1 Pluvia Prouct an Installation Guie Vali from 1. August 2011

2 Series 5 Pluvia outlets Page 3 Series 5 Outlet accessories Page 4 Series 7 Pluvia outlets Page 4 Series 7 Pluvia accessories Page 9 Series 7 Pluvia spares Page 11 Series 7+ Pluvia outlets Page 13 PluviaFix Brackets Page 15 Prouct Guie PluviaFix square profile rail system Page 17 PluviaFix pipe brackets with threae fastening Page 18 PluviaFix C profile track system for pipe iameters Page 19 Mounting plates Page 20 Electrofusion tape for anchor bracket Page 22 PluviaFix support sets Page 23 PluviaFlex Page 24 Installation Guie Page 27 Numerical Inex Page 39 Pluvia Prouct an Installation Guie

3 Prouct Guie Introuction Geberit Pluvia is the leaing siphonic roof rainage system use for over 30 years aroun the worl in over 80,000 installations to rain 80 million sq metres through 300,000 outlets. Architects, Consultants an Contractors have chosen the system for some of the most prestigious an groun breaking builing esigns ue to the freeom an flexibility it provies. Pluvia uses the ingenious gravity inuce vacuum principle to create a siphonic action, which allows the complete rainage of a roof area with smaller iameter pipes than use in a conventional gravity system. Geberit Siphonic roof systems are wiely use in the inustrial an coercial sector for all roofs. Geberit Pluvia Avantages: New architectural flexibility in builing an use No slope in pipework require Less unergroun pipe work Less sitework Fewer pipes an fittings Reuce pipe imensions Less space require Self cleaning action A simple an speey fastening system Conventional System Siphonic System Pipe Fall Fall 1-3 % No Fall Necessary Down Pipes Many Down Pipes Fewer Down Pipes Unergroun Pipes Long Unergroun Pipes Short Unergroun Pipes The Geberit Pluvia System is fully approve by the BBA. This inclues outlets, pipes & fittings, an the eicate esign software. All installations carry a minimum of a ten year prouct liability guarantee, an must be carrie out by a Geberit Pluvia approve installer. The prouct range inclues outlets to suit most roof esigns an finishes, with a comprehensive range of contact foils to suit the majority of roof membrane materials currently on the market. RIBA approve CPD seminars are available. Please contact Geberit for more information. 2 Pluvia Prouct an Installation Guie 2011

4 Prouct Guie Pluvia outlets Series 5 Pluvia Series outlets 5 Series 5 Pluvia outlets Flange 6 litre Pluvia outlet stainless steel Drainage capacity max. 6 l/s Article no. PU1 PU litre Pluvia outlet (without flange) stainless steel h D h1 H 1 K For installation in gutters mae from chrome-nickel steel Drainage capacity max. 6 l/s Outlet grating; Protection housing Article no. Ø 1Ø D cm H cm ,5 13, , h cm h1 cm K cm PU1 PU4 Pluvia Prouct an Installation Guie

5 Prouct Guie Series 7 Series 5 Outlet accessories / Series 7 Pluvia outlets Series 5 Outlet accessories / Series 7 Pluvia outlets Series 5 Outlet accessories Series 5 gravel ring Series Pluvia outlets 7 Series 7 Pluvia outlets Series 7 Pluvia outlet with clamping ring, universal for plastic membranes Prouct material Stainless steel Article no. PU Series 5 clamping ring For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection of plastic roof membranes Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Maintenance free clamping flange connection Drainage capacity min. Drainage capacity max. Height of aing 1 l/s 12 l/s 35 Article no. PU Series 5 grating Outlet grating with operating part; Outlet connection flange with seal an nuts; Base unit with integrate outlet isk mae of metal; Conensation protection Article no. Ø PU1 PU Spare part for Pluvia series 5 ø 56 Prouct material PP Article no. Ø PU Pluvia Prouct an Installation Guie 2011

6 Prouct Guie Pluvia outlets Series 7 Series 7 Pluvia outlet with clamping ring for bitumen roofs Geberit Pluvia roof outlet, 12 l, 56, with punche contact sheet an bitumen roof foil For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with roof foils For connecting with bitumen roof foils Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Drainage capacity min. Drainage capacity max. Height of aing Bitumen roof outlet element, complete (base unit with integrate outlet isk, wele-on flange bolts, fastening flange, wing nuts); Insulation; Outlet grating with operating part Exclue: Protection box cover Article no. Ø PU1 PU l/s 12 l/s 35 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with bitumen roof foils Loa of the outlet grating < 150 kg Base unit with integrate outlet isc Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Bitumen roof sheet (SBS), flare at the factory, 4.5 Drainage capacity min. Drainage capacity max. Height of aing Base unit with integrate outlet isk mae of metal; Insulation against conensation; Outlet grating with operating part; Protective cap Article no. Ø PU l/s 12 l/s 35 Pluvia Prouct an Installation Guie

7 Prouct Guie Series 7 Series 7 Pluvia outlet with insulation block Series 7 Pluvia outlet without insulation block Pluvia outlets For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection with all kins of roof sealing material For insulate an non-insulate roofs Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection with all kins of roof sealing material For combining with the universal contact sheet Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Drainage capacity min. Drainage capacity max. Height of aing l/s 12 l/s 35 Drainage capacity min. Drainage capacity max. Height of aing Base unit; Outlet isk; Outlet grating with operating part; Insulation against conensation; Protective cap; Fastening material; Lubricants Article no. Ø PU1 PU l/s 12 l/s 35 Base unit with locking screw; Outlet isk; Outlet grating with operating part; Protective cap Article no. Ø PU1 PU Series 7 Pluvia outlet with stainless steel flange For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with bitumen roof foils Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Base unit with integrate outlet isc Drainage capacity min. Drainage capacity max. Height of aing 1 l/s 12 l/s 35 6 Pluvia Prouct an Installation Guie 2011 Base unit with integrate outlet isk mae of metal; Insulation against conensation; Outlet grating with operating part; Protective cap Article no. Ø PU1 PU

8 Prouct Guie Pluvia outlets Series 7 Series 7 Pluvia gutter outlet Series 7 Pluvia promenae outlet For collecting an raining of rainwater on roofs For siphonic roof rainage system For installation in gutters with a minimum of 35 cm with For connecting metallic materials Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Base unit with integrate outlet isc Drainage capacity min. Drainage capacity max. Height of aing Connecting material l/s 12 l/s 35 PE-HD Base unit with integrate outlet isk mae of metal; Insulation against conensation; Outlet grating with operating part; Protective cap Article no. Sealing of connection Ø PU1 PU Chrome-nickel steel Copper Peraluman For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with roof foils For inverte roofs For roofs with vegetation For weight-bearing roofs Do not use for roofs in which the maximum permitte loa on the grating (1500 kg) will be exceee Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Duct pipe can be shortene to a minimum of 4 cm Loa bearing capacity 1500 kg Duct pipe extenable by weling with corresponing spare part Drainage capacity min. Drainage capacity max. Height of aing l/s 12 l/s 35 Base unit; Outlet isk; Function isk; Insulation against conensation; Aitional set, weight-bearing; Protective cap; Fastening material; Lubricants Article no. Ø PU1 PU Pluvia Prouct an Installation Guie

9 Prouct Guie Series 7 Series 7 Pluvia horizontal outlet Pluvia 2 tier outlet (lower element for sealing penetration through vapour barrier) Pluvia outlets For collecting an raining of rainwater on roofs For siphonic roof rainage system Mainly for renovate roofs if an aitional thermal insulation is installe on the existing roof insulation For connection with all kins of roof sealing material For horizontal pipe connection Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Low installation height Loa of the outlet grating < 150 kg Drainage capacity min. Drainage capacity max. Height of aing 21 Base unit with horizontal outlet ø 56; Fastening material; Outlet isk; Outlet grating with operating part; Protective cap; Lubricants Article no. Ø PU1 PU l/s 6 l/s For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection with all kins of roof sealing material For connecting vapour barriers up to 3 thick Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Loa of the outlet grating < 150 kg Clamping ring with pull-out protection up to 120 kg Drainage capacity min. Drainage capacity max. Height of aing Base unit; Outlet isk; Outlet grating with operating part; Insulation against conensation; Loose flange; Protective cap; Fastening material; Lubricants Article no. Ø PU1 PU l/s 12 l/s 35 8 Pluvia Prouct an Installation Guie 2011

