HOW TO SIZE A PRESSURE REGULATOR



Similar documents
Valve Sizing. Te chnic al Bulletin. Flow Calculation Principles. Scope. Sizing Valves. Safe Product Selection.

BASIC UNDERSTANDING OF FLOW CALCULATIONS AND ESTIMATES MAKES SIZING VALVES SIMPLER

Certain specific properties of compressed gases make them highly useful in various research activities.

Regulator Options and Accessories

Sizing Pressure Regulators & Control Valves

T U R B I N E G A S M E T E R

CO MPa (abs) 20 C

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

CHEMISTRY GAS LAW S WORKSHEET

Translate chemical symbols and the chemical formulas of common substances to show the component parts of the substances including:

1301 Series High-Pressure Regulators

Pressure and Temperature Controls

Theory, Application, and Sizing of Air Valves

Air Eliminators and Combination Air Eliminators Strainers

THE HUMIDITY/MOISTURE HANDBOOK

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Temperature. Number of moles. Constant Terms. Pressure. Answers Additional Questions 12.1

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

PRESSURE REGULATOR SERIES R 4100 R 2100 R 5100 VIRTUAL CATALOGUE FAIL TO OPEN REGULATOR BALANCED VALVE HIGH FLOW COEFFICIENT

FLUID FLOW Introduction General Description

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Fluid & Gas Properties

Facility Operations Physical Safety Guidance Document

Chapter 10. Flow Rate. Flow Rate. Flow Measurements. The velocity of the flow is described at any

CONTROL VALVE PRESSURE DROP AND SIZING

Chemical Calculations: Formula Masses, Moles, and Chemical Equations

Chapter 19 Purging Air from Piping and Vessels in Hydrocarbon Service

Unit 3 Notepack Chapter 7 Chemical Quantities Qualifier for Test

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Name Date Class STOICHIOMETRY. SECTION 12.1 THE ARITHMETIC OF EQUATIONS (pages )

C. starting positive displacement pumps with the discharge valve closed.

Water hammering in fire fighting installation

The Gas Laws. Our Atmosphere. Pressure = Units of Pressure. Barometer. Chapter 10

= 800 kg/m 3 (note that old units cancel out) J 1000 g = 4184 J/kg o C

1805 Series Relief Valves

Select the Right Relief Valve - Part 1 Saeid Rahimi

At the temperature of liquid hydrogen, however, 99.8% of the hydrogen molecules will be in the para form.

Fiscal Measurement Natural Gas

SIZING AND CAPACITIES OF GAS PIPING

Gas Custody Transfer Calibration

F321 MOLES. Example If 1 atom has a mass of x g 1 mole of atoms will have a mass of x g x 6.02 x = 7.

All Safe, Inc. Sherwood Master Distributor Toll Free: Fax:

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Stoichiometry. 1. The total number of moles represented by 20 grams of calcium carbonate is (1) 1; (2) 2; (3) 0.1; (4) 0.2.

Aeration Air & Digester Gas Flow Metering Using Thermal Mass Technology. HWEA 2011 Conference Craig S. Johnson

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

pressure inside the valve just before the final release of air. in pipeline systems resulting from 2p 1 p a m C D A o

The Fundamentals of Gas Flow Calibration

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

Element D Services Plumbing

VAL-MATIC VALVE AND MANUFACTURING CORP. 905 RIVERSIDE DRIVE, ELMHURST, IL TEL. (630) FAX.

Engineering Guide and Valve Selection Information

Dynamic Process Modeling. Process Dynamics and Control

1800C and 1800C-HC Series Service Regulators. Technical Bulletin

Appendix I: Cryogenic Reference Tables

Stoichiometry Exploring a Student-Friendly Method of Problem Solving

PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM

The Versatile Differential Pressure Transmitter. By David Gunn Honeywell Process Solutions

NITROUS TRANSFER PUMP INSTRUCTIONS

PIEZOMETER AIRFLOW MEASURING RING

Mechanical Seal Piping Plans

AS1 MOLES. oxygen molecules have the formula O 2 the relative mass will be 2 x 16 = 32 so the molar mass will be 32g mol -1

UNDERSTANDING REFRIGERANT TABLES

Chapter 17. For the most part, we have limited our consideration so COMPRESSIBLE FLOW. Objectives

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

Advanced Differential Pressure Flowmeter Technology V-CONE FLOW METER TECHNICAL BRIEF

atm = 760 torr = 760 mm Hg = kpa = psi. = atm. = atm. = 107 kpa 760 torr 1 atm 760 mm Hg = 790.

