Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation



Similar documents
Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

About the BitStorm 6051 POTS Splitter

Insulation Resistance Testing of Low Voltage Cables in the Field

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

Video Camera Installation Guide

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Customer Substation Manual 08/05/02

LIEBERT VNSA Installation Sheet

Medium Voltage Electrical Distribution

Canopy Surge. User Manual

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Schneider Automation Modbus Plus Network Installing Clustered Node Devices Version 2.0

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

TC Grounding and Bonding for Telecommunications Systems

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Multiple Meter Installation Amperes Per Position -Single Phase, Self-contained

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Hyperlinks are Inactive

RADIANT PLASMA 4700 Plasma Spark Generator

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

Radiant Temperature Sensor TY7321

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Keystone Network Isolator with ESD- and Lightning Protection

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Model 201 Wiegand Touchpad Reader Installation Guide

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

Redundancy Module QUINT-DIODE/40

Remote Power Panels with Breakers

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

Z-TRAUQ INC. Tel.: (450) Fax: (450)

I NTERFACE CABLE ADAPTER MODULE

Intersection Preassembled 19-inch Rack

Secondary Unit Substations

Chapter 9. Bonding and Grounding

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

Operation and Installation Manual

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

SECTION DRY-TYPE TRANSFORMERS

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Medium Voltage Terminations, 5 kv 46 kv

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

TrueAlarm Fire Alarm Systems

Installation instructions for mains wire-in protectors ESP D1, D1R, D1/LCD and D1R/LCD variants

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

TRANSFORMER FITTINGS & ACCESSORIES

Technical data UNIBLOCK UBSF

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

800 Communications Circuits

Owner s Manual. Model 1812 Classic Telephone Intercom Systems

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Step 1. Item 6. Item 1

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

IP PHONE SYSTEM. CooVox Series-U60 For Small and Medium Business. Quick Installation Guide.

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Grounding & Bonding Why it is done And How to Install Properly

EH-20 20m antenna. By VE3RGW

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

TABLE OF CONTENT

Thermistor motor protection

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

PXL-250: Network Wiring

12V Dimmable Driver EL-TMDRVR

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electrical Grounding. Appendix C

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Distribution Dry Type Transformers

RAY-MAX Integrated Solar Power Strip

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

AMPSEAL* Automotive Plug Connector and Header Assembly

16300 MEDIUM VOLTAGE DISTRIBUTION

RM4TG20 three-phase network control relay RM4-T - range V

SECTION 22 LIGHTNING PROTECTION SYSTEM

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

Please check with your local inspection authority for any additional requirements before installation.

ELECTRIC UTILITY SERVICE EQUIPMENT REQUIREMENTS COMMITTEE, EUSERC

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

S&C BankGuard PLUS Control

HM-W536 Install Guide

Network Standard Advice No. 1420C 9/6/2011

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Transcription:

Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B

Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning Arresters 18KVA, 10KVA 2 2.3 5 kv Spark Gap 2 3.0 PRODUCT FEATURES 2 4.0 INSTALLATION 2 4.1 Mounting Lightning Arrester 3 4.2 Station Ground Connection 3 4.3 Remote Ground Connection 3 General Information 4 5.0 PHYSICAL CHARACTERISTICS 5 5.1 Mechanical Configuration 5 5.2 Environmental Requirements 5 Page 1

1.0 Scope This document describes the technical specifications, technical requirements and installation instructions for the P30027 and P30038 SNC Lyte Lynx Lightning Arrester packages. It provides an understanding of the basic functions and features available with these units. 2.0 Product Overview 2.1 Intended Uses The purpose of the lightning arrester is to protect the metallic shield of the CO/Remote cable and the isolation devices during lightning or fault conditions. When the voltage reaches the level of the arrester s discharge rating, the voltage will find a path to station ground rather than damaging the cable or isolation devices. 2.2 18kV and 10kV Lightning Arresters SNC offers two models of Lyte Lynx Lightning Arresters. Since Lyte Lynx carries a continuous rating of 20kV, 60HZ, RMS as well as a 65kV impulse peak voltage, the 18kV model (P30027) is normally recommended. However, for installation where the dielectric condition of the incoming CO/Remote cable is questionable, the 10kV model (P30038) may be desired since GPR voltages rarely exceed 10kV, 60Hz, RMS maximum. 2.3 5kV Spark Gap This feature allows termination of cable pairs for isolation transformer center tap drainage to provide protection for Class A service pairs whenever the lightning/surge arrester discharges. 3.0 Product Features The P30027 and P30038 use a non-shattering, polymer lightning arrester installed in an insulated housing. Each has a continuous kv arrester rating with a discharge voltage rating substantially lower than the tested 65 kv BIL of the Lyte Lynx system. During a lightning strike, the voltage potential difference between the CO/Remote cable shield and station ground is limited to the breakdown or discharge voltage of the arrester so that both the entrance cable and isolation equipment are protected. Mounted inside a fiberglass enclosure with a clear plastic protective cover, the arrester is normally installed near the CO/Remote cable entrance into the Lyte Lynx card shelf typically either directly below or alongside the shelf. 4.0 Installation CAUTION: To provide personnel isolation from local ground, stand on a thick rubber mat and use other adequate insulation devices (rubber gloves) when working on the Lyte Lynx system. Page 2