10 Prouct Guie Pluvia accessories Series 7 Pluvia accessories Series 7 Pluvia accessories Series 7 retrofit promenae top element Series 7 Pluvia overflow aaptor For later construction of roofs in the case of reverse roofs, accessible or green roofs For use with all Pluvia roof outlets 12 l Loa bearing capacity 1500 kg Grating; Frame of grating; Force istribution plate; Duct pipe, can be cut to length; Fastening material Article no. PU1 PU Pluvia grating, loa bearing 1500kg for promenae For Pluvia roof outlets with max. rainage capacity 12 l/s Overflow element can be cut to length Overflow height Height of aing Lip seal EPDM Article no. PU1 PU4 Coents Incluing plastic mounting clips for plastic function isk Incluing metal mounting clips for metal function isk Set of Pluvia mounting clips for overflow aaptor (spare) For car park use, 1500kg For promenae outlet Article no. PU mounting clips for plastic outlets; 2 mounting clips for metal outlets Article no. PU Pluvia grating, light loa bearing, 150 kg for promenae 32 Pluvia contact foil For peestrian use, 150kg For promenae outlet Fastening material Article no. PU For connecting metallic materials For installation in gutters with a minimum of 35 cm with Conensation insulation ring Article no. Sealing of connection PU1 PU Chrome-nickel steel Copper Peraluman 1 Pluvia Prouct an Installation Guie

11 Prouct Guie Series 7 Pluvia spares Pluvia contact foil Series 7 Pluvia contact clamping flange For connecting with roof foils Article no. Sealing of connection PU1 PU PVC - Sarnafil G EPDM - Resistit Perfekt E PVC - Sikaplan 15 G 1 66 For connecting metallic materials For making a mechanical connection For installing in gutters minimum 38 cm wie Article no. PU Pluvia contact foil bitumen Pluvia installation sheet For connecting with bitumen roof foils Protection box cover, heat-resistant Article no. PU Pluvia contact foil stainless steel For fastening the base unit on trapezoial roofs For use with all Pluvia roof outlets 12 l Hot-ip galvanise Prouct material Article no. PU1 PU Steel 52 Pluvia storm set For connecting with bitumen roof foils Protection box cover, heat-resistant; Conensation insulation ring Article no. Sealing of connection PU Chrome-nickel steel 1 For stormproof attachment of the Pluvia 12 litre outlet grating Can also be use for Pluvia roof outlets with emergency overflow set 2 clips; 2 spacers; 2 washers; 2 washer sleeves; 2 cap nuts Article no Pluvia spares 10 Pluvia Prouct an Installation Guie 2011

12 Prouct Guie Pluvia spares Series 7 Series 7 Pluvia spares Pluvia perforate upstan for promenae outlet Pluvia Base Element For use with Pluvia roof outlets 12 l with HDPE base units For siphonic roof rainage system For connecting vapour barriers up to 3 thick For combination with Pluvia vapour barrier connection, fastening isk an contact foil Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Drainage capacity max. Connecting material Base unit; Insulation against conensation; Protective cap Exclue: Fastening isk; Fastening material Article no. Ø PU1 PU l/s PE-HD Article no. PU1 PU Pluvia 2 tier outlet, lower element for sealing penetration through vapour barrier 0-13 For use with Pluvia roof outlets 12 l with HDPE base units For siphonic roof rainage system For connecting vapour barriers up to 3 thick Outlet pipe irectly reucible / extenable Outlet pipe can be cut own 80 C heat resistant Clamping ring with pull-out protection up to 120 kg Pluvia base plate for uct, loa bearing for promenae Connecting material Drainage capacity max. PE-HD 12 l/s Article no. PU Base unit; Fastening isk; Insulation against conensation; Fastening material; Protective cap; Lubricants Article no. Ø PU1 PU Pluvia frame for loa bearing gratings for promenae 32 5 Clamping flange for vapour barrier membrane For connecting vapour barriers up to 3 thick Shoul not be use for connecting insulating roof foils Article no. PU Article no. PU1 PU3 PU Pluvia Prouct an Installation Guie

13 Prouct Guie Series 7 Pluvia spares Fastening isc for vapour barrier Pluvia outlet isk for roof outlet O-rings EPDM; Lip seal EPDM; Clamping ring; Locking screw Article no. PU Article no. Ø Gravel ring 28 5 Lip seal an grab ring for fastening isc for vapour barrier For vapour barrier outlet Article no. PU For holing back roof gravel with a grain size of 8-16 For combination with Pluvia outlet grating Prouct material Article no. PU1 PU Stainless steel Pluvia outlet grating for roof outlet Pluvia fastening isc for roof outlet O-rings EPDM Article no. Ø PU For Pluvia roof outlets with max. rainage capacity 12 l/s Article no. PU1 PU Pluvia protection cover, fire resistant Set of seals for outlet fastening iscs Roun cor ring EPDM ø 62 x 6 ; Roun cor ring EPDM ø 134 x 6 Article no. PU1 PU For use with a blowlamp Heat-resistant Article no. Ø PU Pluvia Prouct an Installation Guie 2011

14 Prouct Guie Pluvia outlets Series 7+ Pluvia Series outlets 7+ Series 7+ Pluvia outlets Series 7+ flange Pluvia outlet stainless steel Pluvia roof outlet 25 l universal for plastic roof membranes For collecting an raining of rainwater on roofs For siphonic roof rainage system For connection of plastic roof membranes May not be use for flange mounting roof foils with fleece coating (e. g. Rhepanol fk) Loa of the outlet grating < 150 kg 80 C heat resistant Base unit with integrate outlet isc Outlet grating with function isc Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Maintenance free clamping flange connection Drainage capacity min. Drainage capacity Height of aing Outlet grating with operating part; Outlet connection flange with seal an nuts; Base unit with integrate outlet isk mae of metal; Protection housing Article no. Ø PU l/s 25 l/s 55 For collecting an raining of rainwater on roofs For siphonic roof rainage system For connecting with bitumen roof foils Loa of the outlet grating < 150 kg 80 C heat resistant Base unit with integrate outlet isc Outlet grating with function isc Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Drainage capacity min. Drainage capacity Height of aing Outlet grating with operating part; Outlet connection flange with seal an nuts; Base unit with integrate outlet isk mae of metal; Protection housing Article no. Ø PU1 PU Series 7+ Pluvia outlet stainless steel without flange For collecting an raining of rainwater on roofs For siphonic roof rainage system For installation in gutters with a minimum of 35 cm with For connecting metallic materials l/s 25 l/s 55 Loa of the outlet grating < 150 kg 80 C heat resistant Base unit with integrate outlet isc Outlet grating with function isc Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Drainage capacity min. Drainage capacity Height of aing 8 l/s 25 l/s 55 Outlet grating with operating part; Base unit with integrate outlet isk mae of metal Exclue: Protection cover Article no. Ø PU1 PU Pluvia Prouct an Installation Guie

15 Prouct Guie Pluvia rail an fixing system Pluvia grating for outlet 25 l/s Pluvia outlets Geberit Pluvia vapour barrier connection vertical 25 l For all Pluvia roof outlets with 25, 45, 60 or 100 l/s flow capacity Integrate function isc Lock nut Article no. PU Emergency overflow set for Pluvia roof outlets 25 l For use with Pluvia roof outlets with max. rainage capacity 25 l/s 5 5 For collecting an raining of rainwater on roofs For siphonic roof rainage system For combination with Geberit Pluvia roof outlets 25 l For use with insulate roofs with vapour barrier For connecting plastic or bitumen vapour barriers Fix installe HDPE outlet pipe ø 90 Outlet pipe irectly reucible / extenable Contact sheet galvanize Drainage capacity min. Drainage capacity Height of aing Protective cap Article no. Ø PU ø 9 8 l/s 25 l/s 55 Overflow height Height of aing Pluvia rail an fixing system Roun cor ring EPDM; Fastening material Article no. PU1 PU Pluvia Prouct an Installation Guie 2011

