Non-Contact Safety Switches CES-AR/CET-AR



Similar documents
Safe switching and monitoring Solenoid Interlocks

Safety Relays ESM/ESM-F

Combi B Alarm box. Mounting instructions

Contact expansion modules

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

SAFETY LIGHT CURTAINS

Encoder WDGI 58H.

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

E-STOP relays, safety gate monitors

Technical Data. Dimensions

Pressure transmitter For general industrial applications Model A-10

PNOZsigma - Base units

E-STOP relays, safety gate monitors

Modular I/O System Analog and Digital Interface Modules

Cable Plug acc. to DIN EN , Form A

Air damper actuators

Safety automation solutions

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

MINI MCR-SL-R-UI(-SP)

Contact expander modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Safety technique. Emergency stop module BO 5988 safemaster

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

picomax The Pluggable Connection System

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Safety detection solutions

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Combi switchbox with integrated 3/2 way pilot valve

mecotron Safety relay ESTOP-2 For emergency stop monitoring

General 1-2-Opto-electronics Safety Switches 4-Emergency

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

OPERATING INSTRUCTIONS

Technical Data. Dimensions

Assisted lift operated 2/2-way solenoid valves Type EV250B

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Fieldbus slave modules with I/Os, DIO

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Digital input modules

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

E-STOP relays, safety gate monitors

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

SMS 4 / SMS 5 safety mat Product information

Electronic Pressure Switch EDS 300

Line-Mounted Valves L Series

Inductive sensor NI10-M18-Y1X-H1141

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

CONFIGURABLE SAFETY RELAYS

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

Proportional pressure regulators VPPE

Electrical connection

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Givare NC-SRS 280 och 880

Series 6000 Torque measured metal bellow coupling

Digital display DA 48

TX OPEN RS232/485 module

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

E-STOP relays, safety gate monitors

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

2/2 and 3/2 Way Size 6 Seat Valves

Linear actuator Econom 0. Our intelligent model: Econom 0. Econom 0

Encoder WDG 58B.

Cross-beam scanning system to detect slim objects. 100 mm in

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

01. HARTING RJ INDUSTRIAL RJ45 ETHERNET CONNECTORS

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

BOS 73K... BOS 74K...

HERZ-Thermal Actuators

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

3 Port Solenoid Valve

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

How To Use A Flowmeter

Redundancy Module QUINT-DIODE/40

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Fast, reliable, ultra-precise. My-Com precision switches.

Electric Rotary Actuator - On/Off or programmable control actuator

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

CONFIGURABLE SAFETY RELAYS

Transcription:

