Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity

Similar documents
CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

LAMINAR AIRFLOW EQUIPMENT CLASS I BIOLOGICAL SAFETY CABINETS BIOLOGICAL ENCLOSURES

Laminar Flow Cabinets

BIOLOGICAL SAFETY CABINET PROGRAM

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

Air and Water Balancing - Sound and Vibration Testing - Cleanroom Services - Building Commissioning Building Envelope Testing Thermal Imaging

Stainless Steel Worksurface 3 Feet Hood A10-WS-PR3 A10-WS-SR3 4 Feet Hood A10-WS-PR4 A10-WS-SR4 6 Feet Hood A10-WS-PR6 A10-WS-SR6.

G U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice

Procedures for the Effective Use of Biological Safety Cabinets

Energy Savings With Adjustable Frequency Drives. for Centrifugal Fans

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions

SENTRY AIR SYSTEMS, INC. PHARMACEUTICAL COMPOUNDING CONTAINMENT SYSTEMS SIMPLE SOLUTIONS FOR CLEANER AIR

MAC 10. Original & IQ FAMILY OF FAN FILTER UNITS

Fume Hood Questions and Answers

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Risk Assessment: Biosafety Cabinet

HVAC Air Systems. Recirculation Air System Types

Laboratory Ventilation Safety. J. Scott Ward

Installation and Operating Manual Model F1800C Model F1800PG Model F1802C Model F1802PG Model F1806C Model F1806PG

Demand Based Static Pressure Reset Control for Laboratories

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Shakers, Incubators, Clean Benches, Water Baths, Drying Ovens

THE EFFECTS OF LAMINAR AIRFLOW IN SEMICONDUCTOR FABS ON THE VENTILATION DESIGN FOR EXHAUSTED ENCLOSURES

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

ECM MOTORS IN FAN POWERED TERMINAL UNITS

How To Save Energy On A Power Supply

Chemical Fume Hoods. Environmental Health and Safety

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

General Purpose Laminar Flow Cabinets, Horizontal and Vertical

FS209E and ISO Cleanroom Standards

VAV Laboratory Room Airflow The Lowdown on Turndown

Centrifugal Fans and Pumps are sized to meet the maximum

DATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

EACO DOP / PAO TESTING GUIDELINE 2013

Lab 8: DC generators: shunt, series, and compounded.

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

DUCT DESIGN FOR THE TIME CONSTRAINED WORLD

Glossary of Heating, Ventilation and Air Conditioning Terms

Sales and Support in the US and CA by: NuAire, Inc Fernbrook Lane Plymouth, MN

In Vitro Fertilization Workstation. Esco IVF Workstation, Model IVF-4A_. Shown with optional support stand.

Cooling Capacity CFM in. w.c. (125 Pa)

Today, healthcare facilities must be prepared to face

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Fan Basics and Selection Criteria (How to Use)

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

ACC1-10, ACC1-25, ACC1-50, ACC1-125

Geismar Site Reviewed: 07/05/16 Effective: 07/05/16 Supersedes: 08/04/14 Preparer: Owner: Approver: S/IH Team Leader S/IH Team Leader Manager LA Hub

Quick wins for energy savings in buildings

10 tips for servos and steppers a simple guide

Venturi Air Valve or Single-Blade Damper What s Right for You?

Cooling Capacity CFM in. w.c. (125 Pa)

G9MXE. Product Specifications

Fan Applications & System Guide

Digi-Motor Installation Guide

B-AIR BLOWER CUB POWER MODEL # CP-1

Spetec. Laminar Flow Box. Portable Clean Room Technology

Installation Manual CLIFC Fan & Coil Variable Speed

Laminar Flow Cabinets and Workstations

HEPA Filters for Pharma Applications Cleanrooms & Safety Applications. Gordon Farquharson June 2012

F9MXE. Product Specifications

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

How To Run A Data Center Efficiently

Downflo workstation DuSt ColleCtorS

CORROSION RESISTANT FRP FANS & BLOWERS

Basics of HVAC Cleaning

Duct Design. Presented by Dave Janquart

Data Center Cooling. The engineer s choice

Efficient and reliable fans, compressors and blowers

product application guide

ECM Blower Motor Replacement Controls Programming Process

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

Appendix A Primary Containment for Biohazards: Selection, Installation and Use of Biological Safety Cabinets

Greensource iseries HY Model Unitary Air Handler/Fan Coil

Camfil Farr Technical Services Bulletin

Ventilation Solutions Radon Mitigation

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

Environmental Monitoring of Clean Rooms

ECM. Service Guide.