16 PluviaFix Brackets Prouct Guie Pluvia rail an fixing system PluviaFix Brackets PluviaFix Brackets PluviaFix pipe bracket for guie an anchor point L For attaching pipes to ceilings an vertically to walls For fastening with tension wege For fastening to the PluviaFix support rail square profile For slie fastening of pipes For anchor-point fastening of pipes in combination with electrowel couplings or tapes For rigi fixing of 40 HDPE pipework Galvanise Prouct material Steel Exclue: Tension wege Article no. Ø L cm Please note: For conventional brackets please see the HDPE Prouct Guie. PU1 PU2 Pluvia Prouct an Installation Guie

17 Prouct Guie Pluvia rail an fixing system PluviaFix Brackets PluviaFix pipe bracket for guie an anchor point L1/L2 For attaching pipes to ceilings an vertically to walls For fastening with tension wege For fastening to the PluviaFix support rail square profile For slie fastening of pipes For anchor-point fastening of pipes in combination with electrowel couplings or tapes For rigi fixing of HDPE pipework 50 to 100 Galvanise 1 2 Prouct material Steel Exclue: Tension wege Article no. 1Ø 2Ø L1 cm L2 cm PU1 PU2 PU ,9 11, ,2 11, ,8 12, ,4 12, ,3 13, ,4 14, ,1 15, , PluviaFix pipe bracket for guie an anchor point L1/L2 1 2 For fastening with tension wege For fastening to the PluviaFix support rail square profile For slie fastening of pipes For attaching pipes to ceilings an vertically to walls For anchor-point fastening of pipes in combination with electroweling tapes Galvanise With securing clip Prouct material Steel Securing clip Exclue: Tension wege Article no. Ø 1Ø 2Ø L1 L2 Colour PU1 PU2 PU4 cm cm ,4 Galvanise / blue passivate Pluvia Prouct an Installation Guie 2011

18 PluviaFix square profile track system Prouct Guie Pluvia rail an fixing system PluviaFix square profile track system PluviaFix square profile rail system PluviaFix steel square section rail L(m) 3 PluviaFix suspension element for steel square section rail M M For attaching pipes to ceilings an vertically to walls For fastening of pipe brackets with clamp fastening Galvanise Square profile Prouct material Article no. L (m) m Colour Steel PU2 m PU4 m Galvanise / blue passivate For attaching pipes to ceilings an vertically to walls For fastening steel square section rail Galvanise Female threa With long threa coupling wele on Prouct material Exclue: Tension wege Steel Article no. Colour PU1 PU2 PU Galvanise / blue passivate PluviaFix connection element for steel square section rail PluviaFix tension wege for square profile M10 2 M L 20 3 For attaching pipes to ceilings an vertically to walls For connecting steel square section rails Galvanise With long threa coupling wele on Prouct material Exclue: Tension weges Steel Article no. Colour PU1 PU2 PU Galvanise / blue passivate For attaching pipes to ceilings an vertically to walls For fastening pipe brackets, suspension an connection elements on support rail For fastening to the PluviaFix support rail square profile Galvanise Prouct material Steel Article no. L Colour PU1 PU2 PU4 cm Galvanise / blue passivate Pluvia Prouct an Installation Guie

19 Prouct Guie Pluvia rail an fixing system PluviaFix pipe brackets with threae fastening PluviaFix pipe brackets with threae fastening PluviaFix pipe brackets with threae fastening PluviaFix pipe bracket for pipe use with PluviaFix C profile support rail PluviaFix pipe anchor bracket set with sleeve M16 with fixe-point weling strip for C profile support rail, set with 2 pieces 250 M M l l L L B B For attaching pipes to ceilings an vertically to walls For fastening to the PluviaFix support rail C-profile For slie fastening of pipes For fastening with threae ros For attaching pipes to ceilings an vertically to walls For fastening to the PluviaFix support rail C-profile For fixe-point fastening of pipes For fastening with threae ros Galvanise Female threa Galvanise Female threa Prouct material Steel Prouct material Steel Fastening material Article no. Ø M B cm L cm l cm PU1 PU2 PU , Pipe bracket; Fixe-point weling strip; Fastening material Article no. Ø M B L l PU1 PU2 PU4 cm cm cm , Pluvia Prouct an Installation Guie 2011

20 PluviaFix C profile track system for pipe iameters Prouct Guie Pluvia rail an fixing system PluviaFix pipe anchor bracket set with sleeve M16 with fixe-point weling strip for C profile support rail, set with 2 pieces 315 PluviaFix suspension element for C profile M l L B For attaching pipes to ceilings an vertically to walls For fastening C profile support rails with threae ros M10 Galvanise Fastening material For attaching pipes to ceilings an vertically to walls For fastening to the PluviaFix support rail C-profile For fixe-point fastening of pipes For fastening with threae ros Galvanise Female threa Prouct material Steel Article no. PU1 PU PluviaFix connection element for C profile B H L 2 fixe-point weling strips; 2 pipe brackets; Fastening material Article no. Ø M B L l PU1 PU4 cm cm cm PluviaFix C profile track system for pipe iameters PluviaFix C profile track system for pipe iameters PluviaFix C profile support rail For attaching pipes to ceilings an vertically to walls For connecting C profile support rails Galvanise Fastening material Article no. B H L PU1 PU2 cm cm cm , B H L(m) For attaching pipes to ceilings an vertically to walls For fastening pipe brackets with threa fastening M16 Galvanise C profile Article no. B H L (m) PU2 PU4 cm cm m m m Pluvia Prouct an Installation Guie

21 Prouct Guie Pluvia rail an fixing system Mounting plates Mounting plates Mounting plates Mounting plate, light with sleeve M8 / M10 M h H B a L For attaching pipe brackets to the builing structure For attaching pipes to ceilings an vertically to walls For slie fastening For attaching support rails to the builing structure Galvanise Female threa 2 fastening points Prouct material Steel Article no. M a B H h L Colour PU1 PU3 cm cm cm cm cm / 10 5,5 3 1,9 0,3 8 Galvanise / blue passivate 1 50 Threae ro M10 For attaching pipe brackets to the mounting plate For fastening of support rails on mounting plate Male threa With protective shell PVC sleeve Article no. M L cm PU1 PU2 PU Pluvia Prouct an Installation Guie 2011

22 Mounting plates Prouct Guie Pluvia rail an fixing system Support shells galvanise insie with black painte finish L(m) s Coate Galvanise Article no. Ø L (m) m PU2 m PU3 m PU4 m Pluvia Prouct an Installation Guie

23 Prouct Guie Pluvia rail an fixing system Electrofusion tape for anchor bracket Electrofusion tape for anchor bracket Electrofusion tape for anchor bracket Electrofusion tape for anchor bracket D 1 h H For fixe-point fastening of pipes in conjunction with pipe brackets 1-section Can be wele with Geberit electrofusion machine Prouct material PE Article no. Ø 1Ø D cm H cm h cm Colour PU1 PU2 PU3 PU ,6 6 3 Black ,2 6 3 Black ,9 6 3 Black ,1 6 3 Black ,6 6 3 Black ,6 6 3 Black ,1 6 3 Black ,6 6 3 Black ,6 6 3 Black ,6 6 3 Black Electrofusion tape for anchor bracket D h 1 H For fixe-point fastening of pipes in conjunction with pipe brackets 2-section Can be wele with Geberit electrofusion machine Prouct material PE Article no. Ø 1Ø D H h Colour PU1 PU2 PU4 cm cm cm ,1 6 3 Black Pluvia Prouct an Installation Guie 2011

24 PluviaFix support sets Prouct Guie Pluvia rail an fixing system PluviaFix support sets PluviaFix support sets PluviaFix support set ø PluviaFix support set ø 200 M M L L M M M M For aitional support of the PluviaFix fastening system uner unfavourable conitions For horizontal pipe fastening For installation uring pipe installation For subsequent installation For ø 75 pipes that are suspene more than 100 cm For ø pipes that are suspene more than 60 cm For fastening to the PluviaFix support rail square profile Galvanise Articulate connection can be rotate through 180 For aitional support of the PluviaFix fastening system uner unfavourable conitions For horizontal pipe fastening For installation uring pipe installation For subsequent installation For pipes suspene more than 60 cm For fastening to the PluviaFix support rail square profile Galvanise Articulate connection can be rotate through 180 With securing clip Prouct material Steel Prouct material Steel Article no. Ø M L PU1 PU2 PU4 cm , , , , Securing clip Article no. Ø M L PU1 PU2 cm Pluvia Prouct an Installation Guie