Non-contact safety switches CET-AR-... with guard locking and guard lock monitoring ) switch with guard locking and integrated evaluation electronics Locking force up to 00 N Up to 0 switches in series Short circuit monitoring safety (semiconductor ) Up to category / PL e according to EN ISO 9 Non-contact safety switch CET-AR... with plug connectors M 0 M Cat. PLe...0 With escape release 0 LED LED STATE D Mechanical release, SW 9 Norm. position escape release Release by pressing ± mm,, 0, CET.-AR...CRA...,, <>, For possible combinations see page 9 Approach direction Horizontal Can be adjusted in 90 steps switch The safety switch CET is only allowed to be operated in conjunction with the actuator CET- A-BWK-0X. Important: The actuator must be ordered separately. Actuator CET-A-BWK-0X separately Lift tappet with read head 90, CET.-AR...CDA.... For M screw DIN 0 / ISO, 0, With angle connectors Unicode evaluation Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught-in. Only the last actuator taught-in is detected. New actuators are taught by connecting the teach-in input to U B (only version with teach-in input). Multicode evaluation Every suitable actuator is detected by the evaluation unit. Mechanical release Is used for releasing the guard locking with the aid of a tool. The mechanical release must be sealed to prevent tampering (for example with sealing lacquer). Escape release (optional) Is used for the manual release of the guard locking from within the danger area without tools. Wire front release (optional) The wire front release permits remote release of the guard locking via a pull rope. Flexible routing of the pull rope permits release of the guard locking in inaccessible installation situations. Solenoid operating voltage DC V +0%, -% Guard locking types CET Guard locking by spring force Release by applying voltage to the guard locking solenoid. CET CET CET Guard locking by solenoid force Guard locking by applying voltage to the guard locking solenoid. Release by spring force. Guard locking by spring force with door monitoring output. Function as for CET-AR, however here the door position is also monitored. The door monitoring output D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output D remains set also with guard locking active. Guard locking by solenoid force with door monitoring output. Function as for CET-AR, however here the door position is also monitored. The door monitoring output D is set to HIGH as soon as the actuator protrudes beyond the extended lift tappet (state: door closed, guard locking not active). The output D remains set also with guard locking active. LED function display LED State Status LED LED D Diagnostics LED LED red freely configurable LED green freely configurable Connection cable see page Additional connections Monitoring output (semiconductor) Reset input Category according to EN ISO 9 Due to two redundant design semiconductor (safety ) with internal monitoring suitable for: Category / PL e according to EN ISO 9 Important: To achieve the stated category in accordance with EN ISO 9, both safety ( and ) must be evaluated. The category is dependent on the installation position of the safety switch: Installation position Head upward Head downward or horizontal Achievable category and PL acc. to EN ISO 9- / PL e / PL e ) No UL approval for CET of for version with plug connector RC For ordering table see page /.

Non-contact safety switch CET-AR... with plug connector RC Cable outlet left Cable outlet right 0, 0,,, For elbow connector see page and Actuator CET-A-BWK-0X for safety switch CET-AR

Wiring diagrams DC V -F -F 0V UCM LED LED UCM J 0V Connected load CET-AR GND Connection example for separate operation, version with teach-in input DC V -F -F START 0V UCM LED LED UCM Y 0V Connected load Feedback loop CET-AR GND Connection example for separate operation, version with start button and feedback loop DC V -F -F 0V UCM LED LED UCM 0V Connected load CET-AR GND Connection example for separate operation, version without feedback loop and without

switch CET.-AR-...-SG-... (with plug connectors M) Terminal assignment Plug connector (view of connection side) S. S. S. S. S. x M S. S. S. S. S. S. S. Designation Door monitoring Wire color PIN Function output Connection cable ) With Without S. Enable input for channel WH S. U B Operating voltage AR electronics, V DC BN S. output, channel GN S. output, channel YE S. Monitoring output GY S. Enable input for channel PK S. 0 V U B Operating voltage AR electronics 0 V BU S. Reset input RD S. Depending on version S. Depending on version S. S. 0 V U CM Operating voltage guard locking solenoid 0 V BN D LED S. LED LED LED red, freely configurable ), V DC Door monitoring output (only CET-AR and CET-AR) LED red or LED green, freely configurable ), V DC S. U CM Operating voltage guard locking solenoid, V DC BK J Y - ) Only for standard EUCHNER connection cable ) Can vary depending on version. See data sheet. Version with teach-in input: to teach-in a new actuator, connect to V DC; in normal operation connect to 0 V. Version with feedback loop: if the feedback loop is not used, connect to V DC Version without feedback loop and without teach-in output: this connection must be connected to 0 V. WH BU GY

