80 Series - Modular timers 6 A 80. Multi-function and mono-function timer range - Multi-function & multi-voltage 80. - ON delay, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN 6075) mount Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip New multi-voltage versions with PWM clever technology / 80. Multi-function AI: ON delay DI: ON pulse SW: Symmetrical recycling: ON start BE: Signal OFF delay CE: Signal ON and OFF delay DE: Signal ON pulse AI: ON delay 80. FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Rated current/maximum peak current A Rated voltage/maximum switching voltage V Rated load Rated load 5 (230 V ) Single phase motor rating (230 V ) kw Breaking capacity : 30/0/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification V Rated power / (50 Hz)/W Electrical life at rated load in cycles (with signal START) CO (SPDT) CO (SPDT) 6/30 6/30 250/400 250/400 4,000 4,000 750 750 0.55 0.55 6/0.3/0.2 6/0.3/0.2 500 (0/5) 500 (0/5) AgCdO AgCdO 2 240 24...240 2 240 24...240 <.8 / < <.8 / < (0.8...265)V (0.8...265)V (0. 2)s, ( 20)s, (0. 2)min, ( 20)min, (0. 2)h, ( 24)h ± ± 50 50 50 ± 5 ± 5 00 0 3 00 0 3 IP 20 IP 20
80 Series - Modular timers 6 A 80.2 80.4 80.9 Mono-function timer range 80.2 - ON pulse, multi-voltage 80.4 - Signal OFF delay, multi-voltage 80.9 - Asymmetrical recycling, multi-voltage 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN 6075) mount Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip New multi-voltage versions with PWM clever technology 80.2 / 80.4 / 80.9 DI: ON pulse BE: Signal OFF delay LI: Asymmetrical recycling (ON starting) LE: Signal asymmetrical recycling (ON starting) 80.2 80.4 80.9 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Rated current/maximum peak current A Rated voltage/maximum switching voltage V Rated load Rated load 5 (230 V ) Single phase motor rating (230 V ) kw Breaking capacity : 30/0/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification V Rated power / (50 Hz)/W Electrical life at rated load in cycles (with signal START) (without signal START) CO (SPDT) CO (SPDT) CO (SPDT) 6/30 6/30 6/30 250/400 250/400 250/400 4,000 4,000 4,000 750 750 750 0.55 0.55 0.55 6/0.3/0.2 6/0.3/0.2 6/0.3/0.2 500 (0/5) 500 (0/5) 500 (0/5) AgCdO AgCdO AgCdO 24...240 24...240 2...240 24...240 24...240 2...240 <.8 / < <.8 / < <.8 / < (0.8...265)V (0.8...265)V (0. 2)s, ( 20)s, (0. 2)min, ( 20)min, (0. 2)h, ( 24)h ± ± ± 50 50 50 50 50 ± 5 ± 5 ± 5 00 0 3 00 0 3 00 0 3 IP 20 IP 20 IP 20 (with signal START) 2
80 Series - Modular Solid State timer (SST) A Multi-function and multi-voltage solid-state output timer 7.5 mm wide Six time scales from 0.s to 24h 35 mm rail (EN 6075) mount output (24...240 V /), independent from the input voltage Blade + cross - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip input with PWM clever technology Multi-function AI: ON delay DI: ON pulse SW: Symmetrical recycling: ON start BE: Signal OFF delay CE: Signal ON and OFF delay DE: Signal ON pulse (with signal START) Output circuit Rated current A Rated voltage V / Switching voltage range V / Rated load 5 A Rated load A Minimum switching current ma Max. OFF-state leakage current ma Max. ON-state voltage drop V Input circuit V Rated power (50 Hz)/W Electrical life cycles NO (SPST-NO) 24...240 9...265 0.5 0.05 2.8 24...240 24 240.3/.3 (9...265)V (9...265)V (0...2)s, (...20)s, (0...2)min, (...20)min, (0...2)h, (...24)h ± 50 50 ± 5 00 0 6 20 +50 IP 20 3
80 Series - Modular timers 6-8 A Mono-function timer range 80.6 - True OFF delay, multi-voltage 80.82 - Star-Delta timer, multi-voltage 7.5 mm wide Rotary range selector, and timing trimmer Four time scales from 0.s to 20s (type 80.6) Six time scales from 0.s to 20min (type 80.82) 35 mm rail (EN 6075) mount 80.6 / 80.82 BI: True Off Delay 80.6 80.82 Transfer time can be regulated (0.05 )s SD: Star-Delta 80.6 80.82 FOR UL HORSEPOWER AND PILOT DUTY RATINGS SEE General technical information page V Contact specification Rated current/maximum peak current A Rated voltage/maximum switching voltage V Rated load Rated load 5 (230 V ) Single phase motor rating (230 V ) kw Breaking capacity : 30/0/220 V A Minimum switching load mw (V/mA) Standard contact material Supply specification V Rated power / (50 Hz)/W Electrical life at rated load in cycles CO (SPDT) 2 NO (DPST-NO) 8/5 6/0 250/400 250/400 2,000,500 400 300 0.3 8/0.3/0.2 6/0.2/0.2 300 (5/5) 500 (2/0) AgNi AgNi 24...240 2...240 24 240 2...240 < 0.6/ < 0.6 <.3/ < 0.8 (0.2...265)V (0.2...265)V (0...)s, (0.5...5)s, (...0)s, (2...20)s (0...2)s, (...20)s, (0...2)min, (...20)min ± ± 50 50 300 (A-A2) ± 5 ± 5 00 0 3 60 0 3 IP 20 IP 20 4