25 Prouct Guie Pluvia rail an fixing system PluviaFlex PluviaFix support set ø PluviaFlex PluviaFlex M l PluviaFlex Pipe M M L L(m) D For aitional support of the PluviaFix fastening system uner unfavourable conitions For horizontal pipe fastening For installation uring pipe installation For subsequent installation For pipes suspene more than 60 cm For fastening to the PluviaFix support rail C-profile Galvanise Articulate connection can be rotate through 180 Prouct material Fastening material Steel Article no. Ø M L l PU1 cm cm ,8 10, ,5 1 For flexible routing of negative pressure rainwater rains For use with Pluvia roof outlets 6 l an 12 l For pipe imensions ø For pipes with a thermal loa between -10 an +50 C For use within builings For connecting rainwater outlet elements For flexible Pluvia connection pipes in imensions ø For combination with tension resistant connection of pipes Not suitable for pipework in support shells Is not allowe to be use for Pluvia roof outlets 25 l l Can be connecte on both sies with electrowel sleeve coupling Cannot be shortene Article no. Ø D L (m) PU1 PU2 PU4 cm m ,2 1, ,4 1, ,1 1, , ,2 1, PluviaFlex fastening belt For flexible routing of negative pressure rainwater rains For use with Pluvia roof outlets 6 l an 12 l For pipe imensions ø For pipes with a thermal loa between -10 an +50 C For use within builings For fastening the PluviaConnect connection pipe with horizontal installation close to the ceiling Not suitable for pipework in support shells Is not allowe to be use for Pluvia roof outlets 25 l l With pushbutton fastening Exclue: Fastening material Article no. PU1 PU Pluvia Prouct an Installation Guie 2011

26 PluviaFlex Prouct Guie Pluvia rail an fixing system PluviaFlex fixation set For flexible routing of negative pressure rainwater rains For use with Pluvia roof outlets 6 l an 12 l For pipe imensions ø For pipes with a thermal loa between -10 an +50 C For use within builings For attaching the outlet pipe up to ø 75 Not suitable for pipework in support shells Is not allowe to be use for Pluvia roof outlets 25 l l Galvanise Prouct material Steel Fastening material Article no. PU1 PU Pluvia Prouct an Installation Guie

27 Prouct Guie Pluvia rail an fixing system PluviaFlex 26 Pluvia Prouct an Installation Guie 2011

28 Installation Guie Siphonic System Elements Guie Installation Guie All Geberit Pluvia rainwater systems in the UK an Irelan are installe by fully traine Approve Installers, who will prepare the final esign for the project an will check at all the construction stages shoul there be any variations to the esign that the system will operate siphonically using the Geberit Pro- Planner software. The Pluvia roof rainage system consists of: Pluvia roof outlets Geberit HDPE rainage system PluviaFix fastening system ProPlanner esign software 1. Siphonic System Elements 1.1. Pluvia Roof Outlets 1.3. PluviaFix Fastening System The Geberit Pluvia fastening system was evelope for the installation of horizontal pipework. Avantages of the rail system: Quick installation Fewer ceiling fastening points Controls thermal movement No expansion because of rigi installation No expansion sockets in the horizontal pipes Simple prefabrication is possible One fastening for anchor an sliing brackets The expansion an contraction of the pipework is prevente by the rail system as the properties of HDPE allows rigi fixing. Pluvia Rail Threae Ro M10 Tension Wege Geberit Pluvia outlets are evelope for all types of roof structures. Due to the ifferent ischarge rates of the outlets (6 l/s, 12 l/s or 25 l/s) an economical layout of the roof rainage system can be reache. The wie range of contact sheets an accessories allows connection to most roof finishes Geberit HDPE Drainage System Pluvia Bracket Connector to Rail Fig. 1: Geberit PluviaFix Rail System Rail Clamp Geberit ProPlanner Design Software The highly avance software package easily allows the calculation of the most complex roof projects. The Geberit HDPE range of pipes an fittings complements the Pluvia outlet to provie a total rainage solution. Geberit HDPE is available in iameters , an can be jointe in a variety of ifferent methos incluing electrofusion, butt weling an mechanical coupling. The outstaning material characteristics of Geberit HDPE allow specifiers an contractors to esign an pre-fabricate pipe runs away from the site of the installation. Pipe runs can be create in a safe, clean environment ensuring secure an accurate fabrication as well as consierable material an labour savings Manufacture to BS EN 1519: All pipe iameter 40 to 315 are available to at least PN 4 specification an are suitable to -800 mbar negative pressure Pipe in 200 to 315 iameters are also available to PN 3.2 specification an are suitable to -450 mbar negative pressure Fig. 2: Geberit ProPlanner Pluvia Prouct an Installation Guie

29 Installation Guie Methoology for Designing the Pluvia System It offers istinct avantages: Convenient an very easy to operate Consierable time savings BBA approve Meets the BS8490 Coe of practice for siphonic systems Provies - Isometric rawings - Hyraulic calculations - Material list incl. fixing components - Cost calculation with reay to mail tener ocuments 2. Methoology for Designing the Pluvia System 2.1. Step 1 Determine the roof(s) rainage patterns 2.2. Step 2 Calculate the areas of roof(s) raining to each outlet 2.3. Step 3 Determine the rainfall intensity rate Metho A Geberit recoen using 108 /hr (0.03 l/s per sqm). In the UK an Irelan this figure provies a frequent return rate for a 2 minute storm which ensures the systems self cleansing routine is activate Metho B Use the metho an ata provie in BS EN part 3. We o however avise against using the very high rainfall intensity rates that can be generate if long life spans for the builing an high safety factors (categories) are use in the calculations. Example: Project locate in Lonon requiring 25 year life span protection, Category 3 Safety Factor. This will result in a rainfall intensity rate of 236 /hr. In reality this will mean that once every years for 2 minutes there may be a storm with a rainfall intensity of 236 /hr. Using this high rainfall rate will result in the systems pipework being massively oversize, which will result in the system not operating siphonically frequently, requiring a high level maintenance prograe to check for silt buil up in the pipes. Geberit recoen using the rainfall rate mentione in Metho A an allowing any potential higher rate rainfall to temporarily accumulate on the roof (for valley gutters this may require some over sizing of the gutter to provie aitional storage capacity). Example: If the 236 /hr protection is require, esign a primary system to cope with 108 /hr. Given: Require rainfall intensity rate: 236 /hr Recoen rainfall intensity rate: 108 /hr Require: Buil up from the excess over 2 minutes (1/30 hr) [] Solution: = hr hr hr hr = 4.3 hr Buil up = 4.3 If the above mentione temporary storage metho is not acceptable then one of the three options below may be use: Option 1: Weir overflows in the parapet walls Option 2: A seconary siphonic overflow system Option 3: A separate internal overflow system (gravity) In all roof esigns an emergency / warning overflow must be provie to inicate a blockage within the system. 28 Pluvia Prouct an Installation Guie 2011