Ordering table CET.-AR-...-SG-... (with plug connectors M) Order no. / item Closed-circuit current principle Open-circuit current principle Door monitoring output Unicode Multicode Single insertion slide Double insertion slide Teach-in input Feedback loop Escape release Bowden wire Lockout mechanism 0 CET-AR-CDA-AH-0X-SG-0 l l l l 0 CET-AR-CRA-AH-0A-SG-0 l l l l l mm 09 CET-AR-CRA-AH-0F-SG-09 l l l CET-AR-CRA-AH-0F-SG-C- l l l l 00 CET-AR-CRA-AH-0S-SG-00 l l l l 0 CET-AR-CRA-AH-0X-SG-0 l l l l l mm CET-AR-CRA-AH-0X-SG-C- l l l l l l mm 0 CET-AR-CRA-CH-0F-SG-0 l l l l mm 0 CET-AR-CRA-CH-0S-SG-0 l l l l 0 CET-AR-CRA-CH-0X-SG-0 l l l 090 CET-AR-CRA-CH-0X-SG-C90-090 l l l l 09 CET-AR-CDA-CH-0X-SG-09 l l l 090 CET-AR-CRA-AH-0S-SG-090 l l l l 00 CET-AR-CRA-AH-0X-SG-00 l l l l 099 CET-AR-CRA-CH-0F-SG-C-099 l l l l 0 mm 00 CET-AR-CRA-CH-0X-SG-00 l l l 090 ) CET-AR-CRA-AH-0X-SG-090 l l l l 0 ) CET-AR-CRA-CH-0X-SG-C90-0 l l l l l 090 ) CET-AR-CRA-CH-0F-SG-C90-090 l l l l l l mm 090 ) CET-AR-CRA-CH-0X-SG-090 l l l l 090 ) CET-AR-CRA-CH-0F-SG-090 l l l l l mm ) No UL approval

switch CET.-AR-...-SH-... (with plug connector RC) Terminal assignment Plug connector (view of connection side) RC with screen bonding clamp 9 0 9 Depending on version PIN Designation Function U CM Operating voltage guard locking solenoid, V DC Enable input for channel Enable input for channel output, channel output, channel U B Operating voltage AR electronics, V DC Reset input D Door monitoring output (only CET-AR and CET-AR) 9 - n.c. 0 Monitoring output - n.c. FE Function earth J Y - Version with teach-in input: to teach-in a new actuator, connect to V DC; in normal operation connect to 0 V. Version with feedback loop: if the feedback loop is not used, connect to V DC Version without feedback loop and without teach-in output: this connection must be connected to 0 V. - n.c. LED LED red, freely configurable, V DC LED LED green, freely configurable, V DC - n.c. 0V U CM Operating voltage guard locking solenoid 0 V 9 0V U B Operating voltage AR electronics 0 V Ordering table CET.-AR-...-SH-... (with plug connector RC) Order no. / item Closed-circuit current principle Open-circuit current principle Door monitoring output Unicode Multicode Single insertion slide Double insertion slide Teach-in input Feedback loop Escape release Bowden wire Lockout mechanism 00 ) CET-AR-CRA-AH-0X-SH-00 l l l l 09 ) CET-AR-CRA-AH-0F-SH-C-09 l l l l l 0 mm 00 ) CET-AR-CRA-CH-0X-SH-00 l l l 00 ) CET-AR-CRA-AH-0X-SH-00 l l l l 00 ) CET-AR-CRA-CH-0X-SH-00 l l l 00 ) CET-AR-CRA-AH-0X-SH-00 l l l l l 00 ) CET-AR-CRA-CH-0X-SH-00 l l l l ) CET-AR-CRA-AH-0X-SH- l l l l l l 0 mm ) No UL approval Accessories Ordering table Designation Version/usage Order no. / item Actuator for read head CET-AR screws M x Handle for wire front release (Bowden) Locking force 00 N (incl. safety screws) For actuator CET-A-BWK-0X (replacement) packaging unit: 00 ea. For safety switch CET-AR with wire front release (bowden) 09 CET-A-BWK-0X 0 Mx/V00 0999 Handle for wire front release (Bowden)

