Uses of Derivative Spectroscopy



Similar documents
Fundamentals of modern UV-visible spectroscopy. Presentation Materials

FTIR Instrumentation

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Copyright by Mark Brandt, Ph.D. 12

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Signal to Noise Instrumental Excel Assignment

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

The Measurement of Sensitivity in Fluorescence Spectroscopy

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.

Ultraviolet-Visible (UV-Vis) Spectroscopy Background Information

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

The accurate calibration of all detectors is crucial for the subsequent data

Using the Spectrophotometer

Making OSNR Measurements In a Modulated DWDM Signal Environment

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Introduction to Fourier Transform Infrared Spectrometry

The front end of the receiver performs the frequency translation, channel selection and amplification of the signal.

Upon completion of this lab, the student will be able to:

Electronic Communications Committee (ECC) within the European Conference of Postal and Telecommunications Administrations (CEPT)

Module 13 : Measurements on Fiber Optic Systems

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Fiber Optic Sampling by UV/Vis and UV/Vis/NIR Spectroscopy

INTRODUCTION. The principles of which are to:

Supporting Information

2.02 DETERMINATION OF THE FORMULA OF A COMPLEX BY SPECTROPHOTOMETRY

AMINO ACID ANALYSIS By High Performance Capillary Electrophoresis

5 Numerical Differentiation

Experiment #5: Qualitative Absorption Spectroscopy

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

UV-Visible Spectroscopy

Agilent Cary 4000/5000/6000i Series UV-Vis-NIR

Guidance for Industry

Blue Laser Technology Applied to the Microtrac Unified Scatter Technique for Full- Range Particle Size Measurement.

5.33 Lecture Notes: Introduction to Spectroscopy

2 Spectrophotometry and the Analysis of Riboflavin

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Spectrophotometric Determination of the pka of Bromothymol Blue

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

Characterizing Digital Cameras with the Photon Transfer Curve

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Function Guide for the Fourier Transformation Package SPIRE-UOL-DOC

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

High-Concentration Submicron Particle Size Distribution by Dynamic Light Scattering

A Beer s Law Experiment

ANALYSIS OF ASPIRIN INFRARED (IR) SPECTROSCOPY AND MELTING POINT DETERMINATION

Sampling Theorem Notes. Recall: That a time sampled signal is like taking a snap shot or picture of signal periodically.

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Maximizing Receiver Dynamic Range for Spectrum Monitoring

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

where h = J s

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

Extraction Heights for STIS Echelle Spectra

Chapter 5 -- The Spectrophotometric Determination of the ph of a Buffer. NAME: Lab Section: Date: Sign-Off:

MATRIX TECHNICAL NOTES

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Making Accurate Voltage Noise and Current Noise Measurements on Operational Amplifiers Down to 0.1Hz

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

Improving Chromatic Dispersion and PMD Measurement Accuracy

Lab #11: Determination of a Chemical Equilibrium Constant

Reaction of Blue Food Dye with Bleach

VWR SPECTROPHOTOMETERS

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Transmission Lines. Smith Chart

Molecular Spectroscopy

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

Jeff Thomas Tom Holmes Terri Hightower. Learn RF Spectrum Analysis Basics

COLORIMETER. Description 0358BT. Figure 1. The Colorimeter

Scanners and How to Use Them

Ultraviolet Spectroscopy

Fiber Optics: Fiber Basics

DYNAMIC LIGHT SCATTERING COMMON TERMS DEFINED

TCOM 370 NOTES 99-4 BANDWIDTH, FREQUENCY RESPONSE, AND CAPACITY OF COMMUNICATION LINKS

7. DYNAMIC LIGHT SCATTERING 7.1 First order temporal autocorrelation function.

Raman Spectroscopy Basics

PHYS 331: Junior Physics Laboratory I Notes on Noise Reduction

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F)

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Fraunhofer Diffraction

Signal, Noise, and Detection Limits in Mass Spectrometry

NRZ Bandwidth - HF Cutoff vs. SNR

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Measuring Protein Concentration through Absorption Spectrophotometry

Application Note: Absorbance

INTERNATIONAL OLIVE COUNCIL

HD Radio FM Transmission System Specifications Rev. F August 24, 2011

Optimizing IP3 and ACPR Measurements

Introduction to Receivers

Elasticity. I. What is Elasticity?

