LTV10 Series Composite Housing Accent



Similar documents
IN-GRADE C54 Accent 6350 HID Accent 6360 Cool-Lens. Well Lights Watt HID Up to 150 Watt Halogen or Incandescent

PGL5/6 - Parking Garage Luminaire Installation Instructions

CFL. Specifications. Compact Floodlights revision 11/13/14 kl_cfl_spec.pdf. Fixture Options: Approvals: Job: Fixture Catalog number: Mounting Options:

Invue ECM/EMM EPIC MEDIUM W

design Mario Cucinella MAXIWOODY

Nightspot A2 Floodlights for LEDs and high pressure discharge lamps

Low Bay LED Light - 250W Metal Halide Equivalent - 12 LEDs - 40 Watt High Output LEDs

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

AMERBRITE UNDERWATER WHITE LED POOL LAMP

morelux QUALITY HIGH & LOW BAY LIGHTING CATALOGUE 2003/04

ETC130 / 140 Inground Uplights - Gimbal LED. Presentation Overview

UNDERWATER LIGHTING FOUNTAIN REFLECTION POOL SWIMMING POOL

Nightspot High performance floodlights for discharge lamps and LEDs

commercial HID lighting table of contents LIGHTING

Outdoor Path of Egress Solutions Dual-Lite 1

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

In the following Temperature Profile Data Charts when a T code is used, this chart explains the temperature maximum (in degrees Celsius).

ALARI LED PARKING, ROADWAY & AREA LIGHTING

Weatherproof Products

Installation Instructions

LED High Bay Light 100W

Installation Instructions Hustler 6-BTV Trap Vertical

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Highbay and Lowbay LED Luminaires. Energy-efficient, low-maintenance lighting for commercial and industrial applications

Infrared Viewers. Manual

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

ROOF DRAINS TABLE OF CONTENTS

SECTION F HALOGEN LAMPHOLDERS HALOGEN LAMPHOLDERS Wilson Avenue, Toronto, Ontario, Canada, M9M 1A1 Ph: Fax:

denver elite bollard Patent Pending REGISTERED EUROPEAN DESIGN

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Superlight Compact Nano

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Dialight. Vigilant LED High Bay - UL for Indoor and Outdoor Industrial Applications

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

HALO H27RICT. 6" RECESSED DOWNLIGHTING Incandescent. eliminate need for separate wire nuts - simply strip supply wires and push in

SKYGUARD. Prisma design. H max 2,5 m. H min 0,46 m.

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Searchlights - Introduction

7 Watt Solar Charger Solar Panel

C2D LowBay: All the power, none of the bulk. C2D Advantage

INSTALLATION & OPERATION MANUAL LED

Dialight LED Lighting Fixture Catalog. for Industrial and Hazardous Locations

Chapter 3 Pre-Installation, Foundations and Piers

PC-Concrete Injectable Concrete Anchoring and Repair System

Wanda Technology Inc. Side Post Aluminum Umbrella OWNER S MANUAL

LIGHTING AQUAREVA SPECTRUM AMERLITE (SAM) SPECTRUM AQUALIGHT (SAL) AMERLITE AQUALUMINATOR. LED Lucy RGB transformers cx-1203 Smart Aqua Led Light

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

Note: All dimensions are nominal. All weights are for shipping purposes only. Availability is subject to change.

Mini-led spotlight with magnetic base

PAINT BOOTH LIGHTING

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS

Superlight Compact LED LED floodlights


OPEN OFFICE T8 HP FLUORESCENT HIGH PERFORMANCE LENSED

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

PRODUCT SPECIFICATION

V anguard. applications 5.1. vanguard vanguard. Assembly lines. Production areas. Gymnasia. Swimming pools. Clean areas. Food processing areas

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Sun Vinyl New Construction Windows Homeowner's Warranty