30 Installation Guie Choosing the Correct Pluvia Outlet 3. Choosing the Correct Pluvia Outlet 3.1. Outlet Series Series 5 Outlets (6 l/s capacity) Series 7+ Outlet (25 l/s capacity) Fig. 3: Series 5 Outlet Flow Rate On a flat roof or in a wie gutter (1 m min. with) l/s In a narrow gutter (min. with 300 ) * l/s * Narrow gutter must be at least 100 wier than outlet iameter Series 7 Outlets (12 l/s capacity) Fig. 4: Series 7 Outlet Fig. 6: Series 7+ Outlet Flow Rate On a flat roof or in a wie gutter (1 m min. with) l/s In a narrow gutter (min. with 420 ) * l/s * Narrow gutter must be at least 100 wier than outlet iameter 3.2. Overflow Provision All roofs shoul have some provision of emergency overflow to protect the builing from unplanne buil-up of water on the roof or in the gutter. This can take form of: Weir overflows in the parapet wall or gutter ens Stan pipes through the roof or gutter ischarging via pipes to the groun Seconary gravity or siphonic system which incorporates an internal aaptor in the outlet which prevents water from entering the system until it reaches a epth of at least 55. This system can also ischarge at groun level (not connecte to the rainage system) ue to its infrequency of use plus to give an inication that the roof is flooing for some reason Geberit overflow aaptors can be installe in the Series 7 an Series 7+ type outlets. Series 5 outlets will nee to be raise on a plinth to restrict water flow until the esire height has been reache. Fig. 5: Series 7 Promenae Outlet On a flat roof or in a wie gutter (1 m min. with) In a narrow gutter (min. with 400 ) * With a horizontal spigot less than 100 from roof eck to centre of pipe * Narrow gutter must be at least 100 wier than outlet iameter Flow Rate l/s l/s l/s Fig. 7: Geberit overflow aapter for Series 7 Fig. 8: Geberit overflow aapter for Series 7+ Pluvia Prouct an Installation Guie

31 Installation Guie Connecting the Outlet to the Roof 4. Connecting the Outlet to the Roof Fig. 9: PVC Roof Finish Fig. 12: Steel Profile Roof Deck with Vapour Barrier Clamping Unit Fig. 10: Asphalt Roof Finish Fig. 13: Horizontal Outlet in a Gutter Min. 400 Fig. 14: Steel Gutter Outlet Fig. 11: Clamping Outlet in a Concrete Roof 30 Pluvia Prouct an Installation Guie 2011

32 Installation Guie Connecting the Outlet to the Roof Fig. 18: Timber Roof Construction Fig. 15: Concrete Roof (no Vapour Barrier) Fig. 19: Overflow Aapter Fig. 16: Concrete Roof (with a Vapour Barrier) Fig. 20: 25 Litre Outlet Fig. 17: Promenae Outlet Pluvia Prouct an Installation Guie

33 Installation Guie System Installation Requirements 4.1. Connecting Various Roofing Materials to Outlets Geberit outlets are available in various forms: Fig. 21: All metal with a 500 square flange suitable for boning to liqui bitumen 5. System Installation Requirements 5.1. The Internal pipe work that makes up the siphonic system must follow the following rules All pipe work must be Geberit HDPE All horizontal pipe work must be lai level (no fall unless agree with Geberit) All horizontal pipe work joints must be either butt wele or electrofusion wele (no mechanical or seal ring joints) Vertical pipes may be either wele or seal ring jointe Horizontal pipes must be restraine to prevent thermal movement preferably with the Geberit Rail System Fig. 22: All metal with a 20 wie lip for weling to gutter Fig. 23: Clamping ring version to accept waterproof sheet hel mechanically All vertical seal ring fittings if use must be anchore with a suitably strong bracket (12 stu) All pipe iameters must follow the esign create by the Geberit ProPlanner software an to checke at all changes in pipe route by the Geberit Approve Installer before final sign-off All changes in irection or branch connection must be mae using 45 egree fittings. The only exception to this is ieiately below the outlets where a 90 egree ben may be use Fig. 24: With 'clamp in' foils of numerous material to suit a large number of roofing membrane types Only one reuction in pipe iameter is permitte at the top of the main vertical rop if the software permits it Fig. 25: Series 5 an Series 7+ metal outlets are also suitable for hot applie mastic asphalt resse into the bowl 32 Pluvia Prouct an Installation Guie 2011

34 Installation Guie System Installation Requirements 5.2. Horizontal Pipe Work Bracketing Detail Fig. 26: Geberit Rail System Metho Pipe bracket spacing With shells Without shells Pipe iameter [] RA [m] RA [m] Fig. 27: Conventional Bracketing Metho 33 Pluvia Prouct an Installation Guie 2011

35 Installation Guie System Installation Requirements 5.3. Methos of Creating Fixe an Sliing Supports Horizontal Expansion joint For spacing between guie brackets see table Max. 5 m Fig. 28: Using Geberit PluviaFix Rail System Expansion joint Horizontal or Vertical Fig. 30: Using Expansion Joints Anchor Point with Electrowel Tape Fittings must be strong enough to resist forces of thermal expansion (See HDPE Installation Guie for ata) Max. 5 m Sliing brackets For spacing between guie brackets see table Fig. 29: Using Conventional Fixing Vertical Instruction for expansion joint metho The following conitions are important to ensure perfect an easy assembly of the sleeve: Chamfering the inserte pipe en to approximate 15 Check the scale on the outer surface of the expansion socket for insertion epth Mark the correct insertion epth on the pipe Lubricate the pipe en well with soft soap, silicone or vaseline. N.B. Do not use oil or grease which can amage the rubber seal Anchor Point with Electrowel Tape Fig. 31: Rigi Fixing Fittings must be strong enough to resist forces of thermal expansion (See HDPE Installation Guie for ata) Table 1: Diameter [] Vert. [m] Table A Pluvia Prouct an Installation Guie 2011

36 Installation Guie PluviaFlex System an Alternative Approach to Installing Pipe Work 5.4. Siphon Break Methos At the point where the siphonic system connects to the gravity rain the siphonic action must be stoppe. This is achieve by oubling the cross sectional area of the pipe bore (point A) using one of the methos show below. The gravity rain (B) must be size to accept the flow without surcharging. 6. PluviaFlex System an Alternative Approach to Installing Pipe Work The PluviaFlex system has been evelope to offer an alternative metho of installing the horizontal pipe work without using fixe anchor points or rigily fixing the system to prevent thermal movement. The flexible hose will allow the pipe work to expan an contract within limits. Fig. 32: Metho 1: Below Floor Slab Fig. 37: PluviaFlex System General information on the PluviaFlex system The installation temperature must be between -10 C an +50 ºC. (The change in length of the PE materials has been taken into account in the esign of the PluviaFlex components with a corresponing Δt) Fig. 33: Metho 2: Above Floor Slab Fig. 34: Metho 3: After Seale Access in Manhole Support shells an insulation against conensation may not be use with the PluviaFlex system. (These woul negatively affect the necessary sliing effect) The length of straight pipelines may only be max. 50 m Each ownpipe of the PluviaFlex system must be equippe with a fixe point at the irection of change or after the iverting zone area No fixe points may be installe in the entire system (except for ownpipe) Fig. 35: Metho 4: Minimum Distance before Manhole Fig. 36: Metho 5: Open Pluvia Systems are not permitte Pluvia Prouct an Installation Guie

37 Installation Guie Technical Data 7. Technical Data 7.1. Outlet Types Series Min. flow capacity Max. flow capacity Discharge capacity (outlet in gutter) Outlet spigot iameter [l/s] [l/s] [l/s] [] Series 5 Outlet (Small) Stanar Series 7 Outlet High Capacity Series Design Parameters Min. pipe iameter 40 Max. pipe iameter 315 Min. flow velocity 0.7 m/s Min. water to air ratio 60 % Max. negative pressure (PN4)* mbar Max. negative pressure (PN3.2)* mbar Max. negative pressure (PN4)* mbar Min. 2 outlets to be installe on a system Emergency warning overflows must be provie on all roofs Pluvia outlets shoul be space no further than 20 m apart Pluvia outlets shoul be space no further than 10 m from en of gutter All horizontal pipes must be lai level (no graient) 7.3. PluviaFix Rail with Full Pipe Weights Pipe iameter Pipe weight full Rail weight an bracketry Total weight [] [kg/m] [kg/m] [kg/m] Pluvia Prouct an Installation Guie 2011

