Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Type: DILM32 10(24V50HZ) Article No.:

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Bimetallic Overload Relay Specifications

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Three-phase monitoring relay CM-PFE

Manual motor starter MS116

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Catalog. Modular DIN rail components Installation contactors

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Technical catalogue. Modular DIN rail components Installation contactors

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

RM4TG20 three-phase network control relay RM4-T - range V

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Thermistor motor protection

R.C.C.B. s two-pole LEXIC

ZS25 Screw Clamp Terminal Blocks Feed-through

Safety technique. Emergency stop module BO 5988 safemaster

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

EMR measuring and monitoring relays

Manual Motor Starter MS 116 up to 16 A Technical Data

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

5SV Residual Current Protective Devices

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ZS10 Screw Clamp Terminal Block

E-STOP relays, safety gate monitors

Safety automation solutions

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Relés e Contatores de Estado Sólido SIRIUS

Pluggable interface relays CR-P Pcb relays

CompactLogix Power Supplies Specifications

Analog signal converters CC-E I/I Current / current isolators

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Series 8146/5-V37 and Series 8150/5-V37

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

PSR The compact range Description

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

Unified requirements for systems with voltages above 1 kv up to 15 kv

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Standard-compliant switchgear and controlgear production

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

HERZ-Thermal Actuators

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

SPST-NO SPDT DPST-NO DPDT

Redundancy Module QUINT-DIODE/40

Contact expander modules

Power Supplies 3. SDN-P DIN Rail Series

Thermal-Magnetic Circuit Breaker M1-..

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

D-Line Contactors, Overload Relays and Accessories

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Contact expansion modules

8146/5 Series Breaker Panelboards

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PHOENIX CONTACT Features

CQM1-SF200/CS1W-SF200

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

E-STOP relays, safety gate monitors

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Transcription:

Currenttransformer-operatedoverloadrelay,60-90A,1N/O+1N/C Partno. ZW7-90 Articleno. 002618 CatalogNo. XTOT090C3S Deliveryprogramme Product range ZW7 current transformer-operated overload relays Description Test/off button Reset pushbutton manual/auto Trip-free release Protection with heavy starting duty Mounting type Separate mounting Settingrange Overload releases I r A 60-90 Contact sequence Auxiliarycontacts N/O = Normally open 1 N/O N/C = Normally closed 1 N/C Notes The main current parameters are defined by the main current wiring which is used. Technicaldata General Standards IEC/EN 60947, VDE 0660, UL, CSA Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 Ambient temperature Open C -25 - +50 Enclosed C - 25-40 Temperature compensation Continuous Mounting position As required Weight kg 0.8 Mechanical shock resistance g 10 Sinusoidal Shock duration 10 ms Degree of Protection IP00 Protection against direct contact when actuated from front (EN 50274) Finger and back-of-hand proof Mainconductingpaths Rated impulse withstand voltage U imp V AC 8000 Overvoltage category/pollution degree III/3 Rated insulation voltage U i V 1000 Rated operational voltage U e V AC 1000 Safe isolation to EN 61140 Between auxiliary contacts and main contacts V AC 440 Between main circuits V AC 440 Short-circuit protection Maximum fuse With overload relay in conjunction with a transformer as required for the contactor Current heat loss (3 conductors) Lower value of the setting range W 3 Maximum setting W 10 Push-through opening mm 27 Auxiliaryandcontrolcircuits Rated impulse withstand voltage U imp V 4000 11/25/2015 002618 - HPL-ED2015 V17.0 EN 1 / 5

Overvoltage category/pollution degree III/3 Terminal capacities mm 2 Solid 2 mm 2 x (0.75-4) Flexible with ferrule 2 mm 2 x (0.75-2.5) Solid or stranded AWG 2 x (18-14) Terminal screw M3.5 Tightening torque Nm 0.8-1.2 Tools Pozidriv screwdriver Size 2 Standard screwdriver mm 1 x 6 Rated insulation voltage U i V AC 500 Rated operational voltage U e V AC 500 Safe isolation to EN 61140 between the auxiliary contacts V AC 240 Conventional thermal current I th A 6 Rated operational current I e A AC-15 Make contact 120 V I e A 1.5 220 V 230 V 240 V I e A 1.5 380 V 400 V 415 V I e A 0.5 500 V I e A 0.5 Break contact 120 V I e A 1.5 220 V 230 V 240 V I e A 1.5 380 V 400 V 415 V I e A 0.9 500 V I e A 0.8 DC-13 L/R - 15 ms Pilot Duty 24 V I e A 0.9 60 V I e A 0.75 110 V I e A 0.4 220 V I e A 0.2 AC operated B300 at opposite polarity B600 at same polarity DC operated R300 Short-circuit rating without welding max. fuse A gg/gl 6 Making and breaking conditions to DC-13, time constant as stated. DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 90 Heat dissipation per pole, current-dependent P vid W 2.1 Equipment heat dissipation, current-dependent P vid W 6.3 Static heat dissipation, non-current-dependent P vs W 0 Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -25 Operating ambient temperature max. C 50 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 11/25/2015 002618 - HPL-ED2015 V17.0 EN 2 / 5

10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM6.0 Low-voltage industrial components (EG000017) / Thermal overload relay (EC000106) Electric engineering, automation, process control engineering / Low-voltage switch technology / Overload protection device / Thermal overload relay (ecl@ss8.1-27-37-15-01 [AKF075011]) Adjustable current range A 60-90 Max. rated operation voltage Ue V 690 Mounting method Separate positioning Type of electrical connection of main circuit Screw connection Number of auxiliary contacts as normally closed contact 1 Number of auxiliary contacts as normally open contact 1 Number of auxiliary contacts as change-over contact 0 Release class - Approvals Product Standards UL 508; CSA-C22.2 No. 14; IEC/EN 60947-4-1; CE marking UL File No. E29184 UL Category Control No. NKCR CSA File No. 12528 CSA Class No. 3211-03 North America Certification UL listed, CSA certified Specially designed for North America No Suitable for Branch circuits Max. Voltage Rating 600 V AC Degree of Protection IEC: IP00, UL/CSA Type: - 11/25/2015 002618 - HPL-ED2015 V17.0 EN 3 / 5

Characteristics These tripping characteristics are mean values of the spread at 20 C ambient air temperature in a cold state. Tripping time depends on response current. When the devices are at operational temperature the tripping time of the overload relay reduces to approx. 25 % of the read off value. 11/25/2015 002618 - HPL-ED2015 V17.0 EN 4 / 5

Dimensions Reset/on Permissible mounting positions Additionalproductinformation(links) IL03407124Z,Trippingcharacteristics IL03407124Z, Tripping characteristics ftp://ftp.moeller.net/documentation/awa_instructions/il03407124z2010_10.pdf IL04210001Z,Overloadrelay,Currenttransformer-operatedoverloadrelay IL04210001Z, Overload relay, Current transformer-operated overload relay ftp://ftp.moeller.net/documentation/awa_instructions/il04210001z2015_03.pdf 11/25/2015 Eaton Industries GmbH http://www.eaton.eu 11/2015 by Eaton Industries GmbH 002618 - HPL-ED2015 V17.0 EN 5 / 5