1 HIH-4000 Series Humidity Sensors DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users. Direct input to a controller or other device is made possible by this sensor s near linear voltage output. With a typical current draw of only 200 μa, the HIH-4000 Series is often ideally suited for low drain, battery operated systems. Tight sensor interchangeability reduces or eliminates OEM production calibration costs. Individual sensor calibration data is available. The HIH-4000 Series delivers instrumentation-quality RH (Relative Humidity) sensing performance in a competitively priced, solderable SIP (Single In-line Package). Available in two lead spacing configurations, the RH sensor is a laser trimmed, thermoset polymer capacitive sensing element with on-chip integrated signal conditioning. The sensing element's multilayer construction provides excellent resistance to most application hazards such as wetting, dust, dirt, oils and common environmental chemicals. FEATURES Molded thermoset plastic housing Near linear voltage output vs % RH Laser trimmed interchangeability Low power design Enhanced accuracy Fast response time Stable, low drift performance Chemically resistant POTENTIAL APPLICATIONS Refrigeration equipment HVAC (Heating, Ventilation and Air Conditioning) equipment Medical equipment Drying Metrology Battery-powered systems OEM assemblies
2 HIH-4000 Series TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.) Parameter Minimum Typical Maximum Unit Specific Note Interchangeability (first order curve) 0% RH to 59% RH -5 5 % RH 60% RH to 100% RH -8 8 % RH Accuracy (best fit straight line) % RH 1 Hysterisis 3 % RH Repeatability ±0.5 % RH Settling time 70 ms Response time (1/e in slow moving air) 15 s Stability (at 50% RH) 1.2 % RH Voltage supply Vdc 2 Current supply μa Voltage output (1 st order curve fit) V OUT =(V SUPPLY )(0.0062(sensor RH) ), typical at 25 ºC Temperature compensation True RH = (Sensor RH)/( T), T in ºC Output voltage temperature, coefficient at -4 mv/ºc 50% RH, 5 V Operating temperature -40[-40] See Figure 1. 85[185] ºC[ºF] Operating humidity 0 See Figure % RH 3 Storage temperature -50[-58] 125[257] ºC[ºF] Storage humidity See Figure 2. % RH 3 Specific Notes: 1. Can only be achieved with the supplied slope and offset. For HIH and HIH catalog listings only. 2. Device is calibrated at 5 Vdc and 25 ºC. 3. Non-condensing environment. FACTORY CALIBRATION DATA HIH-4000 Sensors may be ordered with a calibration and data printout. See Table 2 and the order guide on the back page. TABLE 2. EXAMPLE DATA PRINTOUT Model HIH Channel 92 Wafer M MRP Calculated values at 5 V V OUT at 0% RH V OUT at 75.3% RH Linear output for 3.5% RH accuracy at 25 C Zero offset Slope RH V V V mv/%rh (V OUT - zero offset)/slope (V OUT )/ Ratiometric response for 0% RH to 100% RH V OUT V SUPPLY ( to ) General Notes: Sensor is ratiometric to supply voltage. Extended exposure to >90% RH causes a reversible shift of 3% RH. Sensor is light sensitive. For best performance, shield sensor from bright light. 2
3 Humidity Sensors FIGURE 1. OPERATING ENVIRONMENT (Non-condensing environment.) Relative Humidity FIGURE 2. STORAGE ENVIRONMENT (Non-condensing environment.) 100% 90% 80% Relative Humidity 70% 60% 50% 40% 30% 20% 10% 0% Recommended storage zone Temperature ºC Honeywell Sensing and Control 3
4 HIH-4000 Series FIGURE 3. TYPICAL OUTPUT VOLTAGE VS RELATIVE HUMIDITY (At 25 ºC and 5 V.) Output Voltage (Vdc) Sensor Response Sensor Response Best Linear Fit Relative Humidity (%RH) FIGURE 4. TYPICAL OUTPUT VOLTAGE (BFSL) VS RELATIVE HUMIDITY (At 0 ºC, 70 ºC and 5 V.) Output Voltage (Vdc) C 70 C Relative Humidity (%) 4
5 Humidity Sensors FIGURE 5. HIH-4000 SERIES MOUNTING DIMENSIONS (For reference only. mm/[in]) HIH HIH HIH HIH HIH ,17 [0.164] 4,17 [0.164] 2,03 [0.080] 8,59 [0.338] 1,91 [0.075] 8,59 [0.338] 12,70 MIN. [0.50] 12,2 MIN. [0.48] -ve +ve -ve +ve OUT 1,27 [0.050] 3X 0,38 [0.015] 2,54 [0.100] OUT 2,54 ±0,72 [0.10 ±0.03] 5,08 REF. [0.20] 3X 0,38 [0.015] 2,54 ±0,72 [0.10 ±0.03] Honeywell Sensing and Control 5
6 HIH-4000 Series FIGURE 6. TYPICAL APPLICATION CIRCUIT ORDER GUIDE Catalog Listing HIH HIH HIH HIH HIH Description Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP Integrated circuit humidity sensor, 2,54 mm [0.100 in] lead pitch SIP, calibration and data printout Integrated circuit humidity sensor, 1,27 mm [0.050 in] lead pitch SIP, calibration and data printout Equivalent to HIH FURTHER HUMIDITY SENSOR INFORMATION See the following associated literature at Product installation instructions Application sheets: Humidity Sensor Performance Characteristics Humidity Sensor Theory and Behavior Humidity Sensor Moisture and Psychrometrics Thermoset Polymer-based Capacitive Sensors 6
