Evaluating Laboratory Data. Tom Frick Environmental Assessment Section Bureau of Laboratories
|
|
|
- Joella Manning
- 10 years ago
- Views:
Transcription
1 Evaluating Laboratory Data Tom Frick Environmental Assessment Section Bureau of Laboratories
2 Overview of Presentation Lab operations review QA requirements MDLs/ PQLs
3 Why do we sample? Protect physical, chemical, and biological integrity (Clean Water Act) Water quality standards, FAC Permit compliance Interpret biological community results
4 How Do You Measure an Collect sample Prepare sample Analyte? Calibrate equipment Measure analyte Compare analyte measurement to known standard Run Quality Control samples
5 Proper location Correct equipment or bottles Prevent contamination Proper preservation
6 Sample log-in & tracking (1000 s per day) Preparation steps Holding times Pairing sample with result and QC elements
7 Calibration & maintenance Blank contamination Spike recovery Detection limits Statistically, QC failures occur routinely
8 Bottom Line on Lab Measurements Literally 1000 s of different methods to measure various types of analytes. Each method has specific quality control requirements to assure valid measurements.
9 Required Laboratory Quality Control Activities
10 QA Requirements for Laboratories, Rule NELAC Certification Performance Test Samples Mandatory Quality Control Ethics and training Reporting Location, methods, QA elements (extensive list) Audits Lab, field, document review, corrective action Data validation Completeness, data integrity & usability
11 Performance Test Samples NELAC required Blind sample, lab does not know concentration of analyte. Lab runs PT sample using routine procedures. Must achieve acceptable result in 2 of 3 previous PTs. Unknown Result must be within range
12 Instrument Response Calibration Establishing a relationship between instrument response and known concentrations. Regression line R 2 should be or better Concentration
13 Continuing Calibration Verification Instrument Response Calibration must be rechecked every 20 samples. Real value = 1.0 ug/l Usually required to be + or 5 to 15%. Concentration 0.99 ug/l
14 Lab Blank Analyte-free water processed as routine sample. Result evaluated to determine sources of internal lab contamination. Analyte-free water Result evaluated, should be U
15 Accuracy and Precision Accuracy: The ability to measure the true value. True value is NIST standard Precision: Consistency of Measurements.
16 Lab Control Sample (LCS) A known concentration of analyte added Sample processed routinely. Determine if amount detected matches amount added (+ or acceptable %). Add known Amount (spike) Determine % recovery Acceptance criteria is usually 80% to 120%
17 Lab Control Sample Duplicate Add known amount Split Compare results, determine precision
18 Why Quality Control Samples are Important Good precision, Good accuracy Good precision, Poor accuracy Poor precision, Good accuracy Poor precision, Poor accuracy
19 Accuracy The true or standard value is based on the central tendency of measurements involving multiple high quality testing laboratories, using exacting NIST procedures. Other laboratories purchase standards for calibration and QC. 1.0 ug/l
20 Precision The relative agreement in values from repeated measures of the same sample (relative standard deviation) during routine testing runs (measurement repeatability). Tight, acceptable precision Noisy, unacceptable precision
21 To Ensure the Correct Decision: DEP must verify that data are useable. Consistent with Data Quality Objectives and program requirements. We have Statutory Authority to reject data!!!
22 Data Quality & DEP If real result is higher than reported Environment is not protected If real result is lower than reported Costly, unneeded treatment requirements In either case: Legal challenges Adverse publicity Ultimately Results in More Staff Time and $$
23 Detection and Quantitation Limit Concepts
24 Definitions Minimum Detection Limit: The minimum concentration that can be measured with 99% confidence that the analyte concentration is greater than zero. Practical Quantitation Limit: The lowest level of measurement that can be reliably achieved during routine laboratory operating conditions within specified limits of precision and accuracy.
