Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:



Similar documents
Sample Analysis Design Isotope Dilution

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

Mass Spectrometry Signal Calibration for Protein Quantitation

4.2 Bias, Standards and Standardization

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Mass spectrometry. What are the principles behind MS? What do all MS instruments have in common?

Guidance for Industry

TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

ASSURING THE QUALITY OF TEST RESULTS

METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)

Standard Operation Procedure. Elemental Analysis of Solution samples with Inductively Coupled Plasma Mass Spectrometry

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Validation and Calibration. Definitions and Terminology

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

NANOCOMPOSIX'S GUIDE TO ICP-MS MEASUREMENT

Application of ICP-MS as a Tool for Environmental Monitoring. Bill Spence Environmental Market Specialist

To avoid potential inspection

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

Signal, Noise, and Detection Limits in Mass Spectrometry

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

An example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry

Quantitation of Drugs in Dried Bloodstains. Thomas Meyer Anna Gomenyuk Nadiah Lester

Introduction. The following definitions may help you better understand the components of the data report.

Elemental Analyses by ICP-AES

Ecology Quality Assurance Glossary

Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory

HS 1003 Part 2 HS 1003 Heavy Metals Test

USING CLSI GUIDELINES TO PERFORM METHOD EVALUATION STUDIES IN YOUR LABORATORY

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

Quality Assurance/Quality Control in Acid Deposition Monitoring

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Experiment 10. Radioactive Decay of 220 Rn and 232 Th Physics 2150 Experiment No. 10 University of Colorado

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

The Empirical Formula of a Compound

Lab #11: Determination of a Chemical Equilibrium Constant

Chemistry 111 Laboratory Experiment 7: Determination of Reaction Stoichiometry and Chemical Equilibrium

SPIKE RECOVERY AND DETERMINING A METHOD DETECTION LIMIT Pamela Doolittle, University of Wisconsin Madison, pssemrad@wisc.edu 2014

Colorimetric Determination of Iron in Vitamin Tablets

Dissolved and precipitated oxalate

Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories

1) Write the following as an algebraic expression using x as the variable: Triple a number subtracted from the number

How to Verify Performance Specifications

Chemistry Instrumental Analysis Lecture 1. Chem 4631

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Measurement and Calibration

TRACEABILITY. Commercially available single-element solutions are used. of Single-Element Calibration Solutions

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

How To Use The Nexion 300

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Pesticide Analysis by Mass Spectrometry

Chemical Equations & Stoichiometry

Chapter 9. Systems of Linear Equations

Assay Qualification Template for Host Cell Protein ELISA

How To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer

Regional Environmental Protection Agency- Veneto Region LABORATORY REGIONAL DEPARTMENT

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Chapter 4. Evaluating Analytical Data. When using an analytical method we make three separate evaluations of experimental error.

FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA

Algebra Cheat Sheets

METHOD 6010B INDUCTIVELY COUPLED PLASMA-ATOMIC EMISSION SPECTROMETRY

SOLUBILITY, IONIC STRENGTH AND ACTIVITY COEFFICIENTS

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

How To Use An Ionsonic Microscope

3.1 Solving Systems Using Tables and Graphs

Determining Equivalent Weight by Copper Electrolysis

WM2012 Conference, February 26 March 1, 2012, Phoenix, Arizona, USA

Temperature Scales. The metric system that we are now using includes a unit that is specific for the representation of measured temperatures.

DECISION LIMITS FOR THE CONFIRMATORY QUANTIFICATION OF THRESHOLD SUBSTANCES

DESCRIPTIVE STATISTICS. The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses.

AP Physics 1 and 2 Lab Investigations

Magruder Statistics & Data Analysis

A Beer s Law Experiment

Samples RMN Analytical Report ( ) GC/FID Analysis (RM01) Nicotine Purity

QA/QC. Standard methods in field. QA/QC in the field. QA/QC in analysis

The Determination of an Equilibrium Constant

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Real-time PCR: Understanding C t

EQUATIONS and INEQUALITIES

3.4 TEST FOR BACTERIAL ENDOTOXINS. Final text for revision of The International Pharmacopoeia

EDXRF of Used Automotive Catalytic Converters

Determination of the Mass Percentage of Copper in a Penny. Introduction

UNITS OF CONCENTRATION

Honors Chemistry: Unit 6 Test Stoichiometry PRACTICE TEST ANSWER KEY Page 1. A chemical equation. (C-4.4)

LINEAR INEQUALITIES. less than, < 2x + 5 x 3 less than or equal to, greater than, > 3x 2 x 6 greater than or equal to,

Drip Club 2540 Corporate Place, Suite B103 Monterey Park, CA 91754

Mathematics Pre-Test Sample Questions A. { 11, 7} B. { 7,0,7} C. { 7, 7} D. { 11, 11}

NITRIC OXIDE and NITROGEN DIOXIDE 6014

Solutions and Dilutions

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Transcription:

Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors: 1. potential matrix effects 2. number of samples 3. consistency of matrix across samples