38 Installation Guie Testing of System 7.4. Pluvia Rail Fastening System Dimensions Pipe iameter Bracket [] [] A B C D E F Maintenance Maintenance of System Geberit recoen that a maintenance prograe is always implemente on completion of the project. The intervals between inspection will epen on the location of the builing. The maintenance prograe shoul inclue: 1 2 Clean all outlets of any ebris or silt Remove li M10 rop ro PluviaFix bracket PluviaFix Rail Tension wege 3 Remove function isc HDPE pipe B C F b A Fig. 38: Guie brackets on rail E D 4 Rinse function isc with water 40 PluviaFix rail M10 rop ro B C HDPE pipe F A 5 Wipe outlet with cloth D E PluviaFix support bracket Fig. 39: Guie brackets on rail Testing of System On completion of a Geberit Pluvia system the integrity of all joints must be teste using an air test as escribe in BS EN 12056, which in general requires a 38 air test for 3 minutes If the installation has been esigne using the Geberit software it is not normally necessary to performance test the installation. Thir party approval by the BBA inclue verification that the software is a true reflection of the actual flow performance. 6 7 Check that no pipes connecting to outlets are blocke with silt etc., if blockages are foun they can be remove by using a water jet through the outlet after removing the li an function isc as shown above Ensure all outlets have gratings an tops in place. Orer spares from Geberit if necessary Pluvia Prouct an Installation Guie

39 Installation Guie Maintenance 38 Pluvia Prouct an Installation Guie 2011

40 Numerical inex Article no. Page Article no. Page Pluvia Prouct an Installation Guie

41 Geberit Sales Lt Geberit House Acaemy Drive Warwick Warwickshire CV34 6QZ T F Eire +44 (0) Literature Subject to change without notice. The information in this ocument contains general escriptions of the technical options available, which o not always have to be present in the iniviual cases. The require features shoul therefore be specifie in each iniviual case at the time of closing the contract. Geberit, August 2011.

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73.

Description. Outlets Page 62. Contact foil Page 65. Accessories Page 65. Outlets Page 68. Accessories Page 69. Brackets Page 73. Pluvia Syphonic roof rainage system Description Outlets Page 62 Pluvia outlets 12 l Contact foil Page 65 Accessories Page 65 Pluvia outlets 25 l Outlets Page 68 Accessories Page 69 Pluvia outlets 45/60/100

More information

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l

Geberit Pluvia. Syphonic roof drainage system. Overview Page 42. Geberit Pluvia outlets 6 l. Geberit Pluvia outlets 14 l Geberit Pluvia Syphonic roof rainage system Description Overview Page 42 Geberit Pluvia outlets 6 l Outlets Page 43 Contact foil Page 43 Outlets Page 44 Geberit Pluvia outlets 14 l eating element Page

More information

3. Geberit Pluvia Roof Drainage Systems

3. Geberit Pluvia Roof Drainage Systems 3. Geberit Pluvia Roof Drainage Systems Assortment overview: Pluvia Outlets...52 3.1 Roof outlets... 53 3.1.1 Roof outlets up to 25 l/s...53 3.1.2 Roof outlets up to 100 l/s...55 3.2 Roof outlets for gutters...

More information

Syphonic Roof Drainage

Syphonic Roof Drainage Page 1 T E C H N O L O G Y 2:39 pm Syphonic Roof Drainage P L U M B I N G 23/5/03 A D V A N C E D Prod & Price Gd.for PDF Product Guide SYPHONICS Advanced Roof Drainage Technology Geberit Syphonics Geberit

More information

Syphonic Roof Drainage

Syphonic Roof Drainage Syphonic Roof Drainage A D V A N C E D P L U M B I N G T E C H N O L O G Y Design Guide SYPHONICS Advanced Roof Drainage Technology Design, Manufacture and Installation TSB Call Centre, Cardiff. Millenium

More information

Geberit Pluvia. Product Guide and Price List. Valid from 1 March 2016 (Prices exclusive of VAT)

Geberit Pluvia. Product Guide and Price List. Valid from 1 March 2016 (Prices exclusive of VAT) Geberit Pluvia Prouct Guie an Price ist Vali from 1 arch 2016 (Prices exclusive of VAT) 3 Geberit Pluvia Roof Drainage Systems 1. Geberit Pluvia Roof Drainage Systems 1.1 Preliminary remarks...6 1.2

More information

Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall

Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall Geberit Pluvia siphonic roof drainage system. Stands up to every kind of rainfall Geberit Pluvia projects. Proven application. Westfield Shopping Centre, Stratford UK Guangdong Science Centre, China Hotel

More information

Geberit Mapress Catalogue 2008 / 2009. Valid from 1 April 2008

Geberit Mapress Catalogue 2008 / 2009. Valid from 1 April 2008 Geberit Mapress Catalogue 2008 / 2009 Vali from 1 April 2008 Mapress Stainless Steel Page 3 Mapress CrNi Steel Page 23 Mapress Stainless Steel silicone-free Page 25 Mapress Stainless Steel Gas Page 39

More information

Marine Catalogue 2013

Marine Catalogue 2013 Marine Catalogue 2013 escription Moel Packaging Hep 2 O Barrier Pipe Re Conuit 15 L = 50 mtr WBCL010305A orer pipe by unit (coil) not by meter 22 L = 50 mtr WBCL010306A straight connector 15 10 pieces

More information

11 CHAPTER 11: FOOTINGS

11 CHAPTER 11: FOOTINGS CHAPTER ELEVEN FOOTINGS 1 11 CHAPTER 11: FOOTINGS 11.1 Introuction Footings are structural elements that transmit column or wall loas to the unerlying soil below the structure. Footings are esigne to transmit

More information

Products no longer available

Products no longer available Technical ata sheet R6..R haracterize control valves, 2-way, with flange PN 6 for open an close col an warm water systems for moulating control on the water sie of air-hanling an heating systems air bubble-tight

More information

Geberit Pluvia Syphonic roof drainage system. Stands up to every kind of rainfall

Geberit Pluvia Syphonic roof drainage system. Stands up to every kind of rainfall Geberit Pluvia Syphonic roof drainage system Stands up to every kind of rainfall What is Pluvia? Geberit Pluvia is a roof drainage system based on an intelligent negative pressure suction system. In contrast

More information

0845 0098 980 www.nicholsonsts.com

0845 0098 980 www.nicholsonsts.com 0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution

More information

Puddle Flange. FRANK Puddle Flange

Puddle Flange. FRANK Puddle Flange Puddle Flange FRANK Puddle Flange The problem Problems keep on occurring when connecting pipes during construction work. Pipes laid in the ground must be introduced into concrete walls or shafts. In many

More information

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology Modern Efficient Performance Cost Effective Flat Roofing Systems Introduction A complete range of Memtec Roofing and Waterproofing Single

More information

Saferand easierinstallation

Saferand easierinstallation EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little

More information

ROOF DRAINS TABLE OF CONTENTS

ROOF DRAINS TABLE OF CONTENTS Pictorial Index Product Recommendations Roof Drain Selection Factors Sizing Placement Material & Characteristics Pipe Connection Commonly Specified Options Typical Installations TABLE OF CONTENTS ROOF

More information

DIFFRACTION AND INTERFERENCE

DIFFRACTION AND INTERFERENCE DIFFRACTION AND INTERFERENCE In this experiment you will emonstrate the wave nature of light by investigating how it bens aroun eges an how it interferes constructively an estructively. You will observe

More information

BLS 100 Orifice Plate DIN 19206

BLS 100 Orifice Plate DIN 19206 E91 2006 1Orifice Plate, Orifice Flange, Meterrun, Restriction Orifice Application Flow rate measurement of aggressive an nonaggressive meia particularly for large pipelines. Construction Orifice plate

More information

Pipe Clamps and Accessories

Pipe Clamps and Accessories Products 4.0 Products 4.1 Connection options to pipe clamps with Triple-Thread Connector NT 3G (M16, M10, M8) 4.2 Connection options to pipe clamps with Triple-Thread Connector NT 3G (3/8", M12, M10) 4.3

More information

Rooflight INSTALLATION INSTRUCTIONS

Rooflight INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Rooflight These instructions should be used for: Installing Permanent Trickle Ventilation: Constructing & Waterproofing a Timber Upstand Curb: Installing & Waterproofing Proprietary

More information

A WATERTIGHT SYSTEM. In a nutshell: a system that fully meets present-day requirements.