25 Radio Tower MDL/PQL Radio Reception Analogy Whole sentences, complete comprehension > PQL A few words, but no meaning = MDL Static Only: < MDL I, M U,T
26 Simplified MDL Study Take analyte free water or low level spikes and place in 7 containers Process as normal samples All prep steps, reagents, instrument calibration, etc. are routine Generate results Calculate standard deviation of results MDL is 3 times this SD This is the 99% confidence limit that you can distinguish signal from noise
27 Theoretical Probability Distributions Analytical Noise 0.4 Noise Distribution MDL set to exclude 99% of the Noise Distribution 0.3 Frequency 0.2 MDL Standard Deviations
28 MDL for More Sensitive Method MDL for Less Sensitive Method
29 Method 1631 MDL by 40 CFR Method Mercury ( n g /L ) January - March
30 MDL/PQL Relationship Concentration Present Absent 0 M I U T Region of known precision and accuracy PQL (4 x MDL) = 4 x 0.3 = 1.2 ug/l Region of high uncertainty for quantitation (greater certainty as PQL is approached) MDL (3 x SD) = 3 x.1 = 0.3 ug/l Use MDL as an Estimate of a Lab s Ability to Detect (not quantitate) at the MDL concentration
31 POSSIBLE DECISIONS Detected TRUE SITUATION Analyte Present CORRECT DECISION Analyte Not Present INCORRECT DECISION FALSE POSITIVE (Type I error) Not Detected INCORRECT DECISION FALSE NEGATIVE (Type II error) CORRECT DECISION
32 Detection Limit Values U Values > Permit Limits? Method may not be appropriate; Use more sensitive method (if available) Matrix interference or dilution may contribute to an elevated detection limit I or M Values Near Permit Limits Compliance Issue? May Require Additional Testing to Resolve
33 FAC PQL, MDL and Compliance Refers to checklist of DEP approved MDLs Results > PQL are reported as measured Results < PQL and > MDL shall be deemed as = to the MDL Results < MDL shall be reported as non-detects ( U )
34 Co Co ncentrati ncentrati on on Interpreting FAC: Examples Result Permit Limit PQL Permit Limit Result PQL MDL MDL Non- Compliance Compliance
35 Concentr Concentr ation ation Interpreting FAC: Examples PQL Result Permit Limit MDL Compliance (Results < PQL are deemed = MDL) PQL Permit Limit Result MDL Compliance
36 Concentr Concentr ation ation Interpreting FAC: Examples PQL Result MDL Permit Limit PQL Result is Non-detect MDL Permit Limit Non-Compliance Compliance
37 Tom Frick (850) Quality of Science enewsletter
APPENDIX N. Data Validation Using Data Descriptors
APPENDIX N Data Validation Using Data Descriptors Data validation is often defined by six data descriptors: 1) reports to decision maker 2) documentation 3) data sources 4) analytical method and detection
ASSURING THE QUALITY OF TEST RESULTS
Page 1 of 12 Sections Included in this Document and Change History 1. Purpose 2. Scope 3. Responsibilities 4. Background 5. References 6. Procedure/(6. B changed Division of Field Science and DFS to Office
QUALITY ASSURANCE / QUALITY CONTROL POLICY BREG SOIL AND WATER QUALITY LABORATORY UNIVERSITY OF DELAWARE
QUALITY ASSURANCE / QUALITY CONTROL POLICY BREG SOIL AND WATER QUALITY LABORATORY UNIVERSITY OF DELAWARE Department of Bioresources Engineering Rm 111 Worrilow Hall 531 S. College Ave. Newark, DE 19716-2140
1 Quality Assurance and Quality Control Project Plan
1 Quality Assurance and Quality Control Project Plan The purpose of this section is to describe the quality assurance/quality control program that will be used during the system specific field testing
Ecology Quality Assurance Glossary
Ecology Quality Assurance Glossary Edited by William Kammin, Ecology Quality Assurance Officer Accreditation - A certification process for laboratories, designed to evaluate and document a lab s ability
Data Quality. Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program
Data Quality Tips for getting it, keeping it, proving it! Central Coast Ambient Monitoring Program Why do we care? Program goals are key what do you want to do with the data? Data utility increases directly
Medical Cannabis Laboratory Approval Program
Medical Cannabis Laboratory Approval Program Application Process and Required Documentation After the publication of the Medical Cannabis Laboratory Application, currently expected by February 16, 2015,
