Dynatel. 965DSP Subscriber Loop Analyzer



Similar documents
Advanced Systems Tester 900AST

Diagnostic Test Equipment

Dynatel Advanced Modular System 965AMS 30-Megahertz Spectrum Analyzer

3M Dynatel Triple Play Customer Service Test Set INS970

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

UltraFED IIB. 30 MHz Far-End Device

Insulation resistance testing. A complete solution for every person.

3 Dynatel Advanced Modular System 965AMS

Dynatel 2273 Advanced Cable and Fault Locator

SVPRIBOR ALFA DSL. Users Manual

3M Dynatel Triple Play Customer Service Test Set INS970

LT-82 Stationary IR Transmitter

User's Guide. True RMS Industrial Multimeter

5000V Graphical Megohmmeter Model 5070

AXS-200/ MHz COPPER TEST SET. part of the SharpTESTER Access Line. Telecom Test and Measurement

Multi-Function Ground

TRIPLETT TDR. Cable Fault Finder. Instruction Manual

Handheld portable appliance testers

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

iva Cable & Antenna Analyzer

3M Quick Connect System (QCS) 2814

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Copper Testing for ADSL/2/2+ Qualification and troubleshooting of the local loop

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Hand-held thermometer Model CTH7000

DC Electronic Loads 8500 series

3M Integrated Splitter Block BRCP-SP

i410/i1010 AC/DC Current Clamp

How To Sell A Talan

CellAdvisor. JD725A Dual-Port Cable and Antenna Analyzer

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Fluke 3000 FC Series Test Tools Technical Data

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Fluke 1650B Series Multifunction Installation Testers

Physical Specifications (Custom design available.)

Dielectric Withstand and Ground Bond Testers For Production Line Safety Agency Compliance Testing

3M Twisted Pair Flat Cable.050" 28 AWG Stranded, Mass Terminatable Pair, PVC 1700 Series

Spectrum Analyzer Two models available: OGR-24 (24 GHz) and OGR-8 (8 GHz)

HVAC Clamp Meter. Users Manual

AutoRanging Digital MultiMeter

MIT510/2, MIT520/2 and MIT1020/2

iva Cable & Antenna Analyzer

3M Quick Connect System (QCS) 2810 Models 2810A and 2810B

3 740 Wrist strap + shoe tester

ACL 395 Resistivity Meter

Signal Conditioning Amplifier System

3M Wrist Strap and Footwear Tester 740. User s Guide

DET3 and 4 Contractor Series Earth/Ground Resistance Testers

User Guide. Model Insulation Tester / Megohmmeter

3M High Flex Life Cable.050" 28 AWG Stranded, PVC 3319 Series

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

U1602A Handheld Oscilloscopes, 20 MHz

COUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

rigel 288 Electrical Medical Safety Analyser Key Features Applications

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

How To Use A Cdm250 Digital Multimeter

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

10 Multimeter. Users Manual

1650 Series Multifunction Installation Testers

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Miniature Surface-Mount DAA for Audio or Data Transfer XE0402LCC BLOCK DIAGRAM

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

ACL 800 MEGOHMMETER OPERATION MANUAL

T-BERD 107A. T-Carrier Analyzer

QuickSpecs. Models HP 4110 IP Phone

Unattended Answering Device Instruction Manual

DET3 Contractor Series 3-Terminal Earth/Ground Resistance Testers

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

MACTek Corporation. USB HART Interface. Users Manual

Nardalert S3 Non-Ionizing Radiation Monitor

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

M310 Data Center OTDR

Discontinued. Volition. Fiber Optic Cable. 3Innovation

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

PagePac PAGEPAL V

Power Supplies 3. SDN-P DIN Rail Series

Digital Transformer Ratiometer DTR Model 8500

Technical Data FLIR E40bx (incl. Wi-Fi)

Safety Information. 2 Safety Information

Fluke 3000 FC Series Test Tools Technical Data

0.9V Boost Driver PR4403 for White LEDs in Solar Lamps

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Your perfect solution for testing cables and antennas in today s communication networks. Agilent N9330B Handheld Cable and Antenna Tester

TCB-2 Auto Answer Coupler Product Manual

Voltech DC1000. Precision DC Bias Current Source

Mobile Communications DC Sources W

Custom Products. Magnetic Components. Vishay Dale.