7 Humidity Sensors THIS PAGE INTENTIONALLY LEFT BLANK. Honeywell Sensing and Control 7
8 WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: [email protected] Internet: Phone and Fax: Asia Pacific Fax Europe +44 (0) (0) Fax Latin America Fax USA/Canada Fax Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN EN IL50 GLO Printed in USA May Honeywell International Inc. All rights reserved.
humidity sensors Line Guide FEATURES Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH7000 Series, HIH8000 Series
Humidity Sensors Line Guide Performance and reliability. At Honeywell Sensing and Productivity Solutions (S&PS), each sensor is designed to provide enhanced stability, reliability and sensitivity. Digital
FEATURES Temperature-compensated magnetics Miniature plastic package Low voltage: 3.8 V operation
DESCRIPTION The SS400F and SS400G Series sensors are small, versatile digital Hall-effect devices that are operated by the magnetic field from a permanent magnet or an electromagnet, and are designed to
Industrial VRS Magnetic Speed Sensors
Industrial VRS Magnetic Speed Sensors DESCRIPTION High Resolution VRS sensors are designed for use in applications where precise timing pulse is required, and/or fine pitch gears are used. Proper alignment
SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control
Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response
Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH8000 Series ±2.0 %RH Accuracy. Datasheet
Honeywell HumidIcon Digital Humidity/Temperature Sensors HIH8000 Series ±2.0 %RH Accuracy Datasheet Honeywell HumidIcon Digital Humidity/Temperature Sensors Honeywell HumidIcon Digital Humidity/Temperature
Airflow Sensors Line Guide
Airflow Sensors Line Guide Go with the flow of engineering leadership. All airflow sensors operate on heat transfer flow and differential pressure. But Honeywell Sensing and Control (S&C) offers advanced
Fiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
Honeywell Pressure Switches Line Guide
Honeywell Pressure Line Guide Better under pressure. For years, manufacturers and operators of heavy-duty equipment have trusted Honeywell pressure and vacuum switches. They re proven under pressure, in
Temp. & humidity Transmitter Instructions
Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity
Application Note Sensors and Flexible Heaters in Sleep Apnea Machines
Background Sleep apnea is the repeated cessation of breathing during sleep, sometimes hundreds of times during the night and often for a minute or longer. If left untreated, sleep apnea can cause high
Speed Sensors Line Guide
Speed Sensors Line Guide Speed and reliability. Honeywell S&PS offers electronic speed designed for enhanced reliability and an extended life. Honeywell uses multiple technologies to detect a change in
Model TJE. Precision Gage/Absolute Pressure Transducer DESCRIPTION FEATURES
Precision Gage/Absolute Transducer DESCRIPTION Model TJE pressure transducers are all-welded stainless steel sensors built for rugged industrial applications that require high accuracy and measurement
HM1500LF Relative Humidity Module
Small size product Product free from Lead, Cr(6+), Cd and Hg Humidity calibrated within +/-2% @55%RH Typical 1 to 3.6 Volt DC output for 0 to 100% RH at 5Vdc supply Ratiometric to voltage supply from 4.75Vdc
SEMICONDUCTOR TECHNICAL DATA
SEMICONDUCTOR TECHNICAL DATA Order this document by MPX5050/D The MPX5050 series piezoresistive transducer is a state of the art monolithic silicon pressure sensor designed for a wide range of applications,
HTM2500LF Temperature and Relative Humidity Module
Hermetic Housing Humidity calibrated within +/-2% @55%RH Temperature measurement through NTC 10kOhms +/-1% direct output Small size product Typical 1 to 4 Volt DC output for 0 to 100%RH at 5Vdc DESCRIPTION
Temperature Humidity Meter
971 Temperature Humidity Meter Users Manual PN 2441047 September 2005 Rev.1, 5/06 2005-2006 Fluke Corporation, All rights reserved. Printed in Taiwan All product names are trademarks of their respective
Humidity Sensor. Model HU-224/225
Humidity Sensor Model HU-224/225 RoHS Ultra fast response cross-linked bulk polymer capacitive sensing element Proprietary hydrophobic and oleophobic eptfe filter to protect the sensing element from condensation,
Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration
Relative Humidity Measurement and Calibration The widest range of humidity products from a pioneer of RH sensor development The best in Relative Humidity technology to optimize your process Whether you