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

Physical and Chemical Properties of Matter

RITTER Multiple Sonic Nozzle Calibration System

PULSATION REDUCTION BY ACOUSTIC FILTERS FOR METERING APPLICATIONS. Robert J. McKee Ray G. Durke

289 Series Spring-Loaded Relief Valves

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

UCLA - Compressed Gas Cylinder Storage and Handling

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

Tadahiro Yasuda. Introduction. Overview of Criterion D200. Feature Article

Pump Formulas Imperial and SI Units

20.2 Chemical Equations

Compressor Performance

SIZING AND CAPACITIES OF GAS PIPING (Not Adopted by the State of Oregon)

Guide to good leak testing

How To Design A Refrigeration System

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

Chapter 2 Chemical and Physical Properties of Sulphur Dioxide and Sulphur Trioxide

User s Manual Laminar Flow Elements

Meriam Instrument LFE Data Sheet

Flashing and Cavitation

Anti-Cavitation Trim. Eliminates cavitation damage Reduces noise Preserves valve and surrounding pipe systems. singervalve.com

Proportional Relief Valves

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Regulator Performance Data

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

11.6 Formulas to be used when changing atmosphere in an tank

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Transcription:

CHOOSING THE CORRECT REGULATOR HOW TO SIZE A PRESSURE REGULATOR In order to choose the correct regulator the following information is needed: - Function: Pressure reducing or backpressure control? - Pressure: What are the maximum and minimum inlet and outlet pressure ranges? - Fluid: Is it a gas or a liquid? - Temperature: What is the operating temperature? - Flow: What are the flow requirements? Valve sizing does not refer to the size of the end connections. It means determining how much flow can pass through the pressure regulator. There is quite a difference in sizing regulators for gas or for liquids, because gases are compressible and liquids are not. SIZING FOR LIQUIDS The flow equations used for sizing for liquids have their roots in: - Bernouilli s energy equation - the continuity equation The continuity equation states that the volume flow (Qv) flowing through a pipe cross-section (A) in a unit of time is always constant. Qv = A x V(velocity). This implies that velocity must increase as the cross-section becomes smaller to maintain the same volume flow. The conclusion is that because liquids are incompressible, their flow rate depends only on the pressure drop. As long as the difference between P1 and P2 is the same, the flow is the same, no matter if the system pressure is high or low. Important: It is important to realize that whatever goes through the regulator seat will go though the outletport of the regulator. However, we want controlled pressure, not pressure drop or noise. To keep this pressure drop and noise within acceptable limits a rule of thumb says that velocities should not exceed: 1m/sec : suction side of reciprocating pumps 2m/sec : suction side of centrifugal pumps 1m/sec : return line of pumps 4,5 m/sec: delivery side of pumps Another rule of thumb says not to exceed a velocity of 4,5 m/sec for pressure above 7 bar. Calculate a velocity in a pipe: Formula: V = 278 Q A V = m/sec Q = m 3 / hr A = area in mm 2 As A = ¼ Πd 2, you can also calculate the diameter. Effects of specific gravity (s.g.) The significance of s.g. on liquid flow is diminished because it is a square root function. Only if the s.g. is very high or very low will the flow change by more than 10 % from that of water. Effects of temperature. As the effects are too small these can be ignored.

SIZING FOR GASES General information Because gases are compressible sizing for gases is not as straightforward as sizing for liquids. The density of gases changes with pressure. Orifices There are two orifices (holes) in a regulator which need to be looked at: 1 the seat orifice 2 the outlet orifice The seat orifice. This is a restriction inside the regulator body. When a flowing fluid ( gas or liquid) flows through a restriction into a lower pressure environment the velocity MUST increase as this fluid flows through this restriction. (Conservation of mass). At the same time the pressure decreases. If the pressure decreases to a point where the P1 = 1.7-1.9 x P2 or more, we have a choked flow situation, where the velocity through the restriction becomes sonic. This situation is also called critical flow. A choked flow condition is a limiting one, because, even if the downstream pressure increases further ( to zero for example), the flow cannot increase. Gas cannot achieve a velocity greater than sonic. Thus, if the pressure drop is big enough the seatflow depends on the inletpressure and not on the outletpressure. See maximum flow. If we have a non-critical flow, when P2 is more than 0,5 x P1, the flow through the seat is restricted by the high outletpressure. This is the situation where we need to apply the correction factor (Y). One can also use the seatsizing formula to calculate the maximum flow through any particular regulator. Example: The maximum airflow through model RS6, with 10 bar inlet pressure is: 0.33 x 11 x 67 = 243 Nm³/ hour of air. (Does not apply to regulators with filters.) This is the flow which a safety valve should be able to pass. The first thing to do is to calculate the seat orifice area A1. The outlet orifice A rule of thumb says that energy cannot be destroyed. It means that whatever quantity one can feed through a seat will come out of the regulator. However.. the question is in what form will this energy come out of the regulator. As velocity, noise, temperature or droop? All we want is: controlled outlet pressure with as little as possible droop. To achieve that we have to look at orifice number 2.. the outlet. In order to achieve this controlled outlet pressure we have to keep the velocity of the fluid on the P2 side at an acceptable level. For gases in general this is: 25-30 m/sec. and for liquids 4,5-5 m/sec. This of course is a rule of thumb. Now we calculate the required outlet orifice area while assuming a certain velocity. The formula tells us that a given flow at a certain pressure requires a certain area in order to flow through that area at the assumed velocity.