User Manual. CFG253 3 MHz Function Generator

TOOLS DIAGNOSTIC. The information presented in this chapter is organized as follows: Quick reference tables. Detailed product specifications.

AXIS T81B22 DC 30W Midspan

Transcription:

3 Dynatel 965DSP Subscriber Loop Analyzer 1

Complete testing of POTS and ISDN subscriber loops The 3M Dynatel 965DSP Subscriber Loop Analyzer is a microprocessor-controlled integrated test set that provides full-featured POTS and wideband testing. The functions include fault location and repair verification on twisted-pair, quad and coaxial cable (utilizing capacitance bridge, resistance bridge and Time Domain Reflectometer (TDR) functions). The Dynatel 965DSP subscriber loop analyzer executes a wide range of individual tests, or performs automatic test routines to categorize and sectionalize problems. Specific tests and measurements performed by the unit include: Voltage detects and measures the presence of central office (exchange) or foreign DC or AC voltages. Tone provides test tones for conductor identification and transmission testing. 10 default tones, user selectable as ID tone, voiceband, or wideband. Wideband goes up to 1.2 MHz, voiceband to 20 khz, ID tone to 1000 Hz. Current measures DC loop current. Resistance measures conductor and insulation resistance up to 1000 megohms. TDR full-featured TDR with user-selectable pulse widths, length, gain zoom, filter and Vp. Five modes of operation: Single trace provides graphical representation of events on a pair. Dual trace allows active comparison of two traces. Differential displays difference between two circuits. Crosstalk displays the crosstalk from one pair to another. Memory allows comparison of an active trace with a trace stored in memory. Peak displays a history of maximum and minimum values with the live trace. Resistive fault location displays distance to fault. Opens locates opens at distances up to 100,000 ft. (30 km). Load coil count indicates the presence of load coils in a loop circuit and distance to the first load coil. Wideband loss loss measurements to 1200 khz for pre-qualifying ISDN, HDSL and ADSL. Loss measures voiceband loss. Noise measures noise metallic and noise to ground in dbrnc or dbm0p. Longitudinal balance provides active measurement of line balance. Autotest allows an automatic test of active, inactive and wideband (56K/64K DDS, ISDN, HDSL, T1, E1 and ADSL) lines with pass/fail limits. Ground resistance allows the 965DSP to measure the resistance of the ground path. Special resistance allows the 965DSP to measure the loop resistance and the resistance difference between two conductors on a pair. K-Test allows RFL measurement when both wires in a pair are faulted and there is no separate good pair available. 3M Dynatel 965DSP with 3M Far End Device 2 Ringers measures and displays capacitance associated with one or more ringers and the equivalent count. Level Trace measures and displays the AC impedance of the unterminated line as a function of frequency. 3M s FED and CTCs Smartstrap support for wideband auto test. Flexible, practical features The 965DSP subscriber loop analyzer is designed for functionality and ease of use. Features of the unit include: IR port infrared port for downloading future software programs and uploading test results to a PC or printer. Self-calibration internal instrument calibration and set-up procedures. Graphical user interface user-friendly, icon-based display of test results. Replaceable test leads. HELP function an internal help menu provides information as needed during operation. Telephone internal telephone or talk set. Rechargeable nickel metal hydride batteries with battery charger and alkaline battery holder. Object oriented software design for easy upgrades, investment protection. Backlit high resolution/high contrast LCD display. Rugged, weather resistant design The hand-held 965DSP test set is housed in a lightweight, ergonomically designed case for portability and ease of handling. The unit is weather-resistant and weighs only 3.3 pounds (1.5 kg). The Dynatel brand and its distinctive Dynatel yellow cases are your assurance of rugged dependability.