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

ISL-540 TBTS SERIES D EMERGENCY LIGHTING EQUIPMENT

SECTION STORM DRAIN SYSTEM

Select Radiators Installation Guide

SSNICLRG SSNICSM PLNICLRG PLNICSM

Nightscape High performance floodlights and spotlights for discharge lamps

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

ELECTRIC KNIFE SHARPENER

GE Lighting Solutions. Albeo LED Luminaire. Modular High & Low Bay Lighting. (ABHX - Series) imagination at work

Screw Plug Immersion Heaters

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTITUTIONAL BARRIER FREE SHOWER INSTALLATION

PARTS & SERVICE MANUAL for CONTEMPO SERIES WARMER LAMPS

James M. Pleasants Company

Installation & Maintenance Instructions

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

WE-EF LIGHTING North American Edition Inground Luminaires

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Installation PowerPoint for Grasscrete Formers

CLEAR-DIVISIONS VARIOFOLD

CLEAR-DIVISIONS APERTO

MEDMASTER EXTERNAL POWER SUPPLY

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Urban lighting luminaire ECOLO. Registered models - Design Massimo Sacconi. NERO e GRIGIO per marchi piccoli (ha il filo ingrossato)

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

GE Lighting. Evolve LED Wall Pack. N Series (EWNA) imagination at work

Super Slider ADJUSTABLE FROM Model #HD26229

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

Contents. Additional Hella Products White Noise Back-up Alarms Switches Camera Systems. Technical Data Hella Test Standards IP Ratings

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

CLEAR-DIVISIONS CENTERFOLD

Installation Instructions

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Spot on Lighting

DuroSite Series LED High Bay for Indoor and Outdoor Industrial Applications. Patent Pending

HIH-4000 Series Humidity Sensors

Fluxa Area floodlights for high pressure discharge lamps and LEDs

Transcription:

Catalog number: / / / Fixture Optics Lamp Mode Option - order assembled with fixture Specifications 16J" (412.8 mm) 2B" (54.0 mm) See page 2 See page 3 L" (19.1 mm) 13J" (336.6 mm) 3" (78.2 mm) 360 Optical Adjustment 25 (2) L" NPT 25 12L" DIA. (323.9 mm) LTV10 Series Composite Housing Accent Fixture Options: Ordered separately from fixture See page 3-4 Approvals: Date: Page: 1 of 6 Lens Ring: One-piece cast bronze, natural finish. (Optional standard stainless steel lens ring is also available.) Eight captive M" blackened stainless steel hex-socket cap screws. Lens: Clear tempered borosilicate glass, M" thick, flush with lens ring, slightly crowned. Lens Gasket: One-piece molded silicone, U-channel wraps completely around lens flange. Composite Housing: High temperature, compression molded, fiberglass impregnated, F" min. wall composite. Charcoal gray. No top lip to trap dirt and moisture. Solid brass knurled inserts molded-in to receive lens ring screws. Separate splice and ballast compartments, individual cast aluminum internal covers, with silicone gaskets. Two L" NPT in bottom, 33 cu in. splice area. Modular reverse draft design (top dia. smaller than bottom), body and ballast modules epoxy bonded. Optical System: SP and NF - Spot or narrow flood spun aluminum reflectors, specular Alzak, black Duranodic arc tube glare shield on SP only. (G12 base socket option available.) PR - for PAR38 reflector lamps. HID and Halogen sockets 4KV medium base. Optical systems are yoke mounted, 360 rotation, ±25 vertical adjustment, locking screws, black hi-temp finish gimbal ring. PL - GX24q-4 universal socket is provided for fluorescent. Electrical Module: High power factor ballast, -20 F starting, factory mounted and prewired to gasketed compartment cover. Wiring: Anti-siphon barriers on all wiring to and from ballast compartment. All components wire linked for ground, quick-disconnect for removal of optical system. Drive-over Durability: When installed in concrete (see page 5), fixture will withstand drive-over by vehicles weighing up to 5,500 lb. See page 6 for safety and warranty information. 3K" (88.9 mm) Hubbell Lighting, Inc. U.s. patents D410,295 AND D411,640 Listings and Ratings UL cul 1598 1 IP68 Rated CE 25C Ambient 1 Suitable for wet recessed KIM LIGHTING RESERVES THE RIGHT TO CHANGE SPECIFICATIONS WITHOUT NOTICE.