APPENDIX 7-B SUGGESTED OUTLINE OF A QUALITY ASSURANCE PROJECT PLAN
APPENDIX 7-B SUGGESTED OUTLINE OF A QUALITY ASSURANCE PROJECT PLAN This outline is recommended for use by UST consultants/contractors in preparing a generic Quality Assurance Project Plan (QAPP) for use
American Association for Laboratory Accreditation
Page 1 of 12 The examples provided are intended to demonstrate ways to implement the A2LA policies for the estimation of measurement uncertainty for methods that use counting for determining the number
STANDARD OPERATING PROCEDURES
PAGE: 1 of 33 CONTENTS 1.0 SCOPE AND APPLICATION 2.0 METHOD SUMMARY 3.0 SAMPLE PRESERVATION, CONTAINERS, HANDLING, AND STORAGE 4.0 INTERFERENCES AND POTENTIAL PROBLEMS 5.0 EQUIPMENT/APPARATUS 6.0 REAGENTS
DATA QUALITY OBJECTIVES
The Wastewater Treatment Plant Operators Guide to Biosolids Sampling Plans CHAPTER 5 DATA QUALITY OBJECTIVES Goals of the Sampling Plan ESSENTIAL ELEMENTS OF A SAMPLING PLAN Description of the Facility
Pace Analytical e-report
Date Issued: July 28, 2014 Pace Analytical e-report Report prepared for: ATLANTIC TESTING LABORATORIES, LTD 22 CORPORATE DR CLIFTON PARK, NY 12065 CONTACT: Derek Converse ----------------------------------------------
FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA
FOOD FOR THOUGHT Topical Insights from our Subject Matter Experts UNDERSTANDING WHAT IS NEEDED TO PRODUCE QUALITY DATA The NFL White Paper Series Volume 7, January 2013 Overview and a Scenario With so
ANALYTICAL DETECTION LIMIT GUIDANCE. & Laboratory Guide for Determining Method Detection Limits
ANALYTICAL DETECTION LIMIT GUIDANCE & Laboratory Guide for Determining Method Detection Limits Wisconsin Department of Natural Resources Laboratory Certification Program April 1996 PUBL-TS-056-96 introduction
Validation and Calibration. Definitions and Terminology
Validation and Calibration Definitions and Terminology ACCEPTANCE CRITERIA: The specifications and acceptance/rejection criteria, such as acceptable quality level and unacceptable quality level, with an
CHAPTER ONE TABLE OF CONTENTS 1.0 INTRODUCTION... 1
CHAPTER ONE TABLE OF CONTENTS Section Page 1.0 INTRODUCTION... 1 2.0 QA PROJECT PLAN... 1 2.1 DATA QUALITY OBJECTIVES... 2 2.2 PROJECT OBJECTIVES... 2 2.3 SAMPLE COLLECTION... 3 2.4 ANALYSIS AND TESTING...
How to Verify Performance Specifications
How to Verify Performance Specifications VERIFICATION OF PERFORMANCE SPECIFICATIONS In 2003, the Centers for Medicare and Medicaid Services (CMS) updated the CLIA 88 regulations. As a result of the updated
Guidelines for Quality Assurance and Quality Control in Surface Water Quality Programs in Alberta
Guidelines for Quality Assurance and Quality Control in Surface Water Quality Programs in Guidelines for Quality Assurance and Quality Control in Surface Water Quality Programs in Prepared by: Patricia
Content Sheet 7-1: Overview of Quality Control for Quantitative Tests
Content Sheet 7-1: Overview of Quality Control for Quantitative Tests Role in quality management system Quality Control (QC) is a component of process control, and is a major element of the quality management
Procedure for Writing Technical Procedures
Procedure for Writing Technical Procedures 1.0 Purpose This procedure specifies when a technical procedure is needed and outlines the required elements for writing the technical procedure. 2.0 Scope This
Building Credibility: Quality Assurance & Quality Control for Volunteer Monitoring Programs
Building Credibility: Quality Assurance & Quality Control for Volunteer Monitoring Programs Elizabeth Herron URI Watershed Watch/ National Facilitation of CSREES Volunteer Monitoring Ingrid Harrald Cook
Determination of Total Suspended Solids (TSS) and Total Volatile Solids (TVS) in Waters of Fresh/Estuarine/Coastal Waters
Determination of Total Suspended Solids (TSS) and Total Volatile Solids (TVS) in Waters of Fresh/Estuarine/Coastal Waters 1. SCOPE and APPLICATION 1.1 Gravimetric analysis is used to determine total suspended
Introduction. The following definitions may help you better understand the components of the data report.
