Syphonic Roof Drainage



Similar documents
Syphonic Roof Drainage

Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.

3. Geberit Pluvia Roof Drainage Systems

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

Puddle Flange. FRANK Puddle Flange

Pipe Clamps and Accessories

Saferand easierinstallation

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

A WATERTIGHT SYSTEM. In a nutshell: a system that fully meets present-day requirements.

MAXFLOW SYPHONIC DRAINAGE SYSTEM

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Pluvia Product and Installation Guide

Flue Installation. High Efficiency Condensing Boilers

Fire Collars For Plastic Pipe Penetration

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

ROOF DRAINS TABLE OF CONTENTS

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

ISSUE 08/08. KEEP INFORMED Look for other Good Idea Leaflets that could help you with your current project.

Soil and waste for high-rise

DYKA BV P O Box 33 NL-8330 AA Steenwijk Netherlands Tel: Fax: info@dyka.com website:

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

Colonnade Security Pipe

BIS WC Element / Lyft Alpro

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

Welcome: What is U Drain? Drain Materials. Flow

Window Installation Instructions

Installation instruction CASAFLEX - Connecting piece DN 100

14. Tools and Software

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Composite Panel Firewall Systems

BOQ for Plumbing, Sanitary Works

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

Coolflo Safe Touch Shower Mixing Valve ST20015CP


WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

Drive shaft, servicing

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

GPD Rubber Press Seals

ACO Water Management: Civils + Infrastructure

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

WATER SERVICE 2

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Sports Buildings: budget costs for the Flood Relief Fund

Drainage Systems Installation Guide

Destiny Shower Enclosure Installation Instructions

TECHNICAL SPECIFICATION

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

Mechanical Services Standard Specification Above Ground Soil, Waste and Ventilation Pipes

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

plumbing products guide

STATE BANK OF INDIA.

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Mechanical Services Standard Specification Compressed Air Systems. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

swimming pool accessories

4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.

Geberit Pluvia Syphonic roof drainage system. Stands up to every kind of rainfall

Multiport Spill Containment with Defender Spill Containers

opti-drän system Keeps your basement and building dry

8.7 Schluter -KERDI-LINE

Important Information

Epdm Flat Roofing Systems

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

Packaged Terminal Air Conditioner Wall Sleeve Installation

SECTION FACILITY STORM DRAINAGE PIPING

MAXFLOW DRAINAGE SYSTEM MAXFLOW SYPHONIC DRAINAGE SYSTEM

Select Radiators Installation Guide

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Operating Instructions

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

BB-18 Black Body High Vacuum System Technical Description

kymanual or Automatic - it s your Choice

frostdrainage.com Floor Drains & Rodding Eyes

IMPORTANT INFORMATION

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

CRN A-F-G-E-HQQE 3x400D 50 HZ

Fiberstars Mini Lighted Laminar Flow Fountains

ACO Water Management: Civils + Infrastructure

Passive Fire Protection

SELECTION, APPLICATION & MAINTENANCE

Reticulation sewers in basements Technical guidelines

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

FIX TURE CARRI ERS. 140(a) MPB-2011-USA

Installation Instructions

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Transcription:

Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology

Geberit Syphonics Geberit Pluvia is the leading syphonic roof drainage system used throughout the world. Architects, Consultants and Contractors have Examples of the 3 Outlet Types Available (See following pages for other variations of outlet) Series 7 (max 12l/s capacity) Series 7 Outlet in a Steel Profile Roof Deck (without Vapour Barrier Clamping unit) chosen the system for some of the most prestigious and ground breaking building Joint foil to suit membrane (see page 3) Pluvia Outlet 359.551.00.1 Roof Membrane Thermal Insulation Vapour Barrier designs due to the freedom and flexibility it provides. Pluvia uses the ingenious gravity induced vacuum principle to create a syphonic action, which allows the complete drainage of a roof area with smaller diameter pipes than used in a conventional gravity system. Geberit Pluvia Advantages No slope in pipework required Less underground pipe Less sitework Fewer pipes and fittings Steel Roof Profile Decking 90 0 Bend Electroweld Coupling and Brackets (Creating on Anchor Point) Geberit Pluvia Rail System Series 7+ (max 25l/s capacity) Series 7+ 25 Litre Outlet in a Concrete Slab Roof Pluvia Outlet 359.502.00.1 Geberit PVC Coated Outlet Flange bonded to PVC Roof Membrane (This outlet is also available without PVC coating 359.573.00.1 for other roof finishes Reduced pipe dimensions Less space required Self cleaning action Quick and easy fastening system The only system to be fully BBA Accredited Concrete Slab 90 280 Series 5 (max 6l/s capacity) Series 5 Outlet - 56mm(6 L/s) with PVC Roof Finish Pluvia Outlet 359.501.00.1 Geberit PVC Coated Outlet Flange bonded to PVC Roof Membrane CD-ROM available with installation details of various outlets and roof configurations. Concrete Slab 15mm max 56 214 1