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

AVR127: Understanding ADC Parameters. Introduction. Features. Atmel 8-bit and 32-bit Microcontrollers APPLICATION NOTE

Transcription:

Uses of Derivative Spectroscopy Application Note UV-Visible Spectroscopy Anthony J. Owen Derivative spectroscopy uses first or higher derivatives of absorbance with respect to wavelength for qualitative analysis and for quantification. The concept of derivatizing spectral data was first introduced in the 1950s, when it was shown to have many advantages. However, the technique received little attention primarily because of the complexity of generating derivative spectra using early UV-Visible spectrophotometers. The introduction of microcomputers in the late 1970s made it generally practicable to use mathematical methods to generate derivative spectra quickly, easily and reproducibly. This significantly increased the use of the derivative technique. In this application note we review briefly the mathematics and generation methods of derivative spectroscopy. We illustrate the features and applications using computer-generated examples. Agilent Technologies Innovating the HP Way

Introduction If a spectrum is expressed as absorbance, A, as a function of wavelength, l, the derivative spectra are: Zero order First order A f( λ) da f ( λ) dλ 1 0 300 700 300 700 2.0E-04 E+00-2.0E-04 Second order 2 da 2 f ( λ) dλ -1-4.0E-04 1st derivative -6.0E-04 2nd derivative 300 700 300 700 2.0E-04 3rd derivative E+06 4rd derivative Figure 1 shows a computer simulation of the effects of derivatization on the appearance of a simple Gaussian absorbance band. Derivative spectra are always more complex than zeroorder spectra. E-04 E+00 -E-04-2.0E-04 5.0E-07 E+00-5.0E-07 300 700 300 700 Figure 1 and derivative spectra of a Gaussian band A first-order derivative is the rate of change of absorbance with respect to wavelength. A firstorder derivative starts and finishes at zero. It also passes through zero at the same wavelength as l max of the absorbance band. Either side of this point are positive and negative bands with maximum and minimum at the same wavelengths as the inflection points in the absorbance band. This bipolar function is characteristic of all odd-order derivatives. The most characteristic feature of a second-order derivative is a negative band with minimum at the same wavelength as the maximum on the zero-order band. It also shows two additional positive satellite bands either side of the main band. A fourth-order derivative shows a positive band. A strong negative or positive band with minimum or maximum at the same wavelength as l max of the absorbance band is characteristic of the even-order derivatives. Note that the number of bands observed is equal to the derivative order plus one.