Introduction This document is designed to help our clients understand the quality control requirements and limitations of data reporting. There are three sections to this document. The first section will
Quality Assurance/Quality Control in Acid Deposition Monitoring
Quality Assurance/Quality Control in Acid Deposition Monitoring Acid Deposition and Oxidant Research Center (Network Center of EANET) Introduction Wet deposition data are used for -assessments of spatial
DATA VALIDATION STANDARD OPERATING PROCEDURES FOR CONTRACT LABORATORY PROGRAM ROUTINE ANALYTICAL SERVICES
DATA VALIDATION STANDARD OPERATING PROCEDURES FOR CONTRACT LABORATORY PROGRAM ROUTINE ANALYTICAL SERVICES UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION IV SCIENCE AND ECOSYSTEM SUPPORT DIVISION
Laboratory Quality Assurance Manual
Laboratory Quality Assurance Manual (Revision 8) Effective Date: 03/22/2013 Approved By: Randall Warden President (260) 483-4759 03/22/2013 Date Greg Neyman Vice-President (260) 483-4759 03/22/2013 Date
Approvals [Signature On File]
Page 1 of 7 Minimum Reporting Requirements for Analytical Data (Chemistry) for the Water Quality Planning Bureau Approvals SOP WQPBDMS-010 Prepared by: Chris Shirley, QA Officer, WQPB Michael Pipp, Environmental
P07 CALA Application of Requirements in ISO/IEC 17025:2005 Revision 3.4 April 9, 2014
P07 CALA Application of Requirements in ISO/IEC 17025:2005 Revision 3.4 April 9, 2014 1 TABLE OF CONTENTS FOREWORD... 1 1.0 SCOPE... 1 1.5 Safety Requirements... 1 4.0 MANAGEMENT REQUIREMENTS... 1 4.1
Proficiency Testing In A Global Analytical Environment Benefits & Challenges. AOAC September 2007
Proficiency Testing In A Global Analytical Environment Benefits & Challenges AOAC September 2007 1 The Coca-Cola Company The Coca-Cola Company is the largest manufacturer, distributor and marketer of nonalcoholic
Control Charts and Trend Analysis for ISO 17025. Speakers: New York State Food Laboratory s Quality Assurance Team
Control Charts and Trend Analysis for ISO 17025 Speakers: New York State Food Laboratory s Quality Assurance Team 1 ISO 17025 Requirements, 5.9.1: The laboratory shall have quality control procedures for
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry
Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry BY GHULAM A. SHABIR Introduction Methods Validation: Establishing documented evidence that provides a high
Developing Quality Assurance Project Plans using Data Quality Objectives and other planning tools. Developing QAPPs 5/10/2012 1
Developing Quality Assurance Project Plans using Data Quality Objectives and other planning tools 1 Introductions 2 Agenda I. Developing a QAPP II. Systematic Planning using Data Quality Objectives III.
PERFORMANCE EVALUATION AUDIT CHECKLIST EXAMPLE. EIIP Volume VI
Final 7/96 APPENDIX E - PERFORMANCE EVALUATION AUDIT APPENDIX E PERFORMANCE EVALUATION AUDIT CHECKLIST EXAMPLE APPENDIX E - PERFORMANCE EVALUATION AUDIT Final 7/96 This page is intentionally left blank.