Page: 2 of 6 150 PMH 120 Standard Features Lamp Watts Lamp Type Line Volts PMH = Pulse Start Metal Halide HPS = High Pressure Sodium HAL = Halogen PL = Compact Fluorescent Fixture± Optics Lamp Mode Cat. No. l LTV10 HID Accent l SP Spot l NF Narrow FloodH Yoke mounted reflector and medium base socket for ED-17 HID lamp. 42PL operates one 26, 32, or 42 watt lamp at 120 thru 277 volts (50-60 Hz). l PR PAR Lamp Yoke mounted medium base socket for PAR38 HID reflector lamp. Pulse Start Metal Halide l 50PMH120 l 50PMH208 l 50PMH240 l 50PMH277 l 50PMH347 l 70PMH120 l 70PMH208 l 70PMH240 l 70PMH277 l 70PMH347 l 100PMH120 l 100PMH208 l 100PMH240 l 100PMH277 l 100PMH347 l 150PMH120 l 150PMH208 l 150PMH240 l 150PMH277 l 150PMH347 High Pressure Sodium l 70HPS120 1 l 70HPS208 1 l 70HPS240 1 l 70HPS277 1 l 70HPS347 1 l 100HPS120 1 l 100HPS208 1 l 100HPS240 1 l 100HPS277 1 l 100HPS347 1 l 150HPS120 1 l 150HPS208 1 l 150HPS240 1 l 150HPS277 1 l 150HPS347 1 Compact Fluorescent l 42PL120 1 l 42PL208 1 l 42PL240 1 l 42PL277 1 1 HPS and PL not available for PR optics. Cat. No. l LTV11 Halogen Accent l PR PAR Lamp Yoke mounted medium base socket for PAR38 halogen reflector lamp. l 250HAL120 250W maximum, lower wattage lamps may be used.

Page: 3 of 6 Optional Features G12 Base Socket Cat. No. l G12 socket Socket is available for 70W and 150W Pulse Start Metal Halide T-6 Bipin lamps. Brushed Stainless Steel Lens Ring Cat. No. l SS10 l SS10 (Assembled) One-piece standard brushed stainless steel replaces standard lens ring. Includes glass lens gasket and mounting screws. May be ordered separately. To order assembled with fixture, add to fixture Cat. No. - Example: LTV10/xx/xxxxxxxx/SS10 Half Shield Cat. No.l HS10 Half shield lens ring for directional glare control toward the viewer. One-piece cast bronze, replaces standard lens ring. Includes glass lens gasket and mounting screws. 164 4D" (117.5 mm) 24 Rock Guard Cat. No. l RG10 Rock guard lens ring for lens protection in vandal prone areas. One-piece cast bronze, replaces standard lens ring. Includes glass lens gasket and mounting screws. 1L" (44.5 mm) Trim Ring Cat. No. l TR10 Trim ring for flush mounting of fixture in concrete pad or paving. Brass ring clamps to housing with stainless steel screw. 2" (50.8 mm) 12" DIA. (304.8 mm) Grout Mask Cat. No. l GM10 TR10 Trim Ring Included Grout mask for fixture support during concrete pour. Gal vanized steel ring and rebar supports fixture when tied into paving rebar. 2" grout space provided for finishing up to fixture (see page 5). 16J" DIA. (412.8 mm) 2" (50.8 mm) 10L" (273.1 mm)

Page: 4 of 6 Optional Features Lens Accessories Cat. No. (See right) HL - Hex Cell Louver: Constructed of hex cell aluminum louvers with a cell dimension of J W x J D, producing a 45 cutoff angle, mounted in a circular frame, finished in baked high-heat flat black. Inserts behind lens into lens gasket. Not for use in combination with SL spread or PL prismatic lenses. Cat. No. l HL10 Hex Cell Louver PL - Prismatic Lens: Softens lamp distribution. Best with flood lamps. Inserts behind lens into lens gasket. Not for use in combination with HL10 Louver. Cat. No. l PL10 Prismatic Lens SL - Spread Lens: Creates an oval beam pattern. Best with spot lamps. Inserts behind lens into lens gasket. Not for use in combination with HL10 louver. Cat. No. l SL10 Spread Lens PL10 SL10 P S

