Wiring diagrams. Compact NSX. Contents



Similar documents
Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Masterpact NW Circuit breakers and switch-disconnectors from 800 to 6300 A

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

more than a breaker it s a breakthrough Compact NSX

Low voltage electrical distribution. Electronic trip units. User manual 09/2009

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

SENTRON Switching and Protection Devices Air Circuit Breakers

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

Inwall 4 Input / 4 Output Module

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

IZM ACB/Circuit-breakers. Robust safety. Extract from Main Catalogue HPL2010 IZM26 Circuit-breakers IN26 Switch-disconnectors

Cam switches. Page. Overview 4-2. ON-OFF switches, main switches, maintenance switches 4-3. Changeover switches, reversing switches 4-5

PCS0100en Persy Control Services B.V. Netherlands

Circuit Breakers. Next Generation of Protection Capabilities

Motor circuit-breakers

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Device Support in PowerLogic ION Enterprise 5.6 Service Pack 2

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Modular I/O System Analog and Digital Interface Modules

ICON Server box installation manual Rev. 1.1

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Pilot-wire differential relay for lines with two or more terminals

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Plug and Socket Devices CES 63 A Series 8579

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

mecotron Safety relay ESTOP-2 For emergency stop monitoring

R.C.C.B. s two-pole LEXIC

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Compact, Interpact and Masterpact. Source changeover system. Catalogue 2007

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Thermal-Magnetic Circuit Breaker M1-..

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

CAN BUS INTERFACE. Module Information

3PH2 or 3PHE 3 Phase Control Board

instabus KNX / EIB System System E F G H

Permissible ambient temperature Operation Storage, transport

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

Electronic overload relay EF65, EF96 and EF146

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Sentron Series Circuit Breakers

PROTECT. Safety Relay Modules PROTECT-SRB s Catalogue Protect/04

is then retained absolutely without interruption.

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Electric Rotary Actuator - On/Off or programmable control actuator

Safety Relays ESM/ESM-F

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Install the DeviceNet Module using the following procedure:

Voltage Regulator SPAU 341 C. Product Guide

SYSTEM 4C. C R H Electronics Design

CONFIGURABLE SAFETY RELAYS

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Power Generation. Power Control PCL System Generator Set Control

Instruction Bulletin. Hand-held Test Kit. for Micrologic Series 2.0 and Above Trip Units and Compact NS Circuit Breakers Equipped with STR Trip Units

Product and functional description

Product Specification

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Plug and Socket Devices SolConeX 16 A Series 8570

Electronic overload relay EF19 and EF45

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Merlin Gerin Multi 9 System Protection Miniature Circuit Breakers

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

MAKING MODERN LIVING POSSIBLE. Wiring Diagram DHP-R.

INSTALLATION MANUAL XM3 Reader

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Current and voltage measuring relays

SYSTEM 45. C R H Electronics Design

ACS-30-EU-EMDR-10-MOD

Safety automation solutions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PSR The compact range Description

Quick Connect. quick - simple - efficient.

Charge Controller CC611/CC612 Preliminary datasheet

Tmax MCCBs. Molded case circuit breakers. Tmax

Kit Watt Audio Amplifier

LOXONE 12 Channel Amplifier

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

FIREDEX Conventional Fire Panels

500r+ Installation and User Guide

Arc Protection Relay REA 101. Operator s Manual

Programming A PLC. Standard Instructions

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Reverse-feed applications for circuit breakers

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

Transcription:

Compact NSX Wiring diagrams Contents Functions and characteristics A-1 nstallation recommendations B-1 Dimensions and connection C-1 Compact NSX100 to 630 Fixed circuit breakers D-2 Plug-in / withdrawable circuit breakers D-4 Motor mechanism D-6 SDx module with Micrologic D-8 SDTAM module with Micrologic M D-9 Additional characteristics E-1 Catalogue numbers F-1 Glossary G-1 559E4000.indd version: 1.0 D-1