Quality Assurance (QA) & Quality Control (QC)
Quality Assurance (QA) & Quality Control (QC) In the laboratory Georges Ruta Water Quality Scientist City West Water 1 City West Water Water Supply & Sewerage Authority Melbourne Pop. >800,000 Area 580
Technical Guidance Manual for the Implementation of the Hawai`i State Contingency Plan. Interim Final SECTION 10
Technical Guidance Manual for the Implementation of the Hawai`i State Contingency Plan SECTION 10 DATA QUALITY ASSURANCE AND QUALITY CONTROL (QA/QC) Hawai`i HEER TGM 10-1 December 31, 2008 CONTENTS Acronyms
9. Quality Assurance 9.1 INTRODUCTION 9.2 FIELD SAMPLING QUALITY ASSURANCE 9.3 ANALYTICAL QUALITY ASSURANCE. 9.3.1 Internal Quality Control
9. Quality Assurance Setting The overall goal of a well-designed and well-implemented sampling and analysis program is to measure accurately what is really there. Environmental decisions are made on the
QUALITY ASSURANCE PROJECT PLAN FOR BROWNFIELDS/VOLUNTARY CLEANUP PROGRAM SITES
QUALITY ASSURANCE PROJECT PLAN FOR BROWNFIELDS/VOLUNTARY CLEANUP PROGRAM SITES Prepared by the Missouri Department of Natural Resources Division of Environmental Quality Hazardous Waste Program Brownfields/Voluntary
Method Validation/Verification. CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory
Method Validation/Verification CAP/CLIA regulated methods at Texas Department of State Health Services Laboratory References Westgard J. O.: Basic Method Validation, Westgard Quality Corporation Sarewitz
Quality Assurance Manual
Clinical Laboratory of San Bernardino, Inc. Quality Assurance Manual Clinical Laboratory of San Bernardino, Inc. 21881 Barton Road, Grand Terrace, CA 92313 Telephone (909) 825-7693 Facsimile (909) 825-7696
Rounding and Significant Figures
National Renewable Energy Laboratory Innovation for Our Energy Future A national laboratory of the U.S. Department of Energy Office of Energy Efficiency & Renewable Energy Rounding and Significant Figures
DATA QUALITY ASSESSMENT AND DATA USABILITY EVALUATION TECHNICAL GUIDANCE
New Jersey Department of Environmental Protection Site Remediation Program DATA QUALITY ASSESSMENT AND DATA USABILITY EVALUATION TECHNICAL GUIDANCE Version 1.0 April 2014 Preamble The results of analyses
APPENDIX L DATA VALIDATION REPORT
APPENDIX L DATA VALIDATION REPORT FIELD AND DATA REPORT DOWNTOWN PORTLAND SEDIMENT CHARACTERIZATION PHASE II WILLAMETTE RIVER PORTLAND, OREGON JUNE 2010 Data Validation Report Downtown Portland Sediment
Radioanalytical Data Validation Issues and Solutions
Radioanalytical Data Validation Issues and Solutions Presented by: Terry McKibbin and Kevin Harmon Validata Chemical Services, Inc. Purpose of Data Validation The Presentation is Based on this Goal for
METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF)
METHOD 9075 TEST METHOD FOR TOTAL CHLORINE IN NEW AND USED PETROLEUM PRODUCTS BY X-RAY FLUORESCENCE SPECTROMETRY (XRF) 1.0 SCOPE AND APPLICATION 1.1 This test method covers the determination of total chlorine
1. PURPOSE To provide a written procedure for laboratory proficiency testing requirements and reporting.
Document #: FDPD-QMS.024.003 Page 1 of 12 Table of Contents 1. Purpose 2. Scope 3. Responsibility 4. References 5. Related Documents 6. Definitions 7. Safety 8. Equipment/Materials Needed 9. Process Description
Quality Assurance Plan
Page 1 of 115 Department of Environmental Conservation Laboratory UVM Hills Building D.E.C. Laboratory 105 Carrigan Drive Burlington VT 05405 Quality Assurance Plan 2015 Dan Needham March 2015 Interim
DRY CLEANING PROGRAM QUALITY ASSURANCE MANAGEMENT PLAN
DIVISION OF ENVIRONMENT QUALITY MANAGEMENT PLAN PART III: DRY CLEANING PROGRAM QUALITY ASSURANCE MANAGEMENT PLAN Revision 3 January 8, 2013 Kansas Department of Health and Environment Division of Environment
Third Party Data Validation: What you need to know and do!
