Fundamentals of Cone-Beam CT Imaging



Similar documents
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

How To Improve Your Ct Image Quality

Purchasing a cardiac CT scanner: What the radiologist needs to know

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Digital Mammography Update: Design and Characteristics of Current Systems

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

State-of-the-Art Technology in Cardiac CT

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Siemens Computed Tomography

Endoscopy & X-Ray Image Sensors Markets

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

Concepts for High-Resolution Low-Dose CT of the Breast

Quality Control of Full Field Digital Mammography Units

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

Physics testing of image detectors

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

Basics of Clinical X-Ray Computed Tomography

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

Digital panoramic X-ray for practical diagnostics

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

Experimental study of beam hardening artefacts in photon counting breast computed tomography

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Data. microcat +SPECT

DICOM Correction Item

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

Checklist for the Qualification of Digital Detector Array Systems

Atomic and Nuclear Physics Laboratory (Physics 4780)

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.

Acknowledgements. PMH, Toronto David Jaffray Doug Moseley Jeffrey Siewerdsen. Beaumont Hospital Di Yan Alvaro Martinez. Elekta Synergy Research Group

Using a flat-panel detector in high resolution cone beam CT for dental imaging

Page: 1 of 6 Page: 1 of 6

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.

The professional for your diagnostics.

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

Tom Wilson Product Marketing Manager Delivery Systems Varian Medical Systems International AG. CERN Accelerator School, May 2015

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Instruction Sheet

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

3D Accuitomo FPD XYZ Slice View Tomograph. Super-High Resolution Images of Region of Interest

Coating Thickness and Composition Analysis by Micro-EDXRF

IGRT. IGRT can increase the accuracy by locating the target volume before and during the treatment.

Dental Radiography Core Subject. Digital Radiography

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

DENTAL Cone beam 3D X-RAY SYSTEM with

High Quality Image Magnification using Cross-Scale Self-Similarity

Digital Breast Tomosynthesis QC Requirements

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

Modern Fluoroscopy Imaging Systems

ZEISS Axiocam 506 color Your Microscope Camera for Imaging of Large Sample Areas Fast, in True Color, and High Resolution

MEDICAL IMAGING 2nd Part Computed Tomography

Introduction to Medical Imaging. Lecture 11: Cone-Beam CT Theory. Introduction. Available cone-beam reconstruction methods: Our discussion:

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Chest CT protocols. Mannudeep K. Kalra, MD, DNB. Dianna D. Cody, PhD. Massachusetts General Hospital Harvard Medical School

ENGLISH. Planmeca ProMax 3D concept

Possibilities and Limits of Digital Industrial Radiology: - The new high contrast sensitivity technique - Examples and system theoretical analysis

Sistemas de reducción de dosis en CT para pediatría. Nuevos avances Ángela de Pinto Siemens CT Business Manager

First In Vivo Medical Images Using Photon- Counting, Real-Time GPU Reconstruction

AN INNOVATIVE & CUTTING-EDGE DIGITAL RADIOGRAPHY SYSTEM

Silicon Lab Bonn. Physikalisches Institut Universität Bonn. DEPFET Test System Test DESY

3/12/2014. Disclosures. Understanding IAC CT Accreditation. Outline. Learning Objectives. Who is the IAC?

Proton tracking for medical imaging and dosimetry

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Radiation Strip Thickness Measurement Systems

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Digital Fluoroscopic Imaging: Acquisition, Processing & Display

THE DOSIMETRIC EFFECTS OF

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

Industrial X-ray for Nondestructive Testing Unrestricted Siemens AG All rights reserved

UV-NIR LASER BEAM PROFILER

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

Evaluation of a metal artifact reduction algorithm in CT studies used for proton radiotherapy treatment planning

Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1

The disclaimer on page 1 is an integral part of this document. Copyright March 1, 2016 by AAPM. All rights reserved.