Page: 5 of 6 Installation Recommendations Create a Buffer ZoneWhen fixtures are located in areas planted in ground cover or shrubbery, construct a buffer zone to prevent lens overgrowth and to create an edge for trimming. Elevate the fixtures for drainage and backfill with decorative rock. As the ground cover grows, the fixtures will look flush even though they are 2"to 4"above grade. Advantages Prevents lens overgrowth. Provides a defined edge for trimming. Provides drainage away from the lens to maintain light output. Visually looks like a flush installation. Buffer Zone Redwood or other material for edging. Rock fill 2" to 4" (50.8 mm to 101.6 mm) above grade. Install in Concrete For installations in ground cover, shrubbery or lawn areas, encase the fixture in concrete. This creates a buffer zone as described above, with the additional advantage of greater fixture stability. Elevate the fixture 2" to 4" above grade, and slope the concrete away from the lens ring for drainage. Advantages Cleaner, more stable installation, less susceptible to traffic and maintenance activity. Prevents lens overgrowth. Provides a defined edge for trimming. Provides drainage away from the lens to maintain light output. Visually looks like a flush installation. NOTE: Always use adequate rebar surrounding the fixture to prevent cracking of the concrete due to heat expansion. Concrete installation Concrete must have reinforcing rods to prevent cracking from fixture heat expansion. Rock fill 2" to 4" (50.8 mm to 101.6 mm) above grade. In Paved Areas When in-grade luminaires are installed in paving, it is usually required that the lens frame be flush with finished grade. To make this installation easier, Kim offers an optional grout mask (page 3) to support the fixture at the proper height during the concrete pour. The grout mask is normally tied into the paving rebar for support. Advantages Supports fixture at proper height during concrete pour. Provides 2" grout space for finishing. Easily adapts to any paving material; concrete, brick, stone, etc. Provides maximum driveover durability. NOTE: See safety and warranty information on page 6. Paved Area Installation Optional grout mask supports fixture during concrete pour. Tie grout mask to rebar for support. 2" (50.8 mm) grout space for finishing. Encase entire fixture in Concrete

Page: 6 of 6 Safety and Warranty Information- Safety and Maintenance Warning 1. Fixtures must be grounded in accordance with national, state, and/or local codes. Failure to do so may result in serious personal injury. 2. Extreme caution should be taken when fixtures are used in paved areas. High temperature lenses can burn feet, hands or objects inadvertently placed on top of fixtures. If fixtures must be used in paved areas, locate them away from normal pedestrian traffic, and use the lowest wattage lamp possible. 3. It is recommended that all conduit entries be sealed with RTV silicone to maintain a clean, dry splice compartment. 4. To maintain light efficiency and prevent fixture overheating, lenses must be kept clean and free of dirt, dust, leaves, and trash. 5. Lightvault fixtures are not approved for any submersible installations including fountains, ponds, reflecting ponds or swimming pools.* 25/7 Year Limited Warranty When installed according to Kim Installation Instructions and accepted trade practices, the solid bronze trim rings on LTV Series Kim products are warranted for 25 years, and the composite housings are warranted for 7 years, from date of sale, against manufacturing defects and failure due to corrosion. All other fixture components (excluding lamps) are warranted to be free of defects in material and workmanship for 1 year from date of sale. During the warranty periods, with proof of purchase, Kim will repair or replace with the same or similar product, at Kim s option, without charge. Labor costs are the owner s responsibility and are excluded from this warranty. This warranty is void if the product is modified, tampered with, misapplied, poorly installed, improperly maintained or subjected to abnormal conditions. Repair or replacement as provided under this warranty is the exclusive remedy of the purchaser. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of fitness for the particular application. Kim Lighting shall not be liable to the purchaser for indirect or consequential damages.