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
Laptop Power Adapter for home/office User Manual
Laptop Power Adapter for home/office User Manual Introduction Congratulations and thank you for purchasing the Laptop Power Adapter for home/office from Belkin. This new Adapter provides a single source
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
6DF Series 6 Degrees of Freedom Inertial Measurement Unit, 6-D Motion Variant
6DF Series 6 Degrees of Freedom Inertial Measurement Unit, 6-D Motion Variant DESCRIPTION The Honeywell 6-D Motion Variant 6DF (six degrees of freedom) Inertial Measurement Unit (IMU) sensors are designed
Medical Applications SENSING AND CONTROL. Sensor and Switch Solutions
Medical Applications SENSING AND CONTROL Sensor and Switch Solutions Medical Application Lives can be on the line. So your switch and sensor technology should be exceptional all down the line. That s why
Ultrasonic Distance Meter. Operation Manual
XPROTEC Ultrasonic Distance Meter Operation Manual About XProTec Pro-Installer Tools The XProTec line from XFTP is a comprehensive lineup of professionalgrade technical tools. These full-featured, field-proven,
AAV003-10E Current Sensor
Datasheet AAV003-10E Current Sensor Key Features For Low Current Detection On-Chip Current Strap for Precise Operation 80 ma to +80 ma Linear Range Sensitivity up to 2 mv/ma AC or DC Measurement Ultraminiature
Contents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
How To Use The Visifault Visual Fault Locator
VisiFault Visual Fault Locator Instruction Sheet The VisiFault Visual Fault Locator (VFL) is a visible light source that helps you trace optical fibers, check fiber continuity, and find faults such as
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-763 61-765 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
TC-9102 Series Surface Mount Temperature Controllers
TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented
User's Guide Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented Introduction Congratulations on your purchase of Extech's Laser Photo/Contact Tachometer with Non- Contact IR Thermometer,
NTMS4920NR2G. Power MOSFET 30 V, 17 A, N Channel, SO 8 Features
NTMS9N Power MOSFET 3 V, 7 A, N Channel, SO Features Low R DS(on) to Minimize Conduction Losses Low Capacitance to Minimize Driver Losses Optimized Gate Charge to Minimize Switching Losses These Devices
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Threaded Inline Air Heaters
Threaded Inline Air Heaters FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Safety SHOCK HAZARD! Only qualified individuals should install this heater and related controls. Follow
Data Sheet PS1B Pressure Switch
Data Sheet PS1B Pressure Switch Main Features Pressure Ranges 0 to 6 up to 0 to 600 bar (gage) Electrical Connection G 1/4 A DIN 3852-E or -A Pressure Connection Output Signal M12-4 Pin 4-20 ma, Programmable
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
Sip/Puff Switch User Guide
Sip/Puff Switch User Guide www.orin.com Table of Contents Table of Contents... 2 Legal Notices... 3 Declaration of Conformity with European Directives... 3 Application Disclaimer... 4 Introduction... 5
Model SRMD Setra Remote Monitoring Display
Model SRMD Setra Remote Monitoring Display 1.0 GENERAL INFORMATION Thank you for purchasing the Setra Remote Monitoring Display (SRMD). The SRMD is a digital panel meter with a bright 1 LED display for
Leak Detection System
Instructions - Parts List Leak Detection System 311200A For detecting leaks in your diaphragm pump system. Not for use in explosive atmospheres. Part No. 234576 120 psi (0.8 MPa, 8 bar) Maximum Air Input
User's Manual. Research Isometric Transducer 0 to 5 grams and 0 to 50 grams
Research Isometric Transducer 0 to 5 grams and 0 to 50 grams User's Manual Research Isometric Transducer 0 to 5 g and 0 to 50 g, 110 VAC/60 Hz MA1 72-4481 Research Isometric Transducer 0 to 5 g and 0 to
62 Max/62 Max + Infrared Thermometer
Infrared Thermometer Introduction The Fluke 62 MAX and 62 MAX + Infrared Thermometers (the Product) can determine the surface temperature by measurement of the infrared energy radiated from the target
DM Series CONTENTS. 1. Features 3. 2. Applications 3. 3. General 4. 4. Calibration 5. 5. Dimensions 6. 6. Specifications 7. 7. Calibration procedure 7
DM Series CONTENTS 1. Features 3 2. Applications 3 3. General 4 4. Calibration 5 DM-509-(M/T/S)X-(01/02) & DM-509-(H3/H5)-(01/02) 5. Dimensions 6 6. Specifications 7 7. Calibration procedure 7 The DM Series
Freescale Semiconductor. Integrated Silicon Pressure Sensor. On-Chip Signal Conditioned, Temperature Compensated and Calibrated MPX4080D.