A WATERTIGHT SYSTEM. In a nutshell: a system that fully meets present-day requirements. A WATERTIGHT SYSTEM In response to the need for a quick, efficient and cost effective way to drain rainwater from larger roofs DYKA has developed the VACURAIN roof rainwater drainage system. A high-quality

More information

Rack & Pinion Lubrication Systems

Rack & Pinion Lubrication Systems Page Lubricator 125 cm 3 ZE-2 Lubricator 475 cm 3 ZE-3 Selection of the Lubrication for Rack Drives ZE-4 Lubrication System ZE-5 6 Felt Gear ZE-7 8 Lubrication Equipment, Accessories ZE 9 Lubricating Systems

More information

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD channel drainage system Technical Data ACO MultiDrain MD Introduction to the

More information

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities DEHN + SÖHNE DEHNconductor System No Problems with Proximities DEHNconductor System - New Possibilities for controling Proximities. For preventing dangerous flashovers among parts of external lightning

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

14. Tools and Software

14. Tools and Software 14. Tools and Software System overview: Geberit welding machine MEDIA 160 and tools... 364 System overview: Geberit welding machine UNIVERSAL 315 and tools... 365 14.1 Tools for Geberit Silent-db20 / Geberit

More information

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-...

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: 1996. No.: SE-... Installation guide for the SafeLine type anchorage device Tested in compliance with EN 795: 1996 No.: SE-... Version: 09.10.2008 SE 67 Subject to technical alterations! Contents 1. General information

More information

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family

More information

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION SPRINGLOK SYSTEM PRODUCT DESCRIPTION FEATURES & BENEFITS Fry Reglet offers five flashing systems, each tailored for a particular type of substrate so you can get exactly what you need. SM Surface mounted

More information

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since

More information

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink. The unit will start automatically. Please pay particular

More information

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs. Skylight Installation Instructions This document provides instruction and guidelines for installation of both curb mount (CM) and self flashing (SF) unit skylights on flat, pitched (> or equal to 3/12

More information

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced

More information

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS SECTION 02720 SANITARY SEWER AND STORM DRAIN SYSTEMS PART 1 GENERAL 1.01 SECTION INCLUDES A. The requirements for pipe material and installation in sewer and drainage collection systems. All materials

More information

MAXFLOW SYPHONIC DRAINAGE SYSTEM

MAXFLOW SYPHONIC DRAINAGE SYSTEM Tamakiş Sifonik Yagmur Suyu Toplama Sistemleri Inşaat San.ve Tic Ltd, STI Park Maya Sitesi Maya Meridyen Iş Merkezi No 2 Kat:7 Akatlar Istanbul 34335 Turkey Tel: 00 90 212 352 4600 Fax: 00 90 212 352 3666

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

1. Description. 2. List of Accessories included A B C F G H

1. Description. 2. List of Accessories included A B C F G H 1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to

More information

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 23 05 29 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe hangers and supports. 2. Hanger rods. 3. Inserts. 4. Flashing. 5. Equipment

More information

1 Introduction to the Recommendations and their Application Principles

1 Introduction to the Recommendations and their Application Principles 1 Introuction to the Recommenations an their Application Principles 1.1 National an International Regulations for Piling Wors (1) Since the implementation ofdin EN 1997-1:2009-09: Eurocoe 7: Geotechnical

More information

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS 174-180 PHILLIP STREET, SYDNEY July 2008 1.0 SCOPE These guidelines describe the way in which air conditioning units shall be installed or replaced

More information

HDA -----------------------------------------------------------

HDA ----------------------------------------------------------- ----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS

More information

SECTION 1040 GUARDRAIL, END TERMINALS, ONE-STRAND ACCESS RESTRAINT CABLE AND THREE-STRAND GUARD CABLE MATERIAL

SECTION 1040 GUARDRAIL, END TERMINALS, ONE-STRAND ACCESS RESTRAINT CABLE AND THREE-STRAND GUARD CABLE MATERIAL SECTION 1040 GUARDRAIL, END TERMINALS, ONE-STRAND ACCESS RESTRAINT CABLE AND THREE-STRAND GUARD CABLE MATERIAL 1040.1 Scope. This specification covers guarrail, en terminals, one-stran access restraint

More information

your reliable partner EAS -Compact Backlash-free Torque Limiting Clutches K.490.V14.EN

your reliable partner EAS -Compact Backlash-free Torque Limiting Clutches K.490.V14.EN ES -Compact Backlash-free Torque Limiting Clutches K.490.V4.EN www..com We safeguar the movements of this worl Specialists for power transmission for more than a century mayr power transmission is one

More information

Terminal Boxes Series 8146

Terminal Boxes Series 8146 Series > Enclosures in shock-resistant glass fibre reinforced polyester resin > basic enclosure sizes various heights > Fitted according to the customer's requirements > For terminals up to max. 00 mm

More information

Flue Installation. High Efficiency Condensing Boilers

Flue Installation. High Efficiency Condensing Boilers Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

L mm. 12 100 M12x1 163.120.11 14 100 M12x1 163.140.11 16 100 M12x1 163.160.11 TECHNICAL DETAILS: - Super strength steel. L mm

L mm. 12 100 M12x1 163.120.11 14 100 M12x1 163.140.11 16 100 M12x1 163.160.11 TECHNICAL DETAILS: - Super strength steel. L mm aw blaes lot an mortise boring bits 163 12 100 M12x1 163.120.11 14 100 M12x1 163.140.11 16 100 M12x1 163.160.11 TECHNCA ETA: - uper strength steel. - 2 HW precision groun cutting eges [Z2]. HW Z2 RH APPCATON:

More information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association Air-Conditioning, Heating, and Refrigeration Institute Sheet Metal and Air-Conditioning Contractors National Association GUIDELINE B-1997 ACKNOWLEDGEMENT These guidelines for Roof Mounted Outdoor Air-

More information

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE

More information

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23 Application Pressure regulators for set points from 5 mbar to 28 bar Valves in nominal sizes DN 15 to 100 Nominal pressures

More information

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation

More information

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Shower and Floor Gullies Channel Drain and Tile Drain SECTION Shower and Floor Gullies Channel Drain and Tile Drain SECTION 2 Shower and Floor Gullies, Channel Drain and Tile Drain 29 General Information Shower and Floor Gullies McAlpine has responded to market conditions

More information

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance 02/15 Labko GRP cesspools Instructions for installation, operation and maintenance Reliable solutions Wastewater treatment systems Contents 1 LABKO CESSPOOLS... 3 1.1 GENERAL... 3 1.2 IMPORTANT TO KNOW

More information

Simple machines. Law of Simple Machines. Resistance Force x resistance distance = effort force x effort distance

Simple machines. Law of Simple Machines. Resistance Force x resistance distance = effort force x effort distance Simple machines A simple machine is a evice that requires only the force of a human to perform work. One of the properties of a simple machine is that it can be use to increase the force that can be applie

More information

swimming pool accessories

swimming pool accessories 76 swimming pool accessories 77 Dolphin pool cleaners Dolphin Plus Battery Cordless pool cleaner with lithium ion battery Cleans the pool in 1.5 hours Special programs Clogged filter bag indicator Incl.

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

39HQ Airovision Air Handling Units

39HQ Airovision Air Handling Units 39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport

More information

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT 2003-2014 CHEVROLET/GMC VANS FOR (For NEW 2007 ALL WHITE KWIK-KITS ONLY) Warning do not attempt to install A/C units unless you are experienced with servicing

More information

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN 05.2015 www.rehau.com/relazzo

RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE. Construction Automotive Industry. REHAU R20680 EN 05.2015 www.rehau.com/relazzo Construction Automotive Industry RELAZZO DECKING THE TERRACE. INSTALLATION GUIDE REHAU R20680 EN 05.2015 www.rehau.com/relazzo Scan the QR code and learn more: RELAZZO DECKING THE TERRACE. Installation

More information

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.

More information

INFRARED QUARTZ WALL HEATER

INFRARED QUARTZ WALL HEATER INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this

More information

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls

Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre- insulated pipe systems ecoflex Wall Penetration installation guide Ecoflex Wall Penetration Systems: An efficient, sustainable solution for penetrating concrete or block walls Pre-insulated Pipe Systems

More information

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: [email protected]

More information

Packaged Terminal Air Conditioner Wall Sleeve Installation

Packaged Terminal Air Conditioner Wall Sleeve Installation Installation & Maintenance Data IM 1196 Group: PTAC Part Number: 910141799 Date: October 2013 Packaged Terminal Air Conditioner Installation x 42" PGAN with Top-Mounted Hydronic Heat Note: Installation

More information

PERIMETER FLASHING. Table of Contents

PERIMETER FLASHING. Table of Contents FM Global Property Loss Prevention Data Sheets 1-49 February 1985 Revised September 2000 Page1of25 PERIMETER FLASHING Table of Contents Page 1.0 SCOPE... 3 1.1 Changes... 3 2.0 LOSS PREVENTION RECOMMENDATIONS...