Technical data non-contact safety switches CET-AR... switch Parameter Value Unit min. typ. max. General Material, slide Stainless steel Material, safety switch housing Die-cast aluminum Installation position Any (recommendation: switch head downward) Degree of protection IP / IP with plug connector RC (screwed tight with the related mating connector) class III Degree of contamination Mechanical life x 0 operating cycles Ambient temperature at U B -0 - + C Actuator approach speed, max. 0 m/min Locking force F max 00 N Locking force F Zh in acc. with GS-ET-9 F Zh = F max /. =,000 N Weight Approx..0 kg Degrees of freedom (actuator in recess) X, Y, Z ± mm Connection type (depending on version) plug connectors M, and -pin plug connector RC, 9-pin (as yet no UL approval) Operating voltage U B (reverse polarity protected, regulated, residual ripple < %) ± % V DC Current consumption I B 0 ma For the approval according to UL the following applies Operation only with UL class power supply, or equivalent measures Switching load according to UL DC V, class External fuse (operating voltage U B ) 0. - A External fuse (solenoid operating voltage U CM ) 0. - A V DC Resilience to vibration In acc. with EN 09-- EMC protection requirements As per EN IEC 09-- / Semiconductor, p-switching, short circuit-proof HIGH U /U U B -. - U B - Output voltage U /U ) LOW U /U 0 - Switching current per safety output - 00 ma Utilization category according to EN 09-- DC- V 00 ma Caution: must be protected with a free-wheeling diode in case of inductive loads Classification acc. to EN IEC 09-- PDF-M Switching frequency 0. Hz Repeat accuracy R acc. to EN IEC 09-- 0 % Monitoring and D (optional) (p-switching, short circuit-proof) Output voltage 0. x U B - U B V DC Max. load - - 0 ma Teach-in input J or input feedback loop Y HIGH - U CM V LOW 0 - Solenoid Solenoid operating voltage U CM (reverse polarity protected, regulated, residual ripple < %) DC V +0%/-% Current consumption solenoid I CM 00 ma Power consumption 0 W Duty cycle 00 % Freely configurable LEDs ) LED red, LED green Operating voltage 0. -. V DC Reliability values according to EN ISO 9- Head downward or horizontal Head upward Category Performance Level (PL) e e PFH d. x 0-9 / h.9 x 0 - / h Mission time 0 0 years ) Values at a switching current of 0 ma without taking into account the cable lengths. ) Can vary depending on version. See data sheet. Actuator Parameter Value Unit min. typ. max. Housing material Stainless steel Installation position Active face opposite read head Degree of protection according to IEC/EN 09 IP Mechanical life x 0 operating cycles Ambient temperature -0 - + C Locking force, max. (locked) 00 N Weight Approx. 0. kg Stroke max. mm Power supply Inductive, via read head

Connection cables Flying lead M female plug -pin Flying lead M female plug -pin Flying lead M female plug -pin Plug on both ends M male and female plug -pin View of connection side View of connection side View of connection side View of connection side Socket Crimped ferrules Plug = WH = BN = GN = YE = GY = PK = BU O V = RD = WH = BN = GN = YE = GY = PK = BU O V = RD = BN U B = WH / = BU 0 V = BK / = GY = BN U B = WH / = BU 0 V = BK / = GY 9