Third Party Data Validation: What you need to know and do! Anand Mudambi & Pamela Wehrmann 2012 DoD EMDQ Workshop San Diego, CA Course Objectives/Outline The course will provide an overview of third party
Samples RMN070714. Analytical Report (0714-63) GC/FID Analysis (RM01) Nicotine Purity
For the benefit of VaporFi, Inc. Samples RMN070714 Analytical Report (0714-63) GC/FID Analysis (RM01) Nicotine Purity GC/MS Analysis (QG02) Anabasine, Anatabine, Myosmine, Nornicotine Enthalpy Analytical,
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850
UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850 Test Method: CPSC-CH-E1001-08.2 Standard Operating Procedure
EPA GUIDANCE FOR QUALITY ASSURANCE PROJECT PLANS EPA QA/G-5
United States Office of Research and EPA/600/R-98/018 Environmental Protection Development February 1998 Agency Washington, D.C. 20460 EPA GUIDANCE FOR QUALITY ASSURANCE PROJECT PLANS FOREWORD The U.S.
APPLICATION OF ICP-MS TECHNOLOGY FOR TRACE METALS ANALYSIS
MR. TELLIARD: Our next speaker is Paula Hogg. Paula is currently a lab manager at Hampton Roads Sanitation District s Central Environmental Laboratory. We would like to also thank Hampton Roads for sending
Analytical Data Package Reports
Analytical Data Package Reports TriMatrix offers a variety of analytical data packages formatted to meet the reporting needs and varying data quality objectives of its clients. The data packages offered
Signal, Noise, and Detection Limits in Mass Spectrometry
Signal, Noise, and Detection Limits in Mass Spectrometry Technical Note Chemical Analysis Group Authors Greg Wells, Harry Prest, and Charles William Russ IV, Agilent Technologies, Inc. 2850 Centerville
Data Quality Objectives and Quality Assurance Project
Data Quality Objectives and Quality Assurance Project Plans Quality assurance (QA) Integrated system of management procedures and activities to verify that the QC system is operating within acceptable
Commonwealth of Kentucky. Wastewater Laboratory Certification Manual
Commonwealth of Kentucky Wastewater Laboratory Certification Manual March 2013 This page intentionally left blank ii TABLE OF CONTENTS I. INTRODUCTION I-1 II. GENERAL LABORATORY REQUIREMENTS II-1 1.0 Personnel
Assay Qualification Template for Host Cell Protein ELISA
Assay Qualification Template for Host Cell Protein ELISA Introduction: With ever increasing importance being placed on host cell protein (HCP) removal during the purification process, it is critical to
Gap Analysis of ISO 15189:2012 and ISO 15189:2007 in the field of Medical Testing
Gap Analysis May 2013 Issued: May 2013 Gap Analysis of and in the field of Medical Testing Copyright National Association of Testing Authorities, Australia 2013 This publication is protected by copyright
Innovative Technology Verification Report
United States Office of Research and EPA/600-R-03/149 Environmental Protection Development May 2004 Agency Washington DC 20460 Innovative Technology Verification Report Field Measurement Technology for
Canadian Environmental Technology Verification Program Applicant Information Package CONTENTS
Canadian Environmental Technology Verification Program CONTENTS Contents... 1 Overview... 2 Performance Verification... 2 Application Information... 2 How much does verification cost?... 2 What is the
EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM. LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007)
EPA NATIONAL LEAD LABORATORY ACCREDITATION PROGRAM LABORATORY QUALITY SYSTEM REQUIREMENTS (LQSR) REVISION 3.0 (November 05, 2007) The requirements in this document apply to all lead testing laboratories
Minnesota Pollution Control Agency. Quality Assurance Project Plan Guidance
www.pca.state.mn.us Minnesota Pollution Control Agency Quality Assurance Project Plan Guidance Overview The following guidance is for use in building Quality Assurance Project Plans (QAPPs) for the Minnesota
APPENDIX C. DATA VALIDATION REPORT
APPENDIX C. DATA VALIDATION REPORT T-117 Upland Investigation Upland Investigation Data Report Appendices PROJECT NARRATIVE Basis for the Data Validation This report summarizes the results of the validation
Appendix B. Eugene/Springfield Environmental Services Laboratory Quality Assurance Plan
Appendix B Eugene/Springfield Environmental Services Laboratory Quality Assurance Plan City of Eugene NPDES Stormwater Monitoring Plan May 2011 Users of this document are responsible to ensure it is the
2010 Laboratory Accreditation Program Audioconference. Accreditation Requirements for Waived Vs. Non-waived Tests
2010 Laboratory Accreditation Program Audioconference Accreditation Requirements for Waived Vs. Non-waived Tests Objectives: After participating in this audioconference you will be able to: Define the
Glossary. Acceptable Value - An observed or corrected value that falls within the acceptable range.