Quantification If we assume that the zero-order spectrum obeys Beer s law, there is a similar linear relationship between concentration and amplitude for all orders of derivative: Zero order First order n th order l A e b c Aεb c da dε dλ dλ bc n n d A d ε d d bc n n λ λ wavelength absorbance extinction coefficient sample path length sample concentration For single component quantification the selection of wavelengths for derivative spectra is not as simple as for absorbance spectra because there are both positive and negative peaks. For the evenorder derivatives there is a peak maximum or minimum at the same l max as the absorbance spectrum but for the odd-order derivatives this wavelength is a zero crossing point. Taking the difference between the highest maximum and the lowest minimum gives the best signal-tonoise ratio but may lead to increased sensitivity to interference from other components. Obtaining derivative spectra Derivative spectra can be obtained by optical, electronic, or mathematical methods. Optical and electronic techniques were used on early UV-Visible spectrophotometers but have largely been superseded by mathematical techniques. The advantages of the mathematical techniques are that derivative spectra may be easily calculated and recalculated with different parameters, and smoothing techniques may be used to improve the signal-to-noise ratio. Optical and electronic techniques The main optical technique is wavelength modulation, where the wavelength of incident light is rapidly modulated over a narrow wavelength range by an electromechanical device. The first and second derivatives may be generated using this technique. It is popular for dedicated spectrophotometer designs used in, for example, environmental monitoring. First-derivative spectra may also be generated by a dual wavelength spectrophotometer. The derivative spectrum is generated by scanning with each monochromator separated by a small constant wavelength difference. First and higher-order derivatives can be generated using analog resistance capacitance devices. These generate the derivative as a function of time as the spectrum is scanned at constant speed (da/dts). For the first derivative: da da dλ 1 S dt Higher-order derivatives are obtained by using successive derivators. The electronic method suffers from the disadvantage that the amplitude and wavelength shift of the derivatives varies with scan speed, slit width, and resistance-capacitance gain factor. Mathematical techniques To use mathematical techniques the spectrum is first digitized with a sampling interval of Dl. The size of Dl depends on the natural bandwidth (NBW) of the bands being processed and of the bandwidth of the instrument used to generate the data. Typically, for UV-Visible spectra, the NBW is in the range 10 to 50 nm. Firstderivative spectra may be calculated simply by taking the difference in absorbance between two closely spaced wavelengths for all wavelengths : D λ+ λ/ 2 ( Aλ+ λ Aλ) λ Where the derivative amplitude, D l, is calculated for a wavelength intermediate between the two absorbance wavelengths. For the second-derivative determination three closely-spaced wavelength values are used: D λ ( Aλ λ 2Aλ+ Aλ + λ) 2 λ Higher-order derivatives can be calculated from similar expressions. This method involves simple linear interpolation between adjacent wavelengths. A better method is that proposed by Savitzky and Golay. To calculate the derivative at a particular wavelength, l, a window of ±n data points is selected and a polynomial is fitted using the least squares method: l Aλ a0 + a1λ+ Κ + a l λ

Features and applications An advantage of this method is that it can be used to smooth the data. If the polynomial order, l, is less than the number of data points (2n+1) in the window, the polynomial generally cannot go through all data points and thus the least squares fit gives a smoothed approximation to the original data points. This feature can be used to counteract the degradation of signal-to-noise that is inherent in the derivatization process (see below). The coefficients a 0...a l at each wavelength multiplied by the factorial of the order are the derivative values: a 1 is the first derivative, 2xa 2 the second derivative, 6xa 3 the third derivative, and so on. Savitzky and Golay developed a very efficient method to perform the calculations and this is the basis of the derivatization algorithm in most commercial instruments. Other techniques for calculating derivatives, for example, using Fourier Transforms, are available but are not commercially popular. One consequence of these mathematical methods for the calculation of derivatives is that data points at the beginning and end of the wavelength range are lost. If three data points are used for the process then one data point will be lost at each end of the range for each derivative order. If five points are used then two points will be lost and so on. It should be clearly understood that, although transformation of a UV-Visible spectrum to its first or higher derivative usually yields a more complex profile than the zero-order spectrum (see below), the intrinsic information content is not increased. In fact, it is decreased by the loss of lowerorder data such as constant offset factors. For clarity the points made in the following discussion are illustrated using computer-generated examples. In the figures, dotted lines show the baseline, dashed lines show component spectra, and solid lines show the analyte spectrum made up from the component spectra. Graphics As shown in figure 1 there is an increase in the number of bands as higher orders of derivative are calculated. This increase in the complexity of the derivative spectra can be very useful in qualitative analysis, either for characterizing materials or for identification. Spectra that are very similar in absorbance mode may reveal significant differences in the derivative mode. 1.5 5.0E-06 E-06-5.0E-06 For example, the absorbance spectrum of the steroid testosterone has a single, broad, featureless band centered at about 330 nm but the second derivative has six quite distinctive peaks. Resolution As figure 1 shows, the derivative centroid bandwidth of the evenorder derivatives decreases with increasing order. Relative to the zero-order spectrum the derivative centroid bandwidth for a Gaussian band is observed to decrease to 53 %, 41 %, and 34 % of the original bandwidth in the second, fourth, and sixth orders respectively. This feature may be used in qualitative analysis to identify the presence of two analytes with very similar l max values that are not resolved in the absorbance spectrum. Figure 2 shows a computer simulation. Figure 2 Resolution enhancement