Ordering table Series Comment Order no. M connection cable PUR -core, flying lead for the connection of a CES-AR-C. M connection cable PVC -core, flying lead for the connection of a CES-AR-C. M connection cable PVC -core, flying lead for the connection of a CES-AR-C0/ CES-AR-C. M connection cable PVC -core, flying lead for the connection of the last CES-AR-C0/CES-AR-C. in a switch chain M connection cable PVC -core, connectors at both ends for the connection of two CES-AR-C0/ CES-AR-C. in a switch chain M female plug -pin, length m M female plug -pin, length 0 m M female plug -pin, length 0 m M female plug -pin, length m M female plug -pin, length 0 m M female plug -pin, length m M female plug -pin, length 0 m M female plug -pin, length m M female plug -pin, length 0 m M female plug -pin, length 0 m M female plug -pin, length m M female plug -pin, length 0 m M female plug -pin, length 0 m M female plug -pin to M male plug, length m M female plug -pin to M male plug, length 0 m M female plug -pin to M male plug, length 0 m 0 C-M0F0-0X0PU0,0-ES-0 0 C-M0F0-0X0PU0,0-ES-0 0 C-M0F0-0X0PU0,0-ES-0 09 C-M0F0-0X0PV0,0-ES-0 09 C-M0F0-0X0PV0,0-ES-0 09 C-M0F0-0X0PV0,0-ES-0 0 C-M0F0-0X0PV0,0-ES-0 00 C-MF0-0X0PV0,0-ZN-00 00 C-MF0-0X0PV0,0-ZN-00 009 C-MF0-0X0PV0,0-ZN-009 00 C-MF0-0X0PV0,0-ZN-00 00 C-MF0-0X0PV0,0-ZN-00 00 C-MF0-0X0PV0,0-ZN-00 000 C-MF0-0X0PV0,0-MM0-000 00 C-MF0-0X0PV0,0-MM0-00 00 C-MF0-0X0PV0,0-MM0-00 0

Bridging connector/y-distributor Bridging plug Male plug -pin Y-distributor M with connection cable x -pin, x -pin Y-distributor M x -pin, x -pin View on connection side Mx Mx, ( ) (figure similar) Mx 00 09 max. A B Mx Ø, Mx Ø, Wiring Bridging plug Plug Pin Function Mx Pin Socket Function U B U B 0 V 0 V Plug 0,, Socket Pin Function Pin Function U B U B 0 V 0 V Note:: For the connection to the Y-distributor, -pin standard plug connectors M can be used. Note:: For the connection to the Y-distributor, -pin standard plug connectors M can be used. Important: Switch chains must always be terminated with a bridging plug. Switch chains up to maximum 00 m are allowed taking into account the voltage drop due to the cable resistance (see System Manual). Ordering table Series Comment Order no. Bridging plug Y-distributor M with connection cable Y-distributor M M plug connector -pin M, x -pin, x -pin M, x -pin, x -pin 09 Bridging plug 9 Y-distributor with connection cable 09 Y-distributor M

Connection cables RC for CET-AR Female plug RC with cable -pin + PE Female plug RC with cable halogen-free -pin + PE Inserted SW0 Ø, ±0, Ø With screen bonding clamp 9 0 View of connection side, socket 9 9 Inserted, ±0, With screen bonding clamp 9 0 View of connection side, socket 9 Female plug RC angled with cable -pin + PE Female plug RC angled with cable halogen-free -pin + PE 0, SW0 SW M0x, With screen bonding clamp 9 0 View of connection side, socket 9 0 0 0, ±0, With screen bonding clamp 9 0 View of connection side, socket 9 Assignment connection cable RC for CET-AR Pin Core color Wire cross-section [mm] Pin Core color Wire cross-section [mm] VT 0. BK 0. RD 0. GN/YE.0 GY 0. PK 0. RD/BU 0. BN/GY 0. GN 0. BN/YE 0. BU.0 BN/GN 0. GY/PK 0. WH 0. GN/WH 0. YE 0. 9 YE/WH 0. 9 BN.0 0 GY/WH 0.