GLOSSARY Acceptable Quality Range - The interval between specified upper and lower limits of a sequence of values within which the values are considered to be satisfactory. Acceptable Value - An observed
PERFORMANCE-BASED EVALUATION OF LABORATORY QUALITY SYSTEMS An Objective Tool to Identify QA Program Elements that Actually Impact Data Quality
PERFORMANCE-BASED EVALUATION OF LABORATORY QUALITY SYSTEMS An Objective Tool to Identify QA Program Elements that Actually Impact Data Quality ABSTRACT Sevdâ K Aleckson, Western Region Quality Assurance
Standard Operating Procedure for Database Operations
PM 2.5 Diltabase Operations Date: May 8 2008 Page I of 18 Standard Operating Procedure for Database Operations Environmental Health and Safety Division RTl lnternational* Research Triangle Park, North
M E M O R A N D U M. Austin Police Department Field Support Services Forensic Science Division
M E M O R A N D U M Austin Police Department Field Support Services Forensic Science Division TO: Bill Gibbens, Division Manager FROM: Tony Arnold, Quality Assurance Manager DATE: July 20, 2011 SUBJECT:
Appendix C Data Validation Report
Appendix C Data Validation Report INTRODUCTION Basis for the Data Validation This report summarizes the results of the summary (Level III) data validation performed on sediment, water, and quality control
Electronic Data Validation Using the Locus Environmental Information Management System. Tricia Walters Locus Technologies
Electronic Data Validation Using the Locus Environmental Information Management System Tricia Walters Locus Technologies Locus Technologies 2014 Agenda Introduction Environmental Information Management
Drip Club 2540 Corporate Place, Suite B103 Monterey Park, CA 91754
Drip Club 2540 Corporate Place, Suite B103 Monterey Park, CA 91754 Carbonyl Assay Samples Received 11/25/2015 Analysis Report (1115-593B) GC/MS Analysis (ENT225) Diacetyl 2,3-Pentanedione (aka Acetyl propionyl)
RTP s NUCLEAR QUALITY ASSURANCE PROGRAM
RTP s NUCLEAR QUALITY ASSURANCE PROGRAM RTP operates under one quality program, whether you purchase products that are commercial grade, nuclear safety-related or industrial safety compliant (IEC 61508).
MIDLAND AREA SOIL SAMPLING MIDLAND, MICHIGAN
QUALITY ASSURANCE PROJECT PLAN MIDLAND AREA SOIL SAMPLING MIDLAND, MICHIGAN Revised May 2013 URS Corporation 9400 Amberglen Boulevard Austin, Texas 78729 (512) 454-4797 TABLE OF CONTENTS Section 1 Objectives
Quality Assurance Plan
Page 1 of 84 Quality Assurance Plan Analytical Laboratory Services, Inc. Prepared By: Environmental Program 34 Dogwood Lane Middletown, PA 17057 Tel: (717) 944-5541 Fax: (717) 944-1430 Helen MacMinn Quality
Bryte Chemical Laboratory Quality Assurance Manual
Quality Assurance Technical Document 8 Bryte Chemical Laboratory Quality Assurance Manual May 2006 State of California The Resources Agency Department of Water Resources Bryte Chemical Laboratory Quality
CERTIFICATE OF ANALYSIS
Attention: Angela Mazza / Kathleen Wilson Catholic Education Centre 80 Sheppard Ave E North York, ON M2N 6E8 Your Project #: ANNUNCIATION Your C.O.C. #: na Report #: R3046860 Version: 1 MAXXAM JOB #: B488250
QUALITY ASSURANCE PLAN
QUALITY ASSURANCE PLAN Revision 16.0 June 2013 (Initial Version Release: January 2001) Prepared By: J. Nathan Hawley and Josh Kirkpatrick Basic Laboratory, Inc. Basic Laboratory, Inc. 2218 Railroad Avenue
Data Management Implementation Plan
Appendix 8.H Data Management Implementation Plan Prepared by Vikram Vyas CRESP-Amchitka Data Management Component 1. INTRODUCTION... 2 1.1. OBJECTIVES AND SCOPE... 2 2. DATA REPORTING CONVENTIONS... 2