3 4 5 RFL Strap 6 AD/DC Adapter Cable 7 3M Dynatel 965DSP Subscriber Loop Analyzer Electrical Specifications Main Functions Range Resolution Accuracy Voltage (DC) 0 to 99.9 V 0.1 V 1% ± 0.5 V 100 to 300 V 1 V 3% Voltage (AC) 0 to 99.9 V 0.1 V 1% ± 0.5 V 100 to 250 V 1 V 3% Current 0 to 59.9 ma 0.1 ma 1% ± 0.3 ma 60 to 110 ma 0.1 ma 2% Resistance (DC) 0 to 9999 Ω 1 Ω 1% ± 5 Ω with CO voltage 0 to 9999 Ω 1 Ω 1% ± 50 Ω 10 k to 99.9 kω 0.1 kω 1% 100 k to 999 kω 1 kω 3% 1 M to 9.9 MΩ 0.1 MΩ 3% 10 M to 99 MΩ 1 MΩ 5% 100 M to 990 MΩ 10 MΩ 10% Opens (no noise) 0 to 3,000 ft (0 to 1000 m) 1 ft (1 m) 1% ± 3 ft (1 m) 3,000 to 10,000 ft (1 km to 3 km) 1 ft (1 m) 3% 10,000 to 50,000 ft (3 km to 15 km) 10 ft (10 m) 5% 50,000 to 100,000 ft (15 km to 30 km) 100 ft (100 m) 10% RFL Fault range 0 to 20 MΩ Resistance to 0 to 99.99 Ω RTS 0.01 Ω 0.1% of RTS ± 0.01 Ω fault (no noise) 100 to 999.9 Ω RTS 0.1 Ω 0.2% of RTS ± 0.01 Ω 1 kω to 7 kω RTS 1.0 Ω 1.0% of RTS ± 0.01 Ω Loss (& frequency) -40 to +10 dbm, 200 to 3000 Hz 0.1 db, 1 Hz 0.5 db, 2 Hz with 600 Ω Zin -40 to +10 dbm, 3000 to 9995 Hz 0.1 db, 5 Hz 0.5 db, 10 Hz -40 to +10 dbm, 10 k to 19.9 khz 1 db, 10 Hz 1 db, 20 Hz Wideband loss 135 Ω Zin -50 to +2 dbm, 20 k to 1200 khz.1 db, 100 Hz 2 db, 1% Noise metallic 600 Ω Zin 0 to 50 dbrnc (-90 to -40 dbm0p) 1 db 2 db Noise to ground 600 Ω Zin 40 to 100 dbrnc (-50 to 10 dbm0p) 1 db 2 db Longitudinal balance 0 to 85 db 1 db 2 db Tone output ID 200 to 1000 Hz, fixed level 1 Hz 1% Precision - 600 Ω Zout 200 to 9999 Hz, -20 to +1 dbm 1 Hz, 0.1 db 1% Hz, 0.2 db 10 k to 19.99 khz, -20 to +1 dbm 1 Hz, 0.1 db 2% Hz, 1 db Wideband - 135 Ω Zout 0 dbm, 20 k to 1200 khz 1 khz 1 db Dial mode DTMF, Pulse Standard Standard TDR* Ranges 3 ft 300 ft, 20 ft 1,000 ft, 1 ft (1 m) 0.6% range 50 ft 3,000 ft, 150 ft. 10,000 ft, 450 ft 30,000 ft (1 100 m, 5 300 m, 15 1,000 m, 45 3,000 m, 140 10,000 m) Pulse width 5 ns, 34 ns, 235 ns, 1600 ns Fixed values Velocity input 0.50 to 0.99 (150 to 299 m/µs) 0.01 (1 m/µs) Modes Single trace, dual trace, differential, memory, crosstalk ISDN Link test Active/inactive Error test (U.S. & Canada only) Near-end & far-end block errors 1 error 1 error Auto Same specifications as full tests See above See above *Not included in 965DSP-B version; available as optional factory upgrade. Physical Specifications Size 10.0"H x 4.0"W x 2.5"D (25 cm x 10 cm x 6 cm) Net weight 3.3 lb. with battery and soft case (1.5 kg) Shipping weight 7 lb. (3.17 kg) Material High-impact grade ABS

