3 Engineering Workstation (portable) CENTRAL CONTROL ROOM ( 3X660MW) FOR TENDER PURPOSE ONLY DRN DGN CHKD APPD DATE PROJECT BARH STPP- 400/132 kv SWITCHYARD TITLE - SUBSTATION AUTOMATION SYSTEM ARCHITECTURE DRG. NO. 9558-572 - POE-A- 006 SH 2/2 REV. A 37

Areva Implementation 38

System w/o Process Bus 39

System with Process Bus 40

Cost Impact of IEC 61850 Implementation For SAS Conventional IEC 61850 System System Control Building ( with AC Kiosk ) X X- 35Lakhs Illumination & ACVS X X-35 Lakhs Control System X X + 125 Lakhs Cable Trenchs X X-7 Lakhs Cables X X- 95 Lakhs 41

42