Outlets Series 7 290 95 325 20 0-130 100-230 315 60-220 d 350 Pluvia basic outlet without insulation block 359.563.00.1 Pluvia retrofit promenade top element 359.635.00.1 290 0-130 d 295 95 70 100-230 0-150 320 290 95 70 100-250 Pluvia basic outlet with insulation block 359.551.00.1 Pluvia gutter outlet 359.636.00.1 Stainless 359.637.00.1 Copper 359.638.00.1 Aluminium d 295 290 d 95 115 210 Pluvia horizontal outlet 325 20 359.565.00.1 315 60-220 70 0-130 100-230 0-130 7 100-230 56 295 350 d 295 Pluvia base element 359.631.00.1 Pluvia promenade outlet 359.562.00.1 2

Outlets Series 7 290 Jointing Foils and Flanges for Series 7 Outlets 359.571.00.1 0-130 0-150 56 295 520 290 56 295 40-180 Pluvia 2 tier outlet (lower element for sealing penetration through vapour barrier) 359.550.00.1 Pluvia outlet incorporating a stainless steel flange 95 70 100-230 95 70 100-250 359.556.00.1 Series 7 320 x 320 Aluminium Contact Sheet 359.555.00.1 Series 7 320 x 320 Copper Contact Sheet 359.554.00.1 Series 7 320 x 320 S/S Contact Sheet 359.592.00.1 Series 7 500 x 500 Contact Foil EPDM Hertalan 359.588.00.1 Series 7 500 x 500 Contact Foil EPDM Novotan 359.577.00.1 Series 7 500 x 500 Contact Foil EPDM Resistit 359.589.00.1 Series 7 500 x 500 Contact Foil Evalon Alwitra 359.578.00.1 Series 7 500 x 500 Contact Foil Liquid Bitumen 359.603.00.1 Series 7 500 x 500 Contact Foil PVC Alkor 359.586.00.1 Series 7 500 x 500 Contact Foil PVC P Rhenofol 359.587.00.1 Series 7 500 x 500 Contact Foil PVC Protan 359.579.00.1 Series 7 500 x 500 Contact Foil PVC Sikaplan/Trocal 'S' PVC 359.950.00.1 Series 7 500 x 500 Contact Foil PVC Trocal SGmA PVC 359.576.00.1 Series 7 500 x 500 Contact Foil Sarnafil FPO-A TG55-20 359.575.00.1 Series 7 500 x 500 Contact Foil Sarnafil PVC 9917.500 Series 7 500 x 500 Contact Foil Permaquik 359.560.00.1 Series 7 520 x 520 Contact Sheet Stainless Steel 359.568.00.1 Series 7 Contact Clamping Flange 359.593.00.1 Series 7 500 x 500 Contact Foil PE C Alkor 359.558.00.1 Series 7 600 x 600 Installation Sheet 80 Series 7 outlet overflow adaptor 6147/DVW 82 129 Seal Ring (Push fit into outlet) Not supplied with Overflow Adaptor Remove function disk from outlet and discard when using this adaptor Pluvia outlet contact flange 359.568.00.1 36 29 9 5 Outlet Grating (spare) 359.561.00.1 3