AC/DC Adapter 8 Battery Holder 9 Battery Pack 10 3M Dynatel 965DSP Subscriber Loop Analyzer Environmental Specifications Far End Device 11 Operating temperature 0 to 140 F (-18 to 60 C) Storage temperature -40 to 165 F (-40 to 75 C) Humidity 0-95%, non-condensing Accessories Test leads RFL strap AC/DC adaptor Soft case Battery holder Battery pack U.S. Five 5 ft (1.5 m) test leads with 2 mm gold-plated banana plugs one end and chrome-plated alligator clips on other end (black/red, blue/yellow, green) European Five 5 ft (1.5 m) test leads with 2 mm gold-plated banana plugs one end and 4 mm gold-plated banana plugs on other end (black/red, blue/yellow, green) U.S. 1.5 ft (0.5 m) with alligator clips on ends European 1.5 ft (0.5 m) with banana plugs on ends 100-250 Vac (50/60 Hz) input; 12 Vdc (1 A) output. For charging only. Do not operate when using adapter. Heavy-duty fabric case for unit and test leads Plastic holder for 6 AA (LR6) batteries Custom 1.2 amp-hour Nickel metal hydride Toolbox Functions Range Resolution Accuracy Load coil count 0 to 5 1 ±1 Ohms/distance 0-9999 ohms 0.01Ω calculator 0-99999 ft (0-30 km) 1 ft (0.1 m) Caller ID (U.S. & Canada only) Date, time, number, name Carrier level -4 to -32 dbm 1 dbm 2 dbm Self-calibrate Pass/Fail Loop resistance 0 to 99.9 Ω 0.01 Ω 0.1% ± 0.01 Ω 100 to 999.9 Ω 0.1 Ω 0.2% ± 0.01 Ω 1000 to 7000 Ω 1 Ω 1.0% ± 0.01 Ω Resistance difference 0 to 99.99 Ω 0.01 Ω 1% of loop resistance ± 0.01 Ω Ground resistance 5 to 500 Ω 1 Ω 1% ± 1 Ω K-Test Loop resistance 0 to 7K Ω Fault ratio Resistance to fault (Fault Res1) > twice (Fault Res2) 0 to 99 Ω 0.01 Ω 5% (no noise) 100 to 999 Ω 0.1 Ω 5% 1K Ω to 3.5K Ω 1 Ω 5% Stored results 100 results of each, minimum (Auto Test and TDR) Ringers 0.0 to 4.0 0.1 Ω 0 to 2000 nf 10 nf General Specifications Ruggedness Water-resistance Standards Language Units Battery life Charging time Keypad Display Note: Routine calibration is not recommended or required. Survives 5 ft (1.5 m) drop in soft case Splash-proof; may be used in light to moderate rain Meets FCC part 15, class A: Digital Devices for the US, and EN55022 (radiated emissions), EN55024-2 (electrostatic discharge), EN55024-3 (radiated immunity) EN55024-4 (transient immunity) and IEC1010 (product safety) for Europe. Built to ISO9001 certification for manufacturing facilities. Built to Bellcore (Telcordia Technologies) TSY000078 manufacturing methods. Meets UL50 Rain Test. English, Spanish, French, German, Danish, Italian, Canadian French Feet or meters, Fahrenheit or Celsius, dbrnc or dbm0p, m/us or Vf Rechargeable battery pack, 12 hours typical usage (no backlight), 4 hours typical (with backlight); typical usage defined as 30 minutes on, 30 minutes off 2 hours from low to full, typical 24-key membrane keypad with tactile feedback 2.5" x 2.5" (74 x 74 cm), 192 by 192 pixel resolution, backlight