Introduction. Motor Types

FAN PROTECTION AGAINST STALLING PHENOMENON

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Class II, Type A2 and B2 Biological Safety Cabinets The Most Certified Energy-Efficient, Safe, and Ergonomic Biosafety Cabinet in the World

Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Chapter 12 Industrial Ventilation

How To Install A Perfect 16 Id Series Filter System

AABC Specifications for Testing and Balancing HVAC Systems

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Terms of Reference Air Handling Unit (HVAC System) Cleaning

The following standard practices, safety equipment, and facility requirements apply to BSL-1:

St. Joseph s General Hospital, Vegreville EMERGENCY RESPONSE CODE GREY Shelter in Place / Air Exclusion

Biosafety Level 2 (BSL-2) Safety Guidelines

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

Unidrive M Energy Savings

Transcription:

Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity Best Products. Best Performance. Best Protection. NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A ph: 763.553.1270 fx: 763.553.0459 tf: 800.328.3352 www.nuaire.com

How Long are HEPA Filters suppose to last? The life of a HEPA filter for a Biological Safety Cabinet (BSC) is an important subject when considering the life cycle cost of any BSC. HEPA filter loading capacity has always been a major concern for the design and performance of a BSC. Not only in terms of replacement cost, but also in terms of laboratory safety through the replacement process, down time, and associated costs. With the use of new energy efficient motor technologies, expected HEPA filter loading capacity of BSC s may be reduced but still meet the NSF/ANSI 49 requirements. The discussion below provides a short explanation as to the requirements, what has changed, why it changed and what information is required from manufacturers to assure at a minimum the same HEPA filter loading capability. The energy savings obtained by using some of the new energy efficient motor designs of today may be offset by replacing the HEPA filters more often. History Class II, Type A2 Biological Safety Cabinet HEPA Filter Loading Capacity William Peters Vice President of Engineering The first major BSC specification developed by the National Institutes of Health (NIH) dating back to August 1973 included a specification for filter loading capacity. The NIH-03-112 specification scope and objective was to provide procurement specification for a safety cabinet that included downflow (which was new back then) along with inflow to provide both product and personnel protection. The cabinets would be used in biological research or production as an aid to control airborne contaminants, which may represent a low to medium risk hazard to scientific personnel and/or be deleterious to the equipment. The specification provided requirements for design, construction and performance of the original Class II, Type 1 (now type A1/A2) BSC s. Section 3.5.6 and 3.5.7.1 covered both the fan and motor respectively. Fan and motor performance were stated by the following requirements: 3.5.6.3 Total fan delivery shall fall off no more than 10% as a result of 50% increase in the pressure drop across the filter. 3.5.7.3 The motor shall be sized to operate the fan at a static pressure sufficient to meet the requirements of paragraph 3.5.6.3. To satisfy the above requirements, a fan curve provided by the fan manufacturer along with operational BSC static pressures and motor torque information provided by the motor manufacturer at the nominal airflow setpoint was plotted to theoretically calculate the loading capacity of the system. In this case, the system refers to the fan, motor and filters (with the specific pressure drops) of the individual BSC. 3