Freescale Semiconductor Integrated Silicon Pressure Sensor + On-Chip Signal Conditioned, Temperature Compensated and Calibrated The series piezoresistive transducer is a state-of-the-art monolithic silicon
In-Line Filters and Coalescers with Automatic Drains
Instructions/Parts In-Line Filters and Coalescers with Automatic Drains 310611G EN Air Filter with Automatic Drain Part No. 22601, Series B Maintenance To maintain maximum filtering efficiency and to avoid
MEDION LIMITED WARRANTY Medion warrants that the product accompanied by this limited warranty is free from manufacturing defects in material or workmanship for a period of 12 months from the date of original
NUD4011. Low Current LED Driver
NUD0 Low LED Driver This device is designed to replace discrete solutions for driving LEDs in AC/DC high voltage applications (up to 00 V). An external resistor allows the circuit designer to set the drive
Fabric Sensor Evaluation Kit Information Sheet
Smart, soft, stretchable sensors Fabric Sensor Evaluation Kit 2012 2015. Fabric Sensor Evaluation Kit Our fabric stretch sensor is tough, rugged, and can be sewn into garments. Its resilience to tearing
SKY13370-374LF: 0.5 to 6.0 GHz SPDT Switch, 50 Ω Terminated
DATA SHEET SKY13370-374LF: 0.5 to 6.0 GHz SPDT Switch, 50 Ω Terminated Applications WiMAX 802.16 RF1 RF2 Dual-band WLANs (802.11 a/b/g/n) LTE/4G systems 50 Ω 50 Ω Features 50 Ω matched RF ports in all
Medical Applications. sensing and control. Thermal Management Solutions
Medical Applications sensing and control Thermal Management Solutions Honeywell. Turning Challenges into Solutions. The Honeywell name stands for dependability, a critical trait for products used in medical
APG. PT-400 Heavy Duty, Amplified Output Pressure Transducer
PT-400 Heavy Duty, Amplified Output Pressure Transducer C US The PT-400 offers high accuracy and reliability over a wide range of pressures. The small size, integrated electronics, wide operating temperature
Heavy Duty Pressure Sensors/ Transducers Line Guide
Sensors/ Line Guide products. Built for the toughest applications. Honeywell Sensing and Productivity Solutions (S&PS) offers decades of experience in the heavy duty pressure products industry. That s
CLEARSENSE - H 2 S Direct-Read Dosimeter For passive monitoring of hydrogen sulfide (H 2 S)
Bringing Science to the Surface TM CLEARSENSE - H 2 S Direct-Read Dosimeter For passive monitoring of hydrogen sulfide (H 2 S) Product No.: CS-H2S-B5 & CS-PV-H2S & CS-DR-300 Important: Read instructions
Models SFP33 & SFP32 Pressure Transmitters
SFP33 Flow-Through Pressure Transmitter SFP32 Single-Ended Pressure Transmitter DS-PR-SFP-eng April, 2016 Data Sheet Models SFP33 & SFP32 Pressure Transmitters Pressure Brooks Seal Free Pressure Measurement
Installation Guide Smart-UPS X External Battery Pack SMX120BP
Installation Guide Smart-UPS X External Battery Pack SMX120BP Inventory Inspect the contents upon receipt. Notify the carrier and dealer if there is damage. Two bezels Tie brackets used to secure multiple
Manual. Solar Fountain Mobile Phone Charger
EN Manual Solar Fountain Mobile Phone Charger Copyrights 2008 Victron Energy B.V. All Rights Reserved This publication or parts thereof may not be reproduced in any form, by any method, for any purpose.