Ordering table Designation Cable length [m] Order no./item. 09 RCEF,M-C 09 RCEFM-C 00 RCEFM-C 00 Female plug RC RCEFM-C with cable PUR 099 0 for CET-AR RCEF0M-C -pin + PE 00 RCEFM-C 0 09 RCEF0M-C 09 RCEFM-C 0 0999 RCEF0M-C. 09 RCEF,MF-C 09 RCEFMF-C Female plug RC with cable PUR halogen-free, suitable for drag chain for CET-AR -pin + PE Designation Female connector RC angled with cable PUR for CET-AR -pin + PE Female connector RC angled with cable PUR halogen-free suitable for drag chain for CET-AR -pin + PE 0 0 Cable length [m]. 0 0. 0 0 Cable outlet left 0990 RCWF,ML-C 0990 RCWFML-C 00 RCWFML-C 009 RCWFML-C 0990 RCWF0ML-C 000 RCWFML-C 0990 RCWF0ML-C 099 RCWFML-C 099 RCWF,MLF-C 099 RCWFMLF-C 099 RCWFMLF-C 099 RCWFMLF-C 0999 RCWF0MLF-C 090 RCWFMLF-C 090 RCWF0MLF-C 09 RCWFMLF-C 09 RCEFMF-C 09 RCEFMF-C 09 RCEF0MF-C 09 RCEFMF-C 099 RCEF0MF-C 0990 RCEFMF-C Order no./item Cable outlet right 0990 RCWF,MR-C 09909 RCWFMR-C 09 RCWFMR-C 09 RCWFMR-C 0990 RCWF0MR-C 09 RCWFMR-C 099 RCWF0MR-C 099 RCWFMR-C 099 RCWF,MRF-C 099 RCWFMRF-C 099 RCWFMRF-C 099 RCWFMRF-C 0900 RCWF0MRF-C 090 RCWFMRF-C 090 RCWF0MRF-C 09 RCWFMRF-C

Female connector RC angled CET-AR Female connector RC angled -pin + PE, direction of the cable outlet can be adjusted Inserted With screen bonding clamp Cable outlet left Direction of the cable outlet can be adjusted Cable outlet right SW0 SW 9 0 9 0 View of connection side, socket M0x, Ordering table ) Crimp contacts included Series Comment Order no. RC ) -pin + PE WF Female plug angled Replacement pin crimp contacts Wire cross-section 9 x 0. - mm 0 RCWF 0909 Pin crimp contact RCM

Miscellaneous accessories Mechanical key release for safety switch CET Emergency unlocking for safety switch CET Cover for safety switch CET Mechanical key release for safety switches CET Mechanical key release The mechanical key release is used in combination with safety switch CET. It enables authorized personnel to actuate the mechanical release using the related key. The unlocking mechanism holds the solenoid in the "unlocked" position. A screw is used to fix the lock to the cover of the safety switch CET (over the mechanical release). The lock is identical locking. 0,, 0 Ø, Order safety switch CET separately keys included (for spare keys see ordering table below) Every safety switch in the CET series can be upgraded with the mechanical key release Emergency unlocking Using the emergency unlocking the safety switch can be unlocked manually. In the locked position of the emergency unlocking, a ball detent mechanism prevents unintentional unlocking of the safety switch due to vibration or similar effects. In the unlocked position of the emergency unlocking, an integrated bolt engages in a bore on the flange. To reset the emergency unlocking, first the bolt must be pressed inwards, out of the detent mechanism, using a tool. Emergency unlocking for safety switches CET 0, Cover With the CET cover, tampering with the safety switch CET is effectively prevented. The cover prevents the use of simple tools to manually press up the actuator. Cover for safety switch and actuator CET Cover for door hinge on left mirror image 9 <> 0 <> 0, Ø, (x) Ordering table Designation Use Version Order no / item Mechanical key release For safety switches CET Identical locking, incl. keys Replacement key For mechanical key release, identical locking keys, identical locking Emergency unlocking For safety switches CET Latching in both positions Cover For safety switches CET and actuators CET Door hinge right Door hinge left 090 Mechanical key release 099 Replacement key 0 Emergency unlocking CET 090 CET cover right 090 CET cover left