The NIH specification remained the only BSC specification until June 1976, when the National Sanitation Foundation (NSF) adopted Standard 49 Class II (Laminar Flow) Biohazard Cabinetry. The NSF Standard was based on the NIH specification; so many parts were nearly identical, if not the same including the fan and motor requirements as stated below. 4.21.2 Total air delivery shall fall off no more that 10% as a result of 50% increase in the pressure drop across the filter without readjusting the fan speed control. 4.22.1.2 The motor(s) shall be sized to operate the fan(s) at a static pressure sufficient to meet the requirements of item 4.21.2. Fan motors shall be UL or CSA listed. Again to satisfy the above standard requirements, cabinet manufacturers submitted a fan curve with the appropriated motor and static pressure information was provided to NSF as evidence of compliance to the standard requirement. In the late 1980 s an NSF task group was formed to develop a test method to demonstrate compliance to the standard versus providing theoretical evidence of compliance. The motor blower performance task group based the current test method on the Air Movement and Control Association (AMCA) publication 210, laboratory methods of testing fans for rating purposes. The basis of the test was to load the cabinet airflow system and measure the static pressures of the fan per AMCA, then measure airflow fall off to determine compliance to the statement above. The test method was officially updated in the 1992 revision of the standard and remains the same today per NSF/ANSI 49, Annex A.12, Motor / Blower Performance. Understanding the basis for the Specification: The design and performance basis for both of the above specifications was the use of an AC PSC motor and a forward curved fan. The AC PSC motor has an inherent design characteristic of increasing motor RPM with more resistance (Torque) or when used in a cabinet with a forward curved fan will increase RPM of the fan with more static pressure caused by particulate loading on the HEPA filters of the BSC. So, by specifying that no more than a 10% fall off of total air delivery from a 50% increase in static pressure assured the correct fan, motor and HEPA filters were designed into the BSC. The 50% increase in static pressure is considered the baseline without readjusting the fan speed control knowing that the fan speed control would add additional capacity to the system. Although, not specified by NSF, the additional capacity was virtually guaranteed using AC PSC motors and forward curved fans. Manufactures, provided what additional capacity they could offer that basically indicates how much particulate load can be applied to the system and still maintain cabinet airflows at a level to provide containment. Using available AC PSC motors, forward curved fans and HEPA filters with average pressure drops, most manufacturers were able to attain 180% increase in pressure drop or static pressure across the filter with no more than a 10% fall off in total air delivery. The 180% increase in pressure drop then became the de facto industry standard being used and published by most manufactures and written into most all architectural, governmental, university and private industry BSC specifications. 4

The following statement in some form represents this specification used today: Cabinet motor/blower shall be positioned so as to create even filter loading, thereby prolonging the life of the HEPA filters, and shall deliver over 50% of the initial HEPA filter static pressure with no more than a 10% decrease of total CFM. Equip each cabinet with a voltage compensating motor speed controller that automatically compensates for voltage changes to maintain constant voltage to motor. Speed controller will permit manual or automatic adjustment to deliver over 180% of the initial HEPA filter static pressure with no more than a 10% decrease of total CFM. HEPA Filter Life: Since actual filter loading in the field is based upon the laboratory environment the BSC is used in, actual life of the HEPA filters will vary for each installation. If the BSC was installed in a clean room, theoretically the filters will last forever. If the BSC was installed in an environment that has or generates a lot of particulates, the filters won t last as long. To establish average filter life in a standard life science laboratory, historical data was reviewed as to when replacement HEPA filters were ordered. Based on NuAire data and knowing our AC PSC motor design provides a 180% increase in pressure drop, it was found that filters were lasting an average of 7 years. Using 7 years as a benchmark for 180% increase in pressure drop, the following chart was then established equaling average filter life to percent increase in pressure drop or filter loading capacity. As you might note, the chart is not linear, but is similar to that of a fan curve that allows more loading of new filters, then tends to trail off as the loading increases. *Percent Increase in Pressure Drop Average HEPA Filter Life in Years 50% 3 Years ** 100% 5 Years 180% 7 Years *** 250% 10 Years * Percent increase testing based on NSF/ANSI 49, Annex A.12 motor blower performance test methods ** Base line NSF requirement assuming more capacity is available *** Industry standard requirement based originally on designed usage of AC PSC motor NEW Energy Efficient Motor Technology AC PSC versus New Motor Technologies New motor technologies are being designed into most BSC s today primarily as a way to reduce energy consumption. AC 3-phase, DC ECM and DC motors are being used into cabinets today, these technologies offer increased energy efficiency ranging from 40% to 80%. However, most all of these new motor technologies don t provide the older AC PSC motor technology inherent capabilities to increase rpm (torque) with greater filter loading [resistance]. Instead, these new motors must be used with an airflow feedback loop control system or a motor feedback control system. Both methods are valid and provide adequate airflow control to keep the cabinets airflow within the recommended airflow containment performance range. 5