Back On/Off Contrast/ Backlight Tab Setup Voltage Current Toolbox Opens RFL Save Enter Help Up Resistance Down Tone Left TDR Right ISDN Loss/Noise Talk Set Autotest

3M Dynatel 965DSP Subscriber Loop Analyzer Inactive Inactive Inactive Active Wideband Wideband Test Pair Pair Pair Pair w/fed w/fed Full w/o FED w/fed Basic w/fed Full w/o FED Basic Basic Full Volts Yes Yes Yes Yes Yes Yes Yes Ohms Yes Yes Yes Yes No Yes Yes Opens Yes Yes Yes Yes No Yes Yes Longitudinal balance Yes Yes Yes Yes Yes Yes Yes Sweep loss No No No Yes No No Yes Single tone loss No No Yes Yes Yes Yes Yes Loop resistance No No No Yes No Yes Yes Resistance balance No No No No No No Yes Load coils No Yes No Yes No Yes Yes Loop current No No No No Yes No No Noise No No No No Yes No No Power influence No No No No Yes No No Capacitive balance No No No No No Yes Yes Slope No No No Yes No No No Ordering Information To order, specify the appropriate 965DSP Subscriber Loop Analyzer which includes: analyzer, AC adaptor, AC power cord, test leads, alkaline battery holder, Stock Number Product Description UPC 80-6108-6390-6 965DSP-Subscriber Loop Analyzer 051138-57603 80-6109-9074-1 965DSP-B Subscriber Loop Analyzer 051138-58643 80-6109-9319-0 965DSP-European Model 051138-70088 80-6109-9203-6 965DSP-B TDR Upgrade Kit 051138-58770 Optional accessories 80-6108-6435-9 Black/red test lead, alligator, bed of nails 051138-57648 80-6108-6395-5 Black/red test lead, 4 mm banana, 1.5 m 051138-57608 80-6108-6436-7 Blue/yellow test lead, alligator, bed of nails 051138-57649 80-6108-6397-1 Blue/yellow test lead, 4 mm banana, 1.5 m 051138-57610 80-6108-6437-5 Green test lead, alligator, bed of nails 051138-57650 80-6108-6399-7 Green test lead, 4 mm banana, 1.5 m 051138-57612 80-6108-6472-2 Alkaline battery holder 051138-57685 80-6109-9059-2 110/220 Vac adapter 051138-57606 80-6108-6392-2 Soft case 051138-57605 80-6108-6473-0 Nickel metal hydride, battery pack 051138-57686 80-6109-3281-8 Cigarette lighter adaptor 051138-57744 80-6109-3830-2 Ground strap, alligator 051138-58529 80-6109-3833-6 Ground strap, 4 mm banana 051138-58532 80-6109-9197-0 IR Adapter Cable 051138-58764 80-6109-9320-8 1162 KM Box (K-test Adaptor) 051138-70089 80-6110-2035-7 Far end device 051138-89322 80-6110-2044-9 Printer IR Adapter 051138-89331 80-6110-2045-6 Seiko DPU-414 Printer Kit 051138-89332 Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M s current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. 3 Telecom Systems Division 6801 River Place Blvd. Austin, TX 78726-9000 800/426 8688 FAX 800/626 0329 http://www.3m.com/telecom conductor strap and operating manual. For further information, please contact your local 3M sales representative. Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture for a period of 12 months from the date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect, special, incidental or consequential regardless of the legal theory asserted. 40% Pre-consumer waste paper 10% Post-consumer waste paper Litho in USA. 3M 1999 80-6110-1445-9 (0797.5) xx-1