Step 2 Calibration/Standard Preparation EXTERNAL CALIBRATION: Prepare a set of standard solutions to cover the expected range of analyte concentrations Fit a least squares regression line y = mx + b and calculate analyte concentration in unknowns

Step 2 Calibration/Standard Preparation 23 Na calib curve (Medium resolution) 1000000 900000 800000 700000 y = 17557x R 2 = 0.9992 600000 cps 500000 400000 300000 200000 100000 0 0.00 10.00 20.00 30.00 40.00 50.00 60.00 conc ppb

Step 2 Calibration/Standard Preparation 44 Ca calib curve (Medium resolution) 40000 35000 30000 y = 676.92x R 2 = 0.9961 25000 cps 20000 15000 10000 5000 0 0.00 10.00 20.00 30.00 40.00 50.00 60.00 conc ppb

Step 2 Calibration/Standard Preparation Advantages of External Calibration Easy to prepare Quick Widely used technique

Step 2 Calibration/Standard Preparation Disadvantages of External Calibration: Need to matrix match calibration solutions and samples If standards containing <2000 ug/ml (ppm) are being used, then preparing the standards as simple aqueous solutions using the acid matrix (5% HNO 3 ) employed for the samples is sufficient HOWEVER, if the samples contain a very high concentration of one (or more) elements, then this may not be adequate

Step 2 Calibration/Standard Preparation Preparation of External Calibration Solutions: Need to evenly space calibration concentrations If the highest concentration is much higher than the rest, linear regression introduces bias favoring the high point X = independent variable = concentration Y = dependent variable = counts/second

Standard Addition Method Aliquots of spike are added to unknown samples to increase the ion signal intensities for elements of interest Typically use at least three aliquots of sample spiked with evenly spaced amounts of analyte These spiked aliquots of sample are used to generate a calibration line and calculate the concentration in the sample

Standard Addition Method S0 = unspiked sample S1 = sample spiked with analyte at concentration x S2 = sample spiked with analyte at concentration 2x S3 = sample spiked with analyte at concentration 3x S4 = so on and so on

Standard Addition Method AMT 500000 450000 400000 350000 300000 y = 29387x + 279235 R 2 = 0.9992 Cps 250000 200000 150000 100000 50000 0 0 1 2 3 4 5 6 7 Concentration (ppb)

Standard Addition Method The concentration of the unknown solution is then determined by dividing the y-intercept value by the slope of the sample-spike mixing line. From example on previous slide, Conc. sol n = 279235 / 29387 = 9.5 ppb If the original sample was a solution, then this is the concentration of the analyte in question in the solution

Standard Addition Method If the original sample was in solid form that you digested and subsequently converted into a solution; then in order to determine the concentration of the analyte in question, you must factor in the amount of total analyte in the solution and the dry weight of the sample powder

Standard Addition Method If we continue with the same example, the solution has a concentration of 9.5 ppb, and the original volume of the unknown solution was 10 ml (g) prior to aspirating some of it into the plasma for analysis, then the total amount analyte in the solution is: = 10 g x 9.5 ng/g (ppb) = 95 ng, or = 0.095 µg If the amount of powder weighed out was 0.1 g, then the concentration of the element in question is: Conc. = 0.095 µg/0.1 g = 0.95 µg/g or ppm

Standard Addition Method This method works best if the slope of the calibration line is not too shallow This will create more uncertainty in the location of the intersection between the cps of your unknown and the calibration line

Standard Addition Method For maximum precision it s necessary that the amount of sample be the same in each aliquot Also want the amount of spike added to be the same for each aliquot Amount of spike added should be as small as possible (usually 0.1 ml to 10 ml total volume)

Standard Addition Method Ideally, the highest spike concentration should be approximately equal to the concentration of analyte in the unknown Need to have some idea of the concentration in the sample prior to analysis

Advantages: Sample Analysis Design Standard Addition Method Overcomes matrix differences More precise and accurate than external calibration Disadvantages: Requires at least three aliquots for each sample Run lengths become much longer and more preparation time is required

Isotope Dilution Most accurate and precise calibration method available Requires analyte with two stable isotopes Monoisotopic elements cannot be determined via isotope dilution Spike natural sample with enriched isotope spike of analyte

Isotope Dilution The amount of spike is selected so that the resulting ratio between spiked isotope and unspiked isotope is near unity maximizes precision Typically use the most abundant isotope as the reference -- maximizes sensitivity

Isotope Dilution Check isotope ratio in unspiked sample to determine if the natural ratio in the sample matches with the predicted ratio If not -- interference in acting on one or both of the isotopes Always attempt to use interference free isotopes

Isotope Dilution Prepare the spike to desired concentration Add spike as early as possible after equilibration of spike and sample you don t have to have complete sample recovery During any stage of the process complete equilibration is absolutely necessary

Isotope Dilution Analyze the solution on the ICP using many repetitive scans (to maximize precision) Need to measure isotopic ratios on standards of a known ratio in order to correct for machine mass discrimination Use previous equation to calculate concentrations!