ACTUAL SIZING FOR GASES The following information is required to select the most suitable regulator: - the maximum and minimum inlet and outlet pressure - the fluid - the flow requirement - the temperature - materials of construction The next step is to calculate the: - seat orifice area (A1) : the flow area between a valve stem and the seat with the valve fully opened. - outlet port area (A2) : the area of the internal passage in the regulator outlet connection. Please note that the following formulae are used to determine the flow of air through a regulator. Correction factors for other gases are shown on the next page. Calculating the seat orifice area (A1) Use the formula: 0.33 x A1 x P1 = Q1 (does not apply to regulators with filters). A1 = seat orfice area in mm² P1 = inletpressure in bar (a) Q1 = max. flow of air in Nm³/hour through the seat orifice area. Normally the customer gives you the flow (Q1) and the gas. If the gas is not air convert the gasflow to airflow. The customer should also give you the inletpressure (P1) and the outletpressure (P2). Knowing these 3 parameters you can calculate the seat orifice area (A1). Remember! If you know 3 out of 4 parameters you can always calculate the unknown fourth. Non-choked flow A non-choked flowsituation ( or non-critical) occurs when the outlet pressure (P2) is more than half the inlet pressure (P1). P2 > 0,5 x P1 Simply said you need a bigger seat orifice area to pass a flow, because of the small pressure differential. To make sure that the sizing is correct multiply seat area flow Q1 by correction factor Y. Correction factor Y P2 (in bar abs.) P1 (in bar abs.) Multiplyer Y 0,975 0,1 0,95 0,31 Formula: 0,33 x A1 x P1 x Y =Q1 0,925 0,52 0,9 0,6 0,85 0,71 0,8 0,8 0,75 0,86 0,7 0,91 0,65 0,95 0,6 0,98 0,55 0,99 0,5 1

Maximum flow To determine the maximum flow through a regulator use either: - the seat orifice area formula, or - the nomograph. As long as there is a choked (critical) flow, (P1 = 2 x P2 at least), the flow which you will find on the nomograph is the maximum flow with the valve wide open. The nomograph also allows you to find the maximum flows for smaller differential pressures. The flows which you find for any given pressure differential can be used for sizing a relief valve. Note! The nomograph does not say anything about accuracy, it just gives you maximum flows. Calculating the outlet port area (A2) Use the formula: 0,10 x A2 x P2 = Q2 (assuming a velocity in the downstream piping of 30 M/sec.) 0,18 x A2 x P2 = Q2 (assuming a velocity in the downstream piping of 50 M/sec.) 0,30 x A2 x P2 = Q2 (assuming a velocity in the downstream piping of 75 M/sec.) A2 = outlet port area in mm² P2 = outlet pressure in bar abs Q2 = flow of air in Nm³/hour through the outlet port area at the selected velocity. Remember that Q2 is the flow which the customer has given you. Correction for other gases Multiply the maximum airflow through the seat area (Q1) by the following factors to obtain the specific gas flow. Hydrogen : 3,81 Nitrogen : 1,02 Oxygen : 0,95 Helium : 2,695 Argon : 0,85 Neon : 1,28 Carbon dioxide : 0,8 Carbon monoxide : 1,0 Ammonia : 1,27 Methane : 1,8 Acetylene : 1,05 Chlorine : 0,64 Ethane : 1,0 Ethylene : 1,03 Hydrogen sulphide : 0,93 Nitrous oxide : 0,83 Propane : 0,82 Sulphur dioxide : 0,68 Lpg : 0,8 Natural gas : 1,30

USEFULL DATA 1 mbar = 1 hpa = 10 mm w.c. 1 kpa = 10 mbar 1 bar = 100 kpa 1 MPa = 10 bar 1 mm Hg = 1,333 mbar 1 Hg = 33,858 mbar 1 UK gallon = 4,55 L 1 US gallon = 3,785 L 1 m 3 = 35,315 ft 3 C = 5/9 ( F 32) F = 9/5 ( C + 32) K = C + 273,15 Cv value Cv value is the flowcoefficient indicating the flow of water in U.S.gallons/min at a ΔP of 1 psi and a watertemperature of 60 F. Kv value Kv value is the flowcoefficient indicating the flow of water in m 3 /hr at a ΔP of 1 bar and a watertemperature of 5-30 C. Kv = 0,86 x Cv Kvs value Kvs value is the Kv value with the valve fully open. Gives the maximum possible flow through a regulator. RULE OF THUMB Size a regulator based on the largest possible flow and the smallest ΔP. Should you come close to the limit of a regulator take the next larger one. Note Our formulas apply to ordinary gases and liquids. They do not apply to gases or vapours near or at the point of liquefaction. Also they do not apply to boiling or very viscous liquids. Safe Product Selection When selecting a product, the total system design must be considered to ensure safe, troublefree performance. Function, material compatibility, adequate ratings, proper installation, operation, and maintenance are the responsibilities of the system designer and user. RHPS, Swagelok TM Swagelok Company 2010 Swagelok Company Printed in U.S.A., OM June 2010, R0 MS-02-369-E