+ - + - Wiring diagrams Compact NSX100 to 630 Fixed circuit breakers Power Micrologic Remote operation Upstream CB DB115707 3P or 4P N L2 L3 BPO BPF H L D2 C2 MN MX ou U D1 C1 3P + N N L2 L3 Downstream CB Motor mechanism (MT) a (220/240 V) HL BSCM U EN ENCT H2 H1 Communicating motor mechanism (MTc) a Micrologic A or E A/E Communication H(), L(BL): data - (), + (): 24 V DC power supply A/E ZS (Zone Selective nterlocking) : ZS OUT SOURCE : ZS OUT : ZS N SOURCE : ZS N ST (short time) : ZS N GF (ground fault) Note:,, for NSX400/630 only. A/E E ENCT: external neutral current transformer: - shielded cable with 1 twisted pair (, ) - shielding earthed at one end only (CT end). Connection L = 30 cm max. - maximum length of 10 metres - cable size 0.4 to 1.5 mm 2 - recommended cable: Belden 41 or equivalent. EN: external neutral voltage tap for connection to the neutral via a 3P circuit breaker. Remote operation MN: undervoltage release or MX: shunt release Motor mechanism (MT) : opening order : closing order, : power supply to motor mechanism : al position () : interlocking (mandatory for correct operation) BPO: BPF: opening pushbutton closing pushbutton Communicating motor mechanism (MTc), : motor mechanism power supply BSCM: breaker status and control module D-2 version: 2.0 559E4100.indd

ndication contacts DB115708 Closed Closed OF4 41 42 44 OF3 31 21 32 34 22 24 OF2 OF1 11 12 14 SD 91 92 94 CAF2 CAF1 131 121 101 134 124 102 104 CAO1 SDV 71 72 74 Terminals shown in red O must be connected by the customer. ndication contacts OF2 / OF1: device ON/OFF indication contacts OF4 / OF3: device ON/OFF indication contacts (NSX400/630) : fault-trip indication contact (short-circuit, overload, ground fault, earth leakage) SD: trip-indication contact CAF2/CAF1: early-make contact (rotary handle only) CAO1: early-break contact (rotary handle only) SDV: earth leakage fault trip indication contact (add-on Vigi module) Colour code for auxiliary wiring : red : violet : white : grey : yellow OR: orange : black BL: blue : green 559E4100.indd version: 2.0 D-3

+ - Wiring diagrams Compact NSX100 to 630 Plug-in / withdrawable circuit breakers Power Micrologic Remote operation Upstream CB DB115709 3P or 4P N L2 L3 BPO BPF BL - + L H 24/34 22/32 D2 BL C2 OR OR BL D2 C2 MN MX or D1 C1 D1/C1 3P + N N L2 L3 HL a (220/240 V) 41 42 44 U Motor mechanism (MT) Downstream BSCM U EN ENCT H2 OR H1 a Communicating motor mechanism (MTc) D-4 version: 2.0 559E4100.indd

ndication contacts Carriage switches DB115710 Closed Closed Connected Disconnected OF4 41 42 44 OF3 31 21 32 34 22 24 OF2 OF1 11 12 14 SD 91 121 92 94 CAF2 CAF1 131 101 134 124 102 104 314 312 352 354 CAO1 SDV CE CD 41 31 21 11 91 71 71 311 351 72 74 42 44 32 34 22 24 12 14 92 94 72 74 Micrologic A or E A/E Communication H(), L(BL): data - (), + (): 24 V DC power supply A/E ZS (Zone Selective nterlocking) : ZS OUT SOURCE : ZS OUT : ZS N SOURCE : ZS N ST (short time) : ZS N GF (ground fault) A/E E Note:,, for NSX400/630 only. ENCT: external neutral current transformer: - shielded cable with 1 twisted pair (, ) - shielding earthed at one end only (CT end). Connection L = 30 cm max. - maximum length of 10 metres - cable size 0.4 to 1.5 mm 2 - recommended cable: Belden 41 or equivalent. EN: external neutral voltage tap for connection to the neutral via a 3P circuit breaker. Colour code for auxiliary wiring : red : violet : white : grey : yellow OR: orange : black BL: blue : green Terminals shown in red v / O must be connected by the customer. Remote operation MN: undervoltage release or MX: shunt release Motor mechanism (MT) : opening order : closing order, : motor mechanism power supply : al position () : interlocking (mandatory for matic or remote recharging) BPO: opening pushbutton BPF: closing pushbutton Communicating motor mechanism (MTc), : motor mechanism power supply BSCM: breaker status and control module ndication contacts OF2 / OF1: device ON/OFF indication contacts OF4 / OF3: device ON/OFF indication contacts (NSX400/630) : fault-trip indication contact (short-circuit, overload, ground fault, earth leakage) SD: trip-indication contact CAF2/CAF1: early-make contact (rotary handle only) CAO1: early-break contact (rotary handle only) SDV: earth leakage fault trip indication contact (add-on Vigi module) 559E4100.indd version: 2.0 D-5