6 & 12 Volt Battery and Systems Tester with 100 Amp Load
6 & 12 Volt Battery and Systems Tester with 100 Amp Load Form No. 841-731 -000 DESCRIPTION This Load Tester tests 6 or 12 volt automotive-size lead-acid batteries under load. It will also test 6 or 12
AAT3520/2/4 MicroPower Microprocessor Reset Circuit
General Description Features PowerManager The AAT3520 series of PowerManager products is part of AnalogicTech's Total Power Management IC (TPMIC ) product family. These microprocessor reset circuits are
OLF500: High CMR, High-Speed Logic Gate Hermetic Surface Mount Optocoupler
TM DATA SHEET OLF500: High CMR, High-Speed Logic Gate Hermetic Surface Mount Optocoupler Features Hermetic SMT flat-pack package Electrical parameters guaranteed over 55 C to +125 C ambient temperature
INSTRUCTION MANUAL MODEL PCD-88
INSTRUCTION MANUAL MODEL PCD-88 CLOSED CAPTION DECODER LINK ELECTRONICS, INC. 2137 Rust Avenue Cape Girardeau, Missouri 63703 Phone: 573-334-4433 Fax: 573-334-9255 e-mail: sales @ linkelectronics.com website:
LM134-LM234-LM334. Three terminal adjustable current sources. Features. Description
Three terminal adjustable current sources Features Operates from 1V to 40V 0.02%/V current regulation Programmable from 1µA to 10mA ±3% initial accuracy Description The LM134/LM234/LM334 are 3-terminal
SMD Aluminum Solid Capacitors with Conductive Polymer
SMD Aluminum Solid Capacitors with Conductive Polymer FEATURES New OS-CON series provides improved characteristics with up to 25 C temperature capability and 35 V maximum voltage rating in a SMD package
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
Load Cell Amplifier Module. Instruction Manual LCA210-000
Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4
MPXAZ6115A MPXHZ6115A SERIES. Freescale Semiconductor Technical Data. MPXAZ6115A Rev 4, 01/2007
Freescale Semiconductor Technical Data Media Resistant and High Temperature Accuracy Integrated Silicon Pressure Sensor for Measuring Absolute Pressure, On-Chip Signal Conditioned, Temperature Compensated
Photodiode/Phototransistor Application Circuit < E V3 I P I V OUT E V2. Figure 1. Fundamental Circuit of Photodiode (Without Bias)
Application Note Photodiode/Phototransistor Application Circuit FUNDAMENTAL PHOTODIODE CIRCUITS Figures 1 and 2 show the fundamental photodiode circuits. The circuit shown in Figure 1 transforms a photocurrent
NFC Communication Tray Model: HHX-IT3-Z
INSTRUCTION MANUAL NFC Communication Tray Model: HHX-IT3-Z ENGLISH CONTENTS Introduction...3 Important safety information...4 Know your unit...6 Transferring data to the PC...7 Care and maintenance...8
RGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:
PR100/PR300/PR500 Pressure Logger Operation Contents: Product Applications and Useful Features Product Specifications Operating Instructions / Getting Started DicksonWare Software Specifications Product
Pressure transmitter For general industrial applications Model A-10
Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 for further approvals see page 9 Applications Machine building Shipbuilding
Battery Charger. Instruction Manual 309502G
Instruction Manual Battery Charger 309502G EN Part No. 117427, Single Bay Charger, Series B, North America (N.A.) Part No. 120110, Single Bay Charger, Series B, Australia Part No. 117429, Four Bay Charger,
INSTRUCTION MANUAL DTH31. 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: [email protected]
INSTRUCTION MANUAL DTH31 Digital Psychrometer 1-800-547-5740 Fax: (503) 643-6322 www.ueitest.com email: [email protected] Introduction The DTH31 Digital Psychrometer is an advanced handheld humidity and
Rosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
TPN4R712MD TPN4R712MD. 1. Applications. 2. Features. 3. Packaging and Internal Circuit. 2014-12 2015-04-21 Rev.4.0. Silicon P-Channel MOS (U-MOS )
MOSFETs Silicon P-Channel MOS (U-MOS) TPN4R712MD TPN4R712MD 1. Applications Lithium-Ion Secondary Batteries Power Management Switches 2. Features (1) Low drain-source on-resistance: R DS(ON) = 3.8 mω (typ.)