Sample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:
Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors: 1. potential matrix effects 2. number of samples 3. consistency of matrix across samples Step 2 Calibration/Standard
State Meat and Poultry Inspection (MPI) Program Laboratory Quality Management System Checklist
This checklist is intended to help laboratories improve the quality of their testing programs with regard to meat and poultry testing samples, in order to ensure those laboratories are at least equal to
Drinking Water Analytical Method and Program Requirements: Roles and Responsibilities, Analytical Method Approval, and Effective Oversight
Drinking Water Analytical Method and Program Requirements: Roles and Responsibilities, Analytical Method Approval, and Effective Oversight National Environmental Monitoring Conference July 13, 2015 Daniel
COPY. Revision History: Changes were made to reflect the current practice of only including the most recent changes in the revision history.
Revision History COPY The top row of this table shows the most recent changes to this controlled document. For previous revision history information, archived versions of this document are maintained by
USE OF REFERENCE MATERIALS IN THE LABORATORY
USE OF REFERENCE MATERIALS IN THE LABORATORY What is a reference material? A general definition of a reference material is a material or substance one or more of whose property values are sufficiently
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: CONTINUOUS RADON MONITOR (CRM) by Proportional Counting. Method Number: ELAP method code 7037
LAB ID and/or LABORATORY NAME: ASSESSOR NAME: DATE: CONTINUOUS RADON MONITOR (CRM) by Proportional Counting Method Number: ELAP method code 7037 SOP Number: Revision Number: SOP Date: Personnel / Data
Laboratory Procedure Manual
Laboratory Procedure Manual Analyte: Matrix: Method: Method No.: Lead Dust Wipes Modification of the Automated AAII-25 Colorimetric method Nitric and Hydrochloric Acid Digestion followed by Atomic Absorption
Analytical Procedures and Method Validation
IPPC Discharges Monitoring Workshop Analytical Procedures and Method Validation Peter Webster Regional Chemist (EPA Cork) Contents... Overview of data quality Selection of suitable Analytical Methods Choosing
Laboratory Director Responsibilities
Clinical Laboratory Improvement Amendments (CLIA) Laboratory Director Responsibilities What Are My Responsibilities As A Laboratory Director NOTE: Congress passed the Clinical Laboratory Improvement Amendments
Quality Assurance For Environmental Laboratories
Quality Assurance for Environmental Laboratories Gary L. Johnson - U.S. EPA Raymond G. Merrill, Jr. ERG September 15, 2008 1 Session Objectives This Session will discuss: Concept of Quality for Environmental
Working Copy - 1,- / t&,1 r. Responsibilities of the Laboratory Quality Assurance Officer. EffectiveDate: 7/ltl/ l'rritials: tuwt
QAM.Q-1 13 Approval: Responsibilities of the Laboratory Quality Assurance Officer Laboratory Manager/ Quality Assurance Officer Concurrefirco - -/^/ - 1,- Rev. 4 EffectiveDate: 7/ltl/ Date,i / t&,1 r Renewat
NC SBI QUALITY ASSURANCE PROGRAM
NC SBI QUALITY ASSURANCE PROGRAM for the SBI Reviewed by: Deputy Assistant Director Bill Weis Date: Approved by: Assistant Director Jerry Richardson Date: Originating Unit: SBI Effective Date: July 25,
TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS
TEST REPORT: SIEVERS M-SERIES PERFORMANCE SPECIFICATIONS. PURPOSE The purpose of this report is to verify the performance characteristics of the Sievers M-Series TOC Analyzers. Performance was quantified