CAUTION: The incoming telephone pair(s) should be contained in insulated conduit (PVC, etc.), or the pair(s) should be jacketed with sufficient insulation to withstand a voltage rise from ground fault potential and from fault induction voltage. CAUTION: Any metallic shielding on the incoming CO/Remote pair(s) must be isolated from substation grounds all the way from the network low voltage interface (300 volt peak GPR point per IEEE Standard 487) to the entry into the Lyte Lynx. The conductors must also be isolated. 4.1 Mounting Lightning Arrester Drill holes in the back of the Lightning Arrester enclosure and securely mount to a non-metallic wall or backboard (use the backboard that the Lyte Lynx card cage is mounted to if backboard is large enough). Depending upon the space available, this can be to the left (looking at the front of the card cage) or just below the card cage. The Lightning Arrester may be mounted upside down to fit the situation. See Figure 1 for an example of how the lightning arrester is installed. 4.2 Station Ground Connection Connect a #6 AWG wire from the bus bar connector lug at the bottom of the arrester enclosure to station ground. Keep this wire as short as possible. See Figures 1 and 3. 4.3 Remote Ground Connection At the point where the cable would be centered in the Lightning Arrester enclosure, carefully strip off 4 to 6 inches of the cable jacket to reveal the cable shield. Open the cable shield by removing the center 2 or 3 inches of the exposed metallic cable shield. Try to do this without disturbing the cable pairs. Slip the cable through the PVC fittings on each side of the upper part of the enclosure. Holes in the PVC fittings allow the use of tie wraps (included) to secure the cable to the enclosure. Connect the wire attached to one end of the arrester to the CO side of the cable shield with a cable shield Bullit Bond (provided). Keep this wire from the cable shield to the arrester as short as possible avoid a large loop. Connect the wire attached to the 5kV spark gap to the station side of the cable shield - or with a separate wire - connect it directly from the spark gap to the ground terminal of the card shelf. See Figure 1. Page 3

General Information The above installation scheme meets the recommended protection practice of IEEE Standard 487-2000 - remote ground outside the GPR zone of influence (300 volt GPR location) is accessible via a 5 kv spark gap located in the lightning surge arrester housing external to the card shelf. This installation scheme also provides for coordinated 65 kv BIL protection of both the isolation equipment (shelf and cards) and the dedicated entrance cable. The 5 kv gap coordinates drainage of surge voltage difference between the dedicated cable pairs and the shield should the power type surge arrester operate and equalize ground potential difference between station ground and remote ground via the cable shield. The isolation system is designed around the protection practice of IEEE Standard 487-1992. It is recommended that this configuration be used in any application environment where surges are possible. The BIL of the isolation system is assured and the dedicated cable receives similar BIL protection and insulation protection coordination between shield and cable conductors. Note: In some applications remote ground is directly needed for a circuit function such as for PBX ground start trunks (a less desirable trunk seizure configuration that is more prone to possible transient voltage and circuit noise problems than a loop start trunk). When a direct remote ground connection is required, a protection system application utilizing the 5kV spark gap must have the gap bypassed by one of the pairs to get central office ground directly accessible to the PBX card. This effectively disables the 5kV spark gap. Figure 2: 10KVA Lightning Arrester P30038 Page 4

Connect to Card Shelf Remote Ground Connect to CO Cable Shield Connect Station Ground to This Ground Lug Figure 3: Lightning Arrester Connections 5.0 Physical Characteristics 5.1 Mechanical Configuration Table 1: Physical Dimensions PART NUMBER HEIGHT WIDTH DEPTH P30027 14.20 (36 cm) 21.25 (54 cm) 7.10 (18 cm) P30038 11.00 (28 cm) 15.00 (38 cm) 5.30 (13.5 cm) 5.2 Environmental Requirements The Lyte Lynx Lightning Arrester system may be installed in an indoor or moderate outdoor environment and is guaranteed operable in temperatures ranging from 40ºC to 100ºC ( 40ºF to 212ºF) and under humidity conditions from 0 99% relative humidity non-condensing. Page 5

For further information or for technical support call 800-558-3325 or visit www.sncmfg.com SNC Manufacturing Co., Inc. 101 West Waukau Ave., Oshkosh, WI 54902-7299 800-558-3325 or 920-231-7370 FAX 920-231-1090 E-mail: telecom@sncmfg.com Website: www.sncmfg.com Page 6 TO330 Rev. B - 09/11