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
CL90i. 77-021 Please read these instructions before operating the product. 3 - Beam Self-Leveling Cross Line Laser
3 - Beam Self-Leveling Cross Line Laser CL90i 77-01 Please read these instructions before operating the product Self-Leveling GB D F I E PT NL DK SE FIN NO PL GR CZ RU HU SK SI BG RO EE LV LT Contents
S112-XHS. Description. Features. Agency Approvals. Applications. Absolute Maximum Ratings. Schematic Diagram. Ordering Information
Description Features The S112-X is a bi-directional, single-pole, single-throw, normally open multipurpose solid-state relay. The circuit is composed of one input IR LED with a series limiting resistor
BroadBand PowerShield. User Manual
BroadBand PowerShield User Manual 990-0375G 12/2006 Chapter 1 General Information The PowerShield provides a power source for broadband telephony and other DC applications. Safety This Safety Guide contains
User's Manual. Heavy Duty Dissolved Oxygen Meter Model 407510
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions
Mounting and operating instructions CONTOIL DFM 8EDM Table of contents Safety instructions 2 - Designed use - Installation, commissioning and operation - Operational safety - Return of the instruments
NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
NUD4001, NSVD4001. High Current LED Driver
NUD, NSVD High Current LED Driver This device is designed to replace discrete solutions for driving LEDs in low voltage AC DC applications. V, V or V. An external resistor allows the circuit designer to
Ride-on Car OWNER S MANUAL KT1151TG. Keep instructions for future reference
Audi TT Ride-on Car KT1151TG OWNER S MANUAL Keep instructions for future reference 1 Safety The owner s manual contains assembly, use and maintenance instructions. The vehicle must be assembled by an adult
Signal Manager Installation and Operation Manual
Signal Manager Installation and Operation Manual Rev.11/28/2008 Part # 26550007 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 3 FUNCTION AND THEORY... 3 CHAPTER 2: SYSTEM INSTALLATION... 4 HARDWARE
User's Manual. Model 461995 Laser Photo / Contact Tachometer. Introduction
User's Manual Model 461995 Laser Photo / Contact Tachometer Laser Photo/ Contact Tachometer 461995 MEMORY rpm PHOTO CONTACT ft/min m/min Introduction Congratulations on your purchase of Extech's Laser
2N6387, 2N6388. Plastic Medium-Power Silicon Transistors DARLINGTON NPN SILICON POWER TRANSISTORS 8 AND 10 AMPERES 65 WATTS, 60-80 VOLTS
2N6388 is a Preferred Device Plastic MediumPower Silicon Transistors These devices are designed for generalpurpose amplifier and lowspeed switching applications. Features High DC Current Gain h FE = 2500
QFP910. Water detector. Building Technologies. CE1N2732en. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060
DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL 854060 (FOR DUSTTRAK II AND DRX AEROSOL MONITOR MODELS 8540 AND 8543) OPERATION AND MAINTENANCE MANUAL P/N 6008416, REVISION A MAY 2015 Copyright TSI Incorporated
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC
Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC BAYweb Remote Model BW-BCU5 Owner's Manual Copyright 2009-2010 Bay Controls, LLC Part Number: BW-BCU5DOC Revision: 0.2 April 18, 2010 BAYweb is a
SSM3K335R SSM3K335R. 1. Applications. 2. Features. 3. Packaging and Pin Configuration. 2012-07-19 Rev.3.0. Silicon N-Channel MOS (U-MOS -H)
MOSFETs Silicon N-Channel MOS (U-MOS-H) SSM3K335R SSM3K335R 1. Applications Power Management Switches DC-DC Converters 2. Features (1) 4.5-V gate drive voltage. (2) Low drain-source on-resistance : R DS(ON)
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
Model 43. Precision Low Profile Load Cell DESCRIPTION FEATURES
Precision Low Profile Load Cell DESCRIPTION Model 43 is a low profile pancake type load cells. These bonded foil, strain gage load cells are engineered to measure loads from 5 lb to 500,000 lb. The compression-only
WATERBUG@ INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007
WATERBUG@ INSTALLATION / OWNERS MANUAL MODEL WB-200 PN # D-01 l-0007 REV B INTRODUCTION Thank you for your purchase of the Winland WaterBug@ mode I WB-200. The WaterBug@ is completely electronic and is