In absorbance mode, when two Gaussian bands with 40 nm NBW and separated by 30 nm, are added the result is a single band with a maximum midway between the two component bands. The two components are not resolved. In the fourth derivative the presence of these two bands is clearly visible with maxima centered close to the l max of the component bands. Although the bands have been resolved there is no indication of whether these arise from two chromophores in a single compound or in two different compounds. It is often claimed that this increased resolution and the increased differentiation between spectra in the derivative mode allows multicomponent analysis of mixtures of components with similar spectra that cannot be resolved in the absorbance mode. However, as noted above the information content of derivative spectra is, in fact, less than the absorbance spectra and it can easily be shown that the improvements in quantitative accuracy are the result of other effects as described below. Background elimination A common, unwanted effect in spectroscopy is baseline shift. This may arise either from instrument (lamp or detector instabilities) or sample handling (cuvette repositioning) effects. Because the first derivative of a constant absorbance offset is zero, using the firstderivative spectra always eliminates such baseline shifts and improves the accuracy of quantification. This is illustrated in figure 3 where a 0.1 A offset, that would cause a 10 % quantitative error for the analyte, is completely eliminated by the first derivative. Other background effects that are directly proportional to higher orders of wavelength with the general form: 1 n A a + a λ... + a n λ 0 1 can be eliminated by using higher orders of derivative but such spectral features with exactly this form are very uncommon so this effect has little practical use. 300 700 300 700 Figure 3 Background elimination

Discrimination Probably the most important effect of the derivative process is that broad bands are suppressed relative to sharp bands and this suppression increases with increasing derivative order. This arises from the fact that the amplitude, D n, of a Gaussian band in the n th derivative is inversely proportional to the original bandwidth, W, raised to the n th degree: D n 1 n W Scattering is inversely proportional to the fourth (Rayleigh, small particles) or second (Tyndall, larger particles) power of the wavelength. Because the relationship is inverse, the use of derivatives will not eliminate the scattering component from the spectrum as has been claimed in some publications. However, because the scattering component resembles a very broad absorbance, using derivatives discriminates against it and reduces its effect on quantification. Thus for two coincident bands of equal intensity but different bandwidth in the zero order, the n th derivative amplitude of the sharper band, X, is greater than that of the broader band, Y, by a factor that is dependent on the relative bandwidth and the derivative order: n n DX WY n n D W Y Figure 4 shows the effect of taking derivatives of two bands, one with 160 nm NBW and one with 40 nm NBW. In absorbance mode they have equal amplitude, in first derivative the narrower band has four times greater amplitude and in the second derivative it has sixteen times the amplitude. This property is used to improve the accuracy of quantification of a narrow band component in the presence of a broad band component and to reduce error caused by scattering. X 5-5 05 00-05 1st derivative 2nd derivative Scattering is a common problem in biological analyses resulting from the measurement of small particulates present in the sample. -10 Figure 4 Discrimination against broad bands