Mounting plate CET Mounting plate for safety switch CET for hinged or sliding doors Suitable for aluminum profiles 0... mm Horizontal and vertical mounting Made of aluminum Suitable for CET with escape release Mounting plate EMP-L-CET for safety switches CET Mounting plate EMP-B-CET for safety switches CET 0 9 0 0 9,, Material thickness 0 mm Material thickness 0 mm Ordering table Designation Use Order no / item Mounting plate EMP-L-CET Mounting plate EMP-B-CET screws for safety switches CES-AR-C.-... and actuators CES-A-BLN... For safety switches CET For actuators CET M x packaging unit 00 ea. for safety switches CES-AR-C.-... and actuators CES-A-BLN... 09 EMP-L-CET 09 EMP-B-CET 00 screws M x Installation example mounting plates EMP-.-CET Hinged door Sliding door Standard Alu-Profil Standard aluminium profile (0- mm) Standard Alu-Profil Standard aluminium profile (0- mm) x M x M x M x M x M x M x M Sicherheitsschrauben M (im Lieferumfang des Betätigers) screws M (included in delivery of actuator) x M Sicherheitsschrauben M (im Lieferumfang des Betätigers) screws M (included in delivery of readhead)

Connection examples CES-AR Important: To achieve the stated category in accordance with EN ISO 9, both safety ( and ) must be evaluated. Connection of a single CES-AR-C If a single CES-AR-C is used, connect the switch as shown in figure below. The output can also be connected here to a control system as a monitoring output. The switch can be reset via the input. To do this, a voltage of V is applied to the input for at least seconds. The supply voltage to the switches is interrupted during this time. If input is not used in your application, it should be connected to 0 V. DC V -F Connection of several CES-AR-C in series The switches are connected in series using plug connectors and Y-distributors. If, in this connection example, a safety guard is opened or if a fault occurs on one of the switches, the system shuts down the machine. A higher level control system can, however, not detect which safety guard is open or on which switch a fault has occurred. So that a control system can detect the status of each switch in a switch chain, the monitoring output must be connected separately for each switch. A special external evaluation unit is required for this purpose (see page 9). The switches can be reset via the input. To do this, a voltage of V is applied to the input for at least seconds. The supply voltage to the switches is interrupted during this time. If input is not used in your application, it should be connected to 0 V. Important: Switch chains must always be terminated with a bridging plug. DC V -F Stift/ connector (male) T-Stück/T-Connector Buchse/ conector (female) Stift/ connector (male) T-Stück/T-Connector Buchse/ conector (female) Stift/ connector (male) T-Stück/T-Connector Buchse/ conector (female) 0V 0V 0V 0V Connected load M plug-connector CES-AR # (-pin) GND Brückenstecker / Short-circuit plug Stift/ conetctor (male) CES-AR #n Plug-connector (-pin) CES-AR #n- Plug-connector (-pin) CES-AR # Plug-connector (-pin) Connected load GND

Connection examples CET-AR Important: To achieve the stated category in accordance with EN ISO 9, both safety ( and ) must be evaluated. Connection of a single CET-AR, version without feedback loop If a single CET-AR is used, connect the switch as shown in figure below. The output can also be connected here to a control system as a monitoring output. The switch can be reset via the input. To do this, a voltage of V is applied to the input for at least seconds. The supply voltage to the switches is interrupted during this time. If input is not used in your application, it should be connected to 0 V. DC V -F -F 0V UCM LED LED UCM 0V Connected load CET-AR GND Connection of a CET-AR in a CES-AR switch chain DC V START -F -F Stift/ connector (male) T-Stück/T-Connector Buchse/ connector (female) Stift/ connector (male) T-Stück/T-Connector Buchse/ connector (female) Brückenstecker / Short-circuit plug Stift/ connector (male) 0V UCM LED LED UCM Y 0V 0V 0V CES-AR #n- Plug-connector (-pin) CES-AR # Plug-connector (-pin) Connected load Feedback loop CET-AR #n GND Important: The subsystem CET-AR complies with PL e according to EN 9-. To integrate the subsystem in a category or structure, it is necessary to monitor the downstream load (the feedback loop must be monitored). These examples show only an excerpt that is relevant for connection of the CET system. The example illustrated here does not show complete system planning. The user is responsible for safe integration in the overall system.