Utilizing these new motor technologies with the necessary control capability can reduce the designed filter load capacity of the system and still meet the NSF requirement for motor / blower performance. In other words, the original requirement of the NSF standard didn t allow the fan (motor) speed control to be changed making sure the AC PSC motor was sized correctly with the fan using its inherent capability to increase rpm (torque) with more resistance or filter loading. The new energy efficient motors require the use of an integrated control system to increase rpm (speed) to compensate for HEPA filter loading. The NSF standard does not restrict usage of a control system or place additional requirements with its use. The standard today, still only requires that the total air delivery shall fall off no more that 10% as a result of 50% increase in the pressure drop across the filter. The additional capacity of 180% that was virtually guaranteed with the use of an AC PSC motor may not be present anymore, unless the product specifications for the BSC indicate the requirement or manufacturer provides this information within the specifications of the BSC. Advantages of DC ECM Motor Technology The DC ECM new motor technology actually increased the filter loading capability. The DC ECM motor was optimally incorporated and implemented with a specific forward curved fan for each width/volumetric size of cabinet. The DC ECM motor design provides additional capacity in terms of motor rpm that provides a 250% increase in pressure drop or static pressure filter loading capacity. In addition to the increased filter load capacity, energy costs have been reduced by 50 % and the system is quieter in terms of noise and vibration. The DC ECM motor, when properly designed and engineered into the BSC, provides the lowest life cycle cost in terms of energy, filter load capacity and reliability. Other Considerations: Size and Type of Supply and Exhaust Filters HEPA Filters HEPA Filters retain or trap only particulates. [To learn more, see NuAire Technical Bulletin entitled Use of HEPA Filters in Biological Safety Cabinets ] Chemicals, fumes, gases, and vapors penetrate through the HEPA Filter Media. As with any media-type filter, the surface area or the size of the filter and the number of air exchanges through the filter will ultimately determine how effective the filter is at retaining particles. 6

ULPA Filters ULPA Filters create more resistance in the airflow dynamics of the cabinet, requiring a larger blower or multiple blowers to maintain proper airflows. ULPA filters cost more, contain additional dense fiberglass media and must be replaced more often than a HEPA filter. For biological applications, there is no gain in using a ULPA filter compared to a HEPA filter. [See Technical Bulletin] Controlling Airflow Exhaust Choke/Damper HEPA filter life can further be extended with use of an exhaust choke or damper. Uniform Air Pressure within the Positive Pressure Plenum Creating an even pressure within this chamber allows the filter to load at a very even rate with particulates. Electronic Airflow Control System [Motor Speed Controller] Even though the DC ECM motor offers greater horse power and uses an integrated digital control system the use of an electronic motor speed controller allows the air flow to be fined tuned for additional HEPA life. The Exciting Advantages of using NuAire NuAire incorporates the best of our existing technology and the best of the new DC ECM technology to give you a better Value, Lower energy costs, longer filter life, and reduced noise and vibration. NuAire uses the largest HEPA filters with the most pleats per square inch; an electronic airflow control system; internal exhaust damper; and individually selected, optimally determined forward-curved fans for each model size/width. We are the only manufacturer to give these features insuring you the best performance, quality, reliability, service and cost saving technologies. 7

more under the hood [ Over 100,000 Located Worldwide ] Class II Biological Safety Cabinets Save 40% off your total operating costs over a 15 year lifetime of your biological safety cabinet. Experience increased user ergonomics. Superior construction improves user, product, and environmental safety. HEPEX Zero Leak Airflow system ensures correct filter loading and true laminar airflow. Three models provide your choice of Control Systems TouchLink FlowGard Essentials 0.5 1.0 1.5 2.0 Have a smartphone? Check out the CellGard ES video presentation. 1. Open a barcode scanner application on your Smartphone (such as neoreader, Mobiletag, ScanLife, etc.) 2. Point your phones camera at the code and scan 3. The code will bring you to a mobile site where you can find out more information about NuAire CellGard, right from your Smartphone! US & CA year warranty 2011 NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com

Process 9-1204P Rev. 2 5/11 For more information please visit www.nuaire.com or call 1.800.328.3352