Figure 5 shows an absorbance band with 40 nm NBW and the same band in the presence of a scattering background. Without any correction, the amplitude at 500 nm is 920 A instead of A because of the scattering contribution. Quantification at this wavelength results in an error of 9.2 %. Using the first derivative the contribution from the scattering component is reduced such that, using peak maximum to minimum, the signal in the presence of scattering is 2992 instead of 3024, that is a quantification error of only -1.1 %. This ability to discriminate against scattering components is widely used in the analysis of biological fluids that contain a high level of particulates, and in pharmaceutical analyses where particulate excipients in tablets and capsules cause quantification errors. 1-1 Figure 5 Scatter elimination 300 300 400 400 500 600 700 500 600 700 Matrix suppression The analytical problem is often not simply scattering, baseline shift, or unwanted broad absorbing components. It is a combination of two or more of these that results in a broad absorbing background matrix. In qualitative analyses, derivatization often allows the detection and positive identification of trace levels of a component in the presence of a strongly absorbing matrix. This is illustrated in Figure 6. A trace, 1 A, of a 40 nm NBW component with l max at 500 nm was added to a synthetic matrix. The matrix comprised offset, second and fourth-order scatter, and 320 nm NBW components with l max at 300 and 600 nm. In absorbance mode the presence of this component is virtually undetectable. In secondorder derivative mode its presence is obvious. 6.0E-05 4.0E-05 2.0E-05 E+00-2.0E-05 Figure 6 Matrix supression 200 400 600 800

In quantitative analyses, derivatization improves the accuracy of quantification in the presence of interference caused by a broad absorbing component, matrix, or scattering. Thus in the example given above, quantification of the analyte in the absorbance mode without any correction results in an error of nearly 5000 % (absorbance of 02 A instead of 1 A). Using the baseline-to-valley signal of the second-order derivative the error is -2.1% (2.37 x 10-5 instead of 2.42 x 10-5 A/l 2 ). An example of discrimination against a broad absorbing matrix is the quantification of caffeine in soft drinks. Soft drinks generally contain a mixture of natural and synthetic products with added colorants, resulting in a broad featureless absorbance over a wide wavelength range. In absorbance mode, quantification of caffeine is inaccurate because of the matrix effect but good accuracy can often be achieved using the second-derivative spectra. Instrument considerations Virtually all current UV-Visible spectrophotometers generate derivative spectra by mathematical means so instrument considerations for generation of derivative spectra by optical and electronic techniques are not discussed. Instrument requirements for derivative spectroscopy are, in general, similar to those for conventional absorbance spectroscopy but wavelength reproducibility and signal-to-noise are of increased importance. The increased resolution of derivative spectra puts increased demands on the wavelength reproducibility of the spectrophotometer. Small wavelength errors can result in much larger signal errors in the derivative mode than in the absorbance mode. The negative effect of derivatization on signal-to-noise also puts increased demands on low noise characteristics of the spectrophotometer. It is an advantage in this case, if the spectrophotometer can scan and average multiple spectra before derivatization to improve further the signal-to-noise ratio. For the derivatization process it is important to be able to control the degree of smoothing that is applied in order to adapt to differing analytical problems. In the case of the Savitzky-Golay method this means being able to vary the order of polynomial and the number of data points used. Signal-to-noise ratio An unwanted effect of the derivatization process is that the signal-to-noise ratio decreases as higher orders of derivatives are used. This follows from the discrimination effect and the fact that noise always contains the sharpest features in the spectrum. Thus, if the spectral data used in the derivative calculation is at 2 nm intervals, the noise has a 2 nm bandwidth. If the analyte band has a bandwidth of 20 nm then the signal-to-noise ratio of the first derivative is ten times worse than the zero-order spectrum. The decrease in signal-to-noise ratio can be reduced by using the smoothing properties of the Savitzky-Golay polynomial smoothing technique but great care must be taken as too high a degree of smoothing distorts the derivative spectrum. Alternative techniques, such as using a reference wavelength or full spectrum multicomponent analysis with a scattering spectrum as standard, may often be used to achieve the same analytical goals but without the reduced signal-to-noise penalty. Anthony J. Owen is product manager at Agilent Technologies, Waldbronn, Germany. For the latest information and services visit our world wide web site: http://www.agilent.com/chem Copyright 1995 Agilent Technologies All Rights Reserved. Reproduction, adaptation or translation without prior written permission is prohibited, except as allowed under the copyright laws. Publication Number 5963-3940E Agilent Technologies Innovating the HP Way