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT

Tracking Radiation Exposure From Medical Diagnostic Procedures: Siemens Perspectives

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

X-ray Tomography in Industrial Metrology

Transcription:

Fundamentals of Cone-Beam CT Imaging Marc Kachelrieß German Cancer Research Center (DKFZ) Heidelberg, Germany www.dkfz.de

Learning Objectives To understand the principles of volumetric image formation with flat detectors. To understand the difference between CBCT and MSCT. To learn about reconstruction techniques and image processing. To become acquainted with the important image quality parameters.

Terminology Cone-Beam CT The shape of the x-ray ensemble depends on the pre patient collimation and can be approximated by a cone if the detector is a circle (e.g. an image intensifier) a pyramid if the detector is a rectangle (e.g. a flat detector) a distorted pyramid if the detector is an arc (e.g. a clinical CT detector) Cone-beam CT = a CT with many detector rows? a CT equipped with flat detectors? a CT that requires a volumetric reconstruction! Flat detector = indirect converting, based on TFT (amorph. Si) or CMOS (cryst. Si) a detector of low aspect ratio (number of columns number of rows) Often used synonymously: CT = clinical CT = diagnostic CT = MSCT = multi slice CT CBCT = cone-beam CT = FDCT = flat detector CT (non diagnostic)

Clinical CT e.g. Definition Flash dual source spiral cone-beam CT scanner, Siemens Healthcare, Forchheim, Germany. 43 cm/s scan speed, 247 ms scan time, 70 ms temp. res., 0.89 msv dose Courtesy of Stephan Achenbach Image courtesy by Siemens Healthcare

Fixed C-Arm CT e.g. floor-mounted Artis Zeego or ceiling-mounted Artis Zee, Siemens Healthcare, Forchheim, Germany Image courtesy by Siemens Healthcare

Mobile C-Arm CT e.g. Vision FD Vario 3D, Ziehm Imaging GmbH, Nürnberg, Germany Image courtesy by Ziehm Imaging

Dental Volume Tomography (DVT) e.g. Orthophos XG 3D, Sirona Dental Systems GmbH, Bensheim, Germany Image courtesy by Sirona Dental

CBCT Guidance for Radiation Therapy e.g. TrueBeam, Varian Medical Systems, Palo Alto, CA, USA

Detector Technology Clinical CT Detector Flat Detector Absorption efficiency Afterglow Dynamic range Cross-talk Framerate Scatter grid

Clinical CT Detector Flat Detector Gd 2 O 2 S 7.44 g/cm 3 CsI 4.50 g/cm 3 Anti-scatter grids are aligned to the detector pixels Anti-scatter grids reject scattered radiation Detector pixels are of about 1.2 mm size Detector pixels are structured, reflective coating maximizes light usage and minimizes cross-talk Thick scintillators improve dose usage Gd 2 O 2 S is a high density scintillator with favourable decay times Individual electronics, fast read-out (5 khz) Very high dynamic range (10 7 ) can be realized Anti-scatter grids are not aligned to the detector pixels The benefit of anti-scatter grids is unclear Detector pixels are of about 0.2 mm size Detector pixels are unstructured, light scatters to neighboring pixels, significant cross-talk Thick scintillators decrease spatial resolution CsI grows columnar and suppresses light scatter to some extent Row-wise readout is rather slow (25 Hz) Low dynamic range (<10 3 ), long read-out paths

Dose Efficiency of Flat Detectors Clinical CT (120 kv) Flat Detector CT (120 kv) Micro CT (60 kv) Material Gd 2 O 2 S CsI CsI Density 7.44 g/cm 3 4.5 g/cm 3 4.5 g/cm 3 Thickness 1.4 mm 0.6 mm 0.3 mm Manufacturer Siemens Varian Hamamatsu Water Layer 0 cm 20 cm 40 cm 0 cm 20 cm 40 cm 0 cm 4 cm 8 cm Photons absorbed 98.6% 97.7% 96.7% 80.0% 69.8% 62.2% 85.3% 85.6% 85.8% Energy absorbed 94.5% 91.4% 88.7% 66.6% 55.4% 48.3% 67.1% 65.2% 64.2% Absorption values are relative to a detector of infinite thickness.