Outlets Series 7+ 320 55 90 280 150 75 24 litre Pluvia outlet stainless steel (without flange) 359.544.00.1 23 600 320 90 280 45 85 160 Extension piece 56mm (Series 5) 359.604.00.1 Flanged 24 litre Pluvia outlet 359.573.00.1 All stainless 359.502.00.1 PVC coated stainless 500 200 Series 5 110 Waterproof flanges (Series 5) 359.612.00.1 Bitumen 359.610.00.1 Sarnafil PVC 359.618.00.1 PVC Sika Can only be used with 359.604.00.1 480 Flanged 6 litre pluvia outlet 56 170 359.500.00.1 All stainless steel 359.501.00.1 PVC coated stainless steel 79 145 25 Spare Parts Series 5 Clamping ring 359.512.00.1 56mm 215 110 Gravel ring 359.511.00.1 56mm 70 135 6 litre Pluvia outlet (without flange) 359.514.00.1 All stainless steel 56 170 25 Grating 359.510.00.1 56mm 4

Pluvia Rail and Fixing System Steel square pipe (5m length) (electro-galvanised) 362.863.26.1 Steel square pipe connection element (electro-galvanised) 362.864.26.1 Guide brackets steel (rail only) (electro-galvanised) pipes Ø 40mm 360.861.00.1/2 Ø 50mm 361.861.00.1/2 Ø 56mm 363.861.00.1/2 Ø 63mm 364.861.00.1/2 Ø 75mm 365.861.00.1/2 Ø 90mm 366.861.00.1/2 Ø 110mm 367.861.00.1/2 Ø 125mm 368.861.00.1/2 Ø 160mm 369.861.00.1/2 Ø 200mm 370.861.00.1/2 Clamp for steel square pipe (electro-galvanised) 362.862.26.1 Pluvia rail support angle bracket (electro-galvanised) G90.960.00 Support shells, galvanised inside with black painted finish (3m length) (use cable ties to secure to pipe) d(mm) 40 360.850.00.1 50 361.850.00.1 56 363.850.00.1 63 364.850.00.1 75 365.850.00.1 90 366.850.00.1 110 367.850.00.1 125 368.850.00.1 For HDPE pipework,fittings and tools please refer to the Geberit Drainage System Product and Price Guide. Tension wedge for sliding and anchor bracket (electro-galvanised) 362.865.26.1 Mounting plates (electro-galvanised) 1/2 362.826.26.1 1 362.828.26.1 Electroweld Tapes ød 50 361.776.16.1 56 363.776.16.1 63 364.776.00.1 75 365.776.16.1 90 366.776.16.1 110 367.776.16.1 125 368.776.16.1 160 369.776.16.1 200 370.776.16.1 250 371.776.16.1 315 372.776.16.1 Electroweld tapes are an alternative method of creating an anchor point, see page 7 for details. 5

Pluvia Rail System The Geberit Pluvia rail system was developed for the installation of horizontal pipework. Advantages of the rail system Quick installation Fewer ceiling fastening points Controls thermal movement No expansion because of rigid installation No expansion sockets in the horizontal pipes Simple prefabrication is possible One fastening for anchor and sliding brackets The expansion and contraction of the pipework is prevented by the rail system, the properties of HDPE allows rigid fixing. G90.960.00 Pluvia Rail Support Angle Bracket Allows T connections using single studding drop Locks rail together providing a true anchor point Quick and easy to install Pluvia Rail 362.863.26.1 Threaded Rod M10 Tension Wedge 362.865.26.1 Pluvia Bracket Connector to Rail 362.864.26.1 Rail Clamp 362.862.26.1 6

Brackets and Anchor Points HORIZONTAL PIPE-WORK (PLUVIA) BRACKETING DETAIL 2.5m PLUVIA RAIL SYSTEM METHOD 2.5m A A A (ANCHOR POINT) RA GUIDE BRACKET PLUVIA RAIL BRACKET AND DROP ROD 5m max RAIL RAIL CONNECTOR ELECTROWELD COUPLNG (ANCHOR POINT Pipe bracket spacing Pipe Weight (full of water) With shells Without shells With shells Without shells Pipe Ø d mm RA m RA m FG at A N FG at A N 40 1.0 0.8 72 70 50 1.2 0.8 92 88 56 1.2 0.8 92 107 63 1.2 0.8 112 129 75 1.6 0.8 162 156 90 1.3 0.9 211 203 110 1.6 1.1 300 279 125 1.8 1.2 372 348 160 2.4 1.6 658 628 FG - Weight of fully filled system at A with spacing adhered to. RA CONVENTIONAL BRACKETING METHOD (Supplied by Others) ELECTROWELD COUPLNG (ANCHOR POINT) 5m max GUIDE BRACKET ELECTROWELD COUPLNG (ANCHOR POINT) 7