More information

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. Roofing Systems There are many different systems, each with it's own special requirements and benefits. Browse through all the options below. BUR (Built-Up Roofing) Built-Up-Roofing, BUR is a roof that

More information

Welcome: What is U Drain? Drain Materials. Flow

Welcome: What is U Drain? Drain Materials. Flow Welcome: Thank you for looking into the U Drain floor drain system. This paper will explore the functional features of the U Drain and why it is superior to other grated systems in the marketplace. We

More information

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit. 1. Description The macerating system of this unit is installed in a case, specifically designed for horizontal outlet spigots. This macerator is manufactured in a factory which is quality certified to

More information

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE 86 :: Certificate in Construction Supervision (CIVIL) 12 ROOF 12.1 INTRODUCTION The structure provided to cover the house surface (floor) is known as roof. For different situation and requirement, it is

More information

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork HVAC - Fire protection of metal ductwork Fire protection Thermal insulation Isover ULTIMATE TM Protect - Fire protection

More information

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES

GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES GAS DISTRIBUTION PRODUCTS STEEL SERVICE TEES CONTINENTAL INDUSTRIES ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

1. Geo Vertical 2. Geo Horizontal

1. Geo Vertical 2. Geo Horizontal 1 2 1. Geo Vertical 2. Geo Horizontal 1 2 3 1. Geo Vertical 2. Geo Vertical with towel rail 3. Geo Vertical with cover plate Geo Vertical 47 Geo Vertical Dimensions Connections Range GEVW_Geo Vertical

More information

PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724.

PB accessories. PB accessories. Labelling option. Order Information B4-2728. Printed board handle A BZA42727 BZA42724. Printed board handle A Assembly behind front panels Only use printed board handle in conjunction with printed board retainer A (6087-097) Insertion and extraction function Labelling option B4-2728 Item

More information

MAINTAINING ELECTRIC MOTORS USED FOR IRRIGATION

MAINTAINING ELECTRIC MOTORS USED FOR IRRIGATION MAINTAINING ELECTRIC MOTORS USED FOR IRRIGATION F. Richar Bear, Agricultural Equipment, Structures an Electricity Robert W. Hill, Biological & Irrigation Engineering August 2000 ENGR/BIE/WM/06 Electricity

More information

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure ACO Water Management: Civils + Infrastructure Uniclass L3 + L735 CI/SfB (5.5) EPIC J343 ACO MultiDrain MD ACO MultiDrain MD Medium duty channel drainage system ACO MultiDrain MD Introduction to the ACO

More information

iglidur PRT Slewing Ring Bearing

iglidur PRT Slewing Ring Bearing igliur igliur Slewing Ring Bearing Stanar range Completely maintenance-free Easy installation, intercangeable sliing pas ig wear resistance For ig loa capacity, ig stiffness Available as stainless steel

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

1 DESIGN FACTORS THE RUBEROID BLUE BOOK 1

1 DESIGN FACTORS THE RUBEROID BLUE BOOK 1 1 DESIGN FACTORS 1.1 FALLS AND DRAINAGE 1.2 THERMAL DESIGN 1.3 VAPOUR CONTROL DESIGN GUIDE 1.4 TRAPPED MOISTURE 1.5 MOVEMENT AND MEMBRANES 1.6 WIND 1.7 WIND ATTACHMENT DESIGN GUIDE 1.8 FIRE 1.9 ROOF RENEWAL

More information

Operating Instructions

Operating Instructions Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4

More information

12.1 Schlüter -KERDI-BOARD

12.1 Schlüter -KERDI-BOARD I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter

More information

Springlok Flashing System

Springlok Flashing System Springlok Flashing System Why Fry Reglet? Fry Reglet s comprehensive selection of moisture prevention products offer the ultimate in protection from the elements. Available nationwide in a variety of materials

More information

MultiPost-AP anchorage device

MultiPost-AP anchorage device MultiPost-AP anchorage device MultiPost anchorage point Type 1 Fixing on reinforced concrete with large, 360 rotating stainless steel lifting eye for the simultaneous securing of max. 2 persons. This can

More information

SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS

SECTION 08000 STORM DRAINAGE TABLE OF CONTENTS SECTION 08000 STORM DRAINAGE 08010 DESIGN A. Location B. Sizing TABLE OF CONTENTS 08020 MATERIALS A. Pipe Materials B. Structure Materials C. Installation D. Inlets and Outlets 08030 INSPECTIONS AND TESTING

More information

FLAT ROOF DRAINAGE AND PIPE SYSTEMS

FLAT ROOF DRAINAGE AND PIPE SYSTEMS FLAT ROOF DRAINAGE AND PIPE SYSTEMS 1. Principles 1.1 Fields of application Flat roof drains collect the rain water from flat roofs, multi-storey car parks, green roofs and terraces. The rain water is

More information

TECHNICAL SPECIFICATION

TECHNICAL SPECIFICATION THOMAS - G-FLEX GFLEX TECH SPEC CONNECTING INNOVATION JOHANNESBURG TEL: +27 11 794 7594 CAPE TOWN TEL: +27 21 556 5258 POLOKWANE TEL: 015 298 9142 DESIGNER, MANUFACTURER AND DISTRIBUTOR OF PIPE CONNECTION,

More information

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT GENERAL INFORMATION 1.1 This section applies to piping systems for chilled water, hot water, condenser water, steam, condensate return, fuel oil, refrigerant

More information

Isola Steel Gutters Strength and design for extreme climate!

Isola Steel Gutters Strength and design for extreme climate! Isola Steel Gutters Strength and design for extreme climate! Dry and healthy buildings Isola Steel Gutters Steeled against wind and weath The four seasons Wide temperature variations and highly variable

More information

FLAT ROOF BOX SPAN CARPORTS

FLAT ROOF BOX SPAN CARPORTS AGS/NC/03 FLAT ROOF BOX SPAN CARPORTS Thank you for choosing this quality product. We strongly recommend that you read these instructions thoroughly. Please take your time and do not rush the erection

More information

Fall Protection Solutions

Fall Protection Solutions P R O V I D I N G S A F E T Y S O L U T I O N S W O R L D W I D E Fall Protection Solutions COLLECTIVE PROTECTION KEEGUARD FREE STANDING GUARD RAIL APPROVED BY CERAM AND APAVE KEE DOME SKYLIGHT FALL PROTECTION

More information

How To Build A Gambrel Roof And A Gable End Roof

How To Build A Gambrel Roof And A Gable End Roof Dutch Gable or Gambrel Roof and The Scotch Valley The folowing pages are an extract from Carp 12 text TAFE NSW Construction and Transport Division 71 HIP and VALLEY ROOFING GAMBREL / DUTCH GABLE The effect

More information

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING 60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed

More information

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II 1 For your safety Table of Contents 1 For your safety... 3 1.1 About this manual... 3 1.2 Designated use... 3 1.3 Qualification

More information

MONDOATHENS BASKETBALL SET (Reference PK110)

MONDOATHENS BASKETBALL SET (Reference PK110) MONDOATHENS BASKETBALL SET (Reference PK110) DESCRIPTION The MONDOATHENS backstop unit is mainly designed for multi-sports pavilions and installations where the highest-level basketball competitions are

More information

Mechanical arms, belts and sheets

Mechanical arms, belts and sheets Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black

More information

Calculating Viscous Flow: Velocity Profiles in Rivers and Pipes

Calculating Viscous Flow: Velocity Profiles in Rivers and Pipes previous inex next Calculating Viscous Flow: Velocity Profiles in Rivers an Pipes Michael Fowler, UVa 9/8/1 Introuction In this lecture, we ll erive the velocity istribution for two examples of laminar

More information