Dynamic Range in Flat Detectors Table taken from [Roos et al. Multiple gain ranging readout method to extend the dynamic range of amorphous silicon flat panel imagers, SPIE Medical Imaging Proc., vol. 5368, pp. 139-149, 2004]. Additional values were added, for convenience.

No overexposure Intended overexposure (factor 4)

focal spot focal spot FOM y FOM z x y y x z Detector: 1000 1000 to 4000 4000 elements, typically

Filtered Backprojection (FBP) 1. Filter projection data with the reconstruction kernel. 2. Backproject the filtered data into the image: Smooth Standard Reconstruction kernels balance between spatial resolution and image noise.

Feldkamp-Type Reconstruction Approximate Similar to 2D reconstruction: row-wise filtering of the rawdata followed by backprojection True 3D volumetric backprojection along the original ray direction volume ray 3D backprojection

z Cone-Beam Artifacts z z Cone-angle Γ = 6 Cone-angle Γ = 14 Cone-angle Γ = 28 Defrise phantom focus trajectory

Data and Image Processing

Uncorrected 20

With Geometric Calibration

With Detector Calibration

With Scatter and Beam Hardening Correction

Spatial Resolution Method 1 Method 2 Method 3

Image Noise 150 HU / 600 HU Air ROI: µ = -995 HU, σ = 31 HU Soft tissue ROI: µ = 148 HU, σ = 59 HU Iodine ROI: µ = 423 HU, σ = 62 HU

Dependencies of IQ and Dose Image quality is determined by spatial resolution and contrast resolution (image noise) Image noise σ decreases with the square-root of dose Dose increases with the fourth power of the spatial resolution for a given object and image noise Noise relative to the background (= 1/SNR) Fourth power of the spatial resolution

Always Relate SNR and CNR to Unit Dose! SNR and CNR are useless for comparisons if these are not taken at the same dose or if SNR and CNR are not normalized to unit dose. The terms SNRD and CNRD are used for SNR normalized to unit dose and CNR normalized to unit dose, respectively.

Clinical CT vs. Flat Detector CT 8 lp/cm 10 lp/cm Clinical CT, Standard Kernel Flat Detector CT, 2 2 Binning

Clinical CT vs. Flat Detector CT -115 HU -85 HU -190 HU -55 HU Clinical CT, Standard Kernel C = 0 HU, W = 700 HU Flat Detector CT, 2 2 Binning

Clinical CT vs. FD-CT Clinical CT FD-CT Clinical CT FD-CT With EBHC Standard C0W400 C0W800 C0W200 C0W800 Siemens Somatom Definition vs. Siemens Axiom Artis

Clinical vs. Flat Detector CT Clinical CT Flat Detector CT Spatial resolution 0.5 mm 0.2 mm Contrast 3 HU 30 HU Dynamic range 20 bit 10 bit Dose efficiency 90% 50% Lowest rotation time 0.28 s 3 s Temporal resolution 0.07 s 3 s Frame rate 6000 fps 30 fps X-ray power 100 120 kw 5 25 kw

Summary Flat detector CT image reconstruction is typically based on the Feldkamp filtered backprojection algorithm. Apart from a higher spatial resolution, flat detectorbased cone-beam CT image quality is inferior to clinical CT image quality. The high spatial resolution (100 to 200 µm) and the good form factor (small, light weight) of flat detectors justifies their existence for several highly important medical applications (see presentations of Dr. Grass and Dr. Horner)

Thank You! This study was supported by xxxxxxxxx. Parts of the reconstruction software were provided by RayConStruct GmbH, Nürnberg, Germany. marc.kachelriess@dkfz.de This presentation will soon be available at www.dkfz.de/ct.