Wiring diagrams Compact NSX100 to 630 Motor mechanism DB114666 Motor mechanism (MT) with matic reset After tripping initiated by the "Push to trip" button or by the undervoltage (MN) release or the shunt (MX) release, device reset can be matic, remote or al. BPO BPF Following tripping due to an electrical fault (with an contact), reset must be carried out ally. Motor mechanism (MT) with remote reset DB114667 BPO BPF Reset Motor mechanism (MT) with al reset DB114668 BPO BPF Symbols : circuit breaker : opening order : closing order, : motor mechanism power supply : al position () : interlocking (mandatory for correct operation) BPO: opening pushbutton BPF: closing pushbutton : fault-trip indication contact (short-circuit, overload, ground fault, earth leakage) D-6 version: 2.0 559E4100.indd

+ - Communicating motor mechanism (MTc) DB114669 H L BSCM a (220/240 V) a Schematic representation of the communicating motor mechanism (MT). DB115436 DB114670 RSU screen for the communicating motor mechanism (MTc) RSU utility setup screen for the communicating motor mechanism. 220 VAC Auto Manu command OF SD Close command OF Enable matic reset SD Enable reset even if Reset command motor Close motor Reset motor Single-line diagram of communicating motor mechanism ing, closing and reset orders are transmitted via the communication network. The "Enable matic reset" and "Enable reset even if " parameters must be set using the RSU software via the screen by clicking the blue text. "Auto/" is a switch on the front of the motor mechanism. Symbols : circuit breaker, : motor mechanism power supply BSCM: breaker status and control module Terminals shown in red O must be connected by the customer. 559E4100.indd version: 2.0 D-7

Wiring diagrams Compact NSX100 to 630 SDx module with Micrologic Symbols SD1, SD3: SD2: SD4: SDx-module power supply output 1 (80 ma max.) output 2 (80 ma max.) DB115711 Connection a (+) 24 à 415 V SDx SD3 STD or output 1 SD2 PAL r or SDG or output 2 SD4 SD2 SD4 Micrologic 2 SDT - Micrologic 5 SDT or output 1 PAL r or output 2 Micrologic 6 SDT or output 1 SDG or output 2 SD1 Terminals shown in red O must be connected by the customer. a (-) Operation DB115712 > 105 % r tr at 6 r > 90 % r PAL r SDG SDT Circuit breaker trip order Circuit breaker reset : charge current PAL r: thermal overload pre-alarm SDG: ground-fault signal SDT: thermal-fault signal : circuit breaker D-8 version: 2.0 559E4100.indd

SDTAM module with Micrologic M Symbols SD1, SD3: SD2: SD4: SDTAM-module power supply thermal-fault signal output (80 ma max.) contactor-control output (80 ma max.) SD2 SD4 Micrologic 2-M SDT K Micrologic 6 E-M SDT K DB115713 Connection KM1 a (+) 24 to 415 V Manual reset SDT K SD3 SDTAM 6 8 4 10 2 12 1 14 OFF 15 Auto reset (minutes) SD2 SD4 SD1 Closing order ing order K KM1 KM1 Terminals shown in red O must be connected by the customer. a (-) Operation DB115714 > 95 % T < 95 % T Class (tr) at 7.2 r 400 ms SDT K KM1 %T 400 ms before circuit-breaker tripping order Contactor closing order %T Manual or matic reset : charge current SDT: thermal-fault signal K: auxiliary relay (e.g. RBN or RTBT relay) KM1: motor contactor : circuit breaker 559E4100.indd version: 2.0 D-9