Advantages: Sample Analysis Design Isotope Dilution Most accurate and precise method for quantitative elemental concentrations Partial loss of analyte during preparation is compensated for since physical and chemical interferences are not an issue -- will cancel out as they will affect each isotope identically Ideal form of internal standardization since another isotope of the same element is used in this capacity

Isotope Dilution Disadvantages: Generally only applicable to multiple-isotopic elements Need an enriched isotope spike for the analyte of interest - not always available or sometimes at very high cost Need two interference free isotopes VERY time consuming

Sample Analysis Design STEP 3 INTERNAL STANDARDIZATION & INSTRUMENT DRIFT CORRECTION

Internal Standard Every sample should be analyzed with an internal standard (IS) What is an internal standard (IS)? element that is added to EVERY sample/ blank/calibration standard/qa sample/etc., that is not expected to be in the sample in appreciable quantities and is not an element of interest use IS to monitor machine drift (both short and long term) and matrix effects

Internal Standard Choice of IS depends upon which elements you are quantifying The IS should have similar properties in the plasma as element(s) of interest ICP-MS: similar in mass/ionization potential

Example: Sample Analysis Design Internal Standard attempting to quantify U - use Th attempting to quantify most transition metals - use As attempting to quantify REEs - use Re 115 In and 103 Rh are common IS for general use alternatively, you can add several IS to each sample

Internal Standard From previous slide, we assume that samples have little or no Th, As, or Re It s important to have an idea of what s in your sample prior to quantitative analysis Solid samples can use a naturally occurring element as IS, provided that you know the concentration in each sample

Procedure for IS use: Sample Analysis Design Internal Standard Calculate the concentration of the IS in each centrifuge tube the latter will contain an aliquot of your sample and an aliquot of the IS Divide the measured ion signal (CPS) by the concentration of your IS to derive the factor = CPS/ppb Divide CPS/ppb of each tube by the CPS/ppb for those measured for the blanks since these are not influenced by possible effects due to sample matrices The latter yields a dimensionless correction factor (I refer to it as a normalization factor) Use correction factor to adjust analyte counts for drift or matrix effects

Advantages: Sample Analysis Design Internal Standard Fluctuations are monitored in each sample/ calibration / blank Disadvantages: Assume that behavior of IS is the same as the analyte

Instrumental Drift Correct for instrument drift with: Internal standardization is a common procedure Use of drift corrector solutions (DCS)

Instrumental Drift Drift Corrector Solutions (DCS): Measure the same solution intermittently throughout the course of the analytical session Change in ion signal is assumed to be linear between each DCS measurement

Instrumental Drift The DCS should contain all elements of interest and can be matrix matched to samples Example: use standard reference materials (SRMs) for DCS

Instrumental Drift Apply a linear correction to samples between DCS solutions DCS 1 + ((DCS 2 - DCS 1 )*F) F = position dependent fraction

Instrumental Drift Advantages of DCS correction: all analytes are monitored for drift nothing added to sample solutions Disadvantages of DCS correction: assume change is linear cannot easily monitor matrix effects

Background & blanks Standard blank - blank used to monitor polyatomic ion interferences, gas peaks, and contamination from reagents; used for background subtraction Procedural blank - blank used to monitor contamination acquired during all stages of sample preparation; grinding, digestion, acidification, powdering, etc

Background & blanks Use of blanks during an analytical session: ALWAYS begin an analytical session with at least one standard blank Analyze standard blanks periodically throughout the course of the session in particular to monitor memory effects Process and analyze at least one procedural blank at some point during your research study; for its analysis, it s preferable to measure it early in order to avoid any potential memory effects

Background & blanks The more standard blanks that are run during an analytical session, the more information you will have with regards to monitoring change(s) in background levels throughout the entire session

Background & blanks How to determine the background : 1. just use the first standard blank 2. average all standard blanks 3. take median of all standard blanks 4. apply statistical analysis to standard blanks and select some of them

Outlier tests: Sample Analysis Design Background & blanks 1. I know the truth 2. Looks different 3. Statistical proof

Background & blanks Option 1 should be avoided - unscientific and invalid Option 2 is better but only if the measurement is repeated Option 3 is the best approach, but needs to be carried out carefully in order to avoid false negatives and positives

Background & blanks Huber Outlier Test take median of all values calculate absolute deviation x i -x m take mean of absolute deviations (MAD) multiply MAD by coefficient (k = 3-5) anything higher than k*mad is rejected as outlier

Background & blanks Calculation of Limit of Detection (DL) and Limit of Quantification (QL) Easy way: LOD = 3*STDEV blank ; LOQ = 10*STDEV blank

SUMMARY A good analytical method will: 1. provide the means to calculate an accurate background level 2. allow for correction of instrument drift 3. use Internal standardization to monitor matrix effects 4. provide some method for monitoring/ correcting interferences 5. Use a proper calibration strategy

Example Calculation Determination of Ca and Na in beetle blood Using External Calibration Method