Brackets, Anchor Points and Expansion Methods of creating fixed and sliding supports Anchor Point Anchor Point Anchor Point Sliding Clamp Anchor Point HORIZONTAL OR VERTICAL Using conventional fixing Anchor Point HORIZONTAL Using Geberit Rail System See application guide of HDPE system for diameter of fixing stud VERTICAL Instruction for expansion joint method The following conditions are important to ensure perfect and easy assembly of the sleeve: 1. Chamfering the inserted pipe end to approximate 15 2. Check the scale on the outer surface of the expansion socket for insertion depth. 3. Mark the correct insertion depth on the pipe. 4. Lubricate the pipe end well with soft soap, Silicone or Vaseline. N.B. Do not use oil or grease which can damage the rubber seal. Table A Dia mm Vert. m 32 40 50 56 63 75 90 110 125 160 200 250 315 1.2 1.2 1.2 1.5 1.5 1.5 2.0 2.0 2.0 2.0 2.0 3.0 3.0 Ø Max. 6m Using expansion joints Expansion Joint For spacing between guide bracket see table A Expansion Joint Example: Insertion depth in an ambient temperature or 20 C (vertical assembly) Rigid fixing Anchor point with electroweld tape Max. 6m Fixings must be strong enough to resist forces of thermal expansion (See application guide for HDPE for data) Sliding brackets Fixings must be strong enough to resist forces of thermal expansion (See application guide for HDPE for data) Anchor point with electroweld tape For spacing between guide bracket see table A 8

Pluvia Termination and Connection 1 4 A B Pluvia conventional Pluvia A B 2m minimum Below floor slab Minimum distance before manhole 2 Pluvia 5 A Pluvia conventional Above floor slab B Open Pluvia systems are not permitted Allowable reductions in pipe diameters 3 Horizontal collection pipe B Pluvia A conventional After sealed access in manhole Reduction in pipe by one size permitted A To break the syphon diameter of pipe to be a minimum of 2 sizes larger than Pluvia pipe B Underground drainage to be sized to prevent surcharging Vertical RWP 9

Maintenance Geberit recommend that a maintenance programme is always implemented on completion of the project. The intervals between inspection will depend on the location of the building. The maintenance programme should include:- 1 2 3 Clearing of all outlets of any debris or silt as shown in figure 1. a Remove lid b + c Remove function disc d Rinse function disc with water Check that no pipes connecting to outlets are blocked with silt etc, if blockages are found they can be removed by using a water jet through the outlet after removing the top unit and function plate (a, b & c in figure 1) Ensure all outlets have gratings and tops in place. `order spares from Geberit if necessary. e Wipe outlet with cloth d a c b b e Figure 1 Testing of System On completion of a Geberit Pluvia System the integrity of all joints must be tested using an air test as described in BS EN 12056, which in general requires a 38 mm air test for 3 minutes. If the installation has been designed using the Geberit software it is not normally necessary to performance test the installation. Third party approval by the BBA included verification that the software is a true reflection of the actual flow performance. 10

A D V A N C E D P L U M B I N G T E C H N O L O G Y Other Geberit Syphonic literature available: Design guide Other innovative products available within the Geberit Ltd. product portfolio include: Geberit Terrain UPVC & HDPE soil, waste and underground drainage systems Geberit Mepla water supply Geberit Terrain Rainwater Systems Geberit Duofix wall hung sanitaryware installation systems, WC and urinal flushing systems, electronic washroom solutions and shower toilets Please call 0700 4323748 or visit www.geberit.co.uk for more information. Geberit Ltd. New Hythe Business Park New Hythe Lane Aylesford, Kent ME207PJ Tel:+44 (0)1622 717811 Fax:+44 (0)1622 716920 www.geberit.co.uk Registered office as postal address Registration Number 761885 SYPHONICS