Ordering information Example: 80 series, modular timers, CO (SPDT) - 6 A, supply rated at (2 240)V /. 80 Series - Modular timers - 6-8 - 6 A 8 0. 0. 0. 2 4 0. 0 0 0 0 Series Type 0 = Multi-function (AI, DI, SW, BE, CE, DE) = ON delay (AI) 2 = ON pulse (DI) 4 = Signal OFF delay (BE) 6 = True OFF delay (BI) 7 = Multi-function with solid state output (AI, DI, SW, BE, CE, DE) 8 = Star-Delta (SD) 9 = Asymmetrical recycling ON starting (LI, LE) Versions 0 = Standard 2 = Standard (for type 80.6 only) Supply voltage 240 = (2... 240)V / (, 80.82, 80.9) 240 = (24... 240)V / (80., 80.2, 80.4, 80.6, ) Supply version 0 = (50/60 Hz)/ No. of poles = CO (SPDT) = NO (SPST-NO), type only 2 = 2 NO (DPST-NO), type 80.82 only Insulation Dielectric strength //2/4/82/9 80.6/7 between input and output circuit V 4,000 2,500 between open contacts V,000,000 Insulation (.2/50 µs) between input and output kv 6 4 EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 6000-4-2 4 kv air discharge EN 6000-4-2 8 kv Radio-frequency electromagnetic field (80 000 MHz) EN 6000-4-3 0 V/m Fast transients (burst) (5-50 ns, 5 khz) on Supply terminals EN 6000-4-4 4 kv Surges (.2/50 µs) on Supply terminals common mode EN 6000-4-5 4 kv differential mode EN 6000-4-5 4 kv on start terminal (B) common mode EN 6000-4-5 4 kv differential mode EN 6000-4-5 4 kv Radio-frequency common mode (0.5 80 MHz) on Supply terminals EN 6000-4-6 0 V Radiated and conducted emission EN 55022 class B Other data Current absorption on signal control (B) < ma Power lost to the environment without contact current W.4 with rated current W 3.2 Screw torque Nm 0.8 Max. wire size solid cable stranded cable mm 2 x6 / 2x4 x4 / 2x2.5 AWG x0 / 2x2 x2 / 2x4 Accessories Sheet of marker tags, for types 80.6/82, plastic, 24 tags, 9x7 mm 020.24 020.24 Sheet of marker tags, for types //2/4/7, plastic, 72 tags, 6x2 mm 060.72 060.72 5
80 Series - Modular timers - 6-8 - 6 A Functions U = Supply voltage S = Signal switch = Output contact LED* Supply voltage OFF NO output contact 5-8 Contacts Closed 5-6 ON 5-8 5-6 ON (Timing in Progress) 5-8 5-6 ON Closed 5-6 5-8 * The LED on type 80.6 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED is not illuminated. Without signal START Type Without signal Start = Start via contact in supply line (A). With signal Start = Start via contact into control terminal (B). (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. (SW) Symmetrical recycling: ON start. Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is : (time on = time off). With signal START (BE) Signal OFF delay. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). ing the Signal Switch initiates the preset delay, after which time the output contacts reset. (CE) Signal ON and OFF delay. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. ing the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Signal ON pulse. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. NOTE: The function must be set before energising the timer. Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B. * With supply, positive polarity has to be connected to B terminal (according to EN 60204-). ** A voltage other than the supply voltage can be applied to the command Start (B), example: A - A2 = 230 V B - A2 = 2 V 6
80 Series - Modular timers 6-8 - 6 A Functions Without signal START Type 80. (AI) ON delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 80.2 (DI) ON pulse. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 80./2/6 80.6 (BI) True OFF delay (power OFF). Apply power to timer (minimum 300). Output contacts transfer immediately. Removal of power initiates the preset delay, after which time the output contacts reset. 80.82 With signal START 80.82 80.4 (SD) Star - delta. Apply power to timer. The star contact ( ) closes immediately. After preset delay has elapsed the star contact ( ) resets. After a further transfer time variable from (0.05 )s the delta contact ( Δ ) closes and remains in that position, until reset on power off. (BE) Signal OFF delay. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). ing the Signal Switch initiates the preset delay, after which time the output contacts reset. 80.4 Without signal START 80.9 (LI) Asymmetrical recycling (ON start). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ON (T) and OFF (T2) times are independently adjustable. 80.9 With signal START (LE) Signal asymmetrical recycling (ON start) Power is permenently applied to the timer. Closing Signal Switch (S) causes the output contacts to transfer immediately and cycle between ON (T) and OFF (T2), until opened. 80.9 Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B. * With supply, positive polarity has to be connected to B terminal (according to EN 60204-). ** A voltage other than the supply voltage can be applied to the command Start (B), example: A - A2 = 230 V B - A2 = 2 V 7